Keypad Programming: (Section 2.5 "Keypad Assignment" On Page 4)
Keypad Programming: (Section 2.5 "Keypad Assignment" On Page 4)
Keypad Programming: (Section 2.5 "Keypad Assignment" On Page 4)
Keypad Programming
[000] Keypad Enrollment (Section 2.5 “Keypad Assignment” on page 4)
NOTE: This must be done at each keypad requiring programming.
[0] Slot [Valid entries are 11-18; i.e. enter [11] for slot 1, [12] for slot 2, etc.]
[1] Function Key 1 Assignment (Valid entries are 00-17)
[2] Function Key 2 Assignment (Valid entries are 00-17)
[3] Function Key 3 Assignment (Valid entries are 00-17)
[4] Function Key 4 Assignment (Valid entries are 00-17)
[5] Function Key 5 Assignment (Valid entries are 00-17)
Function Key Options:
00 Null Key 08 [*][1] Bypass Mode 16 [*][0] Quick Exit
01 For future use 09 [*][2] Trouble Display 17 [*][1] Reactivate Stay/Away’s
02 For future use 10 [*][3] Alarm Memory 18 For future use
03 Stay Arm 11 [*][5] User Programming 19 For future use
04 Away Arm 12 [*][6] User Functions 20 For future use
05 [*][9] No-Entry Arm 13 Command Output #1 [*][7][1] 21 For future use
06 [*][4] Chime On / Off 14 Command Output #2 [*][7][2]
07 [*][6][——][4] System Test 15 For future use
Slot Function Function Function Function Function
Key 1 Key 2 Key 3 Key 4 Key 5
LED Defaults 11 03 04 06 14 16
LCD Defaults 18 03 04 06 14 16
KEYPAD 1 I________I________I I________I I________I I________I I________I I________I
Basic Programming
Zone Definitions
00 Null Zone (Not Used) 10 24 Hour Supervisory Buzzer 20 24 Hour Freeze
01 Delay 1 11 24 Hour Burglary 21 24 Hour Latching Tamper
02 Delay 2 12 24 Hour Holdup 22 Momentary Keyswitch Arm
03 Instant 13 24 Hour Gas 23 Maintained Keyswitch Arm
04 Interior 14 24 Hour Heating (N/C zone) 24 LINKS Answer
05 Interior, Stay/Away 15 24 Hour Medical 25 Interior Delay
06 Delay, Stay/Away 16 24 Hour Panic 87 Delay 24 Hour Fire (Wireless)
07 Delayed 24 Hour Fire (Hardwired) 17 24 Hour Emergency 88 Standard 24 Hour Fire (Wireless)
08 Standard 24 Hour Fire (Hardwired) 18 24 Hour Sprinkler
09 24 Hour Supervisory 19 24 Hour Water
NOTE:Keypads must be installed to use 24-hour Buzzer zones.
NOTE:Keypad zones are assigned in section [020]. Zone Attributes are assigned in sections [101] - [132]. Zone assignment is in
sections [202] - [205].
[001] Zone 1-8 Definitions (Section 5.2 “Zone Programming” on page 15)
Default Default
01 I_______I_______I Zone 1 00 I_______I_______I Zone 5
03 I_______I_______I Zone 2 00 I_______I_______I Zone 6
04 I_______I_______I Zone 3 00 I_______I_______I Zone 7
04 I_______I_______I Zone 4 00 I_______I_______I Zone 8
29
NOTE:Zones 9-32 are only available for wireless zones.
