Ce Testing Report PDF
Ce Testing Report PDF
Ce Testing Report PDF
TEST REPORT
IEC 60598-2-3
Luminaires
Part 2: Particular requirements
Section 3: Luminaires for road and street lighting
Test specification:
Standard ....................................: IEC 60598-2-3:2002, AMD1:2011 used in conjunction with
IEC 60598-1:2014, AMD1:2017
Test procedure ...........................: CE LVD
Non-standard test method...........: N/A
Test Report Form No. ..................: IEC60598_2_3L
Test Report Form(s) Originator ....: Intertek Semko AB
Master TRF.................................: Dated 2018-03-09
Copyright © 2018 IEC System of Conformity Assessment Schemes for Electrotechnical
Equipment and Components (IECEE System). All rights reserved.
This publication may be reproduced in whole or in part for non -commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for da mages resulting
from the reader's interpretation of the reproduced material due to its placement and context .
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the
CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory
and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
General disclaimer:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing
Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,
responsible for this Test Report.
Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):
According to the standard EN 62493:2015, the DUT belongs to unintentional radiating part of lighting
equipment. Due to the reason that the DUT fulfils the inherent-compliance condition "It is a LED-light-
source technology", the DUT is deemed to comply with requirements of this standard without testing.
Summary of testing:
Remark: The height of graphical symbols shall not be less than 5mm.
The height of letters and numbers shall not be less than 2 mm.
The height of symbol of WEEE shall not be less than 7 mm.
The minimum height of ‘caution, risk of electric shock’ symbol shall be 15mm.
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) ......................: ZHEJIANG HONGYUAN LAMPS CO., LTD.
NO.18 FENGYI ROAD, YUYAO, ZHEJIANG
315403, P.R.China
Remark:
1. ‘A’, ‘B’, ‘C’, ‘D’, ‘S’, ‘M’ in model name mean different size of enclosure in same series; ‘-S’ means
smooth, with cooling rib inside the metal enclosure; ‘G’ means with glass cover.
2. Three kinds of approved SPD used.
3. NEMA and ZHAGA socket used for dimming.
4. For kinds of LED chips used: XP-G3 / LUXEON 5050 / LUXEON V2 / LUXEON 3030 2D.
b) Weight P
c) Overall dimensions P
d) Maximum projected area if applicable P
e) Cross-sectional area of wires if applicable N/A
f) Suitability for indoors use N/A
g) Dimensions of the compartment N/A
h) Torque setting to be applied to bolts or screws P
i) Maximum mounting height P
** Insulation type: B – Basic; S – Supplementary; R – Reinforced. See also IEC 60598-1 Annex M.
3.15 P
TABLE: Ball Pressure Test of Thermoplastics
(13.2.1)
Allowed impression diameter (mm) .................: 2
Object/ Part No./ Material Manufacturer/ Test temperature (C) Impression diameter (mm)
trademark
Plastic LED lens -- 125 0,7
-- -- -- --
-- -- -- --
Supplementary information: N/A
3.15 P
TABLE: Needle-flame test (IEC 60695-11-5)
(13.3.1)
Object/ Part No./ Manufacturer/ Duration of Ignition of Duration of
Material trademark application of test specified layer burning (tb) Verdict
flame (ta); (s) Yes/No (s)
Connector -- 10s No 0s P
Terminal block -- 10s No 0s P
Screwless terminal -- 10s No 0s P
