Datasheet BlueSolar Charge Controller MPPT 150 45 Up To 150 100

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

BlueSolar Charge Controllers with screw- or MC4 PV connection

www.victronenergy.com
MPPT 150/45, MPPT 150/60, MPPT 150/70, MPPT 150/85, MPPT 150/100

Ultra-fast Maximum Power Point Tracking (MPPT)


Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT
controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to
10% compared to slower MPPT controllers.
Advanced Maximum Power Point Detection in case of partial shading conditions
If partial shading occurs, two or more maximum power points may be present on the power-voltage curve.
Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP.
The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP.
Outstanding conversion efficiency
No cooling fan. Maximum efficiency exceeds 98%.
Flexible charge algorithm
Fully programmable charge algorithm (see the software page on our website),
and eight pre-programmed algorithms, selectable with a rotary switch
(see manual for details).
Solar Charge Controller
MPPT 150/100-Tr Extensive electronic protection
Over-temperature protection and power derating when temperature is high.
PV short circuit and PV reverse polarity protection.
PV reverse current protection.
Internal temperature sensor
Compensates absorption and float charge voltage for temperature.
Real-time data display options
- Color Control GX or other GX devices:
see the Venus documents on our website.
- A smartphone or other Bluetooth-enabled device:
VE.Direct Bluetooth Smart dongle needed.

MPPT MPPT MPPT MPPT MPPT


BlueSolar Charge Controller
150/45 150/60 150/70 150/85 150/100
Battery voltage 12 / 24 / 48V Auto Select (software tool needed to select 36V)
Rated charge current 45A 60A 70A 85A 100A
Nominal PV power, 12V 1a,b) 650W 860W 1000W 1200W 1450W
Nominal PV power, 24V 1a,b) 1300W 1720W 2000W 2400W 2900W
Solar Charge Controller
Nominal PV power, 48V 1a,b) 2600W 3440W 4000W 4900W 5800W
MPPT 150/100-MC4
Max. PV short circuit current 2) 50A 50A 50A 70A 70A
150V absolute maximum coldest conditions
Maximum PV open circuit voltage
145V start-up and operating maximum
Maximum efficiency 98%
Self-consumption 10 mA
Charge voltage 'absorption' Default setting: 14,4 / 28,8 / 43,2 / 57,6V (adjustable)
Charge voltage 'float' Default setting: 13,8 / 27,6 / 41,4 / 55,2V (adjustable)
Charge algorithm multi-stage adaptive
Temperature compensation -16 mV / -32 mV / -64 mV / °C
Battery reverse polarity (fuse, not user accessible)
Protection
PV reverse polarity / Output short circuit / Over temperature
Operating temperature -30 to +60°C (full rated output up to 40°C)
Humidity 95%, non-condensing
Data communication port and
VE.Direct (see the data communication whitepaper on our website)
remote on-off
Parallel operation Yes (not synchronized)
ENCLOSURE
Colour Blue (RAL 5012)
35 mm² / AWG2 (Tr models)
Maximum Power Point Tracking
PV terminals 3) Two sets of MC4 connectors (MC4 models up to 150/70)
Three sets of MC4 connectors (MC4 models 150/85 and 150/100)
Upper curve: Battery terminals 35 mm² / AWG2
Output current (I) of a solar panel as function of Protection category IP43 (electronic components), IP22 (connection area)
output voltage (V).
Weight 3kg 4,5kg
The Maximum Power Point (MPP) is the point
Pmax along the curve where the product I x V Tr models: 185 x 250 x 95 Tr models: 216 x 295 x 103
Dimensions (h x w x d) in mm
reaches its peak. MC4 models: 215 x 250 x 95 MC4 models: 246 x 295 x 103
STANDARDS
Lower curve: Safety EN/IEC 62109-1, UL 1741, CSA C22.2
Output power P = I x V as function of output 1a) If more PV power is connected, the controller will limit input power.
voltage. 1b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V.
When using a PWM (not MPPT) controller the
2) A PV array with a higher short circuit current may damage the controller.
output voltage of the solar panel will be nearly 3) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels.
equal to the voltage of the battery, and will be Maximum current per MC4 connector: 30A (the MC4 connectors are parallel connected to one MPPT tracker)
lower than Vmp.

Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands


General phone: +31 (0)36 535 97 00 | E-mail: [email protected]
www.victronenergy.com

You might also like