BGHandbook SingleFamily

Download as pdf or txt
Download as pdf or txt
You are on page 1of 201

A Handbook for

A Green Building
Program
Developed by Builders for Builders

December 2013

Copyright © 2013 by Built Green Washington. All rights reserved. No part of this publication may be reproduced or
transmitted in any form, or by any means, electronic or mechanical, including photocopy, recording, and any
information retrieval system, without the written permission of the copyright holders.

1
Table of Contents
INTRODUCTION ... ………………………………………………………………………………………………………4
Handbook Organization ......................................................................................................... 4
How to use the Handbook ...................................................................................................... 4
PREREQUISITES ......................................................................................................................... 6
Meet Selected Star-Level Requirements .................................................................................. 7
Conform to the Housing Size Matrix ........................................................................................ 7
SECTION 1: BUILT GREEN TEAM .................................................................................................. 8
SECTION TWO: SITE AND WATER............................................................................................... 10
Site Protection ..................................................................................................................... 10
Water Protection ................................................................................................................. 39
Extra Credit for Site and Water .............................................................................................. 55
SECTION 3: ENERGY EFFICIENCY .............................................................................................. 56
Overall ................................................................................................................................ 57
Envelope ............................................................................................................................. 58
Heating/Cooling System ....................................................................................................... 79
Water Heating ..................................................................................................................... 87
Lighting ............................................................................................................................... 92
Alternative Energy ............................................................................................................... 99
Extra Credit for Energy Efficiency ........................................................................................ 100
SECTION 4: HEALTH AND INDOOR AIR QUALITY ..................................................................... 100
Overall .............................................................................................................................. 102
Jobsite Operations ............................................................................................................. 103
Layout And Material Selection ............................................................................................ 109
Moisture Control ................................................................................................................ 119
Air Distribution And Filtration ............................................................................................. 126
HVAC Equipment ............................................................................................................... 130
Indoor Pollutant Control ......................................................................................................133
Building Entrance Pollutants Control ................................................................................... 134
Extra Credit For Health And Indoor Air Quality ..................................................................... 135
SECTION FIVE: MATERIALS EFFICIENCY ................................................................................. 136
Overall .............................................................................................................................. 136
Reduce .............................................................................................................................. 137
Use Salvaged Materials ...................................................................................................... 139
Recycling ........................................................................................................................... 141
Design And Material Selection ............................................................................................ 146
Extra Credit for Materials Efficiency..................................................................................... 182
SECTION 6: OPERATION, MAINTENANCE & HOMEOWNER EDUCATION .................................. 183
SECTION 7: BUILT GREEN BRAND PROMOTION ....................................................................... 186

2
APPENDIX .............................................................................................................................. 187
Table 0-2 Energy Benchmarks to meet Built Green 3-, 4-, and 5-Star Built Green .................... 190
Chart 3-A Built Green Component Performance Method ....................................................... 191
Chart 3-B Built Green Prescriptive Scouring Method; Upgrades for all Fuel Types ................... 192
Built Green Jobsite Recycling Plan ....................................................................................... 195
Contractors’ Waste Reduction Resource Sheet ..................................................................... 196

3
Introduction

This Handbook contains specific, detailed information about each Action Item listed in the Single-
Family/Townhome New Construction Checklist.

Handbook Organization
The Handbook is organized into 3 parts: Introduction (this section), Action Items, an information section
containing narratives for each Action Item, and Appendix, containing tools that will help you with some
of the Action Items.

Action Items describes environmentally friendly Action Items arranged in seven categories:

• Built Green Team


A few Action Items that will help you build the right team for your Built Green project.
• Site and Water
BUILT GREEN offers a variety of common-sense site protection, water protection, and
development techniques you can use to earn points and be a “fish-friendly” builder.
• Energy Efficiency
This category promotes energy efficiency and improved comfort with Action Items intended to
push your project beyond Energy Code minimums.
• Health and Indoor Air Quality
Action Items in this category include selected practices to improve indoor air quality and reduce
health risks for occupants and installers.
• Materials Efficiency
Numerous options help you reduce job-site waste, saving both you and your customer money.
In addition to using materials efficiently, this section offers recognition for using a variety of “green”
building materials that are easier on the environment.
• Operation, Maintenance & Homeowner Education
The purpose of this section is to promote responsible homeowner operation and maintenance
throughout the life of the home, by equipping your clients to continue the good work you have
begun.
• Built Green Brand Promotion
Extra credit for innovation in marketing for Built Green brand.

Appendix provides charts and guidelines that will help you meet Action Items in the Energy Efficiency
and Material Efficiency sections.

How to use the Handbook


For ease of use, the Single Family/Townhome New Construction Checklist coordinates directly with the
Handbook Sections 1 – 7.

The checklists are “key-coded” to help you find information about each measure. The first number
indicates what section to look in, and the following numbers indicate the order in which it appears.
Here’s how it works, using an example Action Item from the Checklist:

In this example, the action “Use pervious materials for driveways, parking areas, walkways, and patios”
is described in Section Two (Site and Water), Action Item 44.

4
Number Possible CREDITS Point
Points Totals

2-44 2-6 Use pervious materials for driveways, parking areas,


walkways, and patios

HOW TO USE THE CHECKLIST

Action Item to be implemented

Order Action Item appears in Section (numerical)

Section where Action Item description appears


Point value of Action Item
(when range of points, refer to Part I narrative.)

Check () or enter Points when completed

5
PREREQUISITES

Meet selected star-level requirements

Category Possible Credit


Points
ONE-STAR REQUIREMENTS (100 points minimum)

required Conform to the House Size Matrix (Table 0-1)


required Meet all applicable codes and regulations
required Program Orientation (one time only)
Site & Water required Prohibit burying of construction waste

Energy required Achieve 5% improvement over Washington State Energy code (2012)

Site & Water required Stabilize all construction entrances with quarry spall or crushed rock

IAQ required Ensure proper drainage of crawl space


IAQ required All spot fans under 110 CFM are 1.5 sones or less
Materials required Post and implement a jobsite recycling plan

required Provide a building owner’s manual in accordance with credit 6-1


required Achieve a minimum of 15 points in each of sections 2-5

TWO-STAR REQUIREMENTS (200 points minimum)


required Meet all 1-Star requirements
Energy required Achieve 10% improvement over Washington State Energy code (2012)

required Achieve a minimum of 25 points in each of sections 2-5

THREE-STAR REQUIREMENTS (300 points minimum)


required Meet all 2-Star requirements
Energy required 15% energy use improvement over State Energy Code (2012)
required Achieve a minimum of 40 points in each of sections 2-5

FOUR-STAR REQUIREMENTS (400 points minimum)


required Meet 3-Star requirements
rd
required 3 party verification required (See reference)
required Achieve a minimum of 60 points in each of sections 2-5
Site & Water required No zinc galvanized ridge caps, copper flashing or copper wires for moss
prevention
Site & Water required Landscape with plants appropriate for site topography and soil types,
emphasizing use of plants with low watering requirements [drought tolerant]

Site & Water required Use the most efficient aerator available for kitchen faucets, lavatory faucets and
showerheads

6
Energy required Achieve 20% improvement over Washington State Energy code (2012) (See Table
0-2 in Appendix)
IAQ required Use low toxic/low VOC paint on all major surfaces
IAQ required Ventilate with box fans in windows blowing out during drywall sanding and new
wet finish applications
IAQ Use no products that contain added urea formaldehyde for any interior
applications
Materials required Practice waste prevention and recycling and buy recycled products (Section 5)

Materials required Achieve a minimum recycling rate of 50% of waste by weight

FIVE-STAR REQUIREMENTS (600 points minimum)


required Meet 4-Star requirements plus point minimum
required Achieve a minimum of 100 points in each of sections 2-5
Site & Water required Amend disturbed soil with compost to a depth of 10 to 12 inches to restore soil
environmental functions (2-34)
Site & Water required Use pervious materials for at least one-third of total area for driveways,
walkways, and patios (See Action item 2-44)
Site & Water required Limit use of turf grass to 25% of landscaped area (2-61)

Site & Water required Avoid soil compaction by limiting heavy equipment use to building footprint and
construction entrance (2-19)
Site & Water required Preserve existing native vegetation as landscaping (2-21)

Site & Water required Retain 30% of the trees located on site at the start of construction or,
alternatively, achieve a Green Factor score or .6 or higher (2-23)
Energy required Pre-wire for future PV installation (3-93)
Energy required Achieve 30% improvement over Washington State Energy code (2012) (See Table
0-2 in Appendix)
IAQ required Detached or no garage OR garage air sealed from house with automatic exhaust
fan (4-27)
Materials required Achieve a minimum recycling rate of 70% of waste by weight

Materials required Use a minimum of 10 materials with recycled content

Conform to the House Size Matrix (Square Feet Limit Refers to Conditioned Space)
See the following tables to calculate your point totals. Program note: For multiple projects in the same
community or plat, one checklist can be submitted IF the total point score on the BUILT GREEN checklist
for each floor plan varies by less than 10%. THE House Size multiplier, however, must be calculated
separately for each floor plan.

The most direct approach to resource efficiency is to build a smaller house. Although smaller houses
generally cost less to build and operate, the national trend has been toward larger houses. In 1949, the
average residence in the United States (not including the garage) was less than 900 square feet and
housed 4.2 people. In 1991, the typical 2,000-square-foot residence housed only 2.6 people.

Larger homes tend to consume proportionally more materials because they include more features.
Downsizing a conventionally framed house by 25% can save even more wood than substituting the
most wood-efficient advanced framing (see Action item 3-23, Use Advanced Wall Framing—24-in OC,
w/Double Top Plate). Smaller houses inherently reduce the embodied energy of a home (the total
amount of energy used to extract, refine, produce, and distribute materials from their point of origin to
7
installation and then ultimately to disposal). Small houses can be made space-efficient, functional, and
livable through careful layout and design. Fortunately, there are a number of excellent resources
available on compact house design.

Besides the size of a house, the shape of a house is one of the main factors in construction expenses.
Complicated angles and shapes significantly increase the cost of the building. Also keep in mind it may
cost less to build up than to build out, depending on local land and labor costs. Starting out with the
most appropriate size and shape for your house reduces the costs of almost all aspects of construction,
including waste disposal.

BUILT GREEN House Size Matrix

• Smaller houses use a multiplier for their overall points based on SF size.
• Larger houses are required to earn a minimum of points in the energy and materials section.
(Points listed are for each section)
• Project size to include all conditioned space of house except for an Additional Dwelling Unit
(ADU)

Table 0-1 House Size Matrix

Smaller houses use a multiplier for their overall points based on SF size.
Larger houses are required to earn a minimum of points in the energy and materials section. (Points listed are for each section)
Project size to include all conditioned space of house except for an Additional Dwelling Unit (ADU)

Bedrooms Multiplier min. min.


points req points
in energy req in
1 2 3 4 5 6 section** materials
section**
<500 <700 <900 <1300 <1900 <2400 1.20 N/A N/A
501- 800 701-1000 901-1200 1301-1750 1901-2350 2401-2700 1.15 N/A N/A
801-1200 1001-1400 1201-1800 1751-2350 2351-2950 2701-3500 1.10 N/A N/A
1201-1600 1401-1800 1801-2400 2351-3000 2951-3600 3501-4300 1.05 N/A N/A
SF

1600 1800 2400 3000 3600 4300 1.00 0 0


1601-1800 1801-2000 2401-2700 3001-3400 3601-4000 4301-4700 1.00 25* 25
1801-2000 2001-2200 2701-3000 3401-3800 4001-4400 4701-5100 1.00 35*+ 35+
2001-2200 2201-2400 3001-3300 3801-4200 4401-4800 5101-5500 1.00 45*+ 45+
>2200 >2400 >3300 >4200 >4800 >5500 1.00 55*+ 55+
= 2005 avg. Home size in WA State
* Energy Star Certification can be substituted for the required point minimum

Section 1 BUILT GREEN TEAM

1-1 Use Built Green member subcontractors, vendors, service providers, and
real estate agents
1-10 POINTS

1 POINT PER MEMBER BUSINESS USED

Seek out Built Green members for all aspects of home design and construction. Built Green membership
is open to licensed builders, developers, contractors, architects, and other building industry
8
professionals. Realtors and other stakeholders may join as Program Associates. Contact the MBA office
for a list of members:

1-2
A. Incorporate Built Green early in the design by conducting an eco-charrette
with the homeowner & team to determine Built Green features to be
included in the home.
B. Identify team member roles and how they relate to various phases of
green lot design, prep and development
C. Create a mission statement that includes the projects goals and objectives
5 POINTS

Conduct an eco-charrette with the homeowner before the project has begun, using the Checklist to
determine Built Green features to be included in the home. Goal setting and commitment to a green
approach to the project can help ensure successful implementation of green strategies and actions.
Review this checklist with all parties (e.g. owner, designer, engineer, general contractor, landscape
professional) at an early stage in the design process. An integrated approach can help find innovative
solutions, and ensure that team members are not working at cross purposes.

A knowledgeable team is established and team member roles are identified with respect to lot design,
preparation, and development. A written mission statement that includes the project's goals and
objectives is developed.

One of the earliest challenges for a builder in developing a green lot is assembling an effective team to
help the builder implement best green practices throughout the process. Examples of possible team
members include staff, site superintendents, utilities, excavators, landscape architects, wildlife
biologists, ecologists, and arborists.

Those involved in the development phase must understand what the mission of the site is, what it
means to be a green lot, and why green practices should be followed. Once the green intent of the
builder is communicated to the lot development team, the builder should work with the team
throughout the development process to identify and delegate responsibilities of team members, as well
as facilitate coordination between the members to achieve best green practices.

Resources
• American Society of Consulting Arborists, http://www.asca-consultants.org/why.html
• American Society of Landscape Architects, http://www.asla.org/members/pigroups.cfm
• International Society of Arboriculture, http://www.isa-arbor.com/home.asp
• Society of American Foresters, http://www.safnet.org/certifiedforester/
• The Ecological Society of America, http://www.esa.org/

SIGN:

1-3 Provide all documentation/copies to third-party verifier electronically


1 POINT

9
Section 2 SITE & WATER

General Resources
• Environmental Handbook for Washington Construction Contractors: Regulatory Guidance (Publication #96-503), Solid Waste and
Financial Assistance Program, Washington State Department of Ecology. 360-407-7472 or www.wa.gov/ecology/pubs.html.
• Watershed Protection Tools, Center for Watershed Protection, Ellicott City, MD. 410-461-8323 or www.cwp.org, multiple
publications including Site Planning for Urban Stream Protection.

Product Information
GreenSpec – The Environmental Building News Product Directory and Guidelines Specifications, E Build, Inc., Brattleboro, VT, 1999.
802-257-7300 or www.buildinggreen.com. GreenSpec is organized in standard CSI divisions. Environmental Building News (EBN)
also offers product reviews, information and lists some articles at the following web address:
www.buildinggreen.com/products/productslist.html.

Surface Water Management


On-Site Residential Stormwater Management Alternatives. Washington State Department of Ecology, 1995. 360-407-7472 or
www.wa.gov/ecology/pubs.html. Prepared by UW Department of Civil Engineering (Stephen Burges).
Stormwater and Urban Runoff Seminars—Guide for Builders and Developers, NAHB, Edited by Susan Asmus, Washington DC,
800-368-5242 x538 or www.nahb.com.
Stormwater Erosion and Sediment Control for Small Parcel Construction (WQ-R-93-012, Report #3 of 5). Washington State
Department of Ecology, Water Quality Program. 360-407-7472 or
https://fortress.wa.gov/ecy/publications/publications/wqr93012.pdf.
Keep it On Site! Residential Builder’s Guide to Small Site Erosion Control and Stormwater Management, 1999. Prepared by O’Brien
& Company for Kitsap County. Available at the BUILT GREEN Resource Library.
“Stormwater Management: Environmentally Sound Approaches,” Environmental Building News, Sept/Oct 1994. 802-257-7300 or
www.buildinggreen.com.
Stormwater Management For Construction Activities: Developing Pollution Prevention Plans And Best Management Practices:
Summary Guidance. EPA#833-R-92-001, October 1992, EPA Office of Wastewater Management, 401 M St. SW, Mail Code EN-336,
Washington DC, 20460. 800-245-6510, 202-260-7786 or http://cfpub.epa.gov/npdes/stormwater/menuofbmps/index.cfm.
For more information about National Pollutant Discharge Elimination System (NPDES), see http://cfpub.epa.gov/npdes/index.cfm
Stormwater Management Manual for Western Washington, Volume V, Runoff Treatment BMP’s Publication No. 05-10-33, Washington
State Department of Ecology, 2012, Full document can be viewed and downloaded from
http://www.ecy.wa.gov/programs/wq/stormwater/manual.html or call 360-407-6614.
Stormwater Management Manual for Western Washington, Volume II, Construction Stormwater Pollution Prevention. Washington
State Department of Ecology, Water Division. 2012. Full document can be viewed and downloaded from
http://www.ecy.wa.gov/programs/wq/stormwater/manual.html or call 360-407-6614.
International Erosion Control Association (IECA). 800-455-4322 or www.ieca.org. Provides technical assistance and an annual
Erosion Control Products and Services Directory. IECA’s Western Chapter addresses issues that are unique to the Western U.S

SITE PROTECTION
Proximity

2-1 Locate site within one of the Urban Growth Area (UGA) designated areas
5 POINTS

10
Overall

2-2 Build on infill lot to take advantage of existing infrastructure, reduce


development of virgin sites
5 POINTS

This credit is not applicable for homes in newly developed communities on greenfield sites.

Infill lots are developed areas with municipal water and sewer, electricity, and roads already available, excluding
lots in designated critical areas or overly steep slopes.

In those cases where a building already exists on the lot, BUILT GREEN encourages using the existing structures if
possible through renovation as the primary objective. However, if renovation is not possible, because the building
is not structurally sound, then salvage and recycling demolition materials becomes the secondary goal. The
measure is not intended to promote the razing of structurally sound structures to make way for larger buildings.
Restoring homes on infills as opposed to razing an existing home, and building a new larger home can have
dramatic benefits in reducing traffic and protecting habitat.

Resources
• “Designed to Fit,” by Susan Jenkins, Builder, July 1998, pp. 136-148. Washington, DC,
www.builderonline.com. (Four projects that demonstrate different forms of infill housing: attached,
detached, high-density, and low-density).
• “Infill Housing That Fits,” by Jamie Fisher, Journal of Light Construction, June 1998, p. 21. Williston, VT. 802-
859-3669 or www.jlconline. Order by phone or online at www.jlconline.com/bookstore.
• Policy Link, Equitable Development Toolkit, Infill Incentives, http://www.policylink.org/EDTK/Infill/

• Northeast-Midwest Institute and Congress for the New Urbanism, Strategies for Successful Infill
Development (2001), http://www.nemw.org/infillbook.htm

2-3 Build on a greyfield lot


5 POINTS

Redevelopment of a Greyfield site can provide an efficient use of land and infrastructure. Greyfield redevelopment
allows for the preservation of open space and wildlife habitat in the midst of growth.

Within these guidelines, a Greyfield site is defined as any site previously developed with at least 50% of the
surface area covered with impervious material. The development of a Greyfield site can be daunting, but local or
national incentives may exist to reward those builders who go through the process. Incentives may include the
elimination of development related fees, contribution from the local government in the development of off-site
improvements, and tax breaks. For more information, contact the Congress for the New Urbanism, Urban Land
Institute, American Planning Association, or the International Council of Shopping Centers.

Resources

• Urban Land Institute, www.uli.org


• American Planning Association, www.planning.org

• International Council of Shopping Centers, www.icsc.org

• Congress for the New Urbanism and PricewaterhouseCoopers, Greyfields into Goldfields: From Falling
Shopping Centers to Great Neighborhoods (February 2001),
http://www.cnu.org/cnu_reports/Executive_summary.pdf
11
• Congress for the New Urbanism and PricewaterhouseCoopers, Greyfield Regional Mall Study (January
2001), http://www.cnu.org/cnu_reports/Greyfield_Feb_01.pdf

2-4 Build on an EPA-recognized brownfield lot


5 POINTS

Remediation of a Brownfield lot results in the environmental restoration of a polluted site, a transformation that
makes an abandoned site habitable. Like Greyfield and infill development, Brownfield development provides an
efficient use of land and infrastructure while allowing for the preservation of open space and wildlife habitat.

The U.S. Environmental Protection Agency (EPA) characterizes Brownfields as ―real property, the expansion,
redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous
substance, pollutant, or contaminant. The EPA estimates that there are 450,000 such sites around the country.
Grants, loans, and training are available through the EPA’s Brownfield Initiative to assist builders and developers in
the remediation and development of Brownfield sites.

Resources

• U.S. Environmental Protection Agency, Brownfields Cleanup and Redevelopment:


http://www.epa.gov/Brownfields/index.html
• U.S. Environmental Protection Agency has introduced two Web-based tools to give the public additional
access to information about Brownfield properties and cleanup efforts. The tools allow residents to locate
Brownfields in their area and provide access to information about cleanup grants. -
www.epa.gov/Brownfields/bfwhere.htm

2-5 An adaptive reuse lot is selected


5 POINTS

Use a previously developed lot for a new purpose.

2-6 Build in a Built Green development


10 POINTS

Points cannot be combined Build in a Built Green or similarly certified development, such as LEED for
Neighborhood Development (LEED ND), or LEED for communities. The Built Green Communities program and
other similar programs promote voluntary land-use and community design guidelines which minimize
environmental impact and promote the responsible community design to benefit all citizens. Objectives include
preserving natural resources; balancing open space and density; reducing infrastructure costs through efficient
design; reducing automobile usage, encouraging cost effective, innovative ideas and technologies; and creating
diverse housing options. Refer to the Built Green Washington or USGBC website for a list of registered Built Green
Communities and LEED ND projects, www.builtgreenwashington.org, www.usgbc.org.

2-7 Use an alternative foundation system that minimizes volume of foundation


material and disturbance to soil and/or to water flow, for at least 50% of the
foundation
5 POINTS

Low impact foundation systems or integrated pre-cast footings requires little to no excavation, and provide the
following benefits

• Preserves site top soil

12
• Avoids expensive and time-consuming erosion preventions measures and drainage controls
• Maintains historic stormwater flows and natural topography on the site
• Affords an opportunity to help preserve salmon streams.
PIN Foundation Systems do not require traditional site excavation; instead Pin Foundation’s FootPrint system
involves pouring concrete into custom-designed forms that create a home’s foundation, then driving 5-to-9-foot-
long steel pins diagonally through both sides of the concrete to anchor it securely to the ground. The advantage of
the foundation system is that the original soil is preserved without being disturbed.

PIN Foundations may cost up to 10% more than conventional foundations with excavation. If incorporated early in
the planning stage, the reduction of site development costs coupled with an increase in environmental
compliance that will result in a positive permitting process, and an opportunity to gain more Action items points –
See Section Two Protect Natural Processes on Site.

Post and Pier foundations also offer the environmental benefit of minimizing excavation. Large beams run under
the home’s floor joists and are held up by posts. Each posts rests on a separate concrete footing or pier. Be sure to
consider seismic affects in design.

2-8 Build in a low-impact development


5 POINTS

Low Impact Development (LID) is a stormwater management strategy which uses various land planning and
design practices and technologies to simultaneously conserve natural resource systems and reduce infrastructure
costs. LID allows land to be developed, but in a cost-effective manner that helps mitigate potential environmental
impacts. LID uses Best Management Practices (BMPs) that replicate pre-development hydrologic conditions. For
additional information about LID, see The Low Impact Development Center, Inc. website,
www.lowimpactdevelopment.org or U.S. EPA website, www.epa.gov/nps/lid.

2-9 Build in a rural cluster development (RCD)


4 POINTS

Large-lot (10-acre) zoning has been the conventional way to minimize population density and retain rural
character in Spokane County’s rural areas. This method, while effective at controlling population density, has
divided our rural lands with little sensitivity to the effects on rural resources and the natural environment. Large-
lot zoning, combined with a lack of adequate road standards, has also created many miles of poorly maintained
private roads, making fire and emergency access difficult.

Rural residential clustering provisions provide an alternative to conventional large-lot zoning. Rural clustering
encourages the grouping of home sites on areas of the site that are best suited for development, while retaining
the remainder of the site for open space. Appropriately designed cluster developments can preserve active
agricultural and forestry uses as well as protect sensitive environmental areas.

13
Figure 2-1 Examples of Rural Residential Development

Lot Design

2-10 Self-conduct a site inventory and assessment


3 POINTS

2-11 Complete a natural resources inventory under the direction of qualified


professional
5 POINTS

The National Resources Inventory (NRI) is defined by the Natural Resources Conservation Services as “a
statistically based sample of land use and natural resource conditions and trends on U.S. nonfederal lands.”

The uses of the inventory are to:

• Determine the current or future, use, needs or protection of natural or man -made resources;
• Provide scientific basis for decision making about both regulatory and non -regulatory approaches;
• to preserve natural resources;
• To show the location and extent of existing resources, such as farmlands, surface and ground waters, and
related features.
14
Resources
• Tree Care Industry Association, http://www.treecareindustry.org/public/gov_standards_a300.htm
• Natural Resources Conservation Service, http://www.wa.nrcs.usda.gov/technical/NRI/index.html
• Tree Protection during Construction, Owen E. Dell, landscape architect and contractor, P.O. Box 30433,
Santa Barbara, CA 93130, 805-962-3253. Fact sheet with tips for making decisions about trees during site
evaluation, design and construction.
• Pacific Northwest Chapter, International Society of Arboriculture, Silverton, OR. 503-874-8263, fax 503-
874-1509, or e-mail info@pnwisa.org. Website, www.pnwisa.org/ provides lists of area certified arborists.
• Cooling Our Communities—A Guidebook on Tree Planting and Light-Colored Surfacing, Lawrence
Berkeley Laboratory Report LBL-31587 (1992). To order, write to Superintendent of Documents (GPO
Document #055-000-00371-8), PO Box 371954, Pittsburgh, PA 15220-7954. Attn: New Orders. Also
available from Iris Communications, Eugene, OR, 800-346-0104 or www.oikos.com.

2-12 Conduct a third party review of the site development plan for critical areas and
habitat protection (e.g. botanist, arborist, landscape architect)
5 POINTS

Resources
See Resources from Action item 2-11 above

2-13 Implement a plan to conserve the elements identified by the resource inventory
as high priority resources. Create a protection and maintenance plan for priority
natural resources/areas during construction
6 POINTS

A Plan is Implemented to Conserve the Elements Identified by the Resource Inventory as High Priority Resources.
Create a Protection and Maintenance Plan for Priority Natural Resources / Areas During Construction.

Resources
See Resources from Action item 2-11 above

2-14 All tree pruning on site is conducted by or supervised by a Certified Arborist


2 POINTS

Resources
See Resources from Action item 2-11 above

2-15 Basic training in tree or other natural resource protection is provided for the on-
site supervisor
3 POINTS

Resources
See Resources from Action item 2-11 above

15
Slope Disturbance

2-16 Long-term erosion effects are reduced through the design and implementation
of terracing, retaining walls, landscaping, and restabilization techniques
6 POINTS

Defensible Space Precautions

2-17 Landscape fire buffer around house using native species that are fire resistant
1 POINT FOR PER METHOD
3 POINTS MAXIMUM

Homes built at the interface between wildlands and urban areas face the threat of wildfires. While wildfires are a
natural part of Inland Northwest ecosystems, they can destroy life and property. There are many ways that home
designers, builders, and owners can prevent homes from igniting. Actions taken to reduce ignition are directed to
the area immediately surrounding a home; the home ignition zone. Defensible space zone: minimum 30-foot
buffer, (up to 100-foot for steeper ground).

Buffer Plantings:

• Foundation plantings: low growing, free of dead material, well watered


• Use grey water or reclaimed water to keep landscaped areas well watered. (Check with local municipalities
for water re-use regulations.)
• Maintain and water fire resistant plants and lawn. For plant material suggestions for the Inland West, see
HTTP://WWW.CNR.UIDAHO.EDU/EXTFOREST/FIREPROTECTBRO.PDF (University of Idaho: Moscow
Idaho)
• Use hardscape features for firebreaks around the home: driveways, gravel, concrete or paved walks and
patios
• Raised beds made from non-flammable materials (rocks, brick)
• Use gravel instead of bark mulch against any structures and under decks
• Store firewood 30-100 feet away from any structure; keep vegetation away from pile
• Replace wooden patio furniture with ones made from nonflammable materials (metal and glass)
• Replace wood shake roofs with fire resistant materials

2-18 Reduce fire danger by removing underbrush and unhealthy vegetation on site
(perform all measures listed in handbook)
3 POINTS

Reducing the amount of unhealthy vegetation around a home will reduce the heat source and in turn limit the
possibility of ignition. Research shows that a high intensity wildfire burning 100-200 feet away will not ignite a
home’s wood walls. Consult with local fire district, DNR, Firewise, or other recognized fire authority for a
recommended vegetation plan.

Create a fire resistant landscape for the entire property:

• Remove highly flammable brush, dead trees and shrubs from at least 100 feet around all structures

16
• Clean pine needles, leaves, and debris from roof, gutters, decks, and yards
• Compost or recycle yard debris instead of burning vegetation
• Prune all dead branches and limbs of trees 6-15 feet from ground. Leave at least 50% of the live branches
on tree.
• Eliminate ladder fuels (vegetation structured like rungs of a ladder: leaves, grasses, small shrubs, large
shrubs, and trees)

Protect Site’s Natural Features

2-19 Avoid soil compaction by limiting heavy equipment use to building footprint and
construction entrances
3 POINTS

Compacted soils are less able to absorb water, resist plant root penetration, and lack the porosity needed for
adequate aeration. As a result, they tend to increase stormwater runoff, which disrupts the natural water cycle
and stream dynamics.

Limit compaction of site soils by restricting and clearly marking heavy equipment use areas. On the jobsite, limit
all vehicle traffic to designated areas, restrict parking vehicles on site, and arrange for particularly heavy vehicles
(concrete trucks, cranes, etc.) to avoid the need for large turn-around areas. If porous pavement is planned for the
driveway, that area should be left undisturbed during construction so that the subsoil is not compressed. An
alternate access road should be used for construction vehicles. To protect exposed soils from excess traffic, locate
equipment storage and job shack areas for easy access.

2-20 Trenching, significant changes in grade, and compaction of soil and critical root
zones in "tree save" areas are avoided
4 POINTS

2-21 Preserve existing native vegetation as landscaping


3 POINTS

Native vegetation is adapted to the Northwest climate of rainy wet winters and dry summers. Retaining native
vegetation in a landscape (rather than removing them and then replanting) also provides excellent erosion,
sediment, dust, and pollution control. Finally, native plants are more resistant to naturally occurring disease,
insects, and low levels of nutrients, thus reducing the need for fertilizer or pesticides.

During building layout, identify existing native plants, including trees and understory plants that you want to save.
Precautions during site preparation include:

• Clear only actual areas needed to install driveways, parking areas, and building foundations.
• Clearly mark areas to be graded on plans and field stake or flag on site.
• Identify or flag non-clearing buffers, open spaces, and setbacks from streams, wetlands, and steep slopes
as indicated on plat maps.
• Review site areas to be graded with excavation crew to ensure compliance with preservation plan.
• Fence critical areas, such as tree root zones, to prevent crushing or filling. See Action item 2-22 for more
information on protecting trees.

17
• If trees only (not understory) are designated for protection, hand clearing of understory will help protect
tree roots. Be careful, however, about exposing some trees by clearing around them—they may become
hazards in strong winds or rain. Check with an arborist.
• Check grading operations frequently to prevent accidental damage to marked areas.
• Never park heavy equipment or store heavy materials under trees. See Action item 2-19, Avoid Soil
Compaction by Limiting Heavy Equipment Use to Building Footprint and Construction Entrances.

Resources
Also see Resources for Action item 2-22. Resources on preservation include:

• Building Greener Neighborhoods: Trees as Part of the Plan (see Chapter 5: “The Construction Process”).
Available from American Forests, Washington, DC, 202-955-4500 or www.amfor.org. Also available from
NAHB. 800-223-2665 or www.builderbooks.com.
• “Preservation Specifications for New Construction Sites,” specs for protecting on-site vegetation. Isabelle
Greene & Associates, landscape architects, 2613 De la Vina St., Santa Barbara, CA 93105, 805-569-4045.
• Pacific Northwest Chapter, International Society of Arboriculture, Silverton, OR. 503-874-8263, fax 503-
874-1509, or e-mail info@pnwisa.org. Website www.teleport.com/~pnwisa/. Provides a list of certified
arborists in King and Snohomish Counties.

2-22 Take extra precautions to protect trees during construction


3 POINTS

If you are building in a development, work with your developer as soon as possible to arrange for tree retention.

Whenever possible, consult an arborist to select valuable individual trees for preservation. Keep all excavations,
equipment and debris away from trees at a distance two times the size of the canopy from the tree trunk (drip
line) when possible (this protects the root systems). If you must cut roots, cut as few as possible. Cut them cleanly.
Once you remove the tree, get the rootball into a moistened burlap sack as soon as possible and re-bury the roots.
(The roots begin to dry out almost immediately. Keeping the roots moist, preferably with the soil intact, helps
minimize the impact of transplanting.) Preserve most of the important feeder roots. Whenever possible, protect
entire stands of trees.

Post signs on trees to be saved, clearly indicating the tree’s monetary value (cost of replacement). Charge
subcontractor for tree damage based on these dollar values (optional).

Trees moderate surface temperatures, thereby reducing building heating and cooling requirements. Specifically,
they can increase savings on energy bills by providing shade in summer and wind protection in winter. Trees also
reduce stormwater runoff, reducing urban peak runoff, stabilizing soils, and preventing air pollution. All of which
have great economic value to cities. Another benefit is that trees provide habitat for local wildlife. Studies show
that a single mature tree can provide nearly $300 annually in energy and resource value in terms of cooling,
erosion and pollution control, and wildlife shelter. Trees may also protect some of your site’s critical features like
stream buffer zones.

In general, homes with mature trees sell for more money and at faster rates. According to 1,350 real estate agents
surveyed by Bank America Mortgage, more than 50% believe trees have a positive impact on potential buyers’
impressions of homes and neighborhoods. Additionally, 84% felt that a home with trees would be as much as 20%
more salable. A NAHB survey reported that 43% of home buyers paid up to $3,000 more, and 27% spent over
$5,000 extra for wooded lots. Studies in some regions of the country have found trees add as much as 30% to the
selling price of lots.

18
Table 2-1 Potential Problems Associated with a Few Specific Trees

Tree Type Potential Problems/Recommended Strategy

Dogwood They may not adjust to environmental changes as


Douglas Fir easily as other species. Keep disturbance of these
Maple Red Alder trees to a minimum.
Western Hemlock
Western Red Cedar
Pacific Silver Fir If very tall, they can tip over easily. Watch height.
Douglas Fir Thinning increases the possibility of tipping over.
Western Hemlock Keep stands of these trees dense.
Cottonwoods Water-seeking roots—These trees thrive well in high
Maples moisture areas but keep away from sewer lines and
Willows filter fields.
Grand Fir Keep stands of these trees dense, whether one type
Noble Fir or mixed varieties. These trees are very prone to
Pacific Dogwood disease caused by thinning or damage to any part of
Pacific Silver Fir the trees.
Red Alder
Sitka Spruce
Western Hemlock
Western Red Cedar

Resources
Resources on preservation include:

• “Tree Protection during Construction,” Owen E. Dell, landscape architect and contractor, P.O. Box 30433,
Santa Barbara, CA 93130, 805-962-3253. Fact sheet with tips for making decisions about trees during site
evaluation, design and construction.
• Pacific Northwest Chapter, International Society of Arboriculture, Silverton, OR. 503-874-8263, fax 503-
874-1509, or e-mail info@pnwisa.org. Website, www.teleport.com/~pnwisa/, provides lists of area
certified arborists.
• Cooling Our Communities—A Guidebook on Tree Planting and Light-Colored Surfacing, Lawrence Berkeley
Laboratory Report LBL-31587 (1992). To order, write to Superintendent of Documents (GPO Document
#055-000-00371-8), PO Box 371954, Pittsburgh, PA 15220-7954. Attn: New Orders. Also available from Iris
Communications, Eugene, OR, 800-346-0104 or shop.oikos.com/catalog.

2-23 Retain trees on site


1 POINT PER 20% PRESERVED
5 POINTS MAXIMUM

See Action item 2-22 above.

2-24 If building near wetlands, shorelines, bluffs, and other critical areas, preserve &
protect beyond code or local requirements
3 POINTS

19
Numerous federal, state and local laws affect the use and protection of wetlands and other critical areas. Because
of the considerable variation in local regulations, contact your local planning department to determine what
actions constitute going beyond code.

Wetlands and riparian areas provide essential cover, feeding, nesting and breeding habitat for many species of
fish and wildlife. They provide critical hydrological function by acting as a sponge, buffering the effects of storms
on creeks. This buffering effect allows peak velocities to be reduced during storm events and provides base flows
during dry times. Wetlands can also act as a natural recharge area for groundwater.

Protect wetlands and riparian areas from sediment using appropriate best management practices such as
compost slope mulching and silt retention berms. Leave a vegetated buffer zone, a minimum of 100 feet wide on
each side along streams or other water bodies unless approved plans indicate larger buffers are required. (Check
with your local jurisdiction for buffer size requirements.)

Steep slopes are inherently unstable areas. Careful management of site drainage is probably the most
cost-effective approach to minimizing bluff hazards. Even when circumstances dictate significant structural
stabilization efforts, site drainage remains an essential component of proper management.

Throughout the construction process, maintain erosion control measures. See Action items 2-29. Numerous
federal, state, and local laws affect the use and protection of wetlands and other critical areas. Because of the
considerable variation in local regulations, contact your local planning department for requirements.

Resources
• Protecting Natural Wetlands – A guide to Stormwater BMP’s, EPA, Office of Water (45 02F) Washington, DC,
EPA 843-13-96-001, October 1996. Call the Wetlands Hotline: 800-832-7828 or
www.epa.gov/region04/water/wetlands/technical/bilio-online.htm.
• Stabilization and Erosion Control Using Vegetation: A Manual of Practice for Coastal Property Owners.
Washington State Department of Ecology. 360-407-7472. Available on the “Surface Water and
Groundwater on Coastal Bluffs” website: www.wa.gov/ecology/sea/pubs/95-107/using01.html. This site
also contains information on drainage control, slope drainage, planning, case studies, links, and more.
• Vegetation Management: A Guide for Puget Sound Bluff Property Owners. Washington State Department of
Ecology, 360-407-7472, www.ecy.wa.gov/biblio/9331.html.

2-25 Set aside percentage of buildable site to be left undisturbed


1-5 POINTS

POINT ALLOCATION 1 POINT 3 POINTS 5 POINTS


FOR LOTS < 0.25 ACRES 10% 15% 20%
FOR LOTS UP TO 1 ACRE 20% 30% 40%
FOR LOTS BETWEEN 1-5 35% 50% 70%
ACRES

This Action item requires that you set aside a percentage of the site that will not be cleared or graded. Include any
critical areas in the set aside land area. The following points can be earned for setting aside undisturbed area:

Setting aside undisturbed areas helps preserve soil, water, and vegetation. Undisturbed areas stabilize soils and
filter sediments from storm water runoff before they enter waterways. They also allow rainwater to stay on site
and soak into the ground, recharging groundwater, instead of running off site. In addition, they provide a
cost-effective head start on landscaping. Preserving natural features can add landscape beauty, enhance fish and
wildlife habitat, and reduce noise. To ensure the benefit of this measure, set aside areas should be protected by
covenant.

Coordinate with the grading designer and equipment operators to let them know about this goal and to help you
come up with creative solutions. Review the set aside plans with subs, especially grading and excavation crews.

20
Resources
• Building Greener Neighborhoods: Trees as Part of the Plan (see Chapter 5: “The Construction Process”).
Available from American Forests, Washington, DC, 202-955-4500 or www.amfor.org. Also available from
NAHB: 800-223-2665 or www.builderbooks.com.
• The American Forests website, www.amfor.org, has information about CITYgreen, a GIS software that can
model and map the cost savings from maintaining trees for a small site, such as a new subdivision. Select
“Green Cities” option.

2-26 Measures are planned and implemented that will support wildlife habitat
4 POINTS

See Resources from Action item 2-11 above

2-27 Previously compromised environmentally sensitive areas are mitigated or


restored
5 POINTS

Protect Natural Processes On-Site

2-28 Natural water and drainage features are preserved and used
6 POINTS

2-29 Install and maintain temporary erosion control devices that significantly reduces
sediment discharge from the site beyond code requirements
2 POINTS

Erosion control best management practices (BMPs) are designed to minimize the loss of soil during construction.
Often, as construction projects get underway, BMPs are installed, but not maintained on a regular basis. Check
and maintain all BMP strategies regularly to avoid erosion. Better yet, provide back up to temporary control
devices for additional protection.

In large development projects, specific measures for stormwater collection, storage, and treatment are required
as part of the permitting process. The following are environmentally friendly approaches for any size
development.

• Use compost barriers or berms, or silt control fencing at appropriate locations (choose filter fabric with
proper porosity and ability to trap sediments for type of soil and its location). Recent studies by
Washington State Department of Transportation and others have found properly constructed compost
berms to be more effective and less costly than fabric fences for silt control.
• Install stabilized construction entrance (quarry spall or crushed rock). See Action item 2-19, Avoid Soil
Compaction by Limiting Heavy Equipment Use to Building Footprint and Construction Entrances.
• Protect adjacent and downstream properties from adverse effects of increased runoff.
• Mulch exposed soils or use plastic sheeting. See Action item 2-48, Preserve and cover topsoil on site for
reuse.

21
• Install temporary straw bale erosion and sedimentation control check dams in ditches during construction.
• Compost or hydroseed exposed areas as soon as possible.
Using compost for erosion control is a relatively new application (check with your local code enforcers and
stormwater management officials first). Slightly coarse to coarse types of compost are well suited for holding
surface soil in place even during heavy rainfall. See Action item 2-30, Use Compost to Stabilize Disturbed Slopes, for
more information on using compost.

