The Refrigerant
To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R32, which is specially cleaned.
The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion
under certain conditions. But the flammability of the refrigerant is very low. It can
be ignited only by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.
WARNING:
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacture. Should repair be necessary, contact your nea-
rest authorized Service Centre. Any repairs carried out by unqualified personnel
may be dangerous. The appliance shall be stored in a room without continuously
operating ignition sources. (for example: open flames, an operating gas appliance
or an operating electric heater.) Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a floor area larger
than X m 2. (Please refer to table "a" in section of " Safety Operation of Inflammable
Refrigerant" for Space X.)
Appliance filled with flammable gas R32. For repairs, strictly follow manufacturer’s
instructions only. Be aware that refrigrants not contain odour. Read specialist’s
manual.
1
Precautions
WARNING
2
Precautions
WARNING
3
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note the following table. Air switch should be included
magnet buckle and heating buckle function, it can protect
the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the
requirement of air conditioner. Unstable power supply or
incorrect wiring or malfunction. Please install proper power
supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.
4
Precautions
WARNING
5
Precautions
WARNING
For the air conditioner with plug, the plug should be
reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants.If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall
Please notice that the unit is filled with flammable gas
R32. Inappropriate treatment of the unit involves the
risk of severe damages of people and material. Details
to this refrigerant are found in chapter “refrigerant”.
Check whether the maintenance area or the room area
meet the requirement of the nameplate.
- It’s only allowed to be operated in the rooms that meet
the requirement of the nameplate.
Check whether the maintenance area is well-ventilated.
- The continuous ventilation status should be kept
during the operation process.
Check whether there is fire source or potential fire source
in the maintenance area.
- The naked flame is prohibited in the maintenance area;
and the “no smoking” warning board should be hanged.
Check whether the appliance mark is in good condition.
- Replace the vague or damaged warning mark.
Please use the flammable gas detector to check before
unload and open the container.
No fire source and smoking.
According to the local rules and laws.
6
Precautions
WARNING
NOTICE:
● The operating temperature range (outdoor temperature) for cooling only unit is
18℃ ~ 48℃ ; for heat pump unit is -7℃ ~ 48℃ .
7
Parts Name
Indoor Unit
air inlet
panel
aux.button
horizontal louver
air outlet
AIR HEALTH X-FAN
HUMIDITY
FILTER
TURBO
HOUR
ON/OFF
ON/OFF MODE
FAN
Outdoor Unit
air inlet
Connection wire
air outlet
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
8
Parts name
Display
temp.
indicator Power LED color indicator:
receiver Green-status-ON.
window Red -status-OFF.
Red-R-Heat Mode- R
(only for heating model)
Green-G-Dry Mode- G
For some model:
For some model: Power indicatior
display
temp. temp.
indicator indicator
Power LED color indicator: display
receiver Green-status-ON.
window Red -status-OFF.
receiver
Mode LED color indicator: window
W R O
White-W-Cool Mode-
W
Red-R-Heat Mode- R
(only for heating model)
Orange-O-Dry Mode- O
Display content or position may be different from above graphics, please refer to actual
products.
9
Buttons on remote controller
FAN AUTO 1 ON/OFF button
OPER
AIR HEALTH X-FAN
HUMIDITY
2 MODE button
FILTER 3 +/- button
TURBO
HOUR 4 FAN button
ON/OFF
5 button
1 2 6 button
ON/OFF MODE
10
Introduction for buttons on remote controller
Note:
● This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model doesn't have, if press
the corresponding button on the remote controller that the unit will keep the
original running status.
● After putting through power, air conditioner will give out a sound and operation
indicator " " is ON (red indicator, the colour is different for different models).
You can operate the air conditioner through the remote controller.
● At ON status, after each pressing button on remote controller, the signal icon " "
● After selecting auto mode, air conditioner will operate automatically according to
ambient temperature. Set temperature can’t be adjusted and also can’t be displa-
yed. Press"FAN" button can adjust fan speed. Press " " button can adjust swing angle.
● After selecting cool mode, air conditioner operates under cool mode. Cool indicator
" " on indoor unit is ON (This indicator is not available for some models). You can
press "+" or "-" button to adjust set temperature. Press "FAN" button can adjust fan
speed. Press " " button can adjust swing angle.
● After selecting dry mode, air conditioner operates under dry mode at low speed.
Dry indicator " " on indoor unit is ON (This indicator is not available for some
models). Under dry mode, fan speed can’t be ad justed. Press " " button to adjust
swing angle.
