Beam Bolted Splice Design Based On AISC 360-10/16: Input Data & Design Summary

This document summarizes the design of a bolted splice connecting two W21x48 beams. Key details include: - The splice connects the beams with 6 bolts in each of the flanges and 6 bolts in each of the webs. - Checks are performed to ensure the bolt shear capacity, plate capacities in tension and shear, and block shear capacities are adequate for the applied loads of 70 kips axial, 100 kips shear, and 80 ft-kips moment. - All capacity checks are satisfactory, indicating the splice design is adequate.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
563 views1 page

Beam Bolted Splice Design Based On AISC 360-10/16: Input Data & Design Summary

This document summarizes the design of a bolted splice connecting two W21x48 beams. Key details include: - The splice connects the beams with 6 bolts in each of the flanges and 6 bolts in each of the webs. - Checks are performed to ensure the bolt shear capacity, plate capacities in tension and shear, and block shear capacities are adequate for the applied loads of 70 kips axial, 100 kips shear, and 80 ft-kips moment. - All capacity checks are satisfactory, indicating the splice design is adequate.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Beam Bolted Splice Design Based on AISC 360-10/16

INPUT DATA & DESIGN SUMMARY (Flange Plate 5.71 in x 19.5 in x 1 in)
WF BEAM SECTION = > W21X48
WF STEEL YIELD STRESS Fy = 50 ksi
PLATE STEEL YIELD STRESS F yp = 36 ksi
FLANGE PLATE THICKNESS t fp = 1 in
WEB PLATE THICKNESS t wp = 0.75 in

BEAM AXIAL LOAD, ASD T = 70 kips, ( 20% WF's Pn / Wt)


VERTICAL SHEAR FORCE, ASD V = 100 kips, ( 69% WF's Vn / Wv)
MOMENT AT SPLICE, ASD M = 80 ft-k, ( 30% WF's Mn / Wb)

BOLT DIAMETER f = 1 in ( 1 in)


BOLT MATERIAL (A307, A325, A490) ASTM = A325
HOLE TYPE (STD, NSL, OVS, SSL, LSL) => STD
STD = Standard round holes ( d + 1/16 " )
NSL = Long or short-slotted hole normal to load direction
OVS = Oversize round holes
SSL = Short-slotted holes (Web Plate 9.5 in x 13.5 in x 0.75 in)
LSL = Long-slotted holes
CONNECTION TYPE (SC, N, X) => N
SC = Slip critical connection THE DESIGN IS ADEQUATE.
N = Bearing-type connection with threads included in the shear plane
X = Bearing-type connection with threads excluded from the shear plane
FLANGE BOLTS 2 rows 3 bolts on each row (total 6 bolts at each end)
WEB BOLTS 2 vert rows 3 bolts on each row (total 6 bolts at each end)

ANALYSIS
SECTION PROPERTIES (AISC Manual Table 1)
d tw tf k bf A Zx
20.6 0.35 0.43 0.93 8.14 14.1 107

DETERMINE PLATE DIMENSIONS


Bolt spacing required = 3.00 in, (Tab J3.3) Bolt spacing used = 3.00 in [Satisfactory]
Edge spacing required = 1.75 in, (Tab J3.4) Edge spacing used = 1.75 in [Satisfactory]
Flange Plate B = 5.71 in < bf [Satisfactory]
L fp = 19.5 in
Web Plate D = 9.5 in < d - 2k [Satisfactory]
L wp = 13.5 in

CHECK CAPACITY OF BOLTS (AISC 360 J3)


Allowable shear capacity R n / Wv = 18.8 kips / bolt, (AISC Manual Table 7)
Flange bolt shear v = T / AT + M / S = 11.7 kips / bolt < R n / Wv [Satisfactory]
Web bolt shear v = [(T / A T ) 2 + (V / A V ) 2 ] 0.5 = 17.1 k / bolt < R n / Wv [Satisfactory]
where AT = 18 bolts, (total one end bolts)
S= 123.6 in-bolts, (flange bolts only)
AV = 6 bolts, (one end web bolts only)

CHECK WEB PLATE FOR SHEAR CAPACITY (AISC 360 G2)


V / (D t wp ) = 14.0 ksi < 0.6 F yp C v / W v = 0.6 F yp 1.0 / 1.5 = 14.4 ksi [Satisfactory]

CHECK FLANGE PLATE FOR TENSION CAPACITY (AISC 360 D)


T / (2 B t fp + D t wp ) + M / (d B t fp ) = 11.9 ksi < F yp / W t = F yp / 1.67 = 21.56 ksi [Satisfactory]

CHECK FLANGE NET TENSION FRACTURE (AISC 360 J4.1)


F up = 58 ksi ( for plate, AISC Manual page. 2-39)
0.5 T + M / d = 81.60 kips < F up / W [ B - n (d s + 1/8 ) ] t fp = 100 kips [Satisfactory]

CHECK FLANGE NET SHEAR FRACTURE (AISC 360 J4.2)


Fu = 65 ksi ( for WF, AISC Manual page. 2-39)
0.5 T + M / d = 81.60 kips < 0.6 Min( F u t f , F up t fp ) / W ( S shear length) = 82.80 kips
[Satisfactory]
CHECK WEB PLATE BLOCK SHEAR (AISC 360 J4)
lh = 4.9 in
lv = 1.2 in
V = 100.00 kips < 0.6 A v F up / W + A t F up / W = (0.3 l v + 0.5 l h ) t wp F up = 122.89 kips
[Satisfactory]