DWQH PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 52

GSC 12 DGN 3 DWQH GSC 12 RGN 3 DWQH GSC 12 TGN 3 DWQH

Cooling Cooling Cooling

230 V 230 V 230 V

50 Hz/1Ø 50 Hz/1Ø 50 Hz/1Ø

3500 W 3500 W 3500 W

986 W 986 W 986 W

660 CMH 660 CMH 660 CMH

4.52 A 4.52 A 4.52 A

R32 R32 R32

0.64 kg 0.64 kg 0.64 kg

25.0 A 25.0 A 25.0 A

11.0 kg 11.0 kg 11.0 kg

30.0 kg 30.0 kg 30.0 kg


Content
Operation Notices
The Refrigerant ....................................................................................................1
Precautions .......................................................................................................... 2
Parts Name ......................................................................................................... 8
Screen Operation Guide
Buttons on remote controller ............................................................................ 10
Introduction for icons on display screen ........................................................... 10
Introduction for buttons on remote controller ..................................................... 11
Function introduction for combination buttons.................................................... 15
Operation guide ................................................................................................. 16
Replacement of batteries in remote controller ................................................... 16
Emergency operation .........................................................................................17
Maintenance
Clean and Maintenance .....................................................................................17
Malfunction
Malfunction analysis .......................................................................................... 20
Installation Notice
Installation dimension diagram .......................................................................... 24
Safety precautions for installing and relocating the unit..................................... 25
Tools for installation ........................................................................................... 26
Selection of installation location ......................................................................... 26
Requirements for electric connection ................................................................ 27
Installation
Installation of indoor unit .................................................................................... 28
Installation of outdoor unit ................................................................................. 33
Vacuum pumping ............................................................................................... 36
Leakage detection ............................................................................................. 36
Check after installation ...................................................................................... 37
Test and operation
Test operation ................................................................................................... 37
Attachment
Configuration of connection pipe ....................................................................... 38
Safety operation of flammable refrigerant ......................................................... 40
Pipe expanding method ..................................................................................... 42
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If it needs to install, move or maintain the air conditioner, please contact dealer or local service center
to conduct it at first. Air conditioner must be installed, moved or maintained by appointed unit. Otherw-
ise, it may cause serious damage or personal injury or death.
Explanation of Symbols

Indicates a hazardous situation that, if not avoided, will


DANGER result in death or serious injury.

Indicates a hazardous situation that, if not avoided, could


WARNING result in death or serious injury.

Indicates a hazardous situation that, if not avoided, may


CAUTION result in minor or moderate injury.
Indicates important but not hazard-related information,
NOTICE used to indicate risk of property damage.

Indicates a hazard that would be assigned a signal word


WARNING or CAUTION.
Appliance filled with flammable gas R32.

Before use the appliance, read the owner’s manual first.

Before install the appliance, read the installation manual first.

Before repair the appliance, read the service manual first.

The Refrigerant
To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R32, which is specially cleaned.
The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion
under certain conditions. But the flammability of the refrigerant is very low. It can
be ignited only by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.

WARNING:
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture. Should repair be necessary, contact your nea-
rest authorized Service Centre. Any repairs carried out by unqualified personnel
may be dangerous. The appliance shall be stored in a room without continuously
operating ignition sources. (for example: open flames, an operating gas appliance
or an operating electric heater.) Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a floor area larger
than X m 2. (Please refer to table "a" in section of " Safety Operation of Inflammable
Refrigerant" for Space X.)
Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s
instructions only. Be aware that refrigrants not contain odour. Read specialist’s
manual.

1
Precautions

WARNING

Operation and Maintenance


This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory ormental capabilities or lack of experience and
knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shock. .
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid
electric shock.
Do not spray water on indoor unit. It may cause electric
shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.

2
Precautions

WARNING

Maintenance must be performed by qualified


professionals. Otherwise, it may cause personal injury
or damage.
Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause
malfunction.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately, and then
contact the dealer or qualified professionals for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.

If the air conditioner operates under abnormal conditions,


it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.

3
Precautions

WARNING

Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note the following table. Air switch should be included
magnet buckle and heating buckle function, it can protect
the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the
requirement of air conditioner. Unstable power supply or
incorrect wiring or malfunction. Please install proper power
supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.

4
Precautions

WARNING

Do not put through the power before finishing installation.


If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
The appliance shall be installed in accordance with
national wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only
The air conditioner is the first class electric appliance. It
must be properly grounding with specialized grounding
device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
The grounding resistance should comply with national
electric safety regulations.
The appliance must be positioned so that the plug is
accessible.
All wires of indoor unit and outdoor unit should be
connected by a professional.
If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the
wire by yourself.

