Volk Product Catalog
Volk Product Catalog
Volk Product Catalog
catalog
FEB 2019
See the Difference Contact Volk
All lenses are not the same; different lenses will not
deliver the same image quality. Ensure you get the
highest quality lenses to deliver the highest resolution,
online
distortion-free imaging. The image below represents volk.com
an actual side by side comparison of a Volk 20D lens [email protected]
and a non-Volk lens over a 2 mm grid. The photo is
not retouched.
phone
+1 (440) 942-6161
+1 (800) 345-8655
(toll-free in USA)
mail
Volk Non-Volk
Volk Optical Inc.
7893 Enterprise Drive
Mentor, Ohio 44060, USA
volk.com
Our Promise Visit the Volk website to get the information you need to
review, compare, and order your lenses online.
Volk is known worldwide as the premier designer and
manufacturer of the highest quality ophthalmic lenses. An SSL secure certificate guarantees secure transactions
The first aspheric indirect ophthalmoscopy lens was over the internet, protecting your privacy for online
developed by Dr. David Volk 60 years ago. This led purchases. The site’s distributor locator helps you quickly
to the patented double aspheric designs of the 20D, find your closest authorized Volk dealer.
78D, and 90D lenses – the leading standards in the
ophthalmic industry.
Lens Care
For lens care, cleaning, disinfection, and sterilization
instructions refer to https://volk.com/cleaning-and-care
Table of Contents
Classic BIO Lenses 1-3
Pictor Plus 23
Volk iNview® 24
Design Options 42
Warranty Information 43
Ordering Information 44
Classic BIO Lenses
Aspheric ophthalmic lenses were developed by Dr. David Volk in 1956, correcting aberrations induced
by the then-common spherical lenses.
Several developments occurred with the aspheric lens designs through the years, delivering far
superior imaging for BIO examinations. In 1982, all Volk lenses for indirect ophthalmoscopy were
redesigned with both surfaces aspheric, providing a substantial improvement in image quality.
The 20D and other Volk BIO lenses have been known as the industry standard for decades, and are still
widely used in every corner of the world today.
Digital Clear Mag 38° / 49° 3.89x 0.26x 60 mm For detailed optic disc and posterior pole examination
Field of View
36° / 43°
Product code:
VMP5.5 43°
36°
Field of View
36° / 47°
Product code:
V14LC 47°
36°
1
15D
Primary Application – High Magnification Viewing of the Posterior Pole
• High magnification allows thorough examination of the macula and optic disc
• Detailed view of the optic disc facilitates glaucoma screening
Field of View
36° / 47°
Product code:
V15LC
47°
36°
Field of View
Avaliable in 7 different colors 56° / 73°
(shades may vary) Product code:
VPRC 73°
56°
25D
Primary Application – Mid-Peripheral Diagnosis and Treatment
• Field of view extends from the central to the mid-peripheral retina
• Smaller diameter facilitates manipulation within the orbit
Field of View
52° / 68°
Product code:
V25LC
68°
52°
2
28D
Primary Application – Ideal for Fundus Scanning
• Excellent for small pupil diagnosis and treatment
• Available in autoclave sterilizable (ACS®) design (see page 32) or single-use design (see page 36)
Field of View
Avaliable in 7 different colors 53° / 69°
(shades may vary) Product code:
V28LC
69°
53°
30D Small
Primary Application – Small Pupil and Pediatric Examination
• Optical design delivers high resolution views through a small pupil
• Small profile lens for ease of use within the orbit during examination
Field of View
46° / 60°
Product code:
V30SC 60°
46°
Classic BIO Lenses
30D
Primary Application – Small Pupil and Pediatric Examination
• Optical design delivers high resolution views through a small pupil
• Dynamic BIO exam yields a field of view slightly wider than the mid-peripheral retina
Field of View
58° / 75°
Product code:
V30LC 75°
58°
40D
Primary Application – Low Mag Scanning out to the Far-Peripheral Retina
• Widest field of view available in a BIO lens
• Great for small pupil and pediatric exams
Field of View
69° / 90°
Product code:
V40LC
90°
69°
3
Digital Series BIO Lenses
The digital series BIO lenses are a result of Volk’s spirit of innovation and undying commitment to
optical excellence. The double aspheric design was further improved using advanced modeling
techniques coupled with low-dispersion glass thereby reducing chromatic aberrations to provide
superior high definition images. Advanced A/R coating reduces reflections and glare up to 50% more
than traditional A/R coatings.