2-30 Use compost to stabilize disturbed slopes


1 POINT

This credit is only available on sites with defined slopes.

Soil left exposed on slopes will erode. Research has shown that compost can often outperform conventional slope
stabilization methods.

Grade the slope to a ratio no steeper than 2 horizontal to 1 vertical (the maximum allowed by the UBC), or terrace
steeper slopes with retaining walls. Apply compost to cover the entire exposed soil surface, extending
approximately 3 feet over the top of the slope or meshing into existing vegetation. The compost application rate
will vary depending upon degree of slope, soil type, and compost characteristics. As a rule of thumb, however, a 3
to 4-inch layer of compost will effectively control erosion on a slope of up to 45% for between one and three
years.

Composts containing particles that range in size (½” or greater) will produce a more stable mat. Stable, relatively
dry yard trimmings compost will also filter and bind pollutants from stormwater, reintroduce organic material,
and enhance water retention/infiltration. Avoid very coarse composts if the slope is to be landscaped or seeded. In
environmentally sensitive areas or where water quality is a concern, use only compost made from yard trimmings,
uncontaminated wood by-product based materials, or well-stabilized biosolids.

Resources
• Field Guide to Compost Use, U.S. Composting Council, Alexandria, VA. 440-989-2748 or
compostingcouncil.org. Limited supplies available: read-only version on website.
• Summary of Projects Using Yard Debris Compost for Erosion Prevention and Control, Portland Metro,
Portland, OR. Available from Metro Regional Environmental Management, 600 NE Grand Ave., Portland,
OR 97232-2736, Attn: Records. Send $5.00 check for postage and handling.
Erosion control fabric:

There are a number of quality landscape fabrics available through local suppliers. When requesting a fabric, check
to see if a recycled-content option has become available locally. Some environmentally friendly erosion control
fabrics are:

• FibreNet, American Excelsior Co. 800-777-7645 (SOIL) or www.amerexcel.com. 100% biodegradable


erosion control netting.
• North American Green erosion control blankets made of wheat straw and coconut fiber, available at ACF
West, Portland, OR. 503-771-5115 or www.acfwest.com.
• BonTerra coconut or straw (or mixed) erosion control blankets, BonTerra America. 800-882-9489, e-mail:
bonterra@moscow.com, or www.bonterraamerica.com. Available through Layfield Plastics. 800-796-
6868 or www.geomembranes.com. Layfield carries other organic erosion control products for all
applications.
• “Landlok,” Synthetic Industries, Chattanooga, TN. 800-FIX-SOIL, 423-899-0444 or www.fixsoil.com.
Erosion control mats with 15% recycled content. Available through Northwest Linings. 800-729-6954.
• Fabriscape, Inc., Chicago, IL. 800-992-0551 or www.fabriscape.com. Supplier for landscape fabrics for a
variety of purposes, including slope containment. Check for environmentally friendly options.

22
Hydroseeding:

Specify hydro mulch with recycled cellulose:

• Fiber Mulch, Thermoguard. 800-541-0579 or 509-535-4500


• Nature’s Own, Hamilton Mfg. Inc. 208-733-9689 or www.hmmfg.com.
• Agri Fiber Mulch, Greenstone/LP Corp. 916-387-9754 or www.greenstone.com.
• Conwed Hydro-Mulch, Pacific Products. 888-933-7770.

2-31 Stabilize disturbed areas within 14 days that are complete or will be left
unworked for greater than 21 days using methods as recommended by the EPA
or in the approved storm water pollution prevention plan (SWPPP), where
required
3 POINTS

Bare soil will erode due to wind and water. Seed, replant, or cover exposed soils with compost, mulch, vegetation,
and/or matting as soon as practical. Use wildflower seeds appropriate for this region for color and interest, such as
along driveways. All disturbed areas should be treated in some way with landscaping, site features, or erosion
control devices.

Grade the slope to a ratio no steeper than 2 horizontal to 1 vertical (the maximum allowed by the UBC), or terrace
steeper slopes with retaining walls. Apply compost to cover the entire exposed soil surface, extending
approximately 3 feet over the top of the slope or meshing into existing vegetation. The compost application rate
will vary depending upon degree of slope, soil type, and compost characteristics. As a rule of thumb, however, a 3-
to 4-inch layer of compost will effectively control erosion on a slope of up to 45% for between one and three
years.

Composts containing particles that range in size (½ or greater) will produce a more stable mat. Stable, relatively
dry yard trimmings compost will also filter and bind pollutants from stormwater, reintroduce organic material,
and enhance water retention/infiltration. Avoid very coarse composts if the slope is to be landscaped or seeded. In
environmentally sensitive areas or where water quality is a concern, use only compost made from yard trimmings,
uncontaminated wood by-product based materials, or well-stabilized biosolids.

Resources
• Field Guide to Compost Use, U.S. Composting Council, Alexandria, VA. 440-989-2748 or
compostingcouncil.org. Limited supplies available: read-only version on website.
• Summary of Projects Using Yard Debris Compost for Erosion Prevention and Control, Portland Metro,
Portland, OR. Available from Metro Regional Environmental Management, 600 NE Grand Ave., Portland,
OR 97232-2736, Attn: Records. Send $5.00 check for postage and handling.
There are a number of quality landscape fabrics available through local suppliers. When requesting a fabric,
check to see if a recycled-content option has become available locally. Some environmentally friendly erosion
control fabrics are:
• FibreNet ™, American Excelsior Co. 800-777-7645 (SOIL) or www.amerexcel.com . 100% biodegradable
erosion control netting, also Recyclex® - permanent erosion control mat made from 100% recycled post-
consumer "green soda bottles." www.curlex.com/pro_recyclex.php.
• North American Green erosion control blankets made of wheat straw and coconut fiber, available at ACF
West, Portland, OR. 503-771-5115 or www.acfwest.com.
• BonTerra coconut or straw (or mixed) erosion control blankets, BonTerra America. 800-882-9489, e-mail:
bonterra@moscow.com, or www.bonterraamerica.com. Available through Layfield Plastics. 800-796-
6868 or www.geomembranes.com. Layfield carries other organic erosion control products for all
applications.

23
• Fabriscape, Inc., Chicago, IL. 800-992-0551 or www.fabriscape.com. Supplier for landscape fabrics for a
variety of purposes, including slope containment. Check for environmentally friendly options.
Specify hydro mulch with recycled cellulose:
• Fiber Mulch, Thermoguard. 800-541-0579 or 509-535-4500 (warehouse in Tukwila).
• Nature’s Own, Hamilton Mfg. Inc. 208-733-9689 or www.hmi-mfg.com/ec__.php.
• Conwed Hydro-Mulch, Pacific Products. 800-508-8681 or
www.conwedfibers.com/mulches/hydromulch2000.html. Call 800-336-1180 for a local distributor.

2-32 Balance cut and fill, while maintaining original topography


3 POINTS

Minimizing or balancing cut and fill avoids expensive exporting or importing of topsoil. If you need to import fill to
the site, use only approved materials for filling and grading. Avoid radically altering the basic topography to
maintain existing site hydrology as much as possible.

This credit is not applicable for fully excavated sites.

2-33 Limit grading to 15 feet around structures, septic, ground-source heat pump
fields, except for driveway access
4 POINTS

Soil that is compacted or contaminated by construction activity may become lifeless (see Action item 2-19, Avoid
Soil Compaction by Limiting Heavy Equipment Use to Building Footprint and Construction Entrances). Designing for
minimal grading helps retain healthy soil and natural water infiltration processes. Where grading is unavoidable,
carefully remove and stockpile existing topsoil (see Action item 2-48, Preserve and cover topsoil on site for reuse),
replacing it after rough grading.

This Action item is difficult to achieve on infill lots. In this case, apply 4” of compost to amend soils (see Action
item 2-30, Use Compost to Stabilize Disturbed Slopes).

Avoid disrupting existing drainage patterns and minimize grade changes where possible. Grading for stormwater
control should direct water to planted areas to minimize irrigation needs.

2-34 Amend disturbed soil with compost or suitable soil amendments to a minimum
depth of 10" to restore soil environmental functions
4 POINTS

Test soil by a reputable soil lab to get data about the site soil’s chemical and physical condition, as well as its
biological health. These labs will provide specific recommendations for optimum soil amendment. Amendments
may include sand or gravel for improved drainage, lime or other pH modifiers, or organic manure or compost to
improve nutrient availability. Compost amendments reduce summer irrigation demand, reduce stormwater runoff
and erosion, improve soil quality, and improve turf aesthetics.

Compost should be mature and stable. Ask your supplier for “Grade A” compost as defined by the Washington
State Department of Ecology’s Compost Guidelines. Mature composts settle less, provide stable nutrient sources,
bind metals, and provide higher levels of beneficial organisms.

As a rule of thumb, a 2 to 1 ratio of existing soil to compost, by loose volume, will achieve the desired organics
level of 8 to 13% by soil weight. The final depth of the amended soil will be between 10 to 12 inches, depending
upon the equipment you use.

Resources
24
• Washington Organic Recycling Council, website provides information on soil health and function, includes
resource list for compost specifications, erosion control, and case studies, http://www.soilsforsalmon.org/

2-35 Replant or donate removed vegetation for immediate reuse


2 POINTS

Plants and trees to be removed for construction can often be reused for landscaping on site. Replant as soon as
possible and make sure you follow appropriate procedures so plants survive. If you can’t replant immediately,
protect the root ball while waiting to replant and water as needed. See Action item 2-21 Preserve Existing Native
Vegetation as Landscaping.

Keep all excavations, equipment, and debris away from trees at a distance two times the size of the canopy from
the tree trunk (drip line) when possible to protect root systems. If roots must be cut, cut as few as possible and cut
cleanly. Immediately after removing the tree, transfer the root ball into a moistened burlap sack and re-bury the
roots. This action keeps roots from drying out, minimizing the impact of transplanting. Preserve most of the
important feeder roots. Whenever possible, protect entire stands of trees. For additional requirements, refer to
municipal code and standards.

Some nurseries participate with local organizations involved in restoration projects to salvage native plants from
development sites. See the Part II, Section Two Resources for this Action item for contact information.

25
2-36 Use plants donated from another site
2 POINTS

A developer can use plants/trees from other areas in the development or individual builders can work with local
developers or other builders, to secure plant material being removed from sites. Or you can use plants from
another of your projects.

2-37 Grind land clearing wood and stumps for reuse


3 POINTS

For builders working on multiple sites or large developments, grinding land cleared wood waste can be a
cost-effective way to reduce jobsite waste and provide opportunities to reuse the material as mulch (on site or at
other locations). Mulch can renew the soil by improving water and nutrient retention and can also be used to
protect stockpiled topsoil. See Action item 2-48, Preserve and cover topsoil on site for reuse.

Always meet dust control requirements. Check with local jurisdiction for dust control requirements for
construction projects.

Note: If grinder operates at a site for more than 30 days in a 12 month period, a permit may be required to
operate. Check regulations in your area.

Resources
Grinders generally handle 6-inch maximum diameter materials. A 10 x 10 woodpile can be reduced to mulch and
used to landscape the final project. Trees that are not ground can be cut for landscaping posts, fences, or
firewood. For local mobile grinding services see:

• Check the phone book under “Land Clearing” for additional mobile grinder operators in your area.

2-38 Use a water management system that allows groundwater to recharge on site
5 POINTS FOR 50%
10 POINTS FOR 100%

Groundwater is a resource that may have only minimal direct impact on a particular site, but its purity is an
important issue downslope where it seeps to the surface or is pumped out of the ground as potable water.
Groundwater is “recharged” from surface waters infiltrating into natural recharge areas. It is important to
understand the hydrology of your site so as not to interfere with these areas. See Resources Section for reference
to Surface Water Design Manual.

In addition to preserving groundwater recharge zones, landform engineering can help reestablish proper water
functions that may have been disrupted during site development. Landform engineering is the act of using the
natural movement of water while manipulating and enhancing existing topographic conditions to improve a site’s
ability to catch, hold, and absorb water, mimicking natural drainage features. Water storage and nutrient
collection processes contribute to forming a healthier ecological community within the landscape. This process
allows water to infiltrate into the ground and enrich the life of the soil ecology. Examples of landform engineering
that can contribute to a water management system include: mulching, contour trenches, swales and terraces,
check dams, dry wells and sand traps, retention basins, and diversion ponds. Other alternative strategies include
roof infiltration systems, level spreaders, and rainwater storage vaults or dispersion systems. These systems can
be used alone or in combination to put runoff back in the ground through infiltration or dispersion through natural
vegetation. Avoid directing runoff directly to a natural or constructed drainage system and keep runoff and
sediment on site.

Resources

26
See Resources, Surface Water Management, for sources of information related to stormwater management and
erosion control: particularly:

Landscape Plan

2-39 Species and locations for tree planting are identified that will provide summer
shading of the dwelling and parking areas to moderate temperatures
5 POINTS

Properly placed trees within the landscape can be as effective as other home improvements in reducing heating
and cooling costs. Good selection and placement of trees within the landscape can help cool your house in
summer and allow the sun to warm the house in winter.

Effective tree placement will allow the winter sun to warm the roof and walls of your house. Placing deciduous
trees that lose their canopy in the winter on the south side of the house allows solar access to these areas during
winter, and shade during the summer.

Using landscaping to create microclimates that either encourage or prevent wind, light, or water to reach certain
areas of the property can benefit on-site structures. Energy-conscious landscaping design can result in reduced
operational costs for the homeowner, greater comfort, and less energy use. Deciduous trees placed south and
west of the home can reduce heating and cooling loads by providing shading during hot summer days, and
allowing winter sun to penetrate windows. According to the U.S. Forest Service, trees properly placed around
buildings (see Figure 2-2) can reduce air conditioning needs by 30 % and can save 20-50% in energy used for
heating. Well-placed windbreaks of evergreens can reduce a building’s heating bill by up to 20%. Examples of
energy-saving design include:

• Maximum southern exposure with most windows facing south.


• Plantings on the east and northeast to filter the sun without blocking the light.
• Plantings on the south to create shade and channel breezes in summer without obstructing sun in winter.
• Mid-range colored materials for driveways, walkways, and parking spaces to reflect sun in summer and to
absorb and re-radiate heat in winter.
• Paved areas located away from south windows and shaded with plantings.

27
Figure 2-2 Tree Placement to Reduce Heating/Cooling Loads Naturally
(Source: Cool Communities, www.coolcommunities.org)

2-40 Vegetative wind breaks or channels are designed as appropriate to local


conditions
4 POINTS

2-41 Achieve a Green Factor Score for urban or infill under 1 acre
1 POINT FOR A SCORE OF 0.3
2 POINTS FOR A SCORE OF 0.4
3 POINTS FOR A SCORE OF 0.5
4 POINTS FOR A SCORE OF 0.6
5 POINTS FOR A SCORE OF 0.7

The Seattle Green Factor is a program that requires new development in neighborhood business districts to meet
a landscaping target using a menu of landscaping strategies that have been assigned variable points based on
their efficacy. The Green Factor is designed to improve the amount and quality of urban landscapes, while
allowing greater flexibility for developers and de-signers to meet open space requirements.

The Green Factor encourages layering of vegetation in areas visible to the public and in the public rights-of-way
directly adjacent to new development. The program works using a simple spread-sheet that assigns variable
points for different landscaping options. The values range from a factor of 0.2 to a factor of 0.7. Lower values
correspond to lawn and groundcovers, small plants, while larger trees and shrubs, depending on their sizes are
awarded higher corresponding point values. Bonuses are provided for rainwater harvesting and choosing plants
with low water requirements. Use of larger trees, tree preservation, green roofs, and vegetated walls trigger more
credits towards meeting a specific numerical target. A worksheet helps applicants calculate their project’s score,
allowing them to try different combinations of features to reach the requirement. The number of plants or the

28
square footage is multiplied by its point factor. Increasing plants or square footage will accomplish the aggregate
0.3 green factor.

In addition to being attractive, new green elements in the landscape will improve air quality and help reduce
energy consumption, cooling the city in the summer and insulating it in the winter. They will also reduce
stormwater runoff, decreasing water pollution and public infrastructure costs. For more information, see
HTTP://WWW.SEATTLE.GOV/DPD/CITYPLANNING/COMPLETEPROJECTSLIST/GREENFACTOR/

2-42 Plant only trees that when full grown still allow for future solar install on south-
side of property
3 POINTS

Impervious Surfaces

2-43 Install vegetated roof system (e.g. green roof) to reduce impervious surface
1 POINT PER 10% OF ROOF
10 POINTS MAXIMUM

Eco-roofs or green-roof systems are best suited for low-slope roofs. They are designed to protect the roof, permit
the use of rooftop plantings, provide energy benefits, and provide initial water quality benefits. More commonly
used in Europe, green-roofs can detain over 50% of rainwater from a typical storm. Stormwater detention reduces
the often-high loads placed on sewer systems after a rainfall. Recent studies conducted in Germany show that
green roofs can be effective in improving the quality of roof runoff.

Multi-layered green-roof systems are thicker than conventional roofs. Space must be allocated for the unusual
insulation and roofing membranes. A green-roof includes a synthetic waterproof membrane, a drainage layer, a
thin soil layer (2 to 4 inches), and a cover with specific plant species adapted to the extremes of a rooftop
environment. A thick sod of native grasses interspersed with wildflowers can be a wonderful architectural
element.

The green-roof can be very low maintenance, and is self-sustaining without need of irrigation, fertilizers, or
pesticides. The first cost may be about 50% more than a good quality conventional roof, but they last about twice
as long so they have a relatively low life cycle cost. They also help to reduce building heat gain and urban heat
islands (temperature differences between developed and undeveloped areas that can affect the microclimate and
human and wildlife habitat.). Additionally, the plantings absorb carbon dioxide. Consult an expert on installation
and maintenance needs.

To receive credit must be at least 25% of all structures.

29
Table 2-2 Comparisons of Eco roofs and Conventional Roofs
(Source: Tom Lipton, Spawning Great Ideas Proceedings)

Characteristic Eco-roof Conventional Roof


Stormwater Retention 15 to 35% in wet season, 65 to 100% in warm season None
Peak flow mitigation All storms None
Temperature All storms None
mitigation
Improves water Yes, retains atmospheric deposition and retards roof No
quality material degradation
Air Quality Filters air, prevents temperature increases, stores None
carbon
Energy Conservation Approaches predevelopment air/surface energy None
relationship; insulates structures
Vegetation Allows seasonal evapo-transpiration; provides None
photosynthesis, oxygen-carbon-water balance
Greenspace Can replace 100% of greenspace lost to building None
footprint, although greenspace quality may be lost
Habitat For some insects and birds None
Livability Buffers noise, eliminates glare, alternative aesthetic, None
offers passive recreation
Costs About 30 to 60% more expensive for construction Highly variable from $2 to
2
including retrofits $10/ft for new construction
2
and $4 to $5/ft for retrofits
Potential cost off-sets Energy savings, higher rental values, sewer fee None
reductions, reduced need for insulation materials,
reduced waste to landfills
Durability Waterproof membrane protected from solar and Little protection, exposure
temperature exposure, lasts more than 36 years, to elements, lasts less than
membrane protected from O&M staff damage 20 years
Maintenance Once or twice a year to tend plants, once a year to Once a year to assure drains
assure drains are not clogged and check for damage are not clogged and check
from O&M for damage from O&M

2-44 Use pervious materials for driveways, parking areas, walkways, and patios
2 POINTS PER 33% PERVIOUS ACHIEVED
6 POINTS MAXIMUM

Pervious paving materials help to maintain water hydrology of the site. Pervious paving materials may initially
cost more than conventional paving materials (such as asphalt), but pavement replacement is simplified, and
expensive measures such as asphalt cutting for underground repairs are eliminated. Examples of permeable
options include:

• Porous or “No Fines” concrete


• Uncompacted gravel (Note 1)
30
• Crushed stone (Note 1)
• Open or porous paving blocks
• A “Hollywood” driveway design (Note 2)
Notes:

1. Gravel or crushed stone is not considered pervious for driveways or parking areas. These materials will
generally compact under vehicle traffic, unless it is reinforced with a cellular containment product. Use
gravel and crushed stone for walkways and other light traffic areas.
2. A “Hollywood” driveway is made of 2 long strips of pavement for car support. The area between should
be vegetated (preferably with a low–grow turf) or filled with gravel. Vegetated strips provide some
infiltration of runoff, sediment filtering, and pollutant removal.

“Disconnecting” impervious surfaces on site is as important as the materials you select. Avoid situations in which
one impervious surface drains onto another impervious surface, which magnifies stormwater runoff problems. A
paved driveway, for example, should not drain onto a paved street. Try to separate impervious surfaces with areas
of turf, other vegetation, or gravel. Curbs should be avoided, and the paved surfaces and vegetate filter strip.
Filter strips should slope (no more than 5%) downhill away from the paved surfaces. Grass in these strips are to be
used as part of the stormwater conveyance system, or any ground cover (groundcover should be dense enough to
discourage channelizing and erosion).

Eliminate Water Pollutants during Construction


The Washington State Department of Ecology offers a variety of publications as part of their Hazardous Waste
and Toxics Reduction Program. To order, by telephone call 360-407-7472. Or see www.wa.gov/ecology/pubs.html
or e-mail ecypub@ecy.wa.gov. Recommended publications include (URL given where the publication is available
online):

• Free Help for Businesses (Publication #96-407). This fact sheet summarizes free technical assistance
offered by the DOE’s Hazardous Waste and Toxics Reduction Program. Available online at
www.wa.gov/ecology/pubs/96407.pdf.
• Hazardous Waste Generator Checklist (Publication #91-012b). This checklist will help you determine if your
business produces hazardous wastes and summarizes your responsibilities if you do.
• Hazardous Waste: More Common Than You Think (Publication #91-012a.) This report identifies businesses,
which generate hazardous waste, and gives examples of the different categories of hazardous waste. It
also offers suggestions about reducing and recycling hazardous waste.
• Hazardous Waste Service Providers Directory (Publication #98-412). This directory is intended to assist
hazardous waste generators to identify and contact businesses that will help manage hazardous wastes. It
also contains names and addresses for Moderate Risk Waste Coordinators listed by County and Native
American Tribal Contacts. Available online at www.wa.gov/ecology/pubs/98412.pdf.
• Pollution Prevention Planning Guidance Manual (Publication #91-2). Available online at
www.wa.gov/ecology/pubs/91002.pdf.
• Sara Title III, Emergency Planning and Community Right-to-Know, A Guide for Business (Publication #93-
BR-01). Available online at www.wa.gov/ecology/pubs/93br001.pdf.
• Site Hazard Assessment Guide (Publication #F-TC-91-111). This Washington State Department of Ecology
Focus Sheet relates to site hazard assessments, which is the first step in the process for cleaning up a
hazardous waste site.
• Step by Step: Fact Sheets for Hazardous Waste Generators (Publication #91-012). This packet of information
contains guidance for generators of hazardous waste. It includes the following information sheets: how to
identify hazardous waste; obtaining a RCRA identification number; filling out annual reports; performing
preventive maintenance; how to properly accumulate hazardous waste; planning for emergencies; using
and managing containers; arranging for proper transportation and disposal; manifesting shipments of
hazardous waste; and keeping records of hazardous waste activities.
31
• What is a Small Quantity Generator? Your Regulatory Status Under the Dangerous Waste Regulation
(Publication #96-404). This brochure offers an overview of the standards that apply to small quantity
generators. It also lists resources that can offer help. Available online at
www.wa.gov/ecology/pubs/96404.pdf.
Also see:

• The Regulation of Solid and Hazardous Wastes: A Builder’s Guide, NAHB Research Center, Upper Marlboro,
MD, 800-638-8556 or www.nahbrc.org.
• Local hazardous waste resources include:
• The Washington State Department of Ecology, Northwest Regional Office, Hazardous Waste Specialists,
425-649-7040.
Also see the General Resources at the beginning of this Section for information on erosion control.

2-45 When construction is complete, leave no disturbed areas uncovered or


unstabilized
2 POINTS

All disturbed areas should be treated in some way with landscaping, site features, or erosion control devices.

Bare soil will erode due to wind and water. Seed, replant, or cover exposed soils with compost, mulch, vegetation,
and/or matting as soon as practical. Use wildflower seeds appropriate for this region for color and interest, such as
along driveways. .

2-46 Do not bury construction waste


1 POINT

Pursuant to state regulations, all solid waste, including construction waste generated by contractors, must be
disposed of at a proper disposal site permitted by the jurisdictional health department. Demolition waste can be
disposed of at a permitted inert/demolition landfill or other landfill that accepts this material. Call the Department
of Ecology’s regional offices for information on permitted landfills in your area. The Built Green Program
promotes waste reduction and recycling. (Section Five: Materials Efficiency, includes more information on ways to
reduce your waste and disposal costs.)

• Information on fire protection


Gifts could include:

• Non- or low-toxic cleaning supplies, such as environmentally friendly laundry or dish detergent, or paper
products with recycled-content
• Environmentally friendly furnace filter(s)
• Native species flower seeds
• Environmentally friendly gardening supplies

2-47 Establish and maintain a single stabilized construction entrance (quarry spall,
crushed rock or concrete)
1 POINT

Since construction traffic can help contaminate storm and surface water, establish a single stabilized entrance to
minimize potential impact. Properly constructed, a single entrance can reduce compaction on site (see Action

32
item 2-19, Avoid Soil Compaction by Limiting Heavy Equipment Use to Building Footprint and Construction
Entrances).

Figure 2-3 Stabilized Construction Entrance

Figure 2-3 Stabilized Construction Entrance illustrates examples of a stabilized construction entrance. Use crushed
rock, asphalt, or cement. Pave driveways to the intersecting road edge before installing construction entrance
(prevents damage to roadway). Install a driveway culvert if a roadside ditch is present. Construct entrance on a
firm, compacted subgrade (reduces maintenance). Place geotextile or ground wood chips under gravel to prevent
sediment from pumping up into the rock pad. Grade the entrance so that runoff drains back onto construction
site. Direct water draining from tire wash or any other related runoff to sediment trap or pond.

Carry out periodic inspections and maintenance including washing, top-dressing with additional stone, reworking,
and compaction. Plan for periodic street cleaning to remove any sediment that may have been tracked out.
Sediment should be removed by shoveling or sweeping and transported to a suitable disposal area where it will
not be re-eroded. Consider installing fencing as necessary to restrict construction traffic to stabilized entrance.

2-48 Preserve and cover topsoil on site for reuse


3 POINTS

Stockpile topsoil removed during grading for use during final landscaping. The top layer of soil is the most
valuable, and should be separated and used again on site as a top layer in grading planting areas. However, bare
soil will erode due to wind and water. Protect stockpiled topsoil from erosion by covering with mulch (preferred)
or plastic (less preferred because it can cause rapid runoff) until ready for reuse. Surround all stockpiles with a silt
fence or compost berm and inspect regularly for proper coverage or sign of erosion, especially after a large storm.
Screen soil to remove debris before redistributing for final grading and landscaping.

Native topsoil is best adapted to the site. Limit importing topsoil as much as possible. “New” topsoil is not
adapted to your site and thus cannot offer the same nutrient structure, disease resistance, or hydrologic
capabilities.

33
If you do have extra topsoil remaining after final grading and landscaping, consider mixing it with non-organic and
inert material to be used as fill (make sure fill materials are clean). Also you can use it in the construction of slopes,
or sell it to homeowners, landscapers, or other businesses for reuse.

Absolutely no topsoil should be disposed of in low areas or wetlands. Disposing of topsoil in lowlands or wetlands
threatens water quality and quantity and endangers wildlife habitat.

2-49 Wash out concrete trucks into storage containers, slab, or subbase areas.
1 POINT

Over the life of a project one to three yards of concrete slurry and lime can be generated from washing out
concrete trucks. Cementitious runoff can contaminate the site, harm local waterways, aquatic habitat and fish
species, reduce conveyance capacity of surrounding stormwater systems, plug infiltration facilities, and
contaminate treatment facilities.

The Stormwater Management Manual requires that Best Management Practices shall be used to prevent or treat
contamination of stormwater runoff by pH modifying sources. BMPs include allowing concrete truck chutes,
pumps, and internals, along with hand tools, to be washed out only into formed area awaiting install of concrete
or asphalt. For equipment that cannot be easily moved or driveway wash-down, the wash water cannot directly
drain to natural or constructed stormwater conveyances. Wash water and leftover product can also be contained
in a lined container and removed off site for proper disposal such that it does not violate groundwater or surface
water quality standards.

Code allows for self-installed concrete washouts on the site. However, these self-installed structures are much less
reliable and are prone to leaks. Prefabricated washout containers that are delivered to the site resist damage and
protect against spills and leaks.

Resources
For general information about washing out work vehicles see:

• “Vehicle and Equipment Wash water Discharges” (excerpted from Best Management Practices Manual)
(Publication No. WQ-R-95-56). Washington State Department of Ecology. 360-407-7472 or
www.wa.gov/ecology/pubs.html.
• “Concrete Washout” by National Pollutant Discharge Elimination System (NPDES).
Available online at
http://cfpub.epa.gov/npdes/stormwater/menuofbmps/index.cfm?action=browse&Rbutton=detail&bmp=1
17.

2-50 Establish and post clean up procedures for spills to prevent illegal discharges
1 POINT

Requirements for cleaning spills or releases vary with the material. You should become familiar with cleanup
procedures for the materials you use regularly. Included in your Clean-up Procedures should be components of a
safety program, which considers the range of potential spills and establishes appropriate emergency actions. See
the Resources Section for references designed to help you establish clean-up procedures and for contact
information for large spills.

Make sure everyone, especially subcontractors, is aware of your procedures by posting them prominently in a
central location and referring to them regularly during safety meetings.

Resources
See Resources, Hazardous Waste, above. Especially, see:

34
• Pollution Prevention Users Guide: For use with Pollution Prevention Plan
https://fortress.wa.gov/ecy/publications/publications/0204023.pdf, order by telephone 360-407-7472,
online at https://fortress.wa.gov/ecy/publications/UIPages/Home.aspx or e-mail ecypub@ecy.wa.gov.
• Step by Step: Fact Sheets for Hazardous Waste Generators (Publication #91-012). See Resources,
Hazardous Waste, above.
Also, ask for:

• Reporting Releases of Hazardous Substances (Publication Number R-TC-94-133). Washington State


Department of Ecology. 360-407-7472 or www.wa.gov/ecology/pubs.html.

2-51 Reduce hazardous waste through good jobsite housekeeping


1 POINT

Eliminating sources of hazardous waste by using good housekeeping and non-hazardous alternatives is the best
way to curb your hazardous waste generation, reduce costs associated with disposal, improves air quality, and
avoid potential liability. If you are not able to substitute less or non-toxic alternatives and still need to purchase a
hazardous product, use care in purchasing and managing the product. Here are some ideas:

• Avoid overstocking hazardous materials. Dated materials become hazardous waste.


• Adopt a “first-in, first-out” policy to prevent raw materials from becoming obsolete.
• Label hazardous waste containers properly to avoid mixing incompatible wastes or contaminating clean
materials.
• Keep excess material in original containers.
• Keep containers closed to prevent evaporation into the air.
• Control access to storage areas and routinely inspect containers.
• Inspect containers upon receiving. Reject leaking or damaged containers. These can lead to a hazardous
materials spill.
• Promptly clean up spills and know response procedures ahead of time.
• Maintain vehicles and equipment at a central location, preferably in a garage or maintenance facility. Keep
vehicles tuned and leak-free. Fluids removed from vehicles should be recycled or disposed of at an
approved facility.

Resources
See Resources, Hazardous Waste and Action item 2-50, Establish and Post Cleanup Procedures for Spills to
Prevent Illegal Discharges.

Software estimating/take off systems are available to help accurately estimate the quantity of materials you will
need for a specific job. Trade magazines often review these programs and provide cost and contact information.

2-52 Produce no hazardous waste


3 POINTS

2-53 Construct tire wash, establish and post clean up protocol for tire wash
3 POINTS

For on-site tire wash, make sure the area is:

35
• Well marked as a wash area.
• No larger than the largest vehicle.
• Posted with a sign that forbids washing with solvents or changing oil and indicates nearest oil recycling
area.
In addition, pave and drain the area to an oil-water separator if it is connected to the sanitary sewer, or direct tire
wash water to other sediment trap or pond. Provide temporary gravel base on site to keep vehicles clean.

Post tire wash protocol for all trades or field labor using vehicles on site. Procedures may include:

• Washing vehicles off-site. Take them to an appropriate location (in other words, a car wash or back to your
central site).
• If taking the vehicle off-site is impractical or counterproductive, perform all washing in a designated area.
• Require biodegradable detergents. Detergents or cleaners containing phosphate are prohibited. Minimize
quantity of soap, detergents, or other chemicals used.

Resources
For information about washing out work vehicles in general see:

• “Vehicle and Equipment Wash water Discharges” (excerpted from Best Management Practices Manual)
(Publication No. WQ-R-95-56). Washington State Department of Ecology. 360-407-7472 or
www.wa.gov/ecology/pubs.html.
For information about washing out work vehicles in general see:

• “Vehicle and Equipment Wash water Discharges” (excerpted from Best Management Practices Manual)
(Publication No. WQ-R-95-56). Washington State Department of Ecology. 360-407-7472 or
www.wa.gov/ecology/pubs.html.

2-54 Use slow-release organic fertilizers to establish vegetation


2 POINTS

Studies have shown that 62% of the phosphorus entering Lake Sammamish is coming from single-home
residential areas. The primary source for this contaminant is fertilizers and soil wash-off. Excess nutrients promote
algae blooms, which in turn threatens fish and aquatic life. Moderate fertilization with natural or natural/synthetic
slow-release combination fertilizers will help build soil nutrient reserves and biodiversity without contaminating
waterways.

2-55 Use less-toxic form releasers


2 POINTS

Forms are commonly coated with fuel oil to prevent the concrete from sticking to the form. Runoff, incidental
drips, and spills contaminate soils and may enter storm drains thereby contaminating surface water. Use less toxic
form releasers or strategies, such as “kick-hard,” vegetable oil spray, or waxing or painting the forms prior to use.

Resources
• “Kick hard.” Don’t use form oil at all and clean forms promptly after use. This works on smaller pours.
• Use vegetable oil sprays (mix vegetable oil with water and apply using pump can).
• Wax or paint the forms.

36
• Cast Off-W, ChemRex, Inc. (makers of Sonneborn Building Products), Shakopee, MN. 800-433-9517.
Contains a significantly lower level of petroleum distillate than traditional products.
• BioForm, Leahy-Wolf Co. 847-455-5710. Product is non-toxic, biodegradable, and non-staining.
New products that eliminate the need for wood forms include:

• Steel forms.
• Formadrain, CertainTeed Corporation, Pipe and Plastics Group, Valley Forge, PA. 610-341-6950 or
www.certainteed.com. Manufactured out of PVC, it serves as the form, but stays in place. The product is
perforated and is designed to drain the foundation or vent radon as well.
• Soy Form Away, SoySolv Industrial Solvents and Cleaners, Tiffin, OH. 800-231-4274, 419-992-4595, or
www.soysolv.com. Water-based, non-toxic, soap and water cleanup and made from a renewable resource.
Available through D.J. Stevens Distributing, San Diego, CA. 614-424-3220.

2-56 Use non-toxic outdoor materials for landscaping (plastic, non-treated wood)
1 POINT

Using non-- or low-toxic materials in the landscape helps preserve soil and water quality. Examples include
low-toxic wood preservatives, naturally rot-resistant woods, and plastic lumber (preferably with recycled
content). See Section Five: Materials Efficiency Action items 5-117, Use Reclaimed or Salvaged Material for
Landscaping Walls and 5-119, Use 100% recycled-content plastic or wood polymer lumber for decks and porches, or
third party certified wood products .

Resources
For general and product information for low toxic landscape materials and methods, consult:

• Resource Guide to Sustainable Landscapes and Gardens, Wesley Groesbeck and Jan Striefel, 1995.
Environmental Resources Inc., Salt Lake City, UT.
Unlike wood, recycled-content plastic lumber and landscape edging does not need to be treated with toxic
finishes for outdoor use. It also has the benefit of being resource efficient. Your local supplier may carry a brand of
recycled-content plastic lumber, but if not, some locally distributed products include:

• ChoiceDek, manufactured by A.E.R.T. (Advanced Environmental Recycling Technologies), Akron, OH.


800-951-5117 or www.choicedek.com.
• SmartDeck, Eaglebrook plastic lumber, Chicago, IL. 312-491-2500 or www.eaglebrook.com. Distributed by
Northwest Recreation, Tualatin, OR. 800-448-4858.
• Enviroedge landscape edging (plastic bender board and stakes), Enviroedge Products Co., Huntington
Beach, CA. 800-549-3343. Available at Home Depot stores.
• Rebound, Recycled Plastics Marketing (RPM), Redmond, WA. 800-867-3201 or 425-867-3200.
• RESCO plastic lumber, by RESCO Plastics, Coos Bay, OR. 541-269-5485 or www.rescoplastics.com.
Available from T. R. Strong Building Systems in Olympia. 360-705-2868 or www.baubuilder.com.
• TREX Easy Care Decking, Winchester, VA. 800-BUY-TREX or www.trex.com. Many local suppliers.
• Vanco Associates, Edmonds, WA. 253-826-9659. Distributes recycled-content plastic landscaping timbers.
See also Section Five Resources: Materials Efficiency for sustainable lumber Action items.

2-57 Do not clear or grade during wet weather periods


5 POINTS

37
Phase construction and plan ahead to avoid clearing and grading wet weather periods, primarily November
through March. This is particularly important for soils that are easily eroded. To find out if the soils at your site
qualify as “easily eroded,” go to the Soil Conservation Surveys (SCS) at your local library. Each County has these
surveys that classify soil types throughout the County. Locate your site on the surveys to determine your site’s soil
type. The surveys include a discussion of the engineering properties including erosion potential, classified as “light
to moderate” or “severe.”

Consult your code official for more information. Also consult your local municipality to determine the specific
regulations for wet weather clearing and grading that apply for your site.

2-58 Do not use zinc galvanized ridge caps, copper flashing, or copper wires for moss
prevention
2 POINTS

Zinc galvanized ridge caps, copper flashing, copper wires, and shingles impregnated with copper or zinc granules
are sometimes installed on roofs to discourage moss and other growth. However, they are of environmental
concern because the zinc and copper will leach from these products into stormwater. Once a part of the water
cycle, they can accumulate to toxic levels in the food chain. See Action item 2-73, Educate Homeowners about Fish-
Friendly Algae/ Moss Control.

Moss and Algae can most effectively be removed using a stiff corn broom on a hot summer day. Avoid the use of
pressure washers to remove moss and algae, since these can damage shakes and shingles, reducing their
effectiveness and service life.

Resources
See Action item 6-12, Educate Owner/Tenant about Fish-Friendly Moss Control.

Heat Island Mitigation

2-59 Use light-colored hardscaping: Horizontal hardscaping materials are installed


with a Solar Reflectance Index of 29 or greater for minimum 50% surface area
2 POINTS

Heat islands are created when urban surfaces, such as hardscapes, absorb solar radiation. Shading the pavement
cools the air surrounding it before that air reaches a building’s walls and windows. Landscape features such as
mature trees or hedge rows, exterior elements such as overhangs or vertical fins, and horizontal reflecting
surfaces called light shelves are all strategies that can help reflect solar radiation.

Planting trees and vegetation is a simple and effective way to reduce heat islands. Shade trees and other foliage
can lower air temperature by up to 9 degrees. Widespread planting in a city can decrease local surface and air
temperatures. Strategic planting around buildings directly cools the interior of buildings and buildings, decreasing
air conditioning costs and peak energy demand.

Trees and vegetation cool the air by providing shade and through evapotranspiration (the evaporation of water
from leaves). The U.S. Department of Agriculture Forest Service estimates that every 1% increase in canopy cover
results in maximum mid-day air temperature reductions of 0.07° to 0.36° F (0.04° to 0.2°C).

Since the goal is to provide shading for hardscapes, building features, such as overhangs and light shelves also
help to reflect solar radiation and can be incorporated into the overall design to serve many beneficial functions
for the building and the surrounding site.

For information on overhangs, see Action items 4-48 and 4-49.


38
High Albedo, light-colored, and cool roofs are all terms used to describe an alternative roofing strategy that
lowers the absorption of solar energy, reduces surface temperatures, and decreases the heat transfer into a
building. Typically, they are white and are made of either metal, single ply membrane, or elastomeric coating over
a conventional roof.

Dark materials absorb more heat from the sun. Roads and parking lots paved with black asphalt concrete and
other dark materials can become up to 70°F hotter than the most reflective white surfaces. The energy of the
sunlight is converted into thermal energy and pavements get hot, heating the air around them and contributing to
the heat island effect. Dark colored roofs also heat the air around the building, contributing to the heat island
effect. The efficacy of high albedo roofs is dependent on climate situations. In our region, unless the building is
planning an air conditioning system, it may not be advantageous to utilize this strategy. This is due to the extra
cost of the roofing materials, the potential for degradation of high albedo coatings, and the potential to increase
costs for heating. However, if the building intends to supply air conditioning, this strategy can be effective since
these roofs minimize the absorption of summer heat, thereby reducing air conditioning costs. These roofs reduce
air conditioning cost in two ways; first, by reflecting solar gain, then by providing cooler roof intake air.

Cool paving materials minimize the absorption of solar heat and the subsequent transfer of this heat to the
surroundings. There are two types of cool paving materials: lighter-colored materials and porous materials.

