Disclosure To Promote The Right To Information
Disclosure To Promote The Right To Information
Disclosure To Promote The Right To Information
UDC 621.643.4.062.3:[678.742.2-JX596.115
@ Copyright 1977
Gr 2 May 1977
IS : 8360 ( Part II ) - 1977
Chairman Rcprexenting
SHRI V. D. DESAI Bombay Municipal-Corporation
Members
ADVISER Ministry of Health
SHRI B. B. Rau ( Allen& )
SIIEI H. R. BADYAL Indian Iron 8t Steel Co Ltd, Calcutta
SHRIX. D. BISWAS ( Alternate )
SHRI S. P. CHAKRABARTI Ceot~lor~~ildi”g Research Institute ( CSIR ),
0
SHRI S.K.SIiAItMA (Allcmafc)
CHIEF ENGINEER Central Public Works Department, New Delhi
SUPERINTENDINO ENOINF,ER( Allcrnalc )
CHIEF ENQINEER Tamil Nadu Water Supply & Drainage Board
Madras
CHIEF ENGINEER U. P. Jal Nigam, Lucknow
SU~ERINTENDINCI ENQINEER( Alkrnata )
CHIEF ENGINEER( WATER ) Municipal Corporation of Delhi
DRAINAGE ENCXNEER( Alternate )
CITY ENGINEER Bombay Municipal Corporation
HYDRAULIC ENGINEER( Allcmafe )
SHRI H. N. DALLAS Indian Institute of Architects, Bombay
LALA G. C. DAS National Test House, Calcutta
SHRI T. R. DE Institution of Engineers ( India ), Calcutta
SHRI M. T. KANSE Directorate General of Supplies & Diiposals
SHRI S. C. KAPOOR Delhi Devrlopment Authority
SKRI R. V. LELE Central Glass & Ceramic Research Institute
( CSIR ), Calcutta
PROF N. MAJUMDER National Environmental Engineering Research
Institute ( CSIR ), Nagpur
SHRI J. M. DAVF: ( Allematc )
SHRI R. N. MALLICK Directorate General of Technical Development
SHRI N. R. SRINI~ASAN ( Al&nate )
( Conhuud on page 2 )
@ Cofivri/ht 1977
BUREAU OF INDIAN STANDARDS
This publication is protected under the Indian Copyrighf Ad ( XIV of 1957 ) and
reproduction in whole or in part by any means except with written permission of
the publisher shall be deemed to be an infringement of copyright under the said Act.
IS I 8360 (Part II) - 1977
( Continuedfrom page 1 )
Members Representing
SRRI R. M. MEHRA Bombay Potteries & Tiles Ltd, Bombay
SHRI R. N. MUKEERJEE Calcutta Metropolitan Planning Organization
SRRI 8. K. NEOGI ( Altcmatc )
SHRI D. APPUKUTTAN NAYAR Public Health Engineering Department, Government
of Kerala, Trivandrum
SHRI K. RA~MACHANDRAN(Al&mare )
COL RAJ KUMAR Engineer-in-Chief’s Branch, Army Headquarters
SHRI I. S. BEDI ( Altarnatr )
SHRI P. S. RAJVAN~AI Public Health Engineering Department, Government
of Rajasthan, Jaipur
SHRI RANJIT SINGE Ministry of Railways
DR A. V. R. RAO National Buildings Organization, New Delhi
SHRI G. T. BHIDE ( AIternatc )
SHRI P. JAQANATH RAO E. I. D. Parry Ltd, Madras
SRRI T. S. CHINTAMANI ( Alternate )
SHRI J. L. SETH1 Public Health Engineering Department, Government
of Haryana, Chandigarh
SHRI A. N. hkiANm4LE ( ~&raarr )
SHRI R. K. SOMANY Hindustan Sanitaryware & Industries Ltd,
Bahadurgarh
SERI V. S. BHATT ( A&mat6 )
SEXI D. AJITEA SIMHA, DirectorGeneral,IS1 ( Ex-oficio Member )
Director ( Civ Engg )
SRRI S. P. M~aau
Assistant Director ( Civ Engg ), IS1
Members
SHRI S. H. MHATRE( AIternate to
Shri K. D. Mulekar )
ADVISEB Ministry of Health
SSIRI V. A. ANANDADO~S ( Alternate )
DE B. R. C. ANAND Calico Chemicals, Plastics and Fibres Division,
Bombay
SERI S. MITRA ( Aftemak )
SBRI P. M. APTE Houss~ &&ban Development Corporation Ltd,
( Continued on page 6 )
2
IS t 8360 ( Part II ) - 1977
Indian Standard
SPECIFICATION FOR FABRICATED HIGH
DENSITY POLYETHYLENE ( HDPE ) FITTINGS
FOR POTABLE WATER SUPPLIES
-PART II SPECIFIC REQUIREMENTS FOR 90” TEES
0. FOREWORD
0.1 This Indian Standard ( Part II ) was adopted by the Indian
Standards Institution on 17 January 1977, after the draft finalized by
the Sanitary Appliances and Water Fittings Sectional Committee had
been approved by the Civil Engineering Division Council.
