200 - EE8552, EE6503 Power Electronics - Notes 1 PDF
200 - EE8552, EE6503 Power Electronics - Notes 1 PDF
200 - EE8552, EE6503 Power Electronics - Notes 1 PDF
com
DISADVANTAGES
0 Power electronic converter circuits have a tendency to generate harmonics in the supply system as
well as in load circuit.
1 AC to DC and AC to AC converters operate at a low input powerfactor
1
Www.BrainKart.com
BrainKart.com
0
It is also known as power electronic conversion circuit.
1
It is a group of electrical and electronic components arranged to form an electric power from one form to
another.
2
The feedback component measures a parameter of the load (Ex. speed) and compares it with the
reference signal.
3
The difference between these two signals controls the instant of turn on of the semiconductor device
4
through the digital circuit.
The load circuit can be controlled over a wide range with the adjustment of the reference signal.
5
A filter is necessary to prevent any harmonics
0 CHARACTERISTICS OF A POWER DIODE
0 Amp-volt characteristics (i-v characteristics)
1 Turn-off characteristics (or reverse-recovery characteristics)
1. Amp-Volt Characteristics of Power Diode
23
Under forward-bias condition, signal diode current increases exponentially and then increases linearly.
Www.BrainKart.com
BrainKart.com
23
In the case of the power diode, it almost increases linearly with the applied voltage as all the layers of
P-I-N remain saturated with minority carriers under forward bias.
24
Thus, a high value of current produces results in voltage drop which mask the exponential part of the
curve.
25
In reverse-bias condition, small leakage current flows due to minority carriers until the avalanche
breakdown appears
5555
After the forward diode comes to null, the diode continues to conduct in the opposite direction
5555
The diode current flows for a reverse-recovery time trr.
5555
Time ta: At this time, Charges stored in the depletion layer is removed.
5555
Time tb: At this time, Charges from the semiconductor layer is removed.
5555
Power loss across diode = vf * if
5555
Ratio tb/ta: Softness factor or S-factor.
3
Www.BrainKart.com
BrainKart.com
23 S-factor: measure of the voltage transient that occurs during the time the diode recovers.
24 S-factor = 1 ⇒ low oscillatory reverse-recovery process. (Soft –recovery diode)
25 S-factor <1⇒ large oscillatory over voltage (snappy-recovery diode or fast-recovery diode).
Www.BrainKart.com
BrainKart.com
7. TURN ON METHODS
Different turn ON methods for SCR are:
1. Forward voltage triggering
5
Www.BrainKart.com
BrainKart.com
23 Gate triggering
24 dv/dt triggering
25 Light triggering
26 Temperature triggering
0 Forward voltage triggering
1
A forward voltage is applied between anode and cathode with gate circuit open.
Junction J1 and J 3 is forward biased.
5
Junction J 2 is reverse biased.
5
As the anode to cathode voltage is increased breakdown of the reverse biased junction J2
occurs.
5
This is known as avalanche breakdown and the voltage at which this phenomena occurs
is called forward break over voltage.
0 Gate triggering
5
Then a positive gate voltage is applied between gate and cathode. In practice the transition from OFF
state to ON state by exceeding VBO is never employed as it may destroy the device.
5
When we require the turning ON of a SCR a positive gate voltage between gate and cathode is applied.
5
When gate supply is given between gate and cathode gate p-layer is flooded with electron from cathode
n-layer.
5
Now the thyristor is forward biased, so some of these electron reach junction J 2.
5
As a result width of J 2 breaks down or conduction at J 2 occur at a voltage less than VBO.
3. dv/dt triggering
0 When SCR is forward biased, junction 1 and 3 are forward biased and junction 2 is reversed biased so it
behaves as if an insulator is place between two conducting plate.
1 Here J1and J3 acts as a conducting plate and J2 acts as an insulator.
2 J2 is known as junction capacitor.
3 So if we increase the rate of change of forward voltage instead of increasing the magnitude of voltage.
4 Junction J2 breaks and starts conducting.
4.0 Temperature triggering
5888
If we increase the temperature the leakage current will also increase and heat dissipation of junction J 2
5889
occurs.
When this heat reaches a sufficient value J 2 will break and conduction starts.
Disadvantages
23
It may cause thermal run away of the device.
24
It is very costly as protection is costly.
5. Light triggering
Due to the irradiation, free charge carriers (electron and hole) are generated.
Now if the intensity is increased above a certain value then it leads to turn ON of SCR. Such SCR are
known as Light activated SCR (LASCR).
Www.BrainKart.com
BrainKart.com
0 Delay time
1 Rise time
2 Spread time
23 Delay time
23 Gate current 0.9Ig to 0.1 I.
24 Anode voltage falls from Va to 0.9 Va.
25 Anode current rises from forward leakage current to 0.1I
24 Rise time (t) Time
during which
23 Anode current rises from 0.1Ia to 0.9 Ia
24 Forward blocking voltage falls from 0.9 V to 0.1.
0.0 Spread time (t)
0.0 Time taken by the anode current to rise from 0.9 Ia to I.
2. Time for the forward voltage to fall from 0.1 V to on state voltage drop of 1 to 1.5V.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
The snubber circuit is a series combination of resistor ‘R’ and capacitor ‘C’.
They are connected across the thyristor to be protected.
The capacitor ‘C’ is used to limit the dv/dt across the SCR.
The resistor ‘R’ is used to limit high discharging current through the SCR.
The capacitor charges to full voltage Vs; after which the gate is triggered and SCR is turned ON and high
current flows through SCR.
As di/dt is high, it may damage the SCR. To avoid this, the resistor R in series with ‘C’ will limit the
magnitude of di/dt.
0 OVER VOLTAGE PROTECTION
Internal Overvoltage
During the commutation of SCR, when the anode current decays to zero anode current reverses due to
stored changes.
ii. External over Voltage
0 This is due to external supply and load condition. This is because of
0 The interruption of current flow in an inductive circuit.
1 Lightening strokes on the lines feeding the thyristor systems.
1 The effect of overvoltage is minimized using:
0 RC circuits
1 Nonlinear resistor called voltage clamping device.
Www.BrainKart.com
BrainKart.com
0 OVERCURRENT PROTECTION
1 SCR is protected from overcurrent by using:
Circuit breakers
Fast acting fuses
Circuit Breaker (C.B)
C.B. has long tripping time. So it is used for protecting the device against continuous overload current.
a. Electronic crowbar protection
For overcurrent protection of power converter using SCR, electronic crowbar are used.
23
An additional SCR is connected across the supply which is known as ‘Crowbar SCR’.
24
Current sensing resistor detects the value of converter current.
25
If it exceeds preset value, then gate trigger circuits turn ON the crowbar SCR.
26
So the input terminals are short circuited by SCR and thus it bypass the converter over current.
27
After some time the main fuse interrupts the fault current.
5888 HEAT PROTECTION
To protect the SCR
1. from the local spots
2. Temp rise
SCRs are mounted over heat sinks.
5888 GATE PROTECTION
5
Gate circuit should also be protected from
0.0 Over voltages
0.1 Over currents
5
Protection against over voltage is achieved by connecting a Zener diode ZD across the gate circuit.
5
A resistor R2 connected in series with the gate circuit provides protection against over currents.
10
Www.BrainKart.com
BrainKart.com
Overvoltage across the gate circuit causes the false triggering of SCR
11. TRIAC
This is a three terminal, four layer, bi-directional semiconductor device that controls AC power.
CONSTRUCTION OF TRIAC
0
Two SCRs are connected in inverse parallel with gate terminal as common. Gate terminals is connected to
both the N and P regions.
1
It consists of three terminals namely, main terminal 1(MT1), main terminal 2(MT2), and gate terminal G.
OPERATION OF TRIAC
0
The triac can be turned on by applying the gate voltage higher than break over voltage.
1
When the voltage applied is less than the break over voltage, we use gate triggering method to turn it on.
2
There are four different modes of operations, they are:
11
Www.BrainKart.com
BrainKart.com
0 CHARACTERISTICS OF A TRIAC
First Quadrant Operation of Triac
Voltage at terminal MT2 is positive with respect to terminal MT1 and gate voltage is also positive with
respect to first terminal.
Second Quadrant Operation of Triac
Voltage at terminal 2 is positive with respect to terminal 1 and gate voltage is negative with respect to
terminal 1.
Third Quadrant Operation of Triac
Voltage of terminal 1 is positive with respect to terminal 2 and the gate voltage is negative.
Fourth Quadrant Operation of Triac
Voltage of terminal 2 is negative with respect to terminal 1 and gate voltage is positive.
ADVANTAGES OF TRIAC
0
It can be triggered with positive or negative polarity of gate pulses.
1
It requires only a single heat sink of slightly larger size, whereas for SCR, two heat sinks should be
2
required of smaller size.
It requires single fuse for protection.
3
A safe breakdown in either direction is possible but for SCR protection should be given with parallel
diode.
DISADVANTAGES OF TRIAC
5888
They are not much reliable compared to SCR.
5889
It has (dv/dt) rating lower than SCR.
5890
Lower ratings are available compared to SCR.
12
Www.BrainKart.com
BrainKart.com
0
We need to be careful about the triggering circuit as it can be triggered in either direction.
USES OF TRIAC
1
They are used in control circuits.
2
It is used in High power lamp switching.
3
It is used in AC power control
13. POWER MOSFET
0
A power MOSFET has three terminal device. Arrow indicates the direction of current flow. MOSFET is a
1
voltage controlled device.
The operation of MOSFET depends on flow of majority carriers only.
BASIC CONSTRUCTION
5 + -
The bottom layer is n substrate. On substrate, high resistivity n layer epitaxially grown.
5 -
The n layer is called the drift region. This drift region determines the breakdown voltage of the device.
5 +
On the other side n substrate, a metal layer is deposited to form the drain terminal.
5 - - +
Now p regions are diffused in the epitaxially grown n layer. Further n regions are diffused in p-
regions.
5
SiO2 layer is added which is then etched so as to fit metallic source and gate terminals.
STATIC CHARACTERISTICS
13
Www.BrainKart.com
BrainKart.com
a. Transfer characteristics
5
There is threshold voltage VGST below which the device is off. The magnitude of VGST is of the order of
2 to 3 V.
b. Output characteristics
For low values of VDS, the graph between ID- VDS is almost linear, this indicates a constant value of on-
resistance RDS= VDS/ID.
For given VGS, if VDS is increased, output characteristic is relatively flat indicating that drain current
is nearly constant.
5
The turn off process is initiated by removing the gate to source voltage. Turn off time is composed
of turn off delay time to fall time.
5
Turn off delay time to turn off the MOSFET the input capacitance has to be discharged. During t df
the input capacitance discharge from V1 to VGSP. During fall time, the input
capacitance discharges from VGSP to VGST. During tf drain current falls from ID to zero.
So when VGS ≤ VGST, MOFSET turn off is complete.
Turn on process
The turn on time is defined as the sum of turn- on delay time and rise time of the device.
14
Www.BrainKart.com
BrainKart.com
15
Www.BrainKart.com
BrainKart.com
IGBT CHARACTERISTICS
STATIC CHARACTERISTICS
5893
When the device is off, junction J2 blocks forward voltage and in case of reverse voltage appears across
5894
collector and emitter, junction J1 blocks it.
When VGE is less than the threshold voltage VGET, IGBT is in the off state.
16
Www.BrainKart.com
BrainKart.com
SWITCHING CHARACTERISTICS
Turn on time
Turn on time = Delay time + Rise time
Delay time = Time for collector emitter voltage fall from VCE to 0.9 VCE
tdn=collector current to rise from initial leakage current to 0.1Ic Ic=
Final value of collector current
Rise time
Collector emitter voltage to fall from 0.9VCE to 0.1 VCE. 0.1Ic to Ic
Turn off time
It consists of three intervels
23Delay time tdf
24Initial fall time tf1
25Final fall time tf2
toff= tdf + tf1+ tf2
Delay time tdf
As VGE falls to VGET, Collector current falls from Ic to 0.9Ic.
At the end of the tdf collector emitter voltage begins to rise.
First fall time tf1
the time during which collector emitter voltage rises from VCES to 0.1 VCE
Final fall time tf2
The time during which collector emitter voltage rises from 0.1 V CE to final value VCE.
17
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
5888 By varying the variable resistance, triggering or firing angle is controlled in a full positive half
cycle of the input signal.
5889 During the negative half cycle of the input signal, capacitor charges with lower plate positive
through diode D2 up to the maximum supply voltage Vmax. This voltage remains at -Vmax across
the capacitor till supply voltage attains zero crossing.
5890 During the positive half cycle of the input, the SCR becomes forward biased and the capacitor
starts charging through variable resistance
5891 When the capacitor charging voltage is equal to the gate trigger voltage, SCR is turned ON and
the capacitor holds a small voltage.
5892 Therefore the capacitor voltage is helpful for triggering the SCR even after 90 degrees of the
input waveform.
23 The RC network is connected to the emitter terminal of the UJT which forms the timing circuit.
24 The capacitor is fixed while the resistance is variable.
25 When the voltage is applied, the capacitor starts charging through the variable resistance.
26 By varying the resistance value voltage across the capacitor get varied.
27 Once the capacitor voltage is equal to the peak value of the UJT, it starts conducting and hence
produce a pulse output.
28 This process repeats and produces a train of pulses.
19
Www.BrainKart.com
BrainKart.com
23
In case of DC circuits, there is no natural current zero to turn OFF the SCR. In such circuits,
forward current must be forced to zero with an external circuit to commutate the SCR hence
named as forced commutation.
24
This commutating circuit consist of components like inductors and capacitors called as commutating
25
components.
Forced commutation is classified into different types such as class A, B, C, D, and E.
23 CLASS A COMMUTATION
5888
This is also known as self commutation, or resonant commutation, or load commutation. In this
commutation, the source of commutation voltage is in the load.
5889
This load must be an under damped R-L-C supplied with a DC supply so that natural zero is
obtained.
5890
The commutating components L and C are connected either parallel or series with the load resistance
R.
20
Www.BrainKart.com
BrainKart.com
23
When the thyristor or SCR is triggered, the forward currents starts flowing through it and during this
the capacitor is charged up to the value of E.
24
Once the capacitor is fully charged (more than the supply source voltage) the SCR becomes reverse
biased and hence the commutation of the device.
25
The time for switching OFF the SCR depends on the resonant frequency which further depends on
the L and C components.
5889 CLASS B COMMUTATION
23
This is also a self-commutation circuit in which commutation of SCR is achieved automatically by L
and C components, once the SCR is turned ON.
24
When the DC supply is applied to the circuit, the capacitor charges with an upper plate positive and
25
lower plate negative up to the supply voltage E.
Once the SCR is turned ON, the capacitor starts discharging.
26
When the capacitor is fully discharged, it starts charging with a reverse polarity.
27
Hence a reverse voltage applied across the SCR which causes the commutating current IC to oppose
load current IL.
28
When the commutating current Ic is higher than the load current, the SCR will automatically turn
OFF and the capacitor charges with original polarity.
23 CLASS C COMMUTATION
5888
The main SCR to be commutated is connected in series with the load and an additional or
complementary SCR is connected in parallel with main SCR. This method is also called as
5889
complementary commutation.
In this, SCR turns OFF with a reverse voltage of a charged capacitor.
5890
Initially, both SCRs are in OFF state so the capacitor voltage is also zero.
5891
Therefore, the capacitor starts charging up to the value of E.
5892
When the SCR2 is triggered, SCR is turned ON and simultaneously a negative polarity is applied
across the SCR1.