5
Precautions

WARNING
For the air conditioner with plug, the plug should be
reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall
Please notice that the unit is filled with flammable gas
R32. Inappropriate treatment of the unit involves the
risk of severe damages of people and material. Details
to this refrigerant are found in chapter “refrigerant”.
Check whether the maintenance area or the room area
meet the requirement of the nameplate.
- It’s only allowed to be operated in the rooms that meet
the requirement of the nameplate.
Check whether the maintenance area is well-ventilated.
- The continuous ventilation status should be kept
during the operation process.
Check whether there is fire source or potential fire source
in the maintenance area.
- The naked flame is prohibited in the maintenance area;
and the “no smoking” warning board should be hanged.
Check whether the appliance mark is in good condition.
- Replace the vague or damaged warning mark.
Please use the flammable gas detector to check before
unload and open the container.
No fire source and smoking.
According to the local rules and laws.
6
Precautions

WARNING

The air conditioner is not allowed to use in a room that


has running fire (such as fire source, working coal gas
ware, operating heater).
It is not allowed to drill hole or burn the connection pipe.
The air conditioner must be installed in a room that is
larger than the minimum room area. The minimum room
area is shown on the nameplate or following table a.
Leak test is a must after installation.
Instructions for installation and use of this product are
provided by the manufacturer.

Working temperature range

Indoor side DB/WB(℃ ) Outdoor side DB/WB(℃ )


Maximum cooling 35/24 48/30
Maximum heating 27/- 24/18

NOTICE:
● The operating temperature range (outdoor temperature) for cooling only unit is
18℃ ~ 48℃ ; for heat pump unit is -7℃ ~ 48℃ .

7
Parts Name
Indoor Unit

air inlet
panel

aux.button

horizontal louver
air outlet
AIR HEALTH X-FAN
HUMIDITY
FILTER
TURBO
HOUR
ON/OFF

ON/OFF MODE

FAN

X-FAN TEMP TIMER

TURBO SLEEP LIGHT

(Display content or position may be different from above remote control


graphics, please refer to actual products)

Outdoor Unit
air inlet

Connection wire

air outlet

NOTICE:
Actual product may be different from above graphics, please refer to actual
products.

8
Parts name
Display

For some model: For some model:


temp.
cooling power receiver indicator
indicator indicator window heating
indicator
display
cooling
indicator
power receiver
heating temp. drying indicator window
display
indicator indicator indicator
drying
indicator
For some model:
display

temp.
indicator Power LED color indicator:
receiver Green-status-ON.
window Red -status-OFF.

Mode LED color indicator:


W R G White-W-Cool Mode-
W

Red-R-Heat Mode- R
(only for heating model)

Green-G-Dry Mode- G
For some model:
For some model: Power indicatior
display

temp. temp.
indicator indicator
Power LED color indicator: display
receiver Green-status-ON.
window Red -status-OFF.
receiver
Mode LED color indicator: window
W R O
White-W-Cool Mode-
W
Red-R-Heat Mode- R
(only for heating model)
Orange-O-Dry Mode- O

Display content or position may be different from above graphics, please refer to actual
products.

9
Buttons on remote controller
FAN AUTO 1 ON/OFF button
OPER
AIR HEALTH X-FAN
HUMIDITY
2 MODE button
FILTER 3 +/- button
TURBO
HOUR 4 FAN button
ON/OFF

5 button
1 2 6 button
ON/OFF MODE

3 7 HEALTH SAVE button


8 X-FAN button
4 5 (Note: X-FAN is same with BLOW)
FAN
7 6 9 TEMP button
8 10 10 TIMER button
X-FAN TEMP TIMER
9 11 TURBO button
TURBO SLEEP LIGHT
11 13 12 SLEEP button
12 13 LIGHT button

Introduction for icons on display screen


set fan speed
air mode FAN AUTO send signal
OPER
Operation mode health mode
AIR HEALTH X-FAN
Auto mode X-fan
HUMIDITY
Cool mode
Dry mode FILTER set temperature
Fan mode TURBO turbo mode
Heat mode HOUR TIMER ON/TIMER OFF
ON/OFF

Child Lock set time


Sleep mode left & right swing
Temp. display type
:Set temp. Up & down swing
light
:Indoor ambient temp.
:Outdoor ambient temp.

10
Introduction for buttons on remote controller
Note:
● This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model doesn't have, if press
the corresponding button on the remote controller that the unit will keep the
original running status.
● After putting through power, air conditioner will give out a sound and operation
indicator " " is ON (red indicator, the colour is different for different models).
You can operate the air conditioner through the remote controller.
● At ON status, after each pressing button on remote controller, the signal icon " "

indicates the signal has been sent to air conditioner.


● At OFF status, display screen on remote controller displays set temperature.
At on status, display screen on remote controller displays the corresponding startup
function’s icon.
1 ON/OFF button
Press this button to turn on the unit. Press this button again to turn off the unit.
2 MODE button
Press this button can select your required operation mode.
AUTO COOL DRY FAN HEAT

● After selecting auto mode, air conditioner will operate automatically according to
ambient temperature. Set temperature can’t be adjusted and also can’t be displa-
yed. Press"FAN" button can adjust fan speed. Press " " button can adjust swing angle.
● After selecting cool mode, air conditioner operates under cool mode. Cool indicator
" " on indoor unit is ON (This indicator is not available for some models). You can
press "+" or "-" button to adjust set temperature. Press "FAN" button can adjust fan
speed. Press " " button can adjust swing angle.
● After selecting dry mode, air conditioner operates under dry mode at low speed.
Dry indicator " " on indoor unit is ON (This indicator is not available for some
models). Under dry mode, fan speed can’t be ad justed. Press " " button to adjust
swing angle.
● After selecting fan mode, air conditioner operates only under fan mode, All mode
indicators on indoor unit is OFF. Operation indicator is ON.(This indicator is not available for
some models). Press "FAN" button can adjust fan speed. Press " " button to adjust swing angle.
● After selecting heat mode, air conditioner operates under heat mode. Heat indicator
" " on indoor unit is ON(This indicator is not available for some models).
You can press "+" or "-" button to adjust set temperature.
Press "FAN" button to adjust fan speed. Press " " button to adjust swing angle.
(Cooling only unit can’t receive the signal for heating mode.)

