W1 W2 H1 H2 H3 D
* without fan
Unrestricted © Siemens AG 2015 All rights reserved.
** with integrated line filter
Page 4 20.03.2015 BJJ Author / Department
Communication
Communication
Integrated communication interface for USS and MODBUS RTU,
additional modules are not required.
Setpoints can also be specified via the analog input
Integrated communication macros
The automation system can be conveniently set up via the
standardized libraries in the PLC
Hibernation mode
Robustness Integrated energy saving functions for stand-by.
Comprehensive options…
V20 BOP Line Braking resistor, Braking resistor,,
(Basic Operator Panel) reactor small large
(FSA, FSB, FSC) (FSD, FSE)
Line
filter
BOP (Basic Operator Panel)
interface
SD/MMC
Memory card
Shield Braking
connection kit module
(FSA, FSB, FSC)
Output Braking
reactor
ECO Mode
Machine setting according to the relevant
application and adjustment of the current flow to
save energy.
DC coupling
Re-use regenerative energy across multiple
inverters.
Hibernation Mode
Integrated energy saving functions for standby
mode.
Basic functions
Communication
• Setpoint selection, setpoint channel
Optionally: • Actuation and feedback (PROFIdrive profile)
• RS485 with USS protocol, Modbus/RTU • Different motor and control data sets
• Profinet • Macros for quick configuration
• PROFIBUS DP • Integrated technology controller (PID)
• CANopen • Brakes (pending motor holding brake, DC,
integrated chopper, compound brakes)
Protective functions
• Converter Hardware
• Motor
• Drive/load • Inputs / outputs
• Communication monitoring • Display LEDs
• Fault message storage • Slot for Micro Memory Card
• USB interface
Motivation Targets
• Product for applications placing low to average • Increase the market share and SINAMICS G120
performance requirements quantities sold through new customers or markets
• “Compact” product for convenient sales with • Integration of safety function and fieldbus interface as
optimum price-performance ratio standard
• Convenient handling (e.g. reduced parameter set)
• Strenghen the distributor business
• Migration of MM420/MM440 customers to G120C
G120
G120C G120
CU240E-2
CU240B-2
PM240
PM230 PM250
G120C up to 18,5kW G120 PM230 up to 90kW G120 PM240 up to 250kW
High overload applications + Only for low overload applications - High overload applications +
Dynamic / braking behavior + For non-dynamic applications (PLK) - Dynamic / braking behavior ++
Integrated braking chopper + No braking chopper - Output options for long cable lengths +
Smallest frame size: Compact, small ++
converter, superior output For PM250 up to 90kW:
Side-by-side installation without derating ++ Energy recovery +
Reduced line reactions + Reduced line reactions +
Line reactor no longer necessary + Line reactor no longer necessary +
Modularity +
Lower stock inventory and
simple, fast service
Ruggedness +
Reliable operation and a long
service life
Technology +
Safety technology,
positioning, PFC functions Energy efficiency
and many more
+
PROFIenergy, energy
recovery and many more
Interfaces +
Full TIA integration, building
systems, third-party systems Simple to Use +
When commissioning,
service, maintenance and
diagnostics
Operator panel
Features
Supply voltage / power range
1AC 200 - 240V +/-10% 0.55 - 4kW/0.75 – 5HP1(Low Overload)
0.37 – 3kW/0.5 – 4HP1 (High Overload)
3AC 200 - 240V +/-10% 0.55 – 7.5kW/0.75 – 10HP1 (Low Overload)
0.37 – 5.5kW/0.5 – 4.5HP1 (High Overload)
3AC 380 - 480V +/-10% 0.55 – 250kW/0.75 – 400HP1 (Low Overload)
0.37 – 200kW/0.5 – 300HP1 (High Overload)
Overload capability (load cycle, 300 seconds)
Low Overload: 150% for 3 seconds plus 110% for 57 seconds
High Overload ( 75kW): 200% for 3 seconds plus 150% for 57 seconds
High Overload (>75kW): 160% for 3 seconds plus 136% for 57 seconds
Degree of protection IP20/UL open type for cabinet installation
Ambient temperature 0 ... 40oC, to 60oC with derating
Clock frequency: FSA to FSF (90kW LO) - 4kHz, with derating up to 16kHz
FSF (>90kW LO) - 2kHz, with derating up to 4kHz
Integrated braking chopper to control a braking resistor
Integrated EMC filter up to 90kW LO (Class A filter) to maintain cable-conducted
interference voltages and radiated interference for installations according to EN
61800-3 Category C2
1 Power range from 220 - 240V
Features
• Connecting voltage 3AC 380 - 480V +/-10%
• Rated power 0.37 ... 90kW/0.5 ... 125HP (Low Overload)
• Overload capability
Frame Size A – C: 150% for 3 seconds, 110% for 57 seconds, load cycle 300
seconds
Frame Size D – F: 110% for 60 seconds, load cycle 300 seconds
• Degree of protection IP55/UL Type 12 for decentralized mounting
• Environmental temperature 0 ... 40oC, with derating up to 60oC
• Switching frequency 4kHz, with derating up to 16kHz
• Converter technology with reduced dc link causes reduced line harmonics and
results in reduced cable diameter due to lower line current
• Integrated EMC filter (filter class A) for installations according EN 61800-3
category C2
• Integrated EMC filter (filter class B) for conducted emissions in installations
according EN 61800-3 category C1
• Pluggable motor and power terminals (up to 18,5kW)
• Removable cable connection plate PM can be quickly replaced without
having to disconnect cables
• The fan can be simply replaced at the heat sink
Features
• Connecting voltage 3AC 380 - 480V +/-10%
• Power range 110 ... 400kW / 125 ... 500HP (LO)
based on two frame sizes „GX“ and „HX“
• Overload capability (LO)
135 % for 3 seconds, 100% for 297 seconds, load cycle 300 sec.