5893
So this reverse voltage across the SCR1 immediately causes to turn OFF the SCR1. Now the
5894
capacitor starts charging with a reverse polarity.
And again, if the SCR 1 is triggered, discharging current of the capacitor turns OFF the SCR2.
21
Www.BrainKart.com
BrainKart.com
23 CLASS E COMMUTATION
5888
This is also known as external pulse commutation. In this, an external pulse source is used to produce
5889
the reverse voltage across the SCR.
If the SCR need to be commutated, pulse duration equal to the turn OFF time of the SCR is applied.
5890
When the SCR is triggered, load current flows through the pulse transformer.
5891
If the pulse is applied to the primary of the pulse transformer, an emf or voltage is induced in the
22
Www.BrainKart.com
BrainKart.com
23
Www.BrainKart.com
24/10/2017
Page 1 of 34
Page 1 / 34
https://docs.google.com/viewer?url=http://stannescet.ac.in/bala/qbank/EEE/NOTES/1810496999.POWER%20ELECTRONICS%20UNIT%20II%20PROBLEMS%20(1).pdf&embedded=true 1/1
Www.BrainKart.com
BrainKart.com
UNIT II
PHASE-CONTROLLED CONVERTERS
0 APPLICATION OF CONTROLLED RECTIFIER
0 Steel rolling mills, paper mills, printing presses and textile mills employing dc motor drives.
1 Traction systems working on DC
2 Electrochemical and electrometallurgical processes
3 Magnet power supplies
4 Portable hand tool drives
5 HVDC transmission
Www.BrainKart.com
BrainKart.com
T blocks the flow of load current and no voltage is applied across the load R.
By varying the firing angle α, the output voltage can be controlled.
Www.BrainKart.com
BrainKart.com
At wt= π
vo is zero but io is not zero beacause of the load inductance L.
After wt= π
After wt= π, SCR is subjected to reverse anode voltage, but it will not be turned off as the
load
current io is not less than the holding current.
At some angle β>π, io reduces to zero and T is turned off as already it is reverse biased.
After wt=β
After wt=β, vo=0 and io=0.
Angle β is called extinction angle and γ= β-α is called the conduction angle.
Www.BrainKart.com
BrainKart.com
SINGLE PHASE HALF WAVE CONTROLLED RECTIFIER WITH R-L LOAD AND FREE
WHEELING DIODE
At wt=0, source voltage is becoming positive and T is said to be forward biased.
Www.BrainKart.com
BrainKart.com
At wt=α, T is triggered and source voltage Vs appears across the load as Vo.
At wt=π, Vs is zero and just after this instant, as Vs tends to reverse, freewheeling diode FD is forward
biased through the conducting SCR. As a result i o is immediately transferred from T to FD.
At wt=π, T is subjected to reverse voltage and zero current so T is turned off. It is assumed that the
load current does not decay to zero during freewheeling period until SCR is triggered again at
(2π+α).
During the freewheeling period, output voltage Vo is zero.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
-1
Minimum value of firing angle θ1= sin (E/Vm)
Maximum value of firing angle θ2=π-θ1
During positive half cycle
T is fired at an angle α>θ1.
At α= 0 to θ1, as the thyristor is reverse biased, load current io is zero and load voltage Vo=E.
At wt=α, T is triggered and comes to on state. The load voltage follows the source voltage and io
increases.
At wt=π, Vo=0 and io=0.
At wt=β
Due to inductance in the load, the load current io reaches to zero at wt=β.
The load voltage goes to negative and reaches to zero at wt=β.
At wt=β, io=0, then T is turned off automatically.
During negative half cycle
T is reverse biased.
During the period β to 2π+α, io is zero but Vo= E.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
13
Www.BrainKart.com
BrainKart.com
Single phase fully controlled bridge rectifier with RL load-Rectification mode (α< 90º)
14
Www.BrainKart.com
BrainKart.com
Single phase fully controlled bridge rectifier with RL load- Inversion mode (α>90º)
15
Www.BrainKart.com
BrainKart.com
T3, T4 are triggered and with this, the negative line voltage reverse biases T1, T2 and T1, T2
are commutated. The current path is N-T3-RL-T4-P.
16
Www.BrainKart.com
BrainKart.com
Rectification mode
17
Www.BrainKart.com
BrainKart.com
18
Www.BrainKart.com
BrainKart.com
During positive half supply of the AC supply, T1 and D1 are forward biased. When T1 is triggered
at a firing angle wt=α, T1 and D1 come to on state. Now the load current path is P-T1-R-D1-N.
During this period we get positive output voltage and current.
During negative half cycle of the AC supply, T2 and D2 is forward biased. When T2 is triggered at
firing angle wt=π+α, t2 and D2 come to on state. The load current path is N-T2-R-D2-P. During
this period we get positive output voltage and current.
19
Www.BrainKart.com
BrainKart.com
20
Www.BrainKart.com
BrainKart.com
After wt=0, T1 is forward biased, only when source voltage Vm sinwt exceeds E. Thus T1 is
triggered at firing angle wt=α such that Vm sinα>E.
At w=α, T1, D1 comes to the on state.
During that period, we can get positive output voltage and current.
During the period, π to π+α, the input voltage is negative and freewheeling diode FD is
forward biased.
During that period, we can get zero output voltage and positive output current.
21
Www.BrainKart.com
BrainKart.com
22
Www.BrainKart.com
BrainKart.com
THREEPULSE CONVERTERS
THREE PHASE HALF CONTROLLED BRIDGE RECTIFIER
Mode 1: Continuous conduction mode
At instant (π/3+ α), T1 is triggered with a firing angle α<60º. Since R-Y has the highest value
compared to other phases, T1 becomes on. The current path is R-T1-R-L-D3-Y.
Then, phase R-B has the maximum value. Therefore, the current path shifts from Y to B, i.e, T1
continues to conduct but current changes from D3 to D1. Therefore T1 conducts for 120º,
which is the maximum conduction period of the SCRs.
For α<60º, the output voltage will never become negative. The output voltage waveforms
repeat
for every 120º.
Mode 2: Dis Continuous conduction mode
This mode occurs for firing angles α>60º. The output voltage becomes zero because of the
freewheeling action. Freewheeling period is (α-π/3). Therfore input current flows for the period
(π-α) in each half cycle.
When α increases, the duration of input current pulse decreases and the harmonic content in the
source current increases.
23
Www.BrainKart.com
BrainKart.com
24
Www.BrainKart.com
BrainKart.com
25
Www.BrainKart.com
BrainKart.com
26
Www.BrainKart.com
BrainKart.com
27
Www.BrainKart.com
BrainKart.com
Here, T1, T3, T5 forms a positive group, whereas T2, T4, T6 forms a negative group. The positive
group thyristors are turned on when the supply voltage is positive and negative group of thyristors
are turned on when the supply voltage is negative.
The line voltages are
Vry, Vrb, Vyb, Vyr, etc.
The subscripts in sequence appear twice. When first subscript appears twice, the SCR in
the positive group pertaining to that line conducts for 120º.
When second subscript comes twice, the SCR in the negative group pertaining to that line
conducts for 120º.
From this wave form the output voltage is negative. This means DC source is delivering power
to AC source. This operation is called line commutated inverter operation.
For α=0º to 90º, the converter operates in rectification mode and 90º to 180º, the
converter operates in inversion mode.
When terminal 1 of source voltage Vs is positive, current i1 flows through Ls, T1, load and
T2. This is shown in fig.b. i.e., L, T1, T2 and load.
Similarly when terminal 2 of Vs is positive, load current i2 flows through T3, load and T4 and
this is shown as V2, Ls, T3, T4 and load.
Because of the presence of source inductance Ls, the current through outgoing thyristors T3,
T4 decreases gradually to zero from its initial value of Io; whereas in incoming thyristors T1,
T2, the current builds up gradually from zero to full value of load current Io.
28
Www.BrainKart.com
BrainKart.com
29
Www.BrainKart.com
BrainKart.com
At wt=30º, T5 is outgoing SCR and T1 is incoming SCR and both T5, T1 belong to
positive group.
As T1 is triggered, current through T5 starts decaying while through T1 current begins to
build up.
conduct.
After wt=30+µ; T6, T1 conduct.
At wt=90º, as T2 is triggered, I6 begins to decrease and I2 starts building up. Therefore
from wt=90º to 90º+µ, three SCRs T6, T1, T2 conduct.
At wt=90º+µ, I6=0, I2=Io. After wt=90º+µ, only two SCRs T1, T2 conduct. This sequence of
operation repeats with other SCRs of the full converter.
DUAL CONVERTERS
A full converter operates as a rectifier in first quadrant ( Vo,Io positive) from α=0º to 90º and
as an inverter (Vo negative Io positive) from α=90º to 180º in the fourth quadrant.
In the first quadrant, power flows from AC source to the DC load and in the fourth quadrant,
power flows from DC circuit to the AC source.
Four quadrant operation without any mechanical switchover can be achieved by connecting
two full converters. Such an arrangement using two full converters in antiparallel and
connecting to the same DC load is called a dual converter
30
Www.BrainKart.com
BrainKart.com
There are two functional modes of dual converter, one is non circulating current mode and the
other is circulating- current mode. Here, we use non- circulating type of dual converters in
single phase and three phase.
Converter 1 operates in first and fourth quadrant and the second converter operates in second
and third quadrant.
Thus a dual converter using two full converters can give four quadrant operation.
31
Www.BrainKart.com
BrainKart.com
In this converter, only one con converter is in operation and it alone carries the
entire load current.
Only, this converter receives the triggering pulse and the triggering pulse to the other
converter is removed.
If suppose, the converter 1 is in operation and the converter 2 must be turned on,
then first the firing pulse to the converter 1 should be removed so that its load current
will decay to zero and
converter 1 will be made to conduct.
Now the current in converter 2 will build up through the load in the reverse direction.
As firing pulses are withdrawn from converter1, it is idle as long as the converter
2 is in operation.
It should be ensured that during changeover from one converter to another converter,
the load current must decay to zero.
After the outgoing converter stopped working, a delay time of 10 to 20 m sec is
introduced before applying firing pulses to the incoming converter.
This time delay ensures the reliable commutation of SCRs in the outgoing converter. If
the incoming converter is triggered, before completely turning off the outgoing
converter, then the circulating current will flow between the converters.
With non-circulating current mode of dual converter, the load current may be continuous
or discontinuous.
32
Www.BrainKart.com
BrainKart.com
Disadvantages
0 A reactor is required to limit the circulating current. The size and cost of this reactor may be
quite significant at higher power levels.
1 Circulating current causes more losses in the converters, hence the efficiency and
power factor are low. As the converters have to handle load as well as circulating
currents, the thyristors for two converters are rated for higher currents.
33
Www.BrainKart.com
BrainKart.com
34
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
0 INTRODUCTION
0 DC to DC converter is very much needed nowadays as many industrial applications are
dependent upon DC voltage source. The performance of these applications will be improved if
we use a variable DC supply. It will help to improve controllability of the equipment also.
1 Chopper is a basically static power electronics device which converts fixed dc voltage/power to
variable DC voltage or power. It is nothing but a high speed switch which connects and
disconnects the load from source at a high rate to get variable or chopped voltage at the output.
3.1.2 DC CHOPPER
0 A DC chopper is a static device that converts fixed dc input voltage to a variable dc output
voltage directly.
1 Just like a transformer, a chopper can be used to step up or step down the fixed dc output voltage.
Choppers are used in many applications all over the world inside various electronic equipment.
2 A chopper system has a high efficiency, fast response and a smooth control.
Www.BrainKart.com
BrainKart.com
0 During the time period Ton, the chopper is turned on and the load voltage is equal to source
voltage Vs. During the interval Toff, the chopper is off and the load current will be flowing
though the freewheeling diode FD.
1 The load terminals are short circuited by FD and the load voltage is therefore zero during Toff.
2 Thus, a chopped dc voltage is produced at the load terminals. We can see from the graph that the
load current is continuous.
During the time period Ton, load current rises but during Toff load current decays .
Average load Voltage is given by
V0 = Ton/ (Ton +Toff) * Vs = (Ton/T) V = αVs……………… (1.0)
Ton: on -time
Toff: off- time
Equation 1.0 shows that the load voltage is independent of load current it can be also written
as V0 = f. Ton .Vs
f= 1/T = chopping frequency
5 If V0 or the average output voltage is greater than the input voltage Vs, then this type of chopper
is called a step up chopper.
5 For a step-up chopper we can obtain an average output voltage V0 greater than input voltage.
Figure (a) shows the elementary form of a step-up chopper.
0 When the chopper is turned off the current is forced to flow through the diode and load for a time
Toff and as the inductor current cannot die suddenly.
1 When the current decreases the polarity of the emf induced in L is reversed. Fig (c).
As a result the total voltage available across the load is given by the equation V0 = Vs + L (di/dt).
0 The voltage V0 exceeds the source voltage and hence the circuit acts as a step-up chopper and
the energy which is stored in L is released to the load.
3.3.2 VOLTAGE AND CURRENT WAVEFORMS
0 When the chopper is turned ON the current through the inductance L will increase from I1 to I2.
As the chopper is on the source voltage is applied to L that is vL = VS .
1 When the chopper is OFF, the KVL for the figure (c) can be written as
vL – V0+Vs =0 or vL =V0 -Vs where vL is the voltage across L.
0 Variation of source voltage vS , source current IS , load voltage v0 and load current iO is sketched.
Let us assume that the variation of output current is linear, the energy input to inductor from the
source, during the time period Ton, is
Win= Vs (I1+I2/2) Ton
1 During the time Toff, the chopper is off, so the energy released by the inductor to the load is
Woff = (V0-Vs) (I1+I2/2).Toff
2 Let us assume that the system is lossless, then the two energies say Win and Woff are equal.
3 So equating these two we will get
Vs (I1+I2/2) Ton = (V0-Vs) (I1+I2/2).Toff
Vs Ton = (V0-Vs) Toff
V0Toff = Vs (Toff + Ton)
= Vs .T
V0 = VS (T/Toff)
= VS (T/T-Ton)
=VS (1/ (1-α)) ………….(2.0)
0 From the equation 2.0 we can see that the average voltage across the load can be stepped up by
varying the duty cycle.
1 If the chopper in the figure (a) is always off, α=0 and V0= Vs.
2 If the chopper is always on, α=1 and V0 = infinity as we can see from the graph.
3 In practical applications the chopper is turned on and off so that the required step-up average
output voltage, more source voltage is obtained.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
3.3.3 APPLICATION
The principle of step-up chopper can be used for the regenerative braking of DC motors.
Www.BrainKart.com
BrainKart.com
5 So, we can conclude that output voltage is always less than the input voltage and hence the name
step down chopper is justified. The output voltage and current waveform of step down chopper
with resistive load is shown in above figure.
Www.BrainKart.com
BrainKart.com
device used is a thyristor, this circuit is called as a step-down chopper, as the output voltage is
normally lower than the input voltage.
0 When chopper is ON, supply is connected across load. Current flows from supply to load.
1 When chopper is OFF, load current continues to flow in the same direction through FWD due to
energy stored in inductor‘L’.
2 Load current can be continuous or discontinuous depending on the values of ‘L’ and duty cycle
‘d’ For a continuous current operation, load current varies between two limits Imax and Imin
3 When current becomes equal to Imax the chopper is turned-off and it is turned-on when
current reduces to Imin.
Www.BrainKart.com
BrainKart.com
0 In type A chopper the power flow will be always from source to the load as the average voltage
V0 is less than the dc input voltage Vs.