Product code:
VDGTLCM 72°
55°
4
Classic Series Slit Lamp Lenses
From starting the revolution of slit lamp fundus examination in the 1950s to establishing the standard
of retinal examination, Volk has been committed to providing you with the right tools to diagnose and
treat ocular pathologies.
A series of indirect ophthalmoscopy lenses were developed, resulting in the choice of the 90 Diopter
lens as the most practical for indirect ophthalmoscopy with the slit lamp. The Volk 60D and 90D
lenses were commercialized providing a variety of characteristics: magnification, field of view, and
undilated pupil examination.
5
60D
Primary Application – High Magnification View of the Posterior Pole
• High magnification lens for detailed optic disc and macula imaging
• Ideal diameter for use in the orbital area
Field of View
68° / 81°
Product code:
V60C
81°
68°
6
Super Series Slit Lamp Lenses
Our drive to improve indirect imaging at the slit lamp led us to develop our 2nd Generation slit lamp lenses:
The Super Series. Working with high grade glass types, we reviewed and improved the double aspheric
designs which were so successful in the classic 90D, 78D and 60D lenses, to bring you the Super Series. A
group of four lenses was developed to deliver wide field, high magnification, and specialty features such as
unsurpassed small pupil capabilities – the full diagnostic spectrum!
7
Super 66®
Primary Application – High Magnification Viewing of the Central Retina
• Enables 3D discernment of subtle macular and optic disc details
• 1.0x magnification simplifies optic disc measurement
Field of View
103° / 124°
Product code:
VSVF
124°
103°
Field of View
103° / 124°
Product code:
VSPXL
124°
103°
8
Digital Series Slit Lamp Lenses
Volk has taken double aspheric lenses to the next level with our 3rd Generation slit lamp lenses: The Digital
Series. Similar to the Digital BIO lenses, we combined advanced engineering techniques with higher
grades of glass to produce detailed views of the retina that were previously unattainable at the slit lamp.
Our Digital Series slit lamp lenses are equipped with an advanced A/R coating that reduces reflections and
glare by up to 50%, as compared to a traditional coating.
Whether you’re looking for a wider field of view or higher magnification, Volk’s Digital Series slit lamp
lenses have you covered. The Digital Wide Field®, Digital High Mag®, and Digital 1.0x Imaging Lens offer the
highest image resolution available.
9
Digital Wide Field® | 3rd Generation 90D
Primary Application – High Resolution Pan Retinal Exam
• 40% more field of view than Classic 90D, the widest field of view available in a non-contact lens
• Enhanced double aspheric design paired with high index glass ensures highest resolution stereo image,
even through small pupils
Field of View
103° / 124°
Avaliable in 7 different colors Product code:
(shades may vary) VDGTLWF 103°
124°
Field of View
60° / 72°
Product code:
VDGTL1 124°
103°
10
Indirect Contact Laser Lenses
Volk’s range of indirect contact laser lenses are designed to provide retinal images and are
ergonomically designed keeping both practitioner and patient comfort in mind.
Our exclusive advanced no fluid (ANF+) flange is designed to provide optimal stability during
examination without the need for contact fluid. However, it may be beneficial to utilize a lubricating
fluid for patient comfort. A coupling fluid should be used during laser procedures.
We recommend using flanged versions when using a laser. Flanged versions provide optimal stability
on the cornea. A coupling fluid should be used with our flanged laser lenses.
No flange (NF) versions of our lenses have a smaller corneal contact area than our flanged versions.
A coupling fluid should be used with our no flange (NF) lenses during laser procedures.
Image Laser
Lens Field of View Primary Application
Mag. Spot Mag.