11
Introduction for buttons on remote controller
Note:
For preventing cold wind, after starting up heating mode, indoor fan will blow fan
afterdelaying 1-5min. (Details time is decided by indoor ambient temperature)
Temperature setting range on remote controller: 16℃ -30℃ . Fan speed setting
range: auto, low speed, medium speed and high speed.

3 "+" or "-" button


● After each pressing of "+" or "-" button, it can increase or decrease set temper-
ature 1℃ . Hold "+" or "-" button, 2s later, set temperature on remote controller
will change quickly. After reaching to your required time, loosen the button.
Temperature indicator on indoor unit will also change accordingly. (Temperature
can’t be adjusted under auto mode)
● Under TIMER ON, TIMER OFF or Clock setting, you can press "+"or "-" button to
adjust time. (Refer to TIMER button for details)

4 FAN button
Pressing this button can set fan speed circularly as: auto (AUTO), low( ),
medium( ), high( ).

Auto

Note:
● Under AUTO Speed,IDU fan motor will adjust the fan speed (high, medium or
low speed) according to ambient temperature.
● Fan speed under dry mode is low speed.

5 button

● Press this button to start or stop up & down swing function.The remote controller
defaults to simple swing condition.
● Press + button and button at the same time at unit OFF to switch between
simple swing and static swing; blinks for 2 seconds.
● In static swing condition, pressing button, the swing angle of up & down louver
changes as below:

no display
(horizontal louvers stops
at current position)
● If the unit is turned off during swing operation,the louver will stop at present
position.
12
Introduction for buttons on remote controller
Note:
When selecting " " with remote controller, it’s auto swing. Horizontal louver of air
conditioner will swing up&down automatically at the maximum angle.
When selecting " 、 、 、 、
swing. Horizontal louver of air conditioner will stop at that position as shown by the
icon to swing.

6 button
● Press this button to start or stop left & right swing function. The remote controller
defaults to simple swing condition.
● Press + button and button at the same time at unit OFF to switch between
simple swing and static swing; blinks for 2 seconds.
● In static swing condition, pressing button, the swing angle of left & right louver
changes as below:

no display
(horizontal louvers stops (swing angle is dis-
at current position) played dynamically)
● If the unit is turned off during swing operation,the louver will stop at present
position.
● When selecting " " with remote controller, it’s auto swing. Horizontal louver of
air conditioner will swing left&right automatically at the maximum angle.
● When selecting " 、 、 、 、 "
position swing. Horizontal louver of air conditioner will stop at that position as
shown by the icon to swing.
● When selecting " ", it’s the circulating swing. Horizontal louver of
(swing angle is displayed dynamically)

air conditioner will swing circularly according to the angle as shown by the icon.
Note: There is no this function for the units. If press this key, the main unit will
click, but it also runs under original status.
7 HEALTH SAVE button
HEALTH FUNCTION:
After pressing HEALTH button, remote controller will switch circularly as below:
"HEALTH"→"AIR"→"AIR HEALTH"→"no display"
● When selecting "HEALTH" by remote controller, HEALTH function will be started up.
● When selecting "AIR" by remote controller, AIR function will be started up.
● When selecting "AIT HEALTH", AIR and HEALTH function will be started up.
● When there’s no display on remote controller, AIR and HEALTH function will be
turned off.
● AIR function is applicable for some models.
● HEALTH function is applicable for some models.
13
Introduction for buttons on remote controller
SAVE function:
Under cool mode, press SAVE button and the unit will operate under SAVE mode.
Dual-8nixie tube on remote controller displays "SE". Air conditioner will operate at
auto speed. Set temperature can’t be adjusted. Press SAVE button again to exit
SAVE mode. Air conditioner turn back to original set speed and set temperature.

8 X-FAN button
After pressing this button under cooling or dry mode, remote controller displays the
character of "X-FAN" and X-FAN function is started up. Press this button again to
cancel X-FAN function. The character of "X-FAN" will disappear.
Note:
● After starting up X-FAN function, when turning off the unit, indoor fan will continue
to operate for a while at low speed to dry the residual water inside the indoor unit.
● When the unit operates under X-FAN mode, press "X-FAN" button can turn off
X-FAN function. Indoor fan stops operation immediately.

9 TEMP button
Press this button can see indoor set temperature, indoor ambient temperature or
outdoor ambient temperature on indoor unit’s display. Temperature is set circularly
by remote controller as below:
no display

● When selecting " " by remote controller or no display, temperature indicator on


indoor unit displays set temperature.
● When selecting " " by remote controller, temperature indicator on indoor unit
displays indoor ambient temperature.
● When selecting " " by remote controller, temperature indicator on indoor unit
displays outdoor ambient temperature.
Note:
● Outdoor ambient temperature display may can’t be selected for some models.
When indoor unit receives " " signal, it displays indoor set temperature.
● Only for the model whose indoor unit has dual-8 display.

