If you’ve ever asked yourself “why?” about something related to structural steel design or construction, Modern
Steel Construction’s monthly Steel Interchange column is for you! Send your questions or comments to [email protected].
The aspect ratio restriction in AISC Specification Section K3.3a(6) The complete collection of Steel Interchange questions and answers is available online.
is referring to both the branch and the chord. This is clarified Find questions and answers related to just about any topic by using our full-text search
capability. Visit Steel Interchange online at www.modernsteel.com.
in the 2010 AISC Specification (a free download at www.aisc.
org/2010spec). AISC Steel Design Guide No. 24, Hollow Structural Heath Mitchell is director of technical assistance, Erin Criste is staff engineer, technical
assistant and Tom Schlafly is director of research at AISC. Larry Muir and Brad Davis are
Section Connections (www.aisc.org/epubs) also addresses this and consultants to AISC.
does have design examples for HSS moment connections.
The Commentary to Chapter K explains that the limits of Steel Interchange is a forum to exchange useful and practical professional ideas and
information on all phases of steel building and bridge construction. Opinions and
applicability generally represent the parameter range over which suggestions are welcome on any subject covered in this magazine.
the design provisions have been verified in experiments. They The opinions expressed in Steel Interchange do not necessarily represent an official
position of the American Institute of Steel Construction and have not been reviewed. It is
have also been set to eliminate the occurrence of certain failure recognized that the design of structures is within the scope and expertise of a competent
modes for particular connection types. They set the scope of licensed structural engineer, architect or other licensed professional for the application of
principles to a particular structure.
connections for which the AISC Specification is intended to be
If you have a question or problem that your fellow readers might help you solve, please
used. Designs outside of these limits are allowed, but because they forward it to us. At the same time, feel free to respond to any of the questions that you
are outside of the scope of the specification, the design needs to have read here. Contact Steel Interchange via AISC’s Steel Solutions Center: