0% found this document useful (0 votes)
208 views11 pages

Rooftop Packaged Air Conditioners: - URTP 055-230 - URTP 280-460

Rooftop packaged air conditioners ranging from 31.9 kW to 262 kW are described. They have options for natural gas heating, free cooling, and advanced controls. The units are designed for applications such as malls, warehouses, offices, and cinemas.

Uploaded by

ayan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
208 views11 pages

Rooftop Packaged Air Conditioners: - URTP 055-230 - URTP 280-460

Rooftop packaged air conditioners ranging from 31.9 kW to 262 kW are described. They have options for natural gas heating, free cooling, and advanced controls. The units are designed for applications such as malls, warehouses, offices, and cinemas.

Uploaded by

ayan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Rooftop Packaged Air Conditioners

• URTP 055-230
• URTP 280-460

DIRECT
DIRECT GAS FIRED
OPTION
Rooftop Packaged Air Conditioners

4 Seasons Smart Rooftop Packaged Air Conditioners


Varying a wide capacity range, Untes Packaged Rooftop Units have been exclusively designed mainly for large spaces such as
shopping malls, conference and cinema halls, warehouses etc. produced for quick installation, low operating costs, the flexibility of
cooling, heating and pressure options and more to discover.

Advanced controls options also provide flexibility and signify connectivity and intelligence to the whole building management
system having the controls embedded and can communicate seamlessly to all controls systems.

On-board controls support the entire network, includes fault detection and support proactive maintenance and minimize downtime of
the system for business contiunity as well as the best efficiency, extended equipment life and reduced operating costs.

Roof Top Package Air Conditioners


Flexible Package Air Conditioning Solutions
High Energy Efficient Roof Top Package Air Conditioners
Eco friendly R410A Refrigerant Gas
Gas Fired Condensing Heating Option
Three Step Capacity Control by Uneven Cooling / Heating
Advanced Microprocessor Control

Compactness with Well Qualified Air


Optimal Energy Efficiency, Air Quality and Comfort
Wide and Versatile Range
Integrated Freecooling Options
Energy Saving Solutions for All Commercial Buildings

1
Rooftop Packaged Air Conditioners

Range Type Version Presure Class Model

URTP BSC
ECO
SS : Cooling Only
HP : Heat Pump
YB : High Pressure
OB : Medium Pressure
055~460

Airflow Configurations
URTP 055-230 BSC

URTP 055-230 ECO

URTP 280-460 BSC-ECO

2
Rooftop Packaged Air Conditioners

Options / Accessories

BRCA: Downflow Roof Curb [055-230] EBDD: Exhaust Backdraft Damper MIIM: Microprocessor Additional Module

BRCY: Sideflow Roof Curb [055-230] DGYI: Direct Gas Heater OFKI: Dirty Filter Warning

FRCA: Downflow Roof Curb EIDK: Low Capacity Electrical Heater


+ Return Fan [055-230] EIYK: High Capacity Electrical Heater IUDK: Indoor Fan Airflow Control

FRCY: Sideflow Roof Curb


SSIB: Hot Water Heating Coil IHKS: Indoor Air Quality Sensor (CO2)
+ Return Fan [055-230]

PEFA: Power Exhaust Fan [055-230] FCEC: Enthalpy Control For ECO Type DDYA: Smoke Detector

3
Rooftop Packaged Air Conditioners

Due to its elegant and ergonomic design, Rooftop units are the most ideal
air treatment units for shopping malls, warehouses, offices, cinemas and
large spaces . Its compact design perfectly suits all types of places in
terms of decoration. BSC and ECO types offer smart air conditioning
solutions to the customers.

Freecooling
Irreplaceable air treatment units of big volume places, the rooftop air conditioners
are reinterpreted according to the requirements of our modern era. URTP model
rooftop air conditions are designed as two main ranges:

• Package type BSC range responds basic unit requirements and package
type ECO range based on energy saving.

• Both ranges offer wide solution alternatives for users with only cooling or
heat pump options.

Air Control
• Outstanding air flow control due to inverter control silent plug fan.
• Three different external static pressure option.
• Manual fresh air damper control (BSC)

Roof Curbs
It offers solutions for all kinds of construction problems with its different
connection equipment. Due to this specification, unit can be adapted without
making ancy changes or modifications in the construction. Axial fan/ without
axial fan, bottom inlet- bottom outlet connections. In addition to all these, the
unit also offers automatically controlled fresh air and exhausts air damper as
well as fresh air and exhaust air rain resistant solutions.

