GTD-2000Ex: Image DIMENSION (Unit: MM)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Fixed type Flammable Gas Detector GAS & FLAME DETECTION SYSTEM

36 | 37

GTD-2000Ex Smart Diffusion Flammable Gas Detector


| Continuous detection of flammable gases in explosion hazardous area with flame proof structure | Self diagnosis function with built-in Microprocessor | Detection
gas from low to high concentration owing to various detection principle | Stable quality and proved detection principle for service life | Built-in back light LCD or
OLED display | Easy Configuration of monitoring by HART communication | Auto calibration and program setting with a magnet bar | 4-20mA (Current source or
Sink) output signal | With the alarm unit - Normal : Green LED - Alarm : Red LED, Buzzer(95 dB) - Trouble : Yellow LED | Calibration and maintenance by one-man |

IMAGE DIMENSION (Unit : mm)


136.0
136.0
120.0
120.0
110.0
110.0

63.0
63.0
166.0
2-Ø7

166.0
2-Ø7

103.0
103.0
ACCESSORIES
110.0
110.0
Ø105.0
Ø105.0
110.0

Cable Gland GTL-100 Rain cover


110.0
56.0
56.0

35.0
35.0
25.0
25.0

8.08.0
Splash guard Collecting-cone HART Module 120.0
120.0
136.0
136.0

SPECIFICATION
※ Specifications are subject to be changed without prior notice.
SMART & LOCAL DISPLAY TYPE FLAMMABLE GAS DETECTOR
Model GTD-2000Ex
Measuring gas Flammable gases (LNG, LPG, H2, Methane, Buthane & etc)
Measuring type Diffusion type
Measuring method Catalytic cell Hot wire semiconductor cell Thermal conductivity cell
Measuring range 0~100% LEL 0~2000ppm 0~100% Vol
Response time < 15sec / 90% scale
Accuracy ±3% / Full scale
Parameter control Non intrusive control with a Magnet bar (calibration, maintenance)
Operation mode display 1-LED (Power)
Measuring value display LCD display (Built in back light 2-Line, 8 characters) / OLED Type (Option)
Analog : Measuring signal : 4-20mA DC Calibration signal : 3mA DC Fault signal : 0mA DC
Output signal
Digital : 2mA (HART 7, HART Device Description Language available, Option)
Material Housing : ALDC, SUS316(Option) / Sensor : SUS316
Conduit connection Standard : PF 3/4" Option : NPT 1/2", NPT3/4", M20 x 1.5P, M25 x 1.5P
Mounting type 2" Pole mount, Wall mount, Duct mount
Operating temperature -40℃ ~ +80℃
Operating humidity 5 ~ 99%.RH (non-condensing)
Dimensions 136(W) x 166(H) x 110(D)mm
Weight 1.5kg

CERTIFICATION
KCs Ex tD A21 IP66 T85℃, Ex d IIC T6, T5, T4 ATEX / IECEx Ex db IIC Gb T6, T5, T4
NEPSI Ex d llC T5 Gb UL Class I, Division 1, Groups A.B.C.D
CE / KC / MED / KR / ABS / BV / DNV / HART / SIL2 / PESO / TRCU ex / CPA Refer to website