10 TIMER button
● At ON status, press this button once can set TIMER OFF. The character of HOUR
TIMER
ON. After each pressing of "+" or "-" button, time will increase or decrease half an

14
Introduction for buttons on remote controller
hour. When holding "+" or "-" button, 2s later, the time will change quickly until to

Cancel TIMER OFF: Press "TIMER" button again under TIMER OFF status.
● At OFF status, press this button once can set TIMER ON. Please refer to TIMER
off for detailed operation.
Cancel TIMER ON: Press "TIMER" button again under TIMER ON status.
Note:
● Time setting range: 0.5-24 hours.
● Time interval between two operations can’t exceed 5s. Otherwise, remote
controller will exit the setting status automatically.

11 TURBO button
When pressing this button under cooling or heating mode, air conditioner will enter
into quick cooling or quick heating mode. The character of "TURBO" is displayed
on remote controller. Press this button again to exit turbo function and the character
of "TURBO" will be disappeared on remote controller.

12 SLEEP button
Press this button under cooling, heating mode can start up sleep function.
" " icon will be displayed on remote controller. Press this button again to cancel
sleep function. " "icon on remote controller will be displayed.

13 LIGHT button
Press this button can turn off the light for indoor unit’s display. " " icon on remote
controller will disappear. Press this button again to turn on the light for indoor unit’s
display. " " icon on remote controller will be displayed.

Function introduction for combination buttons


Child lock function
Press "+" and "-" buttons simultaneously can turn on or turn off child lock function.
When child lock function is started up, " " icon will be displayed on remote

controller won’t send signal.

Switchover function for temperature display


After turning off the unit by remote controller, press "-" button and "MODE" button
simultaneously to switch between ℃ and °F .

15
Operation guide
1. After putting through the power, press " ON/OFF " button on remote controller to
turn on the air conditioner.
2. Press " MODE " button to select your required mode: AUTO, COOL, DRY, FAN,
HEAT.
3. Press "+" or "-" button to set your required temperature. (Temperature can’t be
adjusted under auto mode).
4. Press " FAN " button to set your required fan speed: auto, low, medium and
high speed.
5. Press " " button to select fan blowing angle.

Replacement of batteries in remote controller


1. Press the back side of remote controller marked signal sender battery

the cover of battery box along the arrow direction. reinstall


2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "+" polar and "-" polar remove
are correct.
3. Reinstall the cover of battery box.
Cover of battery box

NOTICE
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
● The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.

or wireless telephone; remote controller should be close to indoor unit during


operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please
replace batteries.

16
Emergency operation

If remote controller is lost or damaged, please use auxiliary button to turn


on or turn off the air conditioner. The operation in details are as below:

air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
panel
aux. button

WARNING:
Use insulated object to press the auto button

Clean and maintenance


WARNING
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.

■ Do not wash the air conditioner with water to avoid electric shock.

■ Do not use volatile liquid to clean the air conditioner.

Clean surface of indoor unit


When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
NOTICE:
● Do not remove the panel when cleaning it.

17
Clean and maintenance

Open panel
1 Pull out the panel to a certain
3 ● Use dust catcher or water to

the water (below 45℃ ) to clean


it, and then put it in a shady
and cool place to dry.

4
panel cover tightly.

WARNING

operation environment, clean frequency can be increased.

18
Clean and maintenance

NOTICE: Checking before use-season

1. Check whether air inlets and air outlets are blocked.


2. Check whether air switch, plug and socket are in good condition.

4. Check whether mounting bracket for outdoor unit is damaged or corroded.


If yes, please contact dealer.
5. Check whether drainage pipe is damaged.

NOTICE: Checking after use-season

1. Disconnect power supply.

3. Check whether mounting bracket for outdoor unit is damaged or corroded.


If yes, please contact dealer.

Notice for recovery


1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.

19
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still

Phenomenon Check items Solution

● Whether it's interfered severely ● Pull out the plug. Reinsert


(such as static electricity, stable the plug after about 3min, and
voltage)? then turn on the unit again.
● Whether remote controller is
within the signal receiving ● Signal receiving range is 8m.
range?
Indoor unit ● Whether there are obstacles? ● Remove obstacles.
can’t receive ● Whether remote controller is ● Select proper angle and point
remote pointing at the receiving the remote controller at the re-
controller’s window? ceiving window on indoor unit.
signal or
● Is sensitivity of remote contro- ● Check the batteries. If the
remote
ller low; fuzzy display and no power of batteries is too low,
controller
display? please replace them.
has no
action. ● Check whether remote cont-
● No display when operating
roller appears to be damaged.
remote controller?
If yes, replace it.
● Take the remote controller
● Fluorescent lamp in room? close to indoor unit.

and then try it again.

● Air inlet or air outlet of indoor ● Eliminate obstacles.


unit is blocked?
● Under heating mode, indoor ● After reaching to set temper-
No air temperature is reached to set ature, indoor unit will stop bl-
emitted temperature? owing out air.
from
indoor ● Heating mode is turned on just ● In order to prevent blowing
unit now? out cold air, indoor unit will be
started after delaying for sev-
eral minutes, which is a nor-
mal phenomenon.