Terminal on LED -- 10s No 2s P
board
Supplementary information: N/A
3.15 P
TABLE: Glow-wire test (IEC 60695-2-11)
(13.3.2)
Glow wire temperature ...................................: 650°C
Object/ Part No./ Manufacturer/ Ignition of Duration of
Material trademark specified layer burning (tb) Verdict
Yes/No (s)
Plastic LED lens -- No 0s P
-- -- -- -- --
-- -- -- -- --
Input: AC 120-
240V, 50/60Hz,
INVENTRONICS TÜV SÜD
Driver for 20- EUC- 0,4A; Output: EN 61347-1
D (HANGZHOU), (N8A 17 06
40W 040S105DVM 1050mA, 21- EN 61347-2-13
INC. 79136 169)
54Vdc, 40W, tc:
90°C
Input: AC 120-
240V, 50/60Hz,
INVENTRONICS TÜV SÜD
Driver for 40- EUC- 0,6A; Output: EN 61347-1
D (HANGZHOU), (N8A 17 06
60W 060S070DVM 700mA, 48- EN 61347-2-13
INC. 79136 169)
120Vdc, 60W, tc:
90°C
Input: AC 100-
240V, 50/60Hz,
INVENTRONICS ENEC
Driver for 60- EUK- 0,91A; Output: EN 61347-1
D (HANGZHOU), (HN
80W 075S105DV 1,05A, 36- EN 61347-2-13
INC. 69257105)
107Vdc, 75W, tc:
90°C
Input: AC 100-
240V, 50/60Hz,
INVENTRONICS ENEC
Driver for 80- EUK- 1,13A; Output: EN 61347-1
D (HANGZHOU), (HN
100W 096S105DV 1,05A, 48- EN 61347-2-13
INC. 69258246)
137Vdc, 96W, tc:
90°C
Input: AC 100-
240V, 50/60Hz,
INVENTRONICS ENEC
Driver for 100- EUK- 1,65A; Output: EN 61347-1
D (HANGZHOU), (HN
150W 150S105DV 1,05A, 75- EN 61347-2-13
INC. 69257218)
214Vdc, 150W,
tc: 90°C
Input: AC 100-
240V, 50/60Hz,
INVENTRONICS ENEC
Driver for 150- EUK- 2,25A; Output: EN 61347-1
D (HANGZHOU), (HN
200W 200S105DV 1,05A, 95- EN 61347-2-13
INC. 69257905)
286Vdc, 200W,
tc: 90°C
Input: AC 100-
240V, 50/60Hz,
INVENTRONICS ENEC
Driver for 200- EUK- 2,9A; Output: EN 61347-1
D (HANGZHOU), (HN
240W 240S105DV 1,05A, 114- EN 61347-2-13
INC. 69257905)
343Vdc, 240W,
tc: 90°C
Input: AC 100-
240V, 50/60Hz,
INVENTRONICS TÜV
Driver for 240- EUD- 4,0A; Output: EN 61347-1
D (HANGZHOU), (R
320W 320S150DV 1500mA, 107- EN 61347-2-13
INC. 50370369)
305Vdc, 320W,
tc: 89°C
Input: AC 100-
277V, 50/60Hz,
Shenzhen Sosen TÜV SÜD
Driver for 20- 0,35A; Output: EN 61347-1
D Electronics Co., SS-25H-54 (B 18 04
25W 0,32-0,6A, 32- EN 61347-2-13
Ltd. 83805 046)
54Vdc, 25W,
tc:85°C
Input: AC 100-
277V, 50/60Hz,
Shenzhen Sosen TÜV SÜD
Driver for 25- 0,5A; Output: EN 61347-1
D Electronics Co., SS-35H-54 (B 18 03
35W 0,45-0,85A, 36- EN 61347-2-13
Ltd. 83805 038)
54Vdc, 36W,
tc:90°C
Input: AC 100-
Shenzhen Sosen 277V, 50/60Hz, TÜV SÜD
Driver for 35- EN 61347-1
D Electronics Co., SS-60H-54 1,0A; Output: 0,8- (B 18 03
65W EN 61347-2-13
Ltd. 1,45A, 32-54Vdc, 83805 044)
60W, tc:90°C
Input: AC 200-
240V, 50/60Hz,
Shenzhen Sosen TÜV SÜD
Driver for 60- 1,0A; Output: 0,5- EN 61347-1
D Electronics Co., SS-75E-108 (B 17 11
80W 1,05A, 54- EN 61347-2-13
Ltd. 83805 034)
108Vdc, 75W,
tc:85°C
Input: AC 200-
240V, 50/60Hz,
Shenzhen Sosen TÜV SÜD
Driver for 80- 1,4A; Output: 0,5- EN 61347-1
D Electronics Co., SS-100E-143 (B 17 11
100W 1,05A, 72- EN 61347-2-13
Ltd. 83805 034)
143Vdc, 96W,
tc:85°C
Input: AC 200-
240V, 50/60Hz,
Shenzhen Sosen TÜV SÜD
Driver for 100- 2,0A; Output: 0,5- EN 61347-1
D Electronics Co., SS-150E-215 (B 17 11
150W 1,05A, 108- EN 61347-2-13
Ltd. 83805 034)
215Vdc, 150W,
tc:85°C
Input: AC 100-
240V, 50/60Hz,
Shenzhen Sosen TÜV SÜD
Driver for 150- 2,4A; Output: 0,5- EN 61347-1
D Electronics Co., SS-200E-285 (B 17 11
200W 1,05A, 142- EN 61347-2-13
Ltd. 83805 034)
285Vdc, 200W,
tc:85°C
Input: AC 220-
OT 20/170- DIN EN 61347-
240V, 50/60Hz;
Driver for 10- 240/1A0 1 VDE
D OSRAM GmbH Output: 0,2-
20W 4DIMLT2 G2 DIN EN 61347- (40043863)
1,05A, Max.