• Lighter-colored materials have higher solar reflectance, so they absorb less of the sun's energy and stay
cooler. Permeable, or porous, pavements allow water to filter into the ground, keeping the pavement cool
when moist (this pavement alternative also serves as a stormwater management technique). Permeable
pavements can be constructed from a number of materials including concrete, asphalt, and plastic lattice
structures filled with soil, gravel, and grass, see Action item 2-44, Use pervious materials for driveways,
parking areas, walkways, and patios.
• Pervious pavements are less able to absorb and store heat than conventional pavements. The lower
density of the material (15 - 25% void spaces) reduces heat storage capacity. The open void structure in the
pervious pavement allows cooler earth temperatures from below to cool the pavement. These factors
allow pervious pavement systems to approach natural ground cover in heat absorbing and storage
capacity. In addition, the lighter colors of some pervious pavement systems further reduce the heat
absorbing capacity of the pavement.

WATER PROTECTION
Outdoor Conservation
Although outdoor water use varies widely from site to site, on average it accounts for about 50% of residential
water use. However, proper selection of plants and turf, landscape arrangement, irrigation equipment, use of soil
amendments, and irrigation scheduling can dramatically reduce outdoor water use. Along with indoor
conservation measures, outdoor water conserving features can help reduce daily water use from an average of
80 gallons per day (gpd) to 50 gpd.

2-60 Mulch landscape beds with 2 inches of organic mulch


1 POINT

If the new landscape isn’t already densely planted, mulching is the next best solution to reduce the number of
weeds and makes weed removal easier (which in turn, helps minimize herbicide use). Mulching provides soil
nutrients, increases the capacity of the soil to retain moisture, moderates soil temperature, and limits soil erosion.

Non-woody mulches, compost, cut grass clippings, or leaves are best for annuals. Woody mulches, wood chips or
bark, work best with perennial shrubs and trees. However, limit the use of bark mulch as much as possible, and
never use in areas that drain directly into storm sewers or open water. Bark produces a toxic leachate that can end
up in water supplies.

2-61 Limit use of turf grass, or use no turf grass

39
3-12 POINTS

3 POINTS FOR EVERY 25% OF LANDSCAPED AREA THAT DOES NOT INCLUDE TURF GRASS.

12 POINTS FOR NO TURF GRASS

Design turf areas where they will be functional and well adapted to the site. Specifically, place turf in areas
expected to be used for walking or playing. Lawns work well in sun to light shade, with well-drained soils and on
level to slightly sloped areas. Don’t plant lawns in heavy shade or in areas with saturated soils or heavy slopes.
Always keep turf away from the water’s edge because of the increased likelihood of chemical contamination,
because it reduces habitat and shading for wildlife, and because of the possible increase in erosion potential.
Finally, design the lawn in a shape that can be efficiently watered, in other words, it matches the irrigation system
design. For instance, use an oval shape to accommodate sprinkler sprays or pop-up irrigation sprays.

Although turf grass is a traditional component of residential landscaping, it is not necessary for a beautiful and
luxurious landscape. In fact, a landscape, which uses existing vegetation along with well-constructed new
plantings, can offer a beautiful, low-maintenance alternative to the “traditional” fare.

Constructed landscapes that mimic ecological habitat models can decrease life cycle maintenance costs, enhance
wildlife survival, and blend edges of adjoining existing vegetation. To mimic ecological habitat models, emulate
natural succession by planting larger deciduous trees with smaller conifers to gradually develop canopy.
Deciduous trees generally perform better in south-facing areas, while conifers are better suited near streams or
on the north side of the plot.

Use native plants in the constructed landscape. They:

• Are diverse in color, form, and texture offering a wide variety to fit any design.
• Are adapted to our climate – rainy wet winters and dry summers. After initial one to two seasons of
irrigation, many native plant species become established and require little to no irrigation.
• Are adapted to our naturally occurring low levels of nutrients.
• Are resistant to local insects and diseases, which allow for minimizing fertilizer and pesticide use.
• Provide habitat for local wildlife.

2-62 Use drought-tolerant grass type


2 POINTS

When planting a new lawn, select a grass mix that is suitable for the sun conditions and the lawn’s intended use,
and grows slowly, requiring less frequent mowing. Use locally adapted rye-fescue seed blends. Be aware that tall
and other fescue grasses can be drought-tolerant if given a deep soil culture for their long roots – they need more
water if planted in shallow soil. Mixes containing clover, bentgrass, yarrow, chamomile, and English daises are
another option where an informal-looking lawn fits the landscape. These mixes are extremely drought-tolerant
and offer a variety from traditional lawns.

Regardless of the type of grass you choose, always plant densely. Thick, dense, and thatchy well-established
lawns absorb and infiltrate rainwater better than thinly planted plots. (Soil conditions can significantly affect lawn
establishment. See also Action item 2-34, Amend disturbed soil with compost or suitable soil amendments to a
minimum depth of 10" to restore soil environmental functions.)

2-63 Landscape with plants appropriate for site topography and soil types,
emphasizing use of native plants with low watering requirements (drought-
tolerant)

40
2 POINTS

In the summer, up to 50% of the water used by municipal systems is for outdoor irrigation. The increased demand
in summer coincides with a drop in reservoir and stream levels when precipitation dramatically decreases, putting
tremendous pressure on local water supplies.

Examples of water saving landscaping techniques you can include:

• Use established vegetation (see Action item 2-21, Preserve Existing Native Vegetation as Landscaping, for
more information)
• Limit turf areas, choose appropriate turf types and plant in suitable areas (see Action item 2-61, Limit use
of turf grass, or use no turf grass)
• Cluster plants with similar water requirements (“water-use” zones)
• Plant native species that will adapt well to the site
• Plant species from other geographic areas with similar climates
• Plant certain species from Mediterranean climates (check with your local nursery for ideas).
The Pacific Northwest has hundreds of attractive plants that require very little water once they are established.
Ask your local nursery or landscaping contractor for information about the water efficient trees, shrubs,
perennials, and ground covers they supply. Keep in mind that some low water use plants may have certain needs,
such as shade, which when not met can lead to increased water use.

Constructed landscapes that mimic ecological habitat models can decrease life cycle maintenance costs, enhance
wildlife survival, and blend edges of adjoining existing vegetation. To mimic ecological habitat models, emulate
natural succession by planting larger deciduous trees with smaller conifers to gradually develop canopy.
Deciduous trees generally perform better in south-facing areas, while conifers are better suited near streams or
on the north side of the plot.

Use native plants in the constructed landscape that are:

• Diverse in color, form, and texture offering a wide variety to fit any design
• Adapted to our climate – cold, snowy winters and hot, dry summers. After initial one to two seasons of
irrigation, many native plant species become established and require little to no irrigation
• Adapted to naturally occurring low levels of nutrients
• Resistant to local insects and diseases, which allow for minimizing fertilizer and pesticide use
• Native to provide habitat for local wildlife.
Landscapes can also be Xeriscaped, which means that once established, the landscape will survive without any
watering needs. Xeriscaping has become popular in dry areas over recent years and increasingly more resources
are available on it. See Part II, Resources for more info on Xeriscape options in our area.

2-64 Plants with similar watering needs are grouped (hydrozoning)


5 POINTS

Although turf grass is a traditional component of residential landscaping, it is not necessary for a beautiful and
luxurious landscape. In fact, a landscape, which uses existing vegetation along with well-constructed new
plantings, can offer a beautiful, low-maintenance alternative to the “traditional” fare.

Constructed landscapes that mimic ecological habitat models can decrease life cycle maintenance costs, enhance
wildlife survival, and blend edges of adjoining existing vegetation. To mimic ecological habitat models, emulate
natural succession by planting larger deciduous trees with smaller conifers to gradually develop canopy.

41
Deciduous trees generally perform better in south-facing areas, while conifers are better suited near streams or
on the north side of the plot.

Use native plants in the constructed landscape. They:

• Are diverse in color, form, and texture offering a wide variety to fit any design
• Are adapted to our climate – rainy wet winters and dry summers. After initial one to two seasons of
irrigation, many native plant species become established and require little to no irrigation.
• Are adapted to our naturally occurring low levels of nutrients
• Are resistant to local insects and diseases, which allow for minimizing fertilizer and pesticide use.
• Provide habitat for local wildlife
In the summer, up to 50% of the water used by municipal systems is for outdoor irrigation. The increased demand
in summer comes at the same time reservoir and stream levels drop and precipitation dramatically decreases,
putting tremendous pressure on local water supplies.

Examples of landscaping techniques you can use that will result in low water use include:

• Use established vegetation


• Limit turf areas, choose appropriate turf types and plant in suitable areas
• Cluster plants with similar water needs (―water-use zones)
• Plant native species that will adapt well to the site
• Plant species from other geographic areas with similar climates
• Plant certain species from Mediterranean climates (check with your local nursery for ideas)
The Northwest has hundreds of beautiful plants that require very little water once they are established. Ask your
local nursery or landscaping contractor for information about the water efficient trees, shrubs, perennials, and
ground covers they supply. Keep in mind that some low water use plants may have certain needs, such as shade,
which when not met can lead to increased water use.

Resources
• Washington Native Plant Society, http://www.wnps.org/landscaping/eastshrubs.html

2-65 Pre-plumb for greywater reuse for irrigation


4 POINTS

Greywater is all wastewater generated in the house except from toilet flushing. Sometimes referred to as
“reclaimed” or “recycled” water, this includes wastewater from laundries, showers, and sinks. Greywater can be
collected and stored for reuse as a nutrient-rich irrigation source, which conserves water. To use greywater, a dual
plumbing system must be installed to separate it from blackwater, which is wastewater generated from toilet
flushing.

Greywater systems are currently treated as an “exception” to the code. Systems are approved, on a case-by-case
basis as “experimental” systems, requiring compliance with stringent local and state regulations. If approved,
greywater irrigation systems are generally required to be subsurface, although some local jurisdictions permit
aboveground irrigation. Factors affecting the approval and use of greywater irrigation systems include soil depth
and characteristics as well as drainage and flooding patterns. Other guidelines include setbacks for greywater
irrigation lines from property or potable water line.

Note: If you choose to plumb for greywater irrigation, you should also consider providing plumbing to use
greywater for toilet flushing (see Action item 2-82, Bonus Points:Stub-in plumbing to use greywater or rainwater for
indoor reuse.)
42
Figure 2-4 Rainwater/Greywater System

Resources
• “Some chemicals in greywater can be harmful to plants (For information about suitable plants for
greywater, please see Greywater Plant Choices at:
http://www.doh.wa.gov/ehp/ts/ww/greywater/greywater-5.htm#plantchoices.” (excerpted from Water
Conservation, Using Greywater Fact Sheet, Washington State Department of Health,
http://www.doh.wa.gov/ehp/ts/WW/GreywaterFact.PDF.)
Note: If you choose to plumb for greywater irrigation, you should also consider providing plumbing to use
greywater for toilet flushing (see Action item 2-82, Bonus Points:Stub-in plumbing to use greywater or rainwater
for indoor reuse.)

• Recommended Standards and Guidance For Water Conserving On-site Wastewater Treatment Systems,
Appendix D, Greywater Reuse,
http://www.ecy.wa.gov/programs/wq/tmdl/spokaneriver/dissolved_oxygen/docs/WaterConservSystems-
2000.pdf

2-66 Install greywater system for irrigation


5 POINTS

Recycled water includes both rainwater and greywater.


43
See Action item 2-65, Pre-plumb for greywater reuse for irrigation for discussion of greywater and related
requirements. In cases where greywater for irrigation is acceptable, plumbing for greywater would be hooked up
to the irrigation system. The irrigation system can be supplied using the tank(s) and a small-scale pressurized
pump system.

In cases where you would be using collected rainwater (on a per site basis, a more cost-effective approach), hook
up the irrigation system to the rooftop cistern (see Action item 2-68, Install Rainwater Collection System (Cistern)
for Reuse). These systems can provide significant quantities of irrigation water. Whether a rooftop cistern will be
sufficient to meet all of the irrigation demands during the dry season will be dependent upon the irrigation
requirements of the landscape and the system’s storage capacity.

2-67 Install landscaping that requires no potable water for irrigation whatsoever after
initial establishment period (approx. 1 yr), excluding food production
10 POINTS

The goal of this credit is to select a landscape plan that includes drought-tolerant plantings, smart plant
placement, and that no potable water will be used for irrigation after the initial establishment period of about one
year.

Select plants that are native to the area or suitable for our climate and rainfall characteristics. You should amend
soil with compost to help establish good soil conditions to establish new plants; proper placement of individual
plants in the landscape can reduce supplemental watering needs. Add hardscape and mulch or bark areas as
landscape features that do not require watering.

For initial establishment irrigation consider using greywater – non-potable wastewater from the house from
bathtubs, showers, bathroom sinks, washing machines, dishwashers and kitchen sinks, any water source in the
home except for toilets. This wastewater is collected and filtered of household contaminants such as bacteria,
bleach, high pH wastewater, nitrates, oil and grease, food and hair, etc. Check with the county health agency for a
wastewater treatment permit and to confirm local code requirements, and system design suggestions. Consider
the source and characteristics of the greywater, the physical characteristics of the site, and how the greywater will
be used on site for irrigation. All greywater systems must be below or sub-surface, no sprinkler systems area
allowed.

Be prepared, or prepare the homeowner to remove the temporary system after the initial plant establishment
period. A carefully selected and planted landscape designed for specific site characteristics should be established
and no longer requires supplemental watering after about one year.

Resources
See General Resources

• Saving Water Partnership, Smart Watering, part of the Natural Lawn & Garden series, 2004, available at
http://www.savingwater.org/outside_watering.htm or 206-633-0224.

2-68 Install rainwater collection system (cistern) for reuse


1 POINT PER 100 GALLONS OF STORAGE CAPACITY
EXAMPLE: 500 GALLONS = 5 POINTS
10 POINTS MAXIMUM

Rainwater collected from the roof is a free source of landscape irrigation water. Rainwater can also be harvested
from soil surfaces and outdoor paved surfaces. Let the homeowner know that rainwater supply is not intended for
potable use (in other words, is not for drinking). Rainwater collection for potable water use can be done, but

44
requires case-by-case approval and compliance with stringent local and state health regulations. Check with your
local municipality for rainwater collection regulations.

A rooftop rainwater collection system consists of a suitable roof and gutter system, a storage tank(s), and a simple
filtration system. The irrigation system can be supplied using the tank(s) and a small-scale pressurized pump
system. These systems can provide significant quantities of irrigation water. Whether a rooftop cistern will be
sufficient to meet all of the irrigation demands during the dry season will depend on landscape irrigation
requirements and the system’s storage capacity.

Individual cisterns can be located beneath each downspout, or the desired storage volume can be provided in one
large, common cistern that collects rainwater from several sources. Pre-manufactured residential-use cisterns
come in sizes ranging from 100 to 1,400 gallons. Cisterns should be located for easy maintenance or replacement.

For collecting rainwater from roof areas:

• Use appropriate roofing materials such as metal, tile, or fiber cement. Lead-containing materials, such as
flashing, should not be used in catchment roofs. Likewise, ensure that no zinc, moss prevention measure
such as galvanized ridge caps, copper flashing, or copper wires are used. Asphalt composition roofs should
not be used for collecting water for watering any food producing plants.
• Construct cistern or tank storage sized for the rainfall amount and roof size, with appropriate overflow
devices. Cisterns can be made of concrete, ferro-cement, stone, or prefabricated metal, plastic, or
fiberglass. Use only watertight, opaque materials and provide a cover.
• Provide an overflow route to direct excess flows away from building and in such a manner as to avoid
impact to downstream properties.
• Install gutters and downspouts sized for the roof and rainfall intensity.
• Install screening devices or roof washers to filter out leaves, debris, and sediment that can clog the
system.
For collecting and harvesting water from the soil surface and outdoor paved surfaces:

• Use open conveyances such as grass or gravel swales to direct and deliver harvested water to storage
areas, such as small ponds, for reuse as irrigation water.
• Provide a pressurization system to deliver irrigation water.
• Incorporate aquatic plants to maintain storage pond’s ecological balance.
See Action item 2-65, Pre-plumb for greywater reuse for irrigation for discussion of greywater and related
requirements. In cases where greywater for irrigation is acceptable, plumbing for greywater would be hooked up
to the irrigation system. The irrigation system can be supplied using the tank(s) and a small-scale pressurized
pump system.

In cases where you would be using collected rainwater (on a per site basis, a more cost-effective approach), hook
up the irrigation system to the rooftop cistern. These systems can provide significant quantities of irrigation
water. Whether a rooftop cistern will be sufficient to meet all of the irrigation demands during the dry season will
be dependent upon the irrigation requirements of the landscape and the system’s storage capacity

2-69 Irrigation system is designed by a professional in accordance with EPA


WaterSense requirements (or equivalent) and installed in accordance with EPA
WaterSense Program or equivalent
3 POINTS

Designed by a professional in accordance with EPA WaterSense requirements, or equivalent

Installed in accordance with EPA WaterSense program, or equivalent

45
2-70 Evapotranspiration- (ET-) based irrigation controller with a rain sensor
4 POINTS

2-71 Soil moisture sensor based irrigation controller


4 POINTS

Each irrigation zone has a solenoid valve on it that is controlled via wire by an irrigation controller. The irrigation
controller is either a mechanical or electrical device that signals a zone to turn on at a specific time and keeps it on
for a specified amount of time. "Smart Controller" is a recent term used to describe a controller that is capable of
adjusting the watering time by itself in response to current environmental conditions. The smart controller
determines current conditions by means of historic weather data for the local area, a soil moisture sensor (water
potential or water content), weather station, or a combination of these.

2-72 Install a leak detection system with excess water flow shutoff
2 POINTS

2-73 An integrated pest management plan to minimize chemical use of pesticides and
fertilizers is established
4 POINTS

The National Information System of the Regional Integrated Pest Management Centers describes the pest
management plan as “a pest-by-pest” approach to identifying the current management practices (chemical and
non-chemical) and those under development. Plans also state priorities for research, regulatory activity, and
education/training programs needed for transition to alternative pest management practices.

Indoor Conservation

2-74 Plumbing system with all plumbing fixture fittings (faucets & showerheads)
located such that the volume of the water contained in each pipe run between
the water heater and fixture fitting is a maximum of 6 cups (1.42 liters) (86.63
cubic inches) (0.38 gallons)
8 POINTS

Small diameter flexible pipes are run from a manifold with branched outlets located near the water heater directly
to the fixtures, thereby reducing the volume of water in the individual pipe. Use 3/8 piping for sinks and ½ piping
for other fixtures.

Use central core plumbing which means locating the water heater to within 15 feet of all hot water fixtures,
including bathrooms, kitchen and laundry.

2-75 For bathroom faucets, select fixtures with less than 1.5 GPM
2 POINTS

EPAct92 limits the flow rate of residential kitchen and lavatory (bathroom) faucets to 2.5 gpm (9.5 lpm) at 80 psi,
or 2.2 gpm (8.3 lpm) at 60 psi—although some faucets today achieve the federally mandated flow with either
aerators or flow restrictors that can be removed, allowing the flow to be significantly increased. EPA’s WaterSense
has adopted a more aggressive maximum flow rate of 1.5 gpm (5.7 lpm) at 60 psi for residential lavatory faucets;
46
because of the need to fill kitchen pots with water, however, a WaterSense standard for kitchen faucets has not
been adopted. In kitchens, flow controllability tends to be a more significant water-saving feature. While sensors
that turn on the flow when a user’s hands are properly positioned—most common in commercial buildings but
making their way into homes—might seem like a water-saving feature, studies have shown that they often
increase water use because they turn on unnecessarily or stay on longer than needed.

Simple, inexpensive aerators can adapt any modern kitchen or lavatory faucet into a water-efficient unit—with
flow rates as low as 0.5 gpm (2 lpm). The lower the flow rate, however, the longer it takes hot water to reach the
user). A perception of greater flow can be achieved by aerating the water stream or by creating a laminar flow
(essentially a hollow cylinder of water that appears to be solid). Significant savings can be achieved with faucets—
and especially kitchen faucets—by installing a foot- or knee-operated control so that users can turn the water on
and off without using their hands (and while retaining the desired temperature mix). A less expensive option is a
simple lever control on the faucet itself that allows the user to temporarily reduce the flow (though usually not
turn it all the way off) with a simple flick of the finger.

(Source: February 1, 2008 Feature “Water: Doing More with Less” from Environmental Building News)

Consumer performance complaints with reduced flow rates are most often associated with the “feel” of the water
coming from the faucet and clogging associated with equipment that reduces flow rate with small hole screening.
Faucets with flow rates less than 2.5 gpm that have the “feel” of higher flow and that are guaranteed against
clogging are now available. Remember that not all brands are created equal, so talk to your supplier. The added
cost of higher-performance, low-flow heads is minimal, generally less than $25 per house.

2-76 Self-closing valve, motion sensor, metering, or pedal-activated faucet is installed


to enable intermittent on/off operation
1-3 POINTS

1 POINT PER FAUCET, 3 POINTS MAXIMUM

Once more people experience the convenience and water savings of foot- and knee-operated controls for faucets,
these devices are likely to become more common—especially if less expensive models enter the market. We may
also see sensor-activated controls that actually save water. Finally, we may see regulations for faucets that
prevent them from being modified to increase the flow above the legal limit.

(Source: February 1, 2008 Feature “Water: Doing More with Less” from Environmental Building News)

2-77 For showers, install showerheads with less than 2.0 GPM
1 POINT

Showerheads, like toilets, are regulated by EPAct92, which established a limit of 2.5 gallons per minute (gpm; 9.5
liters per minute, or lpm) at 80 psi of water pressure. Because showers use hot water, reducing water use also
saves energy. Replacing an older showerhead, which may flow at 5 gpm (20 lpm) or more, with a unit that uses 2.0
gpm (8 lpm) or less can pay for itself through reduced water and energy use in just a few months. Some early low-
flow showerheads atomized the water into tiny, high-pressure droplets that did not wet the body effectively and
quickly cooled off through evaporation. Some showerheads today achieve the federally mandated flow with
restrictors that can be easily removed by a plumber or user, allowing the flow to be significantly increased—thus
circumventing the regulations. Another way people have circumvented requirements is by installing multiple
showerheads and body-wash nozzles in one shower system or by creating rain-like water sculptures that
manufacturers claim are not showers at all.

The best showerheads today have been designed for water efficiency from the ground up. Some models rely on
the Venturi effect to aerate droplets and create the feel of a forceful shower while using relatively little water—as
little as 1.5 gpm (5.7 lpm); a challenge here is to keep the aeration from making the droplets too small. Other
manufacturers have gone even further in showerhead redesign, creating a pulsed shower with large droplets.

47
EPA’s WaterSense is working on a standard for showerheads that will likely bring us WaterSense-labeled products
by the end of 2009 with a maximum flow of 2.0 gpm (8 lpm), or possibly lower. (The GreenSpec standard for
showerheads is 1.75 gpm [6.6 lpm].) Plumbing manufacturers are developing methods of measuring the wetting
performance and heat retention of showerheads, according to Koeller, and EPA could eventually incorporate such
performance attributes into WaterSense standards. Look for the multiple-showerhead loophole to be addressed
in some way in the next several years. Also, regulations may prevent showerheads from being modified to
increase flow above the legal limit.

(Source: February 1, 2008 Feature “Water: Doing More with Less” from Environmental Building News)

2-78 Install at least 1 kitchen faucet with less than 2.0 GPM
1 POINT

See Action item 2-75 above.

2-79 Select high-performance low-flush or dual-flush toilets (1.28 gpm)


1 POINT PER TOILET
4 POINTS MAXIMUM

Federal law mandates all new toilets use no more than 1.6 gallons per flush (gpf). Toilet flushing is the largest
single use of water (up to 40% of residential water use), and water savings from the new standard is significant
compared to the older models that used 3 to 5 gpf.

High-efficiency toilets today are available with gravity-flush, pressure-assist, and flushometer–valve mechanisms.
Pressure-assist toilets, which compress air at the top of the refill tank to increase the flush velocity, use as little as
0.8 gpf (3 lpf) and typically achieve excellent performance. Flushometer-valve toilets, which use direct water
pressure without a tank, are common in commercial buildings. Dual-flush toilets, pioneered by Caroma in
Australia, now dominate Australia and much of Europe. Introduced into North America by Caroma in 1999, most
dual-flush toilets use 1.6 gpf for solids and 0.8 to 1.1 gpf (3–4 lpf) for liquids and paper. Caroma recently introduced
a model with a full flush of 1.28 gpf (4.8 lpf) and a reduced flush of 0.8 gpf.

HETs may become standard nationwide. California has passed legislation that will mandate that all new toilets
sold or installed in the state after 2014 be HETs. According to Barbara Higgins, executive director of the Plumbing
Manufacturers Institute, the plumbing industry is lobbying to make this requirement the new federal standard—
with a clearly defined schedule that gives manufacturers time to modify their products.

(Source: February 1, 2008 Feature “Water: Doing More with Less” from Environmental Building News)

Resources
• How to Buy a Water-Saving Replacement Toilet, US Department of Energy, FEMP Available online at
www.eren.doe.gov/femp/procurement/pdfs/toilet.pdf. A publication of the Federal Emergency
Management Program, this two-page fact sheet is primarily for federal agencies, but provides good
general information for residential builders as well.
• For a recent report / survey on low flow toilets performance and cost comparison, see
terrylove.com/crtoilet.htm.
• Top performers in consumer and plumber surveys include models manufactured by Toto (Drake and
Ultramax series), Gerber, and Western, which can be purchased from plumbing contractors. Brands like
American Standard, Briggs, Crane, Eljer, Kohler, Mansfield, and Universal Rundle can be purchased from
both plumbing contractors and in many hardware stores.
One highly rated low flow toilet is:

48
• Gerber Ultra Flush toilet with the Sloan FLUSHMATE Flushometer Tank System, available from Love
Plumbing and Remodel, 18628 NE 25th St, Redmond, WA 98052, terrylove.com/toilet1.htm.

2-80 Install composting toilets


10 POINTS

Composting toilets convert human waste into nutrient-rich fertilizer for non-food plants rather than mixing the
waste with potable water and flushing it down the drain. The advantages of these toilets include dramatic
reductions in water use, reduced groundwater pollution or sewage treatment impacts, and a recycling of
nutrients. One toilet can accommodate up to five persons. The payback period is about 10 years.

Some composting chambers can be used with microflush toilets; however, most are non-flush units. If composting
toilets are used, greywater treatment and disposal must be addressed. Systems must meet local health
department regulations for alternative on-site sewage systems.

Resources
• Composting Toilet World, for general and product information, http://www.compostingtoilet.org/.
• Envirolet Composting Toilets by Sancor, available on-line at http://www.envirolet.com/
• Composting Toilets by Sunmar, www.sun-mar.com,

2-81 Install system to refill toilet with hand-wash water


1 POINT PER TOILET
2 POINTS MAXIMUM

2-82 Stub-in plumbing to use greywater or rainwater for indoor reuse


4 POINTS

The use of potable (drinking) water to flush toilets is not the best use of this limited resource. Although the use of
greywater for toilet flushing is not currently allowed by code, this is expected to change in the near future as
potable water resources in our region become more even more limited. Additionally, these systems are now
permitted with a variance on a case-by-case basis.

Greywater collection requires dual plumbing distribution lines and a storage tank. This Bonus Action item provides
the additional plumbing required to allow for future connection to greywater for toilet flushing.

Note: If you choose this Action item, you should also consider providing for the use of greywater for irrigation (see
Action item 2-65, Pre-plumb for greywater reuse for irrigation.

2-83 Install greywater or rainwater system for indoor reuse


8 POINTS

Using recycled water (normally greywater) for toilet flushing andrainw laundry conserves our valuable potable
water resources. Currently considered an “exception” allowed by code, the use of greywater for toilet flushing and
laundry may be approved on a case-by-case basis. This “experimental” system will require compliance with
stringent local and state regulations.

New systems can qualify builders for up to 25 points for each project in the checklist, see Action items, 2-65, Pre-
plumb for greywater reuse for irrigation, 2-41, Sub-Surface or Drip System Used for Irrigation, 2-67, Install
landscaping that requires no potable water for irrigation whatsoever after initial establishment period (approx. 1 yr),
excluding food production, see Resources for more information.
49
Resources
“Some chemicals in greywater can be harmful to plants” For more information, see 2-65, Pre-plumb for greywater
reuse for irrigation, above.

• Recommended Standards and Guidance For Water Conserving On-site Wastewater Treatment Systems,
Appendix D, Greywater Reuse, www.doh.wa.gov/ehp/ts/WW/GreywaterFact.PDF

2-84 Install a recirculating pump for domestic hot water w/ timer or motion sensor
2 POINTS

Recirculating pumps can be used with standard plumbing. The pump rapidly moves water from the water heater
to the fixtures, saving the water that is conventionally wasted while occupants wait for the water to heat up. In
addition to the convenience of on-demand hot water, this system can also save energy. The amount of energy and
water savings varies on the system use, controls, and the plumbing design. Select systems with manual controls
to avoid have the system operate continuously, which can waste hot water energy.

Resources
• Hot Water Recirculation Systems, www.toolbase.org/Technology-Inventory/Plumbing/hot-water-
recirculation.

2-85 Urinal is installed with a flush volume of 0.5 gallons or less


2 POINTS

The maximum flush volume for urinals in the U.S. is one gallon, and most urinals today use the full gallon. This
profligate waste led to the introduction of waterless urinals in the 1990s. In a sizeable office or institutional
building, a waterless urinal can save as much as 40,000 gallons (150,000 l) per year. However, most waterless
urinals rely on regular replacement of a vegetable-oil-based fluid and a disposable cartridge to maintain
performance of the sanitary trap. Keeping waterless urinals clean and preventing the deposition of uric salts in the
drain line has proven to be problematic.

Waterless urinals are gaining acceptance in many parts of the country and, if properly installed and maintained,
should prove satisfactory. Two companies, Caroma in Australia and Ecotech Water in the U.S., have introduced
waterless urinals that rely on a rubberized membrane that lets liquid through and then curls up to provide a
mechanical seal between uses. That seal allows rinse-water to be poured through the urinal periodically for
cleaning without washing away expensive sealant fluid.

As the market gains experience with waterless urinals, we can expect to see installation and operation guidelines
that improve performance and user satisfaction. Meanwhile, ultra-low-flush urinals will likely capture some of the
waterless urinal market share. EPA plans to offer a WaterSense label for high-efficiency urinals (HEUs), which are
likely to be defined as using 0.5 gpf (2 lpf) or less. (BuildingGreen’s GreenSpec Directory standard for urinals is
currently 0.25 gpf (0.95 lpf).

The Ecoblue Cube takes a very different approach to reducing water use in urinals, with a small cube-shaped urinal
cake that releases beneficial bacteria. These bacteria line the bowl, trap, and pipes, preventing odors and uric acid
deposition. If this product works, it could significantly reduce water use in urinals of all types by allowing them to
be flushed only periodically.

(Source: February 1, 2008 Feature “Water: Doing More with Less” from Environmental Building News)

Indoor Water Quality

2-86 Provide compost or worm bins instead of a food garbage disposal


50
3 POINTS

There are both environmental costs and benefits when using a garbage disposal.

Environmental costs:

• Waste from garbage disposers can overburden old municipal sewage systems. Americans throw away more
than 25 percent of the food we prepare, according to the Environmental Protection Agency. Garbage
disposers can double the volume of non-liquid material that goes down the drain, displacing food waste
from land to water. Many sewer systems around the country are more than 100 years old and operating
beyond their design capacity--resulting in more than 40,000 overflows of sewage treatment systems each
year. When these old systems fail, they can release raw sewage containing high levels of nitrogen,
chemical contaminants, and microbial pathogens into local waterways--causing harm to ecosystems,
animals and humans.
• Food waste also increases septic tank maintenance. If you have a septic system, using a garbage disposer
can mean emptying it twice as often. According to the Environmental Protection Agency, half of all septic
systems are at least 30 years old. As many as 20 percent or more are malfunctioning in some way, and 10
percent or more back up onto the ground surface or into homes each year. Failing septic systems are the
third most common cause of ground water contamination.
• Waste from garbage disposers can clog your drain or worse. Old plumbing systems can easily be
overburdened. You’ll want to check on the condition and capacity of your pipes before deciding to use a
disposer.
• A disposer uses more water. While garbage disposers are not going to have a large impact on your
household’s electricity use, they do require running water to move the waste down the drain—about 700
gallons per year.
Environmental benefit:

• Disposers can reduce the amount of solid waste that ends up in landfills and incinerators. A few
municipalities have actually encouraged consumers to install garbage disposers, especially in places where
water is plentiful, the sewage treatment infrastructure has been expanded and modernized, and landfill
space is scarce.
(Source: Garbage disposers: Green buying guide 7/09,
http://www.greenerchoices.org/printProduct.cfm?product=garbagedisposer)

Composting is an old technique that has made a comeback in recent years. The process turns organic wastes
(such as grass clippings and food waste) into humus, which is vital to soil fertility. About thirty percent of
household waste is compostable.

Worm bins are one technique that is growing in popularity. They are appropriate for treating primarily vegetative
food waste and small amounts of grass clipping. By providing homeowners with a compost or worm bin, you
promote this form of waste reduction. In addition, you provide the homeowner with an organic alternative to
chemical fertilizers typically used to boost soil fertility. Finally, this organic stream is not added to the sewer
system, by avoiding the need for sink disposal units.

You may want to build in a convenient method of collecting food waste in the kitchen. A covered “waste box” can
be installed next to the sink. Food waste can then be dropped through a chute into the bin underneath.
Additionally, new ready-made food chutes are now available that can be inserted into the kitchen cabinetry.

2-87 Install a whole house water filter system


2 POINTS

Generally, no one single whole house water filter can filter chemicals, microorganisms, and sediments. Find a dual
purpose “effective” product or design a multi-filter system to capture all contaminants. Whole house systems are
inline systems at the point of entry.
51
Whole house systems remove chlorine and other chemicals as they enter a home’s plumbing system. Like other
fixture-fixed water filters, these systems provide a higher quality drinking water, but they also alleviate the effects
of asthma and allergies by reducing chlorine in indoor air.

Resources
Ask your supplier.

2-88 Install water filtration system for consumptive use


2 POINTS

2-89 Install a chemical and salt free water softener system


2 POINTS

Hard water can cause residue build-up on fixtures and faucets. Calcium and magnesium chemicals in hard water
prevent soaps and detergents from lathering, which lead to build-up. Over time, scale can build up in plumbing
and appliances, which decrease their longevity. Chemicals released from conventional water supply can lead to
long term health effects. A water softener system can reduce these problems as well as save money long-term.

Conventional water softener systems consist of chemical or salt treatments. Research shows that these chemicals
and salt show up in local water bodies, affecting water quality. Alternative systems or “no waste” systems
generally work on the principal that rather than trying to remove calcium and magnesium from water, they simply
realign molecules into larger crystals, so that they don’t fall out of solution and cause pipe build-up. They do this
by forcing water to pass through a tube with a rough alloy surface inside of it—the roughness of the surface (and
the material it is made out of) encourages molecules to form into crystals. The larger crystals don’t gunk up pipes,
drains, toilets, etc, the water retains its healthful drinking qualities, and the water also doesn’t interfere with soap
lathering the way hard water does.

2-90 Separate outdoor water supply prior to filtration


1 POINT

By excluding water for exterior use from the filtration system, you will significantly reduce wear and tear, and the
rate of cleaning and replacement of filtration media. This will reduce cost and maintenance time for the
homeowner, and improve resource efficiency.

2-91 Provide spot water filtration using reverse osmosis or biodegradable carbon filter
in kitchen and bathrooms
1 POINT PER FIXTURE
3 POINTS MAXIMUM

Providing high-performance filtration, using reverse osmosis or comparable media filtration at the point of use
provides the best overall approach to water quality, since you filter only the water that is used for human
consumption and/or human hygiene.

ENVIRONMENTAL DESIGN CONCEPTS

Resources
• Cost Effective Home Building, A Design and Construction Handbook, NAHB Research Center, Upper
Marlboro, MD, 800-638-8556 or www.nahbrc.org.
52
• Green Development: Integrating Ecology and Real Estate, and Green Developments CD-ROM, Version 1.0,
Rocky Mountain Institute, Snowmass, CO. 970-927-3851 or www.rmi.org. Information on over 100 “green”
developments.
• NAHB Research Center’s “Tool Base Hotline” is available to answer builder questions, 800-898-2842,
www.nahbcrc.org/ToolBase.

2-92 Provide accessory dwelling unit or accessory living quarters


10 POINTS

An accessory dwelling unit (ADU), also known as a “mother-in-law” apartment or “granny flat,” is a small,
secondary unit on a single-family lot. ADUs are detached or separate from the living quarters (such as converted
garages). Accessory living quarters, on the other hand, are built into existing living quarters.

ADUs and accessory living quarters contribute to the versatility of the home-site and diversity of the
neighborhood. For example, they can be used to better adapt to changing family arrangements such as older
parents moving in with their children or grown children moving back into the house after college or life-style
change. They can also be rented to students or those with lower incomes; and for homeowners on a fixed income,
the rental income can help with a mortgage. Mixing this type of less expensive housing into established
neighborhoods reduces the demand for large apartment projects while also providing greater variety among
housing choices. They also promote density in urban areas.

Check with the local jurisdiction for requirements including minimum or maximum size or setbacks. Be sure to
include ADUs in your permit process.

Resources
• Green Development, p. 227 (listed above).

2-93 Maintain clear area to south of house for passive and active solar access
2 POINTS

2-94 Provide a covered front porch


3 POINTS

Front porches are elements of traditional neighborhoods that help extend living space outdoors, connecting
private and public spaces. Among other functional uses, such as providing summer shade, porches enhance
neighborhood safety by providing “eyes on the street.” Allowing the porch to encroach slightly into the front
setback makes the area more visually interesting for pedestrians without reducing the size of the backyard.

Resources
See resources listed under Design Alternatives above.

2-95 Position garage so it is not in front of house, while minimizing impervious


driveway area
3 POINTS

To receive points for this credit, you cannot locate the garage in the front, or in any way facing the street.

53
The best place to put the garage is behind the house (where it began as a carriage house). Alley access, if that’s
part of a new development or an element of the infill lot you selected, reduces the dominance of cars and
driveways in the front of the house, providing more visually interesting and safer sidewalks.

However, if alley access in not part of your development, you may wish to place the garage door openings to the
side of the house to present a consistent look for the front of the house. The driveway can easily lead to the side
entrance.

Resources
See Design Resources above.

• For information on varied garage placement and orientation, see


http://www.ci.salinas.ca.us/Admin/MuniCodes/CodeFiles/_DATA/CHAP37/Article_II__Base_District_Regul
ati/Sec__37_34__Low_density_reside.html.

2-96 Minimize garage size


2 POINTS FOR 2-CAR GARAGE
5 POINTS FOR 1-CAR GARAGE

Minimizing garage size may help to encourage people to consider alternate transportation methods like mass
transit, biking, or walking. It also helps to reduce the focus on having multiple cars.

Resources
See Design Resources above.

2-97 Build within ¼ mile of a transit stop


3 POINTS

When selecting sites for development, consider access to public transportation. Selecting sites that are within ¼
mile of a transit stop promotes the use of public transportation, which in turn provides environmental and
community benefits.

2-98 Design to promote and encourage pedestrian-friendly and safe neighborhoods


1 POINT PER MEASURE
5 POINTS MAXIMUM

There are many ways to create more pedestrian friendly and safe neighborhoods. The following are example of
design innovation and points awarded which will address this credit:

• Good visibility in front yard (no fences 5’ or higher) and front door visibility from street
• Accessibility for bikes (at least 1 access with no steps or curbs)
• Special bike storage designed into garage OR separate storage outside
• Edible landscaping in front yard/in planting strip/or install vegetable garden planter boxes
• Plant street trees in courtesy strip
• Build North Area of the Lot First, Retaining South Area for Outdoor Activities

2-99 Bury utility lines in common trenches


2 POINTS
54
2-100 Utilities are installed using one or more alternative means such as tunneling
instead of trenching, use of smaller (low ground pressure) equipment, or
geomats to spread the weight of construction equipment, shared utility trenches
or easements, and placement of utilities under streets instead of yards.
5 POINTS

2-101 Use dark sky compliant fixtures to minimize night glare


1 POINT
CREDIT NOT AVAILABLE WHERE REQUIRED BY LOCAL CODE

2-102 Build on a lot that is within ½ mile of at least six essential services
3 POINTS

Examples

• Grocery store
• post office,
• place of worship,
• community center,
• daycare center,
• bank, school,
• restaurant,
• medical/dental office,
• laundromat/dry cleaner, etc

2-103 Driveways or parking are shared between multiple units


4 POINTS

2-104 Proximity to bike amenities within 1 mile


3 POINTS

Extra Credit for Site and Water

2-105 Extra credit for innovation in Site and Water


1-10 POINTS

You may submit a site or water saving strategy or system, not specifically called out in this Section, for
consideration for an Extra Credit for Innovation. All extra credits will be approved by the Program Director. If
approved, add up to 10 points to your Section total

55
Section 3 ENERGY EFFICIENCY

General Resources
• For Washington State Energy Code and Ventilation and Indoor Air Quality Code resources, see Section One Resources: Build to
“Green” Codes and Regulations in Part II of this Handbook.
th
• Washington State Energy Code Builder’s Field Guide, 6 edition 2004. Available through WSU Cooperative Extension,
Educational Materials. To order, call 360-956-2000. This guide is available in PDF for free on the Internet
http://www.energy.wsu.edu/documents/code/bfg/2004/BFG_Full_2004.pdf.
• “Energy Ideas Clearinghouse.” The EIC is your library for information on energy efficient construction. EIC will provide
customized responses to specific questions about energy efficiency, moisture control, ventilation, and green building. 800-872-
3568 or e-mail EnergyLine@energy.wsu.edu. Or you can browse for resources yourself online at www.energyideas.org. The
EIC is funded by the Northwest Energy Alliance, Olympia, WA, www.nwalliance.org.
• Formerly known as the Energy Efficiency and Renewable Energy Network (EREN), the site is now US DOE Energy Efficiency
and Renewable Energy (EERE)., a source of free information from the Department of Energy, www.eere.energy.gov
• NAHB Research Center’s “Tool Base Hotline” is available to answer builder questions, 800-898-2842,
www.nahbcrc.org/ToolBase.
• The Florida Solar Energy Center has done extensive research and testing on a range of issues related to energy efficiency in
buildings, including comparisons of different building systems, 407-638-1000 or their website at www.fsec.ucf.edu.