Www.BrainKart.com
BrainKart.com
0 In type B or second quadrant chopper the load must always contain a dc source E.
When the chopper is on, v0is zero but the load voltage E drives the current through the
inductorL and the chopper, L stores the energy during the time Ton of the chopper.
0 When the chopper is off, v0 = (E+ L.di/dt) will be more than the source voltage Vs.
1 Because of this the diode D2 will be forward biased and begins conducting and hence the power
starts flowing to the source.
2 No matter the chopper is on or off the current I0 will be flowing out of the load and is treated
negative. Since VO is positive and the current I0 is negative, the direction of power flow will be
from load to source.
3 The load voltage V0 = (E+L.di/dt ) will be more than the voltage Vs so the type B chopper is
also known as a step up chopper .
Www.BrainKart.com
BrainKart.com
0 The average voltage will be always positive but the average load current might be positive or
negative. The power flow may be life the first quadrant operation ie from source to load or from
load to source like the second quadrant operation.
1 The two choppers should not be turned on simultaneously as the combined action my cause a
short circuit in supply lines.
2 For regenerative braking and motoring these type of chopper configuration is used.
Www.BrainKart.com
BrainKart.com
The power flows from source to load as the average values of both v0 and i0 is positive.
0 From the wave form it is seen that the average value of V0 is positive thus the forth quadrant
operation of type D chopper is obtained.
From the wave forms the Average value of output voltage is given by V0= (Vs Ton-VsToff)/T =
Vs. (Ton-Toff)/T
Www.BrainKart.com
BrainKart.com
First Quadrant
0 During the first quadrant operation the chopper CH4 will be on. Chopper CH3 will be off and
CH1 will be operated.
1 As the CH1 and CH4 is on, the load voltage v0 will be equal to the source voltage Vs and the
load current i0 will begin to flow .
2 v0 and i0 will be positive as the first quadrant operation is taking place.
3 As soon as the chopper CH1 is turned off, the positive current freewheels through CH4 and the
diode D2.
4 The type E chopper acts as a step- down chopper in the first quadrant.
Second Quadrant
0 In this case the chopper CH2 will be operational and the other three are kept off.
1 As CH2 is on negative current will starts flowing through the inductor L.
2 Flows through CH2, E and D4.
Www.BrainKart.com
BrainKart.com
0 Energy is stored in the inductor L as the chopper CH2 is on. When CH2 is off the current will be
fed back to the source through the diodes D1 and D4.
1 Here (E+L.di/dt) will be more than the source voltage Vs .
2 In second quadrant the chopper will act as a step-up chopper as the power is fed back from load
to source
Third Quadrant
0 In third quadrant operation CH1 will be kept off, CH2 will be on and CH3 is operated.
1 For this quadrant, the polarity of the load should be reversed.
2 As the chopper CH3 is on, the load gets connected to the source Vs and v0 and i0 will be negative
and the third quadrant operation will take place. This chopper acts as a step-down chopper
Fourth Quadrant
0 CH4 will be operated and CH1, CH2 and CH3 will be off.
1 When the chopper CH4 is turned on, positive current starts to flow through CH4, D2, E and the
inductor L will store energy.
2 As the CH4 is turned off the current is fedback to the source through the diodes D2 and D3, the
operation will be in fourth quadrant as the load voltage is negative but the load current is positive.
3 The chopper acts as a step up chopper as the power is fed back from load to source.
Effect of Source & Load Inductance
0 The source inductance should be as small as possible to limit the transient voltage.
1 Also source inductance may cause commutation problem for the chopper.
2 Usually an input filter is used to overcome the problem of source inductance.
3 The load ripple current is inversely proportional to load inductance and chopping frequency.
4 Peak load current depends on load inductance.
5 To limit the load ripple current, a smoothing inductor is connected in series with the load.
5 As the name suggest, here the time ratio (i.e. the duty cycle ratio Ton/T) is varied. This kind of
control can be achieved using 2 ways:
0 Pulse Width Modulation (PWM) (Constant frequency system)
1 Frequency Modulation Control (FMC) ( Variable frequency system)
Www.BrainKart.com
BrainKart.com
0 In this technique, the time period is kept constant, but the ‘On Time’ or the ‘OFF Time’ is
varied.
1 Using this, the duty cycle ratio can be varied.
2 Since the ON time or the ‘pulse width’ is getting changed in this method, it is popularly known
as Pulse width modulation.
0 In this control method, the ‘Time Period’ is varied while keeping either of ‘On Time’ or ‘OFF
time’ as constant.
1 In this method, since the time period gets changed, the frequency also changes accordingly, so
this method is known as frequency modulation control.
Www.BrainKart.com
BrainKart.com
0 In this method, current is allowed to fluctuate or change only between two values i.e. maximum
current (I max) and minimum current (I min).
1 When the current is at minimum value, the chopper is switched ON.
2 After this instance, the current starts increasing, and when it reaches up to maximum value, the
chopper is switched off allowing the current to fall back to minimum value.
3 This cycle continues again and again.
Www.BrainKart.com
BrainKart.com
3.7 COMMUTATION
All commutation circuits can be classified into two groups
Forced commutation
Load commutation
Www.BrainKart.com
BrainKart.com
MODE I
0 At t = 0, T1 is on, load RLE is connected across the supply Vo = Vs.
1 There are two current paths. Load current Io, assumed constant, constitute one path and
commutation current ic the other path.
5 Load current Io flows through Vs, T1, load whereas the current ic flows through the oscillatory
circuit formed by C, T1, L and D.
5 The capacitor current first rises from zero to a maximum value when voltage across C is zero
at t= t1/2.
5 As ic decreases to zero, capacitor is charged to voltage (-Vs) at t=t1.
5 The capacitor current changes sinusoidally whereas the capacitor voltage cosinusoidally from t=
0 to t=t1. This voltage is held constant at (-Vs) by diode D.
5 Voltage across TA is (-Vs) at t=0, zero at t1/2 and Vs at t1.
5 At the end of the mode I, at t1, ic=0, it1=Io, vc=-Vs, vTA= Vs, vo= Vs.
MODE II
5 The conditions existing at t1 continue during mode II.
5 For t1≤t≤t2, ic=0,iT1=Io,vc=-Vs, vTA=Vs, vo=Vs, iD=0.
5 During this mode, only T1 is conducting.
MODE III
0 When T1 is to be turned off, TA is triggered at the desired instant t2. Capacitor voltage (-Vs)
appears across T1, it is therefore reverse biased and turned off
1 As the capacitor does the required job of commutating the main thyristor T1, it is called voltage
commutated chopper.
2 Current iT1 becomes zero at t2. After T1 is turned off, capacitor and TA provide the path for load
current Io through Vs, C, TA and the load.
3 The load voltage is the sum of source voltage and voltage across capacitor.
4 Therefore at t2, vo=Vs+Vs= 2Vs and it decreases linearly as the voltage across capacitor decreases.
5 Since capacitor is connected across T1 and TA, vc=vT1.
6 As the capacitor discharges through the load, vc and vT1 change from (-Vs) to zero at (t2+tc)
7 Load voltage vo changes from 2Vs at t2 to Vs at (t2+tc).
8 After (t2+tc), vc and vT1 starts rising from zero towards Vs whereas v o starts falling towards zero.
9 Vc and vT1 change linearly from (-Vs) at t2 to Vs at t3, because load current Io is assumed
constant.
10 Similarly vo changes linearly from 2Vs at t2 to zero at t3.
Www.BrainKart.com
BrainKart.com
5 During mode III, ic= -Io and iTA= Io during mode III.
MODE IV
5 At t3, vc=vT1=Vs and vo=0.
5 At t3, capacitor is slightly overcharged, freewheeling diode FD gets forward biased at t3.
5 In the load circuit formed by FD, TA, C and Vs, vc>vs at t3; therefore current ic tends to go
negative.
5 As ic or iTA, tends to reverse, TA is turned off naturally at t3. Thus at t3, FD gets turned on and
TA is turned off.
5 As a result, load current after t3 free wheels through the load and FD. During freewheeling
period, vTA is slightly negative as C is somewhat overcharged.
5 A reverse voltage is applied across conducting SCR due to which current through SCR becomes
zero and it is getting off. Hence it is called voltage commutation.
5 Other name of this is impulse commutation. It is because a high reverse voltage will turn off the
SCR.
Fig. 3.7.2 Voltage Commutated Chopper- output voltage and current waveform
Www.BrainKart.com
BrainKart.com
MODE I
0 At t = t1, auxiliary thyristor is turned on to commutate main thyristor.
1 With turning on of TA, an oscillatory current ic is set up in the circuit.
2At t2, Vc = - Vs and ic tends to reverse in the auxiliary thyristor TA, it gets naturally commutated.
3 During this mode, T1 remains unaffected, therefore load current and load voltage remain Io and
Vs respectively.
MODE II
5 As TA is reverse biased and turned off at t2, Oscillatory current ic begins to flow through C, L,
D2 and T1.
5 Note that after t2, ic would flow through T1 and not through D1. It is because D1 is reverse
biased by a small voltage drop across conducting thyristor T1.
5 In T1, ic is in opposition to load current io so that iT1= Io-ic.
5 At t3 ic rises to Io so that iT1 = 0. As a result main SCR T1 is turned off at t3. Since oscillating
current through T1 turns it off it is called current commutated chopper.
MODE III
0 After t3 ic supplies load current io and the excess current. iD1 = ic - Io is conducted through diode
D1.
1 The voltage drop in D1 due to (ic-Io) keeps T1 reverse biased for (t4-t3)=tc.
2 At t4, incase vc exceeds Vs, FD comes into conduction, otherwise mode IV follows.
MODE IV
0 At t4, ic reduces to Io, as a result iD1=0 and D1 is turned off.
1 Afetr t4, a constant current equal to Io flows through Vs, C, L, D2 and load.
Www.BrainKart.com
BrainKart.com
0Capacitor c is charged linearly to source voltage Vs at t5, so during time (t5 - t4) ic= Io.
1 As D1 is turned off at t4, vT1=vTa=vc. At t5, vc=Vs, therefore load voltage vo=Vs-Vs=0
MODE V
2 At t5, C is overcharged more than Vs. Therefore, FD gets forward biased and starts to conduct
load current Io at t5.
3 As ic is not zero at t5, C is still connected to load through Vs, C, L and D2.
4 At t6, ic=0 and vc becomes more than Vs. Commutation process ic completed at t6.
5 In this commutation an opposite current pulse will be injected through SCR. As a result currents
decreases and finally comes to zero if both the currents would be equal and opposite.
6 Antiparallel diode is useful to apply the reverse voltage after current through SCR becomes to
zero. The value of reverse voltage is low. So
7 Turn off time increases.
8 Turn off power loss increases.
Www.BrainKart.com
BrainKart.com
0 It has four thyristors T1-T4, one commutating capacitor. T1, T2 act as a pair and T3, T4 act as a
second pair for conducting the load current alternately.
1 When T1, T2 are conducting, they act as the main thyristors and T3, T4, C act as the
commutating components.
2 When T3, T4 are conducting, they act as main thyristors and T1, T2, C act as commutating
components.
3 FD is the freewheeling diode across the load.
Www.BrainKart.com
BrainKart.com
Fig. 3.7.6 Circuit for load commutated chopper b. Current and Voltage waveforms
Www.BrainKart.com
BrainKart.com
DC choppers can also be used as a switched mode regulators. Switched mode regulators convert
unregulated DC input voltage to a regulated DC output voltage.
Www.BrainKart.com
BrainKart.com
The control unit generates the PWM control signal (Vg) for the DC chopper.
Buck converter
Boost converter
Buck boost converter
Cuk converter
We can see about first three types.
BUCK CONVERTER
5
It is also called step down converter, since the average output voltage is less than the input voltage.
Here the power semi conductor device is BJT. It acts as a chopper. The device may be IGBT or
power MOSFET.
The LC filter is used to reduce the ripple content. The operation is divided into two modes.
MODEI OPERATION
The transistor T1 is turned ON by applying base signal from control unit. At t=0, T1 comes to the
ON state.
Now the current flows through T1, L, C and load.
During Ton of the chopper, we can get output voltage and inductor current increases from I1 to I2.
The voltage across the inductor VL= Vs-Vo.
Www.BrainKart.com
BrainKart.com
MODE II OPERATION
At t=t1, the base signal of the transistor is zero, then T1 comes to the OFF state.
During the OFF period Toff, the freewheeling diode comes to conduction state due to stored energy
in the inductor.
Now the inductor current flows through L, C, load and freewheeling diode.
During this period, inductor current decreases from I2 to I1. The voltage across the inductor is – Vo.
The inductor current reaches to I1, again transistor T1 is switched ON. This cycle is repeated.
The inductor current could be continuous or discontinuous depending upon the switching frequency,
filter capacitance and inductance.
Www.BrainKart.com
BrainKart.com
ADVANTAGES
Www.BrainKart.com
BrainKart.com
BOOST CONVERTER
Since the average output voltage is greater than the input voltage it is called boost converter. The
operation can be divided into two modes.
MODE I OPERATION
MODE II OPERATION
At t=t1, the base signal of the transistor is zero, then the transistor T1 comes to the OFF state.
During the off time period Toff, diode D comes to conduction and current flows through inductor,
diode, C and load.
The energy stored in inductor L is transferred to the load. The inductor current decreases from I2 to
I1.
The voltage across the inductor L is (Vs-Vo). Here the output voltage is greater than input voltage.
Www.BrainKart.com
BrainKart.com
ADVANTAGES
This regulator can step up the output voltage
It has high efficiency
Www.BrainKart.com
BrainKart.com
5
Regulated DC power supplies
5
Regenerative braking of DC motors.
The output voltage of the buck boost converter may be either higher or lower than the input voltage.
Here, the output voltage polarity is opposite to that of the supply voltage. It is also called as
inverting regulator.
MODEI OPERATION
Www.BrainKart.com
BrainKart.com
The transistor T1 is turned ON by applying base signal. At t=0, transistor T1 comes to ON state and
diode D is reverse biased.
Now the source current flows through T1 and L. During this TON period, inductor stores energy and
inductor current increases from I1 o I2. Now the voltage across the inductor is Vs.
MODE II OPERATION
At t=t1, T1 is switched off and now the current flows through L, C, D and load.
The inductor current decreases from I2 to I1. Stored energy in inductor L would transferred to the
load.
Now the voltage across the inductor is –Vo. The inductor current reaches I1 and T1 is again switched
ON.
This cycle is repeated.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
ADVANTAGES
It’s output voltage polarity is reversed.
It has high efficiency
The rate fo change of current ( under transistor fault condition) is limited by the inductor L.
The output short circuit protection is also easy to implement in this converter.
DISADVANTAGES
Input current is discontinuous.
In transistor T1, high peak current also flows.
1.12.2FORCED COMMUTATION
In case of DC circuits, there is no natural current zero to turn OFF the SCR. In such circuits, forward
current must be forced to zero with an external circuit to commutate the SCR hence named as
forced commutation.
This commutating circuit consist of components like inductors and capacitors called as commutating
components.
These commutating components cause to apply a reverse voltage across the SCR that immediately
bring the current in the SCR to zero.
Based on the manner in which the zero current achieved and arrangement of the commutating
components, forced commutation is classified into different types such as class A, B, C, D, and E.
This commutation is mainly used in chopper and inverter circuits.
Www.BrainKart.com
BrainKart.com
CLASS A COMMUTATION
5
This is also known as self commutation, or resonant commutation, or load commutation. In this
commutation, the source of commutation voltage is in the load.
5
This load must be an under damped R-L-C supplied with a DC supply so that natural zero is
obtained.
