Point Cloud: User's Guide
Point Cloud: User's Guide
User's Guide
June 2014
DSP3D-PE-200086F
Copyright
Copyright © 2008-2014 Intergraph® Corporation. All Rights Reserved. Intergraph is part of Hexagon.
Including software, file formats, and audiovisual displays; may be used pursuant to applicable software license agreement; contains
confidential and proprietary information of Intergraph and/or third parties which is protected by copyright law, trade secret law, and
international treaty, and may not be provided or otherwise made available without proper authorization from Intergraph Corporation.
Portions of this software are owned by Spatial Corp. © 1986-2014. All Rights Reserved.
Portions of the user interface copyright 2012-2014 Telerik AD.
Documentation
Documentation shall mean, whether in electronic or printed form, User's Guides, Installation Guides, Reference Guides,
Administrator's Guides, Customization Guides, Programmer's Guides, Configuration Guides and Help Guides delivered with a
particular software product.
Other Documentation
Other Documentation shall mean, whether in electronic or printed form and delivered with software or on Intergraph Smart Support,
SharePoint, or box.net, any documentation related to work processes, workflows, and best practices that is provided by Intergraph
as guidance for using a software product.
Terms of Use
a. Use of a software product and Documentation is subject to the End User License Agreement ("EULA") delivered with the
software product unless the Licensee has a valid signed license for this software product with Intergraph Corporation. If the
Licensee has a valid signed license for this software product with Intergraph Corporation, the valid signed license shall take
precedence and govern the use of this software product and Documentation. Subject to the terms contained within the
applicable license agreement, Intergraph Corporation gives Licensee permission to print a reasonable number of copies of the
Documentation as defined in the applicable license agreement and delivered with the software product for Licensee's internal,
non-commercial use. The Documentation may not be printed for resale or redistribution.
b. For use of Documentation or Other Documentation where end user does not receive a EULA or does not have a valid license
agreement with Intergraph, Intergraph grants the Licensee a non-exclusive license to use the Documentation or Other
Documentation for Licensee’s internal non-commercial use. Intergraph Corporation gives Licensee permission to print a
reasonable number of copies of Other Documentation for Licensee’s internal, non-commercial. The Other Documentation may
not be printed for resale or redistribution. This license contained in this subsection b) may be terminated at any time and for any
reason by Intergraph Corporation by giving written notice to Licensee.
Disclaimer of Warranties
Except for any express warranties as may be stated in the EULA or separate license or separate terms and conditions, Intergraph
Corporation disclaims any and all express or implied warranties including, but not limited to the implied warranties of merchantability
and fitness for a particular purpose and nothing stated in, or implied by, this document or its contents shall be considered or deemed
a modification or amendment of such disclaimer. Intergraph believes the information in this publication is accurate as of its
publication date.
The information and the software discussed in this document are subject to change without notice and are subject to applicable
technical product descriptions. Intergraph Corporation is not responsible for any error that may appear in this document.
The software, Documentation and Other Documentation discussed in this document are furnished under a license and may be used
or copied only in accordance with the terms of this license. THE USER OF THE SOFTWARE IS EXPECTED TO MAKE THE FINAL
EVALUATION AS TO THE USEFULNESS OF THE SOFTWARE IN HIS OWN ENVIRONMENT.
Limitation of Damages
IN NO EVENT WILL INTERGRAPH CORPORATION BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL INCIDENTAL,
SPECIAL, OR PUNITIVE DAMAGES, INCLUDING BUT NOT LIMITED TO, LOSS OF USE OR PRODUCTION, LOSS OF
REVENUE OR PROFIT, LOSS OF DATA, OR CLAIMS OF THIRD PARTIES, EVEN IF INTERGRAPH CORPORATION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
UNDER NO CIRCUMSTANCES SHALL INTERGRAPH CORPORATION’S LIABILITY EXCEED THE AMOUNT THAT
INTERGRAPH CORPORATION HAS BEEN PAID BY LICENSEE UNDER THIS AGREEMENT AT THE TIME THE CLAIM IS
MADE. EXCEPT WHERE PROHIBITED BY APPLICABLE LAW, NO CLAIM, REGARDLESS OF FORM, ARISING OUT OF OR IN
CONNECTION WITH THE SUBJECT MATTER OF THIS DOCUMENT MAY BE BROUGHT BY LICENSEE MORE THAN TWO (2)
YEARS AFTER THE EVENT GIVING RISE TO THE CAUSE OF ACTION HAS OCCURRED.
