The document provides instructions for installing and using the Open-Vision 2.0 network management software. Open-Vision 2.0 includes utilities for switch configuration, topology viewing, host monitoring, and MIB browsing. It allows users to configure multiple switches simultaneously and monitor switch status. The document outlines system requirements, installation steps, and describes the main interfaces and functions of each Open-Vision 2.0 utility.

Uploaded by

oring2012
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
234 views154 pages

User Manual - Open-Vision 20

The document provides instructions for installing and using the Open-Vision 2.0 network management software. Open-Vision 2.0 includes utilities for switch configuration, topology viewing, host monitoring, and MIB browsing. It allows users to configure multiple switches simultaneously and monitor switch status. The document outlines system requirements, installation steps, and describes the main interfaces and functions of each Open-Vision 2.0 utility.

Uploaded by

oring2012
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 154

Industrial Ethernet Products

Management Utility

Open-Vision 2.0
User’s Manual

Version 1.0
June, 2009.

ORing Industrial Networking Corp.

4F., NO.3, Lane 235, Baociao Rd.Sindian City,

Taipei County 23145 Taiwan, R.O.C.

Tel: + 886 2 2918 3036

Fax: + 886 2 2918 3084

Website: www.oring-networking.com

E-mail: [email protected]
Open-Vision User’s Manual

Table of Content
Getting to Know Your Switch .............................................................................3
1.1 About the Open vision 2.0..............................................................3
1.2 Install Java machine .......................................................................4
1.3 System requirements......................................................................4
1.4 Prepare to install Open-Vision.......................................................5
Apply Open-Vision Commander to Switch Connection...............................11
2.1 Getting start to use Open-Vision Commander..........................11
2.2 Make sure PC’s Network setting.................................................12
2.3 How to discover different IP domain device?............................13
2.3.1 In the same broadcast domain....................................................13
2.3.2 In the different broadcast domain ...............................................14
2.4 Open-Vision Main interface .........................................................16
System Bar.........................................................................................................17
3.1 Task .................................................................................................17
3.2 Settings ...........................................................................................24
3.3 Help .................................................................................................24
Function Bar.......................................................................................................25
4.1 Icons Introduction ..........................................................................25
Switch Management Interface.........................................................................27
5.1 Devices ...........................................................................................27
5.2 Status Monitor ................................................................................28
5.3 Scan Devices Configuration ........................................................29
5.4 Syslog Events ................................................................................30
5.5 Wizards ...........................................................................................31
5.6 Group IP Setting Wizard ..............................................................31
5.7 Group Firmware Update Wizard .................................................34
5.8 Group O-Ring Setting Wizard......................................................37
Switch Function Interface.................................................................................40
6.1 Basic Setting ..................................................................................41
6.2 Basics & Port Configuration.........................................................42
6.3 Port Configuration .........................................................................62
6.4 Redundancy ...................................................................................67
6.4 RSTP...............................................................................................69
6.5 VLAN ...............................................................................................72
6.6 Traffic Prioritization........................................................................77

1
Open-Vision User’s Manual

6.7 IGMP Snooping .............................................................................82


6.8 SNMP Configuration .....................................................................84
6.9 Security ...........................................................................................90
6.10 Warning.........................................................................................100
6.11 Monitor and Diag .........................................................................108
6.12 LLDP..............................................................................................113
6.13 Save Configuration......................................................................113
Switch Status Interface...................................................................................115
7.1 The GUI for users to get switch status.....................................115
Switch Configuration Interface ......................................................................117
8.1 The relationship of function interface and the configuration
interfaces ...................................................................................................117
Topology View..................................................................................................118
9.1 About the Topology View............................................................118
9.2 Start to use Topology View.........................................................118
9.3 Topology View Main Interface ...................................................119
9.4 System Bar...................................................................................121
9.5 Function Bar.................................................................................133
9.6 Device Tree ..................................................................................134
9.7 Group Tree ...................................................................................137
9.8 Topology Area ..............................................................................139
9.9 System Log Area .........................................................................144
Host Monitor.....................................................................................................145
10.1 System Bar...................................................................................145
10.2 Function Bar.................................................................................147
10.3 Devices Tree ................................................................................148
10.4 Monitor Area.................................................................................151
MIB Brower.......................................................................................................151
TroubleShooting ..............................................................................................152
11.1 Why Topology View can not run in our computer?.................152
11.2 License key warning message ..................................................152
11.3 SYSLOG warning message.......................................................152
11.4 Why Topology View can not receive SNMP trap?...............153

2
Open-Vision User’s Manual

Getting to Know Your Switch


1.1 About the Open vision 2.0
Open vision 2.0 is ORing Industrial Networking Corp in 2009 year newly issued the powerful
software utility, his function surmounts. Open vision 2.0 includes four utilities
“Commander” 、 “Topology view” 、 ”Host monitor” 、 MIB Brower, With Open-Vision 2.0
Commander, user can set parameters to multiple switches at the same time. provides a
powerful interface for users to manage all switches in the network.
Open-Vision2.0 is not only a powerful utility for users to configure but also a useful utility for
monitoring. Users can monitor switches’ status via Host monitor. When the monitored
switches fail, the failure information will be displayed on Host monitoring interface.

Open-Vision 2.0

3
Open-Vision User’s Manual

1.2 Install Java machine


Please make sure if your computer if install JRE (if not ,Please download
Java Runtime Environment (JRE) 6 Update 3 from SUN
http://java.sun.com/javase/downloads/index.jsp.

1.3 System requirements

Minimum System RequirementsIV


„ Pentium IV or above (2.0 MHZ or above)
„ VGA Monitor with 1024 x 768 resolution
„ WINDOWS NT,2K ,2K3, XP
„ 512 MB RAM (1 GB recommended)
„ Java 2 Runtime Environment version 1.5
„ Internet Explorer 6.0 or higher
Supported Network Protocols
„ TCP / IP
„ UDP
„ SNMP
Operating System
Windows
„ NT
„ 2000
„ 2003
„ XP

4
Open-Vision User’s Manual

1.4 Prepare to install Open-Vision

Before using Open-Vision, users need to install the utility first.


Double click Open-Vision.exe, started the install process.

Step 1
After execution of Open-Vision2.0.exe, the Operation System start to install
Open-Vision2.0

5
Open-Vision User’s Manual

Step 2
Click [Next] to continue setup process.

6
Open-Vision User’s Manual

Step 3
Users are able to change the path that they want to install in.

Click to change the path.

When click , users can configure the path that they want to install

from the pop-up windows.

7
Open-Vision User’s Manual

Step 4
Completed the path, and then click [Next]

8
Open-Vision User’s Manual

Step 5
Please double check the installing information of this page. If everything is
correct, then click “Install.”

9
Open-Vision User’s Manual

Step 6
When the Installation process is finished, click “Finish” to complete the
Installing process.

10
Open-Vision User’s Manual

Apply Open-Vision Commander to


Switch Connection

2.1 Getting start to use Open-Vision


Commander

Select 「Start」→「All Programs」→「Open-Vision」→「commander」


to execute Open-Vision2.0.

11
Open-Vision User’s Manual

2.2 Make sure PC’s Network setting


First of all, double check the configuration of the PC’s IP address, Subnet
mask, Default gateway…etc., and make sure the PC is connected to Default
Gateway and the switch you wish to connect properly.

12
Open-Vision User’s Manual

2.3 How to discover different IP domain


device?

2.3.1 In the same broadcast domain


When the monitored PC and the managed switches are within the same
broadcast domain, as illustrated by Figure 1-1,

Figure 1-1

Click「Discovery」directly on the Open-Vision to search the switches.

13
Open-Vision User’s Manual

2.3.2 In the different broadcast domain


If the monitored PC and the managed switches are in different broadcast
domain, as illustrated by Figure 2-2, then users need to use the advanced
search function to search the switches.

Figure 2-2

Make sure the PC is connected to Default Gateway and the switch you
wish to connect properly.

