MaxiMet

(.9$PNQBDU8FBUIFS4UBUJPO
The MaxiMet range of compact weather stations is designed and manufactured by Gill Instruments. MaxiMet products use
reliable, high quality instruments to provide accurate meteorological information in a wide variety of applications.

GMX501 Features
Temperature, humidity, pressure."DPNCJOFEJOTUSVNFOUNPVOUFEJOTJEFUISFF
EPVCMFMPVWFSFE OBUVSBMMZBTQJSBUFESBEJBUJPOTIJFMETXJUIOPNPWJOHQBSUT5IFSFTVMUT
BSFIJHIQFSGPSNBODFBDSPTTFBDINFBTVSFNFOUPWFSMPOHQFSJPETPGUJNF
Solar radiation. "OJOUFHSBUFETPMBSSBEJBUJPOTFOTPSQZSBOPNFUFS5IJTIJHIMZBDDVSBUF
JOTUSVNFOUVTFTBUIFSNBMTFOTPSNPVOUFEBUJUTCBTFBOEQSPUFDUFECZBTJOHMFHMBTT
EPNFUPSFDPSEUIFBNPVOUPGMJHIUJOXBUUTQFSNFUSF*UJTXJEFMZVTFEJOBHSP
NFUFPSPMPHJDBMBQQMJDBUJPOTBOEGPSNPOJUPSJOHUIFQFSGPSNBODFPGTPMBSQBOFMT
Wind. 8JOETQFFEBOEEJSFDUJPONFBTVSFNFOUTBSFQSPWJEFEWJBBOVMUSBTPOJDTFOTPS
BOEUIFBEEJUJPOPGBOFMFDUSPOJDDPNQBTTQSPWJEFTBQQBSFOUXJOENFBTVSFNFOUT
"WFSBHFTQFFEBOEEJSFDUJPOUPHFUIFSXJUI8.0BWFSBHFTBOEHVTUEBUBJTBMTP
QSPWJEFE"EE(14 PQUJPOBM
UPQSPWJEFUSVFXJOEBOEPUIFSGFBUVSFT

TEMP, HUMIDITY & PRESSURE SOLAR RADIATION WIND PARAMETERS


ƒ Air Pressure / Temperature ƒ Complies with ISO 9060 ƒ Wind speed & direction ƒ Solar radiation 8/m2
and WMO Guidelines
ƒ Relative / Absolute humidity ƒ Apparent and true wind (with GPS) ƒ Sunshine hours hrs
ƒ Output in watts per metre2
ƒ Naturally aspirated UV stable ƒ WMO wind averages and gust ƒ Temperature °C / °F / °K
radiation shield ƒ 180° hemispherical field of view
ƒ Compass ƒ Relative humidity % Rh
ƒ Records sunshine hours
ƒ Protection against wind-blown ƒ Barometric pressure hPa, Nbar, mm
precipitation/dust ƒ Integrated Hukseflux Hg *O)H
LP02 pyranometer
ƒ 8FUCVMCUFNQFSBUVSF¡$¡'¡,
ƒ Glass dome
ƒ Absolute humidity g/m3
GPS (OPTION) ƒ "JSEFOTJUZLHN
142mm
ƒ Height above sea level m ƒ Wind speed
m/s, km/hr, mph, kts, ft/min
ƒ 4VOSJTFTVOTFU
ƒ Wind direction °
43mm

ƒ 1PTJUJPOPGUIFTVO
ƒ 8JOEDIJMM¡$¡'¡,
ƒ 5XJMJHIU
ƒ True/apparent wind
ƒ 4PMBS/PPO
ƒ "OHMFPG5JMU
ƒ MSL pressure
ƒ Outputs
RS232,422, 485, SDI-12, NMEA,
MODBUS, Analogue (option)
264mm

