The document describes a combined ultrasonic and microwave intrusion detector that detects breakage, intrusion, and motion within a protected area. It details the detector's features such as unprecedented premises protection, stable operation in different environments, and an innovative method for detecting ultrasonic and microwave signals through Doppler effect analysis. Installation, testing, and adjustment procedures are also outlined.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
58 views2 pages
Patrol-Usm Ver.1 Eng
The document describes a combined ultrasonic and microwave intrusion detector that detects breakage, intrusion, and motion within a protected area. It details the detector's features such as unprecedented premises protection, stable operation in different environments, and an innovative method for detecting ultrasonic and microwave signals through Doppler effect analysis. Installation, testing, and adjustment procedures are also outlined.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
PATROL-USM combined FEATURES ALGORITHM 3.
To activate the alarm, both
PATROL™- USM ultrasonic & microwave · UNPRECEDENTED PREMISES Dual-technology detector ultrasonic and microwave signals must be successively detector determines PROTECTION incorporates two physical sensed within a pre- destruction of walls, doors, · STABLE OPERATION IN A WIDE- means for determining determined time period. COMBINED all types of glass and intrusion RANGING TEMPERATURE destruction of walls, doors, ULTRASONIC & MW into the protected area. ENVIRONMENT all types of glass and intrusion Figure 1 INTRUSION DETECTOR into the protected area: PATROL-USM with anti-mask · INNOVATIVE METHOD FOR Human Motion Detection DETECTING ULTRASONIC AND registering the change in technology detects any of the MW SIGNALS frequency of ultrasonic and DETECTS BREAKAGE, ultrasonic sensors' masking microwave signals INTRUSION AND MOTION attempts. · DIGITAL SPECTRAL ANALYSIS (Doppler Effect). WITHIN PROTECTED AREA OF ULTRASONIC AND MW FREQUENCIES 1. The Doppler Effect occurs · PULSE-COUNT SELECTION (1-5) when ultrasonic waves, emitted INSTRUCTION continuously by the detector, MANUALS · SEPARATE ADJUSTMENT change their length and FOR BOTH ULTRASONIC AND MW CHANNEL SENSITIVITY frequency when reflecting from different moving objects. · BUILT- IN ANTI- MASK SYSTEM 2. The Doppler Effect occurs · HIGH RFI/EMI PROTECTION when microwaves, emitted by · TAMPER PROTECTION the detector, change their length and frequency when · AUTOMATIC GAIN CONTROL – ADAPTATION TO reflecting from different moving ENVIRONMENTAL CHANGES objects.
1 2 3 4 5
Figure 2 Figure 3 For wiring, use the INSTALLATION DETECTOR
Wall Breakage Detection Glass Breakage Detection designated opening above LIMITATIONS INSTALLATION OPTIONS the detector terminal block. · Do not install the detector 2. Connect the wires in on unstable or vibrating accordance with the scheme. surfaces. · Do not install the detector + 12V - RELAY TAMPER close to curtains, blinds or other items that vibrate with air movement. · Do not install the detector NOTE! close to air conditioners, air blast sources or above heat Several detectors of this type sources. DETECTOR can be installed within the INSTALLATION protected area, at a distance · Do not install the detector of at least 3 meters from each or route power wires and 1. Fix the detector vertically other. alarm loops next to high on solid, flat wall surface. voltage cables The installation height is · Do not install the detector 2 – 2.5 meters. near bells, sirens or For corner installation, use electronic sounders within knockouts located on the the premises where sound- sloping part of the detector pressure level exceeds base. 75dB. 6 7 8 9 10 DETECTOR TESTING If needed, increase the 5. Test the microwave (MW) 6. Replace jumper W2 to 8. Replace the cover - red AND ADJUSTMENT detector ultrasonic channel channel operation. "WORK" position. LED will blink. At the same sensitivity using W4 jumper · Set jumper W2 to "MW time, keep the detector field- 1. Remove the front cover. 7. Select the required number (Ultrasonic Sensitivity). TEST" position. of-view clear, until the LED of pulses (1-5). 2. Set jumper W2 to "US stops blinking – the anti- · Stay for a while to make · Walk into the detector masking function will then TEST" position. Selectable pulse count 1, 2, 3, sure the green LED stops field-of-view. The yellow LED be correctly activated. 4 or 5 provides users with the 3. Connect the power. blinking, which means the should actively respond to your option of optimizing detector detector ultrasonic channel movement. If necessary, 4. Test the ultrasonic channel sensitivity to suit the is configured correctly! increase the detector operation. environment, thus retaining If the green LED keeps blinking, microwave channel sensitivity, reliable performance at all check the premises without using R11 potentiometer · First of all, make sure there times. interferences, as described (Microwave Sensitivity). are no humans or animals above. To adjust pulse count for within the protected area, · Stay for a while to make sure windows are closed; specific operating If necessary, reduce the the yellow LED stops blinking, air-conditioners, fans and environments: excessive ultrasonic channel which means the detector other possible sources of sensitivity using W4 jumper microwave (MW) channel is A. Remove the W3 jumper. air flow are switched off. (Ultrasonic Sensitivity). configured correctly! If the The red LED blinks, indicating yellow LED keeps blinking, that pulse counting has begun. · Walk into the detector field-of-view. The green LED reduce the excessive MW B. Replace jumper W3 during should actively respond to channel sensitivity using pause between LED blinking. your movement. the R11 potentiometer (Microwave Sensitivity). · To operate the detector without light indication, remove the W1 (LED) jumper.
DETECTION ZONE SPECIFICATIONS GSN Electronic Company Ltd. Maximum protected volume: Input voltage:............9 - 16Vdc …………........................ 200m³ warrants the product to be free from defects in materials and TOP VIEW Current consumption Detection angle:…….........170° workmanship under condition of observance of service In standby mode:……….44mА Relay output:………………….. regulations and to be repaired In alarm mode:………….95mА ………..NC; 60V; 120mA; 16Ω or replaced under absence of mechanical damages for a Warm-up period:….……...2sec Tamper output:………NC; 10Ω limited period of five years Operating temperature range: from the date of sale. Anti-mask startup (boot) ………………...–30ºC to +70ºC period:………………...30±5sec Storage temperature range: Alarm period:……...……...3sec ………..............–50ºC to +85ºC Anti-mask alarm activation RFI immunity:…………...30V/m delay:………………….....35sec at a frequency range W2 – Operating mode setting 10MHz – 2GHz Ultrasonic channel operating W3 – Pulse programming jumper frequency:……………....40kHz EMI immunity:…………50000V W4 – Ultrasonic channel Dimensions:………….……….... Microwave channel operating sensitivity adjustment ..........105mm x 50mm x 22mm frequency: ....................24GHz R11 – MW channel sensitivity Weight:……………………...80g adjustment Installation height:……2 - 2.5m P/N: USM0PATUSM_ENG_REV.A