Super Quad® 160 160° / 165° 0.50x 2.0x
Wide field of view for pan retinal examination and
H-R Wide Field 160° / 165° 0.50x 2.0x
laser treatments
®
QuadrAspheric 120° / 144° 0.51x 1.97x
Indirect Contact Laser Lenses
11
Super Quad® 160
Primary Application – Wide Field of View for Pan Retinal Examination and Laser Treatments
• Wide field views for complete retinal imaging out to the ora serrata
• Excellent for PRP and other laser treatments out to the far-peripheral retina
Field of View
160° / 165°
Product code:
With Flange: VSQUAD160NF
No Flange: VSQUAD160
165°
160°
Field of View
160° / 165°
Product code:
With Flange: VHRWF 165°
160°
Field of View
74° / 88°
Product code:
With Flange: VHRC 88°
74°
Field of View
60° / 78°
Product code:
With Flange: VSMAC2.2
78°
60°
No Flange: VTENF
ANF+ Flange: VTEANF+
132°
110°
Field of View
114° / 137°
Product code:
ANF+ Flange: VEPANF+
No Flange: VEPNF
137°
114°
Field of View
100° / 120°
Product code:
With Flange: VQPED 120°
100°
Field of View
115° / 137°
Product code:
With Flange: VPDT 137°
115°
Our exclusive advanced no fluid (ANF+) flange is designed to provide optimal stability during examination
without the need for contact fluid. However, it may be beneficial to utilize a lubricating fluid for patient
comfort. A coupling fluid should be used during laser procedures.
Centralis Direct®
Primary Application – Direct Image Viewing and Treatment of the Posterior Pole
• High profile design eliminates filament reflection
Field of View
26° 22° / 26°
Product code:
22°
VCD
VCDANF+
Field of View
40° 35° / 40°
35°
Product code:
VFUNDUS
Field of View
30° 25° / 30°
25°
Product code:
VFUNDUS20
Note :
Capsulotomy, Iridectomy and Iridotomy lenses are suitable for argon, diode and YAG laser treatments.
Singh Mid-Vitreous
Primary Application – Laser Treatment of Vitreous Floaters
• Enables clear visualization of vitreous floaters from the posterior capsule to the retina
• Unique flanged contact element provides stability during laser procedures and is
Specialty Treatment Lenses
Product code:
VSMV
2D View
Idrees Mid-Vitreous
Primary Application – Laser Treatment of Vitreous Floaters
• Tall lens body makes this the preferred lens for treating patients with deep set eyes
• Flanged contact element provides stability during laser procedures
Product code:
VIMV
2D View
Rapid SLT
Primary Application – SLT Procedures
• Four-mirror design reduces the time taken for the SLT procedure by half
• Simultaneously visualize of all quadrants of the trabecular meshwork
Product code:
VMSLT 1 x 63°
2D View
Selective Laser Trabeculoplasty (SLT)
Primary Application – SLT Procedures
• 1.0x magnification maintains laser spot size and power density at the treatment site
• Large internally reflective facet provides excellent view of the angle
Product code:
VSLT 1 x 63°
15 2D View
Capsulotomy
Primary Application – Laser Capsulotomy Procedures
• Enables precise focusing of the laser beam at the posterior lens capsule
• Laser Window provides a protective barrier for internal imaging components
Product code:
VCAPS
2D View
Blumenthal Iridotomy
Primary Application – Far Periperal Laser Iridotomy Procedures
• Unique contact design allows indentation to open the angle and flatten the
peripheral iris
• Improved lens peformance uses lower energy for less iris tissue damage and post
laser inflammation
• Larger lens housing aids manipulation and allows more oblique viewing
• Aspheric lens element provides superior optical quality for sharply focused laser spots
Product code:
VBIRID
2D View
Product code:
VMPIRID
2D View
Iridectomy
Primary Application – Laser Iridotomy Procedures
• High magnification of the iris ensures precise placement of the laser beam
• Laser Window provides a protective barrier for internal imaging components
Product code:
VIRID
2D View
Blumenthal Suturelysis
Primary Application – Suturelysis Procedures
• Unique pointed tip reduces compressive force needed to visualize sutures,
reducing patient discomfort
• High magnification enables treatment of deep seated sutures
• Unique design facilitates visualization through thick Tenon’s layer or a
subconjunctival hemorrhage
Product code:
VBSL
2D View
16
Gonio Lenses
Volk’s Gonio Lenses are the industry standard for performing static, dynamic, and indentation
gonioscopy. Our no flange G-Series lenses (G-1, G-2, G-3, G-4, and G-6) have a small contact
area which maximizes patient comfort and minimizes corneal wrinkling during dynamic exams.
Volk’s flanged G-Series and coated 3-Mirror gonio lenses can be used to perform laser
trabeculoplasty for patients with primary open angle glaucoma. The standard flange on our
G-Series gonio lenses and the advanced no fluid (ANF+) flange of our coated 3-Mirror lens provide
optimal stability on the cornea during laser procedures. It is important to note that
while the ANF+ flange does not require coupling fluid for routine examination, Volk does
recommend using a coupling fluid for laser procedures.
Every glaucoma specialist should have at least one of Volk’s gonio lenses in their portfolio.
Note :
A coupling fluid should always be used with the flanged version of our G-Series gonio lenses.
No flange (NF) versions have a small corneal contact area and are excellent for diagnostic work. It
may not be necessary to use a contact fluid with these versions (G-Series gonio lenses only).
A coupling fluid should be used with our 3-Mirror, no flange gonio lens.
17
G-1 Gonio
1-Mirror, All-Glass Design
• High magnification (1.50x) enables detailed viewing of the trabecular meshwork
• All-glass design provides superior clarity and durability
• Available in two formats: flanged (recommended for laser trabeculoplasty) and no flanged
(recommended for routine gonioscopy)
Product code:
Flange: VG1 (as shown)
62°
No Flange: VG1NF
Product code:
Flange: VG2 (as shown) 60°
No Flange: VG2NF
64°
Gonio Lenses
G-3 Gonio 2D View
3-Mirror, All-Glass Design
• 60˚ mirror provides a view of the iridocorneal angle
• 66˚ mirror provides a retinal image from the equator to the ora serrata
• 76˚ mirror provides a view of the mid-peripheral/peripheral retina
• Available in two formats: flanged (recommended for laser trabeculoplasty) and no flanged
(recommended for routine gonioscopy)
Product code:
Flange: VG3
No Flange: VG3NF (as shown) 66°
Gonio Mini, No Flange: VG3MININF (as shown)
60°
Available in mini version for 76°
pediatric and patients with small orbits
2D View
3-Mirror
Primary Application – 3-Mirror, Acrylic Design
• 3-mirror design provides the same views as our G-3 Gonio lenses but in a light weight acrylic design
• Uncoated lenses are ideal for diagnostic exams while coated lenses are perfect for laser treatments
• Advanced no fluid (ANF+) flange only requires a coupling fluid during laser procedures
Product code:
No Flange: V3MIR (as shown)
ANF+ Flange: V3MIRANF+ 66°
No Flange, No Coating (Diagnostic): VU3MIR 60°
ANF+ Flange, No Coating (Diagnostic): VU3MIRANF+
76°
2D View
18
G-4 Gonio
4-Mirror, All-Glass Design
• 4-mirror design allows for comprehensive examination and treatment of the trabecular meshwork
with minimal lens rotation
• Available with a large ring (28.5 mm), a small ring (25.5 mm), or a 2-position handle (right/left handed)
• No flange version is ideal for dynamic and indentation gonioscopy while flanged version provides stability
for laser trabeculoplasty
Product code:
With Flange: VG4 (as shown)
No Flange, Small Ring (25.5 mm): VG4SNF
No Flange, Large Ring (28.5 mm): VG4LNF 4 x 64°
No Flange, Extended Handle: VG4HAN2
2D View
2D View
Mini 4-Mirror
4-Mirror, Acrylic Design
• Smaller, lighter-weight design facilitates easy manipulations within the orbit
• Advanced no fluid (ANF+) flange does not require coupling fluid during routine gonioscopy
Product code:
V4MANF+
Product code:
No Flange, Large Ring (28.5 mm):VG6LNF 6 x 63°
2D View
19
Surgical Gonio Lenses
VVG Lens
Primary Application – Direct Views for Micro-Invasive Glaucoma Surgery (MIGS)
and all Intraoperative Gonio Procedures
• Stabilization ring provides control of the globe
• Minimizes corneal pressure to prevent anterior chamber distortion
• Visualizes angle in primary phaco position with minimal microscope and head adjustments
• Fully steam sterilizable
Product code:
VTSTVG
Gonio Lenses
2D View
Product code:
VSGACS
2D View
20
Single-Use Laser & Gonio Lenses
SINGLE-USE
Experience unmatched image quality and focusing capability with Volk’s single-use laser and gonio lenses. Single-use lenses are
perfect for routine examination, laser treatments, and surgical procedures.