IF UNDER THE LAW RULED APPLICABLE ANY PART OF THIS SECTION IS INVALID, THEN INTERGRAPH LIMITS ITS
LIABILITY TO THE MAXIMUM EXTENT ALLOWED BY SAID LAW.
Export Controls
Intergraph Corporation’s software products and any third-party Software Products obtained from Intergraph Corporation, its
subsidiaries, or distributors (including any Documentation, Other Documentation or technical data related to these products) are
subject to the export control laws and regulations of the United States. Diversion contrary to U.S. law is prohibited. These Software
Products, and the direct product thereof, must not be exported or re-exported, directly or indirectly (including via remote access)
under the following circumstances:
a. To Cuba, Iran, North Korea, Sudan, or Syria, or any national of these countries.
b. To any person or entity listed on any U.S. government denial list, including but not limited to, the U.S. Department of Commerce
Denied Persons, Entities, and Unverified Lists, http://www.bis.doc.gov/complianceandenforcement/liststocheck.htm, the U.S.
Department of Treasury Specially Designated Nationals List, http://www.treas.gov/offices/enforcement/ofac/, and the U.S.
Department of State Debarred List, http://www.pmddtc.state.gov/compliance/debar.html.
c. To any entity when Licensee knows, or has reason to know, the end use of the Software Product is related to the design,
development, production, or use of missiles, chemical, biological, or nuclear weapons, or other un-safeguarded or sensitive
nuclear uses.
d. To any entity when Licensee knows, or has reason to know, that an illegal reshipment will take place.
Any questions regarding export or re-export of these Software Products should be addressed to Intergraph Corporation’s Export
Compliance Department, Huntsville, Alabama 35894, USA.
Trademarks
Intergraph, the Intergraph logo, PDS, SmartPlant, FrameWorks, I-Sketch, SmartMarine, IntelliShip, ISOGEN, SmartSketch,
SPOOLGEN, SupportManager, SupportModeler, Sapphire, and Intergraph Smart are trademarks or registered trademarks of
Intergraph Corporation or its subsidiaries in the United States and other countries. Microsoft and Windows are registered trademarks
of Microsoft Corporation. ACIS is a registered trademark of SPATIAL TECHNOLOGY, INC. Infragistics, Presentation Layer
Framework, ActiveTreeView Ctrl, ProtoViewCtl, ActiveThreed Ctrl, ActiveListBar Ctrl, ActiveSplitter, ActiveToolbars
Ctrl, ActiveToolbars Plus Ctrl, and ProtoView are trademarks of Infragistics, Inc. Incorporates portions of 2D DCM, 3D DCM, and
HLM by Siemens Product Lifecycle Management Software III (GB) Ltd. All rights reserved. Gigasoft is a registered trademark, and
ProEssentials a trademark of Gigasoft, Inc. VideoSoft and VXFlexGrid are either registered trademarks or trademarks of
ComponentOne LLC 1991-2013, All rights reserved. Oracle, JD Edwards, PeopleSoft, and Retek are registered trademarks of
Oracle Corporation and/or its affiliates. Tribon is a trademark of AVEVA Group plc. Alma and act/cut are trademarks of the Alma
company. Other brands and product names are trademarks of their respective owners.
Point Clouds......................................................................................................................................... 11
Index ..................................................................................................................................................... 29
Documentation Set
Intergraph SmartTM 3DDocumentation is available as Adobe PDF files. The content is the same
as the online Help. To access these PDF documents, click Help > Printable Guides in the
software.
The documentation set is divided into four categories:
Administrative guides contain information about installing, configuring, customizing, and
troubleshooting.
User's guides provide command reference and how-to information for working in each task.
Reference data guides define the reference data workbooks. Not all tasks have reference
data.
ISOGEN guides.
Administrative Guides
Intergraph SmartTM 3D Installation Guide - Provides instructions on installing and configuring the
software.
Project Management User's Guide - Provides instructions for setting up the databases, creating
permission groups, backing up and restoring project data, assigning access permissions to the
model, defining and managing locations for Global Workshare, and version upgrade.
