Training For ALIA Ultrasonic Flowmeter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

In-depth Look at Ultrasonic Flowmeter

Training for ALIA Ultrasonic Flowmeter

ALIA GROUP INC.


Contents

1 Overview

2 Measuring Principle

3 Products Introduction

4 Function Comparison

5 Installation
1. Overview

Ultrasonic Flowmeter can be directly installed on the pipe without pipe


resection and can sense or eliminate noise with high-performance
microprocessing technology.
Ultrasonic Flowmeter is mainly used in measuring clean fluids and
applied to oil, chemical, metallurgy, electricity, tap water, industrial water,
river water, recycle water. Moreover, Ultrasonic Flowmeter can measure
the uniform fluids with low impurity content(impurity content < 10g/L &
grain size < 1mm), but can not measure the fluids with bubbles & big
solids.

Overview
2. Measuring Principle
While sonic beam is spreading in the liquid, the fluid flow will make the travel time tiny
changed and the change of travel time is proportional to the liquid velocity. Thus, we
will get the liquid velocity :
Shown as the picture 1: on the pipe face, according to a certain position, install one pair
of ultrasonic sensors and the installation ways are Z-way, V-way & W-way. The
ultrasonic pulse of one sensor caused by electric pulse, passing tube wall, fluid, tube
wall again, and then will be received by the other sensor. According to up & down
direction, the travel time of sending ultrasonic pulse to receiving respectively is:

M × D / cos θ
TUP = Sensor Tube Wall Liner Tube
C 0 + V sin θ
M × D / cos θ
TDOWN =
C 0 − V sin θ
ΔT = TDOWN − TUP
According to the above formulas, we will get the mean
velocity of fluid along diameter position:
Picture 1
M ×D ΔT
V = ×
sin 2θ TUP × TDOWN
2. Measuring Principle

M………Spread times of sound beam in liquid


D………Pipe inner diameter
θ………Incidence angle of ultrasonic beam
C0………Sound velocity of fluid when stops
V………Mean velocity of fluid along axial position
TUP………Travel time of sound beam in up position
TDOWN………Travel time of sound beam in down position
△T………Travel time difference in up & dowm pisitions
3. Products Introduction
3.1 Classification
Portable Transit-time Ultrasonic Flowmeter (AUF600 & AUF610)
Wall Mounting Type Ultrasonic Flowmeter (AUF750)
Flange Type Ultrasonic Flowmeter (AUF760)

AUF600 AUF610 AUF750 AUF760


3. Products Introduction
3.1.1 Portable Transit-time Ultrasonic Flowmeter AUF600

Standard Sensor Small Sensor with Middle Sensor with


Support Tool Support Tool

Upstream Cable Downstream Cable Sillicone Grease

Power Supply RS232 Communication Measuring Tape


AUF600 Cable
3. Products Introduction
3.1.2 Portable Transit-time Ultrasonic Flowmeter AUF610

Standard Sensor High-temp. Small Sensor High-temp. Middle


Sensor

Upstream Cable Downstream Cable Sillicone Grease

Power Supply RS232 Communication Cable Measuring Tape

AUF610
Pulse Output Cable Mounting Belt
3. Products Introduction
3.1.3 Wall Mounting Type Ultrasonic Flowmeter AUF750

Standard Sensor High-temp. Small Sensor High-temp. Middle


Sensor

Mounting Belt Signal Cable Sillicone Grease

Fixed Glue

AUF750
3. Products Introduction
3.1.4 Flange Type Ultrasonic Flowmeter AUF760

Flange Type Sensor Signal Cable

AUF760
4. Function Comparison

AUF600 AUF601 AUF750 AUF760


Display 4 line LCD 4 line LCD 4 line LCD 4 line LCD

90~260Vac 90~260Vac
Power Supply Ni-MH Battery Ni-MH Battery
or 8~36Vac or 8~36Vac

Carrying Way Portable Portable Wall Mounted Wall Mounted

Press Keys 18 18 16 16

Accuracy +/-1.0% +/-1.0% +/-1.0% +/-0.5%

Function None None Calorimetry Calorimetry

Applied Size 15~6000mm 15~6000mm 15~6000mm 100~1000mm

Temp. Tolerance -20℃~+110℃ -40℃~+160℃ -40℃~+160℃ -20℃~+110℃

Batch Control None None Yes Yes

Battery Operation No Battery No Battery


10H 12H
Time Need external power Need external power
4. Function Comparison

Outer Box Aluminium Alloy Impact-resist PVC None None

Installation On Pipe On Pipe On Pipe Flange Type


Way
Aluminum mounting, Specially-made PVC, Specially-made PVC,
Appearance
Sensor Protection easily damage the not easily damage the not easily damage the Flange Type
appearance appearance appearance

Stronger, Weaker, easily install Weaker, easily install


Magnetism
easily clip hands on iron & SUS pipe on iron & SUS pipe

Short-time flowrate Short-time flowrate Long-time flowrate Long-time flowrate


Applied Situation
measurement measurement measurement measurement

Dark gray shell Red shell Gray shell Gray shell


Appearance
Blue panel Black panel Blue panel Blue panel
5. Installation
5.1 Sensor Installation
There are 4 kinds of sensor installations: V-way, Z-way, N-way & W-way.
Usually, small pipes (DN100 ~300mm) use V-way and with V-way, if
there is no signal or bad signal, Z-way will be used. Z-way is given
priority to the iron pipe or the pipe more than DN300mm. N-way & W-
way are less used, which are applied for small pipes less than DN50mm.
5. Installation
5.1.1 V-way Sensor Installaion

V-way is the common way, generally, which is installed on DN15-


400mm pipe. Sometimes, this way is called reflection method.

TOP VIEW OF PIPE


sensors spacing
5. Installation
5.1.2 Z-way Sensor Installation

Z-way is for the pipe between DN200mm and DN6000mm.

TOP VIEW OF PIPE


sensors spacing
5. Installation
5.1.2 W-way Sensor Installation

W-way is for the plastic pipe between DN15mm and DN50mm.

TOP VIEW OF PIPE


sensors spacing
5. Installation
5.1.2 N-way Sensor Installation

N-way is for thin pipe less than DN50mm.

TOP VIEW OF PIPE


sensors spacing
5. Installation
5.2 The Do’s and Don’ts
1) The pipe parameters should be correct, otherwise, the flowmeter will not normally
work.
2) During installation, with enough silicone grease, make sensors stick on the pipe.
Check the displayed signal strength & signal quality, meanwhile, slowly move sensor to
get the strongest signal strength & the highest signal quality. The bigger the pipe size is,
the larger the range for sensor movement is. Please confirm:
‹ Whether the installation distance is same as that given by M25.
‹ Whether the sensor is installed on the same line of pipe axis. Pay special attention to
the pipe rolled up by steel plate, because of its irregular. If signal strength is always 0.00,
it means that the flowmeter does not receive ultrasonic signal.
‹ Whether the parameters(including all the parameters related to pipe) you input are
correct.
‹ Whether the way of sensor installation you choosed is correct.
‹ Whether the pipe is too old or the liner is too thick.
‹ Whether the pipe is empty, too close to valve elbow or there are too many bubbles in
the fluid.
If not the above reasons, but still can not receive signal, pls try to another position.
5. Installation
5.2 The Do’s and Don’ts
3) Make sure that whether the flowmeter can normally work: the stronger the signal is, the
longger the flowmeter stably works and the higher the displayed flowrate reliability is. If the
environmental electromagnetic interference is too strong or too weak, the displayed
flowrate reliability will be low and the possibility of long-time stable work is also low.
4) After installation, power on and check the results are right or not.