Volk’s single-use lenses are pre-sterilized and individually-packaged in a Tyvek® pouch. Single-use lenses are sold in boxes of 10.
2D View
Single-Use Laser & Gonio Lenses
2D View
Note : Capsulotomy and Iridotomy lenses are suitable for argon, diode and YAG laser treatments.
2D View
Volk®1 Single-Use 3-Mirror Gonio
Primary Application – Gonioscopy and Examination of the Central and Peripheral Fundus
• 60˚ mirror provides a view of the iridocorneal angle
• 66˚ mirror provides a retinal image from the equator to the ora serrata
• 76˚ mirror provides a view of the mid-peripheral/peripheral retina
Product code:
V3MIRD10
2D View
Volk®1 Single-Use 4-Mirror Gonio
Primary Application – Static and Dynamic Gonioscopy
• Four-mirror design allows for comprehensive examination and treatment of the
trabecular meshwork with minimal lens rotation
Product code:
V4MIRD10
21
2D View
IMAGING
Imaging
22
Portable Retinal camera
23
iPhone fundus camera
iNview
power and convenience of the Apple iPhone with the
trusted quality of Volk optics.
24
SURGICAL
25
MERLIN® Surgical System
The unique design of the Lens Positioning Unit (LPU) is precisely aligned to the optical axis of the
microscope and offers a simple pivoting mechanism that folds away when not in use. An intuitive
fine focus wheel provides smooth, graduated adjustment to optimally position the lens.
26
Reinverting Operating Lens System® (ROLS®)
The ROLS® is an advanced panoramic viewing system that provides reinverted viewing during vitreoretinal
surgery, delivering high resolution, direct retinal images. ROLS® is compatible with all surgical microscopes
for viewing the retina with indirect contact surgical lenses and the MERLIN non-contact surgical viewing
system.
ROLS® ∞ (Infinity)
The ROLS∞ is our newest reinverter and provides superior image quality with minimal image shift. It is
available in manual and powered versions. The powered version works with the Merlin surgical system,
engaging automatically when the LPU is pivoted into place. The powered version can also be operated by
an available footswitch.
27
Surgical Vitrectomy Lenses
Volk offers a variety of vitrectomy lenses over a range of optical profiles and efficiently built to cater to
various vitrectomy procedures.
