MFX - 44
MFX - 44
MFX_4 2
MFX_4
CPMPACT PRO
MFX_4 3
MFX_4
Touch /S
MFX_4 Terminal Pro Touch /S IP65
The MFX_4 Terminal Pro Touch IP65 is the enhanced version of the human‐machine
interface (HMI) from the MFX_4 family for use in industrial environments where you
don’t need a Foil Keyboard. The terminal is equipped with a touch screen and
enables communication with the MFX_4 Controller, with other suitable system
participants or with connected host systems such as SCADA or TAS systems.
MFX_4 4
MFX_4
Touch /L
MFX_4 Terminal Pro Touch /L IP65
The MFX_4 Terminal Pro Touch IP65 is the enhanced version of the Terminal Pro
Touch /S. Additionally it is equipped with an integrated Foil Keyboard and RFID
Reader. The terminal enables communication with the MFX_4 Controller, with other
suitable system participants or with connected host systems such as SCADA or TAS
systems.
MFX_4 5
MFX_4
Touch IP20
MFX_4 Terminal Pro Touch PANEL IP20
The MFX_4 Terminal Pro Touch PANEL IP20 offers the same functionality as the
Terminal Pro Touch /S version. As main application this device is foreseen to be
installed as HMI for control rooms, where it can be easily integrated to control panels
and/or control cabinets.
MFX_4 6
MFX_4 RFID Reader / Access Control
The MFX_4 RFID (Radio Frequency
Identification) is the external explosion‐
proof version of the multi‐protocol card
reader for contactless identification and
access control based on RFID cards in
13.56 MHz technology. The device
supports a wide range of card types and
transmits the data it has to read to the
connected device via a bus‐enabled
RS485 interface.
© M+F TECHNOLOGIES GMBH 2020 7
Applications
Railcar Loading
Refueller
© M+F TECHNOLOGIES GMBH 2020 8
Typical System for Truck Loading
© M+F TECHNOLOGIES GMBH 2020 9
Typical System Configuration
TAS 0 4 8 0 4 8 12 0 4 8 12 0 4
DC O UTPUT
AC/DC OUT
DC INPUTS
AC INPUT
1 5 9 1 5 9 13 1 5 9 13 1 5
PLC
2 6 10 2 6 10 14 2 6 10 14 2 6
3 7 11 3 7 11 15 3 7 11 15 3 7
230 VAC 24 VDC SINK / SOURCE 24 VDC SOURCE RELAY
Allen-Bradley MicroLogix
QUAL ITY DC INPUTS
1500
0 4 8 12 0 0 0 0
1 5 9 13
2 6 10 14 1 1 1
3 7 11 15
2 2 2 1
24 V SINK / SOURCE
3 3 3
DC / RELAY OUT
POWER 4 4 4 2
RUN 0 4 8
1 5 9 5 5 5
FAULT
2 6 10
FORCE 3 7 11
6 6 6 3
BAT.LO 7 7 7
24 V SOURCE
CONN 0
8 8 8 4
DCOMM
9 9 9
10 10 10 5
11 11 11
LSP
28BXB 12 12 6
DC POWER
24V
13 13
14 14 7
15 15
Ethernet
EDI EDI EDI
CAN Bus
CAN Bus
CAN Bus
Terminal Pro Terminal Pro Terminal Pro
10
MFX_Functions
Volume/
Differential Mass
Pressure Pressure Ramp Control
Conversion/
Measure
Alcohol in
Water Script Pipeline
Density Bio Products
Determinati Language Mode
on
MFX_4 11
MFX_4 Data Exchange
MFX_4 12
UPC_2000
UPC UPC UPC
Viewer Viewer
Ethernet
EDI CTRL
CAN Bus
Terminal
Pro