5
The commutating components L and C are connected either parallel or series with the load
resistance R as shown below with waveforms of SCR current, voltage and capacitor voltage.
5
The value of load resistance and commutating components are so selected that they forms a
under damped resonant circuit to produce natural zero.
5
When the thyristor or SCR is triggered, the forward currents starts flowing through it and during
this the capacitor is charged up to the value of E.
5
Once the capacitor is fully charged (more than the supply source voltage) the SCR becomes
reverse biased and hence the commutation of the device.
5
The capacitor discharges through the load resistance to make ready the circuit for the next cycle
of operation.
5
The time for switching OFF the SCR depends on the resonant frequency which further depends
on the L and C components.
5
This method is simple and reliable. For high frequency operation which is in the range above 1000
Hz, this type of commutation circuits is preferred due to the high values of L and C components.
CLASS B COMMUTATION
5
This is also a self commutation circuit in which commutation of SCR is achieved automatically
by L and C components, once the SCR is turned ON. In this, the LC resonant circuit is connected
across the SCR but not in series with load as in case of class A commutation and hence the L and
C components do not carry the load current.
Www.BrainKart.com
BrainKart.com
5
When the DC supply is applied to the circuit, the capacitor charges with an upper plate positive
and lower plate negative up to the supply voltage E.
5
When the SCR is triggered, the current flows in two directions, one is through E+ – SCR – R –
E-and another one is the commutating current through L and C components.
5
Once the SCR is turned ON, the capacitor is starts discharging through C+ – L – T – C-. When
the capacitor is fully discharged, it starts charging with a reverse polarity.
5
Hence a reverse voltage applied across the SCR which causes the commutating current IC to
oppose load current IL.
5
When the commutating current Ic is higher than the load current, the SCR will automatically turn
OFF and the capacitor charges with original polarity.
5
In the above process, the SCR is turned ON for some time and then automatically turned OFF
for some time.
5
This is a continuous process and the desired frequency of ON/OFF depends on the values of L
and C. This type of commutation is mostly used in chopper circuits.
CLASS C COMMUTATION
5
In this commutation method, the main SCR is to be commutated is connected in series with the
load and an additional or complementary SCR is connected in parallel with main SCR. This
method is also called as complementary commutation.
5
In this, SCR turns OFF with a reverse voltage of a charged capacitor. The figure below shows the
complementary commutation with appropriate waveforms.
Www.BrainKart.com
BrainKart.com
5
Initially, both SCRs are in OFF state so the capacitor voltage is also zero. When the SCR1 or
main SCR is triggered, current starts flowing in two directions, one path is E+ – R1 – SCR1 – E-
and another path is the charging current E+ – R2- C+ – C- SCR1 – E- .
5
Therefore, the capacitor starts charging up to the value of E.
5
When the SCR2 is triggered, SCR is turned ON and simultaneously a negative polarity is applied
across the SCR1.
5
So this reverse voltage across the SCR1 immediately causes to turn OFF the SCR1. Now the
capacitor starts charging with a reverse polarity through the path of E+ – R1- C+ – C- SCR2 – E
5
And again, if the SCR 1 is triggered, discharging current of the capacitor turns OFF the SCR2.
5
This commutation is mainly used in single phase inverters with a center tapped transformers. The
Mc Murray Bedford inverter is the best example of this commutation circuit. This is a very
reliable method of commutation and it is also useful even at frequencies below 1000Hz.
CLASS D COMMUTATION
5
This is also called as auxiliary commutation because it uses an auxiliary SCR to switch the
charged capacitor.
5
In this, the main SCR is commutated by the auxiliary SCR. The main SCR with load resistance
forms the power circuit while the diode D, inductor L and SCR2 forms the commutation circuit.
Www.BrainKart.com
BrainKart.com
5
When the supply voltage E is applied, both SCRs are in OFF state and hence the capacitor voltage
is zero. In order to charge the capacitor, SCR2 must be triggered first. So the capacitor charges
through the path E+ – C+ – C- – SCR2- R- E-.
5
When the capacitor is fully charged the SCR2 becomes turned OFF because no current flow
through the SCR2 when capacitor is charged fully.
5
If the SCR1 is triggered, the current flows in two directions; one is the load current path E+ –
SCR1- R- E- and another one is commutation current path C+ – SCR1- L- D- C.
5
As soon as the capacitor completely discharges, its polarities will be reversed but due to the
presence of diode the reverse discharge is not possible.
5
When the SCR2 is triggered capacitor starts discharging through C+ – SCR2- SCR1- C-. When
this discharging current is more than the load current the SCR1 becomes turned OFF.
5
Again, the capacitor starts charging through the SCR2 to a supply voltage E and then the SCR2
is turned OFF. Therefore, both SCRs are turned OFF and the above cyclic process is repeated.
This commutation method is mainly used in inverters and also used in the Jones chopper circuit.
CLASS E COMMUTATION
5
This is also known as external pulse commutation. In this, an external pulse source is used to
produce the reverse voltage across the SCR.
5
The circuit below shows the class E commutation circuit which uses a pulse transformer to
produce the commutating pulse and is designed with tight coupling between the primary and
secondary with a small air gap.
5
If the SCR need to be commutated, pulse duration equal to the turn OFF time of the SCR is
applied. When the SCR is triggered, load current flows through the pulse transformer.
Www.BrainKart.com
BrainKart.com
If the pulse is applied to the primary of the pulse transformer, an emf or voltage is induced in the
secondary of the pulse transformer.
This induced voltage is applied across the SCR as a reverse polarity and hence the SCR is turned
OFF. The capacitor offers a very low or zero impedance to the high frequency pulse.
Www.BrainKart.com
BrainKart.com
PART A
What is meant by dc chopper?
A dc chopper is a high speed static switch used to obtain variable dc voltage from a constant dc
voltage.
5
Smooth acceleration
5
Fast dynamic response
5
Regeneration
Write down the expression for average output voltage for step down chopper.
Average output voltage for step down chopper V0 = αVs, α is the duty cycle
Write down the expression for average output voltage for step up chopper. Average
output voltage for step down chopper V0 = (1/(1-α))Vs, _ is the duty cycle
Www.BrainKart.com
BrainKart.com
What are the different types of chopper with respect to commutation process?
Voltage commutated chopper. b. Current commutated chopper.
c. Load commutated chopper.
Www.BrainKart.com
BrainKart.com
It is the minimum current which must pass through a circuit in order for it to remain in the 'ON'
state. The term can be applied to a single switch or to an entire device.
PART-B
Describe in detail about the types of chopper. Derive an expression for the average output voltage
in terms of input dc voltage & duty cycle (16)
Describe the principle of step-up chopper. Derive an expression for the average output voltage
in terms of input dc voltage & duty cycle. (16)
4. Explain the working of current commutated chopper with aid of circuit diagram
and necessary waveforms. Derive an expression for its output voltage. (16)
5. Explain the working of voltage commutated chopper with aid of circuit diagram
and necessary waveforms. Derive an expression for its output voltage. (16)
Draw the power circuit for step down DC chopper and explain its operation for inductive load.
What is the role of freewheeling diode in such choppers? (16)
Explain the operation of boost and buck boost converter with neat circuit diagrams
and waveforms (16)
Explain the working of voltage commutated chopper with aid of circuit diagram
and necessary waveforms. Derive an expression for its output voltage (16)
Discuss the operation of DC- DC boost converter and prove that its output voltage is always
greater than input voltage (16)
Www.BrainKart.com
BrainKart.com
For 0<t≤T/2, T1 conducts and the load is subjected to a voltage Vs/2 due to the upper voltage source
Vs/2.
At t=T/2, T1 is commutated and T2 is gated ON.
During the period T/2<t≤T, T2 conducts and the load is subjected to a voltage (-Vs/2) due to the lower
voltage source Vs/2.
The load voltage is an alternating voltage waveform of amplitude Vs/2
antiparallel with thyristors will allow the current to flow when the main thyristors are turned off.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
In the three phase inverter, each SCR conducts for 180º of a cycle.
Thyristor pair in each arm, i.e. T1, T4; T3, T6 and T5, T2 are turned on with a time interval of 180º.
It means that T1 conducts for 180º and T4 for the next 180º of a cycle.
Thyristors in the upper group, i.e.T1, T3, T5 conduct at an interval of 120º. It implies that if T1 is
fired at wt=0º, then T3 must be fired at wt=120º and T5 at wt=240º. Same is true for lower group
of SCRs.
In the firing scheme table, first row shows that T1 from upper group conducts for 180º, T4 for the next
180º and then again T1 for 180º and so on.
In the second row, T3 from the upper group is shown to start conducting 120º after T1 starts conducting.
After T3 conduction for 180º, T6 conducts for the next 180º and again T3 for the next 180º and so on.
Www.BrainKart.com
BrainKart.com
5
In the third row, T5 from the upper group starts conducting 120º after T3 or 240º after T1.
5
After T5 conduction for 180º, T2 conducts for next 180º, T5 for the next 180º and so on. In this
manner, the pattern of firing the six SCRs is identified.
5
This table show that T5, T6, T1 should be gated for step I; T6, T1, T2 for step II; T1, T2, T3 for step
III; T2, T3, T4 for step IV and so on.
5
Thus the sequence of firing the thyristors is T1, T2, T3, T4, T5, T6; T1, T2….
5
In every step of 60º duration, only three SCRs are conducting one from upper group and two from
the lower group or two from the upper group and one from the lower group.
5
During step I, thyristors 5, 6, 1 are conducting. The load terminals a and c are connected to the
positive bus of DC source whereas terminal b is connected to the negative bus of DC source.
5
The load voltage is vab=vcb=Vs in magnitude.
For the 120º mode VSI, each thyristor conducts for 120º of a cycle.
Like 180º mode, 120º mode inverter also requires six steps, each of 60º duration, for completing one
cycle of the output AC voltage.
In the table, first row shows that T1 conducts for 120º and for the next 60º, neither T1 nor T4 conducts.
Now T4 is turned on at wt=180º and it further conducts for 120º, i.e. from wt=180º to wt=300º.
This means that for 60º interval from wt=120º to wt=180º, series connected SCRs T1, T4 do not conduct.
At wt=300º, T4 is turned off, then 60º interval elapses.
In the second row, T3 is turned on at wt=120º as in 180º mode inverter.
Now T3 conducts for 120º, then 60º interval elapses during which neither T3 nor T6 conducts.
At wt=300º, T6 is turned on, it conducts for 120º and then 60º interval elapses after which T3 is turned
on again. The third row is completed similarly.
The table shows that T6, T1 should be gated for step I; T1, T2 for step II; T2, T3 for step III and so on.
The sequence of firing is same as for the 180º mode inverter.
During each step, only two thyristors conduct for this inverter, one from upper group and another from
lower group; but in the 180º mode three conductors conduct in each step.
Www.BrainKart.com
BrainKart.com
7. PWM TECHNIQUES
TYPES OF PWM TECHNIQUE
Different types of PWM control technique is given as follows
5
Single pulse width modulation (Single PWM)
5
Multiple pulse width modulation (MPWM)
5
Sinusoidal pulse width modulation (SPWM)
5
Modified Sinusoidal pulse width modulation (MSPWM)
SINGLE PULSE WIDTH MODULATION (SINGLE PWM)
By comparing rectangular reference signal of amplitude (Ar) and a triangular carrier wave (Ac),
the gating signals can be generated as shown in Figure.
This generated gating signal is used to control the output of single phase full bridge inverter. The
fundamental frequency of the output voltage is determined by the
Www.BrainKart.com
BrainKart.com
5
The generation of gating signal is achieved by comparing the reference signal of the amplitude (A r) with
a triangular carrier wave (Ac) as shown Figure.
5
The output frequency (fo) is determined by the frequency of the reference signal. The output
voltage can be controlled by modulation index.
5
The gating signal can be generated by comparing a sinusoidal reference signal with a
triangular carrier wave and the width of each pulse varied proportionally to the amplitude of
a sine wave evaluated at the center of the same pulse.
5
The output frequency (fo) of the inverter can be found by using the frequency of the
reference signal (fr). The rms output voltage (vo) can be controlled by modulation index M
and in turn modulation index is controlled by peak amplitude (Ar).
The fundamental component is increased and its harmonic characteristics are improved. The
main advantages of this technique is increased fundamental component, improved harmonic
characteristics, reduced number of switching power devices and decreased switching losses.
Www.BrainKart.com
BrainKart.com
ADVANTAGES OF PWM
5
The output vo l t a ge co nt r ol w i t h this method c a n be obtained without any
additional components.
5
With this method, lower order harmonic can be eliminated or minimized along with its
output voltage control.
5
It reduces the filtering requirements.
5
The reduction of harmonic contents or the improvement in wave shape can be done by
following methods.
0 Single pulse width modulation
1 Transformer connections
2 Multiple commutation in each half cycle
3 Stepped wave inverters.
5
In the case of single phase pulse width modulation, the width of the pulse is adjusted to reduce
the harmonic.
5
The RMS value of the harmonic voltages of a single pulse width modulated wave is given by
5
Where P is the width of the pulse and Vs is the supply DC voltage.
5
For example, if the third harmonic is to be eliminated, VL3=0,
5
Figure shows a scheme for connecting two inverters and two transformers for harmonic
elimination.
VL=VL1+VL2
0 (√3 [A1 sin (wt-π/6)+A5 sin 5(wt+π/6)+……..]
5
Along with the third harmonics, the multiples of third harmonics, such as 9, 12 are also
eliminated.
HARMONIC REDUCTION BY MULTIPLE COMMUTATION IN EACH HALF CYCLE
5
Instead of having commutation at the end of half cycle, some more commutations can be created
in the half cycle. It is shown in figure.
5
By properly selecting the values of delay angle α1 and α2, any two unwanted lower order
harmonics can be eliminated from the waveform.
Www.BrainKart.com
BrainKart.com
5
Two stepped wave inverters fed from a common DC input voltage is shown in figure.
These inverters are connected to a common load through transformers having turns ratio of
5
1:3 and 1:1 respectively.
The inverter I is so operated that its output voltage is VL1. The output voltage level is either
zero or positive during the first half cycle.
During the second half cycle, the output voltage would be either zero or negative.
Www.BrainKart.com
BrainKart.com
This type of modulation in which the output voltage has only two levels during any half cycle,
is called as two level modulation.
The inverter II is so operated that its output voltage is VL2. It is observed from VL2 waveform
that the level of output voltage is positive, zero and negative during the first half cycle.
Therefore, inverter II is operated with three level modulation.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
4. INTRODUCTION
A circuit that converts DC power into AC power at desired output voltage and frequency is called as an
inverter.
4.1 APPLICATIONS
Adjustable speed AC drives
Induction heating
Standby aircraft power supplies
UPS for computers
HVDC transmission lines, etc..
Inverters can be broadly classified in to two types:
74
Www.BrainKart.com
BrainKart.com
The power circuit diagram of the single phase bridge inverter is shown in figure. The gating signalsfor
the thyristors and the resulting output voltage waveforms are shown in figure.
These voltage waveforms are drawn on the assumption that each thyristor conducts for the duration its
gate pulse is present and is commutated as soon as this pulse is removed.
Ig1- ig4 are gate signals applied respectively to thyristors T1- T4.
75
Www.BrainKart.com
BrainKart.com
It consists of four SCRs and four diodes. In this inverter, number of thyristors and diodes is twice of that
in a half bridge inverter.
The amplitude of output voltage is doubled whereas output power is four times in this inverter as
compared to their corresponding values in the half bridge inverter.
For full bridge inverter, when T1, T2 conduct, load voltage is Vs and when T3, T4 conduct, load voltage
is –Vs.