[002] Zone 9-16 Definitions (Section 5.2 “Zone Programming” on page 15)
Default Default
00 I_______I_______I Zone 9 00 I_______I_______I Zone 13
00 I_______I_______I Zone 10 00 I_______I_______I Zone 14
00 I_______I_______I Zone 11 00 I_______I_______I Zone 15
00 I_______I_______I Zone 12 00 I_______I_______I Zone 16
[003] Zone 17-24 Definitions (Section 5.2 “Zone Programming” on page 15)
Default Default
00 I_______I_______I Zone 17 00 I_______I_______I Zone 21
00 I_______I_______I Zone 18 00 I_______I_______I Zone 22
00 I_______I_______I Zone 19 00 I_______I_______I Zone 23
00 I_______I_______I Zone 20 00 I_______I_______I Zone 24
[004] Zone 25-32 Definitions (Section 5.2 “Zone Programming” on page 15)
Default Default
00 I_______I_______I Zone 25 00 I_______I_______I Zone 29
00 I_______I_______I Zone 26 00 I_______I_______I Zone 30
00 I_______I_______I Zone 27 00 I_______I_______I Zone 31
00 I_______I_______I Zone28 00 I_______I_______I Zone 32
[005] System Times
Default Valid entries: [001-255]
030 I_______I_______I_______I Entry Delay 1 (in seconds)(Section 5.18 “Entry/Exit Delay Options” on page 24)
045 I_______I_______I_______I Entry Delay 2 (in seconds)(Section 5.18 “Entry/Exit Delay Options” on page 24)
120 I_______I_______I_______I Exit Delay (in seconds)(Section 5.18 “Entry/Exit Delay Options” on page 24)
004 I_______I_______I_______I Bell Cut-off (in minutes)(Section 5.13 “Bell” on page 22)
[006] Installer’s Code (Section 4.1 “Installer’s Programming” on page 13)
Default
5555 I_______I_______I_______I_______I
[007] Master Code (Section 5.1 “Programming Security Codes” on page 15)
Default
1234 I_______I_______I_______I_______I
[008] Maintenance Code (Section 5.1 “Programming Security Codes” on page 15)
Default
AAAA I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2) (Section 5.11 “PGM Output Options” on page 20)
Programmable Output Options
01 Burglary and Fire Bell Output 14 Ground Start Pulse
02 For future use 15 Remote Operation (DLS-1 Support)
03 Sensor Reset 16 LINKS1000 Support (PGM1 only)
04 For future use 17 Away Armed Status
05 System Armed Status 18 Stay Armed Status
06 Ready To Arm 19 Command Output #1 ([*][7][1])
07 Keypad Buzzer Follow Mode 20 Command Output #2 ([*][7][2])
08 Courtesy Pulse 21 For future use
09 System Trouble Output (with Trouble options) 22 For future use
10 System Event [Strobe (with Event options)] 23 For future use
11 System Tamper (all sources: zones, kpd, modules) 24 For future use
12 TLM and Alarm
13 Kissoff Output
NOTE:Output types [03] and [20] cannot be used together on the same system.
Default Default
19 I_______I_______I PGM 1 10 I_______I_______I PGM 2 Program PGM Option Attributes in sections [141] & [142].
30
P r o g r a m m i n g W o r k s h e e t s
[012] Keypad Lockout Options (Section 5.21 “Keypad Lockout Options” on page 24)
NOTE:If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000 I_______I_______I_______I Number of Invalid Codes Before Lockout (001-255 codes)
000 I_______I_______I_______I Lockout Duration (001-255 minutes)
[013] First System Option Code
Default Option ON Off Section Page #
OFF I________I 1 Normally Closed Loops End-of-Line Resistors 2.8 5
OFF I________I 2 Double End-of-Line Resistors Single End-of-Line Resistors 2.8 5
ON* I________I 3 Panel shows all troubles when armed Panel shows only Fire troubles when armed 3.4 8
OFF I________I 4 Tampers/Faults do not show as open Tampers/Faults show as open 3.4 8
OFF I________I 5 For future use
ON I________I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled 5.18 24
ON I________I 7 Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown 5.20 24
OFF I________I 8 Temporal Three Fire Signal Enabled** Standard Pulsed Fire Signal 5.13 22
* Option 3 must be OFF if LCD keypads older than v2.0 are used.