If the Network is proper, open Open-Vision, and click “Discovery Filter.”

14
Open-Vision User’s Manual

Select “Remote” and a window open up as shown below.

Insert the Switch IP Address range you wish to search and click , the
IP address will be added automatically as shown in the diagram above. Click
“ok” to start the searching of switch.

And the switches in different network will be found by Open-Vision.

15
Open-Vision User’s Manual

2.4 Open-Vision Main interface

The Open-Vision main interface shows as below:


System Bar
Function Bar
Switch Management Interface
Switch Function Interface
Switch Status Interface
Switch Configuration Interface

16
Open-Vision User’s Manual

System Bar
3.1 Task
User can select task to show Open-Vision tasks menu.

Task Hotkey Description


Click Discovery or Ctrl + D to discover the switches on
the same subnet. Open-Vision will display all discovered
switches on the management interface. Open-Vision
Discovery Ctrl + D discovers switched depend on discovery filter shows as
next task. Note: all switches can be the same IP
address. Open-Vision can discover and change IP by
the Group IP Setting function.

Discovering switches displayed on management interface.

17
Open-Vision User’s Manual

Task Hotkey Description


• Local Subnets: Open-Vision will only
discover all switches connect to the
specific IP of NIC that user select.

• Primary Interface/Gateway/Default Route:


Open-Vision will select a primary interface
Discovery to discover switches.
Ctrl + F
Filter
• Customize: Set up the subnet to filter, user
also can define a smaller rage in the
subnet to filter. When use Remote
function, users are able to use specific IP
addresses to discover switches.

18
Open-Vision User’s Manual

• Local Subnets: Open-Vision will only discover all switches connect to the
specific IP of NIC that user select.

• Primary Interface/Gateway/Default Route: Open-Vision will select a


primary interface to discover switches.

19
Open-Vision User’s Manual

Customize: Set up the subnet to filter, user also can define a smaller rage in
the subnet to filter. When use Remote function, users are able to use specific
IP addresses to discover switches.

Task Hotkey Description

Select switch to login to configure. Open-Vision


can login to multiple switches that user selected.
Enter account and password to login (the same
Login Ctrl + L with web management). Note: When user login
and idle about 300 seconds, Open-Vision will
logout automatically. When login success, the
switch icon will change from to .

20
Open-Vision User’s Manual

Login Interface

Task Hotkey Description


Select switch to logout. Open-Vision can
logout from multiple switches that user
Logout N/A
selected. When logout success, the switch
icon will change from to. .

21
Open-Vision User’s Manual

Task Hotkey Description


The user can define the time of logout by
Autologout oneself, improve the software security.
N/A
Time

Task Hotkey Description


Select switch to reboot. Open-Vision can
reboot multiple switches that user selected.
Reboot Ctrl + B
When user click reboot, a dialog window will
be displayed on screen for confirming.

22
Open-Vision User’s Manual

Task Hotkey Description

Select switch to open web UI management.


Open Web Ctrl + W Open-Vision will open browser of your OS
automatically.

Task Description
Refresh the specific switch function management
Refresh
interface and switch configuration interface.
Refresh all switch function management interfaces
Refresh All
and switch configuration interfaces

23
Open-Vision User’s Manual

3.2 Settings

Task Description

Load Config Users are able to re-load the IP address list.


Users are able to save the IP address list on the
Save Config
Discovery Filter/Remote page.

3.3 Help

Label Hotkey Description


Show Open-Vision version
About F1
information.

24
Open-Vision User’s Manual

Function Bar
4.1 Icons Introduction
There are many icons on function bar. The functions of the icons are the same
with Tasks that we introduce in previous chapter.

Icon Description

Same with task “Discovery”.

Same with task “Discovery Filter”.

Same with task “Login”.

Same with task “Logout”.

Same with task “Reboot”.

Same with task “Open Web”.

Same with task “Refresh”.

Same with task “Refresh All”.

One of Open-Vision powerful functions.


Open-Vision Group IP Wizard can configure multiple
switches’ IP Address. The function will be
introduced more detail in Switch Management
Interface chapter.

25
Open-Vision User’s Manual

One of Open-Vision powerful functions.


Open-Vision Group IP Wizard can update multiple
switches’ firmware. The function will be introduced
more detail in Switch Management Interface
chapter.
One of Open-Vision powerful functions.
Open-Vision Group O-Ring Wizard can setting
multiple switches’ O-Ring Function. The function will
be introduced more detail in Switch Management
Interface chapter.

Same with task “about”.

26
Open-Vision User’s Manual

Switch Management Interface


5.1 Devices
User can see and manage all discovered switches by the device function.
User can select wanted switch to execute tasks.

Switch Management Interface

Label Description

Devices Show the amount of discovered switches.

All Devices Show all discovered switches’ detail information.

27
Open-Vision User’s Manual

5.2 Status Monitor


Status Monitor provides user to monitor multi switches in a page. Through
the color changes, user can know something happened to switches, then tack
action to repair the situation.

Status Monitor Interface

Label Description
The period that Open-Vision will send a packet to device to
Query Period
query status.
Set the timeout period. After the period, Open-Vision does not
Query Timeout
receive reply from device, warning message will be displayed.
Mark the blank for beep alarm. Open-Vision will let your PC
Beep Alarm
make sound to inform user that some events happen.
When switch breaks down, Our can direct change switch, then
Change error push " change error Devices " , commander utility will
Devices upgrade breaks down switch that information , Let new switch
replace bad switch
When the devices does not exist, we can utilize " delete
Delete Selected
selected Devices " to delete in list not existing the device
Devices
information
Refresh Refresh the status.
IP Show the IP Address of discovered switch.
MAC Address Show the MAC Address of discovered switch.
Model Show the Model name of discovered switch.
Last Reported Show the last time that Open-Vision receives report from
Time switch.
Status Show switch online/offline and show events alarm.

28
Open-Vision User’s Manual

Open The user can oneself define ALARM sound file.(MP3, WAV)

5.3 Scan Devices Configuration


"Scan Devices Configuration" function, can scan config to compare device
config with backup config,Guarantee the exactness of device cofnig. Avoid the
artificial establishment mistake.

Label Description

Source Directory Show the amount of discovered switches.

Auto Scan Show all discovered switches’ detail information.

Every hour Enable, every hour will automatic scan device config
Enable, the time to appoint every day, will automatic scan
Every day
device config
Scan Now Star Scan devices configuration function

Model Show device model name

Kernel Ver Show device firmware kernel ver

Firmware Ver Show device firmware ver

IP Address Show device the IP Address

Status Show device config check status

Filename Show device config filename

29
Open-Vision User’s Manual

5.4 Syslog Events


Commander utility has a built-in syslog server. User does not need to use
other syslog software. In syslog event window, the events will be record and
user can know what event happened to the switches.

Syslog events Interface

Label Description
According to threshold number setting , carry out save movement,
Auto Save when system log exceeds the threshold number , commander
utility will auto save system log file to excel file.
Threshold num Auto save 的檔案數量

Save Save system log info to excel file

clear Clear all system log

Event ID The number of the happened event.

Facility Class of the event.

Severity Show the event urgent degree.

Host Show the event source address.

Date Show the date of the happened event.

Time Show detail time of the happened event.

Port Show connect port

Link state Show link status

30
Open-Vision User’s Manual

Messages Show switch status

5.5 Wizards
A friendly UI of Open-Vision to help user to set IP address or update
firmware of a group of switch. The wizard lets users step by step to do the jobs.
It is very convenient for network administrator to save time for configuring IP
and updating firmware. Besides saving time, it can also reduce the mistakes
made by user.

Wizard Interface

5.6 Group IP Setting Wizard


Group IP Setting Wizard helps you walk through whole IP address configure
process of a group of devices. A few steps would be taken during this process:

31
Open-Vision User’s Manual

Group IP Setting Wizard Interface


STEP: 1. Select one or more devices to be configured.