CE 2-13
60Vdc, tc:75°C
Input: AC 220-
OT 40/170- DIN EN 61347-
240V, 50/60Hz;
Driver for 20- 240/1A0 1 VDE
D OSRAM GmbH Output: 0,2-
40W 4DIMLT2 G2 DIN EN 61347- (40043863)
1,05A, Max.
CE 2-13
60Vdc, tc:80°C
Input: AC 220-
OT 75/170- DIN EN 61347-
240V, 50/60Hz;
Driver for 40- 240/1A0 1 VDE
D OSRAM GmbH Output: 0,2-
80W 4DIMLT2 G2 DIN EN 61347- (40043863)
1,05A, Max.
CE 2-13
120Vdc, tc:85°C
Input: AC 220-
OT 110/170- DIN EN 61347-
240V, 50/60Hz;
Driver for 80- 240/1A0 1 VDE
D OSRAM GmbH Output: 0,2-
120W 4DIMLT2 G2 DIN EN 61347- (40043863)
1,05A, Max.
CE 2-13
250Vdc, tc:85°C
Input: AC 220-
240V, 50/60Hz, DIN EN 61347-
OT 165/170-
Driver for 120- 0,5A; Output: 0,3- 1 VDE
D OSRAM GmbH 240/1A0
180W 1,05A, DIN EN 61347- (40043863)
4DIMLT2 E
Max.300Vdc, 2-13
tc:85°C
Input: AC 220-
240V, 50/60Hz,
OT 50/120-
Driver for 20- 0,5A; Output: EN 61347-1 ENEC-
D OSRAM SPA 277/800
55W 0,35-0,8A, 30- EN 61347-2-13 01112-A1
2DIMLT2 P
115Vdc, 50W,
tc:85°C
Input: AC 220-
240V, 50/60Hz,
OT 100/120-
Driver for 60- 0,875A; Output: EN 61347-1 ENEC-
D OSRAM SPA 277/800
100W 0,35-0,8A, 50- EN 61347-2-13 01232-A1
2DIMLT2 P
186Vdc, 100W,
tc:85°C
Supplementary information:
1)
Provided evidence ensures the agreed level of compliance. See OD-CB2039.
The codes above have the following meaning:
A - The component is replaceable with another one, also certified, with equivalent characteristics
B - The component is replaceable if authorised by the test house
C - Integrated component tested together with the appliance
D - Alternative component
(15.6.3.1) N/A
TABLE: Contact resistance test / Heating tests
(15.6.3.2)
Voltage drop (mV) after 1 h
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV) -- -- -- -- -- -- -- -- -- --
Voltage drop of two inseparable joints N/A
Voltage drop after 10th alt. 25th cycle N/A
Max. allowed voltage drop (mV) .............. :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV) -- -- -- -- -- -- -- -- -- --
Voltage drop after 50th alt. 100th cycle N/A
Max. allowed voltage drop (mV) .............. : -
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV) -- -- -- -- -- -- -- -- -- --
Continued ageing: voltage drop after 10th alt. 25th cycle N/A
Max. allowed voltage drop (mV) .............. :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV) -- -- -- -- -- -- -- -- -- --
Continued ageing: voltage drop after 50th alt. 100th cycle N/A
Max. allowed voltage drop (mV) .............. :
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV) -- -- -- -- -- -- -- -- -- --
TEST REPORT
IEC 62471
Photobiological safety of lamps and lamp systems
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description........................... : LED STREET LIGHT
Trade Mark .............................................. :
Spectral Distribution
HYDD-LED15/320W(CREE XP-G3):
HYDD-LED15/320W(LUXEON 5050):
HYDD-LED15/320W(LUXEON V2):
4 EXPOSURE LIMITS P
4.1 General P
The exposure limits in this standard is not less than 0,01 P
ms and not more than any 8-hour period and should be
used as guides in the control of exposure
Detailed spectral data of a light source are generally P
