Load Computation: General Notes

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

GENERAL NOTES:

LOAD COMPUTATION
1.0 ALL WORK HEREIN SHALL COMPLY WITH THE LATEST
PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE
AND NATIONAL ELECTRIC CODES WITH THE RULES AND
REGULATIONS OF THE NATIONAL AND LOCAL AUTHORITIES
CONCERNED IN THE ENFORCEMENT OF ELECTRICAL LAWS
AND ORDINANCES AND WITH RULES AND REGULATIONS OF
THE POWER COMPANY CONCERNED.
2.0 ALL WORKS HEREIN SHALL BE DONE UNDER THE DIRECT
SUPERVISION OF THE DULY QUALIFIED AND COMPETENT
LICENSED ELECTRICAL ENGINEER.
3.0 ALL MATERIALS TO BE USED SHALL BE NEW & INSTALLED IN
APPLICATION TO WHICH THEY ARE INTENDED
4.0 THE MINIMUN SIZE OF WIRES AND CONDUIT SHALL BE 3.5
SQ.MM. IN TYPE THHN COPPER AND 15 MM Ø
TOTAL RESPECTIVELY (REFER TO LOAD SCHEDULE FOR OTHER
WIRE SIZES AND TYPE OF INSULATION)
ɸ 5.0 ALL MOUNTING HEIGHTS ARE SUBJECT TO
PME'S/ELECTRICAL ENGINEER APPROVAL PRIOR TO THE
I N S T A L L A T I O N .
6.0 THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES
AT SITE AND COORDINATE THE WORKS WITH THE SEWER
LINE EFFLUENT DISPOSAL POINT AND WATER SERVICES
C O N N E C T I O N P O I N T .
7.0 ALL SPARE SHALL BE PROVIDED WITH EMPTY RIGID PVC
PIPE, 13 mm Ø & SHALL EXTEND 0.30 m ABOVE CEILING
EXISTING TAPPING POINT 8.0 THE TYPE OF POWER SERVICE TO BE SUPPLIED SHALL BE
240VOLTS,3 PHASE
S I N G L E P H A S E , 2 2 0 V , 6 0 H z , A C .
9.0 MAIN PANEL BOARD SHALL BE 30AT, 220V, 50AF, 1ɸ, 60 HZ,
BOLT-ON TYPE OF APPROVED BRAND, NEMA 1 ENCLOSURE
W I T H G R O U N D B U S B A R .

M KW METER

2- #14.0mm SQ THHN
LEGEND:
- 20W PINLIGHT
- CONVENIENT OULET

- WEATHER PROOF OUTLET


MAIN 1 60AT 2P 15AT 2P 2 L.O. - ONE-GANG SWITCH

C.O. 3 20AT 2P 20AT 2P 4 C.O. - TWO-GANG SWITCH


- THREE-GANG SWITCH
SPACE 3 20AT 2P 4 SPACE
M - KILOWATT METER

- SERVICE ENTRANCE
EGB
240VOLTS,SINGLE PHASE

MAIN PANEL BOARD CKT 2


MAIN - CIRCUIT HOMERUN

SINGLE LINE DIAGRAM - MAIN PANEL BOARD

PROFESSIONAL ELECTRICAL ENGINEER APPROVED & CONFORMED PROJECT TITLE: SHEET CONTENT SHEET NO.

ONE STOREY RESIDENTIAL BUILDING POWER & LIGHTING LAYOUT


SINGLE LINE DIAGRAM

REG. NO:
PROFESSIONAL ELECTRICAL ENGINEER

PTR NO:
MR. & MRS. ALVARO VALENCIA
WITH ROOF DECK
BRGY. CALANTIPAYAN, LOPEZ, QUEZON
LOAD COMPUTATION
ELECTRICAL NOTES
E-2
TIN: DATE ISSUED: PLACE: LOPEZ, QUEZON