20
Malfunction analysis
Phenomenon Check items Solution

● Power failure? ● Wait until power recovery.


● Is plug loose? ● Reinsert the plug.
● Air switch trips off or fuse is ● Ask professional to replace
burnt out? air switch or fuse.
Air condit- ● Wiring has malfunction? ● Ask professional to replace it.
ioner can’t
operate ● Unit has restarted immediately
● Wait for 3min, and then turn
after stopping operation?
on the unit again.

● Whether the function setting


for remote controller is ● Reset the function.
correct?

● Because indoor air is cooled


Mist is em-
rapidly. After a while, indoor
itted from ● Indoor temperature and hum-
temperature and humidity will
indoor unit’s idity is high?
be decrease and mist will
air outlet
disappear.

● Temperature can’t be adju-


sted under auto mode.
● Unit is operating under auto
Please switch the operation
Set temper- mode?
mode if you need to adjust
ature can’t temperature.
be adjusted
● Your required temperature
● Set temperature range:
exceeds the set temperature
16℃ ~30℃ .
range?

● Wait until the voltage


● Voltage is too low?
resumes normal.
Cooling ● Filter is dirty?
(heating)
effect is ● Set temperature is in proper ● Adjust temperature to proper
not good. range? range.

● Door and window are open? ● Close door and window.

21
Malfunction analysis
Phenomenon Check items Solution

● Whether there’s odour source, ● Eliminate the odour source.


Odours are
such as furniture and cigarette,
emitted
etc.

Air conditio-
● Whether there’s interference, ● Disconnect power, put back
ner operates
such as thunder, wireless power, and then turn on the
abnormally
devices, etc. unit again.
suddenly

● During defrosting under he-


Outdoor
ating mode, it may generate
unit has ● Heating mode is turned on?
vapor, which is a normal
vapor
phenomenon.

● The noise is the sound of


“Water
● Air conditioner is turned on or
turned off just now? the unit, which is a normal
noise
phenomenon.

● This is the sound of friction


● Air conditioner is turned on or caused by expansion and/or
Cracking
turned off just now? contraction of panel or other
noise
parts due to the change of
temperature.

22
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will

ation of error code.

Error code Troubleshooting


It can be eliminated after restarting the unit. If not, please
E5
It can be eliminated after restarting the unit. If not, please
U8
It can be eliminated after restarting the unit. If not, please
H6

It can be eliminated after restarting the unit. If not, please


H3
C5
F1
F2
F4
F0
E1 It can be eliminated after restarting the unit. If not, please

service.
WARNING
■ When below phenomenon occurs, please turn off air conditioner and discon-

for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.

■ If the air conditioner operates under abnormal conditions, it may cause

23
Installation dimension diagram

Space to the ceiling

At least 15cm
Space to the wall
At least 15cm
At least 15cm
Space to the wall

cm

At least 250cm
3 00
st n
lea uc
tio
At tr
obs
o the
et
ac
Sp
Space to the obstruction

the
to n
At least 50cm

e
ac ctio
Sp stru
ob st
lea
At cm
30

At least 30cm
Space to th
e wall

At least 50cm
n
c tio m
tru 0c Space to the
ob
s 20
st
he t le
a obstruction
tot A
a ce
Sp
Drainage pipe

24
Safety precautions for installing and relocating the unit
To ensure safety, please be mindful of the following precautions.
Warning
When installing or relocating the unit, be sure to keep the refrigerant
circuit free from air or substances other than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause
system pressure rise or compressor rupture, resulting in injury.
When installing or moving this unit, do not charge the refrigerant which
is not comply with that on the nameplate or unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical
malfunction or even series safety accident.
When refrigerant needs to be recovered during relocating or repairing the
unit, be sure that the unit is running in cooling mode.Then, fully close the
valve at high pressure side (liquid valve).About 30-40 seconds later, fully
close the valve at low pressure side (gas valve), immediately stop the unit
and disconnect power. Please note that the time for refrigerant recovery
should not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in and cause
pressure rise or compressor rupture, resulting in injury.
During refrigerant recovery, make sure that liquid valve and gas valve are
fully closed and power is disconnected before detaching the connection pipe.
If compressor starts running when stop valve is open and connection pipe is not
yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury.
When installing the unit, make sure that connection pipe is securely
connected before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is not
yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury.
Prohibit installing the unit at the place where there may be leaked corrosive
gas or flammable gas.
If there leaked gas around the unit, it may cause explosion and other accidents.
Do not use extension cords for electrical connections. If the electric wire
is not long enough, please contact a local service center authorized
and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
Use the specified types of wires for electrical connections between the
indoor and outdoor units. Firmly clamp the wires so that their terminals
receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure
wire terminals may cause electric shock or fire.

25
Tools for installation
1 Level meter 2 Screw driver 3 Impact drill
4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter 9 Leakage detector
10 Vacuum pump 11 Pressure meter 12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
● Please contact the local agent for installation.