Product Information
• GreenSpec—The Environmental Building News Product Directory and Guideline Specifications, E Build, Inc., Brattleboro, VT, 802-
257-7300 or www.buildinggreen,com. GreenSpec is organized in standard CSI Divisions. Environmental Building News also
offers product reviews, information, and also posts some journal articles at
www.buildinggreen.com/products/productslist.html.
• REDI Guide (Resources for Environmental Design Index), web database, diskette, or printed handbook; a good resource for
energy-efficient products. Available from Iris Communications, Eugene, OR, 800-346-0104, or online at
data.oikos.com/products.

Software
• Building Energy Software Tools Directory is available from EERE at
http://www.eere.energy.gov/buildings/tools_directory/countries_sub.cfm.
• Energy Gauge, http://energygauge.com/, 1679 Clearlake Road, Cocoa, FL, 321-638-1492. Approved for 2007 edition.
• RemRate, available from Architectural Energy Corporation, http://www.archenergy.com/products/remrate, 2540 Frontier
Avenue, Suite 201, Boulder, Colorado 80301, 303-444-4149. Approved for 2007 edition.

Technical Books and Guides


• Builder’s Guide, by Joe Lstiburek. Published for four climate versions (For Pacific Northwest, appropriate climate type is
“Mixed-Humid.”) The guide includes illustrations and resources for such subjects as house layout and design, foundations,
framing, HVAC, insulation, drywall, plumbing, electrical systems, painting, sheathings and windows all with respect to
moisture control, energy efficiency and proper ventilation. Published by and available from Building Science Corporation,
Westford, MA, 978-589-5100, or http://www.buildingsciencepress.com. Cost is $40.00 plus S&H. Also available from the
Journal of Light Construction Bookstore, 800-859-3669, or online at http://jlc.buysub.com/.
• Iris Catalog, publications, videos and software for the building industry, from Iris Communications, Eugene, OR, 800-346-0104
for a free printed catalog or browse the online at shop.oikos.com/catalog.

56
• No-Regrets Remodeling: Creating a Comfortable Healthy Home That Saves Energy (1997), published by Home Energy Magazine
(See www.homeenergy.org/booksnguides) Cost is $19.95 U.S. (plus $3.50 S&H). To order, call 510-524-5405.
• Twenty-First Century Townhouses: An Illustrated Guide, NAHB Research Center, Upper Marlboro, MD. Cost is $10.00 for the
book and $25.00 for the video. To order, call 800-638-8556 or order online at eshop.nahbrc.org/cgi-bin/nahbrc.storefront.

Solar
• Passive Solar Buildings, ed. by J. Douglas Balcomb, MIT Press, 1992. ($70.00 at amazon.com).
• Passive Solar Design and Construction Handbook, by Steven Winter Associates. Published by John Wiley & Sons, 1997, ISBN:
0-471-18308-3. To order from John Wiley & Sons, call 800-225-5945 or e-mail catalog@wiley.com or order online at
catalog.wiley.com. Cost is $90.00 plus S&H. Also available from Iris Communications, 800-346-0104 or online at
shop.oikos.com/catalog.
• The Passive Solar House. Ten “solar principles” highlight key concepts. Includes a series of worksheets and extensive tables.
Available from Iris Communications, 800-346-0104, or www.oikos.com. ($25.00)
• The Residential Building Design and Construction Workbook, available from Cutter Information Corp. in Arlington, MA. 800-964-
5118 or www.cutter.com.

OVERALL

3-1 Document a reduction in overall home energy use using approved energy
modeling software
1-50 POINTS

1 POINT PER 1% IMPROVEMENT OVER CODE

Approved Modeling Software:

• WSU UA Alternative Worksheet

• REM Rate

• Energy Gauge

• TREAT

• ResCheck

• Other software may be allowed upon prior approval

3-2 Build a zero net energy home that draws zero outside power or fuel on a net
annual basis (based on modeling)
50 POINTS

A Zero Net Energy Home combines state-of-the-art, energy-efficient construction and appliances with renewable
energy systems such as solar water heating and electricity resulting in a house that produces as much or more
power than it consumes. Generally, Zero Net Energy Homes are connected to the utility grid, with energy
consumption measured on an annual basis, allowing for excess energy produced to be sold back to the utility.

57
Zero Net Energy Homes optimize climate-specific design, passive solar heating and cooling, solar thermal and
solar electric systems (active solar), and energy efficient construction, appliances, and lighting. The goal of this
strategy is performance-based, so you must use other Action items in this section, as well as other sections from
the checklist, as part of your plan to achieve a net zero energy consumption rate for the home. For instance,
geothermal heating might help the house achieve net zero along with photovoltaic power generation, an
advanced shell design, a super high efficiency distribution system, and exceptional ventilation to reduce cooling
loads.

• Building a net–zero home is possible with the Inland Northwest climate conditions, but requires much up-
front planning to ensure ultimate performance of the home. Coordination with the local utility is also
required regarding the potential for feeding and selling excess energy into the grid. To guarantee that the
home achieves net-zero performance, consult with a third party verifier and submit the verification results
to the HBA along with the completed Built Green Checklist for the home. Refer to the resources section in
Part II for a list of HBA approved Third Party Verifiers.
Program note: wood burning heating options do qualify for zero-net energy IF it comes from pellet stoves or EPA
certified stoves. Absolutely no Russian or Rumsford stoves allowed. “Creative” fireplaces use electric power and
can be used in place of traditional fireplaces.

Resources
• DOE Building Technologies Program, http://www.eere.energy.gov/buildings/.
• “Moving Toward Zero Energy Homes” by U.S. Department of Energy's Office of Energy Efficiency and
Renewable Energy. Available online at www.eere.energy.gov/buildings/info/documents/pdfs/35317.pdf.
• “On the Path to Zero Energy Homes ” by U.S. Department of Energy's Office of Energy Efficiency and
Renewable Energy. Available online at
www.eere.energy.gov/buildings/building_america/pdfs/29915_zeb_path.pdf.
• National Renewable Energy Laboratory's (NREL) Photovoltaic (PV) research (http://www.nrel.gov/pv/)
provides “A Consumer' s Guide to Buying a Solar Electric System,”
http://www.nrel.gov/docs/fy99osti/26591.pdf.
• The Net-Zero Energy Home (NZEH) Coalition, www.netzeroenergyhome.ca/
• “The Near-Zero-Energy House” by Solar Today, May/June 2005. Available online at
www.solartoday.org/2005/may_june05/ZEH.htm.

ENVELOPE
Thermal Performance

3-3 Document envelope improvements beyond code (UA Alternative approach)


1 POINT PER 1% IMPROVEMENT OVER CODE
40 POINTS MAXIMUM

The current Washington State Energy Code allows three possible approaches to demonstrate compliance. Check
with Washington State Energy Office for the most recent updates in the Energy Code.

The UA Alternative Approach allows you to trade off the thermal efficiency of one component for another. It
compares building envelope heat loss rates of the proposed house design to a Code-defined reference house.

The Washington State Energy Program (WSU) and your local building department have developed spreadsheets
to calculate performance using this approach.

58
Use a spreadsheet, or code forms to document improved performance (Total UA {area x U-Factor} of the proposed
building / UA of the WSEC code reference building). Score one point for each percent of energy saved, calculated
as follows:

Divide your proposed total UA by the Target UA Total. Subtract that number from 1, and multiply the result by
100, rounding to the nearest number. That is the number of points you will take.

Example: If your Proposed UA Total is 205, and the Target UA Total is 235, divide 205/235, the result will be .8723.
Subtract this from 1, and you get .1277. Multiply by 100, and you get 12.77. Round to 13, and score 13 points.

Resources
Document results using Chart 3-A, “BUILT GREEN Component Performance Method “ in the Appendix. Provide a
completed copy of Chart 3-A to the homeowner as part of their Operations & Maintenance Kit.

• http://www.energy.wsu.edu/documents/code/CPWorksheets/CPWorksheet_instruct.pdf

3-4 Document envelope improvements beyond code (prescriptive approach)


1-40 POINTS

Use the prescriptive approach and Chart 3-B, provided in Appendix, to note the actions you will to take to improve
efficiencies above and beyond that prescribed by the energy code for building components. Note the efficiencies
you expect to achieve.

See Chart 3-B for point assignments, which are based on measures taken (range is 1 to 55 points).

The prescriptive approach is the simplest method of code compliance. There are two different forms for
documenting prescriptive code compliance.

The original chart was produced using a base model home and the component trade off method. Each measure is
input individually, and the upgrade is assessed in the same manor at Chart 3-A, see above.

See Appendix Section for weblinks that can help you with the new code changes.

Resources
See Chart 3-B, “BUILT GREEN Prescriptive Scoring Method Upgrades for ‘Other Fuels” in the Appendix.
th
• Washington State University Cooperative Extension Builder’s Field Guide, 6 Edition contains
“Prescriptive Approach – Simple Form for the Washington State Energy Code (2004 Second Edition),
Climate Zone 1, by Washington State University Cooperative Extension Energy Program. Available online
at www.energy.wsu.edu/documents/code/wsec2004/Simple1.pdf.

3-5 Home is ENERGY STAR Homes Northwest certified


10 POINTS

ENERGY STAR Northwest Homes is a joint program of the Environmental Protection Agency (EPA), the
Department of Energy (DOE), and the NW Energy Efficiency Alliance to promote smart consumer choices for
products, building upgrades, and homes that go beyond our already stringent local codes to save money while
preventing pollution.

As Built Green members, builders agree to construct new homes that offer a 15% improvement in energy
consumption over WEC compliance. Once a home’s performance is verified by an independent, third-party expert,
the home can bear the ENERGY STAR label.

59
Contact Dave Hetherington, Sr. Program Manager for Northwest ENERGY STAR, for current information; By
phone at (503) 808-9003 ext 103 or via email at DHetherington@fluidms.com.

For details of the specification of this program, please see Error! Reference source not found..

Table 3-1 Pacific NW ENERGY STAR New Construction Specification for Site-built, Single Family Dwellings

COMPONENT WA NW REQUIRMENTS

Envelope Path Ducts Inside Path Equipment Path


Ceiling R-49 (R-29 at the Edge) R-49 (R-29 at the Edge) R-49 (R-29 at the
Edge)
Above Grade Wall R-21 + R-5 Exterior R-21 R-21
Foam
Below Grade Wall R-21(interior) or R - R-21(interior) or R - R-21(interior) or R -
10(exterior) 12(exterior) 12(exterior)
Slab R-15 (2ft. perimeter) R-15 (2ft. perimeter) R-15 (2ft. perimeter)
Window U-.25 U-.30 U-.30
Glazing Area 21% 21% 21%
Heating System 9.0 HSPF 9.0 HSPF 9.0 HSPF
92 AFUE 92 AFUE 94 AFUE
Water heating system Gas 0.61 EF/ Gas 0.61 EF/ Gas 0.82 EF/
Elec 0.93 EF Elec 0.93 EF Elec 2.0 EF
Framing Type Int. Framing, 6 sided V- Adv. Framing or R-5 Adv. Framing or R-5
Walls Exterior Foam, 6 sided Exterior Foam, 6 sided
V-Walls V-Walls
Envelope Tightness 4.0 ACH @50 Pa
Ventilation Central Exhaust or HRV
Duct Tightness 3.75% @25Pa, 6% @ Not Required 3.75% @25Pa, 6% @
50 Pa, or 75cfm 50 Pa, or 75cfm
Lighting 80% CFL or Pin-based
Appliances All built-ins are ENERGY STAR
Plumbing 1.75 gal/min (shower head), 1.0 gal/min (faucet)
See Section Three Resources in Part II for the website providing more information about this program and how to
join.

by the HBA, refer to the Section Three Resources in Part II of this handbook.

3-6 Install no more than 1% of conditioned floor space of skylights, or NO skylights


1 POINT IF SKYLIGHTS ARE LESS THEN 1% OF CONDITIONED FLOOR SPACE
2 POINTS IF NO SKYLIGHTS

Because skylights use sunlight in addition to daylight, they can be three to ten times smaller than a window while
collecting the same amount of light. Beyond a certain skylight to floor ratio, increases in heating and cooling loads
can outweigh lighting energy savings, thus increasing the overall energy use of the home. Installing no more than
1% of the floor space with skylights provides optimum daylighting while maintaining the overall energy efficiency
of the envelope.

See the Resources Section in Part II for references to Skylighting Guidelines and an excel program, called SkyCalc
that can be used to determine the most effective skylight design for your project.

Resources
60
• “Modular Skylight Guidelines and Report” by The Heschong Mahone Group, Inc. is available at
http://www.h-m-g.com/downloads/.
• “Design Guidelines: Skylighting Guidelines” by Energy Design Resources,
http://www.energydesignresources.com/resource/140/.
• SkyCalc software by Energy Design Resources, available online at
www.energydesignresources.com/resource/129/.

3-7 Skylights minimum of U-0.2


5 POINTS

3-8 All windows w/ minimum of U-0.20


10 POINTS

3-9 Design with low window to floor ratio (<12%)


3 POINTS

3-10 Install full continuous rigid insulation beyond code beneath any slabs on grade
5 POINTS

3-11 Install dense-packed cellulose (over 2.5 lbs/inch), wet-blown cellulose, blown-in
foam, fiberglass BIBS, or blown-in fiberglass as insulation
5 POINTS

To receive credit for this Action item, insulation can be cellulose, wet-blown cellulose, blown-in foam, fiberglass
bibs, or fiberglass. This installation provides the ideal thermal stop and reduces air leakage.

Blown-in insulation products, including cellulose or Icynene, have an advantage over fiberglass in that they
provide better penetration and filling of cavities and are made from non-toxic materials. The insulation can be
dry-blown or poured loose-fill into enclosed cavities, but is most commonly wet-sprayed. When sprayed, the
product leaves few voids, reducing problems with air infiltration. Blown insulation must be carefully installed to
prevent “overblowing,” which reduces the R-value for a given, installed thickness. Careful installation of blown
insulation in attics assures even coverage, avoiding high and low areas with varying R-values, and avoids blocking
ventilation paths. Ask how the insulation contractor controls for the proper amount of insulation material and
depth.

Fiberglass Blown-In-Blanket (BIB) is similar to "wet-spray" cellulose in that the material is mixed with latex
adhesive, misted with water to activate the glue, and blown into wall stud cavities. Over time, cellulose in attic
installations may settle and lose its R-value, to compensate for this, it is recommended to install 20% more in this
area. Check the manufacturer’s claims regarding “settled thickness” recommendations. For wall cavity
applications, research indicated that it is possible to install without settling, so long as initial installation was done
to proper density.

Cellulose can also be dry-packed into wall cavities. Cellulose insulation is made from 100% post-consumer
recycled newspapers or telephone books and is usually combined with boric acid or sodium borate as a fire
retardant. An additional benefit of boric acid is that it kills carpenter ants and termites. See also Action items 5-

61
115, All insulation to have a minimum of 40% recycled-content, and 5-116, Use Environmentally Preferred (EPP)
Insulation Products (Formaldehyde-Free, CFC-Free, HCFC-Free).

Soy Based Foam insulation expands to 100 times its volume to fill every space and void and create a barrier and
thermal seal. It is not affected by moisture, mold, insects or rodents, and is produced from plant-based and
recycled renewable resources that reduces demand and dependence on non-renewable petroleum reserves. It is
usually water blown, has no VOC's nor does it contain urea or ozone depleting CFS's or HCFC's, doesn’t settle, and
provides an R-Value of 3.6 per inch or greater. It also has a high fire class rating, at Class 1.

Installation usually involves using special equipment that blows the insulation through and into the cavities or
attic space. Generally professional installers ensure proper density and complete coverage. See the Resources
Section for references to help determine proper density. If you contract with a professional insulation installer,
have them include air-sealing in the estimate. See Action item 3-15, Use Airtight Drywall Approach to Framed
Structures.

Other considerations to think about are selecting the appropriate material for areas around pipes, remembering
not to cover eave vents in attic installations, and wearing protective clothing and respirators based on the
material you choose.

Resources
• “Loose-Fill Insulation” by U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy.
Available online at
www.eere.energy.gov/consumer/your_home/insulation_airsealing/index.cfm/mytopic=11650.

3-12 Install frost-protected shallow foundation, minimum R-10 insulation


5 POINTS

Frost-protected shallow foundations (FPSF) have been used in some of the coldest climates in the world to
improve energy efficiency through moderating the temperature of the foundation. FPSF also reduce construction
costs while achieving the same impact as sinking foundations below the frost line. Implementing a frost-protected
shallow foundation still affords protection to the foundation from frost heaves, while reducing the amount of
excavation and construction material needed to extend foundations below the frost line. In heated buildings the
insulated foundation uses the radiated heat from the building and the underlying earth to reduce the impact of
frost. For unheated buildings, such as garages latent heat from the ground is enough to reduce the chance of
possible frost heaves. When implementing FPSF follow IRC design guidelines and specifications.

62
Figure 3-1 Heat Exchange Occurring at an insulated building foundation

Figure 3-2 A frost protected shallow foundation in comparison to a conventional house foundation.

http://oikos.com/esb/43/foundations.html

3-13 Skylight shafts insulated to R-38, covered with GWB, OSB or other rigid
sheathing to prevent air movement through the insulation from degrading the
insulation value
2 POINTS

3-14 Specify and use raised-heel trusses (>= 8in.) or SIPs roof, to allow full insulation
over conditioned space
2 POINTS

63
Use full-depth insulation to the outer edge of conditioned space, using a raised-heel truss or extended truss work
at least 6” over exterior wall/top plate. The specification of energy heels in the original truss order should not add
costs. Figure 3-3 provides options to maintain full heel insulation (advanced frame ceiling).

Figure 3-3 Construction Details, Full Heel Insulation


(Source: Washington State Energy Code Builder’s Field Guide)

Resources
The figure provides options to maintain full heel insulation (advanced frame ceiling).

• Washington State Energy Code Builder’s Field Guide. See Chapter 3, ―Framing,ǁ (listed in General
Resources above).

Air Sealing
Proper air sealing can have a major impact on energy savings. Department of Energy estimates that up to 30% of
a home’s energy can be lost through air leaks. Typical areas for sealing include under sill plates, around windows,
doors, framing members, and electric, plumbing and mechanical penetrations. Sealing materials, which include
caulking, sealant, foam, and tape, are easy to find and inexpensive.

64
Please note that “tightening” the home to save energy requires careful attention to indoor air quality.
Providing an adequate, controlled supply of fresh air to the home is addressed in Section Four: Health and Indoor
Air Quality.

3-15 Airtight drywall approach for framed structures using thermal enclosure checklist
3 POINTS

The airtight drywall approach (ADA) for framed structures is an advanced sealing package that goes beyond basic
practice. Specifically, it includes caulk or gasket drywall installed on exterior walls at the top and bottom plates,
windows and doorframes; caulk or gasket drywall installed on interior walls at intersections with exterior ceilings;
and caulk or gasket electrical, plumbing or mechanical penetrations in the drywall.

Proper attention should be given to the quality and durability of the sealing materials as well as the type of sealant
for the size of the gap. Install quality, self-closing dampers on vents to prevent backdrafts on windy days.

Resources
• Advanced Framing, Techniques, Troubleshooting, and Structural Design. 46 Selections from the Journal of
Light Construction, pp 274-276. Order at 800-859-3669 or www.jlconline.com/bookstore.
• Builder’s Guide, by Joe Lstiburek (See Resources, Technical Books and Guides, above).

3-16 Blower door test results better than 3.5 ACH50 (5 points), or 2.5 ACH50 (10
points)
NOT APPLICABLE IF CLAIMING UNDER WSEC TABLE 406.2

THIS CREDIT IS ONLY AVAILABLE IN CONJUNCTION WITH ACTION ITEM 4-64, AND THE INSTALLATION OF A
WHOLE HOUSE FAN BEYOND CODE REQUIREMENTS.

5 POINTS IF BLOWER DOOR TEST RESULTS IN BETTER THAN 3.5 ACH50


10 POINTS IF BLOWER DOOR TEST RESULTS IN BETTER THAN 2.5 ACH50

65
Blower door tests are used to both identify air leakage paths in a home and to quantify air leakage ranges. Blower
doors are also used to locate duct leaks.

A blower door consists of a variable speed fan sealed into an exterior doorway and used to blow air into or out of a
house. When air is blown out of the house, the house develops a slight negative pressure (or vacuum) relative to
outside. The pressure differential drives outside air into the house (infiltration) through any available openings in
the exterior shell. These leaks can be located by touch or with smoke, then sealed.

In addition, the pressure induced by the blower door can be used to yield a quantitative estimate of the
“leakiness” of the home (in square inches). Additional calculations yield the approximate natural air change rate
(ACH).

Blower door tests of homes built to code average 0.34 ACH. Reducing to 0.30 ACH through improved air sealing
will reduce annual energy use by about 8% and is very achievable. (Homes with forced air systems will have a
slightly higher ACH.)

It’s best to do a blower door test once just before sheet rock and once after sheet rock, but before attic insulation
is blown in.

Resources
Blower Door Testing, a seven-minute video, demonstrates generic blower door set-up procedures and shows how
to conduct air leak diagnostics using smoke sticks; also includes examples of many air leakage sites. Available
from Iris Communications, Eugene, OR, 800-346-0104 or www.shop.oikos.com/catalog, $(15). Many full-service
heating contractors will perform blower door tests.

Blower door manufacturers include:

• The Energy Conservatory, Minneapolis, MN, 612-827-1117. See


http://www.energyconservatory.com/articles for links to articles is Home Energy Magazine about blower
doors and testing.
• Infiltec, Falls Church, VA, 703-820-7696 or 540-943-2776, or www.infiltec.com.
• Retrotec, Bellingham, WA, 360-738-9835 or www.retrotec.com.

3-17 Use an air barrier on the exterior wall assembly installed per manufacturers
guidelines
3 POINTS

Exterior Air Barrier – An air barrier material is any House Wrap, sprayed applied fluid or other building material with
air permeance less the or equal to 0.02 L/(s·m2) @ 75Pa (0.004 cfm/ft2 @ 1.57 psf) as measured in accordance to
ASTM E2178 Standard Test Method for Air Permeance of Building Materials. Material should be installed
continuously on building walls according to manufactures guidelines regarding detailing, taping of seams and
fastening method.

Adding an External Air Barrier has many long term performance characteristics to a building envelope.

Improved Comfort: A tighter building envelope reduces the drafts and can maintain a more consistent level of
comfort throughout the house.

Improved Indoor Air Quality: A tighter building envelope reduces the infiltration of moisture and outdoor air
pollutants.

Lower Energy Bills: Air leakage accounts for 25% to 40% of the energy used for heating and cooling. Installing the
air barrier on the exterior of a wall surface also reduces the “wind washing” effect which helps to protect the
designed R-Values of the insulation products used in the wall system.

66
Reduced Condensation Issues: A tighter building envelope can reduce the amount of air transported moisture
which can condense on cold surfaces within the envelope.

Reduced Obsolescence: Tighter building envelopes are expected to become standard practice for the building
industry

Reduce Thermal Bridging


Where framing members make full connection between the interior drywall and exterior sheathing, a cold spot
forms. These areas increase heat loss, reduce comfort, and increase condensation on interior surfaces. In addition,
cold spots attract dirt and will soil faster.

Limit the number of framing members that fully bridge the interior and exterior surfaces to save energy and
produce a more comfortable home. The thermal bridges that allow heat to escape include solid headers over
doors and windows and other paths for conductive heat loss.

3-18 Use insulated headers


1 POINT

As much as 4% of the area of the typical building envelope consists of window and door headers. Insulated
headers reduce thermal transfer (bridging) found in standard construction using solid wood headers for exterior
window and door openings (see Figure 3-4). Although they can be purchased pre-assembled, they are often built
on-site by sandwiching rigid insulation between the lumber. Using insulated headers achieve higher R-values
without sacrificing structural integrity.

Typically, 4x and 6x have been used for header stock, but they should only be used when structurally necessary.
Doors in non-load bearing walls do not require structural headers. Building codes allow these practices and
recognize this proven performance.

If you use a King Stud and insulated header or a let-in header with framing clips instead of cripple studs, you save
lumber and there will be more room in your walls for insulation.

67
Figure 3-4 Insulated Headers
(Source: Washington State Energy Code Builder’s Field Guide)

Note: Points are awarded only for improvements that are above and beyond Washington State Energy Code
requirements.

Resources:
• Washington State Energy Code Builder’s Field Guide, See Chapter 3, “Framing,” (listed in General Resources
above) as well as references listed in the Field Guide.
• Ask your local building supply house for “The Nailer,” a recycled-content plastic drywall clip that is wider
and easier to use than many other clips. It can be installed with a stapler using 1/2-staples.

3-19 Where applicable, use 2-stud instead of 3-stud corners, and fully insulate corners
1 POINT

68
Of the 3-studs usually placed in corners, only one is required for the structural load. The others are used for
drywall backing for the interior and exterior sheathing. Constructing 2-stud corners reduces material use and
leaves additional space for insulation. (see Figure 3-5). Drywall clips spaced two feet apart can provide back-up for
interior finish materials. Place the clips where one wall abuts another, or where two walls intersect at corners.

Figure 3-5 Corner Construction


(Source: Washington State Energy Code Builder’s Field Guide)

Resources
• Washington State Energy Code Builder’s Field Guide, See Chapter 3, “Framing,” (listed in General Resources
above).
• Ask your local building supply house for “The Nailer,” a recycled-content plastic drywall clip that is wider
and easier to use than many other clips. It can be installed with a stapler using 1/2ǁ staples.

3-20 Fully insulate at interior/exterior wall intersection by open cavity framing


1 POINT

Optional framing details provide for easy placement of insulation. Ladder Blocking can also be used to create
room for insulation. Refer to the Washington State Energy Code Builder’s Field Guide.

69
Figure 3-6 Construction Details for Easy of Insulation
(Source: Washington State Energy Code Builder’s Field Guide)

Resources
See Chapter 3, “Framing,” in Washington State Energy Code Builder’s Field Guide (listed in General Resources
above).

3-21 Use structural insulated panels (SIPs), insulated concrete forms (ICFs) or straw
bale for exterior walls around conditioned space
10 POINTS

Because SIPS contain few framing members, they have fewer thermal bridges than conventional wood frame
construction. Do not select SIPs made with CFCs. See Action item 3-15, Use Airtight Drywall Approach for Framed
Structures for more information.

ICFs are rigid plastic forms which hold concrete in place afterward to function as thermal insulation in concrete
walls. Typical insulation values range from R-17 to R-26 compared to R-13 to R-19 for most wood-framed walls.

Straw bale insulation provides an excellent, non-toxic insulation. It is predicted that a straw bale home can save as
much as 75% of energy costs resulting in savings to homeowners and reduction of fossil fuels and CO2 emissions.

70
3-22 Use exterior rigid insulation beyond code
2 POINTS

Rigid foam insulation has the highest R-value per inch of any common type of insulation. Applying the foam to
cover all of the wood framing reduces thermal bridging associated with batt or blown-in insulation. Another
approach that essentially eliminates the thermal bridges of framing lumber is to use continuous rigid foam
insulation as an exterior sheathing material. This approach is particularly useful where local code requirements
require the use of additional framing materials for severe seismic and wind load requirements. It can be used to
meet energy code requirements for wall R-values using a 2x4 wall with 2” of extruded polystyrene (XPS), or to
raise both the nominal R-value and the whole-wall R-value of a 2x6 wall with rigid foam generally between 1/2”
and 2”.

• Use rigid foam that is vapor retardant (e.g. XPS), not a vapor barrier (e.g polyisocyanurate or foam backed
product) to allow walls to dry to the outside in winter;
• Rigid foam can provide an effective drainage plane and must be flashed, and sealed and taped at seams.
Alternately, an externally applied house wrap or builder paper may be used for the drainage plane;
• Foam may replace wood sheathing, reducing material costs:
• Use let-in wood or steel bracing for stability and to meet required sheer performance;
• Plywood may be required in some locations to meet sheer requirements. Use thinner sheets of foam to
shim over these panels;
• Fasteners for siding and trim must be long enough to penetrate foam and required depth of wood;
• Use siding that only requires fastening at required stud spacing (16” or 24”) if using only foam for
sheathing;
• At rough openings, flashing details and window/door placement should be moved outward to align with
the drainage plane;
• Cantilever gable truss to line up with face of foam sheathing by sistering a bearing block to the bottom
chord, bearing on the framing top plate;
• Adequately protect foam from pest infestation at bottom of wall.

71
3-23 Use advanced wall framing, 24-inch on-center, w/ double top plate
3 POINTS

Advanced Wall Framing is a code recognized process that incorporates 24-inch on-center framing with increased
insulation. Other features include two-stud corners and intersections or other means of fully insulating corners
and one stud is used to support each header (see Action item 3-19, Where Applicable, Use 2-Stud Instead of 3-Stud
Corners, and Fully Insulate Corners), insulated headers consist of double 2x material with R-10 insulation between
the header and exterior sheathing. Sandwich headers are common using advanced framing techniques, and full
insulation where interior partition walls meet exterior walls (see Action item 3-20, Fully Insulate at Interior/Exterior
Wall Intersection).

To help increase the efficiency of exterior walls, use ladder partitions. The usual practice of adding extra studs in
the exterior wall to provide nailing for drywall creates an inaccessible pocket that can’t be insulated after exterior
72
sheathing is installed. In ladder partition, the horizontal blocking across the front of the wall cavity allows for
plenty of insulation behind. This alternative saves lumber and improves R-value.

On average, advanced framing uses 30% less lumber, takes less time to construct and costs less to build because
the reduced use of lumber more than offsets the additional cost of header insulation. Construction cost savings is
estimated at $0.29 per square foot of wall area. Total savings for this measure alone are 2 to 4% of total energy
use.

You’ll need to use sheathing, siding and drywall rated for 24-inch stud spacing. Fewer studs mean fewer plumbing
and electrical penetrations and fewer nail or screw holes to seal and sand. Although more insulation is required,
wider stud spacing results in fewer pieces of insulation and therefore faster installation.

Tip: To eliminate concerns about “wavy walls,” install exterior sheathing horizontally rather than vertically.

To receive credit must be at least 85% of Building Envelope

Figure 3-7 Advanced Framing

Resources
• Washington State Energy Code Builder’s Field Guide. (See General Resources, above.) See Framing Chapter.
• Builder’s Guide, by Joe Lstiburek. (See Resources, Technical Books and Guides, above.)
• Advanced Framing, Techniques, Troubleshooting, and Structural Design. Published by the Journal of Light
Construction. A good general reference for advanced framing. Covers a broad range of topics on tools,
building layout, floor, wall, and roof framing, engineered lumber, energy details and more. Available from
the Journal of Light Construction Bookstore, 800-859-3669, fax 802-434-4467 or online at
www.jlconline.com/bookstore.
• See Super Good Cents Builder’s Guide to Energy-Efficient Construction for information on advanced air
sealing techniques. Available from Bonneville Power Administration, 800-622-4520 ($10).
• For information about efficient (or “Advanced”) framing, contact the Energy Ideas Clearinghouse (See
General Resources, above.)

3-24 Use advanced wall framing—24-in on-center framing, w/ single top plate

73
4 POINTS

As an alternative to 3-23, using Advanced Framing with a single top plate, further reducing thermal bridging and
materials usage.

This approach requires stacked framing so that rafters, trusses, joists and studs are vertically aligned to properly
transfer loads through the frame to the foundation.

3-25 Use drywall stops or clips for backing


1 POINT

3-26 Innovative stick framing to reduce thermal bridging, by methods such as double
wall framing and horizontal wall furring
3 POINTS

TO RECEIVE CREDIT MUST BE AT LEAST 85% OF BUILDING ENVELOPE

There are other innovation stick framing alternatives that reduce thermal bridging. Double Wall Framing provides
for load bearing interior wall and a lighter framed exterior wall that supports the exterior finishes. This technique
allows for a wide range of higher insulation values. The primary benefit of this technique is that it thoroughly
reduces thermal bridging.

Rigid foam insulation has the highest R-value per inch of any common type of insulation. Applying the foam to
cover all of the wood framing reduces thermal bridging associated with batt or blown-in insulation. In addition,
foilfaced sheathing and extruded polystyrene sheathing retard movement of water vapor. First, vertical studs
carry the load. Then the horizontal framing goes over the vertical studs to make the wall thicker and where
additional insulation is installed. Because the two framing layers only touch at intersection, there is an increase in
efficiency. Installing horizontal wall furring strips accelerates drying of rain-wetted siding to minimize moisture-
associated problems in the envelope.

74
Figure 3-8 Double Wall
(Source: Washington State Energy Code Builder’s Field Guide)

Resources
See General Resources above, particularly the field guides.

3-27 Free air movement in attic or on site framed roof systems exceeding code by 15%
10 POINTS

3-28 Install storm door system with magnetic seal


3 POINTS

75
Solar Design Features
Good solar design can reduce heating bills and eliminate the need for mechanical cooling. Solar features also
provide consumers with attractive natural lighting and reduce interior temperature swings. However, solar design
is a comprehensive practice. If you approach it piecemeal, you may end up overheating the home, causing
discomfort and increasing the demand for cooling.

To be effective, solar strategies must be considered during the design phase of a project. By placing
approximately 50% of the glazing on the south side of the structure and including thermal mass features in the
living space of the home, you can achieve 20% savings in energy. (There may be additional cost in construction for
these features.) Simple, easy-to-use software is available to help the designer optimize the solar design.

3-29 Orient home on site to optimize passive solar strategies


5 POINTS

The best use of solar energy on site involves many aspects, such as building orientation, building design, and
landscape placement. The long walls of a home (and windows in those walls) absorb the most heat from solar
radiation. Orient buildings so that longer walls face north and south, so that they can be protected from the high
angle sun using roof overhangs. The east and west walls are exposed to lower angle sun, which can be blocked
with vertical shading, fences and deciduous plantings that will shade in summer, but let sun through in winter.

Homes are generally located on a site to maximize views and access roads. When planning for solar orientation,
there may be trade-offs to address these and other considerations.

3-30 Passive solar design, basic features installed


5 POINTS

Basic features include east/west orientation, optimal glazing, and properly sized overhangs. These strategies will
prevent excessive solar gains in the summer while allowing the sun to enter the home during the heating season.

76
A: The overhang is optimized to limit solar gains
during the cooling season without limiting the solar
gains in the winter.

B: This dimension optimizes the glazing access to


solar heat gains during the heating season. Glazing
placed in this area will not receive direct solar gains
and will not contribute to solar heating.

C: All other functions are based on the vertical


dimension of the glazing.

B + C: Glazing placed below this dimension will not be


shaded in the summer. This will result in solar gains
during the summer months.

Effectiveness of the shading diminishes if the building


orientation changes. Within 30 degrees of due south,
this formula will provide relatively good results. East
and West facing glazing require shading by other
means such as exterior blinds, or landscaping.

Figure 3-9 Overhangs


(Source: Washington State University Cooperative Extension Energy Program)

Resources
See diagram in Part I for this Action item.

• Turn to Solar for Lower Heating Costs, Energy Source Builder #42, December 1995, IRIS Communications,
Eugene, OR, www.oikos.com/esb/42/solar.html. Provides good general background information.
• Sun Angle shareware program, susdesign.com/sunangle. Allows you to find solar angles at any time of
day; a useful tool for locating and sizing overhangs.
See Resources, Solar, above.

3-31 Passive solar design, advanced features installed


1-12 POINTS

Advanced passive solar is performance based. It is best to document a reduction in total space conditioning for
heating and cooling. Then, demonstrate how the home will stay within reasonable temperature range.

77
If you choose not to demonstrate the total reduction in space conditioning energy, consider that passive solar
designs from the 1970’s do not work contemporary glazing products. Also, combining passive solar design with
advanced framing, see Action item 3-23, Use Advanced Wall Framing, is a good idea, but may require adjusting
solar techniques to work with the tightness of this framing system.

Advanced passive solar design features may include orienting windows to maximize passive solar, designing
thermal mass correctly to correlate with window design, and providing East and West Shading.

To make the best use of passive solar, orient the majority of the buiding’s glazing within 22 degrees of due South.
Due South can be located with a simple compass. Remember to make the correction for magnetic North, which is
21 to 22 degrees East in the Puget Sound area. Obviously, this assumes there will be windows on the south side;
for solar heating benefit, these should not be obstructed in winter. To prevent overheating, window glass on the
south side of the building should not exceed 8% of the floor area. However, window area can be increased
significantly (and solar performance enhanced) if there is accessible thermal mass in the space to absorb excess
heat. Building components that can add mass to the home include concrete floors, tile, extra drywall, and to some
extent, wood flooring. Consider the installation of skylights in a south-facing roof. Install with blinds to control the
heat.

Use glazing with Solar Heat Gain Coefficient less than 0.40 or provide natural shading with landscaping. East and
west shading strategies help protect against overheating the home. The most shading is provided by means of
exterior shading devices, especially trees and other natural landscaping. They block the heat before it gets to the
window. In addition, windows made using specially coated or tinted glazing reduce the window’s solar heat gain
coefficient (SHGC). They block the heat gain without rejecting too much visible light. For comparison, standard
clear glass has a SHGC of 0.85. Special coatings/tinting can produce windows with SHGC down to 0.38, depending
upon the treatment. These can be especially useful if the home has an attractive view to the West.

Resources
See Solar listing in General Resources above.

Efficient Windows Collaborative, www.efficientwindows.org, provides general but useful information for selecting
windows for different types of climates and orientations. Also see resources for Action item 2-39 Species and
locations for tree planting are identified that will provide summer shading of the dwelling and parking areas to
moderate temperatures.

3-32 Model solar design features using approved modeling software


3 POINTS

Gaining experience by using approved modeling software allows you to determine the effectiveness of
incorporating these strategies into your project. See the Resources Section for a list of approved modeling
software or consult the Program Director.

Resources
See Software above under General Resources, for approved modeling software for Washington State code.

3-33 Design and implement passive cooling system (no A/C; radiant cooling or passive
cooling system)
5 POINTS

The best option is to initially design the home to make the best use of natural ventilation and passive cooling
techniques. See Action items 3-31 and 3-31, on Passive Solar Design, and 3-35, Two Properly Supported Ceiling Fan
Pre-Wires.

78
An operable skylight can be used to create controlled natural ventilation, allowing warm air that has risen to the
top of the house to escape, and drawing up cool air from below. However, skylights can be a source of unwanted
solar heat gain and/or thermal loss, so location should be carefully selected, and the benefits weighed against the
disadvantages.

By employing passive cooling techniques into modern buildings, you can eliminate mechanical cooling or at least
reduce the size and cost of the equipment. Passive cooling, which is based on the interaction of the building and
its surroundings, can eliminate or at least partially offset the need for mechanical cooling in the project. The four
major passive cooling strategies include:

Natural ventilation depends solely on air movement to cool occupants. Window openings on opposite sides of
the building enhance cross ventilation driven by breezes, as do openings in tall spaces (stacks) in building ceilings.
With openings near the top of the stack, warm air can escape, while cooler air enters the building fromopenings
near the ground. Ventilation requires the building to be open during the day to allow air flow. While operable
skylights can be used to control natural ventilation, they can also be a source of unwanted solar heat gain and
thermal loss. If skylights are used, locations must be considered carefully.

High thermal mass depends on the ability of materials in the building to absorb heat during the day. Each night
the mass releases heat, making it ready to absorb heat again the next day.

High thermal mass with night ventilation relies on the daily heat storage of thermal mass combined with night
ventilation that cools the mass. The building must be closed during the day and opened at night to flush the heat
away.

Evaporative cooling lowers the indoor air temperature by evaporating water. In dry climates, this is commonly
done directly in the space. But indirect methods, such as roof ponds, allow evaporative cooling to be used in more
temperate climates too.

Any skylight or clerestories used for this Action item must be operable, and have a U-factor smaller or equal to .45
& Solar Heat Gain Coefficient smaller or equal to .35.

Before adopting a passive cooling strategy, you must be sure that it matches & responds to specific site climate
conditions.

Resources
• U.S. Department of Energy, Energy Efficiency and Renewable Energy, website offers links to many
documents on energy efficiency, including information on skylights, www.eere.energy.gov.
• Build It Solar offers numerous solar techniques, including passive cooling techniques.
http://www.builditsolar.com/Projects/Cooling/passive_cooling.htm

HEATING/COOLING SYSTEM
Equipment & Distribution
Heat loss from the average ducted air distribution system can reduce the overall system efficiency by 30%.
Reducing duct air leakage and improving duct insulation has potential to significantly reduce utility bills and
prevent or eliminate associated comfort and health problems. Specifically:

• Heating and cooling costs can be reduced by as much as 20-30%.


• Comfort can be improved by ensuring adequate delivery and return of conditioned air.
• Downsizing of heating and cooling equipment is possible.
• Entry of mold, radon, dust, and moisture into the house can be reduced.
At the beginning of a project, give consideration to:

• Location of the duct work.

79
• Duct type and size.
• Sealing method.
• Insulation method, R-value.
• Providing equal cross-sectional area for supply and return duct openings, and eliminating
non-communicating ducts. (Each supply duct needs to “see” a return duct, and visa-versa. If there is a door
between them, a transfer duct is required.)
As discussed below, it is preferable to locate ducts within the building envelope. However, this option is not
always possible, even with new construction. In this case, ducts should be sealed with mastic and better perhaps
insulated (See Action item 3-38, Use Advanced Sealing of All Ducts Using Low Toxic Mastic).

3-34 Centrally locate heating/cooling system to reduce the size of the distribution
system
1 POINT

Locating the furnace in a central, well-insulated mechanical closet can save energy by reducing delivery distance
and heat loss. (It can also conserve material use by requiring less ducting.) Make sure you provide sufficient
make-up air.