Frequency of of output voltage can be controlled by varying the periodic time T.
Thyristors T1, T2 are in series across the source. Thyristors T1, T4 or T3, T2 are also in series across the
source.
During inverter operation, it should be ensured that two SCRs in the same branch, such as T1, T2 do not
conduct simultaneously as this would lead to a direct short circuit of the source.
For a resistive load four SCRs would suffice, because load current io and load voltage vo would always
be in phase with each other.
For non-resistive loads, current io will not be in phase with voltage vo and diodes connected in
antiparallel with thyristors will allow the current to flow when the main thyristors are turned off.
As the energy is fed back to the DC source when these diodes conduct, these are called feedback diodes.
D1, D2, D3, D4 are called feedback diodes.
76
Www.BrainKart.com
BrainKart.com
MODES OF OPERATION
The operation of the inverter is divided in to following modes.
MODE I
Thyristor T1 is conducting a constant load current Io, i.e.iT1=Io.
Capacitor is charged to a voltage Vs with right hand plate positive because of the commutation of
previously conducting thyristor T2. In this mode, the equivalent circuit is shown in fig.a.
With T1 conducting, commutation circuit is passive in this mode.
77
Www.BrainKart.com
BrainKart.com
78
Www.BrainKart.com
BrainKart.com
MODE III
After t1, as resonant current ic exceeds Io, the excessive current ic-Io=iD1 circulates through feedback
diode D1. The voltage drop across D1 reverse biases T1 to bring it to forward blocking
capability.
When capacitor voltage vc discharges to zero, resonant current, resonant current ic rises to the peak value
Icp.
After attaining Icp, ic begins to decrease and in so doing, C begins to get charged in the reverse direction.
At t2, ic falls to Io. In case vc is somewhat more than source voltage Vs at t 2, diode D2 gets forward
biased and starts conducting.
MODE IV
After t2, as ic tends to fall below Io, diode current i D1 becomes zero and D1, therefore, stops
conducting.
Constant load current Io continues flowing through Vs/2, TA1, C, L and load. Load current
charges capacitor C linearly with reverse polarity and at t3, v c is somewhat more than Vs.
MODE V
At t3, as vc becomes slightly more than Vs, diode D2 gets forward biased and thus an alternate path for Io
is provided.
Load current Io is now shared by resonant circuit and D2. Current through D2 flows through Vs/2, D2
and load.
After t3, ic begins to decrease whereas iD2 starts building up so that the sum of i c and iD2 is equal to Io.
i.e. ic+iD2=Io.
The supply voltage Vs through D2, is now impressed across the resonant circuit. As current i c is
falling from Io to zero, the energy stored in L is transferred to C and as a consequence, capacitor
is overcharged to a peak voltage Vm at t4.
MODE VI
At t4, iD2 rises to Io and at the same time ic falls to zero. As ic tends to reverse, TA1 is turned off at t4.
Now vc > Vs, capacitor C therefore discharges through Rd, DA1, source voltage Vs, D2, L and C.
Current ic is negative as it flowing opposite to its positive direction. i D2=ic+Io. During this period, iD2 is
more than Io.
At t5, ic becomes zero, vc=-Vs and iD2=Io. Just after t5, as ic tends to reverse, DA1 is turned off.
MODE VII
In this mode, only conducting device is diode D2. A part of the energy stored in the load is delivered to
source.
The decreasing load current io=iD2 becomes zero at t6. Main thyristor T2 is already gated on after TA1 is
fired but it will not get turned on at this moment because of the reverse bias applied to it.
79
Www.BrainKart.com
BrainKart.com
At t6, iD2=0 and T2 is no longer reverse biased. After t6, capacitor charged to voltage –Vs is ready for the
next commutation process.
80
Www.BrainKart.com
BrainKart.com
A basic three phase inverter is a six bridge inverter. In inverter terminology, a step is defined as a change
in the firing from one thyristor to the next thyristor in proper sequence.
For one cycle of 360º, each step would be of 60º interval for a six step inverter.
This means that thyristors would be gated at regular intervals of 60º in proper sequence.
There are two possible patterns of gating the thyristors. In one pattern, each thyristor conducts for 180º
and in the other, each thyristor conducts for 120º.
But in both these patterns, gating signals are applied and removed at 60º intervals of output voltage
waveform.
Therefore both these modes require six six step bridge inverter. These modes of thyristor conduction are
described as follows.
4.4.1 THREE PHASE 180º MODE VSI
81
Www.BrainKart.com
BrainKart.com
82
Www.BrainKart.com
BrainKart.com
In the three phase inverter, each SCR conducts for 180º of a cycle.
Thyristor pair in each arm, i.e. T1, T4; T3, T6 and T5, T2 are turned on with a time interval of 180º.
It means that T1 conducts for 180º and T4 for the next 180º of a cycle.
Thyristors in the upper group, i.e.T1, T3, T5 conduct at an interval of 120º. It implies that if T1 is
fired at wt=0º, then T3 must be fired at wt=120º and T5 at wt=240º. Same is true for lower group
of SCRs.
In the firing scheme table, first row shows that T1 from upper group conducts for 180º, T4 for the next
180º and then again T1 for 180º and so on.
In the second row, T3 from the upper group is shown to start conducting 120º after T1 starts conducting.
After T3 conduction for 180º, T6 conducts for the next 180º and again T3 for the next 180º and so on.
In the third row, T5 from the upper group starts conducting 120º after T3 or 240º after T1.
After T5 conduction for 180º, T2 conducts for next 180º, T5 for the next 180º and so on. In this manner,
the pattern of firing the six SCRs is identified.
This table show that T5, T6, T1 should be gated for step I; T6, T1, T2 for step II; T1, T2, T3 for step III;
T2, T3, T4 for step IV and so on.
Thus the sequence of firing the thyristors is T1, T2, T3, T4, T5, T6; T1, T2….
In every step of 60º duration, only three SCRs are conducting one from upper group and two from the
lower group or two from the upper group and one from the lower group.
During step I, thyristors 5, 6, 1 are conducting. The load terminals a and c are connected to the positive
bus of DC source whereas terminal b is connected to the negative bus of DC source.
The load voltage is vab=vcb=Vs in magnitude.
83
Www.BrainKart.com
BrainKart.com
At wt=300º, T6 is turned on, it conducts for 120º and then 60º interval elapses after which T3 is turned
on again. The third row is completed similarly.
The table shows that T6, T1 should be gated for step I; T1, T2 for step II; T2, T3 for step III and so on.
The sequence of firing is same as for the 180º mode inverter.
During each step, only two thyristors conduct for this inverter, one from upper group and another from
lower group; but in the 180º mode three conductors conduct in each step.
84
Www.BrainKart.com
BrainKart.com
85
Www.BrainKart.com
BrainKart.com
This problem is overcome considerably in 120 mode inverter. In this inverter, there is a 60 interval
between the turning off of SCR T1 and turning on of SCR T4. During this 60 interval, SCR T1
can be commutated safely.
Thus, enough time is made available for the outgoing SCR to commutate before the SCR in series is
turned on. Therefore, commutation is more reliable and possibility of two series SCRs
conducting simultaneously is much less.
4.5 VOLTAGE CONTROL IN SINGLE PHASE INVERTERS
AC loads may require constant or adjustable voltage at their input terminals. When such loads are
fed by inverters, it is essential that output voltage of the inverters is so controlled as to fulfil the
requirement of AC loads.
Examples of such requirements
An AC load may require a constant input voltage though at different levels. For such a load, any
variations in the DC input voltage must be suitably compensated inorder to maintain a constant
voltage at the AC load terminals at a desired level.
In case of inverter supplies power to a magnetic circuit, such as an induction motor, the voltage to
frequency ratio at the inverter output terminals must be kept constatnt. This avoids saturation in
the magnetic circuit of the device fed by the inverter.
The various methods for the control of output voltage of inverters are as under:
External control of AC output voltage
External control of DC input voltage
Internal control of inverter
5
The first two methods require the use of peripheral components whereas the third method
requires no peripheral components.
External control of AC OUTPUT VOLTAGE
There are two possible methods
5
AC voltage control
5
Series inverter control
a. AC voltage control
86
Www.BrainKart.com
BrainKart.com
5
This method gives rise to higher harmonic content in the output voltage; particularly when the output
voltage from the AC voltage controller is at low level.
5
This method is therefore rarely employed except for low power
applications. b. Series inverter control
5
If the available voltage source is AC, then DC voltage input to the inverter is controlled through
a fully controlled rectifier like an uncontrolled rectifier and a chopper or an AC voltage
controller as shown in figure.
5
If available voltage is DC, then DC voltage input to the inverter is controlled by means of a chopper.
5
In the input voltage control techniques, DC voltage input to inverter is controlled by means of
components external to the inverter, has the following main advantages.
87
Www.BrainKart.com
BrainKart.com
Output voltage waveform and its harmonic content are not affected appreciably as the inverter output
voltage is controlled through the adjustment of DC input voltage to the inverter.
This method of voltage control however suffer from the following disadvantages.
Disadvantages
5
The number of power converters used for the control of inverter output voltage varies from two
to three. More power handling stages result in more losses and reduced efficiency of the entire
scheme.
5
For reducing the ripple content of DC voltage input to the inverter, filter circuit is required in all
types of schemes. Filter circuit increases the cost, weight and size and at the same time reduces
efficiency and makes the transient response sluggish.
5
As the DC input is decreased, the commutating capacitor voltage also decreases.
88
Www.BrainKart.com
BrainKart.com
This is the most popular method of controlling the output voltage and this method is termed as pulse
width modulation (PWM) control.
The advantages possessed by PWM technique are as under:
Advantages
The output voltage control with this method can be obtained without any additional components.
With this method, lower order harmonics can be eliminated or minimized along with its output
voltage control. As higher order harmonics can be filtered easily, the filtering requirements are
minimized.
Disadvantage
The SCRs are expensive as they must possess low turn-on and turn-off times.
4.6 PWM TECHNIQUES
Pulse Width Modulation method is a fixed dc input voltage is given to the inverters and a
controlled ac output voltage is obtained by adjusting the on and off periods of the inverter
components.
This is the most popular method of controlling the output voltage and in this method is known as
pulse width modulation (PWM CONTROL).
4.6.1 TYPES OF PWM TECHNIQUE
Different types of PWM control technique is given as follows
0 Single pulse width modulation (Single PWM)
1 Multiple pulse width modulation (MPWM)
2 Sinusoidal pulse width modulation (SPWM)
3 Modified Sinusoidal pulse width modulation (MSPWM)
5
In single pulse width modulation control technique only one pulse will be there for every half
cycle.
5
The width of the single pulse can be adjusted in order to control the output voltage of the inverter.
5
By comparing rectangular reference signal of amplitude (Ar) and a triangular carrier wave (Ac),
the gating signals can be generated as shown in Figure.
5
This generated gating signal is used to control the output of single phase full bridge inverter. The
fundamental frequency of the output voltage is determined by the
89
Www.BrainKart.com
BrainKart.com
frequency of the reference signal. For this technique the amplitude modulation index (M) can
be defined as
90
Www.BrainKart.com
BrainKart.com
91
Www.BrainKart.com
BrainKart.com
The number of pulses (p) per half cycle is calculated by the carrier
frequency (fc). Number of pulses per half cycle is found by
3.
Www.BrainKart.com
BrainKart.com
5
The output frequency (fo) of the inverter can be found by using the frequency of the
reference signal (fr). The rms output voltage (vo) can be controlled by modulation index M
and in turn modulation index is controlled by peak amplitude (Ar).
5
The number of pulses per half cycle depends on the carrier frequency.
5
The gating signal can be produced by using the unidirectional triangular carrier wave.
93
Www.BrainKart.com
BrainKart.com
The reason is due to the characteristics of the sine wave. Hence this sinusoidal PWM technique is
modified so that the carrier signal is applied during the first and last 600 intervals per half cycle
as shown in Figure.
The fundamental component is increased and its harmonic characteristics are improved. The
main advantages of this technique is increased fundamental component, improved harmonic
characteristics, reduced number of switching power devices and decreased switching losses.
94
Www.BrainKart.com
BrainKart.com
5
In the case of single phase pulse width modulation, the width of the pulse is adjusted to reduce
the harmonic.
5
The RMS value of the harmonic voltages of a single pulse width modulated wave is given by
5
Where P is the width of the pulse and Vs is the supply DC voltage.
5
For example, if the third harmonic is to be eliminated, VL3=0,
5
Similarly, to eliminate fourth harmonic, P=72º
5
By this method, only one harmonic can be eliminated at a time.
95
Www.BrainKart.com
BrainKart.com
96
Www.BrainKart.com
BrainKart.com
Along with the third harmonics, the multiples of third harmonics, such as 9, 12 are also eliminated.
It should be noted that the resultant fundamental component is not twice the individual voltage
but Root3/2(=0.866) of that individual output voltage and the effective output has been
reduced by (1-0.866)=13.4%.
The main drawback of this method
5
The need for more number of inverters and transformers of similar ratings.
97
Www.BrainKart.com
BrainKart.com
The above two simultaneous equations can be solved numerically to calculate α1 and α2 under
the condition that
0<α1<90º and α1<α2<90º
which gives α1=23.62º and α2=33.6º
Similarly any two harmonics can be eliminated by calculating the corresponding values of
α1 and α2.
Disadvantages of this method
5
This method produces a fundamental voltage of 83.9% or 0.839 times the amplitude of
fundamental component of unmodulated voltage wave. So inverter is de rated by (100-83.9)
16.1%.
5
There are additional four commutations per cycle and this leads to more switching losses
which decreases the efficiency of operation.
98
Www.BrainKart.com
BrainKart.com
99
Www.BrainKart.com
BrainKart.com
This type of modulation in which the output voltage has only two levels during any half cycle, is
called as two level modulation.
The inverter II is so operated that its output voltage is VL2. It is observed from VL2 waveform that
the level of output voltage is positive, zero and negative during the first half cycle.
Therefore, inverter II is operated with three level modulation.
The resultant output voltage waveform from a series combination of inverter I and II is obtained by
super imposing the waveforms of figure b) and c) as shown in d).
The load waveform shows that the amplitude of output voltage is 4 Vs and waveform has four steps.
Fourier analysis would give harmonics whose amplitudes would depend upon the values of P1, P2,
P3, P4 and amplitude of VL.
By a proper choice of these parameters, third, fifth, seventh harmonics can be decreased
considerably and the fundamental component is optimized.
The three level modulation of inverter II helps achieving the required wave stepping of the resultant
output voltage waveform.
4.8 CURRENT SOURCE INVERTERS
A CSI converts the input DC current to an AC current at its output terminals. The amplitude of AC
output current can be adjusted by controlling the magnitude of DC input current.
The inverters whose output voltage is maintained constant independent of the load is called voltage
source inverters (VSI).
However the load current is forced to fluctuate from positive to negative and vice versa to cope up
with inductive loads, SCRs with freewheeling diodes are required.
Normally, for maintaining inverter output voltage constant, a large capacitor is connected at the DC
input side of the inverter.
In a current source inverter (CSI) the current from the DC source is maintained at an effectively
constant level, irrespective of load or inverter conditions.
This is achieved by inserting a large inductance in series with the DC supply to enable changes of
inverter voltage to be accommodated at low values of di/dt.
The DC input to CSI is obtained from a fixed voltage AC source through a controlled rectifier
bridge, or through a diode bridge and a chopper.
In order for the current input to CSI to be ripple free, L filter is used before CSI.