Selection of installation location


Basic requirement Indoor unit
Installing the unit in the following pla- 1. There should be no obstruction near air
ces maycause malfunction. If it is un- inlet and air outlet.
avoidable, please consult the local 2. Select a location where the condensat-
dealer: ion water can be dispersed easily and
1.The place with strong heat sources, won't affect other people.
, 3. Select a location which is convenient to
connect the outdoor unit and near the
or volatile objects spread in the air.
power socket.
2.The place with high-frequency 4. Select a location which is out of reach
devices (such as welding machine, for children.
medical equipment). 5. The location should be able to withstand
3.The place near coast area. the weight of indoor unit and won't incr-
4.The place with oil or fumes in the air. ease noise and vibration.
5.The place with sulfureted gas. 6. The appliance must be installed 2.5m
6.Other places with special circums-
tances. 7. Don't install the indoor unit right above
7.The appliance shall not be install- the electric appliance.
ed in the laundry 8. Please try your best to keep way from
fluorescent lamp.
Outdoor unit

will not affect neighborhood.


2. The location should be well ventilated and dry, in which the outdoor unit
won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.
26
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.

air switch.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety. For models with a power plug, make sure the plug is
within reach after installation.

7. If the supply cord is damaged, it must be replaced by the manufacturer, its

8. The temperature of refrigerant circuit will be high, please keep the interconnec-
tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
10. Appliance shall be installed, operated and stored in a room with a floor area
larger than Xm2 . (Please refer to table "a" in section of " Safety Operation of
Inflammable Refrigerant" for Space X.)
Please notice that the unit is filled with flammable gas R32. Inappropriate
treatment of the unit involves the risk of severe damages of people and
material. Details to this refrigerant are found in chapter “refrigerant”.
Grounding requirement

grounding with specialized grounding device by a professional. Please make


sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in

6. Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
Air-conditioner Air switch capacity
09K 10A
12K 16A
15/18/24K 25A
27
Installation of indoor unit
Step one: choosing installation location
rm it with the client.

Step two: install wall-mounting frame


1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the

plastic expansion particles in the holes.


3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and

Step three: open piping hole


1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.

QC: QD:
Wall Wall Wall Wall
Mark in the middle of it Level meter Mark in the middle of it Level meter
Space Space Space Space
to the to the to the to the
wall wall wall wall
above above above above
150mm 150mm 150mm 150mm

Left Right Left Right


Φ55mm Φ55mm Φ55mm Φ55mm
Rear piping hole Rear piping hole Rear piping hole Rear piping hole

QE:
Wall Wall
Mark in the middle of it Level meter
Space Space
to the to the
wall wall
above above
150mm 150mm

Left Right
Φ55/70mm Φ55/70mm
Rear piping hole Rear piping hole

2. Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe
position.In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.

28
Installation of indoor unit

Note: Indoor outdoor


● Pay attention to dust prevention and
take relevant safety measures when
opening the hole.
● The plastic expansion particles are Φ55/
not provided and should be bought 5-10 Φ70
locally.

Step four: outlet pipe


1. The pipe can be led out in the 2. When select leading out the pipe
direction of right, rear right, left or from left or right, please cut off the
rear left. corresponding hole on the bottom
case.
left right

left rear left cut off


rear right the hole
right

1. Aim the pipe joint at the corresponding


bellmouth.
pipe joint union nut pipe
2. Pretightening the union nut with hand.

3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.

29
Installation of indoor unit
open-end Hex nut diameter Tightening torque (N.m)
wrench Φ6 15~20
union nut Φ 9.52 30~40
Φ 12 45~55
torque wrench pipe Φ 16 60~65
Φ 19 70~75
indoor pipe
4. Wrap the indoor pipe and joint of con-
nection pipe with insulating pipe, and
then wrap it with tape. insulating pipe

Step six: install drain hose


1. Connect the drain hose to the outlet pipe of
indoor unit.
drain hose
outlet pipe
2. Bind the joint with tape.
outlet drain hose
pipe
tape

Note: drain hose


● Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
● The plastic expansion particles are
insulating pipe
not provided.

Step seven: connect wire of indoor unit


screw
panel

1. Open the panel, remove the screw


on the wiring cover and then take
down the cover.

wiring cover

30
Installation of indoor unit

2. Make the power connection wire go cable-cross


through the cable-cross hole at the back hole
of indoor unit and then pull it out from
the front side.
power connection
wire

3. Remove the wire clip; connect the power


connection wire to the wiring terminal
according to the color; tighten the screw

with wire clip.

09 12 15 18K : 24K :

N(1) 2 N(1) 2 3
yellow- blue black brown yellow-
blue black green green

Outdoor unit connection Outdoor unit connection

4. Put wiring cover back and then tighten the screw.


5. Close the panel.
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.

for a new one. Avoid extending the wire by yourself.

installation.
● For the air conditioner without plug, an circuit break must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.

31
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power connection pipe drain hose
band
cord and drain hose with the band.
indoor unit
indoor and
outdoor power cord
gas
pipe

indoor power cord

band
liquid pipe 3. Bind them evenly.
drain hose 4. The liquid pipe and gas pipe should
be bound separately at the end.
2. Reserve a certain length of drain
hose and power cord for installation Note:
when binding them. When binding to ● The power cord and control wire
a certain degree, separate the indoor can't be crossed or winding.
power and then separate the drain ● The drain hose should be bound
hose. at the bottom.

