ASCO Series 551 Spool Valves
ASCO Series 551 Spool Valves
ASCO Series 551 Spool Valves
551 series
threaded G 1/4
integral pilots
Fluids air or inert gas, filtered, lubricated or not • Non breathing design, protecting the actuator
Operating pressure 2 to 10 bar or 2 to 8 bar (CNOMO pilot versions) from ingress of the atmosphere
Pilot pressure internal piloting or 2 to 10 bar (external piloting) • Wide temperature range for harsh environments
Ambient temperature -25°C to +60°C (-25°C to +60°C)
Flow (Qv at 6 bar) (ANR) 860 l/min (700 l /min for Namur versions) • Reliability: long service life, 30 million cycles
Body black anodised aluminium
• Can be attached to supply rail for fast
Internal parts zamak, stainless steel, POM (polyacetal), aluminium pneumatic installation
End plates PA (polyamide), glass-fibre reinforced
• Compact dimensions for optimum integration
Sealings NBR (nitrile) + PUR (polyurethane)
with the actuators
Standard voltages DC (=) 24V-48V
AC (~) 24V-48V-115V-230V/50Hz
YOUR SELECTION
power code standard voltages (V)
integral pilot versions for valve piloting ~ = AC (~) / 50Hz DC (=)
(1)
VA W (M) connector 24 48 115 230 24 48
3/2 NC - solenoid air operated - spring return (monostable function)
2 4
2 4
12
SCG551A017MS 3,5 3 ● size 22 (2) 3 3 3 3 3
3 5
1
1 1 SCG551A001 ✕ 3
1 1
Ports
1 : Pressure 5 4 1 2 3
C
3 2 1
2-4 : Outlet
3-5 : Exhaust
F E F E
2
: manual operator
2 4 2
2
B
B
G
G
D
D
M5 M5
3 1 5 1 3
1 1
A1 A1
A2 A2
2 mounting holes:
1 5,3 mm dia. (Spotfacing: 9 mm dia., depth 5 mm) (series 551)
2 6,5 mm dia. (Spotfacing: 11 mm dia., depth 6 mm) (series 552-553)
83 24 2
3 3/2 NC
Ports adapt the plate 3/2 under
72
3/2
1 : Pressure the spool valve
32
45
2 4
2-4 : Outlet M5
3-5 : Exhaust
1 5
5/2
the spool valve