● After selecting fan mode, air conditioner operates only under fan mode, All mode
indicators on indoor unit is OFF. Operation indicator is ON.(This indicator is not available for
some models). Press "FAN" button can adjust fan speed. Press " " button to adjust swing angle.
● After selecting heat mode, air conditioner operates under heat mode. Heat indicator
" " on indoor unit is ON(This indicator is not available for some models).
You can press "+" or "-" button to adjust set temperature.
Press "FAN" button to adjust fan speed. Press " " button to adjust swing angle.
(Cooling only unit can’t receive the signal for heating mode.)
11
Introduction for buttons on remote controller
Note:
For preventing cold wind, after starting up heating mode, indoor fan will blow fan
afterdelaying 1-5min. (Details time is decided by indoor ambient temperature)
Temperature setting range on remote controller: 16℃ -30℃ . Fan speed setting
range: auto, low speed, medium speed and high speed.
4 FAN button
Pressing this button can set fan speed circularly as: auto (AUTO), low( ),
medium( ), high( ).
Auto
Note:
● Under AUTO Speed,IDU fan motor will adjust the fan speed (high, medium or
low speed) according to ambient temperature.
● Fan speed under dry mode is low speed.
5 button
● Press this button to start or stop up & down swing function.The remote controller
defaults to simple swing condition.
● Press + button and button at the same time at unit OFF to switch between
simple swing and static swing; blinks for 2 seconds.
● In static swing condition, pressing button, the swing angle of up & down louver
changes as below:
no display
(horizontal louvers stops
at current position)
● If the unit is turned off during swing operation,the louver will stop at present
position.
12
Introduction for buttons on remote controller
Note:
When selecting " " with remote controller, it’s auto swing. Horizontal louver of air
conditioner will swing up&down automatically at the maximum angle.
When selecting " 、 、 、 、
swing. Horizontal louver of air conditioner will stop at that position as shown by the
icon to swing.
6 button
● Press this button to start or stop left & right swing function. The remote controller
defaults to simple swing condition.
● Press + button and button at the same time at unit OFF to switch between
simple swing and static swing; blinks for 2 seconds.
● In static swing condition, pressing button, the swing angle of left & right louver
changes as below:
no display
(horizontal louvers stops (swing angle is dis-
at current position) played dynamically)
● If the unit is turned off during swing operation,the louver will stop at present
position.
● When selecting " " with remote controller, it’s auto swing. Horizontal louver of
air conditioner will swing left&right automatically at the maximum angle.
● When selecting " 、 、 、 、 "
position swing. Horizontal louver of air conditioner will stop at that position as
shown by the icon to swing.
● When selecting " ", it’s the circulating swing. Horizontal louver of
(swing angle is displayed dynamically)
air conditioner will swing circularly according to the angle as shown by the icon.
Note: There is no this function for the units. If press this key, the main unit will
click, but it also runs under original status.
7 HEALTH SAVE button
HEALTH FUNCTION:
After pressing HEALTH button, remote controller will switch circularly as below:
"HEALTH"→"AIR"→"AIR HEALTH"→"no display"
● When selecting "HEALTH" by remote controller, HEALTH function will be started up.
● When selecting "AIR" by remote controller, AIR function will be started up.
● When selecting "AIT HEALTH", AIR and HEALTH function will be started up.
● When there’s no display on remote controller, AIR and HEALTH function will be
turned off.
● AIR function is applicable for some models.
● HEALTH function is applicable for some models.
13
Introduction for buttons on remote controller
SAVE function:
Under cool mode, press SAVE button and the unit will operate under SAVE mode.
Dual-8nixie tube on remote controller displays "SE". Air conditioner will operate at
auto speed. Set temperature can’t be adjusted. Press SAVE button again to exit
SAVE mode. Air conditioner turn back to original set speed and set temperature.
8 X-FAN button
After pressing this button under cooling or dry mode, remote controller displays the
character of "X-FAN" and X-FAN function is started up. Press this button again to
cancel X-FAN function. The character of "X-FAN" will disappear.
Note:
● After starting up X-FAN function, when turning off the unit, indoor fan will continue
to operate for a while at low speed to dry the residual water inside the indoor unit.
● When the unit operates under X-FAN mode, press "X-FAN" button can turn off
X-FAN function. Indoor fan stops operation immediately.
9 TEMP button
Press this button can see indoor set temperature, indoor ambient temperature or
outdoor ambient temperature on indoor unit’s display. Temperature is set circularly
by remote controller as below:
no display
10 TIMER button
● At ON status, press this button once can set TIMER OFF. The character of HOUR
TIMER
ON. After each pressing of "+" or "-" button, time will increase or decrease half an
14
Introduction for buttons on remote controller
hour. When holding "+" or "-" button, 2s later, the time will change quickly until to
Cancel TIMER OFF: Press "TIMER" button again under TIMER OFF status.
