Running Head: Technical Report For Equipment
Running Head: Technical Report For Equipment
Name
Institution
TECHNICAL REPORT FOR EQUIPMENT
2
Technical Report for Equipment
Introduction
Recently, there has been a rise of demand of technology advancement in the field of
medicine to improve on disease diagnosis and treatment. However, this has been a challenge
because the involved equipments are expensive in terms of purchase, power consumption,
maintenance and servicing the medical equipments. This report focuses on the medical
instrument used in conjunction with the related softwares for efficiency and proper application.
Therefore, the report entails an x-ray medical device, its principles, functions, environmental
impacts and its applications. Medical equipment is acquired or obtained for the purpose of
disease investigation, deterrence, monitoring, treatment and eventually eradication from the
human body.
X-ray Equipment
X-ray apparatus is a medical imaging instrument applied in the health sector and it is of
diverse models. Some models tend to consume low power voltage while others consume high
voltage power. This equipment is majorly used for a whole patient cycle for examination,
treatment and monitoring the patient with the help of a radiographer or medical practitioner. It
radiates rays towards the patient’s body especially the affected parts like fractures for diagnosis
of a defect (for example bone fracture). There exist several models of which some are manual
while others are automated. Figure 1 shows a pictorial representation of the X-ray machine
Figuren1: High voltage and x-ray tube filament circuit, and physical automated appearance
Equipment acquisition
Purchase of an x-ray machine should take into consideration of the procurement that is
sustainable to the public. This reason calls for consideration of the following factors while
durability of the equipment as well as the reliability in diagnosis. These factors should be taken
into account because the apparatus involves direct service delivery to the public thus their
consideration is real essential. It then means that the procurement process should be a green
public procurement (GPP). GPP is acquisition of a service or equipment which has minimal
environmental effect in its existence with respect to public demand. The implication here is that
the X-ray model should consume reasonable power and maintenance cost, should be common
Equipment Installation
Once the X-ray instrument has been acquired, then installation commences immediately
of course with stipulated standard instructions. For instance in the case of this model (AAA84-
115298), the x-ray head is put on the ground by a pulley and gradient as the trailer leaves. Water
TECHNICAL REPORT FOR EQUIPMENT
4
tubes and electrical cables joining the X-ray head to other parts of the equipment are unwinding
automatically while put on the ground as the trailer is leaving. Usually the allowed standard
distance between the trailer and the head of the x-ray should be 300 feet. When trailer setting is
completed, the control console is installed 150 feet away from the trailer as the control cable
joining the control panel to the trailer is winding down from its towline drum.
Figure 2: A fully x-ray machine set up and its medical application in scanning
X-ray equipment shown in figure 2 makes an electrical or physical contact with the patient body
The instrument comprises of the cathode and the anode. Once the power supply is
initiated through the x-ray tube, electrons starts flowing from the cathode to the anode. As the
electrons are in motion they tend to lose energy and eventually generate an x-ray beam
(radiation). In general;
E = hʋ (1)
5
When an electron moves from point 1 to point 2 then the energy involved becomes;
E0 – E1 (2)
The x-rays produced are characteristic of the sample under study or diagnosis.
X-ray as medical equipment is necessary in our hospitals. This implies that the costs
related to its operation must be reasonable to hospitals and the public. It consumes higher energy
voltage during intensive examination or imaging as a result high costs are required to meet the
daily operation. This brings to attention that any engineer should use his/her skills well for
Environmental aspects of the x-ray machine are important because it identifies the
benefits and hazards that may brought about by use of the equipment. The x-ray is good, safe and
However, if the equipment is mishandled, it can cause a menace to both the user and others.
Beryllium is used in the tubing system and is believed to be toxic chemical to organic tissues
thus qualifying to be a cancer causing agent (carcinogenic). The materials used in the x-ray are
mostly recyclable and hence they can be reused (about 95% material can be reused as well as
TECHNICAL REPORT FOR EQUIPMENT
6
3.9% energy value). This calls for an aware, knowledgeable man power for effective usage of the
equipment. However, medical engineers are still on a run to find a better replacement of this
element and its compounds to curb the negative effect that is associated.
Conclusions
necessary for fast and better imaging and diagnosis. This is because x-ray only requires proper
maintenance and few chemicals (only beryllium). Environmental assessment and economic
Recommendations
Government and other stakeholders should step forward in support of every hospital to
acquire x-ray equipment with expertise. Installation of the x-ray medical equipment should be
7
Reference list
Martz, H. E., Logan, C. M., Schneberk, D. J., & Shull, P. J. (2016). X-ray Imaging:
Shealy, A. (2019). U.S. Patent No. 10,172,576. Washington, DC: U.S. Patent and Trademark
Office.
Whitaker, J. C., & Mancini, R. K. (2018). Technical documentation and process. CRC Press.