required only if the luminance of the source exceeds 10 4 see clause 4.3
cd.m -2
4.3 Hazard exposure limits P
4.3.1 Actinic UV hazard exposure limit for the skin and eye N/A
The exposure limit for effective radiant exposure is 30 N/A
J.m -2 within any 8-hour period
To protect against injury of the eye or skin from ultra- N/A
violet radiation exposure produced by a broadband
source, the effective integrated spectral irradiance ,
ES, of the light source shall not exceed the levels de-
fined by:
N/A
P
for t > 10 4 s
4.3.4 Retinal blue light hazard exposure limit - small source N/A
Thus the spectral irradiance at the eye E λ, weighted N/A
against the blue-light hazard function B(λ) shall not see table 4.2
exceed the levels defined by:
N/A
for t ≤ 100 s
N/A
for t > 100 s
4.3.6 Retinal thermal hazard exposure limit – weak visual stimulus N/A
For an infrared heat lamp or any near-infrared source N/A
where a weak visual stimulus is inadequate to activate
the aversion response, the near infrared (780 nm to
1400 nm) radiance, L IR, as viewed by the eye for ex-
posure times greater than 10 s shall be limited to:
N/A
t > 10 s
4.3.7 Infrared radiation hazard exposure limits for the eye N/A
The avoid thermal injury of the cornea and possible N/A
delayed effects upon the lens of the eye (cataracto-
genesis), ocular exposure to infrared radiation, E IR, over
the wavelength range 780 nm to 3000 nm, for tim es less
than 1000 s, shall not exceed:
N/A
t ≤ 1000 s
6 LAMP CLASSIFICATION P
For the purposes of this standard it was decided that the see table 6.1 P
values shall be reported as follows:
– for lamps intended for general lighting service, the N/A
hazard values shall be reported as either irradiance
or radiance values at a distance which produces an
illuminance of 500 lux, but not at a distance less
than 200 mm
– for all other light sources, including pulsed lamp P
sources, the hazard values shall be reported at a
distance of 200 mm
6.1 Continuous wave lamps P
6.1.1 Exempt Group N/A
In the except group are lamps, which does not pose any N/A
photobiological hazard. The requirement is met by any
lamp that does not pose:
Table 4.1 Spectral weighting function for assessing ultraviolet hazards for skin and eye P
Wavelength 1
UV hazard function Wavelength
λ, nm SUV(λ) λ, nm UV hazard function SUV(λ)
200 0,030 313* 0,006
205 0,051 315 0,003
210 0,075 316 0,0024
215 0,095 317 0,0020
220 0,120 318 0,0016
225 0,150 319 0,0012
230 0,190 320 0,0010
235 0,240 322 0,00067
240 0,300 323 0,00054
245 0,360 325 0,00050
250 0,430 328 0,00044
254* 0,500 330 0,00041
255 0,520 333* 0,00037
260 0,650 335 0,00034
265 0,810 340 0,00028
270 1,000 345 0,00024
275 0,960 350 0,00020
280* 0,880 355 0,00016
285 0,770 360 0,00013
290 0,640 365* 0,00011
295 0,540 370 0,000093
297* 0,460 375 0,000077
300 0,300 380 0,000064
303* 0,120 385 0,000053
305 0,060 390 0,000044
308 0,026 395 0,000036
310 0,015 400 0,000030
1
Wavelengths chosen are representative: other values should be obtained by logarithmic interpolation at in-
termediate wavelengths.
* Emission lines of a mercury discharge spectrum.