● At OFF status, press this button once can set TIMER ON. Please refer to TIMER
off for detailed operation.
Cancel TIMER ON: Press "TIMER" button again under TIMER ON status.
Note:
● Time setting range: 0.5-24 hours.
● Time interval between two operations can’t exceed 5s. Otherwise, remote
controller will exit the setting status automatically.
11 TURBO button
When pressing this button under cooling or heating mode, air conditioner will enter
into quick cooling or quick heating mode. The character of "TURBO" is displayed
on remote controller. Press this button again to exit turbo function and the character
of "TURBO" will be disappeared on remote controller.
12 SLEEP button
Press this button under cooling, heating mode can start up sleep function.
" " icon will be displayed on remote controller. Press this button again to cancel
sleep function. " "icon on remote controller will be displayed.
13 LIGHT button
Press this button can turn off the light for indoor unit’s display. " " icon on remote
controller will disappear. Press this button again to turn on the light for indoor unit’s
display. " " icon on remote controller will be displayed.
15
Operation guide
1. After putting through the power, press " ON/OFF " button on remote controller to
turn on the air conditioner.
2. Press " MODE " button to select your required mode: AUTO, COOL, DRY, FAN,
HEAT.
3. Press "+" or "-" button to set your required temperature. (Temperature can’t be
adjusted under auto mode).
4. Press " FAN " button to set your required fan speed: auto, low, medium and
high speed.
5. Press " " button to select fan blowing angle.
NOTICE
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
● The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
16
Emergency operation
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
panel
aux. button
WARNING:
Use insulated object to press the auto button
■ Do not wash the air conditioner with water to avoid electric shock.
17
Clean and maintenance
Open panel
1 Pull out the panel to a certain
3 ● Use dust catcher or water to
4
panel cover tightly.
WARNING
18
Clean and maintenance
19
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
20
Malfunction analysis
Phenomenon Check items Solution
21
Malfunction analysis
Phenomenon Check items Solution
Air conditio-
● Whether there’s interference, ● Disconnect power, put back
ner operates
such as thunder, wireless power, and then turn on the
abnormally
devices, etc. unit again.
suddenly
22
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will
service.
WARNING
■ When below phenomenon occurs, please turn off air conditioner and discon-
for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
23
Installation dimension diagram
At least 15cm
Space to the wall
At least 15cm
At least 15cm
Space to the wall
cm
At least 250cm
3 00
st n
lea uc
tio
At tr
obs
o the
et
ac
Sp
Space to the obstruction
the
to n
At least 50cm
e
ac ctio
Sp stru
ob st
lea
At cm
30
At least 30cm
Space to th
e wall
At least 50cm
n
c tio m
tru 0c Space to the
ob
s 20
st
he t le
a obstruction
tot A
a ce
Sp
Drainage pipe
24
Safety precautions for installing and relocating the unit
To ensure safety, please be mindful of the following precautions.
Warning
When installing or relocating the unit, be sure to keep the refrigerant
circuit free from air or substances other than the specified refrigerant.
Any presence of air or other foreign substance in the refrigerant circuit will cause
system pressure rise or compressor rupture, resulting in injury.
When installing or moving this unit, do not charge the refrigerant which
is not comply with that on the nameplate or unqualified refrigerant.
Otherwise, it may cause abnormal operation, wrong action, mechanical
malfunction or even series safety accident.
When refrigerant needs to be recovered during relocating or repairing the
unit, be sure that the unit is running in cooling mode.Then, fully close the
valve at high pressure side (liquid valve).About 30-40 seconds later, fully
close the valve at low pressure side (gas valve), immediately stop the unit
and disconnect power. Please note that the time for refrigerant recovery
should not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in and cause
pressure rise or compressor rupture, resulting in injury.
During refrigerant recovery, make sure that liquid valve and gas valve are
fully closed and power is disconnected before detaching the connection pipe.
If compressor starts running when stop valve is open and connection pipe is not
yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury.
When installing the unit, make sure that connection pipe is securely
connected before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is not
yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury.
Prohibit installing the unit at the place where there may be leaked corrosive
gas or flammable gas.
If there leaked gas around the unit, it may cause explosion and other accidents.
Do not use extension cords for electrical connections. If the electric wire
is not long enough, please contact a local service center authorized
and ask for a proper electric wire.
Poor connections may lead to electric shock or fire.
