You are on page 1/ 3

Display Ethernet Port State(DSP ETHPORT) Page 1 of 3

Display Ethernet Port State(DSP ETHPORT)


Function

Use this command to query the working status and traffic statistics of an Ethernet port. This command is applicable to the FG2a, GOUa, FG2c, and GOUc boards.

Note

1.For the FG2 board, Port No. must not be 1, 2, or 3 if port 0 is a GE port, and Port No. must not be 5, 6, or 7 if port 4 is a GE port.
2.For the GOUa board, Port No. must be 0 or 1. For the GOUc board, Port No. must be 0~3.
3.For the FG2c board, Port No. must be 0~11.

Parameters

Parameter ID Parameter Name Parameter Description


SRN Subrack No. Meaning: Number of the subrack
GUI Value Range: 0~11
Unit: None
Actual Value Range: 0~11
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification : No (No impact on the UE in idle mode)
Impact on Network Performance: None
SN Slot No. Meaning: Indicates the slot number for running this command
GUI Value Range: 0~5, 8~27
Unit: None
Actual Value Range: 0~5, 8~27
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification : Not involved
Impact on Network Performance: None
PN Port No. Meaning: Ethernet port
GUI Value Range: 0~11
Unit: None
Actual Value Range: 0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc)
MML Default Value: None
Recommended Value: None
Parameter Relationship: None
Service Interrupted After Modification : Yes
Impact on Network Performance: None

Example

To query Ethernet port 0 on the GOUc board that is installed in slot 20 in subrack 1, execute the following command:
DSP ETHPORT: SRN=1, SN=20, PN=0;

The result is as follows:


%%DSP ETHPORT: SRN=1, SN=20, PN=0;%%
RETCODE = 0 Execution succeeded.

ETHPORT state
-------------
Slot No. = 20
Port No. = 0
Port type = GE optical port
Port state = Activated
Link Availability Status = Available
IP Address-0 = 0.0.0.0
Net Mask-0 = 0.0.0.0
IP Address-1 = 0.0.0.0
Net Mask-1 = 0.0.0.0
IP Address-2 = 0.0.0.0
Net Mask-2 = 0.0.0.0
IP Address-3 = 0.0.0.0
Net Mask-3 = 0.0.0.0
IP Address-4 = 0.0.0.0
Net Mask-4 = 0.0.0.0
IP Address-5 = 0.0.0.0
Net Mask-5 = 0.0.0.0
MAC address = 00-A3-00-B2-00-C3
State Changed Time = <NULL>
State Changed Cause = <NULL>
In-position information of optic module = In position
Factory information of optic module = SumitomoElectric
Optic module type = GE
Optic module velocity = 1000Mbps
Optic module transmit distance[m] = 10000
Optic wavelength = 1310nm
Optic module transmit mode = Single
Max transmit unit = 1500
Speed = 1000M
Duplex = Full
Auto negotiation = Enable
Loopback = No loopback
Flow control mode = Disable
Backup mode or not = Not backup
Primary flag = Yes
Display Ethernet Port State(DSP ETHPORT) Page 2 of 3

Number of Frames received with VLAN flag = <NULL>


Number of Frames sent with VLAN flag = <NULL>
Rx correct packages = 1403
Tx correct packages = 0
Rx bad frames = 0
Tx bad frames = 0
Number of received Pause frame = 0
Number of sent Pause frame = 0
Number of received Package Bytes = 113459
Number of sent Package Bytes = 0
Number of Bad Uplink TAG packages = 0
Number of Bad Uplink MAC packages = 602
Number of Uplink Success packages = 801
Rx check error packages = 0
Number of Sent OAM Loopback packages = 0
Number of Sent 802.3AH packages = 0
Number of received Unicast packages = 602
Number of received Multicast packages = 154
Number of received broadcast packages = 647
Number of received Jumbo Frames = 0
Number of Success Recieved VLAN Packages = 0
Number of Success Recieved Non-VLAN Packages = 801
Number of Discard VLAN Packages With UNTAG = 0
Number of Discard Non-VLAN Packages With TAG = 0
Number of sent Unicast packages = 0
Number of sent Multicast packages = 0
Number of sent broadcast packages = 0
Number of sent Jumbo frame = 0
Tx optical power[mw] = 0.263700
Rx optical power[mw] = 0.219500
(Number of results = 1)