STEP: 2. Configure the IP address range or DHCP IP address

32
Open-Vision User’s Manual

STEP: 3. Apply settings

STEP: 4. Verify the IP Setting by wizard.

33
Open-Vision User’s Manual

5.7 Group Firmware Update Wizard


This wizard helps you to update firmware for a group of devices.

Group Firmware Update Wizard Interface

34
Open-Vision User’s Manual

STEP: 1. Select one or more devices to be configured.

STEP: 2. Select the upgrade method, local firmware image or remote tftp
server.

35
Open-Vision User’s Manual

STEP: 3. Apply to upgrade selected firmware

STEP: 4. Reboot the switch that was upgraded firmware.

36
Open-Vision User’s Manual

5.8 Group O-Ring Setting Wizard


This wizard helps you to most easy setting O-Ring for a group of devices.

Group O-Ring Setting Wizard Interface

STEP: 1. Select one or more devices to be configured.

37
Open-Vision User’s Manual

STEP: 2. Select want to carry out Ring Function to port number

38
Open-Vision User’s Manual

STEP: 3. O-Ring Function sets up successfully

39
Open-Vision User’s Manual

Switch Function Interface


The function interface is the same with function tree on web UI. That means:
all functions can be configure on web; they can also configured by
Open-Vision.

Functions Interface and Tree on Open-Vision and WEB

40
Open-Vision User’s Manual

6.1 Basic Setting


6.1.1 System login
System Login
1. Launch the Open-Vision
2. To get into Basics
3. The login screen appears.
4. Key in the username and password. The default username and
password is “admin”.
5. Click “Enter” or ”Login” button, then the main interface of the
Web-based management appears.

WEB Login screen

41
Open-Vision User’s Manual

6.2 Basics & Port Configuration


6.2.1 Switch setting

Switch setting interface

The following table describes the labels in this screen.


Label Description
Assign the name of switch. The maximum length is 64
System Name
bytes
System
Display the description of switch.
Description
System Assign the switch physical location. The maximum
Location length is 64 bytes

42
Open-Vision User’s Manual

System
Enter the name of contact person or organization
Contact
Firmware
Display the switch’s firmware version
Version
Kernel Version Display the kernel software version

Display the unique hardware address assigned by


MAC Address
manufacturer (default)

6.2.2 Admin Password


Change Open-Vision management login username and password for the
management security issue

Admin Password interface

43
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description

User name Key in the new username(The default is “admin”)

New
Key in the new password(The default is “admin”)
Password

Confirm Re-type the new password.


password

Apply Click “Apply” to set the configurations.

IP configuration
You can configure the IP Settings and DHCP client function through IP
configuration.

IP Configuration interface

44
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description
To enable or disable the DHCP client function. When DHCP
client function is enabling, the switch will be assigned the IP
address from the network DHCP server. The default IP
address will be replaced by the IP address which the DHCP
DHCP Client
server has assigned. After clicking “Apply” button, a popup
dialog show up to inform the you when the DHCP client is
enabling. The current IP will lose and you should find a new IP
on the DHCP server.

Assign the IP address that the network is using. If DHCP client


function is enabling, you do not need to assign the IP address.
IP Address The network DHCP server will assign the IP address for the
switch and it will be display in this column. The default IP is
192.168.10.1
Assign the subnet mask of the IP address. If DHCP client
Subnet Mask
function is enabling, you do not need to assign the subnet mask

Assign the network gateway for the switch. The default


Gateway
gateway is 192.168.10.254
DNS1 Assign the primary DNS IP address
DNS2 Assign the secondary DNS IP address
Apply Click “Apply” to set the configurations.

45
Open-Vision User’s Manual

SNTP Configuration
The SNTP (Simple Network Time Protocol) settings allow you to synchronize
switch clocks in the Internet.

SNTP Configuration interface

46
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description
Enable or disable SNTP function to get the time from the
SNTP Client
SNTP server.

Enable or disable daylight saving time function. When


Daylight daylight saving time is enabling, you need to configure the
Saving Time
daylight saving time period.

UTC Time Set the switch location time zone. The following table lists
zone the different location time zone for your reference.

Local Time Zone Conversion from UTC Time at 12:00 UTC


November Time Zone - 1 hour 11 am
Oscar Time Zone -2 hours 10 am
ADT - Atlantic Daylight -3 hours 9 am
AST - Atlantic
Standard
-4 hours 8 am
EDT - Eastern
Daylight
EST - Eastern
Standard -5 hours 7 am
CDT - Central Daylight
CST - Central
Standard
-6 hours 6 am
MDT - Mountain
Daylight
MST - Mountain
Standard -7 hours 5 am
PDT - Pacific Daylight
PST - Pacific Standard
ADT - Alaskan -8 hours 4 am
Daylight

47
Open-Vision User’s Manual

ALA - Alaskan
-9 hours 3 am
Standard
HAW - Hawaiian
-10 hours 2 am
Standard
Nome, Alaska -11 hours 1 am
CET - Central
European
FWT - French Winter
MET - Middle
+1 hour 1 pm
European
MEWT - Middle
European Winter
SWT - Swedish Winter
EET - Eastern
European, USSR +2 hours 2 pm
Zone 1
BT - Baghdad, USSR
+3 hours 3 pm
Zone 2
ZP4 - USSR Zone 3 +4 hours 4 pm
ZP5 - USSR Zone 4 +5 hours 5 pm
Local Time Zone Conversion from UTC Time at 12:00 UTC
ZP6 - USSR Zone 5 +6 hours 6 pm
WAST - West
+7 hours 7 pm
Australian Standard
CCT - China Coast,
+8 hours 8 pm
USSR Zone 7
JST - Japan Standard,
+9 hours 9 pm
USSR Zone 8
EAST - East
Australian Standard
GST +10 hours 10 pm
Guam Standard,
USSR Zone 9

48
Open-Vision User’s Manual

IDLE - International
Date Line
NZST - New Zealand +12 hours Midnight
Standard
NZT - New Zealand

Label Description

SNTP Sever Set the SNTP server IP address.


IP Address

Daylight Set up the Daylight Saving beginning time and Daylight


Saving Period Saving ending time. Both will be different each year.

Daylight Set up the offset time.


Saving Offset

Switch Timer Display the switch current time.

Apply Click “Apply” to set the configurations.

DHCP Server

DHCP Server – Configuration


The system provides with DHCP server function. Enable the DHCP server
function, the switch system will be a DHCP server.

49
Open-Vision User’s Manual

DHCP Server Configuration interface

The following table describes the labels in this screen.


Label Description
Enable or Disable the DHCP Server function. Enable – the
DHCP Server
switch will be the DHCP server on your local network
The dynamic IP assign range. Low IP address is the beginning

Start IP of the dynamic IP assigns range. For example: dynamic IP


Address assign range is from 192.168.1.100 to 192.168.1.200.
192.168.1.100 will be the Start IP address.
The dynamic IP assign range. High IP address is the end of
End IP
the dynamic IP assigns range. For example: dynamic IP
Address
assign range is from 192.168.1.100 to 192.168.1.200.

50
Open-Vision User’s Manual

192.168.1.200 will be the End IP address

Subnet Mask The dynamic IP assign range subnet mask

Gateway The gateway in your network.

DNS Domain Name Server IP Address in your network.

Lease Time It is the period that system will reset the assigned dynamic IP to
(Hour) ensure the IP address is in used.

Apply Click “Apply” to set the configurations.

DHCP Server – Client Entries


When the DHCP server function is activated, the system will collect the
DHCP client information and display in here.

DHCP Server Client Entries interface

51
Open-Vision User’s Manual

DHCP Server – Port and IP bindings


You can assign the specific IP address which is in the assigned dynamic IP
range to the specific port. When the device is connecting to the port and asks
for dynamic IP assigning, the system will assign the IP address that has been
assigned before in the connected device.

DHCP Server Port and IP Binding interface

52
Open-Vision User’s Manual

Backup & Restore


You can save current EEPROM value from the switch to TFTP server, then
go to the TFTP restore configuration page to restore the EEPROM value.