110 % for 60 seconds, 100% for 240 seconds, load cycle 300 sec.
• Degree of protection IP20 (standard)
degree of protection IP21, IP23, IP43, IP54 (optional)
• Environmental temperature 0 ... 40oC, with derating up to 50oC
can be enhanced with optional anti condensing heaters to - 10oC
• Two cabinet types available:
Type A: Standard type supporting the complete option spectrum
Type C: Compact version covering a reduced spectrum of options
• IOP provided as default panel solution
• Option variety similar to SINAMICS G150 including Line Harmonic
Filter, without special solutions for marine or chemical industry
• Cabinet delivery includes the complete mounted option package as
a ready for connection and type tested system solution
Operator panel
Advanced I/O
Special I/O For sensorless For standard configuration
configuration for basic applications applications in
Vector control
HVAC, pumps and with variable- general
speed drives machinery Encoder
fans
construction connection
Special functions SLVC control,
high level of user STO as standard EPos
for HVAC, pumps
and fans friendliness. Optional basic Basic and
Basic - I/O extended safety
USS, BACnet safety functions
configuration functions
MS/TP, ModBus, USS, Modbus,
CANopen, USS, Modbus, PROFIBUS, USS, Modbus,
PROFIBUS PROFIBUS PROFINET PROFIBUS,
PROFINET
Intuitive navigation
Key operation with
using a control wheel
menu structure
and menu system
Available as handheld
SINAMICS IOP Available for door SINAMICS BOP-2
device and for door
mounting
mounting
Sine-wave filter
A sine-wave filter limits the voltage gradient and the
capacitive re-charging currents that generally occur at
the motor terminals for inverter operation.
The sine-wave filter at the inverter output supplies almost
sinusoidal voltage at the motor. As a consequence,
standard motors without special cable can be used.
• Operation permissible at pulse frequencies of 4 kHz
up to 8 kHz (sine-wave filter from 160 kW and higher,
only for 4 kHz)
• A power reduction (derating) of 5 % must be taken
into consideration when selecting a suitable inverter
• The output frequency is limited to 150 Hz
• Sine-wave filters can be used with the following Power
Modules
• PM230 FS D-F
• PM240 FS D-GX
• PM250
Basic Functionality
STO, Safe Torque Off
Protection against unintended start of the drive
The drive is safely switched into a non torque condition
A fast continuation of the operation is possible, because the drive has not to be
restarted again.
Extended Functionality
SLS, Safe Limited Speed
Reduction and monitoring of the drive speed for handling at the machine during
operation
No encoder necessary
SIZER
• SIZER is used to engineer the complete drive train
including options, accessories and connection
systems
• SIZER supports the user by providing comprehensive
physical and technical background knowledge.
• It can handle everything from basic single-motor
drives up to complex multi-motor (sectional) drives
• Calculation of low frequent line harmonics and
comparison with the standards
• Calculation of energy consumption and comparison to
alternative configurations
• In order to verify the results, characteristics, data
documentation, mounting/installation drawings etc. are
provided
• The parts list can be exported into the ordering
systems (SAP-VSR)
STARTER
Commissioning
• Wizard-supported first commissioning
Adaption
• Adjustment of the terminals
• Bus configuration
• Setpoint channel
• BiCo connections
• Settings via function-oriented operating masks or
expert list
Optimization
• Automatic identification of the motor data
• Self optimization of the vector mode and the speed
controller
• Trace recording of max. 8 analog and/or digital signals
(from firmware V4.4 on)
Diagnostic
• Monitoring of control and status words and parameter
status, operating and communication conditions
• Comparison of different data sets
SINAMICS G120C
Compact, economic and functionally
optimized for auxiliary drives in machine
building
… The compact drive
The modular drive The compact The specialist for The distributed The distributed
system to address drive distributed or conveyor conveyor
specific central pump, fan technology technology
applications and the specialist specialist
compressor drives integrated in the
motor