Low Profile Self-Leaded Current Sense Transformers
Low Profile Self-Leaded Current Sense Transformers
Low Profile Self-Leaded Current Sense Transformers
Mechanical Footprint
1 5 2 .100
2X
2,54 .030
2X
0,77
.490 ± .015 R
12,45 ± 0,38
.500 .400
12,70 10,16
R
3 6 4
.100
4x
2,54
.040
4x
1,02
.280 MAX .410
7,11 10,41
U.S.A: TEL 619 674 8100 • EUROPE: TEL 44 1483 401700 • ASIA: TEL 886 7 821 3141 • WEB: http://www.pulseeng.com
PC502.E (9/98) 8
THT CURRENT SENSE
TRANSFORMERS
W !
NE UL and C-UL recognized, TÜV approved components
3000 Vrms gate to drive winding test
Useful operating frequency from 50 KHz to 500 KHz
Most popular winding configurations
Additional Specifications
Reference Data Calculation Data
Part Ipk Droop Max Flux Req
Number RT Kb
(Amps) (%) Density (mΩ)
P0581 200 34 1.00 2000 17.12 .9
P0582 100 35 1.98 2000 68.49 .8
P0583 15 36 1.19 2000 273.97 .75
NOTES: 1. These current sense transformers have two one turn primaries that can 4. To calculate the droop: Droop Exponent (D) = Rt * don/(Lpri in mH * Freq. in
be used in parallel. The listed current ratings are for parallel connection. KHz) %Droop = (1-e-D) * 100
2. The reference values are for an application using the termination resistor 5. The temperature rise of the component is calculated based on the total core
(Rt) and operating with unipolar waveform at 100 KHz, 40% duty cycle. loss and copper loss:
The estimated temperature rise is 55° C. A. To calculate total copper loss (W): P(cu) = Ipk2 * Req * Ff * don
3. The peak flux density should remain below 2100 Gauss to ensure that the where: Ff is 1 for unipolar waveform and 2 for bipolar waveform
core does not saturate. Use the following formula to calculate the peak B. To calculate total core loss (W): P(core) = 0.000073 * (Freq. in KHz)1.67 *
flux density: Bpk = Kb * Ipk * Rt * don/(Ff * Freq. in KHz) where: Rt is the (Bop in kG)2.532 where: Bop in kG = Kb * Ipk * Rt * don/(2000 * Freq. in KHz)
terminating resistor in the application and Ff is 1 for unipolar waveform C. To calculate temperature rise: Temperature Rise (C) = 60.18 * (Core
and 2 for bipolar waveform Loss(W) + Copper Loss (W)).833
Mechanical Schematic
.700
17,78 Weight . . . . . . . . . . . . . . . .5 grams
3
10 7 Tray . . . . . . . . . . . . . . . . . . .20/tray
1 4
.350
8,89 (6X) .040
10 7 Dimensions: Inches
1 .200 4 mm
8 Unless otherwise specified, all tolerances are ± .010
5,08 0,25
U.S.A: TEL 619 674 8100 • EUROPE: TEL 44 1483 401700 • ASIA: TEL 886 7 821 3141 • WEB: http://www.pulseeng.com
9 PC502.E (9/98)
THROUGH HOLE CURRENT
SENSE TRANSFORMERS
VDE Approved
Mechanical Schematic
4
4374
1 2
(2 X) .051 ± .003
1,30 0,08
U.S.A: TEL 619 674 8100 • EUROPE: TEL 44 1483 401700 • ASIA: TEL 886 7 821 3141 • WEB: http://www.pulseeng.com
PC502.E (9/98) 10
THOUGH HOLE CURRENT
SENSE TRANSFORMERS
AND INDUCTORS
VDE Approved
Designed for switching power supply
applications
Transformer meets IEC950 insulation
requirements
Frequency range from 20 KHz to 200 KHz
Electrical Specifications @ 25°C — Operating Temperature -30°C to 130°C
Part Number Part Number Part Number Secondary Secondary Primary Primary
Transformer Schem. Transformer Schem. Inductor Schem. Turns Inductance Inductance RS RT Unipolar Bipolar
with 2-1 T Figure with 1T Figure without Figure NS MH Test Voltage (Ω MAX) (Ω NOM) Amp µ Sec. Amp µ Sec.
