0% found this document useful (0 votes)
383 views2 pages

2020HR Specification Sheet

Uploaded by

Dave
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
383 views2 pages

2020HR Specification Sheet

Uploaded by

Dave
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

To buy, sell, rent or trade-in this product please click on the link below:

http://www.avionteq.com/Aces-2020HR-ProBalancer-Propeller-Balancer-Analyzer.aspx

Balancing and Spectrum Analysis Made Fast, Simple and Affordable


Model www.avionteq.com

ProBalancer

Dynamic Balancing
Rotor Track and Balance
Spectrum Analysis
High Resolution Screen

Turbo is standard on ACES Model 2020HR


ProBalancer Analyzer
320x240 high resolution screen The ACES Model 2020HR ProBalancer Analyzer combines
the best features of previous ProBalancers with the
Full time adjustable contrast keys while
spectrum analysis capabilities of our top-of-the-line ACES
analyzer is on
Analyzers. The new higher resolution screen with its
True multiple-channel, simultaneous inputs easier to read, white LED backlite feature allows brighter,
Full graphic spectrum display with cursor and sharper, at-a-glance visuals. The high capacity recharge-
expanded-view feature able battery and ship’s power input permit you to operate
indefinitely without downtime for changing or recharging
Backlit easier to read white graphic LCD screen the battery, thus increasing productivity.
Digital accuracy
This ultra-efficient instrument, designed with direct input
5-year warranty from customers, offers more functionality, more accuracy,
Step-by-step propeller balance and speed of use than ever before. Responsive to custom-
ers’ needs, our team of innovative engineers have added
Programmable propeller balance influences many other new user-convenience features that could
Maintains prior influences to compute one-shot make the Model 2020HR the star of the ProBalancer line.
balance With its true, two-channel simultaneous inputs, the Model
2020HR makes performing twin engine propeller balanc-
Split weights to existing holes
ing a snap. In addition, it acquires both vertical and
Helicopter magnitude and phase measurements lateral helicopter main rotor vibration measurements
Supports the use of multiple speed and without switching channels which is infinitely more time
vibration sensor types such as: strobe, tracker, and fuel efficient.
phototach, Lasetach®, magnetic interrupter, The Model 2020HR ProBalancer Analyzer provides step-
accelerometers, velocimeters, etc. by-step on-screen instructions for performing propeller
User-defined and stored setups for repeated use balancing, rotor track and balance measurements, and
vibration surveys. Additionally, the user may extend the
Printouts of all jobs and setups
basic capabilities by defining and saving “setup informa-
Powered by internal battery or ship's power tion” for common procedures. These saved settings can be
Large, easy-to-read multiple-function keypad recalled later to provide on-screen setup information,
consistent procedures, and one-shot balance solutions
Compact, rugged design without the difficulty of configuring the unit and re-
entering data each time you use it. Once you complete a
Easy, Detailed, Time-Efficient job, it is easy to print a summary of the job suitable for log
Vibration Analysis and Balancing book entry. The rugged construction, with its expanded
Simultaneous Data Input, Full Graphical Display, and ABS plastic case, continues the ACES tradition of high
Custom Setups quality, durable vibration test equipment for years of
trouble-free operation.
ACES Systems/TEC Aviation Division
ACES
R

10737 Lexington Dr., Knoxville, TN 37932 USA . Ph. 865.671.2003, Fax 865.675.1241 Creating better aviation maintenance solutions...
ISO 9001 Certification . www.acessystems.com S Y S T E M S
Model 2020HR
ProBalancer
Technical Specifications
Accuracy
Vibration Amplitude: +/- 5%, 0 - 10 IPS
Frequency Range: 0 - 10K Hz
Tachometer Inputs: +/- .3%, 100 - 10,000 rpm
Power Supply
Camcorder Type Battery Model RB 85 or Equivalent
(12V, 2.3 A hour internal lead acid battery)
Operation Time
Up to 10-12 hours
Voltage
12 V DC Battery or 14-28 V DC ships power Complete Propeller Balance Kit:
Model 2020HR ProBalancer Analyzer Prop Protractor - Full Circle
Charging Time Battery
991D-1 Vibration Sensor Charger
2 hours 25' Vibration Sensor Cable Pocket Pro Tackle Box
Physical Specifications Phototach Speed Sensor Communications / Printer Cable