Use build-in support Backup

53
Open-Vision User’s Manual

Use remote tftp server Backup

54
Open-Vision User’s Manual

Use build-in support Restore

55
Open-Vision User’s Manual

Use remote tftp server Restore

The following table describes the labels in this screen.


Label Description
TFTP Server IP Fill in the TFTP server IP
Address

Restore File Name Fill the file name.

Restore Click “restore” to restore the configurations.

Restore File Name Fill the file name.

56
Open-Vision User’s Manual

Restore Click “restore” to restore the configurations.

Backup Click “backup” to backup the configurations.

Upgrade Firmware
Upgrade Firmware allows you to update the switch firmware. Before
updating, make sure you have your TFTP server ready and the firmware image
is on the TFTP server.

Use build-in support Upgrade

57
Open-Vision User’s Manual

Use remote tftp server Upgrade

58
Open-Vision User’s Manual

Auto Provision
Auto Provision allows you to update the switch firmware automatically. You
can put firmware or configuration file on TFTP server. When you reboot the
switch, it will upgrade automatically. Before updating, make sure you have
your TFTP server ready and the firmware image and configuration file is on the
TFTP server.

Auto Provision interface

59
Open-Vision User’s Manual

Factory Default

Factory Default interface

Reset switch to default configuration. Click “Apply” to reset all


configurations to the default value. You can select “Keep current IP
address setting” and “Keep current username & password” to prevent IP
and username and password form default.

60
Open-Vision User’s Manual

System Reboot

System Reboot interface

61
Open-Vision User’s Manual

6.3 Port Configuration


6.3.1 Port Control
By this function, you can set the state, speed/duplex, flow control, and security
of the port.

Port Control interface

The following table describes the labels in this screen.


Label Description

Port NO. Port number for setting.

State Enable or Disable Port Control function

You can set Autonigotiation,100 full ,100 half,10


Speed/Duplex
full,10 half mode.

Support symmetric and asymmetric mode to avoid


Flow Control
packet loss when congestion occurred.

62
Open-Vision User’s Manual

Support port security function. When enable the

Security function, the port will STOP learning MAC address


dynamically.

Apply Click “Apply” to set the configurations.

6.3.2 Port Status


The following information provides the current port status information

Port Status interface

6.3.3 Rate Limit


By this function, You can limit traffic of all ports, including broadcast,
multicast and flooded unicast. You can also set “Ingress” or “Egress” to limit
traffic received or transmitted bandwidth.

63
Open-Vision User’s Manual

Rate Limit interface

The following table describes the labels in this screen.


Label Description
You can set “all”, “Broadcast
Ingress Limit Frame only”, ”Broadcast/Multicast”
Type
or ”Broadcast/Multicast/Flooded Unicast” mode.

Ingress The switch port received traffic.

Egress The switch port transmitted traffic.

Apply Click “Apply” to set the configurations.

64
Open-Vision User’s Manual

Port Trunk

Port Trunk – Setting


You can select static trunk or 802.3ad LACP to combine several physical link
with a logical link to increase the bandwidth

Port Trunk - Setting interface

The following table describes the labels in this screen.


Label Description
Group ID Select port to join a trunk group.

Type Support static trunk and 802.3ad LACP

Apply Click “Apply” to set the configurations.

65
Open-Vision User’s Manual

Port Trunk – Status

Port Trunk - Status interface

66
Open-Vision User’s Manual

6.4 Redundancy
6.4.1 O-Ring
O-Ring is the most powerful Ring in the world. The recovery time of O-Ring
is less than 10 mS. It can reduce unexpected damage caused by network
topology change. O-Ring Supports 3 Ring topology: O-Ring, Coupling Ring
and Dual Homing.

O-Ring interface

The following table describes the labels in this screen.


Label Description
O-Ring Mark to enable Ring.
There should be one and only one Ring Master in a

Ring Master ring. However if there are two or more switches


which set Ring Master to enable, the switch with the

67
Open-Vision User’s Manual

lowest MAC address will be the actual Ring Master


and others will be Backup Masters.

1st Ring Port The primary port, when this switch is Ring Master.

2nd Ring Port The backup port, when this switch is Ring Master.
Mark to enable Coupling Ring. Coupling Ring can
be used to divide a big ring into two smaller rings to

Coupling Ring avoid effecting all switches when network topology


change. It is a good application for connecting two
Rings.
Label Description
Link to Coupling Port of the switch in another ring.
Coupling Ring need four switch to build an active

Coupling Port and a backup link.


Set a port as coupling port. The coupled four ports
of four switches will be run at active/backup mode.
Link to Control Port of the switch in the same ring.
Control Port
Control Port used to transmit control signals.
Mark to enable Dual Homing. By selecting Dual
Homing mode, O-Ring will be connected to normal
switches through two RSTP links (ex: backbone
Dual Homing
Switch). The two links work as active/backup
mode, and connect each O-Ring to the normal
switches in RSTP mode.

Apply Click “Apply” to set the configurations.

Note: We don’t suggest you to set one switch as a Ring Master and a Coupling Ring at the same time
due to heavy load.

68
Open-Vision User’s Manual

6.4 RSTP
The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning
Tree Protocol. It provides faster spanning tree convergence after a topology
change. The system also supports STP and the system will auto detect the
connected device that is running STP or RSTP protocol.

RSTP setting
You can enable/disable RSTP function, and set parameters for each port.

RSTP Setting interface

The following table describes the labels in this screen.


Label Description
You must enable or disable RSTP function before
RSTP mode
configuring the related parameters.
A value used to identify the root bridge. The bridge

Priority (0-61440) with the lowest value has the highest priority and is
selected as the root. If the value changes, You

69
Open-Vision User’s Manual

must reboot the switch. The value must be


multiple of 4096 according to the protocol standard
rule.
The number of seconds a bridge waits without
receiving Spanning-tree Protocol configuration
Max Age (6-40)
messages before attempting a reconfiguration.
Enter a value between 6 through 40.
The time that controls switch sends out the BPDU

Hello Time (1-10) packet to check RSTP current status. Enter a


value between 1 through 10.
The number of seconds a port waits before

Forwarding Delay changing from its Rapid Spanning-Tree Protocol


Time (4-30) learning and listening states to the forwarding state.
Enter a value between 4 through 30.
The cost of the path to the other bridge from this
Path Cost transmitting bridge at the specified port. Enter a
(1-200000000)
number 1 through 200000000.
Decide which port should be blocked by priority in

Priority (0-240) LAN. Enter a number 0 through 240. The value


of priority must be the multiple of 16
Some of the rapid state transactions that are
possible within RSTP are dependent upon whether
the port concerned can only be connected to exactly
one other bridge (i.e. It is served by a point-to-point
LAN segment), or it can be connected to two or
Admin P2P
more bridges (i.e. It is served by a shared medium
LAN segment). This function allows the P2P status
of the link to be manipulated administratively. True
means P2P enabling. False means P2P disabling.

The port directly connected to end stations, and it


Admin Edge
cannot create bridging loop in the network. To

70
Open-Vision User’s Manual

configure the port as an edge port, set the port to


“True”.
The port includes the STP mathematic calculation.

Admin Non STP True is not including STP mathematic calculation.


False is including the STP mathematic calculation.

Apply Click “Apply” to set the configurations.


NOTE: Follow the rule to configure the MAX Age, Hello Time, and Forward Delay Time.
2 x (Forward Delay Time value –1) > = Max Age value >= 2 x (Hello Time value +1)

RSTP Information
Show RSTP algorithm result at this table.

RSTP Information interface

71
Open-Vision User’s Manual

6.5 VLAN
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast
domain, which allows you to isolate network traffic. Only the members of the
VLAN will receive traffic from the same members of VLAN. Basically, creating
a VLAN from a switch is logically equivalent of reconnecting a group of network
devices to another Layer 2 switch. However, all the network devices are still
plugged into the same switch physically.

