Example Phase
Example Phase
Design the three phase for intersection shown below with a (6 sec)
intergreen period on first phase and (5 sec) intergreen for other phases and
5 percentage trucks for all approaches .
4.5 m
20 veh/hr
30 veh/hr
510 veh/hr
3.05
m
65 veh/hr
Phase 3
Phase 1 Phase 2
Sol.
Phase 1:
q= RT+TH+(1.75LT)
= [20+700+(1.75x30)]x[(0.95x1)+(0.05x2)] ≈812 PCU/hr.
S = SoFwFH.VFgFpedFLF
𝑤−3.6 3.05−3.6
𝐹𝑤 = 1 + =1+ = 0.939
9 9
100 100
𝐹𝐻.𝑉 = = = 0.952
100+𝐻.𝑉%(𝐸𝑝 −1) 100+5
1 1
𝐹𝐿𝐹 = = = 0.998
1 + 0.05𝑃𝐿𝑇 30
1 + 0.05 ( )
20 + 700 + 30
S = 1900x2x0.939x0.952x0.998x1x1≈ 3391 PCU/hr.
Phase 1:
q= RT+TH+(1.75LT)
= [35+620+(1.75x65)]x[(0.95x1)+(0.05x2)] ≈808 PCU/hr.
S = SoFwFH.VFgFpedFLF
𝑤−3.6 3.05−3.6
𝐹𝑤 = 1 + =1+ = 0.939
9 9
100 100
𝐹𝐻.𝑉 = = = 0.952
100+𝐻.𝑉%(𝐸𝑝 −1) 100+5
1 1
𝐹𝐿𝐹 = = = 0.996
1 + 0.05𝑃𝐿𝑇 65
1 + 0.05 ( )
35 + 620 + 65
S = 1900x2x0.939x0.952x0.996x1x1≈ 3384 PCU/hr.
Phase 2:
q= RT+TH+(1.75LT)
= [20+370+(1.75x30)]x[(0.95x1)+(0.05x2)] ≈465 PCU/hr.
S = SoFwFH.VFgFpedFLF
𝑤−3.6 4.5−3.6
𝐹𝑤 = 1 + =1+ = 1.1
9 9
100 100
𝐹𝐻.𝑉 = = = 0.952
100+𝐻.𝑉%(𝐸𝑝 −1) 100+5
1 1
𝐹𝐿𝐹 = = = 0.996
1 + 0.05𝑃𝐿𝑇 30
1 + 0.05 ( )
20 + 370 + 30
S = 1900x1x1.1x0.952x0.996x1x1≈ 1982 PCU/hr.
Phase 3:
q= RT+TH+(1.75LT)
= [50+510+(1.75x40)]x[(0.95x1)+(0.05x2)] ≈812 PCU/hr.
S = SoFwFH.VFgFpedFLF
𝑤−3.6 4.5−3.6
𝐹𝑤 = 1 + =1+ = 1.1
9 9
100 100
𝐹𝐻.𝑉 = = = 0.952
100+𝐻.𝑉%(𝐸𝑝 −1) 100+5
1 1
𝐹𝐿𝐹 = = = 0.997
1 + 0.05𝑃𝐿𝑇 0
1 + 0.05 ( )
50 + 510 + 40
S = 1900x1x0.939x0.952x0.997x1x1≈ 1984 PCU/hr.
𝐿 = ∑(𝐼𝐺 − 1) = (6 − 1) + (5 − 1) + (5 − 1) = 13 𝑠𝑒𝑐.
1.5𝐿+5 1.5𝑥13+5
𝐶𝑜 = = = 128 𝑠𝑒𝑐.
1−∑ 𝑌𝑚𝑎𝑥. 1−0.809
𝐶𝑜 = 120 𝑠𝑒𝑐. 60 𝑠𝑒𝑐. ≤ 𝐶0 ≥ 120 𝑠𝑒𝑐.
𝐺𝑇 = 𝐶𝑜 − 𝐿 = 120 − 13 = 107 𝑠𝑒𝑐.
𝑌𝑚𝑎𝑥. 0.240
𝑔𝑝ℎ.1 = ∑ 𝑌𝑚𝑎𝑥.
𝑥𝐺𝑇 = 𝑥107 = 32 𝑠𝑒𝑐.
0.809
Phase2
R= 81 sec. IG = 5 sec. G=31sec. A=3sec.
Phase3
R= 68 sec. IG = 5 sec. G= 44sec. A=3sec.