Use the specified types of wires for electrical connections between the
indoor and outdoor units. Firmly clamp the wires so that their terminals
receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure
wire terminals may cause electric shock or fire.
25
Tools for installation
1 Level meter 2 Screw driver 3 Impact drill
4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter 9 Leakage detector
10 Vacuum pump 11 Pressure meter 12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
● Please contact the local agent for installation.
air switch.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety. For models with a power plug, make sure the plug is
within reach after installation.
8. The temperature of refrigerant circuit will be high, please keep the interconnec-
tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
10. Appliance shall be installed, operated and stored in a room with a floor area
larger than Xm2 . (Please refer to table "a" in section of " Safety Operation of
Inflammable Refrigerant" for Space X.)
Please notice that the unit is filled with flammable gas R32. Inappropriate
treatment of the unit involves the risk of severe damages of people and
material. Details to this refrigerant are found in chapter “refrigerant”.
Grounding requirement
6. Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
Air-conditioner Air switch capacity
09K 10A
12K 16A
15/18/24K 25A
27
Installation of indoor unit
Step one: choosing installation location
rm it with the client.
QC: QD:
Wall Wall Wall Wall
Mark in the middle of it Level meter Mark in the middle of it Level meter
Space Space Space Space
to the to the to the to the
wall wall wall wall
above above above above
150mm 150mm 150mm 150mm
QE:
Wall Wall
Mark in the middle of it Level meter
Space Space
to the to the
wall wall
above above
150mm 150mm
Left Right
Φ55/70mm Φ55/70mm
Rear piping hole Rear piping hole
2. Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe
position.In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
28
Installation of indoor unit
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
29
Installation of indoor unit
open-end Hex nut diameter Tightening torque (N.m)
wrench Φ6 15~20
union nut Φ 9.52 30~40
Φ 12 45~55
torque wrench pipe Φ 16 60~65
Φ 19 70~75
indoor pipe
4. Wrap the indoor pipe and joint of con-
nection pipe with insulating pipe, and
then wrap it with tape. insulating pipe
wiring cover
30
Installation of indoor unit
09 12 15 18K : 24K :
N(1) 2 N(1) 2 3
yellow- blue black brown yellow-
blue black green green
installation.
● For the air conditioner without plug, an circuit break must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
31
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power connection pipe drain hose
band
cord and drain hose with the band.
indoor unit
indoor and
outdoor power cord
gas
pipe
band
liquid pipe 3. Bind them evenly.
drain hose 4. The liquid pipe and gas pipe should
be bound separately at the end.
2. Reserve a certain length of drain
hose and power cord for installation Note:
when binding them. When binding to ● The power cord and control wire
a certain degree, separate the indoor can't be crossed or winding.
power and then separate the drain ● The drain hose should be bound
hose. at the bottom.
wall pipe
sealing gum
lower hook of
wall-mounting frame
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
32
Installation of outdoor unit
Note:
joint.
● For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W at least 3cm above the floor
~16000W, 10 expansion screws are needed.
33
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right han- 3. Pretightening the union nut with
dle of outdoor unit and then remove hand.
the handle.
pipe joint
screw
union nut
handle
2. Remove the screw cap of valve and 4. Tighten the union nut with torque
aim the pipe joint at the bellmouth of wrench by referring to the sheet
pipe. below.
liquid pipe Hex nut diameter Tightening torque
(N.m)
liquid gas pipe Φ6 15~20
valve Φ 9.52 30~40
Φ 12 45~55
gas valve Φ 16 60~65
Φ 19 70~75
1. Remove the wire clip; connect the power connection wire and signal control
wire (only for cooling and heating unit) to the wiring terminal according to the
09 12 15K : 18K :
N(1) 2 N(1) 2
yellow- yellow-
blue black
green blue black
(brown) green
24K:
N(1) 2 3
blue black brown yellow-
green
34
Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:
● Never cut the power connection wire to prolong or shorten the distance.
Note:
● The through-wal height of drain hose ● Slant the drain hose slightly dow-
shouldn't be higher than the outlet nwards. The drain hose can't be
pipe hole of indoor unit.
the drain hose
can't raise
upwards.
35
Vacuum pumping
Use vacuum pump
Leakage detection
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
36
Check after installation
Test operation
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃ , the air conditioner can’t
start cooling.
37
Configuration of connection pipe
1. Standard length of connection pipe
● 5m、7.5m、8m
2. Min length of connection pipe
For the unit with standard connection pipe of 5m, there is no limitation for the
min length of connection pipe. For the unit with standard connection pipe of
7.5m and 8m, the min length of connection pipe is 3m.
