NI 9205
16 AI Differential/32 AI Single-Ended, ±200 mV to ±10 V, 16 Bit,
250 kS/s Aggregate
The NI 9205 is a C Series module for use with any CompactDAQ or CompactRIO system.
Each channel has programmable input ranges of ±200 mV, ±1 V, ±5 V, and ±10 V. To protect
against signal transients, the NI 9205 includes ±30 V of overvoltage protection between input
channels and common (COM). In addition, the NI 9205 also includes a channel-to-earth-
ground double isolation barrier for safety, noise immunity, and high common-mode voltage
range. The NI 9205 is rated for 1,000 Vrms transient overvoltage protection.
• NI 9205
Kit Contents
• NI 9205 Getting Started Guide
Screw-Terminal
• NI 9940 Backshell Kit (779567-01)
DSUB
Accessories
Front-Mount
• NI 9923 Screw-Terminal Block (780179-01)
Cable
• DSUB Cable, 1 m (778621-01)
32 Single-Ended,
NI 9209 ±10 V 500 S/s No 24-Bit DSUB
16 Differential
Screw-Terminal,
NI 9215 ±10 V 4 Differential 100 kS/s/ch Yes 16-Bit Spring-Terminal,
BNC
Spring-Terminal,
NI 9220 ±10 V 16 Differential 100 kS/s/ch Yes 16-Bit
DSUB
Screw-Terminal,
NI 9221 ±60 V 8 Single-Ended 800 kS/s No 12-Bit Spring-Terminal,
DSUB
Screw-Terminal,
NI 9222 ±10 V 4 Differential 500 kS/s/ch Yes 16-Bit
BNC
Screw-Terminal,
NI 9223 ±10 V 4 Differential 1 MS/s/ch Yes 16-Bit
BNC
NI provides more than 100 C Series modules for measurement, control, and communication
applications. C Series modules can connect to any sensor or bus and allow for high-accuracy
measurements that meet the demands of advanced data acquisition and control applications.
• Measurement-specific signal conditioning that connects to an array of sensors and signals
• Isolation options such as bank-to-bank, channel-to-channel, and channel-to-earth ground
• -40 °C to 70 °C temperature range to meet a variety of application and environmental
needs
• Hot-swappable
The majority of C Series modules are supported in both CompactRIO and CompactDAQ
platforms and you can move modules from one platform to the other with no modification.
CompactRIO
CompactRIO combines an open-embedded architecture
with small size, extreme ruggedness, and C Series
modules in a platform powered by the NI LabVIEW
reconfigurable I/O (RIO) architecture. Each system
contains an FPGA for custom timing, triggering, and
processing with a wide array of available modular I/O to
meet any embedded application requirement.
CompactDAQ
CompactDAQ is a portable, rugged data acquisition platform
that integrates connectivity, data acquisition, and signal
conditioning into modular I/O for directly interfacing to any
sensor or signal. Using CompactDAQ with LabVIEW, you
can easily customize how you acquire, analyze, visualize,
and manage your measurement data.
Input Circuitry
The NI 9205 channels share a common ground that is isolated from other modules in the
system. All channels share a programmable gain instrumentation amplifier and are multiplexed
to an ADC. Each channel also has ±30 V overvoltage protection.
Trig
AI+ Trigger
AISENSE 16-bit
Filtered Isolated
COM Differential ADC
Amplifier
NI 9205
NI 9205 Specifications
The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted.
All voltages are relative to COM unless otherwise noted.
Caution Do not operate the NI 9205 in a manner not specified in this document.
Product misuse can result in a hazard. You can compromise the safety protection
built into the product if the product is damaged in any way. If the product is
damaged, return it to NI for repair.
AI <0...31> CMRR
140
120
100
CMRR (dB)
80
60
40
60 100 1k 10 k 100 k
Frequency (Hz)
Absolute accuracy
±10 V range
Accuracy at full scale1 6,230 μV
Random noise, σ 240 μVrms
Sensitivity2 96.0 μV
±5 V range
Accuracy at full scale1 3,230 μV
Random noise, σ 116 μVrms
Sensitivity2 46.4 μV
±1 V range
Accuracy at full scale1 690 μV
Random noise, σ 26 μVrms
Sensitivity2 10.4 μV
±0.2 V range
Accuracy at full scale1 174 μV
Random noise, σ 10 μVrms
Sensitivity2 4.0 μV
Residual gain error
±10 V range 115 ppm of reading
±5 V range 135 ppm of reading
±1 V range 155 ppm of reading
±0.2 V range 215 ppm of reading
Gain tempco 11 ppm/°C
Reference tempco 5
1 Absolute accuracy values at full scale on the analog input channels assume the device is operating
within 70 °C of the last external calibration and are valid for averaging 100 samples immediately
following self-calibration.