--- END

Output Description

Domain Name Description


Slot No. Number of the slot
Port No. Number of the Ethernet port
Port type Type of the Ethernet port, value range: FE electrical port, GE electrical port, GE optical port
Port state State of the Ethernet port, value range: Activated, Deactivated
Link Availability Status Link Availablility Status, value range: Available, Unavailable
IP Address-0 The first IP address of the Ethernet port. Each port can be configured with a maximum of six IP addresses
Net Mask-0 Subnet mask of the first IP address of the Ethernet port
IP Address-1 The second IP address of the Ethernet port. Each port can be configured with a maximum of six IP addresses
Net Mask-1 Subnet mask of the second IP address of the Ethernet port
IP Address-2 The third IP address of the Ethernet port. Each port can be configured with a maximum of six IP addresses
Net Mask-2 Subnet mask of the third IP address of the Ethernet port
IP Address-3 The fourth IP address of the Ethernet port. Each port can be configured with a maximum of six IP addresses
Net Mask-3 Subnet mask of the fourth IP address of the Ethernet port
IP Address-4 The fifth IP address of the Ethernet port. Each port can be configured with a maximum of six IP addresses
Net Mask-4 Subnet mask of the fifth IP address of the Ethernet port
IP Address-5 The sixth IP address of the Ethernet port. Each port can be configured with a maximum of six IP addresses
Net Mask-5 Subnet mask of the sixth IP address of the Ethernet port
MAC address MAC address of the Ethernet port
State Changed Time State Changed Time
State Changed Cause State Change Cause
In-position information of optic module Indicating In-position information of optic module.This field is displayed when only the status of the port in GOUc, or GOUa is
queried
Factory information of optic module Indicating the factory information of optic module.This field is displayed when only the status of the port in GOUc, or GOUa is
queried
Optic module type Indicating the type of optic module.This field is displayed when only the status of the port in GOUc is queried
Optic module velocity Indicating the velocity of optic module.This field is displayed when only the status of the port in GOUc, or GOUa is queried
Optic module transmit distance[m] Indicating the transmit distance of optic module, unit:m.This field is displayed when only the status of the port in GOUc, or
GOUa is queried
Optic wavelength The wavelength of optic module.This field is displayed when only the status of the port in GOUc, or GOUa is queried
Optic module transmit mode Optic module transmit mode.This field is displayed when only the status of the port in GOUc, or GOUa is queried
Max transmit unit Max transmit unit
Speed Transmission rate of the Ethernet port, value range: 10M, 100M, 1000M, Automation
Duplex Duplex mode of the Ethernet port, value range: Full, Half, Automation
Auto negotiation Indicating whether to enable auto negotiation, value range: Enable, Disable
Loopback Loopback mode of the Ethernet port, value range: No loopback, Line loopback, System loopback
Flow control mode Indicating whether to enable the flow control, value range: Disable, Tx flow control, Rx flow control, Tx and Rx are both full-
duplex flow control, HDFC Tx flow control, Not configured
Backup mode or not Indicating whether the Ethernet port is in backup mode, value range: Backup, Not backup
Primary flag Indicating whether the Ethernet port is primary, value range: Yes, No
Rx correct bytes Rx correct bytes.This field is displayed when only the status of the port in FG2a, or GOUa is queried
Display Ethernet Port State(DSP ETHPORT) Page 3 of 3