Step nine: hang the indoor unit


1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
indoor outdoor upper hook

wall pipe
sealing gum

lower hook of
wall-mounting frame

Note:
● Do not bend the drain hose too excessively in order to prevent blocking.

32
Installation of outdoor unit

(select it according to the actual installation situation)


1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.

Note:

installing the outdoor unit.


● Make sure the support can withstand at least
four times of the unit weight.
● The outdoor unit should be installed at least

joint.
● For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W at least 3cm above the floor
~16000W, 10 expansion screws are needed.

Step two: install drain joint


(Only for cooling and heating 1. Place the outdoor unit on the
unit) support.
1. Connect the outdoor drain joint into 2. Fix the foot holes of outdoor unit
the hole on the chassis, as shown in with bolts.
the picture below. foot holes
2. Connect the drain hose into the drain
vent.

drain vent chassis foot holes


outdoor drain joint
Drain hose

33
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right han- 3. Pretightening the union nut with
dle of outdoor unit and then remove hand.
the handle.
pipe joint
screw

union nut
handle

2. Remove the screw cap of valve and 4. Tighten the union nut with torque
aim the pipe joint at the bellmouth of wrench by referring to the sheet
pipe. below.
liquid pipe Hex nut diameter Tightening torque
(N.m)
liquid gas pipe Φ6 15~20
valve Φ 9.52 30~40
Φ 12 45~55
gas valve Φ 16 60~65
Φ 19 70~75

1. Remove the wire clip; connect the power connection wire and signal control
wire (only for cooling and heating unit) to the wiring terminal according to the

09 12 15K : 18K :
N(1) 2 N(1) 2
yellow- yellow-
blue black
green blue black
(brown) green

Indoor unit connection Indoor unit connection

24K:
N(1) 2 3
blue black brown yellow-
green

Indoor unit connection

34
Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:

● Never cut the power connection wire to prolong or shorten the distance.

Step six: neaten the pipes


1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10cm.
wall
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the U-shaped curve
room.
drain hose

Note:
● The through-wal height of drain hose ● Slant the drain hose slightly dow-
shouldn't be higher than the outlet nwards. The drain hose can't be
pipe hole of indoor unit.
the drain hose
can't raise
upwards.

The drain hose can't be fluctuant


● The water outlet can't be placed
in water in order to drain smoothly.

The drain hose


can't be fluctuant
The water
outlet can't be
fluctuant
The water outlet
can't be placed
in water

35
Vacuum pumping
Use vacuum pump

1. Remove the valve caps on


the liquid valve and gas liquid valve piezometer Lo Hi
valve and the nut of refri-
gerant charging vent. gas valve
2. Connect the charging hose refrigerant valve cap
of piezometer to the refri- charging vent
gerant charging vent of gas nut of refrigerant
valve and then connect the charging vent
other charging hose to the
vacuum pump. vacuum pump
3. Open the piezometer com-
pletely and operate for inner hexagon
10-15min to check if the spanner
pressure of piezometer re-
mains in -0.1MPa. close
4. Close the vacuum pump
open
and maintain this status for
1-2min to check if the pres-
sure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
7. Reinstall the handle.

Leakage detection
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.

36
Check after installation

Items to be checked Possible malfunction


The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test? (heating) capacity.
It may cause condensation and water
dripping.
It may cause condensation and water
Is water drained well?
dripping.
Is the voltage of power supply accord-
ing to the voltage marked on the It may cause malfunction or damaging
nameplate? the parts.

Is electric wiring and pipeline installed It may cause malfunction or damaging


correctly? the parts.
Is the unit grounded securely? It may cause electric leakage.
Does the power cord follow the speci- It may cause malfunction or damaging
the parts.
Is there any obstruction in the air inlet
and outlet? (heating) capacity.
The dust and sundries caused during It may cause malfunction or damaging
installation are removed? the parts.
The gas valve and liquid valve of
connection pipe are open completely? (heating) capacity.
Is the inlet and outlet of piping hole It may cause insufficient cooling
been covered? (heating) capacity or waster eletricity.

Test operation
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃ , the air conditioner can’t
start cooling.
37
Configuration of connection pipe
1. Standard length of connection pipe
● 5m、7.5m、8m
2. Min length of connection pipe
For the unit with standard connection pipe of 5m, there is no limitation for the
min length of connection pipe. For the unit with standard connection pipe of
7.5m and 8m, the min length of connection pipe is 3m.
3. Max length of connection pipe
Sheet 1 Max length of connection pipe Unit: m

Max length of Max length of


capacity capacity
connection pipe connection pipe

5000Btu/h 24000Btu/h
15 25
(1465W) (7032W)

7000Btu/h 28000Btu/h
15 30
(2051W) (8204W)

9000Btu/h 36000Btu/h
15 30
(2637W) (10548W)

12000Btu/h 42000Btu/h
20 30
(3516W) (12306W)

18000Btu/h 48000Btu/h
25 30
(5274W) (14064W)

4. The calculation method of additional refrigerant oil and refrigerant charging amount
after prolonging connection pipe
After the length of connection pipe is prolonged for 10m at the basis of standard
length, you should add 5ml of refrigerant oil for each additional 5m of connection
pipe.
The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
(1) Additional refrigerant charging amount= prolonged length of liquid pipe × additional
refrigerant charging amount per meter
(2) Basing on the length of standard pipe, add refrigerant according to the
requirement as shown in the table. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See Sheet 2.