The switch supports port-based and 802.1Q (tagged-based) VLAN. The


default configuration of VLAN operation mode is at “802.1Q”.

VLAN Configuration – 802.1Q

Tagged-based VLAN is an IEEE 802.1Q specification standard, and t is


possible to create a VLAN across devices from different switch venders.
IEEE 802.1Q VLAN uses a technique to insert a “tag” into the Ethernet frames.
Tag contains a VLAN Identifier (VID) that indicates the VLAN numbers.

You can create Tag-based VLAN, and enable or disable GVRP protocol.
There are 256 VLAN groups to provide configure. Enable 802.1Q VLAN, the
all ports on the switch belong to default VLAN, VID is 1. The default VLAN
cannot be deleted.

GVRP allows automatic VLAN configuration between the switch and nodes.
If the switch is connected to a device with GVRP enabled, you can send a
GVRP request by using the VID of a VLAN defined on the switch; the switch
will automatically add that device to the existing VLAN.

72
Open-Vision User’s Manual

VLAN Configuration

VLAN Configuration – 802.1Q interface

The following table describes the labels in this screen.


Label Description

VLAN Operation Configure VLAN Operation Mode: disable, Port


Mode Base,802.1Q

GVRP Mode Enable/Disable GVRP function.


Management VLAN can provide network

Management VLAN administrator a secure VLAN to management


ID Switch. Only the devices in the management
VLAN can access the switch.

73
Open-Vision User’s Manual

There are 3 types of link type:


Access Link: single switch only, allows you to group
ports by setting the same VID.
Trunk Link: extended application of Access Link,
Link type
allows you to group ports by setting the same VID
with 2 or more switches.
Hybrid Link: Both Access Link and Trunk Link are
available.

Set the port default VLAN ID for untagged devices


Untagged VID
that connect to the port. The range is 1 to 4094.

Set the tagged VIDs to carry different VLAN frames


Tagged VIDs
to other switch.

Apply Click “Apply” to set the configurations.

74
Open-Vision User’s Manual

VLAN Configuration – Port Based


Packets can go among only members of the same VLAN group. Note all
unselected ports are treated as belonging to another single VLAN. If the
port-based VLAN enabled, the VLAN-tagging is ignored.

VLAN Configuration – Port Base interface

The following table describes the labels in this screen.


Label Description

Add Click “add” to enter VLAN add interface.

Edit Edit exist VLAN

75
Open-Vision User’s Manual

Delete Delete exist VLAN

Help Show help file.

The following table describes the labels in this screen.


Label Description

Group Name VLAN name.

VLAN ID Specify the VLAN ID

Add Select port to join the VLAN group.

Remove Remove port of the VLAN group

Apply Click “Apply” to set the configurations.

Help Show help file.

76
Open-Vision User’s Manual

6.6 Traffic Prioritization


Traffic Prioritization includes 3 modes: port base, 802.1p/COS, and
TOS/DSCP. By traffic prioritization function, you can classify the traffic into
four classes for differential network application. SW-M series support 4
priority queues.

Qos Policy Interface

77
Open-Vision User’s Manual

Port Based Priority Interface

78
Open-Vision User’s Manual

COS Setting Interface

79
Open-Vision User’s Manual

TOS Setting Interface

The following table describes the labels in this screen.


Label Description
„ Using the 8,4,2,1 weight fair queue scheme: the
output queues will follow 8:4:2:1 ratio to transmit
packets from the highest to lowest queue. For
QOS policy
example: 8 high queue packets, 4 middle queue
packets, 2 low queue packets, and the one lowest
queue packets are transmitted in one turn.

80
Open-Vision User’s Manual

„ Use the strict priority scheme: always the packets


in higher queue will be transmitted first until higher
queue is empty.
„ Port-base: the output priority is determined by
ingress port.
„ COS only: the output priority is determined by COS
only.
„ TOS only: the output priority is determined by TOS
Priority Type
only.
„ COS first: the output priority is determined by COS
and TOS, but COS first.
„ TOS first: the output priority is determined by COS
and TOS, but TOS first.
Assign Port with a priority queue. 4 priority queues can
Port base Priority
be assigned: High, Middle, Low, and Lowest.
COS (Class Of Service) is well known as 802.1p. It
describes that the output priority of a packet is

COS/802.1p determined by user priority field in 802.1Q VLAN tag.


The priority value is supported 0to7.COS value map to 4
priority queues: High, Middle, Low, and Lowest.
When an ingress packet has not VLAN tag, a default

COS Port Default priority value is considered and determined by ingress


port.
TOS (Type of Service) is a field in IP header of a packet.
This TOS field is also used by Differentiated Services
and is called the Differentiated Services Code Point

TOS/DSCP (DSCP). The output priority of a packet can be


determined by this field and the priority value is
supported 0to63. DSCP value map to 4 priority queues:
High, Middle, Low, and Lowest.

Apply Click “Apply” to set the configurations.

Help Show help file.

81
Open-Vision User’s Manual

6.7 IGMP Snooping


Internet Group Management Protocol (IGMP) is used by IP hosts to register
their dynamic multicast group membership. IGMP has 3 versions, IGMP v1,
v2 and v3. Please refer to RFC 1112, 2236 and 3376. IGMP Snooping
improves the performance of networks that carry multicast traffic. It provides
the ability to prune multicast traffic so that it travels only to those end
destinations that require that traffic and reduces the amount of traffic on the
Ethernet LAN.

IGMP Snooping interface

82
Open-Vision User’s Manual

IGMP Snooping Table Interface

The following table describes the labels in this screen.


Label Description

IGMP Snooping Enable/Disable IGMP snooping.

Switch will be IGMP querier or not. There should


exist one and only one IGMP querier in an IGMP
IGMP Query Mode
application. The "Auto" mode means that the
querier is the one with lower IP address.

IGMP Snooping Show current IP multicast list


Table

Apply Click “Apply” to set the configurations.

Help Show help file.

83
Open-Vision User’s Manual

6.8 SNMP Configuration


Simple Network Management Protocol (SNMP) is the protocol developed to
manage nodes (servers, workstations, routers, switches and hubs etc.) on an
IP network. SNMP enables network administrators to manage network
performance, find and solve network problems, and plan for network growth.
Network management systems learn of problems by receiving traps or change
notices from network devices implementing SNMP.

SNMP –Agent Setting


You can set SNMP agent related information by Agent Setting Function.

SNMP Agent Setting interface

84
Open-Vision User’s Manual

SNMP Community Interface

85
Open-Vision User’s Manual

SNMP v3 User Interface

The following table describes the labels in this screen.


Label Description
Three SNMP versions are supported such as SNMP
V1/SNMP V2c, and SNMP V3. SNMP V1/SNMP
V2c agent use a community string match for
SNMP agent
authentication, that means SNMP servers access
Version
objects with read-only or read/write permissions
with the community default string public/private.
SNMP V3 requires an authentication level of MD5 or

86
Open-Vision User’s Manual

DES to encrypt data to enhance data security.


SNMP Community should be set for SNMP V1/V2c.
Four sets of "Community String/Privilege" are
SNMP V1/V2c
supported. Each Community String is maximum
Community
32 characters. Keep empty to remove this
Community string.
If SNMP V3 agent is selected, the SNMPv3 you
profiled should be set for authentication. The
Username is necessary. The Auth Password is
encrypted by MD5 and the Privacy Password which
is encrypted by DES. There are maximum 8 sets
of SNMPv3 User and maximum 16 characters in
username, and password.

When SNMP V3 agent is selected, you can:

1. Input SNMPv3 username only.


2. Input SNMPv3 username and Auth
SNMPv3User Password.
3. Input SNMPv3 username, Auth
Password and Privacy Password,
which can be different with Auth
Password.

To remove a current user profile:

1. Input SNMPv3 user name you want to


remove.
2. Click "Remove" button

Current SNMPv3 Show all SNMPv3 user profiles.