Heating & Cooling


Eco-friendly R-410A refrigerant gas is used in the unit. The unit offers two
independent gas circuits with “Cooling Only” and “Heat Pump” options. These
asymmetrically designed circuits allow 3 steps capacity control [055-230]. Larger
capacity units, there is 4 steps capacity control with tandem connection [280-460].
Three alternatives are offered for heating, namely “Natural Gas Heating
(condensed and modulated)”, “Electric Heater (multi-phased)” and “Hot Water”. All
problems are solved and due to whole heating solutions, all heating problems are
responded.

4
Rooftop Packaged Air Conditioners

Fans
Inverter controlled silent plug fans are used in inside air part. This specification
offers different outside unit static pressure options by conducting flow control.
Meanwhile, high energy efficiency, silent version axial fans are used for outside unit
condenser cooling. This part is specially designed and submerged in the unit. High
capacity plug fans used in ventilators eliminates the necessity of aspirator fans
needed in the classical systems. For fresh air, “power exhaust fan” option is
available for undesired positive pressure situations.

Economizer (Free Cooling)


ECO range of URTP units offers “Thermic” or “Entalphy” control
options that allows energy efficiency and reduce noise pollution by
average outside air support during mid-seasons. As an option, “Return
Fan” or “Support Exhaust Fan” choices are offered.

5
Rooftop Packaged Air Conditioners

URTP Series
URTP 055-230
31,9 kW - 130,1 kW 35,5 kW - 143,1 kW

URTP 280-460
165,0 kW - 262,0 kW 180,5 kW - 284,0 kW

✓ Natural Gas Heating Option.


✓ High Energy Efficiency
✓ Eco Friendly R410A Refrigerant Gas
✓ Integrated Free-cooling Option
✓ Advanced Microprocessor Control Option

DIRECT
DIRECT GAS FIRED
OPTION

GENERAL FEATURES OPTIONS / ACCESSORIES

Construction and Panel: Corrosion Resistant Self-supported Frame • Gas Heater


Sheet Metal Material: Galvanized Steel • Electric Heater
Thermal and Acoustic Insulation: High Performance Acoustic • Hot Water Heating Coil
Insulation • Roof Curb
Refrigerant Control: Thermostatic Expansion Valve • Return Fan
Heating: Heat Pump / Gas Heater / Hot Water / Electric Heating • Power Exhaust Fan
Heating / Cooling Coil: Copper Pipe Aluminum Fin Hydrophilic • F7 Filter
Exchanger • Condenser Fan Speed Control
Fan: VFD Control Plug Fan • Epoxy Coating
Pressure: High / Low Pressure Gauge • CO2 Sensor
Energy Efficiency: Free-cooling Option (Thermic / Enthalpy Free- • Smoke Detector
cooling) • Humidity Sensor
Power and Regulation: Built-in Power and Control Panel • Maintenance Warning
Monitor / Management: BMS Management • Dirty Filter Warning
• Condenser Protection Grill
• Fresh Air / Exhaust Air Rain Protection
TYPES

• BSC - Basic
• ECO - Free-cooling (Economizer)

VERSIONS

• SS – Cooling Only
• HP – Heat Pump

6
Rooftop Packaged Air Conditioners

055~230
URTP Series
055 070 090 110 140 180 230
Technical Specifications
Supply Airflow m3/h 5.500 7.000 9.000 11.000 14.000 18.000 23.000
External Static Pressure Pa 850 850 950 750 800 750 700
❶ Total Cooling Capacity kW 31,5 38,8 51,8 60,7 79,8 102,0 130,1
Total Absorbed Power (Cooling) kW 17,0 20,8 29,0 32,2 41,9 51,6 65,9
❷ EER 2,83 2,86 2,94 2,86 2,96 2,85 2,75
❸ Heating Capacity (Heat Pump) kW 35,3 43,7 56,4 67,1 87,5 111,2 142,4
Total Absorbed Power (Heating) kW 17,0 20,8 29,0 32,2 41,9 51,6 65,9
❷ COP 3,19 3,24 3,50 3,44 3,48 3,44 3,38
Heating Options
Gas Heater Capacity kW 33,6 33,6 62,9 62,9 80,0 97,2 97,2
❹ Electric Heater Capacity kW 34,0 43,0 55,0 67,0 85,0 110,0 140,0
❺ Hot Water Coil Capacity kW 47,8 54,5 80,6 90,1 130,2 155,5 207,1
Cooling Circuit
Refrigerant Gas R410a R410a R410a R410a R410a R410a R410a
Type of Compressor Scroll Scroll Scroll Scroll Scroll Scroll Scroll
Compressor(s) / Step(s) 2/3 2/3 2/3 2/3 2/3 2/3 2/3
Cooling Circuit 2 2 2 2 2 2 2
Sound Information
➏ Sound Power Level dB(A) 81 82 84 84 83 84 85
➐ Sound Presure Level dB(A) 59 60 62 62 61 62 63
Dimensions
Height (H) mm 1.382 1.382 1.382 1.382 1.382 1.582 1.582
Width (W) mm 1.865 1.865 2.335 2.335 2.991 2.991 3.850
Depth (D) mm 1.735 1.735 1.950 1.950 2.164 2.164 2.295
Weight* kg 755 815 910 955 1.204 1.534 1.794

