Electronic Service Tool 2015A v1.0 Product Status Report

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Electronic Service Tool 2015A v1.

0
Product Status Report

23/07/2020 14:30

Product Status Report


Parameter Value
Engine Serial Number MGBF5027U10881X
Equipment ID VISA SPA
Comments

2506-E15 (MGBF5027U10755X)
Parameter Value
Equipment ID VISA SPA
Engine Serial Number MGBF5027U10881X
ECM Serial Number 28926283JL
Software Group Part Number 3223962-00
Software Group Release Date NOV07
Software Group Description 2506C TAG2 50/60Hz

Critical Events - 2506-E15 (MGBF5027U10755X)


Description Start Time Elapsed Extreme Average
No Critical Events.

Logged Diagnostic Codes [ECM Diagnostic Clock = 2259.7390 hours] - 2506-E15


(MGBF5027U10755X)
Code Description Occ. First Last
No Logged
Diagnostic
Codes

Logged Event Codes [ECM Diagnostic Clock = 2259.7390 hours] - 2506-E15


(MGBF5027U10755X)
Code Description Occ. First Last
No Logged
Events

Active Diagnostic Codes - 2506-E15 (MGBF5027U10755X)


Code Description
No Active
Codes

Active Event Codes - 2506-E15 (MGBF5027U10755X)


Code Description
No Active
Events

Current Totals - 2506-E15 (MGBF5027U10755X)


Description Value Unit
Total Engine Operating Hours 2260 hours

Configuration - 2506-E15 (MGBF5027U10755X)


Description Value Unit
Equipment ID VISA SPA
Engine Serial Number MGBF5027U10881X
ECM Serial Number 28926283JL
Software Group Part Number 3223962-00
Software Group Release Date NOV07
Software Group Description 2506C TAG2 50/60Hz
Rating Number 2
Rated Frequency 50 Hz
Rated Genset Speed 1500 rpm
Rated Real Genset Power Unavailable Parameter
Rated Apparent Genset Power 500 kVA
Engine Rating Application Type Prime
External Speed Selection Switch Installed Enabled
Engine Acceleration Rate 500 rpm/s
Droop/Isochronous Switch Installed Enabled
Droop/Isochronous Selection Isochronous
Engine Speed Droop 4.0 %
Digital Speed Control Installed Installed
Speed Control Minimum Speed 125 rpm
Speed Control Maximum Speed 125 rpm
Digital Speed Control Ramp Rate 10 rpm/s
Crank Terminate RPM 400 rpm
Desired Speed Input Arrangement CAN Input
Fuel Enable Input Configuration Switch to Ground
Critical Override Switch Installed Not Installed
Emergency Shutdown Override Input Switch to Ground
Configuration
Governor Gain Factor #1 13107
Governor Minimum Stability Factor #1 1049
Governor Maximum Stability Factor #1 2097
Full Load Setting (FLS) 10
Full Torque Setting (FTS) 1
Customer Password 1 ********
Customer Password 2 ********
Total Tattletales 1

Injector Trim Calibration - 2506-E15 (MGBF5027U10755X)


Injector Serial Number File Version
Injector1 000000005A5266489619 0
Injector2 000000005A52665122BE 0
Injector3 000000005A526652081F 0
Injector4 000000005A526648910C 0
Injector5 000000005A5266511281 0
Injector6 000000005A526651179A 0

Monitoring System - 2506-E15 (MGBF5027U10755X)


Description State Trip Point Delay Time
Engine Overspeed
Least Severe (1) On 2000 rpm 1 sec
Most Severe (3) Always On 2140 rpm 0 sec
Action Alert (2) Always On 2050 rpm 0 sec
High Boost Pressure
Action Alert (2) Always On None 5 sec
High Boost Pressure
Least Severe (1) On 300.0 kPa 60 sec
High Engine Coolant
Temperature
Least Severe (1) On 104 Deg C 60 sec
Most Severe (3) Always On 108 Deg C 10 sec
Action Alert (2) Always On 105 Deg C 10 sec
High Engine Inlet Air
Temperature
Least Severe (1) On 75.0 Deg C 60 sec
Action Alert (2) Always On 78.0 Deg C 10 sec
High Fuel Temperature
Least Severe (1) On 60.0 Deg C 60 sec
Action Alert (2) Always On 68.0 Deg C 60 sec
Low Engine Oil
Pressure
Most Severe (3) Always On None 2 sec
Action Alert (2) Always On None 2 sec
Low Engine Oil
Pressure
Least Severe (1) On 300 kPa 60 sec