38
Configuration of connection pipe

Sheet 2. Additional refrigerant charging amount for R32

Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle


Cooling only, Cooling only cooling and
Liquid pipe Gas pipe cooling and heating heating
(g / m)
(g / m) (g / m)

Ф6 Ф9.5 or Ф12 16 12 16

Ф6 or Ф9.5 Ф16 or Ф19 40 12 40

Ф12 Ф19 or Ф22.2 80 24 96

Ф16 Ф25.4 or Ф31.8 136 48 96


_
Ф19 200 200 200
_
Ф22.2 280 280 280

Note: The additional refrigerant charging amount in Sheet 2 is recommended


value, not compulsory.

39
Safety operation of flammable refrigerant
Qualification requirement for installation and maintenance man
All the work men who are engaging in the refrigeration system should bear the
valid certification awarded by the authoritative organization and the qualification
for dealing with the refrigeration system recognized by this industry. If it needs
other technician to maintain and repair the appliance, they should be supervised
by the person who bears the qualification for using the flammable refrigerant.
It can only be repaired by the method suggested by the equipment’s manufacturer.
Installation notes
The air conditioner is not allowed to use in a room that has running fire (such as fire
source, working coal gas ware, operating heater).
It is not allowed to drill hole or burn the connection pipe.
The air conditioner must be installed in a room that is larger than the minimum room
area. The minimum room area is shown on the nameplate or following table a.
Leak test is a must after installation.
table a - Minimum room area ( m 2 )
Charge amount (kg) ≤1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2 2.3 2.4 2.5

floor location / 14.5 16.8 19.3 22 24.8 27.8 31 34.3 37.8 41.5 45.4 49.4 53.6
Minimum
room window mounted / 5.2 6.1 7 7.9 8.9 10 11.2 12.4 13.6 15 16.3 17.8 19.3
area( m 2 )
wall mounted / 1.6 1.9 2.1 2.4 2.8 3.1 3.4 3.8 4.2 4.6 5 5.5 6

ceiling mounted / 1.1 1.3 1.4 1.6 1.8 2.1 2.3 2.6 2.8 3.1 3.4 3.7 4

Maintenance notes
Check whether the maintenance area or the room area meet the requirement of the
nameplate.
- It’s only allowed to be operated in the rooms that meet the requirement of the
nameplate.
Check whether the maintenance area is well-ventilated.
- The continuous ventilation status should be kept during the operation process.
Check whether there is fire source or potential fire source in the maintenance area.
- The naked flame is prohibited in the maintenance area; and the “no smoking”
warning board should be hanged.
Check whether the appliance mark is in good condition.
- Replace the vague or damaged warning mark.
Welding
If you should cut or weld the refrigerant system pipes in the process of maintaining,
please follow the steps as below:
40
Safety operation of flammable refrigerant
a. Shut down the unit and cut power supply
b. Eliminate the refrigerant
c. Vacuuming
d. Clean it with N2 gas
e. Cutting or welding
f. Carry back to the service spot for welding
The refrigerant should be recycled into the specialized storage tank.
Make sure that there isn’t any naked flame near the outlet of the vacuum pump
and it’s well-ventilated.
Filling the refrigerant
Use the refrigerant filling appliances specialized for R32. Make sure that different
kinds of refrigerant won’t contaminate with each other.
The refrigerant tank should be kept upright at the time of filling refrigerant.
Stick the label on the system after filling is finished (or haven’t finished).
Don’t overfilling.
After filling is finished, please do the leakage detection before test running; another
time of leak detection should be done when it’s removed.
Safety instructions for transportation and storage
Please use the flammable gas detector to check before unload and open the container.
No fire source and smoking.
According to the local rules and laws.

41
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe E: Expand the port
● Expand the port with expander.
the distance of indoor unit and
outdoor unit. hard
mold
● Cut the required pipe with pipe cutter. expander
pipe

pipe
pipe cutter

leaning uneven burr


Note:
● "A" is different according to the
diameter, please refer to the sheet
below:

Outer diameter A(mm)


B: Remove the burrs (mm) Max Min
● Remove the burrs with shaper and
prevent the burrs from getting into Φ6 - 6.35(1/4") 1.3 0.7
the pipe. Φ9.52(3/8") 1.6 1.0
pipe
shaper Φ12-12.7(1/2") 1.8 1.0
Φ15.8-16(5/8") 2.4 2.2
downwards
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the
C: Put on suitable insulating pipe port again according to the steps
D: Put on the union nut above.
● Remove the union nut on the indoor
smooth surface
connection pipe and outdoor valve;
install the union nut on the pipe.
improper expanding
union pipe

leaning damaged crack uneven


surface thickness
pipe the length is equal

42
Two (2) free preventive maintenance service (Labour only) will be provided to the customer during first year warranty period.
To avail these free services customer has to register the call at the call center number 1800 209 5511. After expiry of 12
(twelve) months from date of purchase company is not liable for any free service.
13. Any Damage due to rodent attacks or environment conditions like electrical surges or low voltages will be repaired on chargeable
basis.

You might also like