EZConfigScanning v4 - ReleaseNotes
EZConfigScanning v4 - ReleaseNotes
EZConfig-Scanning v4
Version: 4.5
Page 1 of 13
Release Notes – EZConfig-Scanning v4
Table of Contents
1 Overview 3
1.1 Supported Browser 3
1.2 Communication Interfaces Supported 3
1.3 Platform Supported 3
2 Overview of Release 4
2.1.1 Features 4
2.1.2 Compatibility 5
3 Pre-Requisites 6
4 Limitations 9
5 List of Known Issues and Workarounds 10
5.1 Known issues in current release: 10
5.2 Known Issues from previous releases: 10
Page 2 of 13
Release Notes – EZConfig-Scanning v4
1 Overview
Honeywell’s EZConfig for Scanning is a free software download from http://www.honeywellaidc.com/ that
facilitates fast and easy one-to-one barcode scanner configurations. EZConfig for scanning versions 4.1 and
onward have been updated to be browser-based and improved to provide both an intuitive interface and enhanced
efficiency.
Page 3 of 13
Release Notes – EZConfig-Scanning v4
2 Overview of Release
2.1.1 Features
EZConfig-Scanning v4 is a browser based Scanner configuration tool.
Main features of 4.5 release:
Scan Data Window, Serial Data Window - Keep a running list of commands in the 'create
programming bar code' and 'command center' entry boxes.
“Reset to device default” support from the application.
Dropped the support for EB (Toggle device in and out of auxiliary port mode and send characters
out aux port) , FF (End Format) rules in Data Formatting.
Enhanced data capturing and Maintaining common/single EdgeBroker service & installation for
Cloud and local versions of EZConfig.
Clear pending client transactions if any at HPA once client session gets terminated.
Usability improvements for “Configuration History”.
IE 11 Support
Main features of 4.4 release:
Prefix/Suffix redesign in alignment with data formatting.
Application upgrade notification.
Improved the data display in Serial, Scan Data Window for better readability.
Discovery performance when working with cordless devices associated with RF Scanners.
Main features of 4.3 release:
Data formatting redesign.
Auto firmware upgrade for RF Scanners.
Displaying license and plug-in as part of device discovery.
Auto-connect post flashing operation.
Usability improvements for “Configuration History” and “Compare & Clone” features.
Win 8 support.
IE10 support.
Main features of 4.2 release:
Port communication via “Serial Data Window”.
Capture image by providing menu commands from imaging tab.
Aztec/Data Matrix support for 2D bar code generation.
Image capture from selected RF Scanner.
Auto firmware upgrade.
Force Reader to Boot Mode support.
Main features of 4.1 release:
Improved HF [Page Navigation, Prefix/Suffix, Data Formatting etc].
Improved search in Disconnected Device mode by segregating the devices in to different
categories.
Progressive discovery and Auto connect to the first discovered device.
Interfaces supported: RS 232, USB serial, USB HID, USB HID KBD, USB HID Surepos.
Page 4 of 13
Release Notes – EZConfig-Scanning v4
2.1.2 Compatibility
Corded - 1400, 1900, 1911, 7580, 3310, 1200, 1250, 1300, N5600 engine, 8600 engine (MPX), 2700
(Stratos 2700), 1500, 1910i, N4300 (NGLE-HD), 7300, 4850 (MPX DR), 1280iFR-3 (Rifle)
Cordless - 1902, CCB, HAP, 1202, CCB00
Page 5 of 13
Release Notes – EZConfig-Scanning v4
3 Pre-Requisites
It is recommended to ensure that your browser has the below settings prior to work with the EZConfig-Scanning
v4 application.
1. Chrome Settings:
Always ensure to launch Chrome with the following settings. Ensure to close any other Chrome running
instances prior to apply it.
chrome.exe --allow-file-access-from-files --enable-file-cookies
ex: C:\Program Files\Google\Chrome\Application>chrome.exe --allow-file-access-from-files --enable-file-
cookies
2. Firefox Settings:
Page 6 of 13
Release Notes – EZConfig-Scanning v4
Page 7 of 13
Release Notes – EZConfig-Scanning v4
3. IE Settings
Enable the 'Use TLS 1.0' settings. Under Internet Options -> Advanced -> Security -> select "Use TLS
1.0"
Page 8 of 13
Release Notes – EZConfig-Scanning v4
4 Limitations
Virtual COM support – The current version of EZConfig only supports Virtual COM ports generated by the
HSM USB Serial Driver. Virtual COM ports generated by other drivers (i.e. ports that come up when using
RS232 to USB adaptor) are not supported during discovery operation. If you still need to use such ports,
Change the value of “SupportVirtualCOM” in the file “EZCSConfig.xml” under installation path to “1” from
the default value “0”, power cycle the device and refresh EZConfig application.
o If the discovery/configure device operation freezes in the middle, the suggested work around is to
clear the registry entries under the path
“HKEY_LOCAL_MACHINE\HARDWARE\DEVICEMAP\SERIALCOMM\”, power cycle the device
and refresh EZConfig application. If the problem (application hang) still persists, reset the
“SupportVirtualCOM” in the file “EZCSConfig.xml” under installation path to default value “0” and
refresh the application.
