Tips Hyper Works
Tips Hyper Works
Tips Hyper Works
Applications:
OptiStruct
Application version:
OptiStruct 7.0 or higher
Computer hardware:
All supported
Categories: Subcategories
Analysis: Setup and Theory
Topic:
Nonlinear (iterative) solutions using gap elements
Topic details:
Beginning with OptiStruct 7.0, a non-linear solution sequence is available for modeling contact problems.
Any model with non-linear CGAP (gap) elements uses the non-linear solution sequence. The element can
be used for both static analysis and optimization; however, the assumptions of small displacement and
small strain still apply.
Note: Gap elements can also be created with the no vector option (in HyperMesh) in which no
orientation is specified for the gap element. In such a case, the line joining the first node and the
second node will be taken as the element X-axis. Again, consult the online help for details.
Author:
Altair HyperWorks Technical Support Group (MHS)