Surgical Lenses
Field of View
130° / 150°
Product code:
VHRXVIT
Self Stabilizing: VHRXVITSSV (as shown) 130°
150°
Mini Quad® XL
Primary Application – Indirect Viewing and Treatment of Peripheral Retinal Disorders
• Wide field of view of the entire retina including the ora serrata
• Ideal for retinal detachments and giant retinal tears
• Available in standard and self stabilizing contact (SSV®) options
Field of View
112° / 134°
Product code:
VMQXLVIT (as shown)
Self Stabilizing: VMQXLVITSSV
134°
112°
28
Mini Quad®
Primary Application – Indirect Viewing and Treatment of Peripheral Retinal Disorders
• Wide field of view of the entire retina including the ora serrata
• Smaller ring facilitates manipulation within the orbit
• Ideal for retinal detachments and giant retinal tears
• Available in standard and self stabilizing contact (SSV®) options
• Available in autoclave sterilizable design (see page 33)
Field of View
106° / 127°
Product code:
VMQVIT (as shown)
Self Stabilizing: VMQVITSSV
127°
106°
Field of View
95° / 127°
Product code:
VDVVIT
127°
95°
Surgical Lenses
Central Retinal
Primary Application – High Magnification Indirect Viewing and Treatment of the Central Retinal
• High resolution, high magnification imaging to the equator
• Ideal for membrane peeling, retinal tears and other small detail procedures
• Available in standard and self stabilizing contact (SSV®) options
• Available in autoclave sterilizable design (see page 33)
Field of View
73° / 88°
Product code:
VCRLVIT (as shown)
Self Stabilizing: VCRLVITSSV 88°
73°
Super Macula®
Primary Application – Highest Magnification Indirect Viewing and Treatment of the Central Retinal
• High resolution, highest magnification imaging of the central retina
• Ideal for macular holes, epiretinal membranes, and submacula surgery
• 2x field of view compared to plano/concave direct image lenses
Field of View
64° / 77°
Product code:
VSMACVIT
77°
64°
29
High Resolution (HR)
Direct Image Surgical
Vitrectomy Lenses
Volk’s high resolution direct image lenses utilize a high index glass to deliver superior
image quality. This robust glass type is highly resistant to the rigors of continued steam
sterilization and will not deteriorate or discolor.
Volk’s No Stabilizing Ring (NSR) range of lenses allow suitable stability without the need for
suturing or stabilizing rings. Two of the lenses in the group are also available in a no suture
ring design. The profiles of these two lenses allows them to stabilize suitably without the
need for an additional stabilizing ring.
Surgical Lenses
30
HR Direct 1x
Primary Application – Direct Image Vitreoretinal Surgery of the Central Retina
• High index glass delivers highest resolution direct image of the central retina
• Highly suited for repeated steam sterilization with no material degradation
1X • Standard design fits all major suture rings
• Unique optional no stabilizing ring (NSR) design available
Field of View
30°
1X (NSR) Product code: 30°
Stabilizing Ring: VHRD1XACS
No Stabilizing Ring: VHRD1XNSRACS
Field of View
High Mag (NSR) Product code: 20°
20°
Field of View
40°
40°
Product code:
VHRD20PACS
20°
31
Autoclavable
Surgical BIO Lenses
Combine the optical excellence of Volk lenses with the comfort of reduced processing time in a
surgical environment with the autoclavable lens line.
Laser Working
Lens Field of View Image Mag.
Spot Mag. Distance
20D ACS® 46° / 60° 3.13x 0.32x 50 mm
28D ACS® 53° / 69° 2.27x 0.44x 33 mm
20D ACS®
Primary Application – Industry Standard Diagnostic Lens in an Autoclavable Format
• Steam sterilizable for use in a surgical environment
Field of View
46° / 60°
Product code:
V20LCACSPV
60°
46°
Field of View
53° / 69°
Product code:
V28LCACSPV 69°
53°
53° / 69°
32
Autoclavable
Surgical Vitrectomy Lenses
Lens Field of View Image Mag.
HRX ACS® 130° / 150° 0.43x
Mini Quad® ACS® 106° / 127° 0.48x
Central Retinal ACS® 73° / 88° 0.71x
HRX ACS®
Primary Application – Widest Field Views for Vitreoretinal Procedures
• Superior high index glass design ensures widest field views of any vitrectomy lens
• Advanced aspheric design provides unmatched high resolution imaging
53° / 69°
• Steam sterilizable for reduced processing time
ACS® Indirect BIO & Surgical Lenses
Field of View
130° / 150°
VHRXVITSSVACS
Field of View
106° / 127°
33
Direct Surgical Vitrectomy Lenses
(Self Stabilizing)
Volk’s surgical vitrectomy lens designs were developed with K.V.Chalam, MD. The self stabilizing
vitrectomy (SSV®) ACS® contact design eliminates the need for suture rings.
