0% found this document useful (0 votes)
166 views1 page

4845 PDF

This radiography test report summarizes an inspection of castings for a customer. The inspection found no significant discontinuities in two critical areas labeled A and B, which were inspected using digital radiography on films measuring 4"x6" that met the required density standards. The report provides details of the inspection process and finds the castings to be accepted according to the applicable ASME standards.

Uploaded by

Ravi patel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
166 views1 page

4845 PDF

This radiography test report summarizes an inspection of castings for a customer. The inspection found no significant discontinuities in two critical areas labeled A and B, which were inspected using digital radiography on films measuring 4"x6" that met the required density standards. The report provides details of the inspection process and finds the castings to be accepted according to the applicable ASME standards.

Uploaded by

Ravi patel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

PATELS RADIOGRAPHY SERVICES

C/o. Maa Bhagwati Metal Treatment, Survey No. 256, Plot No. 87/108, Nr. Jaydeep Chemical,
Shapar - Veraval, Ta. Kotada Sangani, Dist. Rajkot (Gujarat)
An ISO certified company Mobile : +91 9506550647,8905444119 Email : [email protected]

RADIOGRAPHY TEST REPORT


Customer Name & Address : Report No. : 8154/19-20
INVENT CAST PVT. LTD. Date : 19/10/2019
G-561,ROAD-1G Job Desc. : 15MM #150 FB 2PC BLV BODY
Kishan Gate Die No. : 4845
GIDC Lodhika Drawing No. : 12-20-03-301CDEV Rev.6
Metoda Heat No. : K254J
RAJKOT 360 003 Sr.No./RT No. : RT 6095
Gujarat, India RSS No. :-

Party : WS No. & Dt.: 0436/18-10-2019


PO No. : Technique : DWSI
Job : Casting Material : ASTM A216 GR.WCB
Test Carried Out at : OUR SITE RT Coverage : ASME B 16.34 (CRITICAL AREA)
Radiation Source : IR-192 Film : CARESTREAM AA400
Exposure Time : VARIOUS MIN Screen : Lead
Processing Time : 4 TO 5 MIN Lead Th. (F) : 0.10MM
Source/Focal Spot Size : 2.7DX1.5H Lead Th. (B) : 0.10MM
Source Strength : 32.59 Viewing : SINGLE

Procedure Ref. : ASME SEC-V, Article 2 & 22


Eveluation as per : ASTM E-446(VOL.II)
Accepatable Std. : ASME B16.34 APPENDIX-1,2017

Sr. Thick. Density Sensi- SFD


Identification / Location Film Size I. Q. I. Observation Remarks
No. (MM) Min Max tivity (inch)

1 A 4"X6" 10+10 2.0 4.0 ASTM 17 S 2-4T 24 NSD Accepted


2 B 4"X6" 10+10 2.0 4.0 ASTM 17 S 2-4T 24 NSD Accepted

DENSITY OF FILMS MEASURED AND CONFORMED TO BE BETWEEN 2.0 TO 4.0 Note :


NSD=No Significant Discontinuity, A=Gas Porosity, B=Inclusion, CA;CB;CC;CD=Shrinkage, (1) Report related only to items tested.
D=Crack, E=Hot Tears, F=Insert, SD=Surface Depression, G=Mottling (2) Test results are in compliance with requirements and / or
specifications of the technique.
Date of Testing : 18/10/2019 (3) Test Report shall not be reproduce except in full without written
Film Size : 4"X6" - 2 approval of the laboratory.
Total No. of Films : 2 Nos.
Total Sq. Inches : 48.000

For, PATELS RADIOGRAPHY SERVICES Customer Client External Inspector


*** END OF REPORT *** Page 1 of 1