3. Max length of connection pipe
Sheet 1 Max length of connection pipe Unit: m
5000Btu/h 24000Btu/h
15 25
(1465W) (7032W)
7000Btu/h 28000Btu/h
15 30
(2051W) (8204W)
9000Btu/h 36000Btu/h
15 30
(2637W) (10548W)
12000Btu/h 42000Btu/h
20 30
(3516W) (12306W)
18000Btu/h 48000Btu/h
25 30
(5274W) (14064W)
4. The calculation method of additional refrigerant oil and refrigerant charging amount
after prolonging connection pipe
After the length of connection pipe is prolonged for 10m at the basis of standard
length, you should add 5ml of refrigerant oil for each additional 5m of connection
pipe.
The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
(1) Additional refrigerant charging amount= prolonged length of liquid pipe × additional
refrigerant charging amount per meter
(2) Basing on the length of standard pipe, add refrigerant according to the
requirement as shown in the table. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See Sheet 2.
38
Configuration of connection pipe
Ф6 Ф9.5 or Ф12 16 12 16
39
Safety operation of flammable refrigerant
Qualification requirement for installation and maintenance man
All the work men who are engaging in the refrigeration system should bear the
valid certification awarded by the authoritative organization and the qualification
for dealing with the refrigeration system recognized by this industry. If it needs
other technician to maintain and repair the appliance, they should be supervised
by the person who bears the qualification for using the flammable refrigerant.
It can only be repaired by the method suggested by the equipment’s manufacturer.
Installation notes
The air conditioner is not allowed to use in a room that has running fire (such as fire
source, working coal gas ware, operating heater).
It is not allowed to drill hole or burn the connection pipe.
The air conditioner must be installed in a room that is larger than the minimum room
area. The minimum room area is shown on the nameplate or following table a.
Leak test is a must after installation.
table a - Minimum room area ( m 2 )
Charge amount (kg) ≤1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2 2.3 2.4 2.5
floor location / 14.5 16.8 19.3 22 24.8 27.8 31 34.3 37.8 41.5 45.4 49.4 53.6
Minimum
room window mounted / 5.2 6.1 7 7.9 8.9 10 11.2 12.4 13.6 15 16.3 17.8 19.3
area( m 2 )
wall mounted / 1.6 1.9 2.1 2.4 2.8 3.1 3.4 3.8 4.2 4.6 5 5.5 6
ceiling mounted / 1.1 1.3 1.4 1.6 1.8 2.1 2.3 2.6 2.8 3.1 3.4 3.7 4
Maintenance notes
Check whether the maintenance area or the room area meet the requirement of the
nameplate.
- It’s only allowed to be operated in the rooms that meet the requirement of the
nameplate.
Check whether the maintenance area is well-ventilated.
- The continuous ventilation status should be kept during the operation process.
Check whether there is fire source or potential fire source in the maintenance area.
- The naked flame is prohibited in the maintenance area; and the “no smoking”
warning board should be hanged.
Check whether the appliance mark is in good condition.
- Replace the vague or damaged warning mark.
Welding
If you should cut or weld the refrigerant system pipes in the process of maintaining,
please follow the steps as below:
40
Safety operation of flammable refrigerant
a. Shut down the unit and cut power supply
b. Eliminate the refrigerant
c. Vacuuming
d. Clean it with N2 gas
e. Cutting or welding
f. Carry back to the service spot for welding
The refrigerant should be recycled into the specialized storage tank.
Make sure that there isn’t any naked flame near the outlet of the vacuum pump
and it’s well-ventilated.
Filling the refrigerant
Use the refrigerant filling appliances specialized for R32. Make sure that different
kinds of refrigerant won’t contaminate with each other.
The refrigerant tank should be kept upright at the time of filling refrigerant.
Stick the label on the system after filling is finished (or haven’t finished).
Don’t overfilling.
After filling is finished, please do the leakage detection before test running; another
time of leak detection should be done when it’s removed.
Safety instructions for transportation and storage
Please use the flammable gas detector to check before unload and open the container.
No fire source and smoking.
According to the local rules and laws.
41
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe E: Expand the port
● Expand the port with expander.
the distance of indoor unit and
outdoor unit. hard
mold
● Cut the required pipe with pipe cutter. expander
pipe
pipe
pipe cutter
42
Two (2) free preventive maintenance service (Labour only) will be provided to the customer during first year warranty period.
To avail these free services customer has to register the call at the call center number 1800 209 5511. After expiry of 12
(twelve) months from date of purchase company is not liable for any free service.
13. Any Damage due to rodent attacks or environment conditions like electrical surges or low voltages will be repaired on chargeable
basis.