3-35 Provide two properly supported ceiling fan pre-wires


1 POINT

Provide wiring and switching needed for a ceiling fan in the original electrical plan. If installed, a ceiling fan can be
used as a low-energy option to provide cooling on hot summer days.

3-36 Install properly supported ENERGY STAR ceiling fans


1 POINT PER FAN
2 POINTS MAXIMUM

A ceiling fan can be used as a low-energy option to provide cooling on hot summer days. Must install an ENERGY
STAR Fan and accessible switching.

3-37 Use foil-covered external insulation on metal ducting


1 POINT

3-38 Use advanced sealing of all duct joints using low-toxic mastic
1 POINT

Efficiency of the heating distribution system can be improved by 15% if the ducts located in the crawlspace or
attic are sealed better than standard practice. Using mastic to seal commonly used fittings or using improved duct
fittings with gaskets reduce the air leakage rate of the heating system and the structure as a whole. Additional
benefits may include improved comfort by reducing drafts, improved occupant control of the distribution of heat
to individual rooms, and a reduction of dirt introduced into the home.

The cost for this measure will vary depending upon the HVAC contractor and the system. Be sure to obtain
individual system bids from the HVAC contractor you will use.

80
Note: The home needs to be pressure balanced with the goal of reducing backdrafts. If the furnace return is
adjacent to a combustion appliance it will backdraft even with a perfectly airtight duct system.

Use this sealing technique for Heating Recovery Ventilation Systems; see Action item 3-50, Install Heat Recovery
Ventilator.

Resources
Local sources for low toxic duct mastics include:

• Hardcast Versa Grip Mastic, Gensco, Tacoma, WA, 253-620-8203, www.gensco.com. Many northwest
distributors.
• Hardcast Versa Grip Mastic for RCD Mastic, Albina Wholesale, 888-639-3330, www.albina.com/whsl/

3-39 Third-party duct test results less than 4% loss of conditioned floor area (50
pascals)
2 POINTS

To qualify for this credit, the results of the duct test performed by a third-party must be less than 4% loss of floor
area to outside/total flow, e.g., a 1,000 square foot house should have less than 40 cfm of leakage in the ductwork.
If the ductwork is sealed tightly with mastic and other moderate sealing efforts are employed it should at least
pass at level of duct tightness of 4-5% of the floor area. See Air Sealing sub-section above for ideas on how to
maximize air sealing to achieve this credit. Additionally, consider that achieving this result could be difficult in a
large structure, see prerequisites, Conform to House Size Matrix.

Resources
• To locate ENERGY STAR Builder Option Package Verifiers, go to http://www.energystar.gov/. Verifiers are
listed as Home Energy Raters on the New Home Partner Locator Search Page
(http://www.energystar.gov/index.cfm?fuseaction=new_homes_partners.showHomesSearch).
For general information, see the article, “Pipe Dreams,” in Northwest Energy Efficiency Alliance Newsletter, Volume
3, Issue 1 (Winter 1999), Northwest Energy Efficiency Alliance, 800-411-0834,
www.nwalliance.org/news/newsletters/neeaWinter99.pdf.

For information about Performance Tested Comfort Systems air leakage testing/criteria, contact a certified
contractor or call the WSU Cooperative Extension Energy Program, 360-956-2000,
www.energy.wsu.edu/buildings.

3-40 Place all ducts in conditioned space


3 POINTS

A heating system’s efficiency can be improved by 30% or better if the entire heating system is located within the
conditioned space. Points are warded for this Action item, ONLY if ALL ducts are in the conditioned space – see
the next Action item to get points for partial inclusion.

Besides adding energy efficiency, this practice also reduces moisture problems and can also reduce dust and other
indoor air quality problems.

Strategies to consider include: constructing bulkheads, dropped soffits, tray ceilings, running ducts through open-
web floor joints, and placing ducts in closets, conditioned crawlspaces, and attics.

Incorporating all ducts in the conditioned space may cost slightly more than conventional methods, however,
costs can potentially be offset by reducing the size of the equipment, eliminating duct insulation, minimizing duct
length, and reducing overall material costs.

81
Resources
• “Ducts in Conditioned Space” from the ToolBase TechSpecs of The Partnership for Advancing Technology
in Housing (PATH), available online at
www.toolbase.org/pdf/techinv/ductsinconditionedspace_techspec.pdf /.

3-41 Insulate any ducts located in unconditioned space to at least R-11


1 POINT

Un-insulated ducts in the crawl space can actually increase energy use in the home, lead to increases in crawl space
moisture, and cause frozen water pipes. To avoid these problems insulate all ducts to at least R-11. See Action
item 3-42, Locate Heating/Cooling Equipment Inside the Heated Space and Action item 3-40, Locate All Ducts Inside
the Conditioned Space).

3-42 Locate heating/cooling equipment inside the conditioned space


5 POINTS

As noted above, a heating system’s efficiency can be improved by 30% or better if the entire heating system is
located within the heated space. In many cases this will be a no-cost measure. For forced air heating systems,
moving the ducts inside usually increases the cost of framing and drywall. But the HVAC bid will be lower,
off-setting these costs. Even if the total cost increases some, the energy savings will more than pay for the change
in construction details. Carefully planned hydronic systems or in-space heating systems will also provide these
benefits.

• Forced Air Systems: Locate most ducts inside heated space; ducts outside heated space to be insulated to
R-11
• Hydronic Systems: Locate most components inside the heated space.

Resources
• “Ducts in Conditioned Space” from the ToolBase TechSpecs of The Partnership for Advancing Technology
in Housing (PATH), available online at
www.toolbase.org/pdf/techinv/ductsinconditionedspace_techspec.pdf /.

3-43 Air handling equipment or return ducts are not located in the garage, unless
placed in isolated/air sealed mechanical rooms with an outside air source
3 POINTS

3-44 Design the distribution system using ACCA Manual D


2 POINTS

3-45 Use ductless distribution system (e.g. hydronic, radiant, ductless minisplits)
10 POINTS

82
A ductless distribution system is generally more efficient than a system that utilizes ducts. Ductless systems also
have the added benefit of better indoor air quality. Ductless systems allow for easy installation, less maintenance,
quiet operation, more efficiency, and zone control. Air leakage in forced air heating systems frequently impact
indoor air quality. Duct leaks bring air into the building from undesirable locations, such as attics, crawl spaces,
and the garage. Duct leaks can also induce combustion equipment backdrafting. These problems will not exist at
all if a ductless heating system is used, such as a ductless electric heat pump or radiant floor system.

To receive credit equipment must meet the following guidelines:

• Hydronic Systems 85% Efficiency or better


• Ductless Split Heat Pump 10.0 HSPF Minimum (Single indoor fan coil)
• Ductless Split Heat Pump 8.5 HSPF Minimum (2 or more indoor fan coils)
Note: Standalone zonal electric baseboards to not count for this credit. In addition, please note currently
Washington state regulations prohibit the install of an outdoor wood fired boiler.

3-46 Where appropriate, install furnace fan or pumps with an electrically commutated
motor (ECM)
3 POINTS

An ECM motor will reduce motor energy use by about 331 kWh per year. However, because the motor gives off
waste energy as heat to the home, the energy it is not truly lost during the heating season, and financial savings
are about half what might otherwise be expected. If used with an air conditioner, however, the electrical energy
savings could double. For these reasons, consider an ECM motor when installing heating or cooling equipment.

Note: The most appropriate use of an ECM is on equipment specifically designed to take advantage of the motors
part load capability. This is most commonly found on high quality heat pump systems with variable speed fan
controls and some variable speed gas furnaces.

3-47 Locate registars towards center of home rather than at outside walls minimizing
ducting and loads on unit
1 POINT

Controls

3-48 Select high-efficiency heat pumps instead of electric heat (add, or heat pump
with efficiency that exceeds code requirements
3 POINTS
NOT APPLICABLE IF CLAIMING UNDER WSEC TABLE 406.2

Most heat pumps act by transferring heat from an environmental source, air, water or ground, into the dwelling. A
new type of heat pump is the absorption heat pump that uses heat as the energy source. These systems offer an
energy-efficient alternative to furnaces and air conditioners. In fact, high-efficiency heat pumps also dehumidify
better than standard central air conditioners, resulting in less energy usage and more cooling comfort in summer
months, according to the Department of Energy. All of these varieties are suitable to our climate.

Air-source heat pumps are the most common and are available in a ductless version, called a mini-split system.
Geothermal (ground-source or water-source) systems provide higher efficiencies, however, they cost more to
install and has some site-specific limitations. See Action item, 3-55, Install Geothermal Heat Pumps.

83
To select the highest efficiency heat pump, look for the Energy Guide label. Heating efficiencies are rated
according the heating season performance factor (HSPF) and the cooling efficiency is determined by the seasonal
energy efficiency ration (SEER). High efficiency pumps will have a HSPF between 8 and 10, and a SEER between
14 and 18. In our climate focus should be on getting the highest HSPF possible.

Finally, as with any system, performance is affected by leaky ducts. Be sure to maintain 400-500 cfm airflow for
each tone of the heat pump’s air-conditioning capacity. Efficiency and performance deteriorate if airflow is less
than 350 cfm per ton. To ensure optimum functioning, be sure to include appropriate servicing information in the
Operations & Maintenance Kit that is part of Section 1.

Resources
Heat Pump Systems, by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy
provides more information on these specific types of heat pumps
(www.eere.energy.gov/consumer/your_home/space_heating_cooling/index.cfm/mytopic=12610):

• Air-Source Heat Pumps


• Ductless Mini-Split Heat Pumps
• Geothermal Heat Pumps
• Absorption Heat Pumps.
American Council for an Energy-Efficient Economy, Consumer Guide, The Most Energy-Efficient Conventional (Air-
Source) Heat Pumps, good general information http://www.aceee.org/consumerguide/topfurn.htm. Plus link to
The Most Efficient Conventional (Air-Source) Heat Pumps, http://www.aceee.org/consumerguide/hp.pdf, revised
2005.

3-49 Install a heating system with zonal controls


5 POINTS

This credit is awarded for installing a zoned heating system, not for programmable thermostats.

Use any heating system that allows for separate zones, see Action items 3-45, Use Ductless Distribution System
(e.g. Hydronic, Radiant, Ductless Minisplits).

Heat Recovery

3-50 Install a heat recovery ventilator (HRV) or energy recovery ventilator (ERV)
5 POINTS
NOT APPLICABLE IF CLAIMING UNDER WSEC TABLE 406.2

A heat recovery ventilator (HRV), also known as an air-to-air heat exchanger (AAHX), provides an energy efficient
and effective ventilation system that cannot be matched by exhaust-only ventilation systems commonly used in
houses. With these units, waste sensible heat (the energy responsible for raising or lowering temperature) in the
exhaust air stream is transferred by a heat exchanger into the incoming air stream, significantly reducing the
energy required to heat cold outdoor air to interior comfort levels. These units are able to recover 50% to 80% of
the heat energy that would otherwise be lost through ventilation. Even in Western Washington’s mild climate,
these energy savings pay for the HRV long before the equipment reaches its rated service life.

An energy recovery ventilator (ERV) has the same basic function as an HRV, except that in addition to transferring
sensible heat, it also transfers latent heat (the energy responsible for changing the moisture level). This makes an
ERV a good option in warm and humid climates. Learn more about which system will work for your project,
HTTP://ENERGY.GOV/ENERGYSAVER/ARTICLES/WHOLE-HOUSE-VENTILATION

84
Another advantage of an HRV or ERV system is that it provides high quality ventilation to the house for
maintaining indoor air quality (see Action item 4-80, Bonus Points: Provide Balanced or Slightly Positive Indoor
Pressure Using Controlled Ventilation).

Resources
For information about air exchangers or other ventilation systems, contact your mechanical subcontractor or:

• “Energy Ideas Clearinghouse.” EIC will provide customized responses to specific questions about
ventilation, 800-872-3568 or e-mail EnergyLine@energy.wsu.edu. Or you can browse for resources
yourself online at www.energyideas.org (listed under General Resources, above).
• Healthy House Building: A Design and Construction Guide, by John Bower, The Healthy House Institute,
Unionville, IN. (Good information on optimizing air distribution and ventilation.) . Available from Iris
Communications, 800-346-0104 or www.oikos.com (Item # 7503, $22).
• Understanding Ventilation: How to Design, Select, and Install Residential Ventilation Systems, by John
Bower. Available from the Journal of Light Construction Bookstore: 800-859-3669 or
www.jlconline.com/bookstore.
• “Energy and Heat Recovery Ventilators (ERV/HRV)” from the ToolBase TechSpecs by The Partnership for
Advancing Technology in Housing (PATH), www.toolbase.org/Technology-Inventory/HVAC/energy-
recovery-ventilators.
HRV and ERV manufacturers include:

• Aldes compact heat recovery ventilators, from American Aldes Ventilation Corporation, Sarasota, FL, 941-
351-3441, www.americanaldes.com.
• Guardian, by Broan Mfg. Company, Hartford, WI, 800-368-8663, www.broan.com.
• PerfectAire, by Research Products Corp., Madison, WI, 800-334-6011, www.resprod.com.
• Perfect Window fresh air ventilation system, by Honeywell Corporation, Minneapolis, MN, 800-345-6770 or
www.honeywell.com.
• VanEE, by Conservation Energy Systems, Saskatoon, Saskatchewan, Canada, 800-667-3717.

Heating / Cooling

3-51 Select ENERGY STAR heating/cooling equipment


5 POINTS
NOT APPLICABLE IF CLAIMING UNDER WSEC TABLE 406.2

By selecting ENERGY STAR rated heating and cooling equipment you are assured of significant energy savings. The
upgrade encompasses many different types of equipment, including 90% AFUE furnaces, 7.4 HSPF heat pumps,
and ground source heat pumps.

The Energy Policy Act of 2005 provides a federal income tax credit to consumers who purchase Energy Star
qualifying products; you can use these as guidelines:

• Furnaces: 95% AFUE or greater


• Boilers: 95% AFUE of greater
• Electrically Efficient Gas- and Oil-Fired Furnaces
• Gas and Oil-Fired Water Heaters: 80 EF or greater
• Electric Heat Pump Water Heaters: : 2.0 EF or greater

85
Resources
• The EPA lists online products that currently qualify for the ENERGY STAR label and a store locator, see
http://www.energystar.gov. Or e-mail labeling@energystar.gov or call the ENERGY STAR hotline at 1-
888-STAR-YES.

3-52 Install high-efficiency auxiliary heating units, e.g. EPA-approved pellet stove,
russian fireplace, masonry radiant heater
2 POINTS

Wood or coal-burning stoves and fireplaces can be troublesome if not completely sealed. Even if a fuel-burning
device is connected to a chimney, pollutants can enter the home through spillage, backdrafting (whenever there is
even a slightly negative air pressure in the house), or due to lack of maintenance or damage to the chimney.

3-53 Properly size HVAC system using ACCA Manual J (do not oversize)
2 POINTS

TO RECEIVE POINTS FOR THIS CREDIT, CONTRACTORS SHOULD SUBMIT LOAD CALCULATIONS AND SHOW
INVOICES FOR EQUIPMENT OF PROPER SIZE.

The benefits of properly sizing HVAC systems include satisfied and comfortable customers, lower initial and
operating costs, reduced callbacks, longer equipment run times and less cycling, and proper dehumidification
during the cooling season. Yet, many contractors regularly oversize air conditioning units. All HVAC equipment
must be sized per manual J, ARI standards and guidelines. This equipment must be installed with matching
Thermal Expansion Valve or (TXV). Manual J, which provides guidelines for estimating and calculating HVAC
loads, has a substantial over sizing margin which can encourage significant over sizing of units.

To properly size HVAC systems, air infiltration measurements must be estimated unless a blower door test is
performed (see Action item 3-16. The calculation outlined in Manual J (which is published by the Air Conditioning
Contractors of America (ACCA), estimates heat loss from the building through walls and ceilings, leaky ductwork,
and infiltration through windows, doors, and other penetrations as well as heat gain into the building from
sunlight, people, lights and appliances, doors, walls, and windows, and infiltration though wall penetrations. To
account for Manual J’s large over sizing margin, this credit requires a maximum over sizing of less than 15% of that
margin.

The efficiency of central air conditioning units is governed by U.S. law and regulated by the U.S. Department of
Energy (DOE). Every air conditioning unit is assigned an efficiency rating known as its “seasonal energy efficiency
ratio” (SEER), which is determined by its total cooling output divided by its total energy consumption. The more
efficient the air conditioning equipment, the higher the SEER rating, and the less expensive it is to operate. All
central air conditioners manufactured in the United States after January 23, 2006 must meet the new federal
minimum 13 SEER/EER rating, a 30 percent increase from the current minimum standard.

All air conditioners include an indoor (coil) unit and an outdoor (condensing) unit, which work together to
maximize efficiency and comfort. Proper matching of the coil and condenser will result in higher efficiency.

The standard thermal expansion valve (TXV) is a dynamic valve that has three main functions: to provide a
constant amount of evaporator superheat, to keep the entire evaporator full of liquid/vapor, and to prevent liquid
refrigerant from going back into the compressor. It also helps the air conditioner operate at maximum efficiency.

3-54 Use direct vent gas or propane hearth products (AFUE rating)
2 POINTS

86
Combustion appliances in general can be troublesome if not completely sealed. They can inadvertently admit
noxious gases such as carbon monoxide into the air. Even if a fuel-burning device is connected to a chimney,
pollutants can enter the house through spillage, backdrafting (whenever there is even a slightly negative air
pressure in the house), or due to lack of maintenance or damage to the chimney.

3-55 Install geothermal heat pumps


10 POINTS
NOT APPLICABLE IF CLAIMING UNDER WSEC TABLE 406.2

As mentioned above in Action item, 3-48, Select High Efficiency Heat Pumps Instead of Electric Heat geothermal
(ground-source or water-source) systems provide higher efficiencies, however, they cost more to install and has
some site-specific limitations.

Geothermal systems use the ground instead of outside air to provide heating, cooling, and in most cases, hot
water. Using the ground ‘s relatively constant temperature as the exchange medium for these systems, results in
the most efficient system that is best at producing comfortable heating and cooling.

Conventional ductwork is generally used with these systems. Many systems are being equipped with a separate
heat exchanger to meet of the a household’s hot water needs, particularly when the system is not operating,
typically in the spring and fall.

As to site-specific limitations, installation can be impacted by lot size, the condition of the subsoil, and the
landscape, which in turn can affect the applicability of this system to a particular site.

Resources
The Geothermal Technologies Program, www1.eere.energy.gov/geothermal, by the U.S. Department of Energy's
Office of Energy Efficiency and Renewable Energy, provides more information, including

• "Geothermal Heat Pumps" by U.S. Department of Energy's Office of Energy Efficiency and Renewable
Energy, www1.eere.energy.gov/geothermal/heatpumps.html.
Other information available:

• "Geothermal Heat Pumps" from A Consumer’s Guide to Energy Efficiency and Renewable Energy by DOE’s
EERE, www.eere.energy.gov/consumer/your_home/space_heating_cooling/index.cfm/mytopic=12640
• “Geothermal Heat Pumps” by ENERGY STAR,
www.energystar.gov/index.cfm?c=geo_heat.pr_geo_heat_pumps.

WATER HEATING

Resources
• Consumer Guide to Home Energy Savings, by Alex Wilson and John Morrill, is updated annually (See General
th
Resources above). For the water heaters that the 7 Edition lists as “Top-Rated Energy-Efficient,” see
www.aceee.org/consumerguide/topwater.htm.

Distribution

3-56 Locate water heater within 20 pipe feet of highest use


1 POINT

Locating the hot water heater near the point of highest use will minimize pipeline energy loss. Typically, the point
of highest demand is the shower.
87
3-57 Insulate all hot water pipes
1 POINT

This measure reduces standby heat loss from the water tank. The tank continuously heats the piping and the
water in it even when no water is being used. They act as “cooling rods.” Insulating them reduces the rate of heat
loss.

3-58 Design home with single plumbing wall


3 POINTS

3-59 Use 3/8" pipe (PEX) tubing


2 POINTS

3-60 Install an on demand hot water recirculation system


1 POINT

Drainwater Heat Recovery

3-61 Install drainwater heat recovery system (DHR)


3 POINTS

A significant amount of energy is lost when draining warm wastewater. Drainwater heat recovery (DHR) devices
fit into existing drain lines to capture some of that exiting energy. DHR systems use drainwater to preheat cold
water going to a shower or to a water heater. DHR systems reduce the energy needed to heat water and can
increase the capacity of water heaters.

DHR systems cost between $300 and $500, plus installation.

88
From EERE, from Toolbase Services
For these to work, the drain and water heater needs to be under the primary shower. The water demand and drain
use need to occur simultaneously.

Resources
Drainwater heat recovery systems are available from:

• Doucette Industries, Inc., York, PA, 800-445-7511, www.doucetteindustries.com.


• Earthstar Energy Systems, Waldoboro, ME, 207-832-6861.
• TR Strong Building Systems, Olympia, WA, 360-705-2868, www.baubuilder.com.
• Vaughn Manufacturing Corporation, Salisbury, MA, 800-282-8446 or www.vaughncorp.com/ .
• “GFX Wastewater Heat Reclaimer in Contention,” Environmental Building News Volume 8, No. 9,
September 1999, and “Recovering Heat from Wastewater,” Environmental Building News Volume 6, No. 8,
September 1997. Available online at www.buildinggreen.com/products/gfx.html.
See also the NAHB Research Center’s ToolBase TechSpecs on Drainwater Heat Recovery, available online at:
www.toolbase.org/Technology-Inventory/Plumbing/drainwater-heat-recovery.

"Drain-Water Heat Recovery" from A Consumer’s Guide to Energy Efficiency and Renewable Energy by DOE’s
EERE, www.eere.energy.gov/consumer/your_home/water_heating/index.cfm/mytopic=13040.

Water Heating
Water heating typically accounts for 15 to 25% of the energy used in a home. Consequently, improvements in
water heating efficiency offer good opportunities to save resources and money. Fuels with greater heating value
include natural gas, propane, and fuel oil.

The water heating improvements listed below are based on the water heater being located inside the conditioned
space of the home. Water heaters located in the garage or other interior spaces are likely to save more. These
upgrades are commonly available in 40-gallon and 50-gallon units.

3-62 Install tankless water heater

89
2 POINTS
NOT APPLICABLE IF CLAIMING UNDER WSEC TABLE 406.2

See Action item 3-60, Install an on demand hot water recirculation system, for additional information.

With instant or demand or “tankless” water heaters, you only heat the water you use. Instead of storing hot water
in an insulated tank, the water is heated, on demand, at the point of use. These systems can save as much as 3 to
4 gallons per use, considering that this is the amount of cooled water that must be drained before hot water
arrives at the faucet in traditional systems. In addition, standby energy losses represent 10% to 20% of a
household’s annual water heating costs.

In the past, instant hot water systems were either electric (converting only a third of the primary energy into
usable thermal energy), or if they were gas fired, they were equipped with continuously burning pilot lights that
wasted energy. Newer, gas-fired models without continuously burning pilot lights are available. Such systems
save water and energy, providing even more bang for the buck.

Resources
Energy Guide labels are not required on demand-type water heaters. For an evaluation of their energy-conserving
features, see the Consumer Guide to Home Energy Savings, by Alex Wilson and John Morrill, pp. 146-147, 160-164
(listed under Action item 6-1, A building owners’ manual is provided.)

• See fact sheet on demand (tankless) water heaters by the US Department of Energy, Energy Efficiency
and Renewable Energy Network (EREN) at www.eren.doe.gov/consumerinfo/refbriefs/bc1.html.
Manufacturers include:

• Rinnai America, LaGrange, GA, 800-621-9419 or www.rinnaiamerica.com. The Rinnai Continuum 2424
designed for exterior mounting, which keeps all combustion outdoors, eliminating risk of combustion gas
spillage and saving valuable indoor space. It is one of the few gas-fired demand water heaters with
electronic ignition instead of a pilot light, one of the features that enables it to achieve its high 82% AFUE
efficiency. See “New Demand Water Heater from Rinnai,” Environmental Building News, Volume 9,
Number 2, February 2000. (Environmental Building News, Brattleboro, VT, 802-257-7300,
www.buildinggreen.com.)
AquaStar, distributed in the U.S. by Controlled Energy Corporation (CEC) of Waitsfield, Vermont.
• The AquaStar 125-EI demand water heater has a pilot light, but it is usually unlit. When hot water is called
for, two integral D-cell batteries ignite the pilot, which in turn ignites the water heater burner. It uses just a
tiny amount of electricity, as evidenced by the two D-cell batteries, and is almost instantaneous, according
to CEC marketing vice president Kyle Murray. Contact R. Kyle Murray, Controlled Energy Corporation,
800-642-3111 or www.cechot.com. See “A New Generation of Demand Water Heaters,” Environmental
Building News, Volume 7, No. 4, April 1998 and “An Update on Demand Water Heaters,” Environmental
Building News, Volume 8, No. 2, February 1999. (Environmental Building News, Brattleboro, VT, 802-257-
7300, www.buildinggreen.com.)
• Low Energy Systems (distributor of various demand water heaters), Englewood, CO, 303-781-9437,
palomawaterheaters.com.
Other manufacturers are listed in GreenSpec and the REDI Guide.

3-63 Install electric water heater efficiency to EF of 0.93 or higher


NOT APPLICABLE IF CLAIMING UNDER WSEC TABLE 406.2
3 POINTS

Be careful to avoid heat loss (through heat traps) when you have a hot water tank on lower floors feeding upper
stories.

90
3-64 Upgrade gas or propane water heater efficiency to EF 0.62, 0.83, or 0.90
NOT APPLICABLE IF CLAIMING UNDER WSEC TABLE 406.2

1 POINT FOR EF 0.62


3 POINTS FOR EF 0.83
5 POINTS FOR EF 0.90

A heater's efficiency is rated by the Energy Factor (EF), which is based on recovery efficiency (i.e., how efficiently
the heat from the energy source is transferred to the water), standby losses (i.e., the percentage of heat lost per
hour from the stored water compared to the heat content of the water), and cycling losses. The higher the EF, the
more efficient the water heater. Typically, gas storage tank water heaters have an EF between 0.55 and 0.67, 0.58
is typical. Gas tankless systems range from 0.69 to .92, with 0.84 typical. Some high-efficiency models are
designed to use propane, which may be up to 30 percent less expensive to operate than electric heaters.

Current code requires domestic hot water systems meet the requirements of the 1987 National Appliance Energy
Conservation Act (NAECA). Upgrading gas water heater efficiency from an EF of .55 to .60, for instance will save
18 therms per year. Household operational savings will support an additional cost of about $38. Upgrading a
propane water heater from an EF of .55 to .60 will save 16 gallons of propane per year. Household operational
savings will support an additional cost of about $50. Be careful to avoid heat loss (through heat traps) when you
have a hot water tank on lower floors feeding upper stories.

Resources
The best source for efficiency information for water heaters is the GAMA (Gas Appliance Manufacturers
Association) guide. 703-525-7060, www.gamanet.org. GAMA will answer questions on residential gas appliances
and equipment, and electric and oil-fired water heaters.

• How to Buy an Energy-Efficient Gas Water Heater, US Department of Energy, FEMP. Available online at
www.eren.doe.gov/femp/procurement/gwh.pdf, A publication of the Federal Emergency Management
Program, this two-page fact sheet is primarily for federal agencies, but provides good general information
for residential builders as well.
See also:

• "Conventional Water Heating Efficiency" by U.S. Department of Energy's Office of Energy Efficiency and
Renewable Energy, Building Technologies Program,
www.eere.energy.gov/buildings/info/components/waterheating/conventional.html.
• “Consumer Guide to Home Energy Savings – Water Heating” by American Council for an Energy-Efficient
Economy, http://www.aceee.org/consumerguide/topwater.htm.

3-65 Install water heater inside the heated space (electric, direct vent, or sealed
venting only)
2 POINTS

By installing the water heater inside the heated space, you minimize heat loss to the environment.

Combustion water heaters located inside the living area must be sealed combustion type. They will have outside
combustion air ducted to the firebox. They also must be directly vented to the outside with no possibility of
combustion products mixing with indoor air.

Direct vent hot water heaters help protect indoor air quality by venting combustion by-products outside. They
also draw combustion air from outside instead of using treated indoor air.

91
3-66 Upgrade electric water heater to exhaust air heat pump water heater or de-
superheater: EF 2.0
6 POINTS
NOT APPLICABLE IF CLAIMING UNDER WSEC TABLE 406.2

The exhaust air heat pump is a good option for families who require lots of hot water. A unit with an EF of 2.0 will
yield 50% savings in energy use compared to a conventional system.

Resources
Talk to your plumbing contractor and see products and manufacturers listed in GreenSpec and the REDI Guide.

3-67 Use indirect water heater for domestic hot water (DHW)
2 POINTS

LIGHTING
Lighting accounts for 5 to 10% of total energy use in U.S. homes, costing $50 to $150 directly per year. While this
amount is relatively small, lighting choices can also affect the amount of energy used to heat and cool the home.
More efficient lighting can also mean better lighting, such as when daylighting and task lighting is specifically
considered as part of the design.

Natural Light

3-68 Light-colored interior finishes


1 POINT

Light colored interior finishes naturally reflect both natural and artificial light, reducing the demand for additional
artificial lighting.

3-69 Use clerestory for natural lighting


2 POINTS

Careful design and specification of windows is a cost-effective way to save energy. Further savings are achieved
by shading techniques and north-facing clerestory windows (any window with sill above eye level) that admit
natural light without direct solar gain.

3-70 Use light tubes for natural lighting and to reduce electric lighting
2 POINTS

Well-placed windows, small skylights, and light-colored surfaces can make for a sunny, cheerful, inviting interior
while saving energy. Light tubes are a new type of “skylight” on the market. These devices are tested to be very
effective at transmitting light, generally do not suffer condensation problems, and when compared to
conventional skylights, allow less heat loss during winter and less solar heat gain in summer. They also provide
significant location flexibility and are fairly easy to install. Basic components include a clear plastic dome on the
roof that admits sunlight; a reflective tube that carries light down into the home; and a ceiling-mounted light
diffuser that distributes light into the target room. Also available are light tube options with a vent (for bath) or
recessed can (for illumination at night).

92
Resources
Your local supplier can probably source these products for you. Some light tubes to consider are:

• Solatube, distributed by Northwest Natural Lighting, Lynnwood, WA, 800-773-SOLA (800-773-7652) or


www.solatube.com.
• Sun Pipe, first light pipe sold for homes in North America. Sunpipe Co., Northbrook, IL, 800-844-4786,
www.sunpipe.com.
• EZ Light, manufactured and distributed by “odl” Inc, Zeeland, MI, 800-288-1800.
• Sun Tunnel with flexible tubing, distributed by The Sun Tunnel Skylights, 800-369-3664 or
www.suntunnel.com.

3-71 Create more shared light with glass interior doors and windows
1 POINT

Efficient Lighting

3-72 Solar-powered walkway or outdoor area lighting


1 POINT

Solar powered outdoor lighting uses a photovoltaic (PV) panel to generate electricity during the daytime, which is
then stored in a battery. At night, that stored electricity is used to power the light. Some models are manual, while
others are turned on automatically by light-sensing controls or activated by motion-sensing devices. Most of
these walkway or security lights require no wiring or installation other than pushing the stake into the ground, or
screwing the fixture to a garage wall.

Most of the widely marketed solar walkway lights do not put out a lot of light, but they are useful for lighting the
path to the door so guests can find their way. Also available are larger solar lights that do provide a lot of light, but
these can be expensive.

Solar-powered outdoor lights can be found in many hardware or department stores, or purchased through catalog
retailers of alternative energy and stand-alone power equipment.

Resources
• Outdoor Lighting Pattern Book, by Lighting Research Center. Available from Iris Communications, Eugene,
OR, 800-346-0104 or www.oikos.com (Item #7562, $50.00).

3-73 Use compact fluorescent bulbs, ballast, or fixtures in three high-use locations
(kitchen, porch/outdoors, and one other location)
2 POINTS

This Action item is required for credit in the program if you are installing screw-in compacts for conventional
fixtures. If you don’t provide additional bulbs, the homeowner may go back to incandescent bulbs when
replacements are needed.

If you provide dedicated fixtures AND replacement bulbs, you receive 1 point.

Compact fluorescent lights (CFL) have a higher first cost (up to $10 to $12 more), but advanced technology
enables CFLs to use 75% less energy than a standard incandescent bulb and last up to 10 times longer. This means
93
that over the life of one CFL, a consumer can avoid replacing up to 13 incandescent bulbs! The super efficient
performance of CFLs also means a consumer can save at least $25.00 in energy costs over the life of each CFL that
replaces an incandescent bulb. Modular compact fluorescent lights can save the customer even more, because as
lamps fail, only the lamp itself, and not the ballast, has to be replaced.

Furthermore, earlier objections to the quality of fluorescent lights no longer holds merit because newer bulbs
produce a warm light with good color rendering similar to incandescents, while electronic ballasts eliminate the
hum, flicker, and delayed illumination time, which were common with older models.

Fluorescent bulbs that meet ISO 9000 standards are low-mercury or mercury-free.

3-74 Install hard-wired fluorescent- or LED-lighting


1 POINT FOR EACH 5% OF LIGHTING BEYOND REQUIRED CODE
5 POINTS MAXIMUM

The purpose of hard-wiring fluorescent fixtures is to guarantee they will stay as dedicated fluorescent fixtures
without the possibility of reverting to incandescent bulbs that do not offer the same energy efficiencies. New
systems are available with a twist-lock ballast which makes it very compact and makes it possible to easily switch
the ballast for replacement or the change the wattage of the fixture.

3-75 Install fluorescents or LED lights on dimmer


1 POINT PER INSTALLED DIMMER
3 POINTS MAXIMUM

Dimmable fixtures allow adjustment of lighting levels to meet user requirements and increase occupant comfort.
Dimmable compact fluorescent lamps are available for modular ballast that can be hard-wired within a fixture.

Resources
• “Dimmable Compact Fluorescent Lamps” by Washington State University Cooperative Extension Energy
Program. Fact Sheet is available online at
www.energy.wsu.edu/documents/building/light/compact_fluor.pdf.

3-76 Use interior occupancy sensors, e.g. timers, motions detectors


1 POINT PER ITEM
3 POINTS MAXIMUM

Occupancy sensors for closets, pantries, and utility rooms provide a convenient way to turn on and off lights. This
reduces the chances of accidentally leaving lights turned on.

3-77 Install photo cells, timers, motion detectors (exterior)(beyond Energy Code
requirements)
1 POINT

Dimmers allow you to use one light for many purposes, and can save energy and extend the life of most bulbs
when used at lower levels. Look for full-range dimmers that vary the light continuously from off to full brightness.
Dimmers can be used with incandescent lights, including low voltage systems, and with compact fluorescents.
There are several choices of wall-mounted dimmers: toggle, rotary, sliding, solid-state touch, and new integrated
systems with remote controls that can recall previous lighting levels. If several high-wattage incandescent lamps
are to be controlled at one point, add a hard-wired dimmer.
94
Photo Cells, thin-film devices that work by generating a current when exposed to light, thus this technology can
be used as a light sensor for lighting devices.

Timers can be located at a light switch, a plug, or in a socket, and are available as both mechanical and solid-state.
Some offer the option of a manual override. Some screw-base compact fluorescent bulbs cannot be used with
timers; check manufacturer’s recommendations.

Motion detectors or occupancy sensors can result in significant energy savings, especially in bathrooms and
bedrooms where lights are frequently left on. Sensors can have manual on/off switches or can operate entirely
automatically. Motion detectors should not be used with some compact fluorescents, or with high intensity
discharge lights because of their inability to relight quickly. Some models feature dimmers that reduce light to a
preset level rather than turn completely off; others come with photosensors that turn lights on only when the light
level is below a preset point and motion is detected.

Light-sensing controls are increasingly being used to control outdoor lights along driveways and walkways.
Consider motion detectors and photosensors for energy efficiency. Consult with your lighting supplier for optimal
placement.

Resources
See your local lighting supplier for suggestions.

3-78 Install LED lighting in high-use location


1 POINT

If you think fluorescent light is energy-efficient, take a look at new LED (light emitting diode) lighting options.
LED lights consume less than a quarter of the electricity that fluorescents do and less than 90% compared to
incandescent bulbs. The lighting quality is comparable to that of cool white compact fluorescent lamps. Currently,
there are a limited number of manufacturers, but that is expected to change. In the meantime, light bulbs, bars
and strips, task lighting, floodlights, and controls for interior and exterior applications.

Resources
• See also the NAHB Research Center’s ToolBase TechSpecs on LED Lighting, available online at:
www.toolbase.org/Technology-Inventory/Electrical-Electronics/white-LED-lighting.

3-79 Install switches for wall outlets (phantom load switches)


2 POINTS

3-80 Install no recessed can lights that penetrate the building's thermal envelope
5 POINTS

Appliances

95
All appliances installed in the home should be as energy efficient as possible. The reduced electrical costs for
operating energy efficient appliances rapidly offset slightly higher initial costs, if any.

The “Energy Guide” or ENERGY STAR labels found on many appliances identifies energy efficiency. Also, look for the
following energy-saving characteristics:

• Refrigerator/Freezer—Energy-efficient characteristics include freezer-on-top arrangement (rather than


side-by-side), manual defrost, and absence of through-the-door dispensers and automatic icemakers. In
general, the larger the refrigerator, the more energy it takes to run. However, newer models with some of
these features compensate for the energy penalty with advanced insulation systems.
• Dishwasher—The primary cost of running a dishwasher is the cost of heating the water. Energy saving
features include light load options and air circulation for drying. Also, the smaller the machine the less
energy required to run a load. If you are building a home for a large family, though, it will be better to
install a larger machine that can be run fewer times a day.
• Washing Machine—Similar to the dishwasher, the primary energy cost is in heating the water. Energy
saving features include options for cold water wash and small loads. In general, front-loading washing
machines use one-third less water than top-loading machines, and research shows they do a better job of
cleaning the clothes.
• Dryer—The primary energy saving feature is automatic shut-off when the clothes are dry.

3-81 Provide an outdoor clothesline


1 POINT

A permanent clothesline can save energy and help reduce air pollution by reducing use of the clothes dryer
(frequency and/or load volume). An outdoor location avoids moisture problems in the home. Using only a
clothesline, instead of electric or gas dryer saves an average of 1,000 kWh of electricity a year.

3-82 Install gas clothes dryer


1 POINT

In new construction, installation of a gas clothes dryer in lieu of an electric one will result in cost savings to the
homeowner, even considering installation of the additional gas piping. Typically gas clothes dryers cost $40 more
than electric models. Cost for fuel piping when installed during construction is minimal.

Resources
Clothes dryers are not required to display Energy Guide labels. Unlike most other types of appliances, energy
consumption does not vary significantly among comparable models of clothes dryers. Here are some consumer
buying tips from the US Department of Energy:

• Look for a clothes dryer with a moisture sensor that automatically shuts off the machine when your
clothes are dry. Not only will this save energy, it will reduce the wear and tear on clothes from over-drying.
• The best dryers have moisture sensors in the drum for sensing dryness, while most only infer dryness by
sensing the temperature of the exhaust air. Compared with timed drying, you can save about 10% with a
temperature sensing control, and 15% with a moisture sensing control.
• Look for a dryer with a cycle that includes a cool-down period, sometimes known as a “perma-press”
cycle. In the last few minutes of the cycle, cool air, rather than heated air, is blown through the tumbling
clothes to complete the drying process.

3-83 Install front loading or ENERGY STAR washing machine


2 POINTS
96
Front loading or horizontal-axis (H-axis) clothes washers offer significant water and energy efficiencies (up to 30%
less) compared to vertical-axis machines. Additionally, clothes coming out of the H-axis washer at the end of the
wash cycle contain less water compared to conventional washers. This reduces dryer energy use as well. Finally,
H-axis wasters are gentler on clothes so they last longer. All these benefits are features you can “sell” to your
clients.

Figure 3-11 Clothes Washer Horizontal Axis


Configuration
Figure 3-10 Clothes Washer Vertical Axis
Configuration

(Source: City of Santa Barbara, CA Public Works Department)

Resources
The EPA lists online products that currently qualify for the ENERGY STAR label and a store locator, see
www.epa.gov/appdstar/estar/products.html. Or e-mail labeling@energystar.gov or call the ENERGY STAR hotline
at 1-888-STAR-YES. The ENERGY STAR database provides a calculation of the annual energy use based on the
number of loads washed per week. Savings to the homeowner depend on the cost of heating hot water and the
number of loads washed per week.

• “A New Spin On Clothes Washers,” Consumer Reports, July 1998, pp. 50-53. A good comparison of
front-loading versus top-loading washing machines. Consumer Reports also periodically reviews clothes
washers; check the most recent index, www.consumerreports.com.
Consumer Guide to Home Energy Savings, by Alex Wilson and John Morrill, is updated annually (See General
Resources above). For the washers listed as “Top-Rated Energy-Efficient,” see
www.aceee.org/consumerguide/topwash.htm.
• WSU Cooperative Extension Energy Program can provide you with consumer fact sheets on
energy-efficient appliances, 360-956-2000, or www.energy.wsu.edu. You can include these fact sheets in
the Homeowner’s Kit (see below).
• “New Generation of Horizontal-Axis Washing Machines on the Way,” Environmental Building News Volume
6, Number 4, April 1997. Available online at www.buildinggreen.com/products/washers.html.

3-84 Install an ENERGY STAR dishwasher


1 POINT

As with other home appliances, national energy standards have spurred the development of more efficient
dishwashers. Energy- and water-efficiency are closely related in dishwashers except for booster heating and
drying cycles. The most water-efficient dishwashers use as little as 3.9 gallons per cycle at the economy setting.
Energy savings range from 80 kWh per year to 364 kWh per year. Some of the most efficient dishwashers also
operate significantly more quietly than conventional dishwashers.

