SIMOTICS Reluctance Motor and SINAMICS Converter Siemens Gertjan Bakker
SIMOTICS Reluctance Motor and SINAMICS Converter Siemens Gertjan Bakker
SIMOTICS Reluctance Motor and SINAMICS Converter Siemens Gertjan Bakker
5282_Highlight_Profienergy_K2_EN_360p_450KBit.mp4
PROFIenergy
Restricted © Siemens AG 2017
Higher costs through higher efficiency lower energy costs?
New in EN 50598
Publication
Analysis of the energy usage • The standard was published on Dec. 19th
2014
• Manufacturers of electrically-driven
machines can analyze the energy usage
using standardized load profiles Obligation
• After publication, EN 50598 will be listed in
the EU Official Journal
• As a consequence, converter manufacturers
have a legal obligation (presumption of
conformity with the standard)
Min. efficiency
Line motors operated with converters IE2 acc. to EU Directive
(capable of converter operation) …, 0.75 .. 375, … kW
Published
2014-03-01
EPA: Extended
Product-
Approach:
Electrically driven
machine
Source: EN 50598-2
Restricted © Siemens AG 2017
EN 50598-2 is binding for the SINAMICS V20, G110, G120, G130, G150 and
G180 series
Area of validity of the EN 50598-2 standard
EN 50598-2 can be optionally applied to: In the first step, Siemens applies the EN
50598-2 for the following PDS:
• SIMOTICS FD
⋅ AC–AC converters/CDM capable of energy recovery
& SINAMICS G120P
⋅ AC–DC converters/CDM
• SIMOTICS GP/SD VSD10 Line
⋅ DC–AC converters/CDM & SINAMICS G120
⋅ Devices with other power and voltage classes • SIMOTICS GP/SD VSD4000 Line &
⋅ Any combinations of PDS (CDM and motor) SINAMICS G120
25
RM relative
speed / % 50
+ =
50 100
CDM losses 25
LINK TO STANDARDS
Comparable Reluctance
Energy efficiency Maximum PM synchronous IE3 IE4 PM synchronous
As an example
Performance High servo pump Synchronous
Induction
motor Reluctance Servo
Between 1LE1
List price Low IE3 and IE4 IE3 IE4
Reluctance
Performance / efficiency
Permanent-magnet
synchronous motors
+ Efficient
with
Synchronous reluctance + High dynamic performance
converters
motors + Low costs
with converters For standard drive systems
+ Efficient
+ Highest dynamic performance
- Cost-intensive
For special
IE4 induction motors applications
with converters
+ Rugged
+ Favorably priced
For standard drive systems
+ Rugged converter
+ Simple closed-loop control
DC drives
- Cost-intensive and maintenance-intensive
For special applications
Costs
Restricted © Siemens AG 2017
Page 16 2017-11-10 PD LD P/DF MC GMC
Energy-saving
Higher energy efficiency requires new technologies
New technologies
Efficiency
"IE4"
IE4
SYN
IE3
IE2
Technology
Jaroslaw K. Kostko
1927 – patent for a synchronous motor operating according to the reluctance
principle
Alfredo Vagati
1990 – Professor for electrical machinery and drives at the University of
Cagliari, Italy.
1995 to 2003 Head of the Electrical Engineering Department in the Technical
Institute, Turin, Italy
His scientific research covered power electronics and electric drives. His most
important activity is the design and closed-loop control of high-performance
synchronous reluctance motors (patent back in 1998).
• Comparable with two magnets that are "stuck" • Comparable with two magnets that are quickly
to one another moving together
1LE1 platform IE1 class IE2 class IE3 class IE4 class
DOL
+
Converter-capable
Converter-optimized
motor without efficiency
class according to IEC
Motor voltage optimized 60034-30-1
for converter operation
Only for converter
operation
G120 S120
Rated motor
PM240-2 (LO power + MLFB) PM240P-2 (LO power + MLFB) Booksize Motor Module
load
0.55 0.55kW / 6SL3210-1PE11-8■L1 3.0/ 6SL312■-1TE13-0AA3
0.75 0.75kW / 6SL3210-1PE12-3■L1
1.10
2.20
3
4 4kW / 6SL3210-1PE21-1■L0
5.5 5.5kW / 6SL3210-1PE21-4■L0 18/ 6SL312■-1TE21-8AA3
7.5 7.5kW / 6SL3210-1PE21-8■L0 18/ 6SL312■-1TE21-8AA3
11 11kW / 6SL3210-1PE22-7■L0 30/ 6SL312■-1TE23-0AA3
15 15kW / 6SL3210-1PE23-3■L0 45/ 6SL312■-1TE24-5AA3
18.5 18.5kW / 6SL3210-1PE23-8■L0 22kW / 6SL3210-1RE24-5■L0 45/ 6SL312■-1TE24-5AA3
22 22kW / 6SL3210-1PE24-5■L0 30kW / 6SL3210-1RE26-0■L0 60/ 6SL312■-1TE26-0AA3
30 30kW / 6SL3210-1PE26-0■L0 37kW / 6SL3210-1RE27-5■L0 85/ 6SL312■-1TE28-5AA3
Reluctance
*
91.9 92.6 93.5 93.9 94.2 94.5 94.9 Efficiency at the rated operating point +
Efficiency
IE4* 90.7 91.5 92.3 93.0 93.3 93.7 94.1 • At the rated operating point, the efficiency of a drive
System with
IE3* 88.0 89.0 90.1 90.9 91.5 92.0 92.6 system with reluctance motor is higher than a drive
reluctance motor IE2* 85.9 87.0 88.4 89.2 89.9 90.3 91.1 system with IE4 induction motor
1
System with
induction motor
2
Efficiency in the partial load range +
• In the partial load range, the efficiency of a drive
system with reluctance motor is significantly higher
than a drive system with IE4 induction motor
Thermal
Torque reduction +
Utilization
utilization
at rated power
F acc. to B • As a result of the thermal reserves, synchronous
reluctance motors can be operated down to 1/10 of
their rated speed with full torque – torque derating is
not required
200 1:10
150 Induction motor
22 kW
100
Load characteristic 97Nm, 150 – 1500 rpm
50
0
0 150 300 450 600 750 900 1.050 1.200 1.350 1.500 1.650 1.800 1.950 2.100 2.250
Speed rpm
200 1:10
150
Reluctance motor
100 15 kW
Load characteristic 97Nm, 150 – 1500 rpm
50
0
0 150 300 450 600 750 900 1.050 1.200 1.350 1.500 1.650 1.800 1.950 2.100 2.250
Speed rpm
200 1:10
150
Reluctance motor
Load characteristic +20%
15 kW
100
Load characteristic 97Nm, 150 – 1500 rpm
50
0
0 150 300 450 600 750 900 1.050 1.200 1.350 1.500 1.650 1.800 1.950 2.100 2.250
Speed rpm
Converter functionality +
• Drive shutdown depending on the process (hibernation mode)
• Control, converter and line motors (cascade/staging circuit)
• Flying restart circuit for fan drives, connecting to a drive, even if it is rotating
in the opposite direction
Handling +
• Synchronous reluctance motors are compatible to existing induction motors
regarding flange and shaft dimensions
Thermal behavior +
• Torque does not have to be reduced in the control range 1:10; as a
consequence, overdimensioning is not required, as is the case for induction
motors
• Continuous overload capability of 20% possible in a control range of 1:10
Converter functionality +
• The pole position identification avoids jerky forward/backward motion when
switching on
• The starting torque is 150 % of the motor torque
Productmanager Sinamics