The CSI find their use in the following applications:
100
Www.BrainKart.com
BrainKart.com
101
Www.BrainKart.com
BrainKart.com
In this type of CSI, capacitor C in parallel with the load is used for storing the charge for force
commutating the SCRs.
SCRs T1, T2, T3 and T4 form power circuit. T1, T2 together are triggered by gate signals Ig1, Ig2
and T3, T4 by Ig3, Ig4.
Before t=0, let the capacitor voltage be Vc=-V1, i.e., capacitor has right plate positive and left plate
negative.
At t=0, SCRs T1 and T2 are triggered and when T1, T2 become turned ON, capacitor applies reverse
voltage across the previously conducting SCRs T3, T4 and hence turn them off.
The source current I now flows through SCR T1, parallel combination of RC and through T2.
From 0 to T/, IT1=IT2=I, output current Iac=I, Vc changes from –V1 to +V1 through the charging of
C by current Ic. Here, the load voltage VL=Vc.
Thus the waveform of IL=VL/R has the same nature as that of Vc as shown in figure.
When T3, T4 are gated at t=T/2, Vc= V1 reverse biases T1, T2 and therefore these are turned off
immediately.
The source current now flows through T3, parallel combination of R,C and T4.
102
Www.BrainKart.com
BrainKart.com
From instant T/2 to T, iT3=iT4=I, but Iac=-I. The current Iac is a square wave of amplitude I.
103
Www.BrainKart.com
BrainKart.com
In the circuit, the forced commutating circuit components are included. The two capacitors store the
energy necessary for commutation.
The four series diodes effectively prevent the capacitors from discharging through the load in the
interval between inverter commutations.
T1, T2 and T3, T4 are alternatively switched to obtain nearly square wave load current. The
triggering frequency of the SCRs determine the output frequency.
104
Www.BrainKart.com
BrainKart.com
If the inverter feeds a RL load, the voltage and current waveforms are shown in figure.
The operation of this inverter can be divided into four modes.
Www.BrainKart.com
BrainKart.com
T1, T2 are conducting and the current I is established in the circuit consisting of T1, D1, the load, D2
and T2.
The capacitors C1, C2 are charged to a voltage Vc= +VL from the previous half cycle. Note that VL
is greater than the load voltage RI.
MODE II
When T3, T4 are gated on, capacitors C1, C2 apply a reverse bias to T1 and T2 respectively, causing
them to turn off.
However, the load current I continues to flow in the same direction as before, through T3, C1, D1,
the load, D2, C2 and T4.
The capacitors are in series with the load and are discharged by the constant current I.
When the capacitor voltages have fallen from VL to R1, diodes D4, D3 conduct and mode 2 is
terminated.
MODE III
SCRs T3, T4 and all four diodes are now conducting so that the load is effectively connected in
parallel with both commutating capacitors.
This RLC circuit undergoes a transient response during which the load current falls to zero and
reverse.
When a load current attains a value –I, diodes D1 and D2 become reverse biased.
This terminates mode 3 and completes the commutation process.
MODE IV
For the next half cycle, the source current I is flowing through T3, D3, the load, D4 and T4.
Note that the capacitor voltage is now –VL and the capacitor hold this voltage until the next
commutation.
The DC current source delivers a unidirectional current I to the inverter and when the inverter
feeds a reactive or regenerative load, the DC supply current cannot reverse as it did in the
case of a voltage source inverter (VSI).
However, the feedback diodes of VSI have been removed, allowing the DC link voltage to
change polarity and permitting a return of energy to the DC link by virtue of a reversal of
DC link voltage rather than a reversal of DC link current.
When SCRs T3, T4 are gated to initiate Mode 2, the inverter input voltage, Vs, goes negative and
remains negative throughout this interval.
Hence, the input power VsI is also negative, indicating that power is being returned to the DC current
source.
106
Www.BrainKart.com
BrainKart.com
PART- A
1. What is meant by inverter?
A device that converts dc power into ac power at desired output voltage and
frequency is called an inverter.
5
Voltage Source Inverter
5
Current Source Inverter
Thyristors require extra commutation circuits for turn off which results in increased complexity of
the circuit. For these reasons thyristors are not preferred for inverters.
5
Current Source Inverter does not require any feedback diodes.
5
Commutation circuit is simple as it involves only thyristors.
An inverter in which the commutating elements are connected in series with the load is called a
series inverter
An inverter in which the commutating elements are connected in parallel with the load is called a
parallel inverter.
107
Www.BrainKart.com
BrainKart.com
Ultrasonic generator.
Induction heating.
Sonar Transmitter
Fluorescent lighting.
5
What is meant by PWM control in inverter?
In this method, a fixed dc input voltage is given to the inverter and a controlled ac output voltage is
obtained by adjusting the on and off periods of the inverter components. This is the most popular
method of controlling the output voltage and this method is termed as PWM control
12. Compare VSI and CSI.
VSI CSI
VSI is fed from a DC voltage source having small CSI is fed with adjustable current from a DC
negligible impedance. voltage source of high impedance.
Input voltage is maintained constant The input current is constant but adjustable.
Output voltage does not dependent on the load the amplitude of output current is independent of
the load
The waveform of the load current as well as its The magnitude of output voltage and its waveform
magnitude depends on the nature of the load depends on the nature of the load impedance
impedance
108
Www.BrainKart.com
BrainKart.com
What are the advantages of 120 degree mode of operation over 180 degree mode of
operation?
We can get continuous conduction in 180 degree mode, whereas discontinuous current flow in
120 degree mode. Hence losses are high in 120 degree mode.
5
Cost of integrated circuit packages for PWM
5
Complexity of circuitry necessary for implementation
5
Radio Frequency Interference/Electromagnetic Interference limits the performance of
the circuitry
5
Voltage spikes in the pulse signal to a rapid succession of switches similar to an impulse
5
Induction heating
5
Lagging VAR compensation
5
Speed control of ac motors
5
Synchronous motor starting.
What is integral cycle control?
Action by a control mechanism that makes changes to the inputs of a manufacturing process based on
the accumulated error over a period of time. Integral action controllers are often used in
conjunction with proportional controllers, which make corrective changes in proportion to the
amount of error in an input, in order make input adjustments faster and more accurate.
5
Average value proportional to duty cycle, this dependence is often observed to follow a linear
trend due to the previous formulaic definition.
5
Low power used in transistors used to switch the signal, and fast switching possible due to
MOSFETS and power transistors at speeds in excess of 100 kHz
5
Alleviates the problem of high heat loses through resistive elements at intermediate voltage
points
What are the applications of ac voltage controllers?
Domestic and industrial heating
Lighting control
Speed control of single phase and three phase ac motors
Transformer tap changing
Mention the difference between Sinusoidal PWM over modified PWM techniques.
74
Www.BrainKart.com
BrainKart.com
In sinusoidal pulse width modulation there are multiple pulses per half-cycle and the width of the
each pulse is varied with respect to the sine wave magnitude. Fig 4(c) shows the gating signals
and output voltage of SPWM with unipolar switching. In this scheme, the switches in the two
legs of the full-bridge inverter are not switched simultaneously, as in the bi-polar scheme.
Space vector modulation (SVM) is an algorithm for the control of pulse width modulation (PWM).
It is used for the creation of alternating (AC) waveforms; most commonly to drive 3 phase AC
powered motors at varying speeds from DC using multiple class-D amplifiers. There are various
variations of SVM that result in different quality and computational requirements.
5
Why diodes should be connected in antiparallel with the thyristors in inverter circuits?
For RL loads, load current will not be in phase with load voltage and the diodes connected in anti-
parallel will allow the current to flow when the main thyristors are turned off. These diodes are
called feedback diodes.
5
Line commutated inverters. b. Load commutated inverters. c. Self-commutated inverters.
5
Forced commutated inverters.
It is device which converts fixed alternating voltage into a variable voltage without change in
frequency.
5
Domestic and industrial heating b. Lighting control
5
High efficiency
5
Flexibility in control c. Less maintenance
75
Www.BrainKart.com
BrainKart.com
The main drawback is the introduction of harmonics in the supply current and the load voltage
waveforms particularly at low output voltages
A CSI converts the input DC current to an AC current at its output terminals. The amplitude of AC
output current can be adjusted by controlling the magnitude of DC input current.
What is the advantage of 120º mode of inverter operation over 180º mode? (Nov/Dec- 2013)
5
In 120º mode of inverter, there is a 60 interval between the turning off of SCR T1 and turning on
of SCR T4. During this 60 interval, SCR T1 can be commutated safely.
5
Thus, enough time is made available for the outgoing SCR to commutate before the SCR in
series is turned on. Therefore, commutation is more reliable and possibility of two series SCRs
conducting simultaneously is much less.
PART-B
State different methods of voltage control inverters. Describe about PWM control in inverter. (16),
Explain different methods of voltage control adopted in inverter with suitable wave forms (16), Explain
different methods of voltage control adopted in inverter with suitable waveforms. (16) (16) (Nov/Dec-
2015) Explain different PWM techniques in detail. (8) (May/ June- 2014)
Explain the operation of 3 phase bridge inverter for 180 degree mode of operation with aid of relevant
phase and line voltage waveforms. (16)
Explain the operation of 3 phase bridge inverter for 120 degree mode of operation with aid of relevant
phase and line voltage waveforms. (16)
Describe the principle of current source inverter. Derive an expression for the average output voltage in
terms of input dc voltage. (16)
Discuss the functioning of three phase VSI with neat circuit diagrams and waveforms. (16)
5
Describe any one PWM technique used in inverter in detail. (8)
5
Explain the working principle of single phase current source inverter. (8)
5
Sinusoidal pulse width modulation as applied to inverter (8)
5
Current source inverter (8)
76
Www.BrainKart.com
BrainKart.com
8. Discuss about the different PWM techniques. (16), What is PWM? List the various PWM techniques and
explain any one of them. (8) (Nov/Dec- 2010), Explain in detail, the various types of PWM methods
employed in an inverter. (Nov/Dec- 2012), Explain different PWM techniques in detail. (8) (May/ June-
2014), Explain the following PWM techniques used in inverter. (May/ June- 2016) Briefly explain the
different types of PWM schemes available for voltage control in an inverter. (16) (Nov/Dec- 2014)
i. Sinusoidal PWM
ii. Multiple PWM
Describe the working of a 1 phase full bridge inverter with relevant circuit and waveforms.
(8) (Nov/Dec- 2010), Describe the working of a single phase full bridge inverter supplying R, RL loads
with relevant circuit diagram and waveforms (May/ June- 2016)
11. Explain the Harmonic reduction by transformer corner lines and stepped wave inverters.
(16) (Nov/Dec- 2010)
Discuss in detail about the functioning of three phase voltage source inverter in 120° operating mode.
(Nov/Dec- 2012), With the neat circuit and output waveforms, explain the operation of three phase
bridge inverter in 120 degree mode of operation. (16) (Nov/Dec- 2015)
Discuss the principle of working of three phase bridge inverter with an appropriate circuit diagram.
Draw the output phase and line voltage waveforms on the assumption that each thyristor conducts for
180º and resistive load is star connected. The sequence of firing of various SCR should also be
indicated. (16) (Nov/Dec- 2013) Explain the operation of 3 phase voltage source inverter in 180º mode
of conduction. (16) (Nov/Dec- 2014) Explain the principle of operation of 3 phase voltage source
inverter with 180º conduction mode with necessary waveforms and circuits. Also obtain the expression
for line to line voltage. (May/ June- 2016)
Draw the circuit diagram of current source inverter and explain its operation with relevant waveforms
(May/ June- 2016)
What is the need for controlling the output of the inverter? Classify the various techniques adopted to
vary the inverter gain and brief on sinusoidal PWM. (May/ June- 2016)
77
Www.BrainKart.com
BrainKart.com
The basic principle of on-off control technique is explained with reference to a single phase full
wave ac voltage controller circuit shown below.
The thyristor switches and are turned on by applying appropriate gate trigger pulses to
connect the input ac supply to the load for ‘n’ number of input cycles during the time
interval
The thyristor switches are turned off by blocking the gate trigger pulses for ‘m’ number of input
cycles during the time interval.
2. PHASE CONTROL
switching device is so operated that load gets connected to AC source for a part of each half cycle of
the input voltage.
The circuit diagram consists of one thyristor in antiparallel with one diode. This configuration is
called single phase half wave voltage controller.
When SCR is forward biased during positive half cycle, it is turned ON at firing angle α.
Load voltage at once jumps to Vm sinα and load current becomes (Vm/R) sinα.
The waveforms of output voltage and current are drawn. Thyristor gets turned off at wt=π for R load.
Www.BrainKart.com
BrainKart.com
5
It consists of two SCRs connected in antiparallel.
5
During positive half cycle, T1 is triggered at firing angle α, it conducts from wt= α to π for
R load.
5
During negative half cycle, T2 is triggered at wt= π+α, it conducts from wt= π+α to 2π.
5
The waveform reveals that positive half cycle is identical with negative half cycle for both
voltage and current waveforms.
SINGLE PHASE VOLTAGE CONTROLLERS WITH R LOAD
5
T1 and T2 are forward biased during positive and negative half cycles respectively.
5
During positive half cycle, T1 is triggered at firing angle α. T1 starts conducting and source
voltage is applied to load from α to π.
5
At π, both vo, io fall to zero. Just after π, T1 is subjected to reverse bias, it is therefore turned off.
5
During negative half cycle, T2 is triggered at (π+α). T2 conducts from π+α to 2π.
5
Soon after 2π, T2 is subjected to a reverse bias, it is therefore commutated. Load and source
current have the same waveform.
Www.BrainKart.com
BrainKart.com
T2 is turned ON at π+α>β. Current io=iT2 starts building up in the reversed direction through the load.
At 2π, vs and vo are zero but iT2=io is not zero.
5
The turns ratio of primary and each secondary is taken as unity for convenience. This
means that for source voltage vs=Vm sinwt, v1=v2=Vm sinwt and sum of two secondary
voltages is 2Vm sinwt.
Www.BrainKart.com
BrainKart.com
For both R and RL type of loads, use only thyristor pair T3, T4 and keep T1, T2 off for
obtaining output voltage control from zero to RMS value V. For obtaining zero output
voltage, α is 180º and for V, α is zero. α is varied from zero to 180º.
a. Resistance load
For resistance load, the load current waveform is identical with output voltage waveform.
When T3, T4 is in operation with T1, T2 off, then the output voltage and current waveforms are
shown in figure.b.
When both pairs T1, T2 and T3, T4 are in operation, then firing angle α for T3, T4 is always
zero and firing angle for T1, T2 pair is varied from 180º to zero for obtaining voltage
from V to 2V.
When T3 is triggered at wt=0, the output voltage follows v2=Vm sinwt curve.
When T1 is triggered at wt= α, voltage v1 reverse biases T3, it is therefore turned off.
Www.BrainKart.com
BrainKart.com
After this, T1 begins conduction and the output voltage jumps from v 2 to v1+v2 and follows 2 Vm
sinwt curve.
At wt= π, output voltage and current are zero.
At this instant T4 is triggered and output voltage follows Vm sinwt curve.
At wt=π+α, when forward biased T2 is triggered, T4 is reverse biased by Vm sinα and it is turned off.
When T2 begins conduction, output voltage follows 2Vm sinwt as shown by negative half
cycle in fig.b. In this figure the output current waveform i o is identical with output
voltage vo waveform.
When both pairs T1, T2 and T3, T4 are in use, the output voltage vo is shown in figure.b.
From 0 to α, vo follows Vm sinwt curve and from α to π, vo adopts to 2Vm sinwt curve.
RL load
During positive half cycle, T3 is conducting and a voltage v2=√2 Vm sinwt is applied to the load.
