USER MANUAL
HMSI-27-262 4.0 en-US ENGLISH
Important User Information
Disclaimer
The information in this document is for informational purposes only. Please inform HMS Industrial Networks of any
inaccuracies or omissions found in this document. HMS Industrial Networks disclaims any responsibility or liability
for any errors that may appear in this document.
HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous product
development. The information in this document shall therefore not be construed as a commitment on the part of
HMS Industrial Networks and is subject to change without notice. HMS Industrial Networks makes no commitment
to update or keep current the information in this document.
The data, examples and illustrations found in this document are included for illustrative purposes and are only
intended to help improve understanding of the functionality and handling of the product. In view of the wide range
of possible applications of the product, and because of the many variables and requirements associated with any
particular implementation, HMS Industrial Networks cannot assume responsibility or liability for actual use based on
the data, examples or illustrations included in this document nor for any damages incurred during installation of the
product. Those responsible for the use of the product must acquire sufficient knowledge in order to ensure that the
product is used correctly in their specific application and that the application meets all performance and safety
requirements including any applicable laws, regulations, codes and standards. Further, HMS Industrial Networks will
under no circumstances assume liability or responsibility for any problems that may arise as a result from the use of
undocumented features or functional side effects found outside the documented scope of the product. The effects
caused by any direct or indirect use of such aspects of the product are undefined and may include e.g. compatibility
issues and stability issues.
1 Preface ................................................................................................................................. 3
1.1 About This Document .......................................................................................................3
1.2 Document history ............................................................................................................3
1.3 Document Conventions .....................................................................................................4
1.4 Document-specific Conventions..........................................................................................4
2 Description .......................................................................................................................... 5
2.1 Introduction ....................................................................................................................5
2.2 Data Exchange.................................................................................................................6
2.3 Status and Diagnostics ......................................................................................................7
2.4 Controlling the X-gateway from the Network ........................................................................9
2.5 Error Handling .................................................................................................................9
2.6 Data Mapping Examples .................................................................................................. 10
3 Installation......................................................................................................................... 11
3.1 DIN Rail Mount .............................................................................................................. 11
3.2 Connectors and Indicators ............................................................................................... 12
1 Preface
1.1 About This Document
This document describes the functions and general configuration of the Anybus X-gateway.
Documentation and software for the specific fieldbus and Ethernet network interfaces can be
downloaded from www.anybus.com/support.
This instruction must be followed to avoid a risk of reduced functionality and/or damage
to the equipment, or to avoid a network security risk.
Caution
This instruction must be followed to avoid a risk of personal injury.
WARNING
This instruction must be followed to avoid a risk of death or serious injury.
2 Description
2.1 Introduction
The Anybus X-gateway consists of two Anybus fieldbus or Ethernet network interface modules
and an intelligent gateway platform which transfers data between the two networks.
The X-gateway can be configured via a USB port using a Windows-based application, Anybus
Configuration Manager. The on-board network interfaces are normally configured from the
respective networks, using third-party configuration tools.
This document describes only the gateway platform. The network interfaces are described in
their own documentation.
The terminology and definitions used for different types of data vary between different network
types. Most networks distinguish between fast, cyclical I/O data, and less time-critical acyclic
data. In the Anybus X-gateway these types of data are generally referred to respectively as I/O
Data and Parameter Data.
Each of the two network interfaces exchanges data on its network through its own buffer, which
can hold up to 512 bytes of data. The actual amount of data that can be exchanged depends on
the settings in the network interface and may therefore be significantly less than 512 bytes,
which is only the maximum size of the buffer. The default setting is 20 bytes in each direction.
See the documentation for the respective network interface for more information.
In addition to the I/O data the buffers may contain network status information and instructions
for controlling the network interface. Depending on the type of network interface this may be
general diagnostic information (Status Word), a list of the active slaves (Live List), or other
network-specific information. In a network master, part of the buffer may be used to start/stop
data exchange and to reset the gateway (Control Word).
The exchange of data between the buffers is separate from the network data exchange. While
the X-gateway ensures data consistency (where applicable), it does not feature any mechanisms
for synchronisation between the two networks.
The Status Word is disabled by default and must be enabled for each network separately through
Anybus Configuration Manager.
