Luminaire Used:
PHILIPS DigiStreet BGP762 LED180-4S/740 DW10 106W
Pole Height: 10m
Pole Spacing: 40m

Avg. Lighting Level: 15 lux

Maintenance Factor: 0.8

Date: 27.03.2020
Operator: Arsalan Ahmed
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Table of contents

Waste to Energy - Streetlighting Calculation


Project Cover 1
Table of contents 2
PHILIPS BGP762 T25 1 xLED180-4S/740 DW10
Luminaire Data Sheet 3
Streetlighting Calculation
Planning data 4
Luminaire parts list 5
Luminaires (coordinates list) 6
Calculation surfaces (results overview) 9
3D Rendering 10
False Color Rendering 11
Exterior Surfaces
Calculation Surface 1
Value Chart (E, Perpendicular) 12
Calculation Surface 2
Value Chart (E, Perpendicular) 13
Calculation Surface 3
Value Chart (E, Perpendicular) 14
Calculation Surface 4
Value Chart (E, Perpendicular) 15
Calculation Surface 5
Value Chart (E, Perpendicular) 16
Calculation Surface 6
Value Chart (E, Perpendicular) 17

Page 2
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

PHILIPS BGP762 T25 1 xLED180-4S/740 DW10 / Luminaire Data Sheet

Luminous emittance 1:

Luminaire classification according to CIE: 100 Due to missing symmetry properties, no UGR table can
CIE flux code: 33 71 97 100 90 be displayed for this luminaire.
Get your city ready for the future with DigiStreet Developed with the aim to
become your long term partner ,
the system ready architecture of DigiStreet enables you to enjoy the benefits of
connected lighting systems today and also gets the city ready for the
innovations to come!. Its two sockets enable you to connect directly to the
Philips CityTouch system and is also prepared to connect you to the future
innovations of IoT.
Next to this, each individual luminaire is uniquely identifiable, thanks to the
Philips Service tag application. With a simple scan of a QR code, placed on the
inside of the mast door, you gain instant access to the luminaire configuration,
making maintenance and programming operations faster and easier, no matter
what stage of the luminaire’s lifetime. Digistreet is also equipped with dedicated
light recipes that: 1) maintain an optimal ecosystems for bats or 2) preserve a
dark night sky.

Page 3
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / Planning data

Light loss factor: 0.80, ULR (Upward Light Ratio): 0.0% Scale 1:5273

Luminaire Parts List

No. Pieces Designation (Correction Factor) F (Luminaire) [lm] F (Lamps) [lm] P [W]
PHILIPS BGP762 T25 1 xLED180-4S/740 DW10
1 93 16200 18000 106.0
(1.000)
Total: 1506600 Total: 1674000 9858.0

Page 4
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / Luminaire parts list

93 Pieces PHILIPS BGP762 T25 1 xLED180-4S/740 DW10


Article No.:
Luminous flux (Luminaire): 16200 lm
Luminous flux (Lamps): 18000 lm
Luminaire Wattage: 106.0 W
Luminaire classification according to CIE: 100
CIE flux code: 33 71 97 100 90
Fitting: 1 x LED180-4S/740 (Correction Factor
1.000).

Page 5
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]
Streetlighting Calculation / Luminaires (coordinates list)

PHILIPS BGP762 T25 1 xLED180-4S/740 DW10


16200 lm, 106.0 W, 1 x 1 x LED180-4S/740 (Correction Factor 1.000).

No. Position [m] Rotation [°]