Image Capture supports JPEG, BMP formats for all browsers. TIFF format is supported only in IE. Rest all
formats are not supported.
In IE browser, users may notice alerts while running the application due to browser security settings. This
is expected behavior. Click Yes or “Allow ActiveX content” in the resulting alerts.
Force Reader to Boot Mode functionality is supported only for Xenon based devices in RS232 interface at
115200 baud rate and 8N1 data bits.
FRLE support - FRLE (7300) device defaults to PWRMOD2 that causes it to enter sleep mode quickly.
Due to this behavior, EZConfig users may encounter errors while performing operations in “Scan Data
Window” and “Serial Data Window”. The suggested work around is to set the PWRMOD setting to 0
(zero) prior using “Scan Data Window” and “Serial Data Window”.
Perform install and uninstall of EZConfig with Admin privileges.
For un-installation of EZConfig, It is recommended to do it from Start menu-> All Programs->Honeywell-
>EZConfig-Scanning v4-> Uninstall EZConfig-Scanning v4 with admin privileges.
If un-installing it from Control Panel->Add/Remove Programs, perform uninstall of “EZConfig-Agent”
followed by “EZConfig-Scanning”.
Page 9 of 13
Release Notes – EZConfig-Scanning v4
EZCS4-1297 Cancel operation not handled as part of EZConfig installation [Install/Repair/Un install].
1 Severity: Marginal
Workaround: Re launch the setup to perform the required operation. Ex: Instead of
cancelling during installation – Re launch setup and perform un installation.
EZCS4-1229 Keyboard layout is not rendered properly while creating/editing prefix/suffix in IE10
browser.
EZCS4-1221 Tooltip for the drop down items in configuration settings page is not displayed properly
in IE10 browser.
EZCS4-1144 Flash operation not working in IE9, when firmware file is located over network drive.
EZCS4-1140 License, plug-in information not seen consistently for 1900 and CCB/1902.
Page 10 of 13
Release Notes – EZConfig-Scanning v4
EZCS4-1129 Flash operation for Stratos 2700 device not working via auto firmware upgrade from IE
browser.
Observed data leakage when working with CCB/1902 connected in USB KBD interface.
EZCS4-1127
Frequency of occurrence: Frequent
6
Severity: Major
EZCS4-1042 Application crashing (Browser getting closed) when trying to use 'Print bar code
generation' on Chrome browser v29
Observed data leakage when working with Corded/CCB/1902 connected in USB KBD
EZCS4-1007 interface and REMIFC is set to 0
EZCS4-951 Image capture does not work for CCB with RF scanner in RS-232 interface configured
with lower baud rates (9600) and DPS Settings (Ex: 7O2).
Workaround: None.
EZCS4-947 Image capture operation is failing for 'cropped' Image type for cordless devices, if the
base image cropping parameters (IMGWNL, IMGWNR, IMGWNT and IMGWNB) are not
in sync with RF Scanner parameters.
Workaround: Change the image cropping parameters values in Sync with RF Scanner
before image capture operation.
Page 11 of 13
Release Notes – EZConfig-Scanning v4
EZCS4-894 In connected/disconnected mode when the response for the “Google Analytics” request
is delayed, UI rendering is getting delayed/not proper.
EZCS4-836 When working with cordless devices (CCB/HAP), color supported formats are shown on
UI, even when the associated RF scanner doesn't support color.
Workaround: None
EZCS4-823 Publisher name displayed as "Unknown" when trying to uninstall from control panel
Workaround: None
EZCS4-603 Disconnect notification not seen when connected to RS232 device and unplugged the
power supply/cable.
EZCS4-591 No barcode data seen in scan window for 7580 scanner with TRMUSB128 interface.
16 Severity: Minor
Workaround: Need to enable barcode scanning in the device using the command
"\X161\X0D1" for reading barcode data and disable using the command "X160\X0D1".
EZCS4-484 "Google Chrome is unresponsive. Re launch now?" message is seen, when trying to
launch the application post installation in the Finish Dialog.
Severity: Minor
Page 12 of 13
Release Notes – EZConfig-Scanning v4
EZCS4-427 Observed sometimes “EZConfig-Scanning v4” icon for the chrome instance.
Workaround: None
Page 13 of 13