0.2 The fabricated HDPE fittings are used for connection, by welding
process, to HDPE pipes covered by IS : 4984-1972*.
0.3 The requirements of fabricated HDPE fittings are covered in three
parts of this standard. Part I of the series deals with the general require-
ments applicable to all fabricated HDPE fittings and specific requirements
of different types of fittings are covered in separate parts of the standard.
This Part II deals with the specific requirements for 90” tees.
0.4 For the purpose of deciding whether a particular requirement of
this standard is complied with, the final values, observed or calculated,
expressing the result of a test or analysis, shall be rounded off in accor-
dance with IS : 2-1960t. The number of significant places retained in
the rounded off values should be the same as that of the specified values
in this standard.
1. SCOPE
1.1 This standard ( Part II ) lays down the requirements for manu-
facture, dimensions and tolerances and marking for fabricated HDPE
90” tees for potable water supplies.
*Specification for high density polyethylene pipes for potable water supplies
( first revision ) .
tRules for rounding off numerical values ( revised ).
3
IS t 8360 ( Part II ) - 1977
2. REQUIREMENTS
2.1 General - The general requirements for material, sizes, method of
test and sampling shall conform to IS : 8360 ( Part I )-1977*.
2.2 Manufacture
2.2.2 Laying Length - The overall laying length 5 and the tolerance
thereon shall comply with those given in Table 1 read with Fig. 1.
2.2.3 The outside diameters and wall thicknesses of pipes out of which
YiWees are fabricated shall comply with those given in IS : 8360 ( Part I )-
*_ The wall thickness of a fabricated 90” tee shall not be less than
that of the pipe to which it is to be welded.
3. MARKING
3.1 Each fabricated 90” tee fitting shall be marked with the following
information:
a) Manufacturer’s name or identification mark, and
b) The size of the fitting and the appropriate class ( working
pressure ) to which the pressure rating ofthe fitting corresponds.
*Specification for fabricated high density polyethylene ( HDPL ) fittings for potable
water supplies: Part I Gsneral requirements.
4
TABLE 1 DIMENSIONS FOR LAYING LENGTH OF FABRIGATED 90” TEES
( C&uI82.2.2 aml Fig. 1 )
SIZE TBEU,OPEBALL
900
h%!Il’IOblVOTH, z
(1) (2)
mm mm
20 so& 2
25 62.5 f 2
32 80* 2
40 m* 2
!iO *f 2
63 94-s * 4
75 112-S& 4
90 135f 4
110 16!J* 4
125 181.5 f 4
140 210& 6
160 240f 6
180 270& 6
200 300& 6
225 537.5 f I3
250 3755 8
280 420 f 8
315 472-5 f .8
355 532.5 f 10
400 600 f 10
450 675 f 10
500 75OflO
-~ ~-
3.1.1 Each fabricated 90” tee fitting may also be marked with the
Standard mark.
3.1.2 The use of the Standard Mark is govered by the provisions of the
Bureau of Indian Standards Act, 1986 and the Rules and Regulations made
thereunder. The details of conditions under which the licence for the use of
Standard Mark may be granted to manufacturers or producers may be obtained
from the Bureau of Indian Standards.
5
IS t 8360 ( Part II ) - 1977
( Conlinuedfrompage2 )
Members RepraSnfing
SHBI S. S. CEXHEDA Small Scale Plastics Pipes and Fittings Manufacturers*
Association, Bombay
CHIET ENoINEEE TamMafr;u Water Supply & Drainage Board,