**The Temporal Three Fire Signal option must be used for UL Household Fire installations.
[014] Second System Option Code
Default Option ON Off Section Page #
OFF I________I 1 Arm / Disarm Bell Squawk enabled Arm / Disarm Bell Squawk disabled 5.17 23
OFF I________I 2 Bell Squawk During Auto Arm No Bell Squawk During Auto Arm 5.18 24
OFF I________I 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay 5.18 24
OFF I________I 4 Bell Squawk On Entry Delay No Bell Squawk On Entry Delay 5.18 24
OFF I________I 5 Bell Squawk On Trouble No Bell Squawk On Trouble 3.4 8
ON I________I 6 Audible Exit with Urgency Silent Exit Delay 5.18 24
OFF I________I 7 Exit Delay Termination Enabled Exit Delay Termination Disabled 5.18 24
OFF I________I 8 Fire Bell is Continuous Fire Bell Follows Bell Cut-off 5.13 22
[015] Third System Option Code
Default Option ON Off Section Page #
ON I________I 1 Fire Keys Enabled Fire Keys Disabled 5.16 23
OFF I________I 2 Panic Keys Audible (Bell / Beeps) Panic Keys Silent 5.16 23
OFF I________I 3 Quick Exit Enabled Quick Exit Disabled 3.4 8
ON* I________I 4 Quick Arming Enabled Quick Arming Dis. / Function keys Req. Code 3.4 8
OFF I________I 5 Code Required For Bypassing No Code Required 3.4 8
OFF I________I 6 Master Code Not Changeable Master Code Changeable 5.1 15
ON I________I 7 TLM Enabled TLM Disabled 5.12 22
OFF I________I 8 TLM Audible (Bell) When Armed TLM Trouble Beeps When Armed 5.12 22
* When using a PC5132 version 2.1 or older with WLS909 Wireless Keys, option [4] must be ON for the Arm button to work.
[016] Fourth System Option Code
Default Option ON Off Section Page #
ON I________I 1 AC Trouble Displayed AC Trouble Not Displayed 3.4 8
OFF I________I 2 Trouble Light Flashes if AC Fails Trouble Light Does Not Follow AC Status 3.4 8
OFF I________I 3 Blank Keypad When Not Used Keypad Active Always 5.22 24
OFF I________I 4 Code Required to Remove Kypd BlankingNo Code Required 5.22 24
ON I________I 5 Keypad Backlighting is enabled Keypad Backlighting is disabled 5.23 25
OFF I________I 6 Power Save Mode enabled Power Save Mode disabled 5.22 24
OFF I________I 7 Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed 5.17 23
OFF I________I 8 Keypad Tampers enabled Keypad Tampers disabled 5.25 25
31
[017] Fifth System Option Code
Default Option ON Off Section Page #
ON I________I 1 WLS Key Does Not Use Access Codes* WLS Key Uses Access Codes 5.17 23
OFF I________I 2-7 For future use
OFF I________I 8 Squawk on Away Arming/Disarming OnlyBell Squawk on all Arming/Disarming 5.17 23
*This option must be enabled when using a PC5132 v2.1 or earlier.
32
P r o g r a m m i n g W o r k s h e e t s
33
[115] 15 ( ) I________I I________| I________| I________| I________| I________| I________| I________I
PGM Output Attributes (Section 5.11 “PGM Output Options” on page 20)
Program only the following attributes for the PGM options listed. All others will be ignored. PGM options are programmed in [009].
PGM Attribute Defaults (Y = Attribute ON; N = Attribute OFF):
Attribute: 1 2 3 4 5
ON Output enabled — True Output Follows Timer Code Req.
Attribute: 1 2 3 4 5 6 7 8
PGM Option
ON Serv. req. AC Fail TLM Fault FTC Zone Fault Zone Tmp. Zn. Low Bat. Loss of Clock
OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled
[09] System Trouble Y Y Y Y Y Y Y Y
ON Burg. Evnt. Fire Evnt. Panic Evnt. Med. Evnt. Supv. Evnt. Priority Evnt. Holdup Evnt. Follows Timer*
OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Latched
[10] System Event Y Y Y Y Y Y Y N
*If attribute [8] is turned ON, attributes [1-7] must also be turned ON.
