Operation Manual: Supermagnum 220 Elc
Operation Manual: Supermagnum 220 Elc
Operation Manual: Supermagnum 220 Elc
11/04
von Oertzen GmbH • Ferdinand-Harten-Str. 10 • 22949 Ammersbek • Tel. +49 40 604110 • Fax +49 40 6041149
www.oertzen-gmbh.de • [email protected]
1. Introduction Page 3
4. Start-up/Shut-down Page 8 - 12
Important Notes
We point out that we cannot be held responsible for any damages and/or
malfunctions which may be caused by disregarding this instruction
manual.
According to the rules and regulations for liquid blasters, item 6, as well as
VBG 87 (working with liquid blasters) the machine to be inspected yearly by
qualified personnel, in order to guarantee safe operation.
All rights reserved. Any use in other than legally authorised cases requires the
prior written approval of ARNDT H. von OERTZEN (GmbH&Co).
This machine must only be operated by qualified personnel who are fully
familiar with the operation and possible dangers. The operating instructions
laid down in the “Regulations for liquid blasters (ZH 1/406)” as well as
“Working with liquid blasters” (BGV D 15) strictly to be followed.
The water stream emerging from the spray pistol at high speed has a rather
dangerous cutting effect. So, never direct the water stream onto persons or
animals, nor direct it onto electric units. When starting the machine, be aware
of torque and recoil. Take care of stable foothold.
The max. pressure stated on the nameplate must not be exceeded. The safety
valve opens as soon as the max. operating pressure is exceeded by 10 %.
The safety/control valve is workshop adjusted and sealed. The adjustment
must not be changed.
Unsuitable or defective high pressure hoses very often cause accidents during
operation of high pressure cleaners. Therefore, check the hoses for damages
before any start-up. Defective hoses immediately to be replaced by original
OERTZEN equipment. Using other materials than original OERTZEN equip-
ment (union respectively hose marked with “OERTZEN”) or using materials
which have not expressively been approved by OERTZEN in writing voids all
warranties and product liability.
Worn out and/or defective high pressure hoses must never be repaired and
reused, but replaced immediately.
Spray pistols with delayed closing mechanism must not be used, due to risk of
injuries.
Lever in open position must not be blocked or fixed in any other way.
When using spray lance of less than 750 mm length particular dangers to be
considered.
Machine not to be started in case power cable, plugs, switches, etc. are
defective.
Make sure that the unit cannot move. In case the unit is equipped with a brake;
it should be activated during working in steep areas.
Repair work within the high pressure section of the machine (pump, hoses,
piping) only to be carried out by qualified engineers.
The hot water high pressure cleaner comprises an inline plunger high pressure
pump with safety shut-down system a high capacity oil heating system with
stainless steel heat exchanger.
The high pressure pump is directly flanged to the electric motor. It sucks the
feed water from a level controlled water tank and directs it via the safety/
control unit into a heating coil where it is heated up to operating temperature.
Between high pressure pump and heating coil a safety/control valve is installed
which opens as soon as max. operating temperature is exceeded by more
than 10 % and returns the water which is not taken by the nozzle into the
suction line of the pump.
By activating the heating system, the fuel pump sucks fuel from the storage
tank via a filter system and injected into the burner chamber. The required
oxygen is pressed into the burner chamber by a blower system. The mixture is
atomized and ignited by the ignition electrodes which are continuously
powered by the high voltage transformer. The heating flame totally burns
without touching the heat exchanger shells. During this procedure infra-red
rays are generated which, in common with hot exhaust fumes, economically
heat up the water to the working temperature which is adjusted at the
thermostat.
The working pressure can continuously be adjusted by means of the adjusting
handle at the double lance.
If required, suitable detergent can be injected into the water stream from the
storage tank, via filter and non-return valve and applied onto the cleaning
object.
The machine is equipped with a safety shut-down system. When closing the
spray pistol the machine keeps on running for approx. 15 seconds in
circulation mode and afterwards switches into stand-by mode. In prallel, a
safety-/control unit interrupts the fuel supply so that the burner is deactivated.
When releasing the spray pistol again, the machine is restarted, pressure
generated and burner activated, so that the cleaning task can be continued
without delay.
Before Start-up
Connections
Water Connection
Water inlet (6) of the unit to be connected to the water distribution network by
means of an internally clean, min. ” water hose (diameter: see table below).
For connections to the potable water distribution network DIN 1988 to be
considered (for short-time connection a back-flow preventer with non-return
protection and ventilation to be used).
Unlock and release spray pistol, bleed the unit until blister-free water emerges.
Pressure Adjustment
The working pressure can be continuously be adjusted by opening/closing the
handle at the double lance.
Counter-clockwise: pressure decrease
Clockwise: pressure increase
When moving the machine, be aware of hot exhaust fumes at the boiler
outlet wile burner is in operation.
10
Turn adjusting knob at the detergent dosing valve (16) to required concen-
tration and apply it onto the surface of the cleaning object from the bottom to
the top. Detergent to work in, but must not dry. Turn detergent dosing valve
(16) into position 0. Wash detergent from the cleaning object from the bottom
to the top. Keep a spray distance of approx. 10 – 20 cm. Detergent residues to
be flushed from the cleaning object completely.
After use of detergents, operate the machine with clean water for a
couple of minutes, in order to completely flush the detergent out of
the system.
11
Reel off high pressure hose and thoroughly clean it. In case of damage
replace it for safety reasons.
Using other materials than original OERTZEN equipment (hand nut respec-
tively hose marked with “OERTZEN”) or using materials which have not
expressively been approved by OERTZEN in writing ceases warranty and
product liability.
Particularly Note
In case of malfunctions switch off machine immediately, eliminate cause
according to chapter "Trouble Shooting", call qualified service.
12
It is most important that the operator carries out the following maintenance
work in shorter time periods than the normal maintenance intervals:
Strainer
A strainer (6 a) is installed at the water inlet which has to be checked prior to
start-up and cleaned/replaced whenever necessary.
Fuel Filter
Between fuel pump and fuel tank there are two filters installed which have to
be replaced regularly.
Fuel Tank
Immediately remove deposits in the fuel tank (19), if any.
13
The boiler cleaning and the adjustment of the burner unit afterwards to be
carried out by qualified service.
In areas with excessive water hardness, at least every 200 operating hours the
system should be flushed with anti-scalant liquid during regular maintenance.
14
All maintenance intervals stated apply under the provision that the
machine will be operated according to design limits and that the machine
will be fed with clean water/consumables. Otherwise maintenance
intervals to be shortened.
All maintenance instructions laid down in this manual are part of our
warranty terms. Disregarding maintenance instructions ceases warranty.
15
• Start machine, open spray pistol, stop water supply. Wait until pressure
drops, stop machine.
• Fill approx. 3 l of a commercial anti-freeze (Glysantin) into the water tank.
Start machine
• Spray pistol/stop valve to be opened and closed several times until anti-
freeze can be detected in the water stream.
• Stop machine.
• Machine is now protected against temperatures of –25 °C.
16
7. Technical Data
17
18