Global Workshare Guide - Provides instructions for setting up the software and the databases to
work in a workshare environment.
Interference Checking Guide - Provides information on installing, configuring, and using the
interference detection service.
Integration Reference Guide - Provides information about installing, configuring, and using
Smart 3D in an integrated environment.
Interpreting Human Piping Specifications - Provides information about how to interpret human
piping specifications so that you can create the corresponding piping specification in the
software.
Design and Data Exchange with PDMS - Provides information about how to export model data
from Smart 3D to PDMS and from PDMS to Smart 3D. Specific guidelines relating to best
practices and known limitations of the export functionality are also included.
Export to Plant Design System (PDS) User's Guide - Provides information about how to export
model data from Smart 3D to PDS. Specific guidelines relating to best practices and known
limitations of the export functionality are also included.
Point Cloud Reference - Provides information for referencing point cloud files provided by point
cloud vendors in Smart 3D.
Troubleshooting Reference Guide - Provides information on how to resolve errors that you might
encounter in the software by documenting troubleshooting tips, error messages, and To Do List
messages.
Plant Design System (PDS) Guide - Provides all information needed to use PDS with Smart 3D.
Topics include referencing active PDS projects in Smart 3D, exporting PDS data and importing
that data into Smart 3D, and converting PDS reference data to Smart 3D reference data.
Intergraph SmartTM 3D Programmer's Guide - Provides information about custom commands,
naming rules, and symbol programming. If you install the Programming Resources, this
document is delivered to the [Product Folder]\Programming\Help folder.
User's Guides
Catalog User's Guide - Provides information about viewing, editing, and creating reference data
and select lists (codelists).
Civil User's Guide - Provides information about routing trench runs in the model.
Common User's Guide - Provides information about defining workspaces, manipulating views,
and running reports.
Compartmentation User's Guide - Provides instruction for placing volume objects such as
compartments and zones in the model.
Electrical User's Guide - Provides information about routing electrical cable, cableway, cable
tray, and conduit.
Equipment and Furnishings User's Guide - Provides information about placing equipment.
Geometry Analysis and Repair User's Guide - Provides instructions for importing and exporting
model data, checking the data against a defined set of requirements, and repairing the data.
Grids User's Guide - Provides instructions for creating coordinate systems, elevation grid
planes, vertical grid planes, radial cylinders, radial planes, grid arcs, and grid lines.
Hangers and Supports User's Guide - Provides instructions on placing piping, duct, and
cableway supports in the model.
Hole Management User's Guide - Provides instructions for placing, reviewing, and approving
holes in a structure.
HVAC User's Guide - Provides instructions for routing HVAC duct.
Molded Forms User's Guide - Provides instructions for placing hull, bulkheads, major openings,
stiffeners, and other major structural components in the model.
Orthographic Drawings User's Guide - Provides information about creating and managing
orthographic drawings.
Piping Isometric Drawings User's Guide - Provides information about creating and managing
piping isometric drawings.
Piping User's Guide - Provides instructions for routing pipe and placing valves, taps, and pipe
joints.
Planning User's Guide - Provides instructions about defining the assembly hierarchy (production
bill of material) by creating blocks and assemblies and by specifying the assembly sequence.
Reports User's Guide - Provides information about creating and managing spreadsheet reports.
Space Management User's Guide - Provides instructions for placing space objects such as
areas, zones, interference volumes, and drawing volumes in the model.
Structural Analysis User's Guide - Provides instructions for defining loads, load cases, load
combinations, and the importing and exporting of analytical data.
Structural Detailing User's Guide - Provides instructions for creating, detailing, and maintaining
the structural members of a model.
Structural Manufacturing User's Guide - Provides instructions for creating and maintaining
manufacturing objects such as templates, jigs, and margins.
Structure User's Guide - Provides instructions for placing structural members, such as beams,
columns, slabs, openings, stairs, ladders, equipment foundations, and handrails.
Systems and Specifications User's Guide - Provides instructions for creating systems and
selecting the available specifications for each system type.
HVAC 3D Symbols Reference - Provides information about the HVAC 3D symbols that are
available.
Reference Data Guide - Provides instructions about the Bulkload utility, codelists, and the
reference data common to several disciplines.
