C66 D5L - Data Sheet PDF
C66 D5L - Data Sheet PDF
C66 D5L - Data Sheet PDF
Standby Prime
Fuel consumption kVA (kW) kVA (kW)
Ratings 66 (53) 60 (48)
Load ¼ 1/2 3/4 Full 1/4 1/2 3/4 Full
US gph 1.2 2.0 3.0 4.1 1.2 1.8 2.7 4.1
L/hr 4.7 7.4 11.4 15.4 4.4 6.9 10.1 13.3
Standby Prime
Engine rating rating
Engine manufacturer Cummins
Engine model 4BTAA3.3-G13
Configuration Inline, 4-Cylinder Diesel
Aspiration Turbocharged and after-cooled
Gross engine power output, kWm 62.6 58
BMEP at set rated load, kPa 1538 1428
Bore, mm 95
Stroke, mm 115
Rated speed, rpm 1500
Piston speed, m/s 5.75
Compression ratio 19:1
Lube oil capacity, L 8
Overspeed limit, rpm 1650
Regenerative power, kW N.A.
Governor type Mechanical as standard
Starting voltage 12V DC
Fuel flow
Maximum fuel flow, L/hr 45
Maximum fuel inlet restriction, mm Hg (clean filter) 101.6
Maximum fuel inlet temperature, °C 70
power.cummins.com
©2016 Cummins Power Generation Inc. | D-6278-EN
Air Standby Rating Prim e Rating
Exhaust
Exhaust gas flow at set rated load, m 3/min 10.64 9.76
Enclosed set
Outlines are f or illustrative purposes only. Please refer to the genset outline drawing for an exact representation of this model.
©2012 | Cummins Power Generation Inc. | All rights reserved | Specifications subject to change without notice | Cummins Power Generation and Cummins are registered trademarks of Cummins Inc.
PowerCommand and “Our energy working for you.” are trademarks of Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
Document no. DS374-CPGK-RevA - 24/2/2012
Alternator data
Connection1 Temp rise °C Duty2 VoltageAlternator
0 0 0 0
Applicable f or supplying power to Applicable f or supplying power to a Applicable f or supplying power to Applicable f or supplying power
v ary ing electrical load for the constant electrical load for limited v ary ing electrical load for unlimited continuously to a constant electrical
duration of power interruption of a hours. Limited Time Running Power hours. Prime Power (PRP) is in load f or unlimited hours. Continuous
reliable utility source. Emergency (LTP) is in accordance with ISO accordance with ISO 8528. Ten Power (COP) in accordance with ISO
Standby Power (ESP) is in 8528. percent ov erload capability is 8528, ISO 3046, AS 2789 and DIN
accordance with ISO 8528. Fuel av ailable in accordance with ISO 6271.
Stop power in accordance with ISO 3046, AS 2789 and DIN 6271.
3046, AS 2789 and DIN 6271.
kWxSinglePhaseFactorx1000
Voltage
kWx1000
Voltagex1.73x0.8