0% found this document useful (0 votes)
96 views12 pages

4F Design-2

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 12

ONE WAY SLAB DESIGN

S2 S2 S2

S1 S1 S1 S1

S1

S2 S2 S2

NSCP Coeffiecients for continuous beams and slabs


L1 L2 L3

wL1^2/14 wL1^2/16 wL1^2/14

wL1^2/16 wL1^2/10 wL1^2/10 wL1^2/24

Beam Width= 300 mm 6


wu = 7.8568 kPa
hmin = 115 mm (Table 2.1) 3

6
SLAB-1 3
f'c = 21 MPa
fy = 276 MPa
Rebar dia. = 12 mm
Slab T = 115 mm
cc = 20 mm
Ab = 113.10 mm2
rmin = 0.00507
rmax = 0.01883
f = 0.9

SLAB-1 12 mm@ 250 mm O.C. 12 mm@ 490 mm O.C.


Discontinuos Continuos
Mid
edge edge
Mu - 4.42 7.07
b - 1000 1000
d - 89 89
Ru - 0.6199 0.9919
r - 0.00229 0.00370
Use r - 0.00507 0.00507 3m
As - 451.45 451.45
N - 4 4
Main Bars
s - 250 250
Use s - 250 250
Temperature Bars
As - 230 230
s - 490 490
SLAB DESIGN BY DIRECT DESIGN METHOD (Short Span)
DL = 1.3 kPa
LL = 1.9 kPa
Use h = 115 mm
Floor weight= gconc x slab T
Floor weight= 2.71 kPa
Total DL = 4.01 kPa
wu = 1.2 DL + 1.6 LL
wu = 7.8568 kPa

Using 12 mm diameter bars


d = slab T-.5*bar dia.-cc
cc = 20 mm
d = 89 mm

Check the depth for shear:


* Beams with a1L2/L1>=1 shall be proportioned to resist shear caused by factored loads
on tributary areas bounded by 45 degress lines drawn from the corners of the panels
and the center-lines of the adjacent panels parallel to the long sides

a1L2/L1 2.90 >1 check w.b. shear


x = 1.836 m
b = 1m
Vu = wu * Ashaded
Vu = 14.43 kN
Vc = 1/6*f'c^.5*b*d x
Vc = 67.97 kN 1 L1= 6m
f = 0.85 d m strip
fVc = 57.78 kN
fVc > Vu O.K.

L2= 4.2 m
c.s. for wide beam shear

Moment along the short span:


(Note: This is an interior span)
Mo = (wuL2)*Ln^2/8
L1= Length of span in direction that moments are being determined
measured center to center of supports
Ln= Length of clear span in direction that moments are being determined
L2= Length of span transverse to L1, measured center to center of supports
L1= 4.2
Ln= 3.85 m L1= 4.2
L2= 6m
Mo = 87.34 kN-m
Negative factored moment= 0.65 x 87.34 Ln
Negative factored moment= -56.77 kN-m L2= 6
Positive factored moment= 0.35 x 87.34
Positive factored moment= 30.57 kN-m
Distributing these moment to beam and column strips:(Table 10.4)
L2/L1 = 1.42857143
a1 = ac = 3.46
a1(L2/L1) = 4.94 (See table 10.4) ===>Interpolated values
From Table 10.4
% of Interior negative moment= 69 % Table 10.4
Interior Negative Moment= -39.17 kN-m ===>(Column Strip)
According to Section 5.13.6.5
85% will be resisted by beam = -33.29736 kN-m
15% will be resisted by slab = -5.876005 kN-m
The remaining is alloted to middle strip = -17.60 kN-m ===>(Middle Strip)
(Negative Factored Moment-Interior Negative Moment)
% of positive moment= 69 % Table 10.7
Positive Moment= 21.09 kN-m ===>(Column Strip)
According to Section 5.13.6.5
85% will be resisted by beam = 17.93 kN-m
15% will be resisted by slab = 3.16 kN-m
The remaining is alloted to middle strip = 9.48 kN-m ===>(Middle Strip)
(Negative Factored Moment-Interior Negative Moment)
Moment along the short span (along edge beam): L1= 5
L2 = 3.175 m
Ln = 3.85 m
Mo = (wuL2)*Ln^2/8
Mo = 46.22 kN-m
Negative factored moment= 0.65 x 46.22
Negative factored moment= -30.04 kN-m
Positive factored moment= 0.35 x 46.22
Positive factored moment= 16.18 kN-m
For this case, Table 10.5 will be used for distribution of negative moments
bt = EcbC
2EcsIs 350
Ecb=Ecs=Ec 150
C = ∑ (1-0.63*x/y)*x^3*y/3 500
Cbeam = 3994520833
Cslab = 287437500 350
C = 4281958333 mm^4 x= 350 x= 150
Is = 843750000 mm^4 y= 500 y= 350
bt = 2.537
L2/L1 = 1.42857143
a1 = aa (for edge beam)
a1 = 6.05
a1(L2/L1) = 8.64