User Profile
Apply Click “Apply” to set the configurations.

Help Show help file.

87
Open-Vision User’s Manual

SNMP –Trap Setting


A trap manager is a management station that receives traps, the system
alerts generated by the switch. If no trap manager is defined, no traps will
issue. Create a trap manager by entering the IP address of the station and a
community string. To define management stations as trap manager and enter
SNMP community strings and selects the SNMP version.

SNMP Trap Setting Interface

88
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description

Server IP The server IP address to receive Trap

Community Community for authentication

Trap Version Trap Version supports V1 and V2c.

Add Add trap server profile.

Remove Remove trap server profile.

Help Show help file.

89
Open-Vision User’s Manual

6.9 Security
Five useful functions can enhance security of switch: IP Security, Port Security,
MAC Blacklist, and MAC address Aging and 802.1x protocol.

IP Security
Only IP in the Secure IP List can manage the switch through your defined
management mode. ( WEB, Telnet, SNMP)

IP Security interface

90
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description
IP security MODE Enable/Disable the IP security function.
Enable WEB Mark the blank to enable WEB Management.
Management
Enable Telnet Mark the blank to enable Telnet Management.
Management
Enable SNMP Mark the blank to enable MPSN Management.
Management
Apply Click “Apply” to set the configurations.

Help Show help file.

91
Open-Vision User’s Manual

Port Security
Port security is to add static MAC addresses to hardware forwarding database.
If port security is enabled at Port Control page, only the frames with MAC
addresses in this list will be forwarded, otherwise will be discarded.

Port Security interface

92
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description

MAC Address Input MAC Address to a specific port.

Port NO. Select port of switch.

Add Add an entry of MAC and port information.

Delete Delete the entry.

Help Show help file.

93
Open-Vision User’s Manual

MAC Blacklist
MAC Blacklist can eliminate the traffic forwarding to specific MAC addresses
in list. Any frames forwarding to MAC addresses in this list will be discarded.
Thus the target device will never receive any frame.

MAC Blacklist interface

The following table describes the labels in this screen.


Label Description

MAC Address Input MAC Address to add to MAC Blacklist.

Port NO. Select port of switch.

94
Open-Vision User’s Manual

Add Add an entry to Blacklist table.

Delete Delete the entry.

Help Show help file.

MAC Address Aging


You can set MAC Address aging timer, as time expired, the unused MAC will
be cleared from MAC table. SW-M series also support Auto Flush MAC
Address Table When ports Link Down.

MAC Address Aging interface

The following table describes the labels in this screen.


Label Description

MAC Address Table


Aging Time: Set the timer.
(0to3825)

95
Open-Vision User’s Manual

Auto Flush MAC


Address Table Mark the blank to enable the function,
When ports Link
Down.
Apply Click “Apply” to set the configurations.

Help Show help file.

802.1x
802.1x - Radius Server
802.1x makes the use of the physical access characteristics of IEEE802
LAN infrastructures in order to provide a authenticated and authorized devices
attached to a LAN port. Please refer to IEEE 802.1X - Port Based Network
Access Control.

802.1x Radius Server interface

96
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description
Radius Server
Setting
Radius Server IP The IP address of the authentication server.
Set the UDP port number used by the authentication
Server port
server to authenticate.
Set the UDP destination port for accounting requests to
Account port
the specified Radius Server.
A key shared between this switch and authentication
Shared Key
server.

NAS, Identifier A string used to identify this switch.


Advanced Setting
Set the time interval between authentication failure and
Quiet Period
the start of a new authentication attempt.
Set the time that the switch can wait for response to an

Tx Period EAP request/identity frame from the client before


resending the request.

Supplicant Set the period of time the switch waits for a supplicant
Timeout response to an EAP request.
Set the period of time the switch waits for a Radius server
Server Timeout
response to an authentication request.
Set the maximum number of times to retry sending
Max Requests
packets to the supplicant.
Set the period of time after which clients connected must
Re-Auth Period
be re-authenticated.

Apply Click “Apply” to set the configurations.

Help Show help file.

97
Open-Vision User’s Manual

802.1x-Port Authorized Mode


Set the 802.1x authorized mode of each port.

802.1x Port Authorize interface

The following table describes the labels in this screen.


Label Description
„ Reject: force this port to be unauthorized.
Port Authorized
„ Accept: force this port to be authorized.
Mode
„ Authorize: the state of this port was

98
Open-Vision User’s Manual

determined by the outcome of the 802.1x


authentication.
„ Disable: this port will not participate in
802.1x.

Apply Click “Apply” to set the configurations.

Help Show help file.

802.1x-Port Authorized Mode


Show 802.1x port authorized state.

802.1x Port Authorize State interface

99
Open-Vision User’s Manual

6.10 Warning
Warning function is very important for managing switch. You can manage
switch by SYSLOG, E-MAIL, and Fault Relay. It helps you to monitor the
switch status on remote site. When events occurred, the warning message
will send to your appointed server, E-MAIL, or relay fault to switch panel.

Fault Alarm
When any selected fault event is happened, the Fault LED in switch panel
will light up and the electric relay will signal at the same time.

Fault Alarm interface

100
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description

Power Failure Mark the blank of PWR 1 or PWR 2 to monitor.

Port Link Mark the blank of port 1 to port 8 to monitor.


Down/Broken

Apply Click “Apply” to set the configurations.

Help Show help file.

101
Open-Vision User’s Manual

System Warning
System alarm support two warning mode: 1. SYSLOG. 2. E-MAIL. You can
monitor switch through selected system events.
System Warning – SYSLOG Setting
The SYSLOG is a protocol to transmit event notification messages across
networks. Please refer to RFC 3164 - The BSD SYSLOG Protocol

System Warning – SYSLOG Setting interface

102
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description

„ Disable: disable SYSLOG.


„ Client Only: log to local system.
„ Server Only: log to a remote SYSLOG
SYSLOG Mode
server.
„ Both: log to both of local and remote server.

SYSLOG Server IP The remote SYSLOG Server IP address.


Address

Apply Click “Apply” to set the configurations.

Help Show help file.

103
Open-Vision User’s Manual

System Warning – SMTP Setting.


The SMTP is Short for Simple Mail Transfer Protocol. It is a protocol for
e-mail transmission across the Internet. Please refer to RFC 821 - Simple
Mail Transfer Protocol.

System Warning – SMTP Setting interface

104
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description
Enable/Disable transmission system warning events by
E-mail Alarm
e-mail.
Sender E-mail
The SMTP server IP address
Address
Mail Subject The Subject of the mail

„ Username: the authentication username.


„ Password: the authentication password.
Authentication „ Confirm Password: re-enter password.

Recipient E-mail The recipient's E-mail address. It supports 6 recipients


Address for a mail.

Apply Click “Apply” to set the configurations.

Help Show help file.

105
Open-Vision User’s Manual

System Warning – Event Selection


SYSLOG and SMTP are the two warning methods that supported by the
system. Check the corresponding box to enable system event warning
method you wish to choose. Please note that the checkbox can not be
checked when SYSLOG or SMTP is disabled.

System Warning – Event Selection interface

106
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description
System Event
System Cold Start Alert when system restart
Power Status Alert when a power up or down
SNMP
Authentication Alert when SNMP authentication failure.
Failure
O-Ring Topology
Alert when O-Ring topology changes.
Change
„ Disable
„ Link Up
Port Event „ Link Down
„ Link Up & Link Down

Apply Click “Apply” to set the configurations.

Help Show help file.

107
Open-Vision User’s Manual

6.11 Monitor and Diag


MAC Address Table
Refer to IEEE 802.1 D Sections 7.9. The MAC Address Table, that is
Filtering Database, supports queries by the Forwarding Process, as to whether
a frame received by a given port with a given destination MAC address is to be
forwarded through a given potential transmission port.

MAC Address Table interface

108
Open-Vision User’s Manual

The following table describes the labels in this screen.

Label Description

Show all MAC addresses mapping to a selected port


Port NO. :
in table.