34
P r o g r a m m i n g W o r k s h e e t s
[160] Maximum Dialing Attempts to Each Telephone Number (Section 5.5 “Communicator – Dialing” on page 17)
Default: 008 I_______I_______I_______I Valid entries are 001-015 attempts (do not enter 000).
[161] Post Dial Wait for Handshake (All Formats) (Section 5.5 “Communicator – Dialing” on page 17)
Default: 040 I_______I_______I_______I Valid entries are 001-255 seconds
[164] PGM Output Timer (Section 5.5 “Communicator – Dialing” on page 17)
Default: 005 I_______I_______I_______I Valid entries are 001-255 seconds
[202] Zone Assignments 01-08 (Section 5.2 “Zone Programming” on page 15)
Program zone definitions in sections [001] - [004] and zone attributes in sections [101] - [132]. Program keypad zone assignments
in section [020].
NOTE:Any zones not used on the system should be disabled in this section. Disabled wireless zones should have a blank serial
number (i.e. [000000]).
Zones 1-8: Default = ON; Zones 9-32: Default = OFF
Section Option: 1 2 3 4 5 6 7 8
[202] Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8
I______________I I______________I I______________I I______________I I______________I I______________I I______________I I______________I
Communicator Programming
NOTE: For sections [301] to [353], the content of every section by default is [F].
[301] First Telephone Number (32 Digits) (Section 5.7 “Communicator – Telephone Numbers” on page 17)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[302] Second Telephone Number (32 Digits) (Section 5.7 “Communicator – Telephone Numbers” on page 17)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[303] Third Telephone Number (32 Digits) (Section 5.7 “Communicator – Telephone Numbers” on page 17)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[310] First/Third Telephone Number Account Code (Section 5.6 “Communicator – Account Numbers” on page 17)
I_______I_______I_______I_______I
[311] Second Telephone Number Account Code (Section 5.6 “Communicator – Account Numbers” on page 17)
I_______I_______I_______I_______I
Alarm Reporting Codes, Zones 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
Section
[320] Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8
I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I
35
Alarm Restoral Reporting Codes, Zones 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
Section
[324] Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8
I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I
[328] Miscellaneous Alarm Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
I_______I_______I 1. Duress Alarm I_______I_______I 4. Zone Expander Supervisory Alarm
I_______I_______I 2. Opening After Alarm I_______I_______I 5. Zone Expander Supervisory Restoral
I_______I_______I 3. Recent Closing I_______I_______I 6. Cross Zone Police Code Alarm
[329] Priority Alarm and Restoral (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
I_______I_______I 1. Keypad Fire Alarm I_______I_______I 5. Keypad Fire Restoral
I_______I_______I 2. Keypad Auxiliary Alarm I_______I_______I 6. Keypad Auxiliary Restoral
I_______I_______I 3. Keypad Panic Alarm I_______I_______I 7. Keypad Panic Restoral
I_______I_______I 4. For future use I_______I_______I 8. For future use
Tamper Reporting Codes, Zones 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
Section
[330] Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8
I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I
Tamper Restoral Reporting Codes, Zones 1-8 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
Section
[334] Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8
I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I
[338] Miscellaneous Tamper Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
I_______I_______I 1. General System Tamper
36
P r o g r a m m i n g W o r k s h e e t s
Closing (Arming) Reporting Codes, Access Codes 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
Section
[339] Code 1 Code 2 Code 3 Code 4 Code 5 Code 6 Code 7 Code 8
I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I
*The LINKS Test Transmission Code must be programmed as “00” for the LINKS Test Transmission to be disabled.
37
[353] Wireless Maintenance Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)
I_______I_______I 1. Wireless Device Low Battery Alarm I_______I_______I 2. Wireless Device Low Battery Restore
[360] Communicator Format Options (Section 5.9 “Communicator – Reporting Formats” on page 19)
NOTE:The Third telephone number follows the format of the First telephone number.