97
You can market your selection of an extra-efficient dishwater to the homeowner from several perspectives—
performance, water and energy efficiency, ease of use, total features, quiet operation, and reliability.

Resources
®
Dishwashers with increased efficiency are most easily identified by the ENERGY STAR label. The EPA lists online
®
products that currently qualify for the ENERGY STAR label and a store locator, see
®
www.epa.gov/appdstar/estar/products.html. Or e-mail labeling@energystar.gov or call the ENERGY STAR hotline
at 1-888-STAR-YES.

• “Clean Enough for You?” Consumer Reports, March 2000, pages 47-50, www.consumerreports.com.
“Dishing it Out,” Consumer Reports, March 1999, pages 50-53.
• Consumer Guide to Home Energy Savings, by Alex Wilson and John Morrill, is updated annually (See General
Resources above). For the dishwashers listed as “Top-Rated Energy-Efficient,” see
www.aceee.org/consumerguide/topwash.htm.
See also GreenSpec and the REDI Guide for more information.

3-85 Install ENERGY STAR refrigerator


1 POINT

ENERGY STAR refrigerators are at least 20% more efficient than the current federal minimum standard. Energy
savings range from 125 kWh per year to 320 kWh per year, depending on size, style, and features. A cost effective
consumer investment ranges from $25 to $125.

Resources
®
Refrigerators with increased efficiency are most easily identified by the ENERGY STAR label. The EPA lists online
®
products that currently qualify for the ENERGY STAR label and a store locator, see
www.energystar.gov/index.cfm?c=refrig.pr_refrigerators. Or e-mail labeling@energystar.gov or call the ENERGY
®
STAR hotline at 1-888-STAR-YES.

3-86 Install ENERGY STAR exhaust fan vented to outside


1 POINT

ENERGY STAR rated exhaust fans are available that will use less energy for the same amount of ventilation than
non-Energy Star units.

Resources
• “An Introduction to IAQ” is provided by U.S. Environmental Protection Agency, www.epa.gov/iaq/co.html.

3-87 Install induction range


2 POINTS

3-88 Install energy monitoring device in home


3 POINTS

98
ALTERNATIVE ENERGY

3-89 Enroll the residence in the local utility’s electricity program for renewable
electricity sources
BUILDER ENROLLED: 2 POINTS
ENROLLMENT TRANSITIONED TO OWNER: 3 POINTS

Currently, it costs more to build wind, solar and biomass generating facilities. By signing up for your local utility’s
voluntary green power program which supports renewable energy production, electricity producers are given the
necessary backing to promote more environmentally friendly resources. As more renewable energy is used, less
air and water pollution are produced. Support your utilities' voluntary renewable energy programs through a
simple sign-up process. Suggested initial participation lengths are one year for builders, two years for
homeowner.

3-90 Pre-pipe for solar water heater


2 POINTS

If installing a solar water heating system (see 3-91, Solar Water Heating System Sized to Provide a Minimum of 40%
Hot Water Designed Energy Use above) is not a part of the new construction budget, you can pre-pipe the house
during construction to allow for the owner/tenant to install solar water heat at a later date. As energy prices rise
and fuel availability becomes uncertain, pre-piping the house for adding solar water heating make remodeling so
much easier – a real selling points to your customers.

Resources
See General Resources, particularly the field guides.

3-91 Solar water heating system sized to provide a minimum of 40% hot water
designed energy use
10 POINTS
NOT APPLICABLE IF CLAIMING UNDER WSEC TABLE 406.2

Solar energy can meet part or all of a home’s domestic hot water needs. Geographic location, system design,
collector orientation, and collector size will determine how much energy can be provided for domestic hot water
heating. A solar water heating system may result in immediate positive cash flow if the monthly cost of financing
the system is less than the net savings.

Limitations include the need for regular maintenance, a relatively high initial cost, and a long payback period.
Solar panels may be aesthetically unacceptable to some. Lastly there is potential for freezing with passive
systems. Check local building codes to determine codes related to the installation of solar water heaters. The
Solar Ratings and Certification Corporation runs a certification program for solar water heating systems.

To receive this credit the Solar Water Heating System must be sized to provide a minimum of 40% hot water
designed energy use.

Resources
See the REDI Guide and GreenSpec (See General Resources above) for solar water heating systems product
information.

3-92 Percentage or all of home powered by renewable energy source

99
5 POINTS PER KW
25 POINTS MAXIMUM

Photovoltaic (PV) modules convert sunlight directly into electricity. Some systems have been poorly accepted
because homeowners consider the structure unattractive. However, newer PV modules can be integrated into
roofing materials, replacing traditional PV modules that are mounted on rooftop racks. Once installed, PV roofing
produces free electricity from sunlight that can power certain home functions or supply the entire electrical needs
of a home and eliminate the need to connect to the utility grid.

PV roofing products provide environmental benefits because they do not produce pollution or carbon dioxide
emissions like fossil fuel-based utility power. They are also more attractive than many other solar systems, which
increases consumer acceptance.

The cost for PV installations is dropping. For homes not in proximity of electric power lines, PV systems may be
less costly than extending power lines to the home. Unlike generators, they operate silently and require little
maintenance.

Non-solar renewable power systems that could add to the houses’ total energy production include wind power,
waterpower, or biofuel.

Small wind systems are available for residential applications. A wind turbine typically lowers a household
electricity bill by 50% to 90%. The amount of money a small wind turbine saves you in the long run will depend
upon its cost, the amount of electricity you use, the average wind speed at your site, and other factors.

3-93 Provide designated location on south roof area and rough-in conduit for wiring
and controls for future solar thermal and photovoltaics
4 POINTS

Consumer interest in renewable energy is high. Pre-wiring and/or plumbing for a future PV solar energy or solar
hot water system installation is a cost-effective way for builders to provide a future renewable energy option for
new home owners. This installation allows the homeowners to add a solar energy system to their home, and the
option of easy future PV becomes a selling point for builders. Using this Action item is a great way to “future-
proof” a house. A retrofit system after construction costs more than the pre-wire option.

Extra Credit for Energy Efficiency

3-94 Extra credit for innovation in Energy Efficiency


1-10 POINTS

You may submit an energy saving strategy or system, not specifically called out in this Section, for consideration
for an Extra Credit for Innovation. All extra credits will be approved by the Program Director. If approved, add up
to 10 points to your Section total.

Section 4 HEATH & INDOOR AIR QUALITY

General Resources
• For Washington State Ventilation and Indoor Air Quality Code resources, see Section One Resources: Build to “Green” Codes/
Regulations and Program Requirements.

100
• For specialists in healthy design and construction, see listings in Green Pages for Architects, Builders and General Contractors,
Building Design, Building Materials and Supplies, Healthcare and Enviro-Illness, and Indoor Air Quality (see Green Pages under
General Resources, below.)
th
• Washington State Energy Code Builder’s Field Guide, 6 edition, 2004. Available through WSU Cooperative Extension,
Educational Materials. This guide is available in PDF for free on the Internet at
www.energy.wsu.edu/documents/code/bfg/2004/BFG_Full_2004.pdf
• “Energy Ideas Clearinghouse.” The EIC is your library for information on energy efficient construction. EIC will provide
customized responses to specific questions about energy efficiency, moisture control, ventilation, and green building. 800-872-
3568 or e-mail EnergyLine@energy.wsu.edu. Or you can browse for resources yourself online at www.energyideas.org. The
EIC is funded by the Northwest Energy Alliance, Olympia, WA, www.nwalliance.org.
• NAHB Research Center’s “Tool Base Hotline” is available to answer builder questions, 800-898-2842,
www.nahbcrc.org/ToolBase.
• Building Science Corporation website, www.buildingscience.com. Offers useful information regarding frequently found
problems in buildings and how to avoid them. Moisture control is emphasized. Also available from this site is Joe Lstiburek’s
Builder’s Guide, published by Building Science Corporation, Westford, MA, 978-589-5100.
• Environmental Building News, Brattleboro, VT, 802-257-7300, www.buildinggreen.com.
• Building Concerns Newsletter, by Building Concerns, Mill Valley, CA, 415-389-8049, www.interiorconcerns.com.
• PATH, A Pulic-Private Partnership for Advancing Housing Technology, dedicated to accelerating the development and use of
technologies that radically improve the quality, durability, energy efficiency, environmental performance, and affordability of
America's housing, http://pathnet.org/.

Product Information
• GreenSpec—The Environmental Building News Product Directory and Guideline Specifications, E Build, Inc., Brattleboro, VT,
1999. GreenSpec is organized in standard CSI Divisions. Environmental Building News also offers product reviews, information,
and also posts some journal articles at www.buildinggreen.com/products/productslist.html.
• REDI Guide (Resources for Environmental Design Index), web database, diskette, or printed handbook; a good resource for
energy-efficient products. Available from Iris Communications, Eugene, OR, 800-346-0104, or online at
data.oikos.com/products.

Technical Books and Guides


• Builder’s Guide, by Joe Lstiburek. Published for four climate versions (For Pacific Northwest, appropriate climate type is
“Mixed-Humid.”) The guide includes illustrations and resources for such subjects as house layout and design, foundations,
framing, HVAC, insulation, drywall, plumbing, electrical systems, painting, sheathings, and windows all with respect to
moisture control, energy efficiency, and proper ventilation. Published by and available from Building Science Corporation. 70
Main Street, Westford, MA. 978-589-5100, or www.buildingscience.com/books.html. Cost is $40.00 plus S&H. Also available
from the Journal of Light Construction Bookstore: phone 800-859-3669 or online at www.jlconline.com/bookstore.
• Healthy by Design: Building and Remodeling Solutions for Creating Healthy Homes, by David Rousseau and James Wasley,
Hartley & Marks Publishers, Point Roberts, WA. Available from IRIS Communications, Eugene, OR, 800-346-104,
shop.oikos.com/catalog.
• Healthy House Building for the New Millineum, John Bower, The Healthy House Institute, Bloomington, IN, 812-332-5073,
www.hhinst.com. Good information on optimizing air distribution and ventilation.
• Moisture Control Handbook: Principles and Practices for Residential and Small Commercial Buildings, by Joseph Lstiburek and
John Carmody, published by John Wiley & Sons. Deals almost exclusively with moisture and water management. Some of the
areas covered, including illustrations, are moisture movement, wall assemblies in various climates, moisture control practices
in various climates, case studies/moisture problems that create mold, odor, roof decay, and condensation, peeling paint on
wood trim, and hardboard panel problems. Available from Building Science Corporation, Westford, MA, 978-589-5100 or
shop.oikos.com/catalog.

101
• Prescriptions for a Healthy House, A Practical Guide for Architects, Builders, and Homeowners, Paul Baker, AIA, Eric Elliott, MD,
and John Banta, InWord Press, Santa Fe, NM. Identifies the full range of potential indoor health problems and then offers
solutions. Organized by CSI Divisions and includes specification language for construction documents. Available from Iris
Communications in Eugene, OR, 800-346-0104 or www.oikos.com/catalog.
• Sustainable Building Technical Manual: Green Building Design, Construction, and Operations, produced by Public Technology,
Inc., U.S. Green Building Council (USGBC), and U.S. Department of Energy, with support from EPA, 1996. Useful for
multi-family projects. Available from USGBC, San Francisco, CA. 415-445-9500 or order online at www.usgbc.org/resource
($68).

OVERALL

4-1 Interact w/ homeowner early in design/construction process to identify chemical


sensitivities and preferred IAQ measures and finishes
4 POINTS

THIS CREDIT IS ONLY AVAILABLE TO CUSTOM OR PRE-SOLD PROJECTS WITH CHEMICALLY-SENSITIVE


CLIENTS.

If your client suspects they have chemical sensitivities, recommend that they be assessed by a medical
professional with training in diagnosing chemical sensitivities. If they are chemically sensitive, allergic, or have
asthma they will probably require special measures. Pay close attention to information your client provides you
about their medical conditions/sensitivities, and work closely with them and their medical professional to identify
required measures. Considerations should include:

• Specific building materials to be avoided.


• Required thresholds for moisture level control (below 50% is best to minimize molds and dust mites).
• Optimum ventilation system.
• Optimum filtration for heating and/or ventilation systems.
If you do not specialize in building for chemically sensitive clients, you should recommend including a specialist on
your building team. You may be called upon to provide building materials for tests.

4-2 Project team member to have taken American Lung Association (ALA) of
Washington “Healthy House Professional Training” course or other IAQ class with
8 hours of curriculum minimum
5 POINTS

The American Lung Association offers training, which provides an in-depth focus on indoor air quality issues in
residential construction. Topics covered include indoor air quality and health, design and energy issues, material
selection, dust and moisture control, ventilation and filtration methods, and pesticide and chemical usage. The
course is open to the public, but is targeted to building professionals, including architects, builders, industrial
hygienists, engineers, interior designers, and others.

This credit is available to project team members who take this course or other Indoor Air Quality (IAQ) class with 8
hours of curriculum minimum.

Resources
The American Lung Association Health House Builder Program provides training see
http://www.healthhouse.org/build/index.asp or contact the local office.

102
4-3 Certify the home to a third-party verified program emphasizing indoor air quality
(e.g., EPA Indoor airPLUS, American Lung Association Health House)
15 POINTS

Certify House under ALA or other Program approved by the BUILT GREEN Director

The American Lung Association developed the Health House Project in 1993 and today, Health
House is nationally recognized for raising the standards of residential air quality and energy
efficiency.

The Health House (HHA) program is a comprehensive “whole house” program for nationwide
use to reduce illness in the home due to poor indoor air quality. The Health House is built to
climate-specific construction and product criteria established by the national Health House
Technical Review Committee. The criteria include house tightness, air handler and ductwork tightness, zonal
pressure balance, whole-house filtration and mechanical ventilation, sealed combustion heating, ventilation and
cooling (HVAC) appliances, and humidity control. The Health House undergoes a series of performance tests to
determine if it has been built to meet or exceed these standards. A team of diagnosticians tests the house to
evaluate its overall performance in the areas of energy efficiency, house pressurization, air infiltration, and indoor
air quality. Some houses are selected for monitoring over a period of time to determine ongoing performance.

Individual contractors wishing to certify the home through the HHA program will need to contact the American
Lung Association to confirm current qualifying requirements, such as technical measures that must be taken in
design and construction, training, and inspection(s). Technical assistance and education are part of the
certification process. This approach is likely to add cost to the home package and represents an extra effort in
terms of time working closely with the ALA, including attending a two-day training session. Hence the significant
credit of 15 points for obtaining this certification.

The American Lung Association of Minnesota Health House Program, St. Paul, MN 651-223-9568 or 651-268-7587,
certifies homes and builders. For a database listing all Health House certified builders across the US, see
www.healthhouse.org or e-mail info@healthhouse.org. The Builder Guidelines are available at
www.healthhouse.org/build/guidelines.asp.

4-4 Design for soundproof area in home


3 POINTS

JOBSITE OPERATIONS

4-5 Use less-toxic cleaners


1 POINT

Cleaners and solvents can be sources of hundreds of potentially harmful chemicals. Review manufacturer’s
Material Safety Data Sheets (MSDS) before you buy. Avoid products that are given a health hazards rating higher
than “1.” In addition, avoid as much as possible products with ingredients that the MSDS classifies as toxic
(poisonous), flammable, caustic (causes burns), or chemically reactive. Leftovers of these products will be
hazardous waste. (For proper hazardous waste handling and disposal procedures, see Action items, 2-50
(Establish and Post Cleanup Procedures for Spills to Prevent Illegal Discharges), and 2-51 (Reduce Hazardous Waste
through Good Jobsite Housekeeping).).

Use environmentally friendly alternatives, including biodegradable products and those that are zero-VOC or
low-VOC (no- to low-volatile organic compounds).

103
Resources
• Citra-Solv from Shadow Lake Inc., Ridgefield, CT, 800-343-6588 is sold in concentrated form in many local
grocery or department stores (such as Fred Meyer) and hardware stores. Lists of vendors are available on
the website www.citra-solv.com. Do not use on vinyl as the product will dissolve it.
• Red Devil TSP/90 Heavy Duty Cleaner from Red Devil, Inc., Union, NJ, 800-4-A-Devil. Red Devil also has a
phosphate-free product, which is sold in most paint and hardware sores, www.reddevil.com.
Also see GreenSpec, listed under Resources, Product Information above.

4-6 Require workers to use VOC-safe masks when applying VOC containing wet
products, and N-95 dust masks when generating dust
1 POINT

For small projects with short exposures to VOCs, a gray carbon-impregnated dust mask manufactured by 3M or
equivalent should suffice. These masks are readily available at most lumberyards and run about $4 to $5 each.

Whenever workers are exposed to off-gassing or fine particulates (for example, from paints, solvents, adhesives,
molds or finishes), a flexible half-mask equipped with two or three straps to ensure a tight fit should be worn.
Filter cartridges are used to complete the mask. They are color-coded to identify the kind of contaminant they are
designed to capture. Cartridges designed to capture VOCs are black and filled with activated charcoal. When the
charcoal becomes saturated (end of life), the operator will begin to smell the vapor, signifying that it is time to
change the filter. To extend the life of the filter, store in a plastic bag between uses. The mask usually costs under
$30; a set of filters can run from $30 to $50.

Note: Filtration through a mask is actually the least effective method of reducing worker exposure to volatile
organic compounds (VOCs) resulting from applying paints, thinners, and solvents. The best method is to eliminate
or reduce the problem in the first place by choosing low- or non-toxic alternatives and keeping the work area
thoroughly ventilated (see Action items 4-30, Inside the House, Use Only Low-VOC, Low-Toxic, Water-Based,
Solvent-Free Sealers, Grouts, Mortars, Caulks, Adhesives, Stains, Pigments, and Additives, and 4-42, Use Only
Low-VOC/Low-Toxic Interior Paints and Finishes for Large Surface Areas).

For dust generating activities, specify N95 particulate masks to help filter out fine airborne particles including
pollens, dander, mite allergen, mold spores, and microorganisms by using advanced electrostatically charged
microfibers. This mask can be worn for long periods of time until it becomes damaged, soiled, or breathing
becomes difficult. NIOSH government-approved N95 Respirator provides at least 95% filtration against non-oil
particles.

Resources
Dust and paint masks for limited exposure are manufactured by 3M. These gray carbon- impregnated masks cost
around $4 to $5 each. For more information see:

• “Suit Up, OSHA-Style,” Journal of Light Construction, July 1995, 800-859-3669 or www.jlconline.com.
• “Protecting Your Lungs on the Job,” Fine Home Building, April/May 1994, 800-888-8286,
www.taunton.com/fh. Or call the National Institute for Occupational Safety and Health (NIOSH) at
800-356-4674, www.cdc.gov/niosh.
• General Occupational Health Standards, WAC Chapter 296-62, Part C: “Hazard Communication,”
www.lni.wa.gov/wisha/regs/wasindex.htm. (Requirements for notifying workers of jobsite hazards.)

4-7 Take measures during construction operations to avoid moisture problems later
1 POINT PER 4 MEASURES
3 POINTS MAXIMUM

104
Moisture problems in today’s “tight” buildings are always a concern. Measures to take during construction
operations to avoid moisture problems down the road are worth the investment for the air quality and building
structure considerations.

• Keep stored materials dry with tarps or in a protected place, or use just in time delivery to avoid problems
with stored materials.
• Use a moisture meter to make sure moisture content of underlayment, sheathing, and framing materials
does not exceed 15%. If readings exceed 15%, dehumidify before installing insulation and drywall.
• Protect woodwork from moisture damage during transit, delivery, storage, and handling.
• Expanded Requirements include Basic plus
• Pump or drain standing water out of the structure after major rainstorms.
• Hook up installed rain gutters to temporary pipes to draw water away from foundation.
• Install dimpled drainage mats at foundation walls.
• Use flashing instead of caulking to seal above doors, windows, and other openings.
• Properly counter flash chimneys and build a cricket above chimney to divert water.
• Properly flash all roof to wall intersections.
• Avoid flat roofs.
• Use quiet fans (1.5 sonos or less) bathrooms with a 60 minute timer. Noisy fans will not get used.
• During construction, remove unwanted moisture with a dehumidifier, not combustion heaters, which only
bring more moisture into the home.

Resources
• Builder’s Guide (listed in Resources, Technical Books and Guides, above).
• Moisture Control Handbook: Principles and Practices for Residential and Small Commercial Buildings by
Joseph Lstiburek and John Carmody. (listed in Resources, Technical Books and Guides, above.)
• “Energy Ideas Clearinghouse.” The EIC will provide customized responses to specific questions moisture
control. (See General Resources, above.)
• The Building Science Corporation website www.buildingscience.com. This website site offers useful
information, emphasizing moisture control. (See General Resources, above.)

4-8 Take measures to avoid problems due to construction dust


2 POINTS

MUST PERFORM ALL MEASURES TO GET POINTS

Ideally, the HVAC system should not be used during construction to void potential contamination of the system.
Using temporary space heaters is feasible and generally doesn’t cost more. Other preventive measures to avoid
subsequent problems resulting from construction dust include:

• Seal all ductwork to protect from dust and other contaminants during construction
• Mask floor registers or use temporary screens or protective boxes to prevent debris from accumulating
during construction (see Resources section for product information)
• If using the HVAC system, install construction filters—Change them after construction is done, then flush
and change them again (mechanical contractor can do this). A MERV of 8 at each return air grill if handlers
must be used during construction

105
• Clean/vacuum up dirt, dust, and wood shavings as you go
• Vacuum stud bays before sheet-rocking
• Vacuum the floors before final flooring installation
• Isolate areas of work to avoid contamination of clean spaces

Resources
• ZipWall is a temporary dust barrier that is both easy to install and does not damage ceiling, wall, or floor
finishes. Telescopic poles friction-seal plastic, canvas, or dropcloth material against ceiling and floor.
Zipwall, Stamford, CT, 800-718-2255 or www.zipwall.com.
• FEIN Power Tools Inc. claims its FEIN Sander with Fein Turbo II Vacuum eliminates 98% of the dust created
by sanding. 800-441-9878.
• Mechanical contractors provide services or check your yellow pages for duct-cleaning services.

4-9 Implement comprehensive dust control plan as described in handbook


3 POINTS

Dust is an increasing concern in this area. Dust is generated by the landscape & wind to some extent, but
exacerbated by soil disturbance, grading, creating wind tunnels, or declining habitat & vegetation. A
comprehensive dust control plan address dust concerns both during construction and after the occupant has
moved in. To earn points for this Action item, each of the following must be completed:

• Do not use diesel fuel for dust control on the construction site and roads. Green alternatives exist, such as
road coat (a vegetable oil) and envi-rox 2000. (Refer to Part II, Resources for more information about these
products.)
• Do not install any woodburning fireplaces
• Implement Action item 2-25, Set aside a % of the site to be left undisturbed, emphasizing protection of
critical areas, wildlife habitat, and dust control, for at least 25% of the site
• Implement Action item 2-33: Limit grading to 15 feet around structures, septic, ground-source heat pump
fields, except for driveway acces.
• Limit grading to an average of 20ft outside building footprint
• Apply a green dust control joint compound (Refer to Part II, Resources for more information about these
products.)
• Implement Action item 2-44, Use pervious materials for driveways, parking areas, walkways, and patios
• Install a Merv 12 or better filter

Resources
Check with local jurisdiction for dust control requirements for construction projects.

• Techniques for Dust Prevention and Suppression (Publication #96-433, March 2003). Washington
Department of Ecology publication to assist in dust prevention strategies,
http://www.ecy.wa.gov/pubs/96433.pdf.

4-10 Use moisture meter to ensure moisture levels are 19% or less in walls, 12% or less
in floors before closing up, installing drywall, and finish floors

106
2 POINTS

Moisture problems in today’s “tight” buildings are always a concern.

Use a moisture meter to make sure moisture content of sheathing and framing materials does not exceed 19% or
less in walls, sub-floors should be below 12% or less in floors before closing up, installing drywall, and finish floors
are installed.

If readings exceed these levels, dehumidify before installing insulation and drywall (See Action item 4-12, No use
of unvented combustion-type heaters during construction

4-11 Ventilate with box fans in windows blowing out during drywall sanding and new
wet finish applications
3 POINTS

Each new finish (for example, paints, stains, and floor finishes) will off-gas for a time after it is applied. Emissions
are highest immediately after the finish is applied. It is important to ventilate the house with fans (several box fans
in windows work best) so that gases will be exhausted outside. Venting out should continue for at least two and up
to seven days after each application, depending on the amount of surface covered and the toxicity of the finish.
(For toxic finishes applied over large areas, vent for seven days.) Use construction filters and change them out
before occupancy. If the house is not properly ventilated during this phase, the emitted gases will adhere to
surfaces in the house and later re-release into the indoor environment.

4-12 No use of unvented combustion-type heaters during construction


3 POINTS

The use of unvented combustion heaters produces excess moisture that can become trapped inside framing
members during construction, leading to subsequent moisture damage. In addition, they produce fumes that can
be hazardous to workers. Instead use a vented heater or portable electric heater.

Also, do not use the home’s heating system during construction. Instead, start up the heating system for testing
and balancing just before the owners move in.

Note: Often heaters are used to “dry out” the building following a rainstorm.

Heating options includes using a dehumidifier or an electric heater.

4-13 Block all duct ports upon installation and no use of ducted HVAC
2 POINTS

During construction, debris often enters through the registers to collect in the ducting. Unless removed, fine
particles from the debris, which can be respiratory irritants, can circulate within the ducts and re‑enter the spaces
through the registers, and can lead to reduced HVAC system life. To prevent contamination, do not use the ducted
HVAC during construction. Should any contaminants make their way into the duct work, they should be removed
by a professional duct cleaning company in the final stages of construction before owners move in. A professional
duct cleaning company should thoroughly clean and vacuum ducts, and also replace filters from construction.

4-14 Clean duct and furnace thoroughly just before owners/tenants move-in
3 POINTS

107
During construction, debris often enters through the registers to collect in the ducting. Unless removed, fine
particles from the debris, which can be respiratory irritants, can circulate within the ducts and re-enter the spaces
through the registers.

To receive points you must meet Action item 4-10 , Do Not Use the Ducted HVAC System During Construction.

In the final stages of construction and before owners move in, thoroughly clean and vacuum ducts to remove any
particles that may have entered during construction.

Resources
Mechanical contractors provide services or check your yellow pages for duct-cleaning services.

4-15 No smoking inside of any building or within 25 ft. (or more) radius of exterior of
any building
2 POINTS

4-16 Train subs in implementing a healthy building jobsite plan for the project and
contractually require compliance
4 POINTS TO TRAIN SUBS IN IMPLEMENTING A HEALTHY BUILDING JOBSITE PLAN FOR THE PROJECT
+4 POINTS IF CONTRACTUALLY REQUIRE COMPLIANCE

To implement healthy building jobsite plan, it is important to enlist the support and cooperation of your
subcontractors, especially painters, floor finishers, cabinet maker, as well as any others that will be applying
adhesives and caulks indoors (for example, flooring installers, countertop installers, finish carpenters, framers,
plumbers, and HVAC contractors). Before the job begins and during on-site work, coordinate with them about:

• Using low toxic materials (See Action items 4-30, Inside the House, Use Only Low-VOC, Low-Toxic,
Water-Based, Solvent-Free Sealers, Grouts, Mortars, Caulks, Adhesives, Stains, Pigments, and Additives,
and 4-32, Use Only Low-VOC/Low-Toxic Interior Paints and Finishes for Large Surface Areas).
• Venting out the building during and after each finish is applied
• Preventing moisture accumulation and entrapment in the structure during construction that could cause
mold growth or other damage during the life of the structure (See Action item 4-7, Take measures during
construction operations to avoid moisture problems later.
• Using only electric or vented heaters during construction (See Action 4-12, No use of unvented
combustion-type heaters during construction. Use dehumidifiers, if needed, to dry out the building during
construction
• Prohibiting smoking in the structure enclosure.
• Coordinating closely with HVAC and electrical contractors for installation of whole house ventilation and
quiet spot ventilation in wet areas.
• Making sure any toxic materials such as asbestos, or lead are handled properly. (See Action items 2-50,
Establish and post clean up procedures for spills to prevent illegal discharges and 2-51 (Reduce Hazardous
Waste through Good Jobsite Housekeeping)..

4-17 Implement a “no-idle zone policy” for equipment and vehicles not in active use
2 POINTS

108
The No-Idle Zone Policy simply put is centered on a turn of the wrist: shutting off your car when stopped for 30
seconds or longer. The policy will reduce tailpipe emissions and save on fuel costs. Post signage and involve and
train subs.

LAYOUT & MATERIAL SELECTION


How we finish and furnish our homes can impact the quality of the home’s indoor environment. This means
selecting products that are environmentally friendly, healthy, and low in formaldehyde and volatile organic
compounds. It also means using less carpet and other textiles and installing more flooring and other surfaces that
are smooth and easy to clean.

4-18 Use pre-finished flooring


1 POINT

A pre-finished floor is finished at the factory, often providing a tougher and more durable finish than can be
obtained with site-applied finishes and they will also have completed most of its off-gassing. Usually, pre-finished
flooring also offers the added benefits of not generating dust and odors associated with on-site sanding and
finishing of an unfinished product, but also can save time on installation.

Resources
Ask your local supplier for pre-finished flooring finished with durable, plant-based, water-based, and/or low toxic
finishes. Combine this Action item with others from the section, or see Chapter Five, Third-Party Certified Wood
credits.

4-19 No carpet
10 POINTS

Synthetic carpet off-gases when it is new. In addition, carpeting acts as a highly effective reservoir for allergens
such as dirt, pollen, mold spores, dust mites and other microbes. Moreover, as carpet wears out, the surface yarn
breaks down and becomes house dust. For that reason, this program encourages eliminating carpet (see Action
items, 4-24 If Using Carpet, Specify Products certified, 4-21, Install Low Pile or Less Allergen-Attracting Carpet and
Pad, and 4-23, Limit Use of Carpet to One-Third of Home’s Square Footage).

Resources
See GreenSpec, listed under Resources, Product Information, above, for environmentally friendly alternatives to
carpet.

Also see Section Five Resources, Action item 5-70, Use Natural Linoleum

4-20 If using carpet, specify products certified by third-party for indoor air quality
2 POINTS

New carpet can emit volatile organic compounds (VOCs) when first installed. Several labeling options are
available to help identify carpets that minimize the impact on indoor air quality.

The Carpet and Rug Institute has developed testing and labeling programs to aid in the
selection of low-emitting carpet, adhesives, and cushion materials.

Carpet bearing the CRI Green Label Plus indicates that:

The manufacturer voluntarily participates in these programs and is identified by an


assigned number in the label.

109
The manufacturer is committed to developing ways to minimize any adverse effects on indoor air quality.

A representative sample of the product type is tested by an independent laboratory and meets stringent
requirements for low chemical emissions. For specific requirements see Resource Section for link to requirement
criteria.

Greenguard Environmental Institute also offers a third-party certification program for Indoor Air Quality that
qualifies products as low emitting interior building materials. See the Resources Section for more information.

Resources
Most local suppliers are familiar with the CRI IAQ and Greenguard labels, www.greenguard.org/.

4-21 Install low-pile or less allergen-attracting carpet and pad


2 POINTS

Carpet off-gases when it is new. In addition, carpeting acts as a highly effective reservoir for allergens such as dirt,
pollen, mold spores, dust mites, and other toxins carried into the house by shoes. Moreover, as carpet wears out,
the surface yarn breaks down and becomes house dust. For that reason, this program encourages limiting or
eliminating carpet (see Action item 4-19, No Carpet).

However, if you do select carpet for the home, protect air quality by choosing a low pile type and installing it with
urethane padding. Preferably, select a carpet made from natural fibers, primarily wool (see Action item 4-30,
Install Natural Fiber Carpet, e.g. Wool) or an all-nylon carpet, which is less attractive to dust mites and mold. Also
look for recycled-content carpets (see Action item 5-68, If installing carpet, use recycled-content or renewed
carpet); the processed materials used in them tend to be less toxic than virgin synthetics. Finally, avoid dark
colors; these carpets contain more toxins than light carpets because more dye is needed to create the dark color.

Also, carpet should never be applied to a concrete slab unless provisions for a moisture/vapor retarder or
insulation have been incorporated in the slab that will allow the carpet to remain warm and dry. If not, moisture
can migrate through the floor and cause mold growth under the carpet.

Resources
Ask your supplier. Low-emission carpet/pad alternatives include:

• Nature’s Carpet, 100% natural wool carpet and pads manufactured without toxic chemicals,. Colin
Campbell and Sons, Vancouver, BC, 800-667-5001, www.colcam.com
• Bellbridge natural fiber carpets and pads, made by Bellbridge in Concord, CA: 800-227-3408.
• Bentley Mills low-VOC carpets, City of Industry, CA, 800-423-4709, www.bentleymills.com.
• Collins & Aikman low-VOC carpets, Dalton, GA, 706-259-9711 , www.powerbond.com. Or, call Collins &
Aikman’s Bellevue office, 425-641-1958.
• Harbinger carpet, Mohawk Industries, Dublin, GA, 800-241-4216, www.mohawkindustries.com. Harbinger
is actively involved in developing a conventional synthetic carpet with reduced rates of chemical
off-gassing.
• Homasote 440 Carpet Board, contains no asbestos or formaldehyde, and is made from recycled paper.
Homasote Company, West Trenton, NJ, 800-257-9491, www.homasote.com.
• Sustainable Lifestyles markets sisal floor coverings and sisal broadloom and area mats. Excelsior, MN,
800-287-3144.
See also resources for Action items 5-66, Use Recycled-Content Carpet Pad, and 5-68, If installing carpet, use
recycled-content or renewed carpet.

110
4-22 Install natural fiber carpet (e.g. jute, sisal, wool)
1 POINT

Today, 97% of all manufactured carpets consist of synthetic fibers. These synthetic components off-gas and the
glues that bind the fibers to the backing may contain chemical compounds, a number of which are known to be
toxic. Several companies make carpets with natural fibers, such as wool or cotton. However, these natural fiber
alternatives tend to cost more than synthetics. (Note: Even natural carpets can be a source of noxious gases if
treated with chemicals. For example, wool carpet is often moth-proofed.) Even natural fiber carpets may cause
allergic reactions in a very small percentage of the population.

An acceptable, cost-effective alternative is a low-pile, all nylon carpet (see Action item 4-21, Install Low Pile or Less
Allergen-Attracting Carpet and Pad).

Wool provides many benefits: it is soil and stain resistant, has long-term appearance retention, color retention
and texture recovery, is flame-resistant, mildew resistant, and water repellant. Wool is non-allergenic and has
been proven hygienically safe in medically sensitive areas. Wool does not promote the growth of dust mites or
bacteria and actually contributes to air purity in buildings by absorbing polluting gases. (Note: Even natural
carpets can be a source of noxious gases if treated with chemicals. For example, wool carpet is often moth-
proofed; wool carpets are available without moth proofing.)

4-23 Limit use of carpet to one-third of home’s square footage


3 POINTS

The program recognizes carpet’s popularity and function, but suggests the amount of carpeting can be limited.
The healthiest floor choices are smooth surfaces, such as tile, linoleum, and wood, which do not harbor dust and
other allergy-causing particles. Solid surfaces are easier to clean than carpet and they keep vacuuming to a
minimum. (Vacuuming stirs up dust, even under ideal conditions.) Wood and tile floors are also more durable than
carpet, so they cost less per year of use. (See Section Five: Materials Efficiency.)

Resources
See GreenSpec (listed under Resources, Product Information, above) for environmentally friendly alternatives to
carpet.

4-24 If using carpet, install by dry method


1 POINT

Adhesives used to install the carpet to the floor are a significant source of odor and air pollution. Tack strips
eliminate this problem.

Resources
• TacFast is a velcro-like system for installing carpets to the floor without adhesives or tack strips. TacFast
Systems, Richmond Hill, Ontario, Canada, 800-216-0662.
If you use an adhesive, choose a low-odor, water-based product. Never use solvent-based carpet adhesive.
Options include:

• Envirotec Healthguard adhesives by W.F. Taylor, Fontana, CA, 800-397-4583, www.wftaylor.com.

4-25 Optimize air quality in family bedrooms to basic or advanced level


3 POINTS BASIC
5 POINTS ADVANCED
111
Program Note: HRV (see Action item 3-50, Install a Heat Recovery Ventilator) does not qualify as an alternative to
cross-ventilation. Also requirements only apply to family bedrooms, not the whole house.

Basic Level Requirements

• No carpets
• Low VOC/low toxic paints & finishes
• Low toxicity cleaners (construction).
Advanced Level Requirements:

• Install operable windows for cross ventilation


• Install hygrometer/thermometer
• Reduce chances of exposure to EM fields (electronic panels, timers, generators, PV inverters, refrigerators,
large wire chasers)
• Install damp-proof ledges or alcoves
• Provide return ducts or air communication vents to hallways;
• No materials with added urea formaldehyde within bedroom.

Resources
• Neil Kelly Naturals Collection is a line of manufactured cabinets that uses certified woods and veneers as
well as environmentally friendly finishes and case materials. Neil Kelly Signature Cabinets, Portland, OR,
503-288-6345 or www.neilkelly.com.

4-26 Garage air-sealed from house with automatic exhaust fan


5 POINTS

Studies show that carbon monoxide, sometimes produced in significant levels when automobiles are started, can
enter the home from the attached garage. This Action item eliminates this potential source of indoor air pollution
by eliminating the garage altogether or air sealing it from the house with an automatic exhaust fan in the garage.
(Also see Action item 4-77, Install exhaust fans in rooms where office equipment is used).

Air sealing the garage from the house involves:

• Using caulk or foam to seal all holes in walls and the ceiling between the house and garage.
• Using the Airtight Drywall Approach (ADA) in the walls and ceiling shared by house and garage. ADA is an
advanced sealing package that goes beyond basic practice (see Action item 3-15, Airtight Drywall
Approach for Framed Structures).
• Making sure that the door between the house and garage is weather-stripped and is fitted with a
threshold that creates a tight seal with the door.

4-27 Detached or no garage


10 POINTS

Studies show that carbon monoxide, sometimes produced in significant levels when automobiles are started, can
enter the home from the attached garage. This Action item eliminates this potential source of indoor air pollution
by eliminating the garage altogether.

112
4-28 Fully insulate attached garage to minimize condensation-based mold growth
2 POINTS

Insulate to R-9 (R-19 if space is heated) and install insulated garage doors. Garages are typically not insulated
because, unless the space is heated, the cost and materials use will offset any energy and comfort benefits.
However, sources of heat and moist air (refrigerators, freezers, washer and dryer, automobiles, etc.) are often
found in garages. During cool seasons, the temperature differential across an uninsulated envelope may be
sufficient to produce condensation. This might lead to mold growth, potentially resulting in degraded air quality in
the garage and, if attached to the house without proper air sealing, in the home.

4-29 Use urea formaldehyde-free insulation or GreenGuard Certified product


3 POINTS

Standard fiberglass batt insulation, the most common for new houses, has up to 14% formaldehyde, which can
contribute to poor indoor air quality. Look for urea formaldehyde- free fiberglass insulation, or a Greenguard
certified product, preferably one with recycled content ( Action item 5-115, All Insulation to have a Minimum 40%
Recycled-Content). If you use rigid insulation, make sure it is formaldehyde-free, CFC-free, and HCFC-free (See
Action item 5-116, Use Environmentally Friendly Foam Building Products) CFCs and HCFCs are not an indoor air
quality problem, but should be avoided because they are believed to cause deterioration of the earth’s ozone
layer, certainly a general threat to the environment and human safety.

Check conventional product for their claim that the insulation has no added urea formaldehyde or look for a
Greenguard certified product.

Resources
Some environmentally friendly alternatives include:

• Insulsafe II and III fiberglass insulation, Certainteed Corporation, Valley Forge, PA, 800-523-7844, or
www.certainteed.com. Can be purchased through your local supplier.
• Grid-Shield Rx formaldehyde-free fiberglass batts. For information, contact Johns Manville, Inc., Product
Information Center, Denver, CO, 800-654-3103 or www.johnsmanville.com.
For more information about insulation products, see:

• “Insulation Materials: Environmental Comparisons,” Environmental Building News, Jan/Feb 1995,


800-861-0954, www.buildinggreen.com.
Also, see resources for Action item 5-116, Use Environmentally Friendly Foam Building Products
(formaldehyde-free, CFC-free, HCFC-free.

Inside the house, use only low-VOC, low-toxic, water-based, solvent-free sealers, grouts, mortars, caulks,
adhesives, stains, pigments, and additives for:
Conventional construction adhesives, grouts, and mortars used to bond structural components may off-gas large
amounts of toxic VOCs (including solvents and aromatic hydrocarbons). Choose healthier low-VOC options. This
will reduce potential harmful impacts on the health of the occupants as well as installers.

An accepted industry standard for “low-VOC,” is the State of California, South Coast Air Quality Management
District Rule #1168. Based on these guidelines, Table 4-1 provides recommended limits for VOCs in adhesives

Table 4-1 Recommended Limits for VOC’s in Adhesives


(in grams per liter, less water and Exempt compounds)
(Source: State of California, South Coast Air Quality Management District Rule #1168, Amended January 2005)

Current VOC Limit

113
Indoor Carpet Adhesives 50
Carpet Pad Adhesives 50
Outdoor Carpet Adhesives 150
Wood Flooring Adhesive 100
Rubber Floor Adhesives 60
Subfloor Adhesives 50
Ceramic Tile Adhesives 65
VCT and Asphalt Tile Adhesives 50
Dry Wall and Panel Adhesives 50

Table 4-2 Recommended Limits for VOC’s in Sealants


(in grams per liter, less water and Exempt compounds)
(Source: State of California, South Coast Air Quality Management District Rule #1168 Amended January 2005)

Sealants Current VOC Limit


Architectural* 250
Nonmembrane Roof 300
Single-Ply Roof Membrane 450
Other 420
*Architectural Sealants refer to the use of an adhesive, sealant, or adhesive or sealant primer on stationary
structures and their appurtenances, including, but are not limited to: hand railings, cabinets, bathroom and
kitchen fixtures, fences, rain gutters and downspouts, and windows.

