Industrial Spark-Ignited Generator Set: Demand Response Ready Standby Power Rating
Industrial Spark-Ignited Generator Set: Demand Response Ready Standby Power Rating
Industrial Spark-Ignited Generator Set: Demand Response Ready Standby Power Rating
9L | 750 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
ANSI C62.41
owner experience and higher confidence level. Generac
spark-ignited engines give you more options in com-
mercial and industrial generator applications as well as
extended run time from utility-supplied natural gas.
1 of 6
SG750 | 33.9L | 750 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
CONTROL SYSTEM • Wi-Fi®, Bluetooth®, BMS and Remote Telemetry 7 Inch Color Touch Screen Display
• •
Built-In Programmable Logic Eliminates the Need for
External Controllers Under Most Conditions Resistive Color Touch Screen
• Ethernet Based Communications • Sunlight Readable (1400 NITS)
Between Generators • Easily Identifiable Icons
• Programmable I/O Channel Properties • Multi-Lingual
• Built-In Diagnostics • On Screen Editable Parameters
• Key Function Monitoring
Protections • Three Phase Voltage, Amperage, kW, kVA, and kVAr
• Low Oil Pressure • Selectable Line to Line or Line to
• Low Coolant Level Neutral Measurements
• High/Low Coolant Temperature • Frequency
• Sensor Failure • Engine Speed
• Oil Temperature • Engine Coolant Temperature
Power Zone® Pro Sync Controller • Over/Under Speed • Engine Oil Pressure
• Over/Under Voltage • Engine Oil Temperature
Program Functions • Over/Under Frequency • Battery Voltage
• NFPA 110 Level 1 Compliant • Over/Under Current • Hourmeter
• Engine Protective Functions • Over Load • Warning and Alarm Indication
• Alternator Protective Functions • High/Low Battery Voltage • Diagnostics
• Digital Engine Governor Control • Battery Charger Current • Maintenance Events/Information
SPEC SHEET
• Digital Voltage Regulator • Phase to Phase and Phase to Neutral Short Circuits
• Multiple Programmable Inputs and Outputs (I2T Algorithm)
• Remote Display Capability
• Remote Communication via Modbus® RTU, Mod-
bus TCP/IP, and Ethernet 10/100
• Alarm and Event Logging with Real Time Stamping
• Expandable Analog and Digital Inputs and Outputs 2 of 6
• Remote Wireless Software Update Capable
SG750 | 33.9L | 750 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
GENERATOR SET
○ Spring Vibration Isolator
○ Extended Factory Testing (3-Phase Only)
○ 24 Position Load Center
ENGINEERED OPTIONS
3 of 6
SG750 | 33.9L | 750 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
ENGINE SPECIFICATIONS
Lubrication System
Oil Pump Type Gear Driving
Oil Filter Type Full Flow Spin-on Cartridge
Crankcase Capacity - qt (L) 126.8 (120)
ALTERNATOR SPECIFICATIONS
4 of 6
SG750 | 33.9L | 750 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
COOLING
Standby/Demand Response
Air Flow (Fan Air Flow Across Radiator) - Open Set scfm (m3/min) 34,000 (963)
Coolant Flow gpm (Lpm) 291 (1,101)
Coolant System Capacity gal (L) 55 (208)
Maximum Operating Ambient Temperature °F (°C) 122 (50)
Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD
Maximum Additional Radiator Backpressure in H2O (kPa) 0.5 (0.12)
ENGINE EXHAUST
Standby/Demand Response Standby/Demand Response
Rated Engine Speed RPM 1,800 Exhaust Flow (Rated Output) scfm (m3/min) 5,449 (154.3)
Maximum Allowable Backpressure
Horsepower at Rated kW** hp 1,118 inHg (kPa) 1.97 (6.67)
(Post Silencer)
SPEC SHEET
** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, and DIN6271 standards. 5 of 6
Standby – See Bulletin 10000018933
Prime – See Bulletin 10000018926
Demand Response – See Bulletin 10000018250
SG750 | 33.9L | 750 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
OPEN SET
L x W x H - in (mm) 178.3 (4,528) x 82.6 (2,098) x 110.3 (2,801)
H Weight - lbs (kg) 14,352 - 14,932 (6,510 - 6,773)
L W
L W
L W
L W
Specification characteristics may change without notice. Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings.
6 of 6
Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53189 Part No. 10000024335
P: (262) 544-4811 ©2020 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Rev. D 05/13/2020