EKS 3 - Programming: Step 1: Press The Confirm
EKS 3 - Programming: Step 1: Press The Confirm
The system will go through a brief test cycle when the ignition is turned on.
Once the self test is complete, the operator must verify the Parts of line to
be used and the proper Operating code (from Load Chart). In addition, the
Confirm Key must also be pressed.
The below steps can be completed in any order, but all three must be
preformed for the LMI to allow craning functions.
3
Mode Key for one second, i 1 2 3
this will cause the decimal klbs
max
Step 2: Using the numbered key pad (0-9) begin to enter the desired operating
mode (from the appropiate Load chart). You can also scroll through all of the
Cranes Operating Modes by pressing the operating mode button 3 as it will
scroll up to the next highest operating mode.
II I
t no
.2. n=
2
410.0. 00 3 ft
F1 1 2 3 4 5 1 CE
F2 6 7 8 9 0 6
EKS 3 - Changing Parts of Line
Step 1: Press and hold the Confirm/Change button 6 and then touch the
Parts of Line button 2 , the parts of line number in the display window
should begin to blink. Release all buttons.
Step 2: Using the numbered key pad (0-9) begin to enter the desired parts of
line (input a zero for single digit parts of line). You can also scroll through all of
the parts of line by pressing the parts of line button 2 as it will scroll up to the
next highest parts of line.
II I
t no
.2. n=
2
410.0. 00 3 ft
F1 1 2 3 4 5 1 CE
F2 6 7 8 9 0 6
EKS 3 - Error Codes
1 . 138
Error Group
Single Errors
Group Single
Error (Countermeasure)
of Errors Errors
1. 1 Incorrect configuration (check EKS code and rigging mode)
2 Incorrect reeving mode (verify proper parts of line)
3 New code or reeving mode selected (delete decimal point
at code or reeving mode status display)
8 Incorrect EKS code selected (verify correct EKS code)
2. var. Various-Notify Grove Cust. Support
3. var. Various-Notify Grove Cust. Support
4. 1 Transmitter Board - Rod side pressure 1)
2 Transmitter Board - Main Boom Angle 1)
3 Transmitter Board - Tele sect. II - IV 1)
5 Transmitter Board - Piston side pressure 1)
6 Transmitter Board - Tele sect. I 1)
7 Transmitter Board - Angle of Telescopic swing-away,
lattice extension 1)
5. 1 Incorrect Telescope status (check EKS code and reeving)
2 Radius to large (raise main boom)
6. 1 Incorrect Main Boom Angle (raise main boom)
2 Incorrect Lattice extension angle (raise or lower lattice ext.)
3 Telescoping retraction locked (maintain tele. order or boom
angle)
7. var. Various (check and if necessary replace SLI F3 fuse)
8. 1 Data Transmitter; see error groups 4 and 7 (check SLI code
and configuration, otherwise notify Grove Cust. Support)
2 Boom System (check SLI code and configuration, otherwise
notify Grove Cust. Support)
9. var. Various-Notify Grove Cust. Support
C. var. Ambient temperture of EKS is too high or too low. Heat the
operators cab or ventilate until error disappears.
E. var. Various-Notify Grove Cust. Support
1) Errors in error group 4 may be caused by a defect in the data transmitter board or a blown fuse.