Piping Reference Data Guide - Provides information about piping reference data including piping
specifications, piping specification rules, piping parts, and piping symbols.
Piping 3D Symbols Reference - Provides information about the piping 3D symbols that are
available.
Space Management Reference Data Guide - Provides information about space management
reference data.
Structure Reference Data Guide - Provides information about structural reference data.
Structure 3D Symbols Reference - Provides information about the stair, ladder, footings, and
equipment foundation 3D symbols that are available.
Structural Reference Data Overview - Provides an overview of the marine mode structural
reference data library.
ISOGEN Guides
Symbol Keys Reference Guide - Provides information about the symbol keys for isometric
drawings. This guide is from Alias, the makers of ISOGEN.
Documentation Comments
We welcome comments or suggestions about this documentation. You can send us an email at:
[email protected].
Documentation updates for supported software versions are available from
https://smartsupport.intergraph.com (https://smartsupport.intergraph.com).
Measuring
You can measure point-to-point within the cloud and cloud point-to-3D object. Select Tools >
Measure, or click on the toolbar.
Create Filters
If the third-party point cloud vendor software has been installed and registered, you can select
point clouds using the Filter Properties dialog box. From the System or Object Type tab, you
can select the point cloud only or the point cloud system.
When measuring a distance, you must click two selection points to define the distance to be
measured. Measuring should only be done in Orthographic mode, not Perspective.
Simple measurements are on the toolbar. Click Tools > Measure to open other
measurement modes.
The distances display in the Text view.
Checking Interferences
Interference checking (IFC) ensures that parts do not occupy the same volumetric space and
that each part meets the design criteria for clearance. A successful interference check ensures
that there is sufficient space around the parts so that they can operate properly, be serviced
properly, and be easily installed or removed when necessary. The IFC process can look at all
model data, including data from a referenced 3D model, a referenced PDS project (32-bit only),
referenced MicroStation and 3D AutoCAD files, and Point Clouds from third-party software with
valid connections.
There are two methods for interference checking:
Server-based interference checking called Database Detect. For more information, see
Server-Based Interference Checking (Database Detect) (on page 21).
Interactive interference checking called Local Detect. For more information, see Interactive
Interference Checking (Local Detect) in the Interference Checking Guide, available from the
Help > Printable Guides command in the software.
The major differences between the two methods are:
Runs continuously (System Administrator Works only within the current session
choice)
A dedicated server takes care of the IFC Provides immediate graphical feedback (works
Provides feedback on how much has been Checks only created and modified objects in a
checked in the entire plant model session
Interference markers associate and come Clears dynamic interferences after refreshing
into the workspace along with the object workspace
participating in the interference
Includes a referenced point cloud when the Receives the point cloud specification via the
Smart 3D Point Cloud Compare option is File > Define Workspace workflow in Smart
selected in the Project Management 3D when the Smart 3D Point Cloud Compare
interference checking settings. option is selected.
The Database interference checking objects, or markers, appear in the model until other objects
are moved so the interferences no longer exist, or the aspects for the interference process are
changed. It is not possible to delete an interference object in the same way you can delete other
objects in the model. However, you can tailor the display to hide acceptable interferences.
The Local Detect process marks any interference it finds with a cube interference marker. For
example, the software finds an interference and places a cube interference marker where there
is an interference between a pipe and the floor.
For both processes, the color of the marker indicates the type of the interference: red for severe,
green for clearance, and yellow for optional. You can modify the default interference marker
colors with the Format > Surface Style Rules command. You can change the size of both the
Database Detect and Local Detect interference markers using the Marker size option on the
Interference Server Setting dialog box in Project Management task and the Interference
Checking Settings dialog box in the Common task, respectively.
You can clear the acceptable interferences from your workspace by changing the required
action on the Interference List Dialog Box, and then editing the display properties on the
Interference Checking Settings Dialog Box.
In general, the software checks the parts involved in interfering objects to find and report the
interferences. For example, if you have a pipe run that consists of a pipe, an elbow, and a pipe,
The IFC service does not consume a license when it starts. It consumes a license only while
processing the model.
IFC consumes a license for every five models.
IFC cannot process a new model if a new license is not available.
If IFC fails to consume or release a license, the software logs error messages in the error
log and in the Event Viewer Application log with the source name IfcNtSvc.