Table 10.5: By Interpolation


Percentage = 62.1428571 %
Exterior Negative Moment:
Column strip= -18.67 kN-m
Beam= -15.87 kN-m
Slab= -2.80 kN-m ===>(Column Strip)
Middle strip= -11.37 kN-m ===>(Middle Strip)

Positive Moment:
Percentage = 69 %
Column strip= 11.16 kN-m
Beam= 9.49 kN-m
Slab= 1.67 kN-m ===>(Column Strip)
Middle strip= 5.01 kN-m ===>(Middle Strip)

-2.80 5.01 -2.80 Exterior column strip

-11.37 5.01 -11.37

-20.17 9.75 -20.17

-8.80 4.74 -8.80

-2.94 1.58 -2.94


Interior column strip

-2.94 1.58 -2.94


SLAB DESIGN BY DIRECT DESIGN METHOD (Long Span)
DL = 1.3 kPa
LL = 1.9 kPa
Use h = 115 mm
Floor weight= gconc x slab T
Floor weight= 2.71 kPa
Total DL = 4.01 kPa
wu = 1.2 DL + 1.6 LL
wu = 7.8568 kPa

Using 12 mm diameter bars


d = slab T-.5*bar dia.-cc
cc = 20 mm
d = 89 mm

Check the depth for shear:


* Beams with a1L2/L1>=1 shall be proportioned to resist shear caused by factored loads
on tributary areas bounded by 45 degress lines drawn from the corners of the panels
and the center-lines of the adjacent panels parallel to the long sides

a1L2/L1 2.90 >1 check w.b. shear


x = 1.836 m
b = 1m
Vu = wu * Ashaded
Vu = 14.43 kN
Vc = 1/6*f'c^.5*b*d x
Vc = 67.97 kN 1 L1= 6m
f = 0.85 d m strip
fVc = 57.78 kN
fVc > Vu O.K.

L2= 4.2 m
c.s. for wide beam shear

Moment along the short span:


(Note: This is an interior span)
Mo = (wuL2)*Ln^2/8
L1= Length of span in direction that moments are being determined
measured center to center of supports
Ln= Length of clear span in direction that moments are being determined
L2= Length of span transverse to L1, measured center to center of supports
L1= 6
Ln= 5.65 m L2= 4.2
L2= 4.2 m
Mo = 131.67 kN-m
Int. Negative factored moment= 0.7 x 131.7 Ln
Int. Negative factored moment= -92.1722 kN-m L1= 6
Positive factored moment= 0.57 x 131.7
Positive factored moment= 75.05 kN-m
Ext. Negative factored moment= 0.16 x 131.7
Ext. Negative factored moment= -21.0679 kN-m

Distributing these moment to beam and column strips:(Table 10.4)


