0% found this document useful (0 votes)
39 views12 pages

Quantity List and Pricing Table of Partitioned & Subdivisional Projects and Unit Rate Preliminaries

1. The document provides a quantity list and pricing table for architectural works on an academic building project. It includes items like mechanical connections, inaccessible roofing, and planting roof layers. 2. The list includes over 50 line items with descriptions of materials, thicknesses, and installation methods. Unit prices and totals are provided but tax and VAT are not included. 3. Rates will remain the same for the first floor but increase by 3% for each additional floor lifted for the project. The document was prepared by Archaic Architects Ltd. based in Dhaka, Bangladesh for a maritime university project.

Uploaded by

Tanvir Islam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views12 pages

Quantity List and Pricing Table of Partitioned & Subdivisional Projects and Unit Rate Preliminaries

1. The document provides a quantity list and pricing table for architectural works on an academic building project. It includes items like mechanical connections, inaccessible roofing, and planting roof layers. 2. The list includes over 50 line items with descriptions of materials, thicknesses, and installation methods. Unit prices and totals are provided but tax and VAT are not included. 3. Rates will remain the same for the first floor but increase by 3% for each additional floor lifted for the project. The document was prepared by Archaic Architects Ltd. based in Dhaka, Bangladesh for a maritime university project.

Uploaded by

Tanvir Islam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 12

Quantity list and pricing ta

Project Name: Academic Building-Architectural Works

Name of
No.
Project

Mechanical
51
connection

Mechanical
52
connection

Mechanical
53
connection

Inaccessible
61 roof (for the
roof of
elevator and
plant room)
Eaves-(Refer
to the
62 inaccessible
roofing
practice)
Planting roof
(two
63 waterproof
layers,
waterproof
level: class 1)
Quantity list and pricing table of partitioned & subdivisional proje

demic Building-Architectural Works

Project feature description

1. Connection method: straight threaded joint within φ25

1. Connection method: cold-pressed sleeve joint within φ25

1. Connection method: cold-pressed sleeve joint φ25 or more


1. Protective course: 50 thick C25 fine stone concrete protective course (with φ6 grade I steel two way@150
reinforced wire mesh fixed by binding or spot welding, with dividing joint), @4000 expansion joint, bottom 20 and
surface 25, steel frame disconnected, caulked with silicone sealing paste.

2. Dry-laid polyester fiber non-woven fabric (200g/m^U2^U) with a lap width of not less than 150

3. 65 thick foam glass insulation board (combustion performance: class A).

4. 30 thick 1:3 cement mortar leveling course (including composite anti-crack fiber)

5. 1:8 weight ratio cement hydrophobic expanded perlite slope course 3% with the thinnest part of 30 thick, sloping
to the drain according to the drawings.

6. 2.5 thick self-adhesive polymer waterproof membrane

7. 3 thick synthetic polymer waterproof coating, turn up along the wall in the case of buildings with 300 height
calculated from the highest point of the roof finished faceed face, and use 150 high galvanized steel plate to
compact and seal at the junction along the wall.

8. 20 thick 1:2.5 cement mortar leveling course

9. Take reinforcing concrete structural slab as base course, coated with base course treatment agent.
1. Protective course: 50 thick C25 fine stone concrete protective course (with φ6 grade I steel two way@150
reinforced wire mesh fixed by binding or spot welding, with dividing joint), @4000 expansion joint, bottom 20 and
surface 25, steel frame disconnected, caulked with silicone sealing paste.

2. Dry-laid polyester fiber non-woven fabric (200g/m^U2^U) with a lap width of not less than 150

3. 65 thick foam glass insulation board (combustion performance: class A). (calculated separately)

4. 30 thick 1:3 cement mortar leveling course (including composite anti-crack fiber)

5. 1:8 weight ratio cement hydrophobic expanded perlite slope course 3% with the thinnest part of 30 thick, sloping
to the drain according to the drawings.

6. 2.5 thick self-adhesive polymer waterproof membrane (calculated separately)

7. 3 thick synthetic polymer waterproof coating, turn up along the wall in the case of buildings with 300 height
calculated from the highest point of the roof finished faceed face, and use 150 high galvanized steel plate to
compact and seal at the junction along the wall (calculated separately)

8. 30 thick 1:3 cement mortar leveling course

9. Take reinforcing concrete structural slab as base course, coated with base course treatment agent.
1、300厚种植土
1. 300 thick planting soil
2、过滤布
2. Filter fabric

3. 20 high drainage tabs with convex side facing up

4. 50 thick C25 fine stone concrete protective course (with φ6 grade I steel two way@150 reinforced wire mesh
fixed by binding or spot welding, with dividing joint), @4000 expansion joint,bottom20 and surface 25, steel frame
disconnected, caulked with silicone sealing paste.

3. 1.5 thick synthetic polymer root puncture resistant self-adhesive waterproof membrane, turn up 300 along the
wall in case of building. (calculated separately)

5. 10 thick low strength grade mortar (M7.5) isolation layer.

6. Dry-laid polyester fiber non-woven fabric (200g/m^U2^U) with a lap width of not less than 150

7. 65 thick foam glass insulation board (combustion performance: class A).

8. 30 thick 1:3 cement mortar leveling course (including composite anti-crack fiber)

9. 1:8 weight ratio cement hydrophobic expanded perlite slope course 3% with the thinnest part of 30 thick, sloping
to the drain according to the drawings.

10. 2.5 thick self-adhesive polymer waterproof membrane, turn up along the wall in the case of buildings with 300
height calculated from the highest point of the roof finished face, and use 150 high galvanized steel plate to
compact and seal at the junction along the wall (calculated separately)

11. 3 thick synthetic polymer waterproof coating, turn up along the wall in the case of buildings with 300 height
calculated from the highest point of the roof finished faceed face, and use 150 high galvanized steel plate to
compact and seal at the junction along the wall (calculated separately)

12. 20 thick 1:2.5 cement mortar leveling course

13. Take reinforcing concrete structural slab as base course, coated with base course treatment agent.
** TAX & VAT are not included with the rate mentioned above **
** These rate will be same up to 1st floor and 3% rate will be increased for every one floor lifting **

Archaic Architects Ltd.


House #375, Road # 28
Mohakhali DOHS, Dhaka
Email:
Phone:
ivisional projects and unit rate preliminaries

Tender section: Bangladesh


Maritime University project

Amount (yuan)
Unit of
Engineerin
measure
g quantity Among them:
ment Comprehensive unit Comprehensive
provisional
price total price
valuation

个 2768 -
Piece

个 904 -
Piece

个 393 -
Piece
m2 209.83 -
m2 183.63 -
m2 2210.11 -

-
\08
Table 08

You might also like