The document describes a three phase intersection with given traffic volumes and asks to design the signal timing. The summary is: 1) Traffic volumes and saturation flows were calculated for each phase. 2) The critical cycle length was determined to be 120 seconds. 3) The green times were allocated to each phase proportionally based on the saturation flow ratios to maximize the intersection capacity. 4) The results were a 31 second green, 3 second amber, and 86 second red for phase 1. Phase 2 was 31 green, 5 intergreen, and 81 red. Phase 3 was 44 green, 5 intergreen, and 68 red.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views

Example Phase

The document describes a three phase intersection with given traffic volumes and asks to design the signal timing. The summary is: 1) Traffic volumes and saturation flows were calculated for each phase. 2) The critical cycle length was determined to be 120 seconds. 3) The green times were allocated to each phase proportionally based on the saturation flow ratios to maximize the intersection capacity. 4) The results were a 31 second green, 3 second amber, and 86 second red for phase 1. Phase 2 was 31 green, 5 intergreen, and 81 red. Phase 3 was 44 green, 5 intergreen, and 68 red.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Example:

Design the three phase for intersection shown below with a (6 sec)
intergreen period on first phase and (5 sec) intergreen for other phases and
5 percentage trucks for all approaches .

4.5 m

20 veh/hr

50 veh/hr 40 veh/hr 700 veh/hr

30 veh/hr
510 veh/hr

3.05
m

65 veh/hr

30 veh/hr 370 veh/hr


620 veh/hr
20 veh/hr
35 veh/hr

Phase 3
Phase 1 Phase 2
Sol.
Phase 1:
q= RT+TH+(1.75LT)
= [20+700+(1.75x30)]x[(0.95x1)+(0.05x2)] ≈812 PCU/hr.
S = SoFwFH.VFgFpedFLF
𝑤−3.6 3.05−3.6
𝐹𝑤 = 1 + =1+ = 0.939
9 9
100 100
𝐹𝐻.𝑉 = = = 0.952
100+𝐻.𝑉%(𝐸𝑝 −1) 100+5

1 1
𝐹𝐿𝐹 = = = 0.998
1 + 0.05𝑃𝐿𝑇 30
1 + 0.05 ( )
20 + 700 + 30
S = 1900x2x0.939x0.952x0.998x1x1≈ 3391 PCU/hr.
Phase 1:
q= RT+TH+(1.75LT)
= [35+620+(1.75x65)]x[(0.95x1)+(0.05x2)] ≈808 PCU/hr.
S = SoFwFH.VFgFpedFLF
𝑤−3.6 3.05−3.6
𝐹𝑤 = 1 + =1+ = 0.939
9 9
100 100
𝐹𝐻.𝑉 = = = 0.952
100+𝐻.𝑉%(𝐸𝑝 −1) 100+5

1 1
𝐹𝐿𝐹 = = = 0.996
1 + 0.05𝑃𝐿𝑇 65
1 + 0.05 ( )
35 + 620 + 65
S = 1900x2x0.939x0.952x0.996x1x1≈ 3384 PCU/hr.
Phase 2:
q= RT+TH+(1.75LT)
= [20+370+(1.75x30)]x[(0.95x1)+(0.05x2)] ≈465 PCU/hr.
S = SoFwFH.VFgFpedFLF
𝑤−3.6 4.5−3.6
𝐹𝑤 = 1 + =1+ = 1.1
9 9
100 100
𝐹𝐻.𝑉 = = = 0.952
100+𝐻.𝑉%(𝐸𝑝 −1) 100+5

1 1
𝐹𝐿𝐹 = = = 0.996
1 + 0.05𝑃𝐿𝑇 30
1 + 0.05 ( )
20 + 370 + 30
S = 1900x1x1.1x0.952x0.996x1x1≈ 1982 PCU/hr.
Phase 3:
q= RT+TH+(1.75LT)
= [50+510+(1.75x40)]x[(0.95x1)+(0.05x2)] ≈812 PCU/hr.
S = SoFwFH.VFgFpedFLF
𝑤−3.6 4.5−3.6
𝐹𝑤 = 1 + =1+ = 1.1
9 9
100 100
𝐹𝐻.𝑉 = = = 0.952
100+𝐻.𝑉%(𝐸𝑝 −1) 100+5

1 1
𝐹𝐿𝐹 = = = 0.997
1 + 0.05𝑃𝐿𝑇 0
1 + 0.05 ( )
50 + 510 + 40
S = 1900x1x0.939x0.952x0.997x1x1≈ 1984 PCU/hr.

Variable Phase 1 Phase 2 Phase 3


q(PCU/hr) 812 808 465 662
S(PCU/hr) 3391 3384 1982 1984
Y = q/s 0.240 0.239 0.235 0.334
Ymax. 0.240 0.235 0.334
∑ 𝑌𝑚𝑎𝑥. 0.809

𝐿 = ∑(𝐼𝐺 − 1) = (6 − 1) + (5 − 1) + (5 − 1) = 13 𝑠𝑒𝑐.
1.5𝐿+5 1.5𝑥13+5
𝐶𝑜 = = = 128 𝑠𝑒𝑐.
1−∑ 𝑌𝑚𝑎𝑥. 1−0.809
𝐶𝑜 = 120 𝑠𝑒𝑐. 60 𝑠𝑒𝑐. ≤ 𝐶0 ≥ 120 𝑠𝑒𝑐.
𝐺𝑇 = 𝐶𝑜 − 𝐿 = 120 − 13 = 107 𝑠𝑒𝑐.
𝑌𝑚𝑎𝑥. 0.240
𝑔𝑝ℎ.1 = ∑ 𝑌𝑚𝑎𝑥.
𝑥𝐺𝑇 = 𝑥107 = 32 𝑠𝑒𝑐.
0.809

𝐺𝑝ℎ.1 = 𝑔𝑝ℎ.1 − 1 = 32 − 1 = 31 𝑠𝑒𝑐.


𝑌𝑚𝑎𝑥. 0.235
𝑔𝑝ℎ.2 = ∑ 𝑌𝑚𝑎𝑥.
𝑥𝐺𝑇 = 𝑥107 = 32 𝑠𝑒𝑐.
0.809

𝐺𝑝ℎ.2 = 𝑔𝑝ℎ.2 − 1 = 32 − 1 = 31 𝑠𝑒𝑐.


𝑌𝑚𝑎𝑥. 0.334
𝑔𝑝ℎ.3 = ∑ 𝑌𝑚𝑎𝑥.
𝑥𝐺𝑇 = 𝑥107 = 45 𝑠𝑒𝑐.
0.809

𝐺𝑝ℎ.3 = 𝑔𝑝ℎ.3 − 1 = 45 − 1 = 44 𝑠𝑒𝑐.


Phase 1
G = 31 sec. A = 3 sec. R = 86 sec.

Phase2
R= 81 sec. IG = 5 sec. G=31sec. A=3sec.

Phase3
R= 68 sec. IG = 5 sec. G= 44sec. A=3sec.