United Proarc Corporation: Engineering Department Technique Directive
United Proarc Corporation: Engineering Department Technique Directive
United Proarc Corporation: Engineering Department Technique Directive
Subject: MASTER Series Regular Maintenance Doc No: RD-0606-01 Rev.: 1.0
Issue Date: 2004/06/05 Page 12 of 15
ȜMechanismȝ
ǺPlease follow the check-points and carry out regular maintenance.
Subject: MASTER Series Regular Maintenance Doc No: RD-0606-01 Rev.: 1.0
Issue Date: 2004/06/05 Page 13 of 15
ȜN1ȝǺIt’s strictly forbidden to apply high-viscosity grease on the rack and pinion, due to the
high-viscosity grease will cause the dust / particle of material stick together with grease and this
will cause abnormal wearing of rack / pinion. For maintenance of the rack and pinion, clean the
surface and apply anti-rust grease (Lubrication grease SD40 or #32 is recommended). Use an oil
cloth with SD40 / or #32 oil and apply on the rack / pinion for anti-rust purpose.
ȜN2ȝǺRenew the lubrication oil of the precision worn reducer yearly. The lubrication-oil designated no. is
Tivela WB (per unit 0.3 Lit) and the renewing job is carried out by ProArc’s customer service
department or its agent / domestic distributor.
ȜN3ȝǺSelf-lubrication felt will be worn out due to dust / particle after 6 months running, please renew
the felt according to the check-points list to prevent other components be damaged abnormally.
ȜN4ȝ
ǺAccording to the DIN/JIS stipulation, as a routine job, it is advisable to re-correct the level / parallel
/ linearity of rail every year.
Please re-correct the level / parallel / linearity of the rail every year and follow the DIN8523
regulations to ensure the equipment would maintain its precision condition.
The re-correction job will be carried out by ProArc’s customer service department or its agent /
domestic distributor.
ȜN5ȝ
ǺLeakage test - the leakage test is a safety test for the cutting gas piping, connector …etc. After test,
user could make estimation for changing the piping, connector, regulator….etc. for safety reason.
The Leakage-test will be carried out by ProArc’s customer service department its agent / domestic
distributor.
United Proarc Corporation Engineering System
Subject: MASTER Series Regular Maintenance Doc No: RD-0606-01 Rev.: 1.0
Issue Date: 2004/06/05 Page 15 of 15