Street Lighting Calculation
Street Lighting Calculation
Street Lighting Calculation
Luminaire Used:
PHILIPS DigiStreet BGP762 LED180-4S/740 DW10 106W
Pole Height: 10m
Pole Spacing: 40m
Date: 27.03.2020
Operator: Arsalan Ahmed
Waste to Energy - Streetlighting Calculation
27.03.2020
Table of contents
Page 2
Waste to Energy - Streetlighting Calculation
27.03.2020
Luminous emittance 1:
Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can
CIE flux code: 33 71 97 100 90 be displayed for this luminaire.
Get your city ready for the future with DigiStreet Developed with the aim to
become your long term partner ,
the system ready architecture of DigiStreet enables you to enjoy the benefits of
connected lighting systems today and also gets the city ready for the
innovations to come!. Its two sockets enable you to connect directly to the
Philips CityTouch system and is also prepared to connect you to the future
innovations of IoT.
Next to this, each individual luminaire is uniquely identifiable, thanks to the
Philips Service tag application. With a simple scan of a QR code, placed on the
inside of the mast door, you gain instant access to the luminaire configuration,
making maintenance and programming operations faster and easier, no matter
what stage of the luminaire’s lifetime. Digistreet is also equipped with dedicated
light recipes that: 1) maintain an optimal ecosystems for bats or 2) preserve a
dark night sky.
Page 3
Waste to Energy - Streetlighting Calculation
27.03.2020
Light loss factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:5273
No. Pieces Designation (Correction Factor) F (Luminaire) [lm] F (Lamps) [lm] P [W]
PHILIPS BGP762 T25 1 xLED180-4S/740 DW10
1 93 16200 18000 106.0
(1.000)
Total: 1506600 Total: 1674000 9858.0
Page 4
Waste to Energy - Streetlighting Calculation
27.03.2020
Page 5
Waste to Energy - Streetlighting Calculation
27.03.2020
Page 7
Waste to Energy - Streetlighting Calculation
27.03.2020
Page 8
Waste to Energy - Streetlighting Calculation
27.03.2020
Scale 1 : 6473
No. Designation Type Grid Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
1 Calculation Surface 1 perpendicular 3 x 27 14 7.12 25 0.517 0.281
2 Calculation Surface 2 perpendicular 3 x 23 14 8.34 25 0.581 0.337
3 Calculation Surface 3 perpendicular 75 x 11 17 6.83 37 0.408 0.184
4 Calculation Surface 4 perpendicular 133 x 11 16 6.80 28 0.434 0.241
5 Calculation Surface 5 perpendicular 25 x 21 15 7.64 26 0.513 0.292
6 Calculation Surface 6 perpendicular 1 x 31 14 6.13 20 0.450 0.310
Summary of Results
Type Quantity Average [lx] Min [lx] Max [lx] u0 Emin / Emax
perpendicular 6 15 6.13 37 0.41 0.16
Page 9
Waste to Energy - Streetlighting Calculation
27.03.2020
Page 10
Waste to Energy - Streetlighting Calculation
27.03.2020
Grid: 3 x 27 Points
Page 12
Waste to Energy - Streetlighting Calculation
27.03.2020
Grid: 3 x 23 Points
Page 13
Waste to Energy - Streetlighting Calculation
27.03.2020
Grid: 75 x 11 Points
Page 14
Waste to Energy - Streetlighting Calculation
27.03.2020
Page 15
Waste to Energy - Streetlighting Calculation
27.03.2020
Grid: 25 x 21 Points
Page 16
Waste to Energy - Streetlighting Calculation
27.03.2020
Grid: 1 x 31 Points
Page 17