FreshWater Generator On Ships
FreshWater Generator On Ships
FreshWater Generator On Ships
Operation
Extreme care must be taken during the operation of
fresh water generator onboard ships. Operate all the
valves gradually. Sudden opening and closing of valves
may result in thermal shock to the main engine. Also
make sure that distillate pump never runs dry.
Fresh water Generator Starting Procedure
Make sure seawater ejector pump suction, discharge and
overboard valves are open. Start the ejector pump.
Seawater pressure at the air ejector must be 3 bar or
more.
Wait for vacuum to build up inside fresh water generator
shell. (About 92 % vacuum).
Open the feed water valve to feed seawater to the
evaporator. Adjust the feed water pressure. Normally
marking is provided on the pressure gauge for desired
feed water pressure.
Open main engine jacket cooling water inlet and outlet
to the evaporator gradually.
Open the air vent clock at the top of the evaporator to
make sure the evaporator is filled with jacket cooling
water. Air must be purged out if any.
Switch on the salinity alarm panel for measuring purity of
the freshwater produced.
There will be a sight glass provided at the suction line for
the distillate pump. Make sure condensed water is
coming to the suction line. Now start the distillate pump
and open discharge valve to lead generated water to
specified storage tanks.
Do checks While Running Fresh water Generator
Through the sight glass provided in the evaporator shell,
observe flashing of water.
Also check for the brine level inside. It should not be too
high or too low.
Shell temperature must be around 50 deg cel.
Make sure shell vacuum is more than 90% from the
vacuum gauge.
Check seawater inlet and outlet temperature to the
condenser.
Ensure seawater pressure at air ejector inlet more than 3
bars.
Check for distillate pump pressure and water flow meter.
Check salinity of fresh water produced.
Check level and flow of dosing chemical.
Check ampere of ejector pump and distillate pump
motor.
Regulating the Capacity of Fresh water Generator
Capacity of a fresh water generator means the quantity
of fresh water produced by it per day. The capacity of
fresh water generator can be varied by reducing or
increasing the amount of jacket cooling water to the
evaporator. The quantity of jacket cooling water to the
evaporator can be adjusted by adjusting the bypass valve
provided. When the temperature of jacket cooling water
is comparatively low, the quantity to the evaporator to
be increased a bit. At the same time cooling seawater
pressure to the condenser also to be regulated
accordingly.