Table 4.2 Spectral weighting functions for assessing retinal hazards from broadband optical P
sources
Wavelength Blue-light hazard function Burn hazard function
nm B (λ) R (λ)
300 0,01
305 0,01
310 0,01
315 0,01
320 0,01
325 0,01
330 0,01
335 0,01
340 0,01
345 0,01
350 0,01
355 0,01
360 0,01
365 0,01
370 0,01
375 0,01
380 0,01 0,1
385 0,013 0,13
390 0,025 0,25
395 0,05 0,5
400 0,10 1,0
405 0,20 2,0
410 0,40 4,0
415 0,80 8,0
420 0,90 9,0
425 0,95 9,5
430 0,98 9,8
435 1,00 10,0
440 1,00 10,0
445 0,97 9,7
450 0,94 9,4
455 0,90 9,0
460 0,80 8,0
465 0,70 7,0
470 0,62 6,2
475 0,55 5,5
480 0,45 4,5
485 0,40 4,0
490 0,22 2,2
495 0,16 1,6
500-600 10[(450-λ)/50] 1,0
600-700 0,001 1,0
700-1050 10[(700-λ)/500]
1050-1150 0,2
1150-1200 0,2 .100,02(1150-λ)
1200-1400 0,02
Table 5.4 Summary of the ELs for the surface of the skin or cornea (irradiance based values) P
Wavelength Exposure Limiting EL in terms of con-
Hazard
Relevant equation range duration aperture stant irradiance
Name
nm sec rad (deg) W•m-2
Actinic UV skin
& eye ES = ∑Eλ • S(λ) • ∆λ 200 – 400 < 30000 1,4 (80) 30/t
≤1000 10000/t
Eye UV-A EUVA = ∑Eλ • ∆λ 315 – 400 1,4 (80)
>1000 10
Blue-light small EB = ∑Eλ • B(λ) • ∆λ ≤100 100/t
source 300 – 700 < 0,011
>100 1,0
≤1000 18000/t 0,75
Eye IR EIR = ∑Eλ • ∆λ 780 –3000 1,4 (80)
>1000 100
Table 5.5 Summary of the ELs for the retina (radiance based values) P
Wavelength Exposure Field of view EL in terms of
Hazard Name Relevant equation range duration constant radiance
radians
nm sec W•m-2•sr-1)
0,25 – 10 0,011•√(t/10) 10 6/t
10-100 0,011 10 6/t
Blue light LB = ∑L λ • B(λ) • ∆λ 300 – 700
100-10000 0,0011•√t 10 6/t
≥ 10000 0,1 100
Retinal < 0,25 0,0017 50000/(α•t 0,25)
thermal LR = ∑L λ • R(λ) • ∆λ 380 – 1400
0,25 – 10 0,011•√(t/10) 50000/(α•t 0,25)
Retinal
thermal
LIR = ∑L λ • R(λ) • ∆λ 780 – 1400 > 10 0,011 6000/α
(weak visual
stimulus)
Table 6.1 Emission limits for risk groups of continuous wave lamps HYDD-LED15/320W(CREE XP-G3) P
Emission Measurement
Risk Action Symbol Units Exempt Low risk Mod risk
spectrum
Limit Result Limit Result Limit Result
Blue light B(λ) LB W•m -2•sr-1 100 161,4 10000 4270 4000000 --
Blue light,
B(λ) EB W•m -2 1 -- 1,0 -- 400 --
small source
Retinal 4,952x104
R(λ) LR W•m -2•sr-1 28000/α (α=45,14mr 28000/α -- 71000/α --
thermal
ad)
Retinal
thermal, R(λ) LIR W•m -2•sr-1 6000/α 6000/α 6000/α
weak visual -- -- --
stimulus**
IR radiation,
EIR W•m -2 100 -- 570 -- 3200 --
eye
* Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian.
** Involves evaluation of non-GLS source
Table 6.1 Emission limits for risk groups of continuous wave lamps HYDD-LED15/320W(LUXEON 5050) P
Emission Measurement
Risk Action Symbol Units Exempt Low risk Mod risk
spectrum
Limit Result Limit Result Limit Result
Blue light B(λ) LB W•m -2•sr-1 100 191,6 10000 2628 4000000 --
Blue light,
B(λ) EB W•m -2 1 -- 1,0 -- 400 --
small source
Retinal 3,196x104
R(λ) LR W•m -2•sr-1 28000/α (α=38,35mr 28000/α -- 71000/α --
thermal
ad)
Retinal
thermal, R(λ) LIR W•m -2•sr-1 6000/α 6000/α 6000/α
weak visual -- -- --
stimulus**
IR radiation,
EIR W•m -2 100 -- 570 -- 3200 --
eye
* Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian.
** Involves evaluation of non-GLS source
Table 6.1 Emission limits for risk groups of continuous wave lamps HYDD-LED15/320W(LUXEON V2) P
Emission Measurement
Action
Risk Symbol Units Exempt Low risk Mod risk
spectrum
Limit Result Limit Result Limit Result
Blue light,
B(λ) EB W•m-2 1,0* -- 1,0 -- 400 --
small source
Retinal 3,537x104
R(λ) LR W•m-2•sr-1 28000/α (α=53,35mr 28000/α -- 71000/α --
thermal
ad)
Retinal
thermal,
R(λ) LIR W•m-2•sr-1 6000/α -- 6000/α -- 6000/α --
weak visual
stimulus**
IR radiation,
EIR W•m-2 100 -- 570 -- 3200 --
eye
* Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian.