Resources
General Information on alternatives:

• Greenguard Environmental Institute, Indoor Airy Quality Certified third-party certification program, listing
low emitting interior building materials, furnishings, and finish systems. On-line product search available
at www.greenguard.org, 800-427-9681 or email info@greenguard.org.
• Austin Energy Green Building Program, 2006, Sustainable Building Sourcebook Chapter: Health and
Safety, has a good listing of product suppliers,
http://www.austinenergy.com/Energy%20Efficiency/Programs/Green%20Building/Sourcebook/index.htm
Options include:

• Auro Cold Casein Wood Glue, Sinan Company, Davis, CA, 530-753-3104, or
www.dcn.davis.ca.us/go/sinan/productguide.html. Also make a line of natural, all-purpose floor adhesives.
• Envirotec, a line of low-toxic flooring and multi-purpose adhesives, W.F. Taylor, Fontana, California,
800-397-4583, www.wftaylor.com.
• D-50 Plus Mortar and D-40 Latex Fortified Mortar, low-toxic mortars from DAP, Inc., Baltimore, MD, 1-
888-DAP-TIPS.
• Latapoxy SP-100 low toxic grout, epoxy grouts, and thin-set mortars, Laticrete International, Bethany, CT,
800-243-4788, www.laticrete.com.
• PL Premium Wood Glue and other low-toxic adhesives, ChemRex (makers of Sonneborn Products),
Shakopee, MN, 800-433-9517, www.chemrex.com.
• Safe-Set, a line of solvent-free, low odor, professional quality adhesives by CHAPCO (Chicago Adhesive
Products Co.), 800-621-0220.
• Safecoat Grout Sealer, 3-in-1 Adhesive, Tile Grout and Caulking Compound, AFM Enterprises, San Diego,
CA, 619-239-0321, www.afmsafecoat.com.
• Titebond Solvent-Free Construction Adhesive, Franklin International, Columbus, OH, 800-669-4583,
www.titebond.com

114
• Miracle, Kingco water-based duct sealants used for permanently sealing the fabricated joints and seams of
air duct system, are Greenguard Indoor Air Quality Certified, http://www.itwtacc.com/hvac.html.
• Murco, a joint compound formulated with inert fillers and natural binders; no preservatives or slow
releasing compounds www.murcowall.com

4-30 Tile and grout


2 POINTS

Thin-set adhesives and mortars are available with Greenguard certifications. Also anti-microbial grout admix, and
sanded and unsanded cement grout come with Greenguard Indoor Air Quality certifications

4-31 Framing
2 POINTS

For framing products, such as caulks and adhesives, choose low VOC and/or low-toxic alternatives.

4-32 Flooring
4 POINTS

If you choose to finish materials on site, make sure the adhesives, sealers, stains, and finishes are all low-VOC,
low-toxic, water-based, and/or solvent-free. Pre-Finished floors DO NOT qualify for this credit. This credit only
applies to site-applied finishes.

4-33 Plumbing
2 POINTS

When installing plumbing fixtures, choose credit-compliant sealers and caulks.

4-34 HVAC
2 POINTS

The HVAC system requires duct sealants and caulks; choose credit compliant mastic and caulks.

4-35 Insulation
2 POINTS

Credit for this Action items refers to insulation in the building envelope, not for duct work – credit for duct work is
given above. To prevent air infiltration using rigid foam insulation, you will need to seal the seams with caulk or
tape. Use credit compliant caulk for the best in indoor air quality and envelope sealing.

4-36 Drywall
2 POINTS

For drywall mud, look for products that do not add biocides. Biocides include pesticides, poisonous heavy metals,
and other preservatives that prevent materials from spoiling. Some biocides may off-gas just as VOCs do, and can
cause reactions in chemically sensitive people. Use credit-compliant sealers, caulks, and pigments in any finish
paints
115
4-37 Use materials without added urea-formaldehyde for finish work, including
shelving, window and door trim, and base molding
2 POINTS

Formaldehyde in the indoor environment can cause health problems for occupants, including headaches and flu
like symptoms, and sick building syndrome. Some shelving, window trims, door trim, base molding, and other
interior trim and wood products may also use urea-formaldehyde glue as a binder. With an off-gassing half-life of
about 10 years, urea-formaldehyde continues to off-gas formaldehyde for a long time after application.

A series of specialty MDF products are certified by Scientific Certification Services (SCS) for up to 100% recovered
and recycled wood fiber content and for having no added formaldehyde (lab tested to 0.05 ppm). The products,
Medex, Medex NC, Medite II and Medite FR, are manufactured using polyurea resin in place of the urea-
formaldehyde resin commonly used in MDF and particleboard, and can be used for these applications. Some
finish contractors do not like working with MDF products for trim and molding applications because it is so brittle.
Consider MDF for flat trim areas such as mantles, wall panels, and wainscoting. Plaster options are also available.

4-38 Use plywood and composites of exterior grade or with no added urea
formaldehyde (for interior use)
3 POINTS

Particleboard, interior grade medium density fiberboard (MDF), and other interior use, glue-containing products
use urea-formaldehyde glue as a binder. With an off-gassing half-life of about 10 years, urea-formaldehyde
continues to off-gas formaldehyde for a long time after application. Formaldehyde in the indoor environment can
cause a several health problems for the occupants, including headaches and flu like symptoms, and can be a cause
of sick building syndrome.

Instead, use materials containing no formaldehyde, such as Medex grade MDF, whenever possible. Or use
products with exterior grade glue, which use phenyl formaldehyde glue. Phenyl formaldehyde glue off-gases
quickly, and most formaldehyde is gone before the product reaches the jobsite. Exterior grade products include
most plywoods and OSB currently available.

Resources
• SkyBlend, SCS and EPP certified to be 100% pre-consumer recycled wood fiber particleboard with no Urea
Formaldehyde added during the manufacturing process. For use in any particleboard application such as,
shelving, countertops, cabinets, millwork, furniture. Roseburg Forest Products, Dillard, OR, 800-245-1115,
www.rfpco.com/particleboard/skyblend.htm
• Medex and Medite II MDF, formaldehyde-free alternatives for underlayment, cabinet frames, countertops,
interior door and window casings, and trim. Medex is water-resistant, Medite Corporation, Medford, OR,
541-826-2671. Available through local suppliers.
• FIBEROCK Brand Gypsum Fiber Underlayment is a fiber-reinforced gypsum panel specially designed for
use in residential construction as an underlayment for vinyl, carpeting, hardwood flooring, and ceramic tile
(dry areas only). Manufactured by U.S. Gypsum Co., 800-874-4968, www.usg.com.

4-39 Install cabinets made w/ no-added urea formaldehyde board and low-toxic finish
3 POINTS

Cabinets are often built from particleboard, which off-gasses formaldehyde for a long time (See Action item 4-38,
Use Plywood and Composites of Exterior Grade or with No Added Urea Formaldehyde (for Interior Use).) Instead,
purchase cabinets made from a material with no added urea formaldehyde, such as Medex grade MDF, solid
116
wood, or plywood, which adds very little additional cost to the overall cabinet budget. Cabinets should be finished
with a low toxic finish.

Resources
• Neil Kelly Naturals Collection is a line of manufactured cabinets that uses certified woods and veneers as
well as environmentally friendly finishes and case materials. Neil Kelly Signature Cabinets, Portland, OR,
503-288-6345 or www.neilkelly.com.

4-40 Use ceramic tile for 5% or more of flooring


2 POINTS

For a typical 2000 sf house, 5% = about 100 sf. Considering that typically one bathroom is 25 sf, this is an easy
credit to add to any house design.

Ceramic tile floors usually pose very little health risk on a day-to-day basis. Because they are more durable than
carpet, they also cost less per year of use. During installation, make sure you use low-toxic grout (Action item 4-
30, Inside the House, Use Only Low-VOC, Low-Toxic, Water-Based, Solvent-Free …) and keep the workspace
well-ventilated.

Note: Avoid the use of imported tile. The glazing used on imported tiles can contain lead. Recycled content tiles
are also available. See Action item 5-69, Use 40% Recycled-Content Hard Surface Tile, 100 Square Feet Minimum, for
recycled-content credit.

Resources
Consult with local suppliers. See also resources for Action item 5-69, Use 40% Recycled-Content Hard Surface Tile.

4-41 Use polyethylene piping for plumbing and electrical conduit. No PVC piping
3 POINTS

Some studies indicate that use of PVC plastics in the home is related to increased incidence of bronchial
obstruction (asthma) in children (source: American Journal of Public Health. 1999; 89:188 & SHY;192). Also, in the
event of a fire, PVC can release toxic smoke. If the water is slightly acidic or alkaline, copper plumbing can release
copper ions into drinking water, which is potentially harmful to health.

Instead, use polyethylene piping for plumbing.

Resources
• AQUAPEX polyethylene tubing, WIRSBO, Apple Valley, MN, 800-321-4739 or www.wirsbo.com.

4-42 Use low- or non-VOC and non-toxic interior paints and finishes on large surface
areas or all interior surfaces
3 POINTS FOR LARGE SURFACE AREAS
5 POINTS FOR ALL INTERIOR SURFACES

Solvent-based paints are traditionally considered the most durable, but they produce toxic emissions when curing
and require the use of hazardous solvents for cleanup. In addition, they off-gas trace amounts of volatiles (gases)
for months following application, which can cause upper respiratory irritation to the occupants.

“Zero-VOC” or low-VOC water based paints are generally safer to handle, can be cleaned up with water, and
produce little or no off-gassing. For most indoor applications, there is almost no difference in performance

117
between solvent-based and water-based paints. Many low-VOC paints are comparable in price to conventional
paint.

Paints and Finishes VOC Limits:

The VOC concentrations of the product shall not exceed

• 150 (VOC weight in grams/liter of product minus water) for Non-Flat paint,
• 50 (VOC weight in grams/liter of product minus water) for Flat paint for interior paints.
You must use paints and finishes that meet these requirements, note that GreenSeal products meet these
standards.

Choose your colors carefully, as well, since darker colors inherently have higher VOC content because of the
pigments added.

Low-VOC, water-based paints may still contain toxic ingredients, however. Although
these toxic ingredients are not generally an air quality problem for occupants, they may be
hazardous to painters and those involved in manufacture of the paint. In addition,
hazardous ingredients can degrade the natural environment during production and after
disposal. They may also leave an odor for a much longer period. Fortunately, several
locally available, water-based paints perform well and are low-toxic, that is they do not
contain heavy metals or organic compounds. These paints tend to cost 5% to 20% more
than most conventional paints.

Low-toxic, clear sealers are also available to use as finishes for woodwork. Water-based varnishes, polyurethanes,
and other finishes for hardwood floors are very durable and much safer to handle than traditional products.
Low-toxic solvents, water-based strippers, and all-natural thinners are also locally available.

Resources
Most suppliers have a good selection of low-VOC products. You have to ensure the low_VOC paint is also low
toxic.

• GreenSeal, Green Seal follows the Guiding Principles and Procedures for Type I Environmental Labeling
adopted by the International Organization for Standardization (ISO 14024).,
http://greenseal.org/index.cfm.
Some product alternatives to look at include:

• Safecoat line of paints and finishes from AFM, San Diego, CA, 619-239-0321. They also offer enamels,
exterior stains, and interior transparent finishes.
• American Pride line of paints GreenSeal Certified, from Southern Diversified, Hattiesburg, MS, 601-264-
0442. They also offer enamels, exterior stains, and interior transparent finishes.
• Best Paints, low-toxic latex paints from Best Paint Company, Seattle, WA, 206-783-9938.
www.bestpaintco.com.
• Concure, a clear, environmentally safe concrete sealer, Edgemont, PA, 800-925-7746.
• CURATOR Commercial Waterborne Finish. Preferred Products, Inc., Seattle, WA, 800-774-0034. It is an
easy-to-use, two-component, 100% urethane waterborne finish designed especially for high wear
residential and commercial applications.
• Enviro-Cote by Kelly-Moore. Available from Kelly-Moore in Seattle, 206-763-0300, www.kellymoore.com.
The website has a store locator.
• Interior Health Spec, zero-VOC paint, Sherwin Williams Co., Cleveland, OH, 800-336-1110,
www.sherminwilliams.com.

118
• Miller Low-Biocide Paint, with preservatives and fungicides removed. Miller Paints, 503-255-0190,
www.millerpaint.com
• Pristine, from Benjamin Moore & Co., Montvale, NJ, 888-236-6667, www.benjaminmoore.com.
• Horizon Clean Air Select paints from Rodda Paints, LLC.
• Spread 2000 and Lifemaster 2000, zero-VOC paints, ICI Dulux Paints, (formerly Glidden), 800-984-5444,
www.gliddenpaints.com. Available at ICI Paint stores, in over 70 colors.
• Tried & True, an old-fashioned, boiled linseed oil waterproof finish that is all natural and food-safe, New
York, 607-387-9280.
• 3-M Safe Strip is one of the least toxic strippers available.

MOISTURE CONTROL
Moisture that enters the home through the foundation walls and floor can lead to problems such as mold growth
and can contribute to a variety of health problems for the homeowner. Specific construction techniques and
materials can eliminate moisture.

The following provide resources for multiple aspects of moisture control in residential construction:

Resources
• Builder’s Guide, by Joe Lstiburek (listed in Resources, Technical Books and Guides, above).
• Moisture Control Handbook: Principles and Practices for Residential and Small Commercial Buildings by
Joseph Lstiburek and John Carmody (listed in Resources, Technical Books and Guides, above).
• “Energy Ideas Clearinghouse.” The EIC will provide customized responses to specific questions moisture
control. (See General Resources, above.)
• www.buildingscience.com -- This site offers useful information regarding moisture control is emphasized.
(See General Resources, above.)

4-43 Slope crawlspace and foundation grade toward perimeter for drainage, supply
drainage lines out to exterior footing drains, and install polyfilm vapor barrier
sealed to stem walls
1 POINT

Stormwater that stands or seeps around crawlspace, slab, foundation, or basement can lead to moisture damage,
dampness, and mold growth. Backfilled dirt around the footprint of a building should slope down and away for a
distance of at least 5 feet to ensure surface runoff away from structure. Down spouts should feed into infiltration
trenches or other drainage systems that convey water away from footings. Garage floor and driveway are sloped
to drain out. See Action item 2-7, Use an alternative foundation system that minimizes volume of foundation
material and disturbance to soil and/or to water flow, for at least 50% of the foundation.

4-44 Verify seal at doors, windows, and plumbing and electrical penetrations against
moisture and air leaks
1 POINT

Sealing these penetrations is required by code but often difficult to enforce. As part of quality control, ensure your
crew seals all penetrations at doors, windows, plumbing and electrical penetrations.

Pay special attention to plumbing stacks that run from the crawlspace to the attic, adjacent to baths and kitchen.
Leaky pathways in these locations act as chimneys, continuously drawing cool air from the crawlspace to the attic.

119
During winter months especially, the cold air drawn through rooms with high relative humidity cools interior
surfaces and promotes condensation and mold growth.

Even better, use the Airtight Drywall Approach (ADA), an advanced sealing package that goes beyond basic
practice (see Action item 3-15, Airtight Drywall Approach for Framed Structures). See the Resources section for a
reference the Energy & Environmental Building Association Builder’s Guide for Mixes Humid Climate Type for
extensive information on air sealing techniques.

Resources
See resources listed for Moisture Control above.

4-45 Envelope inspection at pre-insulation by a qualified professional


3 POINTS

A pre-Insulation Inspection is designed to ensure that all air leakage elements of the building shell have been
addresses. The inspection should cover air sealing, such as, air tight recessed cans, building envelope penetrations
are sealed, chases are capped and sealed; insulation and windows, such as basement walls insulated properly, roof
vented properly, windows sealed; heating and cooling systems, such as ducts are supported and run properly,
ducts stay out of insulated cavities; and moisture management and IAQ, such as having all fireplaces with flues
and inlets.

A Qualified Professional is someone who specializes in air sealing inspections. See the Resources Section for more
information.

4-46 Slab on grade, upgrade under slab moisture barrier beyond code to 10 mil
minimum; minimum of 10 mil poly in crawl spaces with sealed seams and sealed
perimeter
2 POINTS

If a slab is installed, use gravel fill beneath the foundation slab with a poly membrane (min. thickness of 10 mm) or
vapor retarder, sealed over the gravel prior to pouring the basement floor. Seal the poly at the edges and seams to
prevent moisture from migrating into the home. Taped and sealed foam under the entire slab also applies for this
credit. (Note: The poly barrier also protects against radon and other soil gases. However, soil gases are generally
not a problem in western Washington.)

If no slab is used, bottom of floor structure should be at least 12 inches (1 foot) above backfilled dirt.

Resources
See resources listed for Moisture Control above.

4-47 Install approved ice and water shield membrane for roofs pitched under 4-in-12
1 POINT

4-48 Roof overhangs are at least 24” inches


3 POINTS

Appropriately sized roof overhangs provide and energy benefit, see Action item 3-30, Passive Solar Design, Basic
Features. They also provide a moisture control benefit in that they help protect the home from moisture damage
caused by precipitation. When designing the structure take both the energy and moisture control benefits into
account to obtain the best results.
120
For out climate, minimum roof overhangs are recommended to be 18”, however, this recommendation does not
account for wind-driven rain, a condition that varies with local climate or site exposure. Specifying 24” overhangs
affords more protection for the wall system.

Resources
See General Resources above for PATH, http://pathnet.org/, search roof overhangs.

4-49 Protect windows and doors on tall walls with additional overhang protection
2 POINTS

Consider using larger overhangs, over 24 inches, for overhangs protecting more than two stories of walls with
exposed windows and doors. Beyond contributing to reducing the moisture penetration on exterior and
foundation walls, this strategy also protects the door’s finish from moisture around jambs, trim, and thresholds.
Success of the larger overhangs is dependent on having the walls properly constructed with a weather barrier,
roofs that are adequately guttered, and a maintenance plan for the exterior.

Resources
See resources listed for Moisture Control above.

4-50 Use a nontoxic foundation, dampproofing treatment and perimeter drain to


protect walls against moisture
2 POINTS

4-51 Install a drainable house wrap under exterior siding to promote wall drainage.
1 POINT

Drainable House Wrap: A Drainable House Wrap is defined as any properly installed house wrap that is engineered
to have a minimum drainage efficiency of 90% measured in accordance to ASTM E2273 – Determining the
Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies. Because this is the
criteria used to establish drainage by ICC-ES (International Code Counsel – Evaluation Service) Acceptance Criteria
AC-24 – Interim Criteria for Exterior Insulation and Finish Systems, house wraps with a code report showing this
evaluation are acceptable.

A Drainable House Wrap should not be confused with a “Rain Screen” system. A properly installed “Rain Screen”
system, will fir your exterior cladding a minimum of 3/8” away from the exterior sheathing. The benefits of a “Rain
Screen” System are: Drainage, Depressurization of the wall and Ventilation of the wall cavity. A Drainable
Housewrap does not ventilate or depressurize a wall, but it will provide Drainage. Drainage is particularly
important when working in High Wind Pressure areas or when installing Cedar, Manufactured Stone, EIFS or
Stucco claddings. In order to achieve drainage with manufactured stone and stucco claddings a secondary,
sacrificial water resistive barrier must be installed.

Points can not be combined for having a Drainable House Wrap and a Rain Screen system.

4-52 Full exterior drainage plane integrated shingle-style with pan-flashed and face-
flashed door and window openings, as designated in EEBA's "Water Management
Guide", or equivalent
5 POINTS

121
4-53 Install a sloped sill pan with end dams and back dams for all windows, and back
dams for all exterior doors exposed to the weather
5 POINTS

Window perimeters should have flashings (sill, jambs and head) that are integrated with the waterproofing at
adjacent walls. Self adhered membrane flashing as well as metal.flashing are acceptable strategies for preventing
water ingress. Slope head and sill flashings to the exterior for prompt drainage. Many windows leak at sill-to-jamb
corners. To collect this leakage and drain it to the exterior, sill flashings with a panned up interior leg and end
dams are required. Do not penetrate the horizontal portion of the sill flashing with window fasteners. Instead,
where attachment of the sill frame is required, provide an attachment angle inboard of the window sill and fasten
through the upturned leg of the sill flashing into back of the sill frame.

New products are also available that offer greater performance than traditional entry door and window flashing.
Sloped sill pans feature durable synthetic construction, sloped surface, integral drainage feature, lock-in end caps
and are cuttable to desired lengths. Other products include a one-piece sill drain mat that installs under the
windows on the rough opening.

Resources
• Pan Flashing/Sill Protection Installations Effective in Reducing Water Intrusion, April 2006, NAHB Research
Center, Inc,.400 Prince George’s Blvd., Upper Marlboro, MD, see Appendix E, Manufacturer/Product
Survey Matrix, http://www.toolbase.org/Newsletters/News/tbn-spring2006#2 or
http://www.toolbase.org/PDF/CaseStudies/PanFlashingReport.pdf
• Suresill Sloped Sill Pan, www.suresill.com/home.html

4-54 Install metal flashing at all windows and all door heads exposed to the weather
1 POINT

Flashing must be durable, weather resistant, able to accommodate movement, and compatible with adjacent
materials. The traditional overlapping assembly composed of multiple layers of flashing adjusts to movement like
the scales of a fish and provides repetitive layers of resistant materials while covering the fasteners with each lap.
Overlapping the material below prevents water from migrating in opposition to the forces of gravity when an
unequal pressure condition exists, as in high wind storms. The longer the lap the greater the force required to
draw the water upward.

Non-corrosive metals such as copper, aluminum, and lead are popular flashing materials because of their
durability, malleability, and impervious nature. Sheet metal and vinyl flashing are appropriate for traditional
assemblies of lapped materials. New continuous drainage barriers employ self-adhering membrane and tape
materials to work in conjunction with doors and windows with integral nailing fins.

4-55 Hose-test installed windows, before siding, to verify resistance to wind driven
rain
3 POINTS

This test is designed to verify the performance of the first installed window. Use the first installed window, once
fully installed with all appropriate flashing and sealing into the wall system as the test case. The window is factory-
tested, but job-site installation can lead to potential water and air leakage into the building assembly. For
instance, joints between windows and walls may not have been properly sealed, nor may there have been proper
sealing to the adjoining cladding.

122
The best site test available to check for watertightness is to take a hose and spray the first installed window and
check for water penetration. Correct any improperly sealed areas and retest.

4-56 Where not required by code, install working radon type vent system to eliminate
potential moisture, methane, and radon problems in crawl space or under slabs
on grade
2 POINTS

THIS ACTION ITEM IS NOT APPLICABLE TO AREAS WHERE RADON SYSTEMS ARE ALREADY REQUIRED BY
CODE.

Figure 4-1 Washington State - EPA Map of Radon Zones

Zone 1 counties have a predicted average indoor radon Highest Potential


screening level greater than 4 pCi/L (picocuries per
liter) (red zones)

Zone 2 counties have a predicted average indoor radon Moderate Potential


screening level between 2 and 4 pCi/L(orange zones)

Zone 3 counties have a predicted average indoor radon Low Potential


screening level less than 2 pCi/L (yellow zones)

IMPORTANT: Consult the publication entitled "Preliminary Geologic Radon Potential Assessment of Washington"
(USGS Open-file Report 93-292-J) before using this map.http://energy.cr.usgs.gov/radon/grpinfo.html This
document contains information on radon potential variations within counties. EPA also recommends that this
map be supplemented with any available local data in order to further understand and predict the radon potential
of a specific area.

123
There are two types of sub-slab depressurization radon systems: passive and active. A passive system prevents
radon from entering the home by using barriers placed during construction, and it allows radon to leave the house
using the home's own natural airflow and pressures and a carefully placed pipe. An active system uses the same
barriers and pipe but also adds a mechanical fan to proactively remove radon from the home. The configuration of
a radon system will vary with the design of the home — namely, the foundation type.

All passive systems, regardless of foundation type, should have the same basic features:

• A gas permeable layer under the home, such as a layer of gravel, to allow gas to move freely under the
home
• Plastic sheeting installed over the gas permeable layer to prevent the gas from entering the home
• A vent pipe that directs gas up and out over the home, rather than into it
• Sealing and caulking around all openings in the foundation floor to prevent gas from leaking into the
home
• A junction box in case an active system must be installed later
In addition to these features, an active system will have a small in-line fan at the end of the vent pipe to
mechanically draw the gas out.

The same technology for mitigating radon exposure in homes, is used to keep moisture away from and out of the
house. Depending upon type of foundation (basement, slab, or crawlspace), active system options include:

• Mechanically Ventilated Crawlspace System—The system uses a fan to increase ventilation within a
crawlspace, achieve higher air pressure in the crawlspace relative to air pressure in the soil beneath the
crawlspace or achieve lower air pressure in the crawlspace relative to air pressure in the living spaces.
• Sub-Membrane Depressurization System—This system vents air/moisture from under a
soil-gas/moisture-retarder membrane by either using a fan-powered vent (active system) or vent pipe
routed through the conditioned space of a building and connecting the sub-slab area with outdoor air
(passive). The latter relies solely on the convective flow of air upward in the vent to draw air from beneath
the slab.

Resources
• Model Standards and Techniques for Control of Radon In New Residential Buildings, a EPA publication
available online at www.epa.gov/iedweb00/radon/pubs/newconst.html

4-57 Install a rigid perforated footing drain at foundation perimeter, not connected to
roof drain system
1 POINT

Depending on the soil type, install perforated footing drainage along the foundation perimeter and tie them into
an appropriate drainage at least 5’ from the house to help control moisture in the house. Check with your local
jurisdiction. Soils report identifies degree of backfill compaction plus minimum slope toachieve adequate
drainage.

Perforations point down to allow water to enter the drainpipe. Drain discharges by gravity (preferable) or
mechanical means into the approved drainage system.

Resources
• The Building Science Corporation website www.buildingscience.com. This website site offers useful
information, emphasizing moisture control. (See General Resources, above.)

124
4-58 Show and build moisture management details for below grade walls beyond
code, such as dimple drainage mat at exterior face and capillary breaks
3 POINTS

Detail a moisture management system for below grade walls that go beyond code.

Best practices indicate that there are six elements of waterproofing below grade walls:

• Slope surface soil away from the structure.


• Install roof water management system that keeps water away from basement walls.
• Install a waterproof barrier, either roll membrane or liquid-applied membrane from 6” above final grade
down to and onto the die of the footing or slab.
• Install a perforated footing drain around perimeter of foundation, and cover with geotextile filter fabric.
• Install dimple drainage mat on exterior face of waterproofing membrane to provide protection for the
membrane and over top of the footing drain and drain rock. The dimple drainage mat provides an air
channel for water to be carried by gravity to the footing drain
• Finally, backfill with native soil if dimple board air barrier with a filter fabric has been installed.
Another practice in protecting the home from water moving up into the foundation is the use of capillary
breaks. A capillary break is created using either an elastomeric asphalt coating or a polyethylene sheet. On
the vertical face of the foundation (exterior walls) be sure to clean the surface and fill any cracks or gaps larger
than 1/8" wide. Spray on a coat of elastomeric asphalt starting 4" from the ground and completely covering
the surface to the top. Place a capillary break between the footing and the foundation wall. This can be done
by spraying the footing with an elastomeric asphalt coating or by covering the footings with a polyethylene
sheet.

Resources
• The Building Science Corporation website www.buildingscience.com. This website site offers useful
information, emphasizing moisture control. (See General Resources, above.)

4-59 Perform calcium chloride moisture test on all slabs on grade prior to installing any
finish flooring in conformance with product warranties
2 POINTS

The calcium chloride vapor emission test quantifies the volume of water vapor radiating from a concrete slab
surface. Kits are available locally. Conducting this test can help prevent expensive callbacks and may be required
by many warranties for floor covering installations.

Resources
• wwww.vaportest.com

4-60 Have crawl space, attic, and garage building performance tested for
disconnection to the living space of house
3 POINTS

To ensure indoor air quality integrity of the living space, it is best to have the crawl space, attic, and most
definitely, the garage, fully sealed from the living space for moisture and air.

125
Use Blower Door Test and/or Duct Blaster tests to verify performance. See Action items, 3-16, Blower Door Test…

4-61 Use an unvented or mechanically-exhausted, conditioned crawl space (not


appropriate where flood venting is required)
3 POINTS

Unvented, conditioned crawl spaces perform better than vented crawl spaces in terms of safety, health, comfort,
durability and energy consumption. Conditioned crawl spaces also do not cost more to construct than vented
crawl spaces. (Unvented crawl spaces are not appropriate for flood zones, where flood venting is required).

The International Residential Code allows for the construction of “conditioned” crawl spaces. For further
information on crawl space design and code requirements, review the technical article at:
http://www.buildingscience.com/resources/foundations/conditioned_crawl.pdf

Unvented, conditioned crawl spaces with insulation on the perimeter perform better in terms of safety and health
(pest control), comfort (warm floors, uniform temperatures), durability (moisture) and energy consumption than
passively vented crawl spaces with sub floor insulation.

Perimeter insulation, rather than floor insulation, performs better in all climates from an energy conservation
perspective. The crawl space temperatures, dew points and relative humidity track that of the house. Crawl spaces
insulated on the perimeter are warmer and drier than crawl spaces insulated between the crawl space and the
house.

Crawl spaces should be designed and constructed as mini-basements, part of the house – within the conditioned
space. They should be insulated on their perimeters and should have a continuous sealed ground cover such as
taped polyethylene. They should have perimeter drainage just like a basement when the crawl space ground level
is below the ground level of the surrounding grade.

4-62 No plumbing distribution lines in exterior walls


4 POINTS

4-63 Implement mold prevention measures such as antimicrobial treatment


4 POINTS

AIR DISTRIBUTION AND FILTRATION

Resources
• Understanding Ventilation: How to Design, Select, and Install Residential Ventilation Systems, by John
Bower. Available from the Journal of Light Construction Bookstore, 800-859-3669 or
www.constructionbookstore.com.
• Healthy House Building: A Design and Construction Guide (listed in Resources, Technical Books and Guides,
above). Good information on optimizing air distribution and ventilation.
See your local building materials or heating supplier for improved filters. For quiet fan options, see resources
listed under Action item 4-77, Install Exhaust Fans in Rooms Where Office Equipment Is Used.

126
4-64 Verify performance of ventilation systems; measuring supply and exhaust airflow,
checking control activation and damper operation
3 POINTS

This Action item requires a third party to verify proper operation of ventilation systems by measuring the air flow
of all supply and exhaust systems using a flow hood. Also check controls for proper activation. Check mechanical
damper operation, if applicable.

4-65 Install return-air ducts or passive pressure-relief strategy in all bedrooms


3 POINTS FOR INSTALLING RETURN-AIR DUCTS IN ALL BEDROOMS
5 POINTS FOR PASSIVE-PRESSURE RELIEF STRATEGY IN ALL BEDROOMS

The most important area of the house to optimize the indoor air quality is in the bedrooms, by eliminating toxic
finishes, dust, and/or moisture‑prone surfaces in these rooms. This is because we spend the most time there. The
installation of return air ducts to every bedroom ensures an adequate supply of fresh air to sleeping areas.

Optimizing air quality in sleeping areas is one example of “air quality zoning,” a strategy that recognizes that
different rooms have different functions and air quality control requirements. Another example is isolating air
distribution systems serving hobby rooms and office areas, which produce odors, from the rest of the home.

4-66 Use medium-efficiency pleated filter, MERV 10


1 POINT

When purchasing filters, look for the highest efficiency filter that works with your furnace. Filter efficiency is
based on the Minimum Efficiency Reporting Value, or MERV. MERV ratings are usually listed on the product
packaging. Look for the highest MERV ratings as possible, since this industry standard rating system measures
the ability of the filter to trap particulates.

Medium efficiency pleated filters filter air through an extended surface area (pleating) to remove between 40%
and 50% of all particulate matter. They are relatively inexpensive and sufficient for most home applications. Look
for product with a minimum of 10 MERV rating.

Resources
Medium-efficiency pleated filters:

• Camfil Farr Company, http://www.camfilfarr.com/cou_us/.


• Honeywell, Inc., Golden Valley, MN, 800-328-5111 or 800-345-6770, www.honeywell.com.
• Purolator Products Air Filtration Company, Henderson, NC, 252-492-1141, http://www.purolatorair.com/.
• General Filters, Inc., Novi, MI, 248-476-5100, www.generalfilters.com.
• Research Products Corporation, Madison, WI, 800-334-6011, www.resprod.com.
• Smith Filter Corporation, Moline, IL, 309-764-8324, www.smithfilter.com.
• Trion, Inc., Sanford, NC, 919-775-2201, www.trioninc.com.

4-67 Use high-efficiency pleated filter, MERV 12 or better, or HEPA


5 POINTS

127
High efficiency pleated filters with a MERV of 12 or better are available on the market. Since the MERV rating is
higher, so is the filter efficiency.

More efficient filters, such as HEPA (high efficiency particulate air) filters, remove 99% or more of all particulate
matter in the air. They are expensive, have high flow resistance and may require custom design for home
applications. However, because of its high efficiency at filtering out tiny particulates, HEPA filtration is
recommended for those individuals who suffer from allergies, asthma, or other respiratory problems. The
filtration system connects in-line with the furnace ductwork and offers three stage filtration. An anti-microbial
polyester pre-filter with a five pound, activated carbon filter is attached to the filtration system. For these
reasons, they are not commonly used in residential filtration at this time.

Make sure you include information about the air filter system you choose (including filter size, type, quality, and
the ideal replacement schedule) in the Homeowner’s Kit so homeowner can properly maintain it (see Action item
6-1, A building owners’ manual is provided).

Resources
HEPA filters:

• CWR Environmental Products, Inc., Glen Cove, NY, 800-444-3563 http://www.cwrenviro.com/.


• Honeywell, Inc., Golden Valley, MN, 800-328-5111 or 800-345-6770, www.honeywell.com.
• Purolator Products Air Filtration Company, Henderson, NC, 252-492-1141.
• Shelter Supply, Lakeville, MN, 800-762-8399, www.shelter-mn.com.
• Trion, Inc., Sanford, NC, 919-775-2201, www.trioninc.com.

4-68 Balance airflow system based on filter being used


2 POINTS

All filters pose added resistance to airflow. Make sure the filter is installed in the system prior to final ventilation
system balancing, and ensure system is installed according to Air Conditioning Contractors of America (ACCA)
manual J specifications.

4-69 Install central vacuum, exhausted to outside


3 POINTS

Central vacuum systems provide cleaner indoor air by efficiently removing particles without stirring up
microscopic dust particles and re-emitting them into the home’s interior. The vacuum receptacle is usually vented
outside of the living space, so dust isn’t blown about the house. They do not have particularly efficient filters,
however, so make sure the outdoor exhaust isn’t directed into a basement or located near a fresh air inlet.

If adding a central vacuum, locate it in the garage and exhaust it to outside (but not near a fresh air inlet). Make
sure the garage is air sealed from the livings spaces or other unconditioned space. (see Action items 4-27,
Detached or No Garage, or 4-26, Garage Air-Sealed from House with Automatic Exhaust Fan).

Resources
Central vacuum manufacturers include:

• Beam Industries Inc. (makes one of the quietest central vacuums), Webster City, IA, 800-369-2326,
www.beamvac.com.
• Broan-NuTone, Hartford, WI, 800-558-1711 or www.broan.com.
• Electrolux, Atlanta, GA, 800-243-5893, www.electrolux.com.

128
• HP Products, Inc. (manufacturer of the VACUFLO), Louisville, OH, 800-VACUFLO 800-822-8356, ext. 252 or
www.vacuflo.com.
• M.D. Manufacturing Company, Bakersfield, CA, 800-525-2055 or www.builtinvacuum.com.

4-70 Provide for cross ventilation using operable windows


2 POINTS

Strategically placed operable windows promote indoor air quality by providing a means to bring fresh air into the
home and exhaust stale air. Open floor plans with a minimum of interior partitions improve air circulation through
the home.

Generally, natural cross ventilation is obtained by locating window openings in opposing walls and in line with
each other. By having windows in both sides of a room, positive pressure on the inlet side and/or a vacuum on the
outlet side of the building cause air movement provided that windows on both sides of the room are open. Use
smaller window openings for the inlets and larger openings for the outlet. This increases the air speed and
improves the cooling effect.

4-71 Install an operable skylight, clerestory or roof monitor (manual or automated)


high up in the structure to aid natural ventilation. Use U-factor of 0.45 or below
and solar gain co-efficient of 0.35 or below for skylight
2 POINTS

An operable skylight can be used to create controlled natural ventilation, allowing warm air that has risen to the
top of the house to escape, and drawing up cool air from below. However, skylights can be a source of unwanted
solar heat gain and/or thermal loss, so location should be carefully selected, and the benefits weighed against the
disadvantages.

Operable clerestory windows in an upper wall or a roof monitor could also qualify.

4-72 Use ultraviolet light or equivalent new technologies for air purification
2 POINTS

4-73 A carbon monoxide (CO) alarm is installed in a central location outside of each
separate sleeping area in the immediate vicinity of the bedrooms. The alarm is
hardwired with a battery back-up.
3 POINTS

Carbon monoxide (CO) is produced by incomplete combustion of materials such as natural gas, wood, coal, oil,
kerosene, gasoline, and even tobacco. Sources include wood or gas burning stoves and fireplaces, automobile
exhaust from attached garages, and contamination from furnace flue leaks and backdrafting. At low levels, CO
causes fatigue in healthy people and chest pains in those with heart disease. At higher levels, symptoms range
from impaired vision and coordination, to headaches, dizziness, nausea, and death.

Home detectors warn occupants of unsafe CO levels and are relatively inexpensive and easy to install. A detector
should be installed wherever there is a fuel-burning device and near the bedrooms. Check consumer testing
results before buying.

129
Resources
Carbon monoxide detectors are available at hardware stores and home supply centers.

HVAC EQUIPMENT

Resources
For information about air exchangers or other ventilation systems:

• “Energy Ideas Clearinghouse.” EIC will provide customized responses to specific questions about
ventilation, 800-872-3568 or e-mail EnergyLine@energy.wsu.edu. Or you can browse for resources
yourself online at www.energyideas.org (listed under General Resources, above).
• Healthy House Building: A Design and Construction Guide (listed in Resources, Technical Books and Guides,
above).
• Understanding Ventilation: How to Design, Select, and Install Residential Ventilation Systems, by John
Bower. Available from the Journal of Light Construction Bookstore, 800-859-3669 or
www.jlconline.com/bookstore.

4-74 Limit kitchen exhaust fan to 300 CFM maximum


1 POINT

With respect to kitchen exhaust range hoods, bigger is not always better. Range hoods should be carefully sized
and installed. If combustion appliances are present or the fan flows are high, provide make-up air to assure safe
operation. In these situations, test to assure that pressure imbalance caused by the exhaust fans do not exceed
minus 3 PA indoors to outdoors, or equivalently, the test meets PCTS performance criteria for controlling
de-pressurization.

100 CFM is the minimum required by ASHRAE Standard 62, and it is generally adequate. The industry
recommendation is for a minimum of 40 CFM per linear foot of cooktop, thus a 48” cooktop would only need a
160 CFM fan. So limit the kitchen fax to 300 CFM as a maximum.

4-75 Install timers, humidistat controls, or occupancy sensors for bath and laundry
exhaust fans
2 POINTS PER DEVICE
4 POINTS MAXIMUM

Homeowners are more likely to use an exhaust fan with a crank or electronic timer switch, avoiding moisture
buildup and eventual mildew problems in bathrooms. Ideally, a fan should run for up to one hour after a hot bath
or shower to ensure complete moisture removal.

A humidistat control will automatically switch the fan on and off to maintain appropriate moisture content in the
space. Look for low-sone fans to encourage use; the quietest fans can hardly be heard when you’re in the same
room.

4-76 Install quiet (<1.5 sone) bath fan with smooth ducting, minimum 4 inch or employ
other quiet ventilation strategy or install ENERGY STAR, or equivalent fan
operating =< 1 sone (3 pts)
1 POINT PER FAN
3 POINT MAXIMUM

130
Spot ventilation removed moisture, odors, and pollutants directly at the source. ASHRAE requires a ventilation
rate of at least 50 cubic feet per minute for the bath fan. Manufacturers offer many options for quiet fans. In fact,
Panasonic offers many fans rated at 0.5 to 1.0 sones. Make sure ducts are smooth (contain no fiberglass or
insulation in the air stream), this provides better air flow. Using minimum 4” ducts are suitable for fans of less than
80 CFM.

Other quiet ventilation strategies include using a ducted central exhaust fan, it offers the quietest operation,
introduces only one roof penetration, and the least wiring. Consider the roof penetration aspect of this strategy if
you plan to go for credit 4—39, Prepare a Roof Water Management Plan. Spot ventilation designs that require
mounting fans on walls and ceilings can be modified to use fans that can be mounted in-line in the duct between
the living space and the exterior, or on the roof or outside wall and connected to the room by a duct. The space
between the in-line or exterior-mounted fan and the interior reduces the noise level in the house. In-line units cost
more for product and installation, but offer the quietest alternative. Additionally both single-point and multi-point
fans offer credit compliant alternatives.

With any spot ventilation exhaust fans, be aware of back-drafting that may introduce elevated concentrations of
pollutants back into the living space. In that case consider using sealed combustion appliances if using natural gas,
and placing these appliances separate from the living space.

4-77 Install exhaust fans in rooms where office equipment is used


1 POINT

More and more residences include home offices or dens where computers, faxes, photocopiers, and other
business machines are used. This office equipment and the supplies associated with it can emit VOCs and gases,
including ozone, which is carcinogenic in high concentrations. A spot fan, installed in a home or commercial
office, is an effective means of reducing health risks by dealing with the pollution at its source. Make sure you
allow for fresh air intake elsewhere in the building to balance the system and ensure adequate ventilation. Look
for “low-sone” fans to avoid distracting occupants; the quietest fans can hardly be heard when you’re in the same
room.