All MaxiMet Models Feature


ƒ 2VBMJUZ.FBTVSFNFOUT ƒ 3FBM5JNF0VUQVU
ƒ -JHIUXFJHIUBOE3PCVTU ƒ &BTZ*OTUBMMBUJPO
7.5mm

ƒ -PX1PXFS.PEF ƒ (JMM$VTUPNFS4VQQPSU
ƒ 'SFFPG$IBSHF4PGUXBSF ƒ :FBS8BSSBOUZ
ƒ (JMM1SPWFO3FMJBCJMJUZ
ƒ $PNQBDU*OUFHSBUFE%FTJHO

1MFBTFTFFUIFNBOVBMGPSBGVMMMJTUPGEFSJWFEQBSBNFUFST
MaxiMet (.9$PNQBDU8FBUIFS4UBUJPO

Applications
ƒ #VJMEJOHBOE*OEVTUSJBM$POUSPMT ƒ $PBTUBM ƒ &EVDBUJPOBM
ƒ "VUIPSJUJFT ƒ "HSJDVMUVSBM ƒ $PNNFSDJBM
ƒ 5SBOTQPSU ƒ 4BGFUZ ƒ &OFSHZ

WIND SPEED DEW POINT OUTPUTS


Range 0.1 m/s to 60 m/s Range -40°C to +70°C Output rate 1/s, 1/min, 1/hr
Accuracy ± 3% to 40 m/s, Resolution 0.1 Digital Comms Serial RS232, RS422,
± 5% to 60 m/s Modes RS485, SDI-12, NMEA,
Accuracy ± 0.3°C @ 20°C
MODBUS, ASCII
Resolution m/s 0.01 Units °C, °F, °K
Analogue Outputs Available via separate
Starting 5ISFTIPME 0.1 m/s Sampling Rate 1 Hz optional device
Sampling Rate 1 Hz
Units m/s, km/hr, mph, kts, ft/min
PRESSURE POWER
Range 300 to 1100IQB Power Supply 5 to 30 Vdc
WIND DIRECTION
Resolution 0.1 hPa Power (Nominal) 25 mA continuous high
Range 0-359° 12 Vdc mode. 0. mA eco-power
Accuracy ± 0.5 hPa @ 25°C
Accuracy ± 3° to 40 m/s mode (1 hour polled)
± 5° to 60 m/s Sampling Rate 1 Hz
Units hPa, bar, mmHg, inHg
Resolution 1°
ENVIRONMENTAL CONDITIONS
Starting 5ISFTIPME 0. m/s
IP Rating 66
Sampling Rate 1 Hz GLOBAL SOLAR RADIATION
Operational -40°C to +70°C
Units Degrees Wavelength 300 to 3000 nm Temperature Range:
Sensitivity
EMC Standard: BS EN 61326-2-1:2013
Output Range 0 to 1600 8/m FCC, CFR Title 47, Part
TEMPERATURE 15, Subpart B, Class A
Resolution 1 8/m
Range -40°C to +70°C digital device
DIN Standard ISO 9060 Second Class
Resolution 0.1 CE Marking YES
Sampling Rate 1 Hz
Accuracy ± 0.3°C @ 20°C RoHS compliant YES
Units 8/m
Sampling Rate 1 Hz Weight 0.6 Kg

Units °C, °F, °K Origin UK

HUMIDITY
Range 0-100%
Resolution 1%
Accuracy ± 2% @ 20¡C (10%-90% RH)
Sampling Rate 1 Hz
Units % Rh, g/m3

Specifications may be subject to change without prior notice

Gill Instruments Limited gillinstruments.com


4BMUNBSTI1BSL (PTQPSU4USFFU *TT7
-ZNJOHUPO )BNQTIJSF40&( $PQZSJHIUª(JMM*OTUSVNFOUT9
6OJUFE,JOHEPN
5FM  

'BY  
 (JMM*OTUSVNFOUT-JNJUFE 3FH/P
DPOUBDU!HJMMJOTUSVNFOUTDPN 3FHJTUFSFE0GGJDF: Towngate House, 2-8 Parkstone Road, Poole. BH15 2PW

You might also like