Calculation Sheet For Centrifugal Pumps: Excel Program File: Pumpmast - Xls Version: 1.02 / Reh
Calculation Sheet For Centrifugal Pumps: Excel Program File: Pumpmast - Xls Version: 1.02 / Reh
SKETCH
NOTES:
Assume is that all grade elevations are at 0.
A) SUCTION:
Equipment name V-3861
Elevation bottom (tangent) line (BTL or BL)
(i.e. skirt height + concrete) > m
Distance minimum level from BTL > m
Distance maximum level from BTL > m
Pump centre line (incl. concrete) = 0.70 m
Height of liquid above pump CL (min) #VALUE! m
Height of liquid above pump CL (max) #VALUE! m
B) DISCHARGE:
Equipment name B.L.
Elevation bottom (tangent) line (BTL or BL)
(i.e. skirt height + concrete) > m
Distance maximum level/inlet nozzle from BTL > m
Pump centre line (incl. concrete) = 0.70 m
Height of liquid above pump CL (max) -0.7 m
D) NPSH REQUIRED:
Equipment name 0
Pump speed (rpm) 2900 1450
Min req'd for single suction pump = 0.92 0.36 m (acc.to hydraulic institute, @ max. specific suction speed, based on water)
Min req'd for double suction pump = 0.58 m (acc.to hydraulic institute, @ max. specific suction speed, based on water)
Min req'd for single suction pump > m (acc. to mechanical department - rotating equipment)
Min req'd for double suction pump > m (acc. to mechanical department - rotating equipment)
Min req'd for single suction pump > m (acc. to manufacturer)
Min req'd for double suction pump > m (acc. to manufacturer)
SKETCH
NOTES:
Assume is that all grade elevations are at 0.
A) SUCTION:
Equipment name V-3861
Elevation bottom (tangent) line (BTL or BL)
(i.e. skirt height + concrete) > m
Distance minimum level from BTL > m
Distance maximum level from BTL > m
Pump centre line (incl. concrete) = 0.70 m
Height of liquid above pump CL (min) #VALUE! m
Height of liquid above pump CL (max) #VALUE! m
B) DISCHARGE:
Equipment name B.L.
Elevation bottom (tangent) line (BTL or BL)
(i.e. skirt height + concrete) > m
Distance maximum level/inlet nozzle from BTL > m
Pump centre line (incl. concrete) = 0.70 m
Height of liquid above pump CL (max) -0.7 m
D) NPSH REQUIRED:
Equipment name 0
Pump speed (rpm) 2900 1450
Min req'd for single suction pump = 0.84 0.33 m (acc.to hydraulic institute, @ max. specific suction speed, based on water)
Min req'd for double suction pump = 0.53 m (acc.to hydraulic institute, @ max. specific suction speed, based on water)
Min req'd for single suction pump > m (acc. to mechanical department - rotating equipment)
Min req'd for double suction pump > m (acc. to mechanical department - rotating equipment)
Min req'd for single suction pump > m (acc. to manufacturer)
Min req'd for double suction pump > m (acc. to manufacturer)
SKETCH
NOTES:
Assume is that all grade elevations are at 0.
A) SUCTION:
Equipment name
Elevation bottom (tangent) line (BTL or BL)
(i.e. skirt height + concrete) > 2.00 m
Distance minimum level from BTL > 0.20 m
Distance maximum level from BTL > 1.30 m
Pump centre line (incl. concrete) = 0.70 m
Height of liquid above pump CL (min) 1.5 m
Height of liquid above pump CL (max) 2.6 m
B) DISCHARGE:
Equipment name B.L.
Elevation bottom (tangent) line (BTL or BL)
(i.e. skirt height + concrete) > 5.00 m
Distance maximum level/inlet nozzle from BTL > 0.00 m
Pump centre line (incl. concrete) = 0.70 m
Height of liquid above pump CL (max) 4.3 m
D) NPSH REQUIRED:
Equipment name 0
Pump speed (rpm) 2900 1450
Min req'd for single suction pump = 0.47 0.18 m (acc.to hydraulic institute, @ max. specific suction speed, based on water)
Min req'd for double suction pump = 0.29 m (acc.to hydraulic institute, @ max. specific suction speed, based on water)
Min req'd for single suction pump > m (acc. to mechanical department - rotating equipment)
Min req'd for double suction pump > m (acc. to mechanical department - rotating equipment)
Min req'd for single suction pump > m (acc. to manufacturer)
Min req'd for double suction pump > m (acc. to manufacturer)
SKETCH
NOTES:
Assume is that all grade elevations are at 0.
A) SUCTION:
Equipment name V-3865
Elevation bottom (tangent) line (BTL or BL)
(i.e. skirt height + concrete) > m
Distance minimum level from BTL > m
Distance maximum level from BTL > m
Pump centre line (incl. concrete) = 0.70 m
Height of liquid above pump CL (min) #VALUE! m
Height of liquid above pump CL (max) #VALUE! m
B) DISCHARGE:
Equipment name E-3863
Elevation bottom (tangent) line (BTL or BL)
(i.e. skirt height + concrete) > m
Distance maximum level/inlet nozzle from BTL > 0.70 m
Pump centre line (incl. concrete) = 0.70 m
Height of liquid above pump CL (max) 0.0 m
D) NPSH REQUIRED:
Equipment name 0
Pump speed (rpm) 2900 1450
Min req'd for single suction pump = 0.47 0.18 m (acc.to hydraulic institute, @ max. specific suction speed, based on water)
Min req'd for double suction pump = 0.29 m (acc.to hydraulic institute, @ max. specific suction speed, based on water)
Min req'd for single suction pump > m (acc. to mechanical department - rotating equipment)
Min req'd for double suction pump > m (acc. to mechanical department - rotating equipment)
Min req'd for single suction pump > m (acc. to manufacturer)
Min req'd for double suction pump > m (acc. to manufacturer)
6.2 barg
103.5
89.9 1.751724 0.052063
13.6 0.119016
0.192
0.363078
KG/HR HR
1200 T/D 50000 4
200T/D 200000