L2/L1 = 0.70
a1 = ab = 4.15
a1(L2/L1) = 2.90 (See table 10.4) ===>Interpolated values
From Table 10.4
% of Interior negative moment= 84 % (Table 10.4) (interpolate !)
Interior Negative Moment= -77.4 kN-m (Column Strip)
According to Section 5.13.6.5
85% will be resisted by beam = -65.8109 kN-m
15% will be resisted by slab = -11.6137 kN-m ===>(Column Strip)
The remaining is alloted to middle strip = -14.7476 kN-m ===>(Middle Strip)
(Negative Factored Moment-Interior Negative Moment)
% of Interior negative moment= 80 % (Table 10.4)
Exterior Negative Moment= -16.9 kN-m (Column Strip)
According to Section 5.13.6.5
85% will be resisted by beam = -14.3262 kN-m
15% will be resisted by slab = -2.52815 kN-m ===>(Column Strip)
The remaining is alloted to middle strip = -4.2 kN-m ===>(Middle Strip)
(Negative Factored Moment-Interior Negative Moment)
% of positive moment= 84 % (Table 10.7)
Positive Moment= 63 kN-m (Column Strip)
According to Section 5.13.6.5
85% will be resisted by beam = 53.59 kN-m
15% will be resisted by slab = 9.46 kN-m ===>(Column Strip)
The remaining is alloted to middle strip = 12.01 kN-m ===>(Middle Strip)

-1.26 -1.26 -4.2 -1.26 -1.26

4.73 4.73 12.01 4.73 4.73

-5.81 -5.81 -14.75 -5.81 -5.81


SLAB DESIGN BY DIRECT DESIGN METHOD

f'c = 21 MPa
fy = 276 MPa
Rebar dia. = 12 mm
Slab T = 115 mm
cc = 20 mm
Ab = 113.10 mm2
rmin = 0.00507
rmax = 0.01883
f = 0.9

Column Strip-Left&Right Side Middle Strip


Long Direction Long Direction
Discontinuos Continuos Discontinuos Continuos
Mid Mid
edge edge edge edge
Mu 1.26 4.73 5.81 Mu 4.21 12.01 14.75
b 1000 1000 1000 b 1000 1000 1000
d 89 89 89 d 89 89 89
Ru 0.1773 0.6633 0.8146 Ru 0.5911 1.6845 2.0687
r 0.00065 0.00245 0.00302 r 0.00218 0.00642 0.00799
Use r 0.00507 0.00507 0.00507 Use r 0.00507 0.00642 0.00799
As 451.45 451.45 451.45 As 451.45 571.57 710.99
N 4 4 4 N 4 6 7
s 250 250 250 s 250 190 150
Use s 250 250 250 Use s 250 190 150

Column Strip-Along Edge Beam Column Strip-Along Interior Middle Strip


Short Direction Short Direction Short Direction
Discontinuos Continuos Continuos Discontinuos Continuos Continuos
Mid Mid Mid
edge edge edge edge edge edge
Mu 2.80 5.01 - Mu 2.94 1.58 - Mu 20.17 9.75 -
b 1000 1000 - b 1000 1000 - b 1000 1000 -
d 89 89 - d 89 89 - d 89 89 -
Ru 0.3928 0.7034 - Ru 0.4121 0.2219 - Ru 2.8297 1.3681 -
r 0.00144 0.00260 - r 0.00151 0.00081 - r 0.01123 0.00516 -
Use r 0.00507 0.00507 - Use r 0.00507 0.00507 - Use r 0.01123 0.00516 -
As 451.45 451.45 - As 451.45 451.45 - As 999.22 459.51 -
N 4 4 - N 4 4 - N 9 5 -
s 250 250 - s 250 250 - s 110 240 -
Use s 250 250 - Use s 250 250 - Use s 110 240 -

110 mm O.C.
L/4

L/4

110 mm O.C.

150 mm O.C.

TOP BAR CONFIGURATION-BOTHWAYS

190 mm O.C.
190 mm O.C.