2 Sensitivity is a function of noise and indicates the smallest voltage change that can be detected.
Absolute accuracy at full scale on the analog input channels is determined using the following
assumptions:
Temp Change from Last External Cal = 70 °C
Temp Change from Last Internal Cal = 1 °C
Number of Readings = 100
Coverage Factor = 3 σ
For example, on the ±10 V range, the absolute accuracy at full scale is as follows:
Gain Error = 115 ppm + 11 ppm * 1 + 5 ppm * 70
Gain Error = 476 ppm
Offset Error = 20 ppm + 44 ppm * 1 + 76 ppm
Offset Error = 140 ppm
Noise Uncertainty = (240 μV * 3) / √100
Noise Uncertainty = 72 μV
Absolute Accuracy = 10 V * 476 ppm + 10 V * 140 ppm + 72 μV
Absolute Accuracy = 6,232 μV, rounds to 6,230 μV
Power Requirements
Power consumption from chassis
Active mode 625 mW maximum
Sleep mode 15 mW
Thermal dissipation (at 70 °C)
Active mode 625 mW maximum
Sleep mode 15 mW
3 The digital input and digital output channel are supported only in FPGA Interface mode in
software.
Spring-terminal wiring
Gauge 0.8 mm2 to 1.0 mm2 (28 AWG to 18 AWG)
copper conductor wire
Wire strip length 7 mm (0.276 in.) of insulation stripped from
the end
Temperature rating 90 °C minimum
Wires per spring terminal One wire per spring terminal
Connector securement
Securement type Screw flanges provided
Torque for screw flanges 0.2 N · m (1.80 lb · in.)
Weight
NI 9205 with spring terminal 158 g (5.8 oz)
NI 9205 with DSUB 148 g (5.3 oz)
Safety Voltages
Connect only voltages that are within the following limits:
Maximum voltage4
Channel-to-COM ±30 VDC
4 The maximum voltage that can be applied or output between AI and COM without creating a safety
hazard.
5 This specification is valid only up to 2,000 m.
Caution Do not connect the NI 9205 to signals or use for measurements within
Measurement Categories II, III, or IV.
Hazardous Locations
U.S. (UL) Class I, Division 2, Groups A, B, C, D, T4;
Class I, Zone 2, AEx nA IIC T4
Canada (C-UL) Class I, Division 2, Groups A, B, C, D, T4;
Class I, Zone 2, Ex nA IIC T4
Europe (ATEX) and International (IECEx) Ex nA IIC T4 Gc
Note For UL and other safety certifications, refer to the product label or the Online
Product Certification section.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards of EMC for
electrical equipment for measurement, control, and laboratory use:
• EN 61326 EMC requirements; Industrial Immunity
• EN 55011 Emissions; Group 1, Class A
• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note For EMC compliance, operate this device with shielded cabling.
CE Compliance
This product meets the essential requirements of applicable European Directives, as follows:
• 2014/35/EU; Low-Voltage Directive (safety)
• 2014/30/EU; Electromagnetic Compatibility Directive (EMC)
• 94/9/EC; Potentially Explosive Atmospheres (ATEX)
Operating vibration
Random (IEC 60068-2-64) 5 grms, 10 Hz to 500 Hz
Sinusoidal (IEC 60068-2-6) 5 g, 10 Hz to 500 Hz
Operating shock (IEC 60068-2-27) 30 g, 11 ms half sine; 50 g, 3 ms half sine;
18 shocks at 6 orientations
Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible
manner. NI recognizes that eliminating certain hazardous substances from our products is
beneficial to the environment and to NI customers.
For additional environmental information, refer to the Minimize Our Environmental Impact
web page at ni.com/environment. This page contains the environmental regulations and
directives with which NI complies, as well as other environmental information not included in
this document.
电子信息产品污染控制管理办法(中国 RoHS)
中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物
质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信息,请登录
ni.com/environment/rohs_china。(For information about China RoHS
compliance, go to ni.com/environment/rohs_china.)
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product and
company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI
products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the
National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs)
and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/
legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other
import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION
CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in
this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth
in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.
374188A-02 Oct15