My research and work over the past 30 years has always been at the cutting edge. As an operational
firefighter serving out of some of the world's busiest fire stations I have followed a quest to provide that vital
missing link between the excellent approaches being taken by members of the scientific fraternity, to
enhance firefighter safety with their complex calculations and lengthy technical papers. It wasn't always
easy! To transfer their message into 'firefighter speak' often took a great element of understanding and
appreciation of the practical aspects of their thesis.
On occasions I worked tentatively to advance my own theories, gained through my own experiences at fires in
London, New York and elsewhere, of things I had seen and done. I would sit and discuss these experiences
with scientists who were most keen to put a physical explanation to some situation, or occurrence, never
before documented through controlled laboratory research. In particular I worked to develop, since 1980, in
the areas of fire-ground operations that I felt particularly uncomfortable with as a firefighter with limited
knowledge. Was it correct to vent a roof or window, as I so often did in New York; or keep the fire under-
ventilated with an element of 'control', as I was taught to in London? Was it more effective to apply water in
direct flowing straight stream patterns as I was so used to doing in the South Bronx tenements in the mid
1970s, or were the emerging Swedish water-fog applications I utilized from 1984 onwards, in the west-end of
London, offering a safer approach? Did Positive Pressure Ventilation truly hold the key to smoke clearance?
Were there better ways to organize ourselves to fight fires on the upper floors of high-rise buildings? These
were all aspects of firefighting that struck me early on, needed a little 'tweaking'!
As my own concepts evolved I invented terminology where it did not exist, and redefined some terms that
had been misleadingly translated from Swedish into English, to describe methods and approaches that
firefighters might make to improve safety and effectiveness at fires. I presented over 100 technical papers
through the world's firefighting journals and as an international conference speaker, along with four books in
six languages, between 1979 to 2004 explaining these approaches and definitions. In some cases my views
were hotly disputed at the time by scientists and many operational fire officers who saw these approaches as
'new-wave' and against accepted 'tradition'. However, following the loss of several firefighter lives my initial
concepts, and associated terminology, of Tactical Ventilation; 3D Firefighting and Rapid Fire Development,
began to filter through in operational training texts and scientific research documents around the world. On
occasions, some of these terms would become shrouded and somewhat lost in definition and
misinterpretation.
In particular I would like to clarify some of these concepts, terms and definitions as they have evolved.
Fire Gas Ignition - It was the 1980s when I originally began to redefine some of the scientific
terminology and practical definitions that were in clear conflict with each other. The generic use of the term
'flashover' by firefighters to describe all instances of rapid fire development was a clear indicator that
firefighters, and in some situations scientists, were failing to grasp even a basic appreciation of the
differences between 'backdraft' and 'flashover'.
In the 1990s it further became obvious that although the reported theories of Rosander & Giselsson presented
scientific misinterpretations that caused some confusion when their Swedish terminology and definitions were
translated to English, their actual views that there were other related phenomena of rapid fire development
that firefighters urgently needed to become tactically aware of were correct.
In 1997 Bengtsson and Karlsson attempted to redefine the Swedish definitions to meet with international
concerns over the emergence of conflicting terminology. This resulted in the terms - övertändning
(flashover), backdraft (backdraft) and brandgasexplosion (translated as 'Smoke Gas Explosion' but later in
1999 as 'Fire Gas Explosion'). However, at the same time, in 1999, I published the term 'Fire Gas Ignition' in
six languages to amend Bengtsson and Karlsson's term and incomplete definition of 'brandgasexplosion'. This
became necessary, to group and describe a wide range of related scientific, and pseudo scientific, terms and
definitions that had emerged and were being used internationally in scientific research papers and by
firefighters worldwide. I had acknowledged and referred to previous documented and established scientific
definitions in doing so. My introduction and definition of this term was later (2002) debated with, and agreed
by, Dr Martin Thomas in the UK.
The fire gas explosion concept is not defined in any ISO standard. This concept is, however, used in many
countries and those definitions that exist are largely similar. One possible definition is given below:
"When fire gases leak into an area adjacent to a burning compartment they can become well mixed with the
air in that adjacent compartment. This mixture can fill all or part of the available volume and may be
within appropriate flammable limits. If the mixture is ignited this may cause a large increase in pressure.
This is called a fire gas explosion."
A fire gas explosion occurs without changing the status of any opening in the compartment. In order
for backdraft to occur the ventiation conditions in the compartment must change during the
development of the fire. Naturally, the boundary between the two concepts can at times be hazy.
