0% found this document useful (0 votes)
827 views8 pages

Base Plate Circular

The document provides design details for the base plate of a pipe stanchion. It includes inputs like the pipe diameter, stanchion height, wind and friction forces, dimensions for the base plate and anchor bolts. It then calculates the tension forces on the anchor bolts from the different load cases and checks that the anchor bolts and concrete can withstand these forces. It also checks the required thickness of the base plate.

Uploaded by

mrprabhu16
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
827 views8 pages

Base Plate Circular

The document provides design details for the base plate of a pipe stanchion. It includes inputs like the pipe diameter, stanchion height, wind and friction forces, dimensions for the base plate and anchor bolts. It then calculates the tension forces on the anchor bolts from the different load cases and checks that the anchor bolts and concrete can withstand these forces. It also checks the required thickness of the base plate.

Uploaded by

mrprabhu16
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 8

DESIGN OF BASE PLATE FOR PIPE Inputs

15MS603A
Column Pipe Section P406.40mm (pipe dia)
Height of Stanchion h = 4.85m
Ph1 = 6.40 Kn (Friction force)
Ph2 = 10.00 Kn (Wind force against Friction and structure)
N = 62 Kn
Dimension of Base Plate D = 0.640 m b = 0.640 m
Dia. Of anchor Bolt = 0.030 m No of Anchor bolt in either dir. = 3
Anchor Bolt capacity Tension = 53 Kn Shear = 18 Kn
Grade of Concrete = 25 N/mm2
Steel yield Strength = 235 N/mm2
dt = 0.060 m
dt /3 = 0.020 m
d = 0.580 m
M = 31.04 KN-m
e = 0.499 m

Tension Force Effects :-

D/6 = 0.107 m
(D/6 + dt/3) = 0.127 m

3- Tension force affects (Anchor Bolts) бc = 2N(e+D/2-dt) / (b.Xn(d-dt-Xn/3)), Z = N(e-D/2+Xn/3)

x/d = (e-D/2) / d
x/d = 0.308
r = at / (b.d)
r = 0.006
Xn/d = 0.52 (From Graph)
Xn = 0.30 m

So σc1 = 0.94 N/mm2


Z1 = 33.46 Kn (Per 3 Anchor Bolts)

For Ph2 = 10.00 Kn


M = 48.50 KN-m
e = 0.779 m
3- Tension force affects (Anchor Bolts) бc = 2N(e+D/2-dt) / (b.Xn(d-dt-Xn/3)), Z = N(e-D/2+Xn/3)

x/d = 0.792
Xn/d = 0.46 (From Graph)
Xn = 0.27 m

σc2 = 1.46 N/mm2


Z2 = 65.68 Kn (Per 3 Anchor Bolts)

CHECKS

1- Compression Check of Concrete


(σc1 + σc2) / fc' = 0.096 OK

2- Anchor Bolt Check

i) Tension
(Z1+Z2) /no. of bolt = 33.05 Kn
(Z1+Z2) /no. of bolt /(Anchor Bolt Tension Capacity) = 0.62 OK

ii) Shear
((Ph12 +Ph22) ^0.5 /8) /Anchor Bolt Shear Capacity

0.229 OK
Combination of Anchor Bolt Shear force shall be checked
0.852 OK

3- Check Of Base Plate Thickness

i) Compression

l = 164 mm
b = 289 mm
therefore l/b = 0.570

Mx = 0.0404 σc b2
My = -0.2804 σc l2
Mx = 3173.46 N-mm/mm
My = -11065.83 N-mm/mm

t = (6*Mmax / fb)^0.5
t = 19 mm

ii) Tension

Z = bt2 / 6
b = 160 mm
Z = 27 t^2

σ = Me / Z < fb
M = (Z1+Z2) /3
fb = 0.66 fy 1.25

t = 38 mm WITHOUT TEFLON SHEET


260 mm 260 mm

640 mm

e-D/2+Xn/3)

640 mm

e-D/2+Xn/3)
P406.40mm

M30 Bolt