Startup-Basic: User Manual
Startup-Basic: User Manual
Startup-Basic: User Manual
STARTUP-BASIC
INSTALLATION AND CONFIGURATION
E-SW-BASIC & E-SW-BASIC/PQ
STARTUP-BASIC SOFTWARE START UP GUIDE
INDEX
1 GENERAL 3
2 SAFETY PRESCRIPTIONS 4
4 GETTING STARTED 8
5 SOFTWARE INSTALLATION 10
6 SOFTWARE START-UP 10
1 GENERAL
1.1 About this guide
This guide describes the required operations to install and configure Atos E-SW-BASIC(/PQ) programming
software for Atos digital electrohydraulics.
Before installing or operating the driver for the first time, read this guide.
The purpose of this guide is not to cover all the details or variations of Atos drivers and software, and it does not
provide complete details for all possible working conditions; if any further information or technical support are
required, please contact the Technical Sales Support of Atos Electronic Division ([email protected]).
The guide contains important safety instructions (see 2), whose knowledge is required to:
avoid hazards and dangers
minimize repair costs and downtime
increase the working and reliability of the driver
In addition please follow up all the current regulations of the country/community where the drivers will be used.
A basic skill in using personal computers and Windows® operating system is required.
1.2 Trademarks
All Atos trademarks ™ and ® are distinctive sign of Atos rights, know-how, and in general intellectual
properties. Partial or full-unauthorized reproduction of this guide, images, logos, or casting through internet,
may be object of punishment by local law.
Upon delivery, all installed software is copyright-protected. The software may only be reproduced with our
written consent or in accordance with the license agreement.
Windows® is a registered trademark of Microsoft Corporation
Pentium® is a registered trademark of Intel Corporation
An automatic e-mail service will inform all users of registered software whenever new software updates
are available.
Additional information about valves, electronic drivers and software can be found into the E-SW DVD or
in the Atos Catalog on-line.
2 SAFETY PRESCRIPTIONS
The software and the connected electronics must not be operated until it has been determined that the system
in which they are installed, meets all applicable standards and safety regulations for the application.
all information and instructions reported in this guide and in the supplementary documentation (see 3.2),
must always be observed to avoid damage and injury
Driver faults may compromise safety or change operating conditions, shut down the driver immediately
and notify qualified personnel.
all of the relevant local and plant/machine specific regulations must be always observed
Hazardous situations may occur whenever the driver:
is not properly transported and stored
is altered or modified
is not installed, commissioned and operated by qualified persons
is not used properly
Adherence to limits defined by regulations and standards are the responsibility of the manufacturer of the
system or machine.
The graphic interface is organized in pages and levels (see 3.4) related to
different specific functional groups and it allows to:
simply access all the functional parameters of Atos digital proportional
valves and drivers
numerically adapt the factory preset parameters to the application
requirements
verify the actual working conditions
identify and quickly solve fault conditions
store the customized setting into the valve and into the PC
Main features
automatic valve recognition
multilevel graphic interface
numeric parameters settings (scale, bias, ramp, linearization, dither, etc.)
real-time parameters modification
diagnostic and monitor signals
preset data storing into the digital driver
internal database of customized preset
PS serial RS232 – USB communication adapter and cross cables (see 4.1.3)
Main Menu
Press desired button to browse the available contents.
Registration
Press Registration button to apply a registration request for Atos Download Area and for E-SW programming
software:
Installation Wizard
Press Software Installation button to start the installation E-SW programming software (see 5).
Documentations
Press Documentations button to access:
Manuals: specific driver operating manuals in PDF format for Atos full range of digital proportional electronics
Inside the DVD case is placed ‘Access Password’ label to change graphic interface levels (see 3.4).
‘Access Passwords’ are also available in Atos Download area (see 1.3).
E-SW-*-N programming software are not supplied with ‘Access Passwords’ (for further information see
technical table GS500).
‘Username’ and ‘Password’ to access in the personal Atos Download Area (see 1.3)
‘File (*.txt)’ in attachment containing ‘User Name’ and ‘Activation Code’ for software activation (see 6.1)
A further access password will be available only upon attending a dedicated training in Atos and upon
submitting a detailed description of the application requirements to [email protected]:
Level 3 - Expert: free access to all the valve/driver parameters to specially customize the valve
behaviour
Access Password
The control allows the user to input the password for the desired level of
the graphic interface; access passwords are available in Atos Download
Area (see 1.3) or inside the DVD case (see 3.2).
user with low experience in driver settings can handle basic parameters
A further access password is available only upon attending a dedicated training in Atos and upon submitting
a detailed description of the application requirements to [email protected] .
free access to all the driver parameters to specially customize the valve behaviour
4 GETTING STARTED
This section contains a brief review of the main operations required to install and configure E-SW software,
cables and USB adapters.
If internet connection is not available, press Registration Form (.pdf) button (see 3.2).
Software installation
start software and USB drivers installation adapters using E-SW DVD (see 3.2)
insert the activation code received upon registration (see 6.1)
verify the correct software installation and configuration (see 5 and 6)
To install Atos software, the user must have administrator rights on the system.
Install E-SW programming software before plug-in the adapter in the PC USB port.
To fully operate the E-SW software and the digital electrohydraulic, please refer to the relevant
documentation (see 3.2).
WARNING: drivers USB port is not isolated! Use of USB isolator adapter is highly recommended for
PC protection: wrong earthing connections may cause high potential difference between GNDs,
generating high currents that could damage the PC connected to drivers.
5 SOFTWARE INSTALLATION
This section describes the main operations required to install and configure Atos programming software.
Close any open applications and do not plug any USB adapter to the PC before proceed with the
installation.
When E-SW software already installed in the PC, user data are mantained and software version is
updated (E-SW version lower than 5.9 is not overwrite and the version is maintained in the PC).
When installing different E-SW software, user data are mantained and all software versions are
updated (e.g. Installing E-SW-BASIC/PQ will update also E-SW-BASIC if installed).
6 SOFTWARE START-UP
This section allows describes software first start-up: use this section to verify the correct installation and
configuration of E-SW software.
Refer to specific driver operating manual for detailed description of software functions (see 3.2).
Once installed the software must be activated to be fully operated: apply a registration request for Atos
Download Area and for E-SW programming software to obtain the required activation code (see 3.3).
Software starts at access Level 1 – Basic (to change access level see 3.4) and it works without activation
code for 10 days from the installation date. After 10 days the software stops until the user inputs the activation
code.
Pressing Remind me later button the software works only for 10 days, then it stops working until the
user inputs the user name and activation code (see 3.3).
This procedure is available only for valve connected through E-C-SB-USB/M12 or E-C-SB-USB/BM cable
(see 4.1.1). Use of E-A-SB-USB/OPT isolator adapter is highly recommended for PC protection.
Interface
Use the control to selects the Serial-USB communication as
the active interface to the connected driver in NP, PS, IR
execution (see 4.1).
Speed
The control allows the user to select the speed of the serial
communication with the connected driver: high speeds allow a
faster update of displayed data but may cause Timeout
communication errors.
select E-SW speed
PC port
The control allows the user to select, which USB port has to be used to communicate with the connected
driver among the available USB ports.
select PC port to communicate with the connected valve
Retry Connection
press button to try to connect with the valve using current communication settings
Once verified that all wirings are correct and pressing the driver connection is still not available, please
contact Atos technical support (see 6.3.1).
When installing new E-SW software version check the communication configuration settings.