The term brandgasexplosion (Fire Gas Explosion) and it's associated definition does not account for the fact
that 'smoke explosion' has existed for many years in the English language and has been used both practically
by firefighters in the UK and USA and documented by scientists from 1975 at least. It is difficult to find the
exact origin of the term, but is clear to see it is almost 100 years old and was originally used to describe an
ignition of combustion products under circumstances similar to backdraft. More recent scientific research has
defined this term. The most detailed paper by Sutherland (1999) clearly described the phenomenon of fire
gases igniting with 'explosive' force. However, this paper also described other events where smoke (fire gases)
may ignite without explosive force. There are references to earlier work by Croft (1980) and Wiekema (1984)
who inform that high-pressure waves associated with ignitions of the gases (in excess of 5 kPa) may be
termed ‘explosions’ and other such ignitions with minor pressure waves should be termed ‘flash-fires’. Then
there are auto-ignitions of the gases where they meet additional oxygen supplies at exit points etc. These
cannot be termed ‘explosions’ but are more suited to ‘ignitions’ as a description of the stated event.
It is essential to differentiate the various phenomena here so that firefighters are able to gain a wider
appreciation of slow rolling flame ignitions (more controllable) as opposed to the more dangerous and
explosive situations associated with smoke explosion (take fire gas explosion).
In my own term & definition fire gas ignition (1999) I have grouped the association with wide-ranging terms in
use in recognized firefighting training texts under this heading, conveniently ensuring all such terminology is
grouped under one of three headings as follows;
Fig.One - The three groups of Rapid Fire Development - Tactical Firefighting (CEMAC Belgium 2003) & 3D Firefighting (FPP/IFSTA USA 2005)
3D Firefighting - My introduction of the term (3D Firefighting) and its associated definitions were a
result of the confusing nature of the original Swedish translation of 'Offensive Firefighting'. Originally I used
this term for some years but in during the mid 1990s became uncomfortable with the conflict between the
use of this term and that of 'offensive firefighting' as used in the USA, and then increasingly in the UK, to
describe offensive and defensive modes of attack.
I was also (1993 onwards) introducing the concepts of pulsing and bursting water-fog patterns that I had
personally worked to develop operationally since 1984 to US firefighters. However, I was encountering much
opposition due to their insistence on confusing the tactic with that of indirect water-fog, which had caused
them some problems throughout the 1970s and 80s, almost to the point where they were opposed to any form
of fire attack utilizing water-fog patterns. I therefore redefined the term as 3D Firefighting (1999) and
introduced the teaching concept of a three-dimensional approach to applying water-fog (in m3 - into the
gaseous-phase combustion) as opposed to two dimensionally (as was normally the case in m2 - onto surface
fires etc). This new approach most certainly aided the firefighter's appreciation of not only gaseous-phase
firefighting concepts but also that of gaseous-phase combustion (ie; smoke burns)!
The definition of 3D Firefighting was therefore broadened to include not only pulsing and bursting nozzle
firefighting techniques but also concepts associated with gaseous-phase combustion in the form of flashover,
backdrafts and other fire gas ignitions. This teaching approach attempted to broaden a firefighter's tactical
vision and coping mechanisms beyond traditionally accepted parameters which in turn, enhanced their views
of other tactical practices, such as ventilation, PPV and CAFS when used in compartment fires. My original
concepts and terminology associated with 3D Firefighting have since found their way into NFPA (USA) training
texts, dedicated NRC Canada Research reports as well as ODPM and UK fire training documents.
However, there was an enigma attached to 3D Firefighting and pulsing water-fog patterns that evolved from
the training arena the Swedish firefighters had introduced. It was most easily conceived that the introduction
of gaseous-phase firefighting (3D Firefighting) was initially taught through the steel shipping containers that
were easily adapted for live fire training and economical and safe to run. However, firefighters became so
adept at dealing with the 1MW 30m3 fire load and at ceiling temperatures around 600degC believed they
were now able to utilize the gaseous-phase combustion with ease, sometimes with amazingly low flow-rates.
This set a worrying precedent that began to filter through onto the fire-ground! Firefighters were now coming
straight from the single 50m3 compartment training ground and tackling fires in larger fully involved
compartments but using the same nozzle pulsing tactics! In London (and other parts of the UK) it was
reported that firefighters were utilizing primary attack hose-lines against compartment fires with, in excess
of, 1000m2 of fire involvement and complaining the nozzle pulsing techniques would not work on 'real fires'!