BOTTOM BAR CONFIGURATION-BOTHWAYS


GRADE BEAM DESIGN
GB GB GB GB

GB
GB GB GB GB

GB
GB GB GB GB

GB

GB GB GB GB

GROUND FLOOR

Design Code: NSCP 2010


ACI318-11
Material & Constants:
f'c = 27.6 MPa f = 0.9
fy = 414 MPa
fys = 276 MPa
ccbot = 40 mm Østirrup = 10 mm
b1 = 0.85

At At
Moment
supports midspan
Design
Top Bottom
Moment 197.113 189.738
Øtop 20 20
Øbottom 20 20
nrebar 5 5
b 300 300 H
h 500 500
d 440 440
a 92.40 92.40 300
rmin,1 0.0034 0.0034
rmin,2 0.0136 0.0131 B
rmin 0.0034 0.0034
rmax 0.0214 0.0214
ractual 0.0119 0.0119
D/C Ratio 0.86 0.82
Bottom Top
nrebar 3 3
Shear Design
Vu 283.39 kN at supports at midspan
f 0.75
nlegs 4
fVc 88.42 kN
Av,min,1 0.35 mm2
Av,min,2 0.38 mm2
Av,min 0.35 mm2
smax 220 mm
sreq 887.34 mm
s,rest @ 220 mm
s@2h 150 mm
fVs 254.34 kN 1@50
f(Vc+Vs) 342.76 kN 4 Legs 7 10mmθ @ 150 mm O.C.
fVn 342.76 kN 4 Legs Rest @ 200 mm O.C.
D/C Ratio 0.827
2F BEAM DESIGN

2FB 2FB 2FB 2FB

2FB 2FB
2FB 2FB 2FB
2FB 2FB 2FB 2FB

2FB 2FB
2FB 2FB
2FB 2FB 2FB 2FB
2FB

2FB 2FB 2FB 2FB


2FB 2FB

2FB 2FB 2FB 2FB

2ND FLOOR FRAME

Design Code: NSCP 2010


ACI318-11
Material & Constants:
f'c = 27.6 MPa f = 0.9
fy = 414 MPa
fys = 276 MPa
ccbot = 40 mm Østirrup = 10 mm
b1 = 0.85

At At
Moment
supports midspan
Design
Top Bottom
Moment 172.109 157.753
Øtop 20 20
Øbottom 20 20
nrebar 5 4
b 300 300 H
h 500 500
d 440 440
a 92.40 73.92 300
rmin,1 0.0034 0.0034
rmin,2 0.0118 0.0106 B
rmin 0.0034 0.0034
rmax 0.0214 0.0214
ractual 0.0119 0.0095
D/C Ratio 0.75 0.84
Bottom Top
nrebar 3 2
Shear Design
Vu 271.54 kN at supports at midspan
f 0.75
nlegs 4
fVc 88.42 kN
Av,min,1 0.35 mm2
Av,min,2 0.38 mm2
Av,min 0.35 mm2
smax 220 mm
sreq 887.34 mm
s,rest @ 220 mm
s@2h 150 mm
fVs 254.34 kN 1@50
f(Vc+Vs) 342.76 kN 4 Legs 7 10mmθ @ 150 mm O.C.
fVn 342.76 kN 4 Legs Rest @ 200 mm O.C.
D/C Ratio 0.792
3F - ROOF BEAM DESIGN

Design Code: NSCP 2010


ACI318-11
Material & Constants:
f'c = 27.6 MPa f = 0.9
fy = 414 MPa
fys = 276 MPa
ccbot = 40 mm Østirrup = 10 mm
b1 = 0.85

At At
Moment
supports midspan
Design
Top Bottom
Moment 142.879 108.883
Øtop 20 20
Øbottom 20 20
nrebar 5 4
b 300 300 H
h 500 500
d 440 440
a 92.40 73.92 300
rmin,1 0.0034 0.0034
rmin,2 0.0098 0.0073 B
rmin 0.0034 0.0034
rmax 0.0214 0.0214
ractual 0.0119 0.0095
D/C Ratio 0.62 0.58
Bottom Top
nrebar 3 2
Shear Design
Vu 160.11 kN at supports at midspan
f 0.75
nlegs 2
fVc 88.42 kN
Av,min,1 0.35 mm2
Av,min,2 0.38 mm2
Av,min 0.35 mm2
smax 220 mm
sreq 443.67 mm
s,rest @ 220 mm
s@2h 150 mm
fVs 127.17 kN 1@50
f(Vc+Vs) 215.59 kN 4 Legs 7 10mmθ @ 150 mm O.C.
fVn 215.59 kN 4 Legs Rest @ 200 mm O.C.
D/C Ratio 0.743