** Involves evaluation of non-GLS source
Table 6.1 Emission limits for risk groups of continuous wave lamps HYDD-LED15/320W(LUXEON 3030 2D) P
Emission Measurement
Action
Risk Symbol Units Exempt Low risk Mod risk
spectrum
Limit Result Limit Result Limit Result
Blue light,
B(λ) EB W•m-2 1,0* -- 1,0 -- 400 --
small source
Retinal 7,209x104
R(λ) LR W•m-2•sr-1 28000/α (α=25,66mr 28000/α -- 71000/α --
thermal
ad)
Retinal
thermal,
R(λ) LIR W•m-2•sr-1 6000/α -- 6000/α -- 6000/α --
weak visual
stimulus**
IR radiation,
EIR W•m-2 100 -- 570 -- 3200 --
eye
* Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian.
** Involves evaluation of non-GLS source
Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) P
HYDD-LED15/320W(CREE XP-G3)
Emission Measurement
Action
Risk Symbol Units Exempt Low risk Mod risk
spectrum
Limit Result Limit Result Limit Result
Blue light B(λ) LB W•m -2•sr-1 100 161,3 10000 4267 4000000 --
Blue light,
B(λ) EB W•m -2 0,01* -- 1,0 -- 400 --
small source
Retinal 4,952x104
R(λ) LR W•m -2•sr-1 28000/α 28000/α -- 71000/α --
thermal (α=45,14mrad)
545000
--
Retinal 0,0017≤ α ≤
thermal, R(λ) LIR W•m -2•sr-1 0,011
weak visual
stimulus** 6000/α
--
0,011≤ α ≤ 0,1
Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) P
IR radiation,
EIR W•m -2 100 -- 570 -- 3200 --
eye
Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) P
HYDD-LED15/320W(LUXEON 5050)
Emission Measurement
Risk Action Symbol Units Exempt Low risk Mod risk
spectrum
Limit Result Limit Result Limit Result
Blue light B(λ) LB W•m -2•sr-1 100 191,2 10000 2622 4000000 --
Blue light,
B(λ) EB W•m -2 0,01* -- 1,0 -- 400 --
small source
Retinal 3,196x104
R(λ) LR W•m -2•sr-1 28000/α 28000/α -- 71000/α --
thermal (α=38,35mrad)
545000
Retinal
thermal, R(λ) LIR W•m -2•sr-1 0,0017≤ α ≤ --
weak visual 0,011
Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) P
stimulus** 6000/α
--
0,011≤ α ≤ 0,1
IR radiation,
EIR W•m -2 100 -- 570 -- 3200 --
eye
Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) P
HYDD-LED15/320W(LUXEON V2)
Emission Measurement
Action
Risk Symbol Units Exempt Low risk Mod risk
spectrum
Limit Result Limit Result Limit Result
Blue light B(λ) LB W•m -2•sr-1 100 116,5 10000 3051 4000000 --
Blue light,
B(λ) EB W•m -2 0,01* -- 1,0 -- 400 --
small source
Retinal 3,537x104
R(λ) LR W•m -2•sr-1 28000/α 28000/α -- 71000/α --
thermal (α=53,35mrad)
Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) P
545000
Retinal 0,0017≤ α ≤ --
thermal, 0,011
R(λ) LIR W•m -2•sr-1
weak visual
stimulus** 6000/α
--
0,011≤ α ≤ 0,1
IR radiation,
EIR W•m -2 100 -- 570 -- 3200 --
eye
Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) P
HYDD-LED15/320W(LUXEON 3030 2D)
Emission Measurement
Action
Risk Symbol Units Exempt Low risk Mod risk
spectrum
Limit Result Limit Result Limit Result
Blue light B(λ) LB W•m -2•sr-1 100 379,3 10000 5977 4000000 --
Table 6.1 Emission limits for risk groups of continuous wave lamps (based on EU Directive 2006/25/EC) P
Blue light,
B(λ) EB W•m -2 0,01* -- 1,0 -- 400 --
small source
545000
--
Retinal 0,0017≤ α ≤
thermal, R(λ) LIR W•m -2•sr-1 0,011
weak visual
stimulus** 6000/α
--
0,011≤ α ≤ 0,1
IR radiation,
EIR W•m -2 100 -- 570 -- 3200 --
eye