I was quick to point out that such firefighting tactics when used offensively were reserved for the smaller
compartments, or situations up to 70m2 of fire involvement. Larger fires in larger enclosures demanded
straight stream direct fire attack at two dimensional surface burning. Whilst it was essential that we provided
our firefighters with the knowledge, training and equipment that would enable them to deal with three-
dimensional gaseous-phase combustion up to its limitation, it was equally important that we didn't deceive
ourselves into thinking this approach was the answer to every situation. In this respect, the recent ODPM
research into high-rise firefighting have failed to acknowledge the limitations of 3D compartment firefighting
tactics.
Tactical Ventilation - In 1984 I presented the first of a series of papers on venting practices by
firefighters in the Fire Journals. I had a conflict going on in my mind as to the varied approaches I had
experienced in the USA and the UK in terms of opening up or closing down of fire involved structures. My own
experience and intuition told me that there were achievable benefits but also disadvantages in both
approaches. In 1990 I introduced and defined my own concept of an internationally integrated approach
entitled Tactical Ventilation -
Structural ventilation or fire isolation tactics? - two options that both offer major benefits to the firefighter.
The choice in any situation is down to careful risk-assessment by balancing potential risks versus likely gains
and applying an 'objectives' test. In some situations an early venting action relies heavily on adequate
resources, equipment and manpower on-scene to ensure a safe and effective outcome. To be in a position to
operate effectively there must be a pre-plan that is documented by SOPs and firefighters must have early and
safe access to roofs, in the form of aerial appliances.
It has been pleasing to note the concepts of tactical ventilation, in part, have been adopted by the UK fire
service, and several other fire authorities around the world who have followed the ODPM guidelines.
However, there is still much to do in terms of ensuring clearer guidance of an integrated approach is
produced for firefighters in what remains, a somewhat 'grey' area of firefighting operations.
Firefighting Flow-rates - It was 1989 when I turned my attention to fire-ground flow-rates. Here was
an area that demonstrated much conflict and failed to produce what I saw then as reliable estimates of
needed fire flows. There were several fire-ground formulae that had evolved but were unsuitable in that they
were often derived from engineering design requirements (ie; more suited to fire protection needs) or were
based upon fire-flow-rate when used in a specific way, ie; indirect attack (Iowa) or direct attack (NFA). I was
searching for a general fire-ground method of estimating water requirements based upon practical
experience.
My initial research was based on a 100 fire study, in London, whilst serving as a fire investigator in 1990. The
fires were all working fires requiring assistance calls (additional engines) to complete suppression efforts. The
study was broadened to include several large fires in the USA where reliable fire-ground flow-rates were
derived. There appeared some interesting comparisons!
....'In theoretical terms of simply meeting a critical rate of flow, Sardqvist (1999) reports that this does not
offer the best use of resources, as it requires a more or less infinite time. An increase in the flow-rate above
the critical value causes a decrease in the total volume of water required to control the fire. However,
there exists an optimum flow giving the smallest total water volume. Above this flow, the total volume of
water increases again. In practical terms however, a margin of safety, or error, must be designed into the
application of any firefighting tactic and this includes methods of fire suppression and flow-rate. An
increase in water flow will generally darken a fire quicker. However, there is an upper limit on flow-rate in
terms of what is practical for any given size of fire, inline with the resources available on-scene during the
early stages of primary attack. The tactical flow-rate is the target flow (lpm) for a primary attack hose-
line/s. It is based upon extensive research and empirical data relating to firefighting flow-rates in several
countries, including the USA. The tactical flow-rate in this concept is for fire suppression during the growth
phases of development, or in post-flashover steady state enclosure fires before the decay-phase has been
reached'....
My basic formula for calculating the tactical flow-rate needed for firefighting is -
A x 4 = LPM
Where A = area in m2 and '4' is based upon ordinary (office) fire load although this may be reduced to 2 for
low hazard fire loads or increased to 6 for high hazard loads, or in situations where a fire has spread beyond
the original compartment to involve structural elements. The formula is only reliable for estimating the
minimum primary attack hose-line requirements in fires up to 600m2.
In 2004 I was most pleased that my original research was utilized by NZ Fire Engineer Cliff Barnett to amend
previously documented water efficiency factors in his SFPE research that culminated in the NZ SFPE TP
1/2004 document into firefighting flow-rates - an internationally accepted project that serves to establish
needed firefighting flow-rates.
This has resulted in new design concepts for fire protection and further serves to establish my research work
as the most reliable and up-to-date in terms of establishing fire-ground methods of estimating water
requirements for structural firefighting.
In Summary - Whilst it has often been frustrating that my demands for action were not met prior to many
of my colleagues losing their lives, it has been pleasing that nearly all of my research has eventually
benefited firefighters by improving their levels of safety and increasing their effectiveness on the fire-ground
in some way or other.