Primaries Primary Primary (MIN) (15.75 KHz) Rating (MAX) Rating (MAX)
— 1C PE-63586 1A PE-51686 2A 50 5.0 0.5 0.7 50 150 300
PE-64487 1C PE-63587 1A PE-51687 2A 100 20.0 1.0 1.40 100 300 600
PE-64488 1C PE-63588 1A PE-51688 2A 200 80.0 2.0 4.50 200 600 1200
PE-64517 1D PE-63617 1B PE-51717 2B 50CT 5.0 0.5 0.7 50 150 300
PE-64518 1D PE-63618 1B PE-51718 2B 100CT 20.0 1.0 1.40 100 300 600
PE-64519 1D PE-63619 1B PE-51719 2B 200CT 80.0 2.0 4.50 200 600 1200
— — PE-63691 1B — — 300CT 180.0 3.0 11.0 300 900 1800
NOTES:
1. Maximum ratings specified with rated secondary terminating resistance 3. Maximum operating temperature 105°C (ambient plus rise).
and 1 turn primary. 4. When terminated with rated terminating resistance, the inductor scale
2. Amp-microsecond (AµSec.) rating of primary equals volt microsecond factor is Vout = 1 volt per amp. for center tapped units terminating
(VµSec.) rating of secondary when secondary is terminated in rated resistance for each half of winding is listed value divided by two.
resistance. (Amp—microseconds is equal to the product of a square 5. 1 turn primary peak sense current is 20 amps for all parts listed above.
pulse of current in amps, times the current pulse width in microseconds.
Mechanicals Schematics
Transformer Inductor
1A 1B
1 3 1 3
1 6 3 .390
9,91MAX 4
PE-XXXXX 4 .700 MAX
DATE CODE 17,78
2 5 5
2 7 5 .670 2
17,02MAX
.900 MAX
22,86 .170
4,32MIN 1C 1D
.800 3
V 1457
20,32 1 3 1
.720 MAX
DE 17,78 2 2
.010 MIN 4
0,25 1441
6 6
.500 MIN
.015 7 5 7 5
12,70
0,38MIN
.200 .250
.250
6,35 .500/.700 MAX/MIN
5,08 6,35 12,70/17,78
.051 .003 .030 .002
4X 1,30 ±,076 .700 2X 0,76 ±,051 .500
.500
12,70 .030 .002
2A 2B
17,78 12,70
(Leads: 1,2,6,7) (Leads: 3,5) 0,76 ± 0,05 1 1
Solderable
Pin
2
3 3
Dimensions: Inches Unless otherwise specified, all tolerances are ± .005
mm 0,13
U.S.A: TEL 619 674 8100 • EUROPE: TEL 44 1483 401700 • ASIA: TEL 886 7 821 3141 • WEB: http://www.pulseeng.com
11 PC502.E (9/98)
500 KHZ CURRENT SENSE
TRANSFORMERS & INDUCTORS
Through Hole Package
Frequency range from 200 to 500 KHz
Mechanicals
Inductor Transformer
.380
MAX
9,65
.580
MAX
14,73
PE-5287X .580
MAX
DATE 14,73
.120/.155
PE-6497X
3,05/3,94 1 4 DATE
.325 .400 .120/.155
MAX
8,26 10,16 3,05/3,94 1 2 3 4 .150
.325 3,81
.550 MAX .100
MAX 8,26 .150
13,97 2,54 .400 3,81
Dimensions: Inches 10,16
mm .550
MAX
Unless otherwise specified, 13,97
all tolerances are ± .010
0,25 Schematics
Inductor Transformer
1 1
USER 3
PROVIDES NS TURNS 1 TURN NS TURNS
TURN 4
4 2
U.S.A: TEL 619 674 8100 • EUROPE: TEL 44 1483 401700 • ASIA: TEL 886 7 821 3141 • WEB: http://www.pulseeng.com
PC502.E (9/98) 12