Proximity Transducers, Seismic Sensors and Accessories: Case Expansion Transducer TM0602

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Proximity Transducers, Seismic Sensors and Accessories

Case Expansion Transducer TM0602

For steam turbine applications, the relative case


expansion due to thermal effect should be monitored.
Case expansion is the thermal growth of the machine
case as it expands during machine start-up and on-line
operations. The TM0602 is typically mounted on the
foundation at the opposite end from where the turbine
casing is attached to the foundation. The case expansion Environmental and Physical
transducer system provides information on the growth of
Temperature Range: -18℃ to +71℃ (0℉ to +160℉)
the machine case relative to the foundation.
Storage Temperature: -54℃ to +93℃(-65℉to +200℉)
Dimensions: See drawing
LVDTs (linear variable differential transformers) are used
Weight: 4 kilograms
to measure the case expansion. Three different linear
Case Material: Stainless steel
ranges are available: 25mm (1.0”), 50mm (2.0”) and
100mm (4.0”). The case expansion transducer assembly
consists of an LVDT that is housed in a weatherproof Order Information
protective enclosure.
TM0602-AXX
Specifications AXX: Linear range
A01: 25mm (1.0”)
A02: 50mm (2.0”)
Electrical
A03: 100mm (4.0”)
Sensitivity:
Probe exposure Thread length
TM0602-A01: 0.4V/mm (10V/in) X Y
(A) (B)
TM0602-A02: 0.2V/mm (5V/in) A01 290mm 246mm 40mm 75mm
TM0602-A03: 0.1V/mm (2.5V/in) (11.4”) (9.7”) (1.6”) (3”)
Linearity: +/- 0.5% full-scale A02 340mm 296mm 60mm 75mm
(13.4”) (11.7”) (2.4”) (3”)
Stability: 0.125% full-scale
A03 520mm 476mm 115mm 130mm
(20.5”) (18.7”) (4.5”) (5.1”)
84 [3.307]

A B
PVTVM
TM0602-A02
www.pvtvm.com

Y
R4
97 [3.82]
116 [4.57]

97 [3.82]

22 [0.87]
5 [0.20]
22 [0.87] R4
.2
5
2- 8.5

44 [1.73]
44 [1.73]

PVTVM [email protected] ● www.pvtvm.com