You cannot set a number for processing models in the registry.
Database detection options are set in the Project Management task. You can also start and stop
the interference detection service in the Project Management task.
Interference detection requires disk space for the file cache that temporarily stores the
interference data. Before starting the interference process, the interference server checks to see
if enough space exists in the TMP location for the file cache. The server also checks to see if
you have the proper permissions to write, read, and delete files in the TMP location. During the
process, if the space becomes too low, the software stops IFC, and then displays an error
message. These checks primarily apply to the server-based interference process. Although,
they can apply to the local checking process if extremely low or no disk space is available for the
temporary folder on the local computer.
Configure automatic disk defragmentation in order to free space for the file cache.
After you start the process, use the Status tab on the Interference Server Settings dialog box
to monitor the start time, progress of the interference checking, time when the last part was
The interference checking service does not consume a license when it starts. It consumes a
license only while processing the model. For more information, see Checking Interferences.
If clashes between the point cloud and the Smart 3D objects are selected to check for
interferences, then Smart 3D Interference Detection Service or Smart 3D Interference
Detection Service 64-bit should be started from the command prompt. From the command
prompt, navigate to install\Foul Check\Middle\bin, and then type IFCNtSvc.exe /Auto/0,
and press ENTER.
Errors that are encountered during startup of the Database Interference Detection service
are logged to the Event Viewer Application Log with the source name IfcNtSvc.
Do not run the 32-bit and 64-bit interference detection services simultaneously on a
computer. IFC must only run as a single instance for the entire model.
You can also click Add and search for users using the Select Users and Groups
dialog box. This is a common Windows dialog box. For information regarding the
options in this dialog box, see your Windows documentation.
The Smart 3D Interference Detection service does not consume a license when it starts. It
consumes a license only while processing the model. For more information, see
To start the server interference detection process, you must have at least Read access to all
objects in the model and Write access to the model itself. Access privileges are assigned for
each permission group in the Project Management task. During the IFC process, if the
software denies access to an object, the server process stops and a message appears.
To view the status of the database interference detection process, right-click the
Interference Server icon in the Project Management tree, and click Properties. On the
Interference Server Settings dialog box, click the Status tab.
When the database interference check process is running, only the Stop command is
available. When the process is not running, the Start command and all process property
gadgets are available. The Stop command is not available.
When the database interference check is running and you add any permission group without
Read permissions for the server, the server automatically receives Read permissions and
finds collisions with the placed objects in that permission group.
When you modify permission groups in Project Management, the host for the existing,
running task does not receive the changes. To update the information, you must exit and
restart the interference detection process.
This option only checks active model objects against foreign objects. The option does
not check for interferences between two foreign objects (PDS to 3D AutoCAD, for
example), except when the two foreign objects are referenced 3D models.
Direct PDS project references are not processed in 64-bit IFC. You can either use
Reference 3D for your PDS projects or run 32-bit IFC.
Smart 3D - Point Cloud - Considers an attached point cloud during interference checking.
The Point Cloud check box must be selected to consider Smart 3D objects and the point
cloud. The point cloud must have a valid connection to the model with no unresolved vendor
licensing issues for the Point Cloud check box to be available.
Include clearance rule - Specifies the clearance rule to add to the Required type of
interference check.
Assign results to permission group - Specifies the permission group to which all the detected
interferences are assigned. The list displays only those permission groups to which the server
containing the interference checking software has Write access.
Marker size - Specifies the size of the interference graphic marker. Choose a size that is clearly
readable, but one that does not interfere with the smaller details in the workspace view.
Start - Begins the process. This option is only available in the Project Management task.
Stop - Closes the process. This option is only available in the Project Management task.
D
Database Detect Tab (Interference Dialog
Box) • 34
Documentation Comments • 13
Documentation Set • 9
I
Install Database Interference Detection
Service • 29
Interference Checking • 23
M
Measure Point Cloud and 3D Data • 19
P
Point Clouds • 17
Preface • 7
Project Management • 21
R
Reference a Point Cloud • 21
Remove a Point Cloud Reference • 21
S
Server-Based Interference Checking
(Database Detect) • 27
Set IFC Permission Requirements • 31
Set IFC Permissions • 32
Start the Database Interference Detection
Service • 30