X Y Z X Y Z
1 104.835 415.590 10.000 0.0 0.0 -110.0
2 99.156 337.670 10.000 0.0 0.0 -90.0
3 99.156 294.743 10.000 0.0 0.0 -90.0
4 99.156 254.243 10.000 0.0 0.0 -90.0
5 99.156 173.157 10.000 0.0 0.0 -90.0
6 102.000 134.200 10.000 0.0 0.0 -55.0
7 130.544 119.500 10.000 0.0 0.0 0.0
8 215.745 119.500 10.000 0.0 0.0 0.0
9 306.947 119.500 10.000 0.0 0.0 0.0
10 388.900 118.800 10.000 0.0 0.0 0.0
11 469.950 119.500 10.000 0.0 0.0 0.0
12 507.400 127.100 10.000 0.0 0.0 35.0
13 513.347 150.781 10.000 0.0 0.0 90.0
14 513.347 189.061 10.000 0.0 0.0 90.0
15 513.347 269.616 10.000 0.0 0.0 90.0
16 472.351 237.007 10.000 0.0 0.0 180.0
17 407.197 227.362 10.000 0.0 0.0 0.0
18 331.568 222.600 10.000 0.0 0.0 0.0
19 331.379 215.094 10.000 0.0 0.0 180.0
20 291.019 215.707 10.000 0.0 0.0 180.0
21 291.019 221.514 10.000 0.0 0.0 0.0
22 248.400 222.300 10.000 0.0 0.0 0.0
23 248.891 215.908 10.000 0.0 0.0 180.0
24 212.716 225.870 10.000 0.0 0.0 -90.0
25 213.111 306.872 10.000 0.0 0.0 -90.0
26 212.714 346.916 10.000 0.0 0.0 -90.0
27 200.500 383.200 10.000 0.0 0.0 -40.0
28 171.133 413.233 10.000 0.0 0.0 -40.0
Page 6
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]
Streetlighting Calculation / Luminaires (coordinates list)

No. Position [m] Rotation [°]


X Y Z X Y Z
29 234.300 416.000 10.000 0.0 0.0 0.0
30 234.403 411.025 10.000 0.0 0.0 180.0
31 279.030 411.141 10.000 0.0 0.0 180.0
32 278.817 416.200 10.000 0.0 0.0 0.0
33 318.307 416.200 10.000 0.0 0.0 0.0
34 318.443 411.201 10.000 0.0 0.0 180.0
35 356.862 415.958 10.000 0.0 0.0 0.0
36 356.967 411.000 10.000 0.0 0.0 180.0
37 400.511 411.053 10.000 0.0 0.0 180.0
38 400.387 416.393 10.000 0.0 0.0 0.0
39 443.800 416.300 10.000 0.0 0.0 0.0
40 443.800 410.600 10.000 0.0 0.0 180.0
41 237.661 546.328 10.000 0.0 0.0 -90.0
42 260.002 522.861 10.000 0.0 0.0 0.0
43 301.573 521.500 10.000 0.0 0.0 0.0
44 382.200 515.300 10.000 0.0 0.0 0.0
45 454.600 510.600 10.000 0.0 0.0 0.0
46 533.000 502.500 10.000 0.0 0.0 -5.0
47 419.607 541.434 10.000 0.0 0.0 -90.0
48 613.459 493.331 10.000 0.0 0.0 -5.0
49 677.200 480.800 10.000 0.0 0.0 -60.0
50 691.700 509.400 10.000 0.0 0.0 -145.0
51 723.435 503.019 10.000 0.0 0.0 120.0
52 721.581 468.238 10.000 0.0 0.0 20.0
53 710.722 422.536 10.000 0.0 0.0 -130.0
54 689.878 437.813 10.000 0.0 0.0 -110.0
55 688.200 438.400 10.000 0.0 0.0 75.0
56 659.717 404.890 10.000 0.0 0.0 0.0
57 659.890 400.931 10.000 0.0 0.0 180.0
58 666.568 377.712 10.000 0.0 0.0 -135.0
59 611.425 400.627 10.000 0.0 0.0 180.0
60 611.228 404.572 10.000 0.0 0.0 0.0
61 540.261 403.840 10.000 0.0 0.0 0.0
62 540.607 399.888 10.000 0.0 0.0 180.0
63 494.120 349.620 10.000 0.0 0.0 -90.0
64 488.307 349.759 10.000 0.0 0.0 90.0
65 526.827 332.909 10.000 0.0 0.0 -90.0
66 537.600 314.100 10.000 0.0 0.0 0.0

Page 7
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / Luminaires (coordinates list)

No. Position [m] Rotation [°]