Clear MAC Table Clear all MAC addresses in table

Help Show help file.

Port Statistics
Port statistics show several statistics counters for all ports

Port Statistics interface

109
Open-Vision User’s Manual

The following table describes the labels in this screen.


Label Description
Type Show port speed and media type.
Link Show port link status.

State Show ports enable or disable.

TX GOOD Packet The number of good packets sent by this port.

TX Bad Packet The number of bad packets sent by this port.

RX GOOD Packet The number of good packets received by this port.

RX Bad Packet The number of bad packets received by this port.

TX Abort Packet The number of packets aborted by this port.

Packet Collision The number of times a collision detected by this port.

Clear Clear all counters.

Help Show help file.

Port Monitoring
Port monitoring supports TX (egress) only, RX (ingress) only, and TX/RX
monitoring. TX monitoring sends any data that egress out checked TX
source ports to a selected TX destination port as well. RX monitoring sends
any data that ingress in checked RX source ports out to a selected RX
destination port as well as sending the frame where it normally would have
gone. Note that keep all source ports unchecked in order to disable port
monitoring.

110
Open-Vision User’s Manual

Port monitoring interface

The following table describes the labels in this screen.


Label Description
The port will receive a copied frame from source port
Destination Port
for monitoring purpose.
The port will be monitored. Mark the blank of TX or
Source Port
RX to be monitored.
TX The frames come into switch port.
RX The frames receive by switch port.

Apply Click “Apply” to set the configurations.

Clear Clear all marked blank.(disable the function)

Help Show help file.

111
Open-Vision User’s Manual

System Event Log


If system log client is enabled, the system event logs will show in this table.

System event log interface

The following table describes the labels in this screen.


Label Description
Page Select LOG page.
Reload To get the newest event logs and refresh this page.
Clear Clear log.

Help Show help file.

112
Open-Vision User’s Manual

6.12 LLDP
LLDP (Link Layer Discovery Protocol) function allows the switch to advertise its
information to other nodes on the network and store the information it
discovers

LLDP Configuration Interface

6.13 Save Configuration


If any configuration changed, “Save Configuration” should be clicked to
save current configuration data to the permanent flash memory. Otherwise,
the current configuration will be lost when power off or system reset.

113
Open-Vision User’s Manual

System Configuration interface

The following table describes the labels in this screen.


Label Description
Save Save all configurations.
Help Show help file.

114
Open-Vision User’s Manual

Switch Status Interface


7.1 The GUI for users to get switch status
Users are able to get switches information by the simple interface.

Icon Description

Show the IP and MAC Address of the switch.

Show the port link status of the switch.

Show switch status:

Online/Offline: Show switches status.

Query Failure: When Open-Vision can not query. It is


the problem of PC. It maybe the wrong configuration
or etc.

IP different: When IP changed, the light will from


green change to red to inform user the IP had been
changed.

Device Fault: When fault alarm event occurred, the


light will from green change to red to inform user.

115
Open-Vision User’s Manual

Open-Vision can notice user that SYSLOG event

status. User can know unread event and click


to show the detail event log window.

116
Open-Vision User’s Manual

Switch Configuration Interface


8.1 The relationship of function interface and

the configuration interfaces


When user selects the function to configure, the related parameters will be
displayed on configuration interface for user to set detail configurations. An
example as below:

117
Open-Vision User’s Manual

Topology View
9.1 About the Topology View
Topology View is a useful and powerful network topology utility. It is able to
display the network topology automatically. The network administrators are
able to monitor the network devices and links status via Topology View
immediately.

9.2 Start to use Topology View

Select [Devices Topology] and click [Devices Topology]

118
Open-Vision User’s Manual

9.3 Topology View Main Interface


First use, needs user's input devices IP range , after pushes "Star", topology
view begins scan devices , scan finishes, push "finish", finishes topology to
plan.

1、Click Star Scan device

2、Scan succeeds, click finish, finishes planning

119
Open-Vision User’s Manual

3、Auto Finish topology plan

Topology interface can be divided into 6 parts, it is " System Bar ", " Function
Bar ", " Device Tree ", " Topology Area " respectively, " System Log Area ",
Group Table

120
Open-Vision User’s Manual

9.4 System Bar


File
Select File to show the File menu.

Label Hotkey Description

Ctrl + N Reopen a new Topology View program.

Load the configuration that you saved


Ctrl + O
before.
Loaded different Topology save config,
Ctrl + I
amalgamate in the same Group Table

Ctrl + C Close Topology Group Table

Save the current configuration as a


Ctrl + S
*.GML file.
Save the ALL configuration as a *.GML
Ctrl + L
file.
Load OID Config File(Need to set up
N/A
OIDMandialog first)

121
Open-Vision User’s Manual

SAVE OID Config File(Need to set up


N/A
OIDMandialog first)
Save topology view utility “system
config” configuration, If does not save,
N/A
after restarting the software, " system
config" will turn into the default value.

Ctrl + E Terminate Topology View program

Task
Select Task to show Task menu.

Label Hotkey Description


Discover the switches on the same
subnet. Topology View will display all
discovered switches on the device list, and
display the whole network topology
Ctrl + D
automatically on the topology area.
Topology View discovers switches depend
on LLDP and SNMP (Read community is
public).

122
Open-Vision User’s Manual

Label Hotkey Description


Auto Polling:Enable or disable Auto Polling
function.

Ping Check:Use ping to auto polling.

Contact Check:Use Snmp packet to auto


polling.

Auto Polling Time:The auto polling timer


configuration.

Device(s)/Interval:Topology view system each


time enforce auto polling quantity , set zero as,
each time polling all devices.

Ping Waiting Time:When use ping to auto


polling, this parameter is the timer that wait for
ICMP reply packets.
N/A

Trap Agent Alive:Enable trap agent can


receive SNMP trap.

SNMP Community:Configure SNMP’s


Community and Version. Topology View will
use these parameters to discover the devices in
the same network.

Explorer Path:Specify the Internet Explorer


path in the OS.

Report Manage:Auto save system log area info


to excel file.

123
Open-Vision User’s Manual

Entry : System log reaches the designated


quantity, auto save to Excel file.

Daily:Reach designated o'clock, auto save


to Excel file.

124
Open-Vision User’s Manual

Label Hotkey Description


ToolTip Option : Enable or disable to display
the switches certain information.
N/A
View Option: Setting path size & font size and
Icon color..

Label Hotkey Description


This function, can let us oneself define
device Icon. Only need to put the designated
picture to c: \Program Files\Open-Vision
\rec\device, Appoint the corresponding file
name, can finish the ICON configuration.

N/A Select OID : Select to want oneself to define


Icon device the OID.

OID: Input want oneself to define Icon device


the OID.

125
Open-Vision User’s Manual

Linkup Icon : Appoint corresponding


"Linkup Icon" icon name.

Linkdown Icon : Appoint corresponding


"Linkdown Icon" icon name.

Trap Icon : Appoint corresponding "Trap


Icon" icon name.

Locate Icon : Appoint corresponding


"Locate Icon" icon name.

126
Open-Vision User’s Manual

View
Can define the project that Function Bar reveals by oneself.

Layout
Topology view has provide three Layout algorithms,He can help users, faster
automatic planning topology.
(About the information of various Layout, can consult http://jung.sourceforge.net/site/apidocs/index.html)

127
Open-Vision User’s Manual

Management
Select Management to show Management menu.

Label Hotkey Description


Input IP addresses of two target devices, will
N/A show the link information between these two
hosts.

128
Open-Vision User’s Manual

Label Hotkey Description


Manage topology group.
Group Name : Define group name
New : Add new group.
N/A
Delete : Delete group.
Rename : Group Rename.
Group : show select group device ip list

129
Open-Vision User’s Manual

Group setting method

1、 Add new group

Input Group name, then click “ ”

We can find that here " Group Name" Project among,increase oring group

2、 Appoint device

Select group project to defaultGroup and oring group

130
Open-Vision User’s Manual

Utilize and to move device ip to designated group

131
Open-Vision User’s Manual

Label Hotkey Description

N/A User can clear Topology Area status

N/A User can clear trap log area

N/A Save system log area info to Excel file.