MFX_4 13
UPC_Viewer
MFX_4 14
OPC Server/Client
TAS PLC OPC
0 4 8 0 4 8 12 0 4 8 12 0 4
DC O UTPUT
AC/DC O UT
DC INPUTS
Server
AC INPUT
1 5 9 1 5 9 13 1 5 9 13 1 5
2 6 10 2 6 10 14 2 6 10 14 2 6
3 7 11 3 7 11 15 3 7 11 15 3 7
230 VAC 24 VDC SINK / SOURCE 24 VDC SOURCE RELAY
Allen-Bradley MicroLogix
QUAL ITY DC INPUTS
1500
0 4 8 12 0 0 0 0
1 5 9 13
2 6 10 14 1 1 1
3 7 11 15
2 2 2 1
24 V SINK / SOURCE
3 3 3
DC / RELAY OUT
POWER 4 4 4 2
RUN 0 4 8
FAULT 1 5 9 5 5 5
2 6 10
FORCE 3 7 11
6 6 6 3
BAT.LO 7 7 7
24 V SOURCE
CONN 0
8 8 8 4
DCOMM
9 9 9
10 10 10 5
11 11 11
LSP
28BXB 12 12 6
DC POWER
24V
13 13
14 14 7
15 15
Ethernet
EDI CTRL
CAN Bus
Terminal
Pro
MFX_4 15
Modbus TCP
TAS PLC UPC
0 4 8 0 4 8 12 0 4 8 12 0 4
DC O UTPUT
AC/DC O UT
DC INPUTS
AC INPUT
1 5 9 1 5 9 13 1 5 9 13 1 5
2 6 10 2 6 10 14 2 6 10 14 2 6
3 7 11 3 7 11 15 3 7 11 15 3 7
230 VAC 24 VDC SINK / SOURCE 24 VDC SOURCE RELAY
Allen-Bradley MicroLogix
QUAL ITY DC INPUTS
1500
0 4 8 12 0 0 0 0
1 5 9 13
2 6 10 14 1 1 1
3 7 11 15
2 2 2 1
24 V SINK / SOURCE
3 3 3
DC / RELAY OUT
POWER 4 4 4 2
RUN 0 4 8
FAULT 1 5 9 5 5 5
2 6 10
FORCE 3 7 11
6 6 6 3
BAT.LO 7 7 7
24 V SOURCE
CONN 0
8 8 8 4
DCOMM
9 9 9
10 10 10 5
11 11 11
LSP
28BXB 12 12 6
DC POWER
24V
13 13
14 14 7
15 15
Ethernet / MODBUS TCP
EDI CTRL
CAN Bus
Terminal
Pro
MFX_4 16
Modbus RTU (RS 485)
TAS UPC PLC
0 4 8 0 4 8 12 0 4 8 12 0 4
DC O UTPUT
AC/DC OUT
DC INPUTS
AC INPUT
1 5 9 1 5 9 13 1 5 9 13 1 5
2 6 10 2 6 10 14 2 6 10 14 2 6
3 7 11 3 7 11 15 3 7 11 15 3 7
230 VAC 24 VDC SINK / SOURCE 24 VDC SOURCE RELAY
Allen-Bradley MicroLogix
QUAL ITY DC INPUTS
1500
0 4 8 12 0 0 0 0
1 5 9 13
2 6 10 14 1 1 1
3 7 11 15
2 2 2 1
24 V SINK / SOURCE
3 3 3
DC / RELAY OUT
POWER 4 4 4 2
RUN 0 4 8
1 5 9 5 5 5
FAULT
2 6 10
FORCE 3 7 11
6 6 6 3
BAT.LO 7 7 7
24 V SOURCE
CONN 0
8 8 8 4
DCOMM
9 9 9
10 10 10 5
11 11 11
LSP
28BXB 12 12 6
DC POWER
24V
13 13
14 14 7
15 15
Ethernet / MODBUS TCP
EDI CTRL
CAN Bus
Modbus
RTU
Terminal
Pro
MFX_4 17
MFX_90 Emulation MCO_1
TAS PLC UPC
0 4 8 0 4 8 12 0 4 8 12 0 4
DC O UTPUT
AC/DC O UT
DC INPUTS
AC INPUT
1 5 9 1 5 9 13 1 5 9 13 1 5
2 6 10 2 6 10 14 2 6 10 14 2 6
3 7 11 3 7 11 15 3 7 11 15 3 7
230 VAC 24 VDC SINK / SOURCE 24 VDC SOURCE RELAY
Allen-Bradley MicroLogix
QUAL ITY DC INPUTS
1500
0 4 8 12 0 0 0 0
1 5 9 13
2 6 10 14 1 1 1
3 7 11 15
2 2 2 1
24 V SINK / SOURCE
3 3 3
DC / RELAY OUT
POWER 4 4 4 2
RUN 0 4 8
FAULT 1 5 9 5 5 5
2 6 10
FORCE 3 7 11
6 6 6 3
BAT.LO 7 7 7
24 V SOURCE
CONN 0
8 8 8 4
DCOMM
9 9 9
10 10 10 5
11 11 11
LSP
28BXB 12 12 6
DC POWER
24V
13 13
14 14 7
15 15
Ethernet MODBUS TCP
EDI CTRL
MCO_1 CAN Bus
RS 232
Terminal
Pro
MFX_4 18
MFX_4 Explorer
MFX_4 19
MFX_4 Explorer Graph
MFX_4 20
MFX_4 Explorer Logger
MFX_4 21
MFX_4
Thank you for your attention ☺
MFX_4 22