X Y Z X Y Z
67 519.096 292.093 10.000 0.0 0.0 180.0
68 578.381 292.294 10.000 0.0 0.0 180.0
69 609.215 301.049 10.000 0.0 0.0 -125.0
70 593.454 312.510 10.000 0.0 0.0 0.0
71 591.600 334.500 10.000 0.0 0.0 -90.0
72 628.733 331.023 10.000 0.0 0.0 -130.0
73 633.689 356.929 10.000 0.0 0.0 180.0
74 573.951 356.211 10.000 0.0 0.0 180.0
75 589.650 277.312 10.000 0.0 0.0 -180.0
76 353.965 170.583 10.000 0.0 0.0 -90.0
77 100.200 376.643 10.000 0.0 0.0 -90.0
78 99.500 215.100 10.000 0.0 0.0 -90.0
79 170.378 119.200 10.000 0.0 0.0 0.0
80 262.131 119.100 10.000 0.0 0.0 0.0
81 348.189 118.800 10.000 0.0 0.0 0.0
82 428.823 118.600 10.000 0.0 0.0 0.0
83 513.347 228.416 10.000 0.0 0.0 90.0
84 213.300 267.279 10.000 0.0 0.0 -90.0
85 573.824 498.428 10.000 0.0 0.0 -5.0
86 495.136 507.053 10.000 0.0 0.0 -5.0
87 420.700 512.900 10.000 0.0 0.0 0.0
88 651.264 490.586 10.000 0.0 0.0 -5.0
89 468.900 413.800 10.000 0.0 0.0 -85.0
90 215.400 414.700 10.000 0.0 0.0 115.0
91 359.500 222.100 10.000 0.0 0.0 0.0
92 359.405 217.004 10.000 0.0 0.0 -175.0
93 341.971 520.457 10.000 0.0 0.0 0.0

Page 8
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / Calculation surfaces (results overview)

Scale 1 : 6473

Calculation Surface List

No. Designation Type Grid Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
1 Calculation Surface 1 perpendicular 3 x 27 14 7.12 25 0.517 0.281
2 Calculation Surface 2 perpendicular 3 x 23 14 8.34 25 0.581 0.337
3 Calculation Surface 3 perpendicular 75 x 11 17 6.83 37 0.408 0.184
4 Calculation Surface 4 perpendicular 133 x 11 16 6.80 28 0.434 0.241
5 Calculation Surface 5 perpendicular 25 x 21 15 7.64 26 0.513 0.292
6 Calculation Surface 6 perpendicular 1 x 31 14 6.13 20 0.450 0.310

Summary of Results

Type Quantity Average [lx] Min [lx] Max [lx] u0 Emin / Emax
perpendicular 6 15 6.13 37 0.41 0.16

Page 9
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / 3D Rendering

Page 10
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]
Streetlighting Calculation / False Color Rendering
Page 11
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / Calculation Surface 1 / Value Chart (E, Perpendicular)

Values in Lux, Scale 1 : 1940


Not all calculated values could be displayed.

Position of surface in external scene:


Marked point:
(102.300 m, 145.569 m, 0.000 m)

Grid: 3 x 27 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


14 7.12 25 0.517 0.281

Page 12
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / Calculation Surface 2 / Value Chart (E, Perpendicular)

Values in Lux, Scale 1 : 1086


Not all calculated values could be displayed.

Position of surface in external scene:


Marked point:
(499.400 m, 146.119 m, 0.000 m)

Grid: 3 x 23 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


14 8.34 25 0.581 0.337

Page 13
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / Calculation Surface 3 / Value Chart (E, Perpendicular)

Values in Lux, Scale 1 : 1849


Not all calculated values could be displayed.

Position of surface in external scene:


Marked point:
(213.218 m, 416.898 m, 0.000 m)

Grid: 75 x 11 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


17 6.83 37 0.408 0.184

Page 14
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / Calculation Surface 4 / Value Chart (E, Perpendicular)

Values in Lux, Scale 1 : 2986


Not all calculated values could be displayed.

Position of surface in external scene:


Marked point:
(240.008 m, 542.422 m, 0.000 m)

Grid: 133 x 11 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


16 6.80 28 0.434 0.241

Page 15
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / Calculation Surface 5 / Value Chart (E, Perpendicular)

Values in Lux, Scale 1 : 1090


Not all calculated values could be displayed.

Position of surface in external scene:


Marked point:
(214.202 m, 224.300 m, 0.000 m)

Grid: 25 x 21 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


15 7.64 26 0.513 0.292

Page 16
Waste to Energy - Streetlighting Calculation
27.03.2020

Signify International B.V. Operator Arsalan Ahmed


Telephone +971 52640 0204
Dubai, UAE Fax
e-Mail [email protected]

Streetlighting Calculation / Calculation Surface 6 / Value Chart (E, Perpendicular)

Values in Lux, Scale 1 : 2589


Not all calculated values could be displayed.

Position of surface in external scene:


Marked point:
(488.887 m, 121.441 m, 0.000 m)

Grid: 1 x 31 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax


14 6.13 20 0.450 0.310