Field of View
30°
30°
Product code:
VFLATSSVACS
Field of View
28°
28°
Product code:
VFHMSSVACS
Field of View
40°
40°
Product code:
VMFSSVACS
Field of View
30° 30°
Product code:
VPRISMSSVACS
15°
Field of View
30°
30°
Product code:
V30PRISMSSVACS
30°
Direct Surgical Lenses
Field of View
30°
30°
Product code:
V45PRISMSSVACS
45°
Field of View
30°
30°
Product code:
VAFXSSVACS
35
SINGLE-USE
Single-use lenses are pre-sterilized and individually-packaged in a Tyvek® pouch. Single-use lenses are sold in
boxes of 10.
Field of View
45° / 58°
Product code:
V20LCD10
58°
45°
Field of View
54° / 70°
Product code:
V28LCD10
70°
54°
36
SINGLE-USE
Field of View
36°
Product code: 36°
Product code:
Standard: VFD10
VFD10
Self Stabilizing: VFLATSSVD10
Field of View
36°
36°
Product code:
VFLATSSVD10
30°
37
58°
45°
Field of View
30°
30°
Product code:
VMD10
Field of View
48°
48°
Product code:
VWFD10
Field of View
25°
25°
Product code:
VBCD10
Product code:
V30PD10
30°
38
Research Lenses
Part Image Contact Lens Handle
Lens
Number Mag. Diameter Height Length
2 mm Fundus V2MFUNDUS 1.0x 2 mm 5 mm 76 mm
2 mm Gonio V2MGONIO 1.0x 2 mm 11 mm 84 mm
Fundus Lens
Provides high resolution views of the posterior pole. Its upper surface has an A/R coating
to minimize reflections and glare and maximize laser throughput. The contact surface is
conically shaped to facilitate placement and does not require viscous coupling fluid. Its
handle is fixed at 45°.
Volk Accessories
Volk Lens Pen®
Primary Application – Dry Cleaning of Coated Ophthalmic Lens Surfaces
• Carbon based cleaning pad wipes away smudges and reduces static build up
• Cost effective device good for 400–500 uses
• Conveniently stows away like a pen with a pocket clip
Product code:
VLENSPEN
Not for use on surfaces that contact the eye.
Product code:
Box: VPOLC1
Case: VPOLCCASE
39
Steady Mount
Primary Application – Precisely Holds and Positions Volk Lenses at the Slit Lamp
• Holds lenses steady at the slit lamp to facilitate photography and routine examinations
• Lens can be positioned, tilted and angled in all planes providing versatility
• Adapts to all slit lamps and holds all Volk lenses ensuring ease of use
Product code:
VSM
Suture Ring
Primary Application – Provides a Stable Lens Platform During Vitreoretinal Surgery
• Premium surgical implant grade titanium for optimal durability and ease of sterilization
• Larger radius provides enhanced functionality and safety during use
• Compatible with all Volk direct and indirect contact vitrectomy lenses (except SSV® styles)
Product code:
VSRS2
Infusion Handle
Primary Application – Infusion of Saline Solution Beneath the Lens During Vitreoretinal Surgery
• Flushes blood and debris providing a clear view during surgery
• Autoclave sterilizable for reduced processing time
VitreoLens Handle
Primary Application – Holding and Stabilization of Lenses During Vitreoretinal Surgery
• Holds vitrectomy lenses stably to assist vitreoretinal surgery
• Malleability allows user to bend the handle to suit their preference
• Autoclave sterilizable for reduced processing time
Product code:
Mini Quad and Central Retinal: VVITHAN-LG
HRX, Mini Quad XL and Super Macula: VVITHAN-MQXL
Sterilization Tray
Primary Application – Sterilization of Ophthalmic Lenses
• Autoclave safe and approved for use with ETO
• Small tray (2.7” x 1.5” x 1.25”) houses Volk surgical and smaller indirect and slit lamp lenses
• Large tray (6” x 2.5” x 1.25”) houses the largest Volk lenses and accessories including vitrectomy handles
Product code:
Small Tray: VSCA
Large Tray: VSCB
40
Cases and Personalization
Volk’s new single-lens case features a sleek and modern functional design. We’ve incorporated a robust
hinge designed to withstand over 50,000 openings and a magnetic closure that keeps your lens securely
stored within the case.