Height: 9.3" 25' Tachometer Sensor Cable Training Video


Phototach Mount Assembly Carrying Case
Width: 7.5"
1/4 x 28 Vibration Sensor Mount User's Manual
Depth: 4.4" Eight piece case-bolt adapter set FAA-Approved ACES Guide to
Weight: 4.8 lbs. Digital Gram Scale Propeller Balancing
AC Input
Optional interfaces are available for a wide range of vibration and speed sensors
The data acquisition system is capable of measuring AC values
from 0.1 volt to 2.048 volts peak. The full graphics capability of the Model 2020 The ACES Model 2020HR ProBalancer
presents data in an easy-to-interpret format. As in
Tachometer-Synchronized Measurements the example screen, the IPS and clock functions
Analyzer's ability to display two channels
at once allows you to perform front and
The analyzer can use the tachometer input to synchronously appear in a “thermometer” format for easy viewing. rear engine vibration analysis or vertical
sample and average data. These data contain phase information and lateral analysis for rotary wing
for vibration related to the tachometer. The analyzer can report applications. Cursor functions allow you
phase to +/- 3 degrees for this vibration, which is reproducible to to examine detailed frequency data.
1 degree.
Unconditioned Tachometer Input
Tachometer signal processing electronics are capable of adjusting
the full-scale input range to handle any available sensor for
measuring speed. Adjustment of the tachometer conditioning
electronics is performed automatically by the microprocessor and
requires no user intervention. The voltage level that is used as a
reference for detection of the start of the revolution can be
adjusted from 120mV to 5 volts. The tachometer circuitry can
detect speeds up to 10,000 RPM.
Autoranging Input Each review screen contains all the
The analyzer autoranges all signal inputs based on sensor information required to make adjustments
sensitivity. That way, it can determine the optimum gain setting to to your job. The run number, condition,
vibration amplitude/clock angle, and blade
achieve the maximum dynamic range. Gains are adjusted by tracking information are recorded and
factors of two (1 to 512) for all channels. This adjustment enables readily available for viewing, printing, or
the analyzer to perform each measurement without overload and storage with only a few keystrokes.
with maximum accuracy.
Sensor Types High Quality ACES Systems products are manufactured at the TEC
The analyzer will accept any vibration signal input (acceleration, facility in Knoxville, Tennessee. Our aviation products are manufactured to
velocity, or displacement). The input is then displayed as collected ISO 9001 standards and guaranteed for five years against defects in material
or integrated to an other vibration unit. The vibration input will and workmanship. Extensive testing and quality checks are performed before
accept any voltage-generating sensor (must have external charge any ACES product is allowed to leave the factory. At ACES, total Quality is not a
converter when in charge mode) and will supply power to the “buzzword,” it is the foundation of our business.
sensor when required.
ACES Systems/TEC Aviation Division
Analysis Range
10737 Lexington Drive, Knoxville, TN 37932 USA
A high roll-off, 8-pole elliptical, anti-aliasing filter is used with a
Fast Fourier Transform (FFT) to accurately transform data from Telephone 865.671.2003, Fax 865.675.1241
the time to the frequency domain. The analyzer will perform FFT ISO 9001 Certification . www.acessystems.com
resolutions of 100, 200, 400, and 800 lines.

ACES
R

Creating better aviation maintenance solutions...


Copyright 2002, 2005 TEC - All Rights Reserved - Specifications Subject to Change Without Notice S Y S T E M S