Domain Name Description


Rx bad bytes Rx bad bytes.This field is displayed when only the status of the port in FG2a, or GOUa is queried
Number of received Unicast frame Number of Multicast frames received. This field is displayed when only the status of the port in FG2a, or GOUa is queried
Number of received Multicast frame Number of multicast frames received. This field is displayed when only the status of the port in FG2a, or GOUa is queried
Number of received broadcast frame Number of broadcast frames received. This field is displayed when only the status of the port in FG2a, or GOUa is queried
Number of received frame which length valid ,but Number of received frame with valid length but CRC check error. This field is displayed when only the status of the port in
CRC check error FG2a, or GOUa is queried
Number of Frames received with VLAN flag Number of Frames with VLAN flag received. This field is displayed when only the status of the port in FG2a, or GOUa is
queried
Number of received PAUSE control frame Number of PAUSE control frames received. This field is displayed when only the status of the port in FG2a, or GOUa is
queried
Tx correct bytes Tx correct bytes. This field is displayed when only the status of the port in FG2a, or GOUa is queried
Tx bad bytes Tx bad bytes. This field is displayed when only the status of the port in FG2a, or GOUa is queried
Number of sent Unicast frame Number of Unicast frames sent. This field is displayed when only the status of the port in FG2a, or GOUa is queried
Number of sent Multicast frame Number of Multicast frames sent. This field is displayed when only the status of the port in FG2a, or GOUa is queried
Number of sent broadcast frame Number of broadcast frames sent. This field is displayed when only the status of the port in FG2a, or GOUa is queried
Number of sent frames which have valid Number of frames sent which have valid length but CRC check error. This field is displayed when only the status of the port in
length,but CRC check error FG2a, or GOUa is queried
Number of Frames sent with VLAN flag Number of Frames with VLAN flag sent. This field is displayed when only the status of the port in FG2a, or GOUa is queried
Number of sent PAUSE control frame Number of PAUSE control frames sent. This field is displayed when only the status of the port in FG2a, or GOUa is queried
Rx correct packages Number of correct packages received. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Tx correct packages Number of correct packages sent. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of received Pause frame Number of Pause frame received. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of sent Pause frame Number of Pause frame sent. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of received Package Bytes Number of Package Bytes received. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of sent Package Bytes Number of Package Bytes sent. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of Bad Uplink TAG packages Number of Bad Uplink TAG packages. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of Bad Uplink MAC packages Number of Bad Uplink MAC packages. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of Uplink Success packages Number of Uplink Success packages. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Rx check error packages Number of CRC check error packages received. This field is displayed when only the status of the port in FG2c, or GOUc is
queried
Number of Sent OAM Loopback packages Number of OAM Loopback packages sent. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of Sent 802.3AH packages Number of 802.3AH packages sent. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of received Unicast packages Number of Unicast packages received. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of received Multicast packages Number of Multicast packages received. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of received broadcast packages Number of broadcast packages received. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of received Jumbo frame Number of Jumbo frame received. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of Success Recieved VLAN Packages Number of Success VLAN Packages recieved. This field is displayed when only the status of the port in FG2c, or GOUc is
queried
Number of Success Recieved Non-VLAN Number of Success Non-VLAN Packages recieved. This field is displayed when only the status of the port in FG2c, or GOUc
Packages is queried
Number of Discard VLAN Packages With UNTAG Number of VLAN Packages With UNTAG discarded. This field is displayed when only the status of the port in FG2c, or GOUc
is queried
Number of Discard Non-VLAN Packages With Number of Non-VLAN Packages With TAG discarded. This field is displayed when only the status of the port in FG2c, or
TAG GOUc is queried
Number of sent Unicast packages Number of Unicast packages sent. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of sent Multicast packages Number of Multicast packages sent. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of sent broadcast packages Number of broadcast packages sent. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Number of sent Jumbo frame Number of Jumbo frame sent. This field is displayed when only the status of the port in FG2c, or GOUc is queried
Tx optical power[mw] Tx optical power[mw]. This field is displayed when only the status of the port in GOUc is queried
Rx optical power[mw] Rx optical power[mw]. This field is displayed when only the status of the port in GOUc is queried

Huawei Proprietary and Confidential


Copyright © Huawei Technologies Co., Ltd.