Stud Calculations C16 B3 Level
Stud Calculations C16 B3 Level
Stud Calculations C16 B3 Level
Calculation for shear transfer through bond stress and shear studs
Length of Composite column = 1200
Breadth of Composite column = 900 mm
Top Flange Width (B) = 600 mm
Top Flange Thickneess (tf) = 50 mm
Web Depth (h) = 600 mm
Web Thickness (tw) = 30 mm
Bottom Flange Width (B) = 600 mm
Bottom Flange Thickneess (tf) = 50 mm
Height of the column H = 3400 mm
Modulus of elasticity of steel E = 210000 N/mm2
Yield stress Fy = 450 N/mm2
Charactristic concrete strength Fc = 60 N/mm2
Elasticity of concrete Ec = 4700*sqrt(Fc') Ec = 32562.56
Introduction length Lint = 1800 mm
Shear stud dia hd = 19 mm
Ultimate stress of studs Fu = 450.00 N/mm2
No. of shear studs per section n = 6 No.
Spacing of studs along member length s = 300 mm
Bond stress Tbd = 0.3 N/mm2 Eurocode 4
Rebar Dia = 25
Rebar No = 24
Total Axial Load transfered at floor level = 2182 C7 at 3rd