Default
02 I_______I_______I 1st/3rd Telephone Number
02 I_______I_______I 2nd Telephone Number
01 20 BPS, 1400 HZ handshake 04 SIA FSK
02 20 BPS, 2300 HZ handshake 05 Pager
03 DTMF CONTACT ID
[361] Alarm/Restore Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
Default Option ON OFF
ON I_______I 1 1st Telephone Number Disabled
OFF I_______I 2 2nd Telephone Number Disabled
OFF I_______I 3 1st Telephone Number (via LINKS) Disabled
OFF I_______I 4 2nd Telephone Number (via LINKS) Disabled
OFF I_______I 5-8 For future use
[363] Tamper/Restore Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
Default Option ON OFF
ON I________I 1 1st Telephone Number Disabled
OFF I________I 2 2nd Telephone Number Disabled
OFF I________I 3 1st Telephone Number (via LINKS) Disabled
OFF I________I 4 2nd Telephone Number (via LINKS) Disabled
OFF I________I 5-8 For future use
[365] Opening/Closing Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
Default Option ON OFF
ON I________I 1 1st Telephone Number Disabled
OFF I________I 2 2nd Telephone Number Disabled
OFF I________I 3 1st Telephone Number (via LINKS) Disabled
OFF I________I 4 2nd Telephone Number (via LINKS) Disabled
OFF I________I 5-8 For future use
[367] System Maintenance Alarm/Restore Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
Default Option ON OFF
ON I________I 1 1st Telephone Number Disabled
OFF I________I 2 2nd Telephone Number Disabled
OFF I________I 3 1st Telephone Number (via LINKS) Disabled
OFF I________I 4 2nd Telephone Number (via LINKS) Disabled
OFF I________I 5-8 For future use
[368] System Test Transmissions Communicator Call Directions (Section 5.5 “Communicator – Dialing” on page 17)
Default Option ON OFF
ON I________I 1 1st Telephone Number Disabled
OFF I________I 2 2nd Telephone Number Disabled
OFF I________I 3 1st Telephone Number (via LINKS) Disabled
OFF I________I 4 2nd Telephone Number (via LINKS) Disabled
OFF I________I 5-8 For future use
NOTE:The LINKS1000 backup call directions will only back up their respective telephone numbers.
38
P r o g r a m m i n g W o r k s h e e t s
39
Downloading Options
[401] First Downloading Option Code (Section 5.10 “Downloading” on page 20)
Default Option ON Off
OFF I_______I 1 Answering machine/double call enabledAnswering machine/double call disabled
ON I_______I 2 User Can Enable DLS Window User Cannot Enable DLS Window
OFF I_______I 3 Call-Back Enabled Call-Back Disabled
OFF I_______I 4 User-initiated call-up enabled User-initiated call-up disabled
OFF I_______I 5-8 For future use
[402] Downloading Computer’s Telephone Number (32 Digits) (Section 5.10 “Downloading” on page 20)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
International Programming
[701] First International Options Code
Default Option ON Off Section Page #
OFF I_______I 1-4 For Future Use
OFF I_______I 5 6-Digit User Access Codes 4-Digit User Access Codes 5.1 15
OFF I_______I 6 Busy tone detection enabled Busy tone detection disabled 5.5 17
OFF I_______I 7-8 For Future Use
Module Programming*
[801] PC5400 Printer Module Programming
Please refer to your PC5400 Installation Manual for installation and programming instructions.
[803] Alternative Communicator Programming
Please refer to your LINKS2X50, Skyroute Installation Manual for installation and programming instructions.
[804] PC5132 Wireless Expansion Programming
Please refer to your PC5132 Installation Manual for programming locations and instructions.
* LINKS2X50 and Skyroute modules have not been investigated by UL.
40
P r o g r a m m i n g W o r k s h e e t s
[996] Restore PC5132 to Factory Default Programming (Section 5.28 “Resetting Factory Defaults*” on page 26)
[997] Restore PC5400 to Factory Default Programming (Section 5.28 “Resetting Factory Defaults*” on page 26)
[999] Restore PC580 to Factory Default Programming (Section 5.28 “Resetting Factory Defaults*” on page 26)
41