280~460
URTP Series
280 345 410 460
Technical Specifications
Airflow m3/h 28.000 34.500 41.000 46.000

External Static Pressure Pa 800 800 760 760


❶ Cooling Capacity kW 165,0 201,7 233,4 262,0
Total Absorbed Energy (Cooling) kW 82,6 103,5 117,8 131,1
❷ EER 2,95 2,86 2,86 2,95
❸ Heating Capacity (Heat Pump) kW 180,5 223,7 252,3 284,0
Total Absorbed Energy (Heating) kW 82,6 103,5 117,8 131,1
❷ COP 3,39 3,30 3,04 3,22
Heating Options
Gas Heater Capacity kW 160,0 194,4 194,4 291,6
❹ Electric Heater Capacity kW 130,0 160,0 190,0 210,0
❺ Hot Water Heating Capacity kW 256,5 305,3 356,6 401,8
Cooling Circuit
Refrigerant Gas R410a R410a R410a R410a
Type of Compressor Scroll Scroll Scroll Scroll
Compressor(s) / Steps(s) 4/4 4/4 4/4 4/4
Cooling Circuit 2 2 2 2
Sound Information
➏ Sound Power Level dB(A) 87 86 86 85
➐ Sound Presure Level dB(A) 65 64 64 63
❽ Dimensions
Height (H) mm 1.960 2.160 2.160 2.360
Width (W) mm 4.795 5.185 5.605 5.980
Depth (D) mm 2.300 2.300 2.300 2.300

❶ Outside air temperature 35 °C DB, coil inlet temperature is 27 °C DB/19 °C WB. ❻ Measurements compatible with UNI EN-ISO 9614 are basically
❷ COP and EER values are calculated according to EN14511 standard. dB(A) type total sound power level.
Mentioned values are at average pressure values. ➐ Measured in free area, 5 meters away from the unit.
❸ Outside air temperature 7 °C DB, coil inlet temperature is 20 °C DB. ➑ Dimensions are without roof curb.
❹ High electric heater capacity.
* Weight does not include any options.Please contact Untes for options' weights.
❺ Outside air temperature 14 °C DB, coil water in/out is 90 / 70 °C.

7
Rooftop Packaged Air Conditioners

Discover Innovative Rooftop Overall Test


and Validation Laboratory!

Eliminate Know in advance Verify unit limits at


all the risks how the unit will severe operating
at start up operate at actual conditions
operating conditions

8
Rooftop Packaged Air Conditioners

Control System

Standart Control Features Additional Control Options


URTP control panel presents all features of basic air conditioning - CO2 Detector
applications itself. - Smoke Detector
- Room Control Unit - Filter Clogging Alarm
- Auto Heating/Cooling Mode Transition - Humidity Sensor
- Manual Dehumidifying Mode - Maintenance Alarms
- Night or Holiday Time Mode - Indoor Air Flow Rate Control
- System Error Monitoring and Tracking (Constant Air Volume)
- Service Alarms - Head Pressure Control for Low Temperature
- Smart Defrost System Cooling
- Daily and Weekly Schedule Fuction
- Standart Modbus Connection for Building Management System (BMS)
- Ethernet and RS-485 Ports for Local/Remote Servicing

9
Export Sales Office Manufacturing Plant-2
Address: 53. Cadde 1450. Sokak Ulusoy Water Chiller and Heat Pumps
Plaza No: 9/50 Cukurambar, Ankara, Turkey Address: Istanbul Yolu 24.km Saraykoy, Ankara
Email: [email protected]
T+90 (312) 287 91 00 F+90 (312) 284 91 00

Manufacturing Plant-1
Air Handling & Ventilations Systems,
Fan Coil Systems
Packaged Air Conditioning Systems
Address: Istanbul Yolu 37.km
Kahramankazan, Ankara, Turkey

Untes Heating Air Conditioner Inc. reserves the right to make changes in the products, technical data, figures, designs and materials of the products in
the catalog without any notice or information. All contents are copyrighted by Untes.