Torque Sensor Position Sensor Battery S1 S2 S3 S4: Tap Nominal 50/60Hz W 220/230 X 380/400 Y 400,415/420 Z 440/460 Type 1
Torque Sensor Position Sensor Battery S1 S2 S3 S4: Tap Nominal 50/60Hz W 220/230 X 380/400 Y 400,415/420 Z 440/460 Type 1
Torque Sensor Position Sensor Battery S1 S2 S3 S4: Tap Nominal 50/60Hz W 220/230 X 380/400 Y 400,415/420 Z 440/460 Type 1
CIRCUIT DRAWN WITH POWER SUPPLY OFF FOR TYPICAL REMOTE CONTROL
M 2
2 DETAILS, SEE DOCUMENT
3
3 V
4
1
3
PHASE
RWS103
SUPPLY
U
3 1 TR AN S F OR ME R TAP P IN G OP TION S
6
5 T ap Nominal 50/60Hz
U V W E TYP E 1
FS1
W 220/230
X 380/400
C1 C2 Y 400,415/420
U W X Y Z
Z 440/460
F US E F S 1= 250mA A NTI-S UR G E
SK2 TYP E 2
0VAC 1
TRANSISTOR SWITCHING FOR 4 120VAC W 346/380
PS1 NOMINAL SUPPLY X 480/500
24VDC CONTACTORS (IQ10-35) 120VAC 4
RELAYS ONLY FITTED WHEN
5 (OUTPUT)
0VDC
Y 240/240
120VAC CONTACTOR IS FITTED 3 Z 550/575
FOR IQ40,70,90,91 & 95 24VDC 6 F US E F S 1= 250mA A NTI-S UR G E
_
+
TYP E 3
SK14
X 660/660-690
0VDC 1
Y 690/-
24VDC 2 F US E F S 1= 150mA A NTI-S UR G E
SK13
26 WAY
REFER TO SHEET 2 FOR NOTES
& OPTION PCB'S IF FITTED
OPEN REMOTE
LOCAL
OPEN INTERLOCK 13 37
CLOSE INTERLOCK 14 38
COMMON -VE 5 31
SK1 SK2
SLOT A SLOT B
SK1
SLOT C
NO CONNECT 5
CPT
MANUAL/AUTO 6 39
COMMON -VE 24VDC 7 41 50%
COMMON -VE 120VAC 8 45
STOP
CLOSE
LOCAL
REMOTE HAND
OPEN REMOTE
ISOLATOR
DC
STATION
DC 18 WAY
SK2
FOR MANUAL/AUTO CONNECTIONS AND
DETAILS OF FOLOMATIC/CPT FUNCTIONS RHS Bridge Board
REFER TO ROTORK PUBLICATION PUB002-041
SK1
1 2 3 4 5
OPTION CARD
CAN SHIELD
SK3 3
CAN L
4 40 RHS CABLE IS CUSTOMER SUPPLIED, FOR
0V (RHS) SPECIFICATION SEE PUB002-059,
5 21 MAXIMUM LENGTH OF CABLE TO BE 100m.
47
Actuator RHS
46
SLOT C SK1 E
Terminal Terminal Function
SLOT C SK1 Bung No. Block No.
A
EXTRA CHANGE OVER CONTACTS
2 14 20 1 +24V (RHS)
FOR OTHER SETTINGS SEE PUB002-038
S5 3 B
MAKE AT FULLY SHUT 16
21 2 0V (RHS)
DEFAULT SETTINGS SHOWN
1
C 32 3 CAN H
5 17
MAKE AT FULLY OPEN S6 6 D 40 4 CAN L
19
4
47 5 SHIELD
8 E
MAKE ON TORQUE
15
F
TRIP S7 9 24
7
11 G 30
MAKE WHEN REMOTE
SELECTED S8 12 H 18
10
NOTES
1.FUSES:
-PS1 is a self-resetting fuse. 3.INDICATION:
-Refer to publication PUB002-039 for approved fuses FS1 and FS2. -For typical position, status and alarm indication see PUB002-041.
-Actuator rated voltage specified on nameplate. Voltage tolerance +/-10%, -“S” contacts are user configurable and are shown in their default
applies for rated torque performance; duty cycle is not guaranteed. setting.
2.REMOTE CONTROL: -Refer to PUB002-040 for functions and configuration instructions.
-For typical remote control circuits refer to: -Monitor Relay indicates actuator availability for remote control (shown
-RWS indicated or PUB002-041. “unavailable”). It can be configured to exclude local/remote selection.
-For DC and AC control, connect –ve/0V to terminal 36. -Refer to PUB002-040 for monitored functions and configuration
-(For negative switch / positive common, refer to RWS indicated). instructions.
-Control signal threshold voltages: -Voltage applied to indication contacts must not exceed 150Vac
-DC: “on” ≥16Vdc / “off” ≤8Vdc, max 60Vdc. -Individual Switch current must not exceed 3.5A inductive, 5A resistive
-AC: “on” ≥60Vac / “off” ≤40Vac, max 120Vac. and no more than 8A in total for all 4 contacts.
-Control signal duration to be 300ms minimum.
-Maximum current drawn from remote control signals is: 4.BATTERY:
-8mA at 24Vdc or 12mA at 120Vac. -Battery maintains local and remote “S” contact indication only.
-Supply provided on terminals 4 & 5: -Refer to installation manual for approved replacement battery types.
-Intended for remote control. Circuit Diagram Number Issue Sheet
-Max external load 5W at 24Vdc / 5VA at 120Vac No
113B0016 1 2
See Sheet 1 for all Revision details/information of 2
IQ3