HS - 300-250-381 - B - 1-F2-DS-BBQE, Primary Pump

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Company name:

Created by:
Phone:

Date: 12/16/2017
Position Count Description
1 HS 300-250-381 B 1-F2-DS-BBQE

Product photo could vary from the actual product


Product No.: 99281950

Non-self-priming, single-stage centrifugal pump with radial suction and radial discharge port.

Pump for the pumping of thin, clean or slightly contaminated, non-aggressive liquids without abrasive
or long-fibred solids.

The pump has horizontal pump shaft and the housing can be dismantled in the horizontal plane along
the drive shaft.

Pump and motor are mounted as separate units on a common baseframe and connected via a
flexible coupling.

The impeller is hydraulically as well as dynamically balanced.

Complete unit consists of pump, baseframe, coupling guard and electric motor.

Liquid:
Pumped liquid: Cold water / cooling water
Liquid temperature range: 32 .. 212 °F
Liquid temperature during operation: 68 °F
Density: 62.4 lb/ft³
Kinematic viscosity: 1 cSt

Technical:
Actual calculated flow: 3240 US gpm
Resulting head of the pump: 64.66 ft
Actual impeller diameter: 15.35 in
15.35 in
Impeller nom: 15 in
Impeller max: 15.35 in
Primary shaft seal: BBQE
Rotation direc: CW
Rated head: 64.66 ft
Rated flow: 3240 US gpm

Materials:
Pump housing: Cast iron
ASTM A48-35A
Impeller: Stainless steel
EN 1.4301
ASTM 304

Installation:
Maximum ambient temperature: 140 °F
Maximum operating pressure: 232 psi
Flange standard: DIN
Pump inlet: DN 300
Pump outlet: DN 250

Printed from Grundfos Product Center [2017.08.028] 1/7


Company name:
Created by:
Phone:

Date: 12/16/2017
Position Count Description
Pressure stage: 16
Coupling type: Pin and bush coupling

Electrical data:
Motor type: MMG250MC
IE Efficiency class: IE2
Rated power - P2: 60.35 HP
Main frequency: 50 Hz
Rated voltage: 3 x 380-420D/660-725Y V
Rated current: 82,5-77,0/47,5-44,5 A
Starting current: 580-580 %
Cos phi - power factor: 0,9
Rated speed: 985 rpm
IE efficiency: IE2 94,5%
Motor efficiency at full load: 94.5-94.5 %
Number of poles: 6
Enclosure class (IEC 34-5): 55 (Protect. water jets/dust)
Insulation class (IEC 85): F

Others:
Net weight: 3590 lb
Shipping volume: 111 ft³
Rotation direc: CW

Printed from Grundfos Product Center [2017.08.028] 2/7


Company name:
Created by:
Phone:

Date: 12/16/2017

99281950 HS 300-250-381 B 50 Hz
H HS 300-250-381 B, 3*415 V, 50Hz eta
[ft] [%]
Q = 3240 US gpm
H = 64.66 ft
n = 100 % (50Hz)
Pumped liquid = Cold water / cooling water
Liquid temperature during operation = 68 °F
Density = 62.4 lb/ft³
100 %
80

70

60

50 100

40 80

30 60

20 40

10 20

Eff pump = 88.8 %


0 0
0 500 1,000 1,500 2,000 2,500 3,000 3,500 Q [US gpm]
P2 NPSH
[HP] [ft]

70 35

60 30

50 25

40 20

30 15

20 10

10 5
P2 = 59.67 HP
NPSH = 9.6 ft
0 0

Printed from Grundfos Product Center [2017.08.028] 3/7


Company name:
Created by:
Phone:

Date: 12/16/2017
H HS 300-250-381 B, 3*415 V, 50Hz eta
Description Value [ft] [%]
Q = 3240 US gpm
General information: H = 64.66 ft
Product name: HS 300-250-381 B n = 100 % (50Hz)
100 % Pumped liquid = Cold water / cooling water
1-F2-DS-BBQE 80
Liquid temperature during operation = 68 °F
Product No.: 99281950 Density = 62.4 lb/ft³
EAN: 5713826517670 70