At wt=α, when T1 is triggered, T3 is turned off by reverse voltage v1 and output voltage
jumps to v1+v2=2Vm sinwt.
At wt=π, v1+v2 reaches zero, but output current io is not zero because of the presence L in
the load.
Thus T1 continues conducting until wt=β, where io decays to zero and T1 which is
already reverse biased by v1+v2, is turned off.
T4 which is already gated at wt=π, starts conducting lowering voltage to v2.
At wt= π+α, T2 is triggered, v1 turns off T4 and output voltage in the negative half cycle
jumps to v1+v2.
At wt= 2π, v1+v2 reaches zero but io is not zero because of L.
At wt= π+β, io reaches zero. T2 which is already reverse biased is turned off and T3 gated at
wt=2π is turned ON lowering the voltage to v2 at wt=π+β.
At wt=2π+α, T1 turns ON and T3 turns off and output voltage jumps from v2 to v1+v2in the
positive half cycle.
5
When it is desired to lower the harmonic content than that in a two stage sequence control, multi
stage sequence control of AC voltage controller is employed.
5
In this, the transformer has n secondary windings. Each secondary is rated for v s/n and vs is the
source voltage.
5
Voltage of terminal a with respect to 0 is vs, voltage of terminal b is (n-1) vs /n and so on.
5
If voltage control from vdo= (n-3)vs/n to vco= (n-2) vs/n is required, then thyristor pair 4
is fired at α=0º and the firing angle thyristor pair 3 is controlled from α=0º to 180º
whereas all other thyristor pairs are kept off.
5
Similarly for controlling voltage from vbo= (n-1) vs/n to vao=vs, thyristor pair 2 is triggered at
α=0º whereas for pair 1, α is varied from 0º to 180º by keeping the remaining
(n-2) SCR pairs off.
Www.BrainKart.com
BrainKart.com
Thus the load voltage can be controlled from vs/n to vs by an appropriate control of triggering the
adjacent thyristor pairs.
The presence of harmnics in the output voltage depends upon the magnitude of voltage variation.
If this voltage variation is small fraction of the total output voltage, the harmonic content in the output
voltage is small.
For example, if voltage variation is vs/n<< (n-1) vs/n for voltage control from (n-2) vs/n to (n-1)vs/n,
then the harmonic content in the output voltage would be small.
Www.BrainKart.com
BrainKart.com
Consider the operation of the cycloconverter to get one-fourth of the input frequency at the
output. For the first two cycles of vs, the positive converter operates supplying current to the
load. It rectifies the input voltage; therefore, the load sees 4 positive half cycles.
In the next two cycles, the negative converter operates supplying current to the load in the reverse
direction.
Note that when one of the converters operates the other one is disabled, so that there is no
current circulating between the two rectifiers.
The frequency of the output voltage, vo in Fig. b is 4 times less than that of vs, the input voltage, i.e.
fo/fi=1/4.
Thus, this is a step-down cycloconverter.
Www.BrainKart.com
BrainKart.com
For converting three phase supply at one frequency to single phase supply at a lower
frequency, the basic principle is to vary progressively the firing angle of the three
thyristors of a three phase half wave circuit.
Firing angle at A is 90º, at B is less than 90º, at C, firing angle is further reduced than it is at B and so
on.
In this manner, a small delay in firing angle is introduced at C, D, E, F and G.
At ‘G’ the firing angle is zero and the mean output voltage given by Vo=V do cosα, is maximum at G.
At A, the mean output voltage is zero as α=90º.
Mean output voltage is obtained by joi8ning points pertaining to average voltage values.
For example, at A, α=90º, Vo=0; at G, α=0º, therefore Vo has the maximum mean output voltage and
so on.
Fabricated output voltage given by thick curve can be resolved into fundamental frequency output
voltage plus several other harmonic components.
The load inductance can filter out the high frequency unwanted harmonics.
Www.BrainKart.com
BrainKart.com
5
The figure shows that for one half cycle of fundamental frequency output voltage, there are eight
half cycles of supply frequency voltage.
5
This shows that output frequency fo=1/8fs where fs is the supply frequency.
5
For obtaining positive half cycle of low frequency output voltage, firing angle is varied from 90º
to zero and then to 90º.
5
For obtaining one cycle of low frequency output voltage, the firing angle should be
varied from 90º to zero degree to 90º for positive half cycle and from 90º to 180º and
back to 90º for negative half cycle.
5
From A to M, there is one half cycle of low frequency output voltage and eight half cycles of
supply frequency, indicating fo= (1/8) fs.
5
Thus a complete cycle of low frequency output voltage can be fabricated from the 3-phase input
voltage waveform by the use of phase controlled converters.
5
The cycloconverter can be made to deliver any pf load.
5
The converter circuit that permits the flow of current during positive half cycle of low frequency
output current is called positive converter group.
5
The other group that permits the flow of current during the negative half cycle of output current is
called negative converter group.
5
The figure uses two three phase half wave converters in antiparallel.
55
The positive group is for the conduction of positive load current and the negative group is for the
flow of negative load current.
55
When output current is positive, positive converter conducts.
55
When output voltage is positive, the positive converter acts as a rectifier.
55
When output voltage is negative, the converter acts as an inverter.
5
When 3-phase low frequency output is required, then three sets of phase controlled 3-phase to 1-
phase circuits are interconnected.(Fig.a)
5
Each phase of the three phase output must have a phase displacement of 120º.
5
The figure shows the circuit arrangement of three phase to three phase cycloconverter using three
sets of three phase half wave circuits employing a total of 18 thyristors.(Fig.b)
5
This device is also called three pulse 3 phase to 3 phase cycloconverter.
Www.BrainKart.com
BrainKart.com
5
Venturini method
5
PWM method
5
Space vector modulation
Www.BrainKart.com
BrainKart.com
Matrix converter
ADVANTAGES
Inherent bidirectional power flow
Sinusoidal input and output waveforms with moderate switching frequency
Possibility of compact design due to absence of DC-link reactive components
Controllable input power factor independent of the output load current
DISADVANTAGES
Non-availability of the bilateral fully controlled monolithic switches capable of high frequency
operation
Control implementation is difficult
An intrinsic limitation of the output-input voltage ratio
Commutation and protection of the power switches
Www.BrainKart.com
BrainKart.com
5. INTRODUCTION
An AC Voltage Controller is a type of thyristor power converter which is used to convert a fixed voltage,
fixed frequency ac input supply to obtain a variable voltage ac output. The RMS value of the ac output
voltage and the ac power flow to the load is controlled by varying (adjusting) the trigger angle ‘α’.
V
0(RMS)
AC V AC Variable AC
Input Voltage
s
RMSO/PVoltage
Voltage f Controller
f s
f
s
S
Www.BrainKart.com
BrainKart.com
The basic principle of on-off control technique is explained with reference to a single phase
full wave ac voltage controller circuit shown below.
The thyristor switches and are turned on by applying appropriate gate trigger pulses to
connect the input ac supply to the load for ‘n’ number of input cycles during the time interval
.
The thyristor switches and are turned off by blocking the gate trigger pulses for ‘m’ number
of input cycles during the time interval .
The ac controller ON time usually consists of an integral number of input cycles.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Fig. 5.5 Single phase full wave voltage controller with resistive load
It consists of two SCRs connected in antiparallel.
During positive half cycle, T1 is triggered at firing angle α, it conducts from wt= α to π for R load.
During negative half cycle, T2 is triggered at wt= π+α, it conducts from wt= π+α to 2π.
Www.BrainKart.com
BrainKart.com
The waveform reveals that positive half cycle is identical with negative half cycle for both voltage and current
waveforms.
The power circuit is therefore introduces no direct component in the supply and load circuit.
This circuit is thus more suited to practical circuits than single phase half wave circuit.
Single phase full wave AC voltage controller is also called single phase bidirectional voltage controller.
For a full wave ac voltage controller, we can see that the two half cycles of output voltage waveforms
are symmetrical and the output pulse time period (or output pulse repetition time) is
radians. Hence we can also calculate the RMS output voltage by using the expression given
below.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Maximum RMS voltage will be applied to the load when α=0, in that case the full sine wave appears
across the load. RMS load voltage will be the same as the RMS supply voltage=
Www.BrainKart.com
BrainKart.com
The figure shows a single phase voltage controller feeding power to a resistive load R. Two thyristors are
connected in anti-parallel.
T1 and T2 are forward biased during positive and negative half cycles respectively.
During positive half cycle, T1 is triggered at firing angle α. T1 starts conducting and source voltage is applied
to load from α to π.
At π, both vo, io fall to zero. Just after π, T1 is subjected to reverse bias, it is therefore turned off.
During negative half cycle, T2 is triggered at (π+α). T2 conducts from π+α to 2π.
Soon after 2π, T2 is subjected to a reverse bias, it is therefore commutated. Load and source current have the
same waveform.
From zero to α, T1 is forward biased, vT1=vs. From α, T1 conducts, vT1 is therefore about 1V.
After π, T1 is reverse biased by source voltage, therefore v T1=vs from π to π+α.
Www.BrainKart.com
BrainKart.com
From π+α to 2π, T2 conducts. T1 is therefore reverse biased by voltage drop across T2 which is about 1 to
1.5V.
The voltage variation vT1 across T1 is shown in figure.
Examination of figure reveals that for any value of α, each thyristor is reverse biased for π/w second.
There is thus no restriction on the value of firing angle α.
Firing angle can therefore be controlled from zero to π and RMS output voltage from Vs to zero.
Here Vs is the RMS value of source voltage.
Circuit turn off time, tc=π/w sec.
Www.BrainKart.com
BrainKart.com
The solution of the above equation gives the output load current which is of the form
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
The term sequence control means that the stages of voltage controllers in parallel are triggered in a
proper sequence one after the other so as to obtain a variable output voltage with low harmonic content.
Www.BrainKart.com
BrainKart.com
Advantages of two stage control of voltage controller over 1- phase full wave AC voltage controller
are
Load current is continuous even for R load as a result the load performance is better.
Wider control of load voltage
Reduction of harmonics in the load and supply current
Disadvantages
5
More complex firing circuitry
5
More expensive voltage controller
a. Resistance load
For resistance load, the load current waveform is identical with output voltage waveform.
When T3, T4 is in operation with T1, T2 off, then the output voltage and current waveforms are shown in
figure.b.
When both pairs T1, T2 and T3, T4 are in operation, then firing angle α for T3, T4 is always zero and firing
angle for T1, T2 pair is varied from 180º to zero for obtaining voltage from V to 2V.
When T3 is triggered at wt=0, the output voltage follows v2=Vm sinwt curve.
When T1 is triggered at wt= α, voltage v1 reverse biases T3, it is therefore turned off.
After this, T1 begins conduction and the output voltage jumps from v 2 to v1+v2 and follows 2 Vm sinwt
curve.
At wt= π, output voltage and current are zero.
At this instant T4 is triggered and output voltage follows Vm sinwt curve.
At wt=π+α, when forward biased T2 is triggered, T4 is reverse biased by Vm sinα and it is turned off.
When T2 begins conduction, output voltage follows 2Vm sinwt as shown by negative half cycle in fig.b.
In this figure the output current waveform i o is identical with output voltage v o waveform.
When both pairs T1, T2 and T3, T4 are in use, the output voltage vo is shown in figure.b.
From 0 to α, vo follows Vm sinwt curve and from α to π, vo adopts to 2Vm sinwt curve.
1/2
2 2
2 2
VRMS= [ /2 ( − )+2 / ( − + )]
2 2
Www.BrainKart.com
BrainKart.com
During positive half cycle, T3 is conducting and a voltage v2=√2 Vm sinwt is applied to the load.
At wt=α, when T1 is triggered, T3 is turned off by reverse voltage v 1 and output voltage jumps to v1+v2=2Vm
sinwt.
At wt=π, v1+v2 reaches zero, but output current i o is not zero because of the presence L in the load.
Thus T1 continues conducting until wt=β, where io decays to zero and T1 which is already reverse
biased by v1+v2, is turned off.
T4 which is already gated at wt=π, starts conducting lowering voltage to v2.
At wt= π+α, T2 is triggered, v1 turns off T4 and output voltage in the negative half cycle jumps to v 1+v2.
At wt= 2π, v1+v2 reaches zero but io is not zero because of L.
At wt= π+β, io reaches zero. T2 which is already reverse biased is turned off and T3 gated at wt=2π is
turned ON lowering the voltage to v2 at wt=π+β.
At wt=2π+α, T1 turns ON and T3 turns off and output voltage jumps from v2 to v1+v2in the positive
half cycle.
When it is desired to lower the harmonic content than that in a two stage sequence control, multi stage
sequence control of AC voltage controller is employed.
In this, the transformer has n secondary windings. Each secondary is rated for v s/n and vs is the source
voltage.
Voltage of terminal a with respect to 0 is vs, voltage of terminal b is (n-1) vs /n and so on.
If voltage control from vdo= (n-3)vs/n to vco= (n-2) vs/n is required, then thyristor pair 4 is fired at
α=0º and the firing angle thyristor pair 3 is controlled from α=0º to 180º whereas all other
thyristor pairs are kept off.
Www.BrainKart.com
BrainKart.com
Similarly for controlling voltage from vbo= (n-1) vs/n to vao=vs, thyristor pair 2 is triggered at
α=0º whereas for pair 1, α is varied from 0º to 180º by keeping the remaining (n-2) SCR pairs off.
Thus the load voltage can be controlled from vs/n to vs by an appropriate control of triggering the adjacent
thyristor pairs.
The presence of harmnics in the output voltage depends upon the magnitude of voltage variation.
If this voltage variation is small fraction of the total output voltage, the harmonic content in the output voltage
is small.
For example, if voltage variation is vs/n<< (n-1) vs/n for voltage control from (n-2) vs/n to (n-1)vs/n, then the
harmonic content in the output voltage would be small.
For obtaining continuous voltage controller over a wide range with low harmonic content and improved
power factor, a multi stage sequence controller must have quite a large number of stages.
Since it is an expensive proposition, an alternative to this, with less number of stages and called single stage
sinusoidal voltage controller is usually employed.
This voltage controller has one primary winding and (n+1) secondary windings. It means that single phase
sinusoidal voltage controller has (n+1) stages.
The top secondary winding numbered A, is called Vernier winding. Its rating is v volts.
The voltage ratings of the remaining n windings are in geometric procession with a ratio of 2.
Thus if v is the voltage rating of the secondary numbered 2 is 2v, that of numbered 3 is 4v, that of numbered 4
is 8v and that of numbered n is 2n-1 .v volts
In the power circuit, TC1, TC2, ….are called control thyristors and TB1, TB2,…are called bypass thyristors.
Vernier winding has two pairs of thyristors marked TCA and TBA.
Thyristors TC1, TC2,…TCn and TB1, TB2, …TBn are either ON or OFF throughout a cycle.
This means that control and bypass thyristors are made to act as switches which remain ON or OFF during a
cycle.
When control thyristor pair for any stage is ON and its bypass thyristor pair is OFF, then voltage of that stage
would appear across the load and a load current would flow accordingly.
On the other hand, if control SCR pair is OFF and bypass pair is ON for any stage, then this particular stage
would be bypassed and will not contribute any voltage across the load.
Thus withn an appropriate series combination of secondaries from 1 to n, the load voltage can be varied from v
to (2 -1)v in discrete steps of v.
As stated above, an additional stage A is employed as a Vernier to permit continuous control of voltage from
zero to v. It is a phase controlled secondary winding.
This winding contributes harmonics to line and load currents.