User can define Group table the name by


N/A
oneself.

Help
Select Help to show Help menu.

Label Hotkey Description


Show the version information of Topology
About N/A
View.

132
Open-Vision User’s Manual

9.5 Function Bar

Icon Description

The same with task “Discovery”.

Refresh the host

Zoom in the topology.

Zoom out the topology.

Auto Layout

Centralize

User can clear Topology Area status

User can oneself define group name

Transforming:Move all switches at the same


time.

Picking:Pick one switch to move.

Editing : When Topology Area into editing


mode, users are able to add or delete
switches and links.

133
Open-Vision User’s Manual

Find the specific host in the topology.

Show Designated Device info

9.6 Device Tree


After execute Discovery, Topology View will list the discovered devices on the
Device Tree.

Select certain note, and right-click the mouse, will show the menu.

134
Open-Vision User’s Manual

Task Hotkey Description

Open Web N/A Open Switch Web Page

Log Event N/A Open Switch Log Event Table.


Show Device Information

1、Port Neighbor List

Device
N/A Neighbor IP:Show Neighbor Device IP.
Information
Name:Show Switch model name.
Description:Show device Description.
ChassisID:Show device MAC.
2、Device Detail

135
Open-Vision User’s Manual

Device Annotation : Can accord with user's


demand, increase notes

Topology
N/A
Management
Can reveal the information of the adjoint devices.

Path
N/A
management

Find It N/A Look for the position that appoints the device.
Location
N/A “Enable” or ”Disable” location alert.
Alert

136
Open-Vision User’s Manual

9.7 Group Tree


After execute Discovery, Topology View will list the discovered devices on the
Group Tree.

Select certain note, and right-click the mouse, will show the menu.

137
Open-Vision User’s Manual

Task Hotkey Description

Manage Group N/A Same Page 128,Manage Group function.

Show this Show this group to new group table.( Must define
N/A
Group app group first)
Select Group
N/A Choose all devices in this group.
Devices

Add Group N/A Increase a new group.

Delete Group N/A Delete one group

Rename Group N/A Change group name.

Show / Hide N/A Regard group as the unit, show or hide devices

138
Open-Vision User’s Manual

9.8 Topology Area


After execute “Discovery”, Topology View will display the network topology
automatically on the topology area.

Note:

Topology View is able to discover the device when set SNMP Read Community to ‘public’.

Topology View is able to show the connection of link through LLDP Packets from device.

139
Open-Vision User’s Manual

When choose “Transforming”, users are able to move all devices on the
topology area at the same time.

When choose “Picking”, users are able to move the specific switch or
right-click the mouse to show the menu.

140
Open-Vision User’s Manual

Task Hotkey Description

Open Web N/A Open Switch Web Page

Log Event N/A Open Switch Log Event Table.

Show Device Information


1、Port Neighbor List

Neighbor IP:Show Neighbor Device IP.


Device
N/A Name:Show Switch model name.
Information
Description:Show device Description.
ChassisID:Show device MAC.
2、Device Detail

141
Open-Vision User’s Manual

Device Annotation:Can accord with user's demand, increase


notes

Can reveal the information of the adjoint devices.

Path
N/A
Management

Topology
N/A
Management
Device
N/A Can accord with user's demand, increase switch notes.
Annotation
Start " Network Flow" Function, the user can control Network
Flow which appoints port.

Network
N/A
Flow

Enable
Location N/A “Enable” or ”Disable” location alert.
alert
Change The user can choose designated device, changes him group
N/A
Group disposes

142
Open-Vision User’s Manual

When the cursor points to the link you want to select. Right click the mouse to
show the menu.

Task Hotkey Description


Can reveal the information of the adjoint devices.

Path
N/A
Management

Link
N/A Can accord with user's demand, increase Link notes.
Annotation

143
Open-Vision User’s Manual

9.9 System Log Area


Reveal port, power, topology change.various states. And can save for excel file.
Help users carry on the mistake to manage.

144
Open-Vision User’s Manual

Host Monitor
"Host monitor" It is a Device control software, He can be via group or device
IP range control any contains IP a device, Do not restrict the brand or device
kind, enable users to control all device on the network, reach omni-directional
control.

10.1 System Bar


File
Select File to show the File menu.

145
Open-Vision User’s Manual

Label Hotkey Description

Ctrl + N Stat new host monitor work

Load the configuration that you saved


Ctrl + O
before.
Save the current configuration as a
Ctrl + S
*.mnt file.

Ctrl + E Terminate Host monitor program

View
Show / Hide Various system bar

Label Hotkey Description


ToolBar N/A Show / Hide ToolBar
Agent Interval N/A Show / Hide Agent Interval
Agent SNMP N/A Show / Hide Agent SNMP
Find N/A Show / Hide Find

About
Show Host monitor version.

146
Open-Vision User’s Manual

10.2 Function Bar

Label Hotkey Description

Ctrl + N Stat new host monitor work

Load the configuration that you saved


Ctrl + O
before.
Save the current configuration as a
Ctrl + S
*.mnt file.

N/A Increase a host monitor job.

N/A Delete a host monitor job.

N/A Start or Stop monitor

Interval N/A Monitor devices Interval


" Timeout" : " Host monitor" Check the
number of times of devices, if exceed,
Timeout N/A
does not connect to the devices yet,
judge for link down
Community N/A SNMP Community String
Ver N/A SNMP Agent Version
Find N/A Look for designated device

147
Open-Vision User’s Manual

10.3 Devices Tree


Show host monitor group.Tree.

Label Hotkey Description


Add Increase a host monitor job.

Add Host:
1、config monitor Rang

N/A

Host:add single device


Prefix:IP Prefix
Start:IP Rang start value
End:IP Rang end value.

:Confirm buttons

148
Open-Vision User’s Manual

2、confirm rang and apply

3、Start monitor

Add Group:
1、config monitor group Rang(single or a lot of)

Group:add single or a lot of device


Prefix:IP Prefix

149
Open-Vision User’s Manual

Start:IP Rang start value


End:IP Rang end value.

:Confirm buttons

2、confirm rang and apply

3、Start monitor

Delete N/A Delete a host monitor job.


Edit Edit group info.

N/A

Name:Define group name


Description:Define Description

150
Open-Vision User’s Manual

10.4 Monitor Area


User can by " HOST Monitor" Informnation intact control in network state of
apparatus.

MIB Brower
It is a Standard SNMP MIB Brower, the user does not need to buy MIB Brower
in addition, OPEN VISION 2.0 offers intact MIB Brower, users can to utilize
SNMP MIB File, manage the apparatus of different brands at the same
time,reach omni-directional management.

151
Open-Vision User’s Manual

TroubleShooting
11.1 Why Topology View can not run in our
computer?
Please make sure your computer has installed JRE, if not, please install Java
Runtime Environment (JRE) 6 Update 3 from SUN’s website.
http://java.sun.com/javase/downloads/index.jsp

11.2 License key warning message


When implement Open-Vision, the computer pop-up the warning message as
below. It’s meaning that the computer didn’t insert the USB license key.
Please insert license key to enter license mode and then press ok or press
cancel to limit the operations to 10 devices.

11.3 SYSLOG warning message


When implement Open-Vision, the computer pop-up the warning message as
below. You can check is there any third party System Log Server (ex:tftpd or
ORing’s DS-Tool) running on the computer. If you do not care about the
system log function, press 「Ignore」to continue.

152
Open-Vision User’s Manual

11.4 Why Topology View can not receive SNMP


trap?
When open Topology VIEW, if the computer pop-up the warning message as
below. You can check is there any running third party SNMP software (ex:
MG-Soft or SNMPc) on the computer. Please stop these applications,
because these applications will occupy SNMP port.

153