Technical: 60

Actual calculated flow: 3240 US gpm


50 100
Resulting head of the pump: 64.66 ft
Actual impeller diameter: 15.35 in
40 80
15.35 in
Impeller nom: 15 in
30 60
Impeller max: 15.35 in
Primary shaft seal: BBQE 20 40
Pump version: 1
Rotation direc: CW 10 20
Rated head: 64.66 ft
Eff pump = 88.8 %
Rated flow: 3240 US gpm 0 0
0 1,000 2,000 3,000 Q [US gpm]
P2 NPSH
Materials: [HP] [ft]
Pump housing: Cast iron
60 30
ASTM A48-35A
Impeller: Stainless steel 50 25
EN 1.4301 40 20
ASTM 304
30 15
Material code: DS
20 10

Installation: 10 P2 = 59.67 HP 5
NPSH = 9.6 ft
Maximum ambient temperature: 140 °F 0 0
24.80"17.87"
17.87

40.67"

66.54"

x
0.24"
0.91" 19.17"
21.85
3.23"
25.39"
7.87"

Maximum operating pressure: 232 psi


2 3/4
2.25"
23.62
41.38
17.01"
22.99"
36.26"
0.12

Flange standard: DIN


Connect code: F2 41.38 36.26"
23.62 0.12 22.99" 17.01"
Pump inlet: DN 300 2.25" 2 3/4

Pump outlet: DN 250


24.80"

Pressure stage: 16
40.67"

Coupling type: Pin and bush coupling


17.87"

17.87

Liquid: 3.23" 0.24"


x 0.91" 19.17"
0.43"

Pumped liquid: Cold water / cooling water 7.87" 25.39" 7.87" 21.85

66.54"
Liquid temperature range: 32 .. 212 °F
Liquid temperature during operation: 68 °F
Density: 62.4 lb/ft³
Kinematic viscosity: 1 cSt

Electrical data:
Motor type: MMG250MC
IE Efficiency class: IE2
Rated power - P2: 60.35 HP
+T +T +T

Main frequency: 50 Hz
Rated voltage: 3 x 380-420D/660-725Y V
CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY

Rated current: 82,5-77,0/47,5-44,5 A


IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE

TO AMPLIFIER

Starting current: 580-580 % RELAY


L1 L2 L3

Cos phi - power factor: 0,9


THERMISTORS PTC ACCORDING TO DIN 44082

Rated speed: 985 rpm


IE efficiency: IE2 94,5% +T +T +T

Motor efficiency at full load: 94.5-94.5 %


Number of poles: 6
Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) TO AMPLIFIER
RELAY

Insulation class (IEC 85): F L1 L2 L3

Printed from Grundfos Product Center [2017.08.028] 4/7


Company name:
Created by:
Phone:

Date: 12/16/2017
Description Value
Motor protection: PTC
Motor Number: 96292830

Others:
Net weight: 3590 lb
Shipping volume: 111 ft³
Product range: ASIA
Rotation direc: CW

Printed from Grundfos Product Center [2017.08.028] 5/7


Company name:
Created by:
Phone:

Date: 12/16/2017

99281950 HS 300-250-381 B 50 Hz

17.87
0.43"
17.01"

19.17"
21.85
22.99"

24.80" 17.87"
7.87"

40.67"
x 0.91"
36.26"

0.24"
2 3/4
0.12

66.54"
2.25"
23.62

25.39"
41.38

3.23"
7.87"

Note! All units are in [mm] unless otherwise stated.


Disclaimer: This simplified dimensional drawing does not show all details.

Printed from Grundfos Product Center [2017.08.028] 6/7


Company name:
Created by:
Phone:

Date: 12/16/2017

99281950 HS 300-250-381 B 50 Hz

+T +T +T

CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY


IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE
TO AMPLIFIER
RELAY
L1 L2 L3

THERMISTORS PTC ACCORDING TO DIN 44082

+T +T +T

TO AMPLIFIER
RELAY
L1 L2 L3

All units are [mm] unless otherwise presented.

Printed from Grundfos Product Center [2017.08.028] 7/7