Since the contribution of voltage by Vernier winding to the load voltage is only a small fraction of the total
load voltage, the harmonic content would be much lower.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
RESISTIVE LOAD
BrainKart.com
VBC=√ ( −)
VCA= √ ( − )
The circuit of a three-phase, delta-connected ac regulator (termed as ac to ac voltage converter) with balanced
resistive load is shown in Fig.
It may be noted that the resistance connected in all three phases are equal. Two thyristors connected back to
back are used per phase, thus needing a total of six thyristors.
Since the phase current in a balanced three-phase system is only (1/√3 ) of the line current, the current rating of the thyristors would be lower than that if the thyristors are placed in the line.
ia=iab-ica
ib=ibc-iab
ic=ica-ibc
Cyclo-converters are constructed using naturally commutated thyristors with inherent capability of
bidirectional power flow.
These can be single phase to single phase, single phase to three- phase and three-phase to three phase
converters.
So the control circuit implementation is not simple because large number of SCRs, typically 4 or 8 SCRs for
single phase and 36 for three- phase supply.
For such controller, a microcontroller or microprocessor or DSP is used to trigger SCRs.
Basically, these are divided into two main types, and are given below.
1. STEP-DOWN CYCLO-CONVERTER
It acts like a step-down transformer that provides the output frequency less than that of input, fo < fi.
Www.BrainKart.com
BrainKart.com
2. STEP-UP CYCLO-CONVERTER
It provides the output frequency more than that of input, fo > fi.
In case of step-down cyclo-converter, the output frequency is limited to a fraction of input frequency,
typically it is below 20Hz in case 50Hz supply frequency. In this case, no separate commutation
circuits are needed as SCRs are line commutated devices.
But in case of step-up cyclo-converter, forced commutation circuits are needed to turn OFF SCRs at
desired frequency. Such circuits are relatively very complex. Therefore, majority of cyclo-
converters are of step-down type that lowers the frequency than input frequency.
Besides the frequency control, cyclo-converter output voltage can be varied by applying phase
control technique. These can be used to provide either fixed frequency output from variable
frequency input value or variable frequency output from fixed frequency input.
These are mainly used in very high power, low speed AC motors and traction systems, especially low
frequency three-phase to single phase systems.
This converter consists of back-to-back connection of two full-wave rectifier circuits. The input voltage, vs
is an AC voltage at a frequency.
For easy understanding assume that all the thyristors are fired firing angle, i.e. thyristors act like
diodes. Note that the firing angles are named as αP for the positive converter and αN for the
negative converter.
Www.BrainKart.com
BrainKart.com
Consider the operation of the cycloconverter to get one-fourth of the input frequency at the output.
For the first two cycles of vs, the positive converter operates supplying current to the load. It
rectifies the input voltage; therefore, the load sees 4 positive half cycles.
In the next two cycles, the negative converter operates supplying current to the load in the reverse direction.
The current waveforms are not shown in the figures because the resistive load current will have the same
waveform as the voltage but only scaled by the resistance.
Note that when one of the converters operates the other one is disabled, so that there is no current
circulating between the two rectifiers.
The frequency of the output voltage, vo in Fig. b is 4 times less than that of vs, the input voltage, i.e.
fo/fi=1/4.
Thus, this is a step-down cycloconverter. On the other hand, cycloconverters that have fo/fi>1 frequency
relation are called step-up cycloconverters.
Note that step-down cycloconverters are more widely used than the step-up ones.
The frequency of vo can be changed by varying the number of cycles the positive and the negative
converters work. It can only change as integer multiples of fi in 1f-1f cycloconverters.
With the above operation, the 1f-1f cycloconverter can only supply a certain voltage at a certain firing angle
a. The dc output of each rectifier is:
Www.BrainKart.com
BrainKart.com
5
A step down cyclo converter does not require forced commutation. It requires phase controlled
converters.
5
These converters need only line, or natural commutation which is provided by AC supply.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Now N2 is commutated and N1 is gated at (5π+α). Load current io becomes more negative than
AB at (6π+α), this is because with N1 on, load voltage is negative.
For four negative half cycles of output voltage, current io is shown in fig.c.
Www.BrainKart.com
BrainKart.com
5
Fig.d is load current waveform inder steady state conditions.
5
The positive group of voltage wave and current wave consists of four pulses and same is true for negative
group of wave.
5
One positive group of pulses along with one negative group of identical pulses constitute one cycle for the
load voltage and load current.
5
The supply voltage has, however gone through four cycles. The output frequency is therefore, fo=1/4fs.
Www.BrainKart.com
BrainKart.com
Load current io becomes zero at wt=β>π but less than (π+α). Thyristor P1 is thus naturally commutated at at
wt=β.
After half a cycle, b is positive with respect to O. Now forward biased SCR P2 is triggered at wt=
π+α. Load current is again positive from A to O and builds up from zero.
At wt=π+β, io decays to zero and P2 is naturally commutated. At 2π+α, P1 is again turned ON.
Load current is seen to be discontinuous.
After four positive half cycles of load voltage and load current, thyristor N2 is gated at (4π+α) when 0 is
positive with respect to b.
As N2 is forward biased it starts conducting but load current direction is reversed i.e from O to A.
After N2 is triggered, load current builds up in the negative direction as shown in fig.c.
In the next half cycle, 0 is positive with respect to ‘a’ but before N1 is fired, io decays to zero and
N2 is naturally commutated.
Now when N1 is gated at (5π+α), io again builds up but it decays to zero before N2 is again gated.
In this manner, four negative half cycles of load voltage and load current, equal to the number of four positive
half cycles, are generated.
Now P1 is again triggered to fabricate further four positive half cycles of load voltage and so on.
For discontinuous load current, natural commutation is achieved, i.e, P1 goes to blocking state before P2 is
gated and so on.
The frequency of output voltage and current is fo=1/4 fs.
Continuous load current
When ‘a’ is positive with respect to 0, P1 is triggered at wt=α, positive output voltage appears across load and
load current starts building up.
At wt=π, supply and load voltages are zero. After wt=π, P1 is reverse biased. As load current is continuous,
P1 is not turned off at wt=π.
When P2 is triggered at π+α, a reverse voltage appears across P1, it is therefore turned off by natural
commutation.
When P1 is commutated, load current has built up to a value equal to RR as shown in fig.c.
With the turning on of P2 at (π+α), output voltage is again positive. As a consequence, load current builds up
further than RR as shown in fig.c.
At (2π+α), when P1 is again turned on, P2 is naturally commutated and load current through P1 builds up
beyond RS.
At the end of four positive half cycles of output voltage, load current is RU.
When N2 is now triggered after P2, load is subjected to a negative voltage cycle and load current io decreases
from positive RU to negative AB as show in fig.c.
Now N2 is commutated and N1 is gated at (5π+α). Load current io becomes more negative than AB at (6π+α),
this is because with N1 on, load voltage is negative.
For four negative half cycles of output voltage, current io is shown in fig.c.
Fig.d is load current waveform inder steady state conditions.
The positive group of voltage wave and current wave consists of four pulses and same is true for negative
group of wave.
One positive group of pulses along with one negative group of identical pulses constitute one cycle for the
load voltage and load current.
Www.BrainKart.com
BrainKart.com
The supply voltage has, however gone through four cycles. The output frequency is therefore, fo=1/4fs.
For converting three phase supply at one frequency to single phase supply at a lower frequency, the
basic principle is to vary progressively the firing angle of the three thyristors of a three phase
half wave circuit.
Firing angle at A is 90º, at B is less than 90º, at C, firing angle is further reduced than it is at B and so on.
In this manner, a small delay in firing angle is introduced at C, D, E, F and G.
At ‘G’ the firing angle is zero and the mean output voltage given by Vo=V do cosα, is maximum at
G.
At A, the mean output voltage is zero as α=90º.
After point G, a small delay in firing angle is further introduced progressively at points H, I, J, K, L and M.
At ‘M’ the firing angle is again 90º and the value of mean output voltage is zero.
The single phase output voltage, fabricated from three phase input voltage is shown by thick curve.
Mean output voltage is obtained by joi8ning points pertaining to average voltage values.
For example, at A, α=90º, Vo=0; at G, α=0º, therefore Vo has the maximum mean output voltage and so on.
Www.BrainKart.com
BrainKart.com
Fabricated output voltage given by thick curve can be resolved into fundamental frequency output voltage
plus several other harmonic components.
The load inductance can filter out the high frequency unwanted harmonics.
The figure shows that for one half cycle of fundamental frequency output voltage, there are eight half cycles
of supply frequency voltage.
This shows that output frequency fo=1/8fs where fs is the supply frequency.
For obtaining positive half cycle of low frequency output voltage, firing angle is varied from 90º to zero and
then to 90º.
For obtaining one cycle of low frequency output voltage, the firing angle should be varied from 90º
to zero degree to 90º for positive half cycle and from 90º to 180º and back to 90º for negative
half cycle.
The magnitude of progressive change in firing angle is given by (reduction factor in frequency) x 120º
If reduction factor (output frequency/ input frequency) is 1/8.
Fig. 5.23 Fabricated and mean output voltage waveforms for a single phase cycloconverter
Therefore, progressive step variation in firing angle =(1/8) x 120º= 15º
In figure, at A, α=90º, at B, α=90-15=75º, at C, α=60º, at D, α=45º….,at G, α=0, at H, α=15º and so on till
α=90º at M.
From A to M, there is one half cycle of low frequency output voltage and eight half cycles of supply
frequency, indicating fo= (1/8) fs.
Thus a complete cycle of low frequency output voltage can be fabricated from the 3-phase input voltage
waveform by the use of phase controlled converters.
The cycloconverter can be made to deliver any pf load.
In a thyristor converter circuit, current can only flow in one direction. For allowing the flow of
current in both the directions during one complete cycle of load current, two three phase half
wave converters must be connected in antiparallel as shown in figure.
The converter circuit that permits the flow of current during positive half cycle of low frequency output
current is called positive converter group.
The other group that permits the flow of current during the negative half cycle of output current is called
negative converter group.
The figure uses two three phase half wave converters in antiparallel.
The positive group is for the conduction of positive load current and the negative group is for the flow of
negative load current.
When output current is positive, positive converter conducts.
When output voltage is positive, the positive converter acts as a rectifier.
Www.BrainKart.com
BrainKart.com
In a dual converter, though the output voltages of the two converters in the same phase have the same average
value, their output voltage waveform as a function of time are different.
Fig. 5.24 circuit of three phase to single phase cycloconverter. A. schematic b. basic circuit configuration
with IG reactor
Fig. 5.25 voltage and current waveforms for a three phase half wave cycloconverter
Www.BrainKart.com
BrainKart.com
As a result, there will be a net potential difference across the two converters. This net
voltage would cause a circulating current in the two converters.
This circulating current can be avoided by removing the gating signals from idle converter or can be
limited to a low value by inserting an intergroup reactor between the positive and negative
converters.
In order that the average value of the output voltage of the two converters are equal in magnitude and
opposite in sign, the sum of their firing angles must be 180º.
In other words αp+αn=180º, where αp=positive group converter, αn=negative group converter
When 3-phase low frequency output is required, then three sets of phase controlled 3-phase to 1-phase circuits
are interconnected.(Fig.a)
Each phase of the three phase output must have a phase displacement of 120º.
The figure shows the circuit arrangement of three phase to three phase cycloconverter using three sets of three
phase half wave circuits employing a total of 18 thyristors.(Fig.b)
This device is also called three pulse 3 phase to 3 phase cycloconverter.
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
Www.BrainKart.com
BrainKart.com
5
Venturini method
5
PWM method
5
Space vector modulation
Www.BrainKart.com
BrainKart.com
ADVANTAGES
Inherent bidirectional power flow
Sinusoidal input and output waveforms with moderate switching frequency
Possibility of compact design due to absence of DC-link reactive components
Controllable input power factor independent of the output load current
DISADVANTAGES
Non-availability of the bilateral fully controlled monolithic switches capable of high frequency
operation
Control implementation is difficult
An intrinsic limitation of the output-input voltage ratio
Commutation and protection of the power switches
APPLICATIONS OF CYCLOCONVERTER
Cement mill drives.
Rolling mills.
Ship propulsion drivers.
Water pumps.
Washing machines
Mine winders.
Industries.
Www.BrainKart.com
BrainKart.com
PART- A
What are the applications of cyclo converter? (Nov/Dec- 2011)
What is Integral cycle control? (Nov/Dec- 2011)
What is meant by cyclo converter? (Nov/Dec- 2010)
Write the output R.M.S. voltage for single phase AC voltage controller with resistance load.
(Nov/Dec- 2010)
Write the principle of operation of cyclo converter. (Nov/Dec- 2012)
Give any two important applications of AC voltage controllers. (Nov/Dec- 2012)
What is a matrix converter? (Nov/Dec- 2013)
Enumerate some of the industrial applications of cyclo-converter. (Nov/Dec- 2013)
What is the control range of firing angle in AC voltage controller with RL load? (May/ June-2014)
What is matrix converter? (May/ June- 2014)
What is cycloconverter?
What is integral cycle control in AC voltage controller?
Write the output RMS voltage for single phase AC voltage controller with resistive load.
PART –B
1. Discuss the working of 2 stage sequence control of AC voltage controller. (16)
(Nov/Dec- 2011)
2. Describe the operation of single phase full wave AC voltage controller with the
help of voltage and current waveform. Also derive the expression for average value of
output voltage. (10) (Nov/Dec- 2010) Explain the operation of single phase full
wave AC voltage regulator with help of voltage and current waveform. (10) (Nov/Dec-
2015)
Describe three-phase to three phase cycloconverter with relevant circuit arrangement using 18
thyristors. (8) (Nov/Dec- 2010)
Discuss the basic principle of 1phase to 1 phase step down cycloconverter for a bridge type
converter. Assume both discontinuous and continuous conduction and draw the load current
Www.BrainKart.com
BrainKart.com
and load voltage waveforms for both the cases. Mark the conduction of various thyristors.
5
(Nov/Dec- 2013)
Write short note on the following: (16) (Nov/Dec- 2013)
0 Integral cycle control
1 Multistage sequence control
2 Step up cyclo converter
3 Matrix converter
With the aid of circuit diagram and waveform explain the operation of i.
power factor control in AC voltage regulation (8)
ii. Single phase full wave AC voltage controller. (8) (May/ June- 2014)
Explain the circuit diagram of three phase to single phase cyclo converter and explain its operation
with necessary waveforms. (16) (May/ June- 2014) Draw the circuit diagram of 3 phase to 1
phase cyclo converter and explain its operation with waveform. (May/ June- 2016) Explain the
working of three phase to single phase cycloconverter with neat circuit
diagram and necessary waveforms. (16) (Nov/Dec- 2015) Discuss the operation of three phase-
single phase cycloconverter with neat circuit diagram and waveforms. (Nov/Dec-2012) Discuss
the working of a 3 phase to single phase cyclo-converter with neat voltage and current
waveforms. (16) (Nov/Dec- 2011) Write short notes on the following: Three phase to single
phase cyclo converter (10) (Nov/Dec- 2014)
5
Write short notes on the following: Matrix converter (Nov/Dec- 2014), Write a short notes on
matrix converter. (6) (Nov/Dec- 2015)
5
Discuss the working of a single phase AC voltage controller with RL loads when its firing angle
is more than the load power factor angle. Illustrate with waveforms. (May/ June- 2016)
With the aid of the circuit diagram, explain the operation of 3phase to 3 phase cyclo converter
employing 3 phase half wave circuit and list few of its applications. (May/ June-2016)
Www.BrainKart.com