(MSB) (LSB)
bit 15 bit 14 bit 13 bit 12 bit 11 bit 10 bit 9 bit 8 bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
Gateway Cycle Counter General Error Counter (reserved) Master Mode Init Run
Init
Indicates if the other network interface has been initialized.
Bit set (1) = Other network interface successfully initialized
Bit cleared (0) = Could not initialize other network interface
Run
Indicates the status of the data exchange on the other network.
(MSB) (LSB)
bit 15 bit 14 bit 13 bit 12 bit 11 bit 10 bit 9 bit 8 bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
Reset Master Mode
The exact definition depends on the network interface type. See the documentation for the
respective interface for more information.
Reset
Can be used to reset the Anybus X-gateway.
Bit set (1) = Restart the gateway and re-initialize both network interfaces
Bit cleared (0) = No action
This example illustrates how data is mapped in a typical slave-to-slave gateway configuration.
The Control Word and Status Word is here enabled for both networks.
This example illustrates how data is mapped in a typical master-to-slave gateway configuration.
The mapping is similar to the slave-to-slave configuration but also features the Live List, which
indicates the active status of the slaves that are attached to the master interface.
3 Installation
3.1 DIN Rail Mount
The unit is designed to be mounted on a standard DIN rail. No tools are needed.
The unit must be electrically grounded through the DIN rail for EMC compliance. Make
sure that the unit is correctly mounted on the rail and that the rail is properly grounded.
Sideways mounting
The unit can alternatively by mounted sideways on the DIN rail. A T10 Torx screwdriver is needed
to reposition the DIN clip.
1. Remove the sticker covering the screw holes on the right side panel.
2. Unscrew the DIN clip from the back of the unit. Use a T10 Torx screw driver.
3. Refit the DIN clip to the side panel.
Fig. 7 Connectors
Connecting power with reverse polarity or using the wrong type of power supply may
damage the equipment. Make sure that the power supply is connected correctly and of
the recommended type.
Pin Signal
1 +24 VDC
2 Power Ground
Other LED indicators, connectors and configuration switches are described in the documentation
for each respective network interface.
The gateway settings are accessed via the USB port of the X-gateway using the Windows-based
application Anybus Configuration Manager.
This section describes only the general features and how to install Anybus Configuration Manager.
The network-specific settings are described in detail in the built-in help system and in the
documentation for each respective interface.
4.2 Setup
1. Download Anybus Configuration Manager and Anybus Transport Provider from
www.anybus.com/support.
2. Unzip the contents of each archive in a folder on your computer and double-click on the
setup executable, then follow the instructions in the installation wizard.
3. Connect a USB cable between the computer and the USB port on the X-gateway.
4. Start Anybus Configuration Manager and select Online > Select Connection.
5. Select the connection to use for the X-gateway and click on OK. The USB connection will be
named Anybus Serial Connection.
There is normally no need to configure the connection unless you are connected to more
than one X-gateway. See the built-in help for more information.
6. Select Online > Connect to open the connection to the X-gateway.
4.3 Configuration
Once Anybus Configuration Manager has established a connection to the X-gateway,
configurations from the unit can be retrieved, viewed and modified.
1. Select Online > Upload Configuration to retrieve the configuration from the X-gateway.
2. The configuration can now be viewed and modified as required.
3. After making changes, select Online > Download Configuration to apply the modified
configuration to the X-gateway.
For more information about the various functions and settings, see the built-in help in Anybus
Configuration Manager and the documentation for each network interface.
A Technical Data
Technical Specifications
Model name Anybus X-gateway
Dimensions (L x W x H) 114 x 44 x 127 mm
Weight 400 g
Operating temperature -25 to +65 °C (IEC 60068-2-1 and IEC 60068-2-2)
(max. +50 °C for fibre optic interfaces)
Storage temperature -40 to +85 °C (IEC 60068-2-1 and IEC 60068-2-2)
Humidity range 5–95 % RH, non-condensing (IEC 60068-2-30)
Pressure range 85–105 kPa
Power supply 24 V ±20 % DC regulated power source
Current consumption Typical: 200 mA @ 24 VDC
Maximum: 400 mA @ 24 VDC
Configuration port USB (USB to CAN cable not included)
Galvanic isolation Yes, on both network sides
Mechanical rating IP20, NEMA rating 1
Mounting DIN rail (EN 50022)
Network shield conductance via DIN rail
Certifications See www.anybus.com/support