Research Lenses & Accessories
Engraving
Add a personal touch to your lenses and
single-lens cases by engraving custom
text on them to create a personal
possession that will last a lifetime.
41
Design Options
Patented Double Aspheric Lens Design
All Volk lenses are optically engineered using proprietary computer ray
tracing and design criteria. The laser contact lens ray tracing at left shows
light rays originating at the illuminated fundus and proceeding through the
pupil and cornea to the first contact element. The diverging light bundles
are converged and redirected towards the double aspheric imaging lens
which further refracts and focuses the rays as a conjugate fundus image in
the aerial image plane. From the beginning on the drawing board to final
production and sale, each Volk lens is designed and produced to the quality
standards that your practice demands.
No flange (NF) versions have a small corneal contact area and are excellent for diagnostic work. It may not be
necessary to use a contact fluid with these versions (gonio lenses only)
Technical Specifications
Our exclusive ANF+ flanged version is designed to provide optimal stability without the need for a contact
fluid. It is beneficial to utilize a lubricating fluid for patient comfort.
No flange (NF) versions have a smaller corneal contact area than flanged versions. It is still necessary to use a
contact fluid with these versions.
Our exclusive ANF+ flanged version is designed to provide optimal stability without the need for a contact
fluid. During diagnosis, it may be beneficial to utilize a lubricating fluid for patient comfort. However, during
laser procedures, an appropriate coupling must be used.
42
Warranty Information
Warranty Service
If the product fails to function due to defects in either materials Volk® 1 Single-Use Lenses
or workmanship, Volk will, at its option, either repair or replace Volk Optical warrants its Volk® 1 Single-Use Lenses against
the product without charge, subject to the Warranty Limitations. defects in material and workmanship for the period ending with
the product’s sterility expiration.
Non-Contact Slit Lamp & BIO Lenses
Volk Optical warrants its Non-contact Slit Lamp & BIO Lenses Product Returns
against defects in materials or workmanship for a period of 10 All product returns must be disinfected and/or sterilized
years from receipt by end user. prior to return and be accompanied by a Return
Authorization Number.
Laser & Diagnostic Lenses
Volk Optical warrants its Volk Contact Laser & Diagnostic Please contact Volk Optical for a Return Authorization Number.
Lenses against defects in materials or workmanship for a Customers are responsible for returning products to Volk
period of 5 years from receipt by end user. Optical; 7893 Enterprise Drive; Mentor, OH 44060; U.S.A.
We recommend that all returns be insured and be sent by a
traceable shipment method. Volk cannot be held responsible
G-Series Gonio Lenses for lost shipments.
Volk Optical warrants its All GLASS G-Series Gonio Lenses
against defects in materials or workmanship for a period of 4
years from receipt by end user. Warranty Limitations
Warranty service may not be provided without proof the product
was purchased from Volk Optical Inc. or an authorized Volk
Standard 3 & 4 Mirror Lenses Distributor.
Volk Optical warrants its standard 3 & 4 Mirror Lenses against
defects in materials or workmanship for a period of 1 year from This warranty becomes null and void if the customer fails to
Warranty Information
receipt by end user. return the product in packaging consistent with the original
protective packaging and it results in shipping damage.
2 mm Research Lenses This warranty becomes null and void if the customer fails to
Volk Optical warrants its 2 mm research lenses (fundus and follow the recommended cleaning, disinfection and sterilization
gonio) against defects in materials or workmanship for a period instructions and/or cautions contained in the product instruction
of 1 year from receipt by end user. manual.
43
Ordering Information
4 easy ways to order!
Order Online
v o lk .c om
Order by Phone
4 4 0 .9 4 2 . 6161
8 0 0 .3 4 5 . V OL K (toll free in the USA)
Order by Mail
7 8 9 3 En terp ri se Dri ve
M e nt or, Oh i o 44060, US A
Order Information
Order through your
Authorized Volk Distributor
Follow us online
44
Volk Optical Inc.
7893 Enterprise Drive
Mentor, OH 44060
volk.com
[email protected]
ML-1001
Copyright © 2019 Volk Optical Inc.
Rev. Feb. 2019