Resources
Spot fans are available from electrical and building material suppliers. Standard bathroom fans will work well,
although you will want to select one that is quiet.

• Broan makes a variety of quiet bath, kitchen, and utility room fans. Look for their Solitaire Ultra Silent
Series and Lo-Sone Ventilators. Broan Mfg. Co., Hartford, WI, 800-548-0790 or www.broan.com.
• American Aldes makes the quiet, efficient CMV (ceiling mounted ventilator) and SV-160 for large
bathrooms. American Aldes Ventilation Corp., Sarasota, FL, 800-255-7749 or www.americanaldes.com.
• Panasonic makes some very quiet fans, Sacaucus, NJ, 201-348-7000, www.panasonic.com.
Also see GreenSpec, listed under Resources, Product Information, above.

4-78 Do not install naturally aspirated heating and hot water equipment
3 POINTS

4-79 No sound insulation or other fibrous materials installed inside ducting


1 POINT

131
Putting sound insulation or other fibrous materials inside the ducting is often done as a measure to reduce the
noise coming from a particular room, such as a music studio or children’s play area. Although this method is very
effectively, it also significantly reduces the air flow, which in turns compromises indoor air quality for these rooms.

To achieve desired sound insulation for these rooms consider additional wall, floor, and ceiling insulation rather
than adding material to the ducts, or a double wall framing, see Action item, 3-26, Innovative Stick Framing to
Reduce Thermal Bridging. Other ideas include: using foam gaskets under plates around receptacles and switches,
caulking between baseboard (or drywall) and floor, use air-tight recessed cans.

4-80 Provide balanced or slightly positive indoor pressure using controlled ventilation
5 POINTS

Greater air tightness creates a need for mechanical ventilation to avoid potential indoor air quality problems.
Balanced ventilation keeps outdoor pollutants from being drawn into the house, prevents backdrafting or spillage
from combustion appliances (due to under-pressurization), and prevents moisture migration into structural
cavities (due to over-pressurization).

It is a good idea to operate the home at a natural pressure (+ 1 Pascal pressure difference with respect to
outdoors). If you accomplish this using supply ventilation only, you may be ignoring other critical factors involved
in making the home energy efficient and healthy. These items need to accompany any attempts to balance a
system.

The primary causes of negative pressure in the home are:

• Wind, natural convection or the stack effect


• Supply duct leaks
• Supply ducts isolated from return ducts by a closed door
• Excessive exhaust ventilation: Usually a large range hood or the clothes dryer.
The best way to bring a home into natural pressure, under normal operating conditions is:

• Caulk and seal the home


• Seal the heating system ducts with mastic
• Provide return air to isolated rooms with ductwork or bypass grille.
Once these items are addressed, the supply ventilation system may be used to balance exhaust ventilation de-
pressurization or provide a slight positive pressure with a modest volume of fresh air. Ventilation can be provided
by quiet fans with automatic controls or by heat recovery ventilators (HRVs) (see Action item 3-50, Install a Heat
Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV)). The volume of air supplied should be provided as
specified in the IRC.

Resources
See resources for Action item 3-50, Install a Heat Recovery Ventilator.

4-81 Install whole house radiant heating system (no ducted heating)
10 POINTS

Hydronic or radiant heating provides Indoor Air Quality benefits in that the ductless system avoids dust,
particulates, chemicals, and germs, and the fans associated with ducted systems. Additionally, these systems
provide comprehensive heating benefits; see Action items, 3-45, Use ductless distribution system (e.g. hydronic,
radiant, ductless minisplits)

132
Hydronic heating uses hot water to distribute heat through baseboard convectors, free-standing radiators, or in-
floor radiant coils. There are four primary components of the system, the boiler, the piping, the heat emitters, and
the controls. See the Energy Action item noted above for more details on the actual system. Boilers can be run of
biofuel.

Resources
• "Radiant Heating" by U.S. Department of Energy's Office, Energy Efficiency and Renewable Energy, a
Consumer’s Guide…. Available online at
http://www.eere.energy.gov/consumer/your_home/space_heating_cooling/index.cfm/mytopic=12590

4-82 If providing central heating and cooling, install whole house humidification
and/or dehumidification
3 POINTS

INDOOR POLLUTANT CONTROL

4-83 Build a lockable storage closet for hazardous cleaning and maintenance
products, separate from occupied space
1 POINT

A lockable storage closet in the garage is one way to (vented to the outside away from fresh air intakes such as
windows) prevent fumes from getting into the living area, as well as toxic or otherwise dangerous chemicals from
getting into the hands of curious children. Keep the storage closet small, to discourage homeowner from
accumulating too many hazardous products, and locate it away from any source of ignition, such as a water
heater. Provide a note in the Homeowner’s Information Kit advising that all hazardous materials should be stored
in original containers.

Program suggests constructing a non-combustible storage unit.

4-84 Install showerhead filter


1 POINT

Studies indicate that exposure to chlorine, absorbed through the skin during showering, can contribute to
increased risk of health problems. Showerhead filters on the market today effectively remove 90% or more of
chlorine from shower water. Some products have pop-in replaceable cartridges that install in seconds and last
nine to twelve months and do not require backflushing.

Talk to your plumbing contractor or local suppliers for product recommendations.

4-85 Do not install gas-burning appliances inside house


1 POINT

Combustion appliances apply to any heating, cooking, clothes dryers, or decorative appliance using natural gas.
Points are awarded in the Indoor Air Quality section to avoid using gas-burning appliances inside the house as a
technique to improve indoor air quality, even though, points are awarded in the Energy Efficiency section for
using these appliances because of the energy benefit.

133
Mostly these appliances are safe to run, thus their support in the Energy Efficiency section, however, under certain
circumstances, these appliances can produce combustion pollutants that can degrade overall indoor air quality,
often leading to damaging the occupants’ health. Therefore, credit is given here to discourage the use of these
potentially harmful off-gassing appliances inside the conditioned space.

Resources
• “What You Should Know About Combustion Appliances and Indoor Air Pollution – What are the health
effects of combustion pollutants?” Environmental Protection Agency, Indoor Air Quality, publications,
http://www.epa.gov/iaq/pubs/combust.html.

4-86 Fireplace, woodstoves, pellet stoves, or masonry heaters are not installed in the
home
7 POINTS

See Above

4-87 Design a designated shoe-removal area and storage at primary entrance


2 POINTS

One of the single most important indoor air quality measures you can take is to minimize bringing pollutants into
the house in the first place. The first line of defense is to remove shoes from the living space that can bring in
pesticides, hydrocarbons, and pollen in from the outside.

Building a shoe removal vestibule at major entrances to the house will help improve indoor air quality and provide
additional Energy Efficiency benefits.

You can build an exterior vestibule, as seen the Figure 4-1, or build one indoors in an underused over-designed
foyer. Make sure the building envelope of the vestibule is tight. In particular, make sure the door is airtight. Good
weatherstripping is essential.

For an exterior vestibule, consider installing a window for natural lighting, you can reuse salvaged single-pane
window because the primary purpose of the vestibule is to create an air loc.

BUILDING ENTRANCE POLLUTANTS CONTROL:


Some studies indicate that up to 80% of indoor pollutants are tracked into the home on shoes. Providing track-off
mats and shoe racks encourages shoe removal, which can go a long way to reducing this source of indoor
pollution.

4-88 Install exterior grilles or mats


1 POINT

4-89 Install interior grilles or mats


1 POINT

4-90 Install floor drain or catch basin with drain under washing machine and/or water
heater

134
1 POINT FOR EACH APPLIANCE
3 POINTS MAXIMUM

This measure helps to avoid additional moisture problems within the dwelling if either the washing machine or
water heater flooded.

4-91 Install moisture alarms under sinks and dishwasher


1 POINT

Moisture alarms are small devices that you can place under sinks and the dishwasher with moisture sensors that
activate with an audible alarm when excess moisture is present. They can be placed on the floor or wall mounted.
They are inexpensive and may contribute to avoiding extensive moisture problems from malfunctioning
equipment, however, they only work if someone is in the house to hear the alarm.

Resources
Ask for plumbing supplier.

ELECTROMAGNETIC FIELDS

4-92 Wire bedrooms so circuitry can be conveniently shut off at night to eliminate
electric fields
2 POINTS

4-93 Design sleeping and sitting areas to be at least 12 feet from major appliances
2 POINTS

4-94 Use no CFLs


1 POINT

Extra Credit for Health and Indoor Air Quality

4-95 Extra credit for innovation in health and indoor air quality
1-10 POINTS

You may submit a health and indoor air quality strategy or system, not specifically called out in this Section, for
consideration for an Extra Credit for Innovation. All extra credits will be approved by the Program Director. If
approved, add up to 10 points to your Section total.

135
Section 5 MATERIALS EFFICIENCY

General Resources
• Look for your local recycling directory
• Resource Conservation Research House Information Guide (also Resource Conservation House Plans and Resource Conservation
House Video), NAHB Research Center, Upper Marlboro, MD. 800-638-8556 or www.nahbrc.org.

Product Information
• GreenSpec – The Environmental Building News Product Directory and Guidelines Specifications, E Build, Inc., Brattleboro, VT,
1999. 802-257-7300 or www.buildinggreen.com. GreenSpec is organized in standard CSI divisions. Environmental Building News
(EBN) also offers product reviews, information, and also lists some articles at the following website:
www.buildinggreen.com/products/productslist.html.
• Guide to Resource-Efficient Building Elements, Center for Resourceful Building Technology, Missoula MT. 406-549-7678 or
crbt@montana.com.
• Green Building Resource Guide, The Architectural Machine, Redwood City, CA. www.greenguide.com. Lists over 600 green
building materials and products, available as CD-ROM database or reference manual.
• Innovative Housing Products Newsletter, NAHB Research Center, Upper Marlboro, MD. 800-638-8556 or www.nahbrc.org.
• Iris Resource Catalog, Iris Communications, Eugene, OR. 800-346-0104 or www.oikos.com/catalog. Publications, videos and
software for green construction
• REDI Guide (Resources for Environmental Design Index). Iris Communications, Eugene, OR. 800-346-0104. Also available free on
the Oikos website: www.oikos.com. A database listing over 1,800 companies and 5,500 products as of 1998. Available in print
or electronic form.

Technical Assistance Programs, Information and Services


• Energy Ideas Clearinghouse, Washington State University Cooperative Extension Energy Program. 800-872-3568,
www.energyideas.org, or e-mail at EnergyLine@energy.wsu.edu. Offers customized responses on green building in addition
to energy efficiency, ventilation, and moisture control.
• NAHB Research Center’s “Tool Base Hotline” is available to answer builder questions, 800-898-2842,
www.nahbcrc.org/ToolBase.
• “Fact Sheet, Jobsite Planning for IAQ, Construction Waste Management, and Site and Water Protection.” O’Brien & Company,
Inc., Bainbridge Island, WA. 206-842-8995 or info@obrienandco.com. ($7.50).

Overall Design

5-1 Design and build for deconstruction concept


5 POINTS: 50% OF BUILDING MATERIALS CHOSEN FOR SIMPLIFYING DECONSTRUCTION
7 POINTS: 75% OF BUILDING MATERIALS CHOSEN FOR SIMPLIFYING DECONSTRUCTION
9 POINTS: 90% OF BUILDING MATERIALS CHOSEN FOR SIMPLIFYING DECONSTRUCTION

Deconstruction is an expanding alternative to traditional building demolition for removing existing structures.
Deconstruction is a coordinated process of disassembling a building and salvaging materials. Deconstruction
increases material life, reduces environmental impact on landfills and harvesting new materials, and saves money
in dumping fees. The Design and Build for Deconstruction concept assimilates design, construction, and
demolition, so as to maximize reusability and durability of building component throughout their functional and
end-of-lifetime.

136
To qualify for this credit, demonstrate or assert that the minimum percentage required for each point range
represents the amount of selectively chosen building components and design elements that contribute to
simplified construction in preparation for future deconstruction.

Materials and system ideas include modular framing, prefabricated structural elements, precast panels for walls,
nail-free paneling, windows that can be replaced without damaging adjacent finishes, mechanical fasteners for
piping connections instead of soldered joints, and centralized accessible wiring and utilities.

If there are dwellings on your building site, see Action item 5-21, Use Deconstruction to Dismantle and Reuse
Existing Building(s) On Site.

Resources
• “Design for Deconstruction”, by Michael Pulaski, Christopher Hewitt, Michael Horman Ph.D. and Bradley
Guy, 2003 (original article created for 2003 Green Build conference).
www.aisc.org/Template.cfm?Section=Technical_Answers&template=/ContentManagement/ContentDispl
ay.cfm&ContentID=26185

5-2 Use stacked floor plan


2 POINTS

Reduce the building size by stacking floor plans. Wet spaces can be located over mechanical areas, minimizing
piping, vents, and chases. By building up versus out, efficiency of land use preserves open space, and tight floor
plans reduce material consumption. Stacked plans also reduce construction costs for site and foundation work.

5-3 Use standard dimensions in design of structure


1 POINT

Incorporating standard sizes in the design will result in less wasted lumber, drywall, and other materials. It also
requires less cutting—saving time and labor. For example:

• Use increments in floor and wall layout to correspond with the standard two- and four-foot increments of
most materials.
• Pay close attention to door and window placement to avoid the need for extra studs or cutting materials
to special sizes.
• Incorporate standard finish dimensions in design. For example, keep standard carpet sizes in mind when
creating floor dimensions.

5-4 Avoid waste from structural over-design


2 POINTS

Reduce
“Reduce” means preventing waste before it happens. The following practices can help you realize significant
reductions in waste and cost of materials on a construction project. Many of the Action items in this section
require only slight modifications to standard procedures.

• Avoid damage. Train site crews to handle and store materials properly.
• Use materials efficiently. Encourage site crews to use scraps and use less materials overall.
• Estimate as accurately as possible. The more accurate, the less waste. Suppliers can often provide tips on
estimating specific materials.

137
• Purchase precut and prefab components.
• Choose strong materials and exploit structural advantages.
• Purchase high-grade materials. These will get more usage and generate less waste in the long run.
• Limit framing waste to 3%. Use efficient framing.

5-5 Create detailed take-off and provide as cut list to framer


2 POINTS

Having a list identifying the intended location of each piece of lumber reduces the overall volume of lumber
needed to construct the house as well as the volume of leftover cut unintentionally. Create a board-by-board
take-off that can be used as a cut list for framers and an order list for your supplier. This list increases
accountability of framers and suppliers and can result in significant savings.

5-6 Use central cutting area or cut packs


2 POINTS

A cut pack is a set of lumber that is pre-measured and pre-cut at the lumberyard to increase efficiency of lumber
use and minimizes on-site waste.

Designating a centralized cutting area reduces wood waste, reduces the total amount of wood that must be
supplied to the site, and saves time by making it convenient for carpenters to reuse cutoffs and scrap. It also
makes the cutting process itself more efficient. Studies of construction sites with a centralized cutting area
showed total waste reduction of as much as 15%.

A central cutting area also creates an ideal location for the wood scraps bin or pile, convenient for subcontractors
to reuse the wood.

5-7 Use suppliers who offer reusable or recyclable packaging


2 POINTS

Cardboard, plastic shrink wrap, Kraft paper, wood pallets or frames, and metal bands are just some of the
packaging materials that can show up on your jobsite. They comprise a significant portion of the typical
construction waste stream, and add to your project cost.

Manufacturers are beginning to take back their own packaging for reuse. Encourage suppliers and manufacturers
to take responsibility for their packaging:

• Request minimal packaging when placing a materials order


• Select products that are delivered with minimal, reusable, or recyclable packaging
• Purchase materials like fasteners, paints, caulking, and drywall mud in bulk containers
Some packaging will always be necessary to prevent materials damage, but the trick is to find the balance
between necessary and excessive packaging. Let your suppliers know you recycle for economic and
environmental reasons.

Items that can be reused cost-effectively include:

• Pallets
• Some corrugated cardboard packaging
• Plastic buckets

138
Reuse
“Reuse” (or salvage) means reusing materials removed during demolition or scraps generated during construction.
Salvage or reuse prevents building materials from becoming waste, and transforms them from a builder liability
and expense, to an asset. In addition, salvage often preserves unique materials not currently manufactured.

You can also encourage others to reuse by donating materials. Reusable items may be sold through classified ads
or a yard/garage sale. Items can also be given away curbside or donated to a charitable organization, which may
be tax deductible. Both for-profit and non-profit reuse centers are emerging which specifically handle used
building materials and sell to either the general public or the low-income community. By donating reusable items,
you add to the cost-effectiveness of your projects through reduced disposal fees and tax advantages, while also
contributing to your community.

Use Salvaged Materials


Reusing materials can reduce project cost by avoiding disposal fees and reducing the need to purchase new
materials. To make reuse easier in temporary structures, apply methods such as fastening with screws rather than
nails to make dismantling convenient. If you have the storage space available, you may be able to store used
materials for future projects.

When reusing structural materials, check with your local building authority regarding strength reductions or
limits. They may be able to assist in determining the strength of various materials, such as reclaimed I-beams.
Code may require some downgrading of structural capacity. In other cases, such as old timbers, structural capacity
may actually be increased.

Note: Make sure when re-using any construction material that the material has been through the proper asbestos
abatement process. For example mastic has been properly removed from flooring following local and federal
asbestos regulations.

5-8 Purchase used building materials for your job


2 POINTS

5-9 Use salvaged doors


1 POINT PER DOOR
4 POINTS MAXIMUM

This credit is available if salvaged doors are purchased from salvage and reuse operations, re-used from other
jobsites, or reclaimed in demolition. See Resources Section.

Consider this credit for interior doors so as to not compromise the integrity of the building envelope.

5-10 Use salvaged flooring


1 POI NT FOR LESS THAN 250 SQUARE FEET
2 POINTS FOR MORE THAN 250 SQUARE FEET

Re-use flooring purchased from salvage and reuse operations, re-used from other jobsites, or reclaimed in
demolition. Salvaged wood flooring can add an attractive feature to a home for example, that could add a rich
historical appeal. Many salvaged woods come from original old-growth timbers, have fewer knots, longer lengths
or widths, and come from species no longer available. Quality and availability can vary widely, but reusing wood
flooring causes no new trees to be harvested.

5-11 Use salvaged windows

139
1 POINT PER WINDOW
2 POINTS MAXIMUM

This credit is available if salvaged windows are purchased from salvage and reuse operations, re-used from other
jobsites, or reclaimed in demolition. See Resources Section. This provides opportunity to retain or reproduce
architectural heritage.

Consider this credit also for reused windows that are placed on the interior where they will not compromise the
integrity of the building envelope.

5-12 Use salvaged appliances


1 POINT PER APPLIANCE
2 POINTS MAXIMUM

This credit is available if salvaged appliances are purchased from salvage and reuse operations, re-used from other
jobsites, or reclaimed in demolition. Ranges, furnaces, dishwashers, refrigerators and hot water tanks are
examples of appliances that can be reused in suitable projects. Reusing appliances saves resources and reduces
the environmental impact of the production of virgin materials.

5-13 Use salvaged fixtures


1 POINT PER FIXTURE
2 POINTS MAXIMUM

This credit is available if salvaged fixtures are purchased from salvage and reuse operations, re-used from other
jobsites, or reclaimed in demolition. Many fixtures can provide an architectural element that can be incorporated
into new designs.

5-14 Use salvaged hardware


1 POINT PER SET OF HARDWARE
2 POINTS MAXIMUM

This credit is available if salvaged hardware is purchased from salvage and reuse operations, re-used from other
jobsites, or reclaimed in demolition. Many salvaged hardware items provide a period-authentic look that could be
incorporated into new homes. Consider handles, drawer pulls, cabinet hardware, drapery hardware, registers,
hooks and brackets.

5-15 Use salvaged cabinets


2 POINTS

This credit is available if salvaged cabinets are purchased from salvage and reuse operations, re-used from other
jobsites, or reclaimed in demolition. Salvaged kitchen cabinets can be restored and reused in the home or for
storage cabinetry in garage or workshop. Period-specific cabinetry can also be restored to add a distinctive look
for bathrooms. These materials/components are available from building salvage and architectural salvage
operations. See Resources Section.

5-16 Use salvaged siding


2 POINTS

This credit is available if salvaged siding is purchased from salvage and reuse operations, re-used from other
jobsites, or reclaimed in demolition. Reuse siding in good condition. Be aware of building envelope considerations

140
when selecting any siding product/material. See Action item 4-51, Install a drainable house wrap under exterior
siding to promote wall drainage.

5-17 Use salvaged decking


2 POINTS

This credit is available if salvaged decking is purchased from salvage and reuse operations, re-used from other
jobsites, or reclaimed in demolition. Decking can be reused as part of new construction.

5-18 Use salvaged trim


2 POINTS

This credit is available if salvaged trim is purchased from salvage and reuse operations, re-used from other
jobsites, or reclaimed in demolition. Trim and moldings can be easily savaged and reused.

5-19 Use salvaged framing lumber


2 POINTS

This credit is available if salvaged framing lumber is purchased from salvage and reuse operations, re-used from
other jobsites, or reclaimed in demolition. According to EPA statistics, a 2000 square foot home generates 127
tons of demolition debris. Ten percent of this is recoverable framing lumber, which averages 6,000 board feet or
33 mature trees.

5-20 Reuse spent solvent for cleaning


1 POINT

Spent petroleum-based solvents must be managed as hazardous waste. If you must use a solvent, consider one
that’s citrus-based. Regardless which solvent type you use, allow solids to settle out of spent solvents in a closed
container. After settling, pour off the clear top layer and reuse. Solids can also be strained from spent solvent
using many different types of paper or cloth filters. Although this technique significantly reduces the volume of
material, settled and strained solids often need to be managed as hazardous waste.

Recycling
To “Recycle” means to separate recyclable materials from non-recyclable materials and supply them to a hauler or
business so they can be processed and used to make new products. By choosing to recycle on your jobsite you
will:

• Reduce disposal fees and overall construction costs.


• Provide “stock” for new materials to be manufactured.
• Keep valuable material from entering landfills.
Two recycling options are available: Source Separation Recycling or Commingle Recycling.

Source separation recycling is the process of sorting materials into separate on-site containers based on recycling
categories. These containers are taken to specific facilities for recycling.

Commingle recycling is the process of collecting all recyclable materials in one on-site container. The container
must have a minimum of 90% recyclable materials. This container is taken to a facility where materials are sorted
for recycling.

141
In some cases, jobsite logistics may determine your recycling option selection. In confined jobsites, commingle
recycling offers the benefit of a single container. In other cases, your crew may determine your choice. If a crew is
committed to the environment and you can depend on them to manage the on-site recycling and complete
separation of materials, you may choose source separated recycling

Evaluate your waste stream, and target materials that have significant market value, that have local cost-effective
recycling options, and can be conveniently source-separated. Typically this includes wood, cardboard, metal,
drywall, concrete, and masonry. To assist in source separation, identify locations on site to collect these materials
and use signs to clearly identify materials being collected in that location. (You may want to limit the number of
bins by setting them up on a phased basis to correspond to the phases of construction and the typical waste
streams generated during each phase.)

You can transport your recyclable materials to these facilities in a variety of ways. Consider the following
methods:

• Full-service recycling contractors. They provide all bins, on-site sorting, and pick-up.
• Garbage hauler. Your hauler may provide bins and pick-up for certain materials.
• In-house recycling. Working with individual recyclers, you arrange bins, pick-up, and/or self-haul.
• Subcontractors recycling. Subs work with individual recyclers to arrange bins, pick-up, and/or self-haul.
Some companies, such as scrap metal dealers, will pay for recyclable material. Others charge to accept or pick up
recyclables. Even if a fee is charged, however, it is generally less than fees paid for disposal. Recyclers have
specifications for the quality, types, and grades of materials they can accept. To achieve the most benefit from
your efforts, find out what these specifications are.

Resources
• Residential Construction Waste: A Builder’s Field Guide, NAHB Research Center, Upper Marlboro, MD.
800-638-8556 or www.nahbrc.org.
• www.oikos.com/library/waste/index – Useful information about types and quantities of construction waste
and disposal costs in the construction industry. Also available are helpful publications and brochures for
builders developing jobsite waste management plans.

Source-Separated Recycling

5-21 Use deconstruction to dismantle and reuse existing building(s) on site


5 POINTS

ARCHITECTURAL ELEMENTS/FIXTURES: 2 POINTS

ARCHITECTURAL ELEMENTS/FIXTURES PLUS LARGE PIECES: 10 POINTS

EVERYTHING SALVAGEABLE FROM BUILDING WAS AT LEAST

20% OF TOTAL DECONSTRUCTION WASTE: 20 POINTS

This credit is designed to salvage reusable materials from existing buildings onsite through deconstruction. This
credit is distinguished from others in this category through requirements of reusing materials specifically salvaged
from the project site, not from other locations.

Architectural Elements/Fixtures include antique original lighting and hardware, mantels, timbers, tongue and
groove paneling, flooring, window trim, faucets, shelving, bricks, and pavers.

142
Architectural elements/fixtures plus large pieces include cabinets, windows, (consider energy efficiency tradeoffs
for windows and appliances) crown molding, sinks, bathtubs, built-in china hutches, wrought-iron railings.

Everything Salvageable includes all the above listed items plus reusing scrap wood to build shelves, shoe removal
vestibule, roof shingles, bricks, slate, broken concrete.

Note: prior to beginning any renovation or demolition work, an asbestos survey must be performed by an
accredited AHERA Building Inspector. In addition, a completed Notice of Intent must be submitted before any
asbestos removal, and all asbestos-containing materials must be removed by asbestos workers prior to
demolition. See your local jurisdictions to help you understand the asbestos rules.

The 85% rate is set because if more than 10% of the container is contaminated with non-recyclable materials, the
recyclables materials will not be accepted.

5-22 Recycle cardboard by source separation, 85% minimum recycling rate


1 POINT

Cardboard is generated throughout most homebuilding and remodeling projects, but the largest volume occurs
during the finish phase of the project when electrical and mechanical fixtures are being installed. Cardboard can
often be recycled for free, either at drop-off sites or picked up by a hauler who may provide a bin. Wax, moisture,
and metal banding can be considered contaminants. Check with cardboard recycler to identify any restrictions on
the cardboard they accept.

5-23 Recycle metal scraps by source separation, 85% minimum recycling rate
3 POINTS

Copper scraps have been recycled for years because the metal has a high market value. As other metals (steel,
iron, aluminum) have increased in value, it has become more beneficial to recycle them as well. Metal can be
collected or accepted for free, with higher value metals providing revenues. Rebates available for recycled metals
vary with market value. Separated metals have a higher value than mixed metals. Some recyclers will pay for
sorted metals. Check with recycler for specifications.

5-24 Recycle clean scrap wood and broken pallets by source separation, 85% minimum
recycling rate
5 POINTS

On average, about 25% of discarded construction materials is dimensional lumber and another10% is waste from
manufactured wood products. Wood scrap you can’t reuse should be targeted for recycling. Clean wood scraps
refer to unpainted and untreated materials. Wood processing technology has improved significantly, and more
and more of the construction wood waster stream can be recycled. Check with wood recycler to identify any
restrictions on the wood they accept. Depending on the final use of the material, the following may be considered
unacceptable contaminants: paint, stain, pressure treatment, lamination, adhesives, and nails or other fasteners.
Many of the region’s wood recyclers also accept pallets as part of their wood waste stream. Consult the directories
of services or contact your wood recycler first.

5-25 Recycle package wrap and pallet wrap by source separation, 85% minimum
recycling rate
2 POINTS

143
Material packaging makes up a substantial percentage of construction material waste. Keeping material out of
the waste stream helps preserve landfill space. Recycle packaging or have subcontractors make arrangements to
take the packaging back to the supplier.

5-26 Recycle drywall by source separation, 85% minimum recycling rate


3 POINTS

Drywall generally makes up 11% by volume and 26% by weight of a residential home’s waste stream or roughly1-
1.2 lbs. per square foot. Drywall is most often recycled as feedstock for more drywall. If your drywall
subcontractor handles his or her own waste, work with the subcontractor to develop a recycling program.

Resources
th th
• New West Gypsum, 1321 – 54 Ave. East, Fife (253-922-9343) or 3525 – 136 St., NE, Marysville (360-653-
3494). Accepts gypsum drywall scraps and drywall related waste (mud boxes, tape, cornerboard). NO
drywall with lead-based paints or asbestos laden material. Rents containers.

5-27 Recycle concrete/asphalt rubble, masonry materials, or porcelain by source


separation, 85% minimum recycling rate
2 POINTS

Concrete, brick, and asphalt rubble can be collected on site and recycled for less money than it costs to be
landfilled. On large demolition projects, where a significant amount of asphalt or concrete is being demolished as
part of site preparation, the material can be ground to meet base or fill specifications and reused on site.

5-28 Recycle paint by source separation, 85% minimum recycling rate


1 POINT

Paints may be taken to the household hazardous waste areas. Check with your solid waste collector to see if full
cans of paint are acceptable.

5-29 Recycle asphalt roofing by source separation, 85% minimum recycling rate
4 POINTS

Asphalt roofing is collected and recycled at several companies in the Eastern Washington area. See resource
section for list of service providers.

5-30 Recycle carpet padding and upholstery foam by source separation, 85%
minimum recycling rate
2 POINTS

Recycled Carpet pad is remanufactured back into new feedstock.

5-31 Recycle glass by source separation, 85% minimum recycling rate


1 POINT

144
Fluorescent bulbs and ballasts are recyclable and not allowed in landfills. See Resources for recycling options.
Also, provide source separation glass recycling container to collect beverage containers and other non-reusable
glass materials.

5-32 Recycle land clearing and yard waste, soil, and sod by source separation, 85%
minimum recycling rate
3 POINTS

Many companies throughout Eastern Washington collect and process land clearing debris and yard waste. In
addition, there are companies that offer mobile grinding services in which they will process land clearing debris at
the jobsite. This reduces transportation cost and provides a material to use on your site for site protection
activities.

5-33 Recycle fluorescent lights and ballasts


4 POINTS

5-34 Donate, give away, or sell reusable finish items


1 POINT

Rising raw materials costs and landfill tipping fees are making it more economical for builders to salvage materials
for reuse than to pay for new materials and/or disposal costs. Donating materials to a registered 501c3 not only
avoids the cost of disposal, but also provides a tax deduction.

Prior to the start of a demolition or a renovation project, the builder, designer, and owner should schedule a
walk-through to identify materials that might be salvaged. If you intend to sell salvaged materials, a
representative from the salvage business should be included in the initial walk-through to help identify
salvageable materials that are in demand.

Products with consistent demand include:

• Hardwood flooring
• Windows that are in good condition (matching sets preferable)
• Kitchen cabinets and solid wood doors
• Architectural detailing, window and door hardware
King County, in cooperation with the City of Seattle, offers a construction recycling directory. The directory
includes a section on “Reusable Building Materials, Salvage Services and Materials Exchanges.” Companies and
organizations that accept reusable building materials are listed. Snohomish County’s directory also has a similar
section. See the Part II, Section Five Resources, for details. You can also consult your local telephone book

Resources
See Action item 5-34, Donate, Give Away or Sell Reusable Finish Items, for a list of vendors who sell or accept used
building materials.

5-35 Move leftover materials to next job or provide to owner


1 POINT

145
Many materials can be moved to the next job or left on site for the new owner at their request to use for repairs or
expansions. Paint, for example, can be left with owners for touch-ups and repainting, or can be used as a primer
on your next job. Decking material can be reused by the owner as part of a future expansion or for other
landscaping applications. Also look for opportunities to donate materials to a reusable building materials facility.

Commingle Recycling
Many jobsites are not ideal for source separation recycling or the project team is focused on a simplified system.
The ease of commingle (or mixed material) recycling maximizes the potential of overall diversion with the least
amount of effort. There are several companies that offer services for commingle recycling. They can provide
containers and haul recycling to appropriate facilities. See Section Five Resources.

The first three Action items in the category require that the project recycling rates meet a minimum of 85%. The
distinction between the three items is based on the recovery rate of the recycling facility with whom you contract.
More points are awarded for contracting with commingle recycling facilities that are diverting more material from
the mixed material feedstock. See Section Five Resources for web sites that list the Facility Recycling Rates. For
each of these Action items, the facility recycling rate is the “Appropriate for Processing Recycling Rate” list in
column two of the table in the weblink.

5-36 Send at least 90% of jobsite waste (by weight, excluding concrete, brick and
asphalt) to a commingle recycling facility with a recycling rate of 50 %
5-37 Send at least 90% of jobsite waste (by weight, excluding concrete, brick and
asphalt) to a commingle recycling facility with a recycling rate of 75 %
5-38 Send at least 90% of jobsite waste (by weight, excluding concrete, brick and
asphalt) to a commingle recycling facility with a recycling rate of 90%
10 POINTS FOR 50% FACILITY RECYCLING RATE
18 FOR 75% FACILITY RECYCLING RATE
24 POINTS FOR 90% FACILITY RECYCLING RATE

To receive credit for this Action item, the project must divert at least 50% of the jobsite waste (by weight,
excluding concrete) to a Commingle Recycling Facility with an “appropriate for processing recycling rate of 50-, 75,
or 90%. See the Resources section for an on-line weblink and a phone number to get information on which
commingled recycling facilities meet these criteria.

DESIGN AND MATERIAL SELECTION


This category includes Action items intended to help you make design and material selection choices, which
benefit the environment while still providing the quality and performance you demand for your projects. In
addition to promoting the purchase of materials that include recycled or “reworked” content, these Action items
also suggest methods to reduce the use of limited resources.

Many standard construction materials that you are accustomed to using contain recycled-content and have for
years. Furthermore, technology advancements have allowed the introduction of many new building products
made with recycled-content that are also cost-effective and perform well.

By buying building products with recycled-content you reduce the use of “virgin” materials to produce
construction products. Also, by specifying engineered products and waste-limiting framing options, you conserve
materials which otherwise would have contributed to your site waste. All of these efforts conserve limited landfill
capacity. In addition, you help encourage the market for recycled and engineered products. The end benefit will
be competitive pricing for the finished products as well as better value for the recycled material used to make
those products, including materials you recycle from your jobsite.

Recycled-content products can include two kinds of recycled material—post-industrial and post-consumer.
Post-industrial recycled-content means the product includes waste material created as a by-product of an
industrial process, such as sawdust produced in the milling process, or plastic “grinds” produced during the
146
manufacture of a plastic product. Post-consumer recycled-content means the product includes waste material
created as a result of actual use by the consumer (such as carpet or wood waste). The higher the post-consumer
content in a product the better. However, any recycled-content is better than none at all, when compared to using
products with virgin materials that can require a lot of energy or other resources to produce.

When ordering building products from suppliers, it’s important to let them know your preference for
recycled-content alternatives. Manufacturers producing recycled-content building products typically produce an
equivalent without recycled-content (often with no price differential), and if you don’t specify recycled-content,
you may not get it.

Another way to be a BUILT GREEN builder is to use products manufactured in the area, thus reducing the amount of
energy used to get them to your site. The energy used to transport finished building products to their distribution
site or directly to your site is one form of “embodied energy.” Embodied energy is energy “contained” in materials
that has been used in resource extraction, manufacture, transport, installation, and, after useful life is over,
removal and disposal. Besides reducing energy use, using locally manufactured products reduces air pollution
associated with that energy use and supports the local business community.

Finally, in this section, information is provided about resource-efficient products available as of this writing. Many
products are readily available and are, for the most part, cost-competitive – see the Resources Section for specific
product information.

Many Action items in this Section require choosing wood products that come from sustainably harvested forests.
There are over 50 voluntary forestry standards programs worldwide at the time of this writing. Many of the
programs are still evolving and others are emerging. Credit in the BUILT GREEN program will require that the wood
products selected for the project can be independently certified to be coming from forests that meet one of the
following two criteria:

Table 5-1 Wood Certification Guidelines

Certified Wood Products Tier 1 Requirements:

• Independently third-party audited chain of custody. Chain of custody refers to a certification that
guarantees a wood product has been tracked from a certified forest to the final product to ensure it came
from a sustainable forestry source. Tracking also guarantees that products will not be mixed with non-
certified products during processing, manufacturing and distribution.

• No conversion of natural forest to plantation

• No mass harvest of old growth trees

• No GMO/Pesticides (GMO – genetically-modified organisms)

• Multi-stakeholder governance with transparent decision-making process

• Rules for control of non-certified components in certified products

• Supported by leading environmental and social organizations

• Policy of removal for non-compliance.

Certified Wood Products Tier 2 Requirements:

• Independently third-party audited chain of custody

• No conversion of natural forest to plantation

• No mass harvest of old growth trees

• Rules for control of non-certified components in certified products

147
• Policy of removal for non-compliance.

Resources
• “Material Selection: Tools, Resources, and Techniques for Choosing Green.” Environmental Building News,
January 1997, Volume 6, Number 1, Brattleboro, VT. 802-257-7300 or
www.buildinggreen.com/products/productslist.html.
• “Designing for Disassembly,” Solplan Review, July 1999. North Vancouver, BC. 604-689-1841 or e-mail at
solplan@direct.ca.
Also see the General Recourses at the beginning of this section and refer to prerequisites, Conform to the House
Size Matrix.

For wood certification guidelines, see Part 1, Section Five, Design and Material Selection, Table 5.1 for the list of
requirements.

Overall

5-39 Install locally-produced materials


1 POINT PER ITEM
10 POINTS MAXIMM

Supporting the use of indigenous resources reduces the environmental impacts resulting from transportation.
“Locally produced” materials are generally considered to be produced, both manufactured and extracted, within a
500-mile radius.

See your local supplier and ask for information on the origin of the materials.

5-40 Use building salvaged lumber, minimum 200 board feet


1 POINT FOR EVERY 200 BOARD FEET
8 POINTS MAXIMUM

This credit does not apply to new wood from trees cut on site, but does apply to salvaged lumber from an existing
on-site, deconstructed building or commercially salvaged and reused building material sources. See Action item 5-
21, Use Deconstruction to Dismantle and Reuse Existing Building(s) On Site, for further information. Points for this
credit are awarded for the quantity of salvaged lumber from deconstructed sources.

The most common commercially salvaged and reused building component is wood salvaged from beams in
turn-of-the-century buildings or abandoned railroad trestles. Consequently, reclaimed wood is often available in
species, coloration and wood quality not found in today’s new material markets. Some companies offer original
hand-hewn beams for reuse in their present form. Others provide salvaged wood re-milled into flooring, millwork,
or paneling. Most companies grade the wood depending on its grain, the number and type of knots, and the
number of nail holes left from its prior use.

5-41 Use urban or forest salvaged lumber, minimum 250 board feet
2 POINTS: ANY LUMBER SALVAGED FROM URBAN OR FOREST RESOURCES
3 POINTS: ANY LUMBER SALVAGED FROM BUILDING SITE*

THIS CREDIT APPLIES TO NEW WOOD RECOVERED FROM URBAN OR FOREST SALVAGE OPERATORS.

Many wood suppliers offer new wood products that are made from wood salvaged from urban or forest resources.

148
Urban salvage refers to trees removed from urban parks, campgrounds, and recreation areas, possibly damaged
from disease or considered a hazard. Other sources include trees removed from construction sites for clearing and
grading.

Forest salvage refers to trees recovered from forest restoration projects or removed from forestland to make way
for roads, campgrounds, or utility lines. It may also refer to hazardous trees removed from campgrounds. Instead
of being chipped or used as firewood, these trees are sent to a mill and processed into flooring, trim, and other
finish materials.

This credit does not apply to burning salvaged materials.

* Over cutting on the site to achieve the points for this credit is not the intention of the credit. Only salvage trees
that were originally planned for removal. (See Section Two: Site and Water, Protect Site’s Natural Features Action
items.)

Resources
• Healthy Forests Healthy Communities (HFHC). 620 SW Main, Suite 112, Portland. 503-221-6911 ext. 112.
http://www.hfhcp.org/products.php. Resource for urban and forest salvaged materials.

5-42 Use rapidly renewable building materials and products made from plants
harvested within a ten-year cycle or shorter in at least 2 substantial applications
3 POINTS

This credit does not apply to finish flooring or OSB. To achieve flooring credit, see Action items 5-65, On more than
250 square feet, use rapidly renewable flooring products with a ten-year harvest cycle or shorter (excluding carpet).

Acceptable materials include cork, bamboo, agricultural panel board, strawboard, and plant-based finishes.
Acceptable applications could include: cork as a wall finish, bamboo for countertops, paneling, or wall finish,
agricultural panel boards as cabinets, countertops, wall and ceiling finish, and plant based finish on any wood
surface.

Cork and bamboo are both renewable resources and natural materials. Cork is sustainable because the bark is
harvested and the tree is left to regenerate more bark. The bark is harvested on an eight-year cycle. Cork flooring
is durable, sound absorbing, and naturally moisture-, mold-, and rot-resistant. Bamboo is sustainable because it
can be harvested on a six to eight year cycle. Bamboo flooring is a very durable and dimensionally stable material.
Despite the long-distance transport of the products to the United States, the durability, hardness, and short
regeneration time of bamboo provide justification for specifying bamboo flooring instead of wood. There are also
indoor air quality advantages to using natural materials - they off-gas less due to fewer or no chemicals used in the
manufacturing process.

Paneling made from reclaimed agricultural fibers is plant-based and sustainable because it is harvested on an
annual or semi-annual cycle. The straw that makes up strawboard for example can be harvested every 2-3 years.
Strawboard can be a substitute for wood particleboard and medium-density fiberboard. Seek out products that
have no added formaldehyde in the bonding agents and finishes.

Plant-based finishes refer to products made from rapidly renewable vegetable oils, citrus oils, waxes and mineral
oils. They often create a more natural looking final product.

5-43 Use environmentally preferable products with third-party certification, such as


SCS, GreenGuard, and Floor Score (not applicable to carpet)
2 POINTS

149
Third-party certification is based on standards developed by an unaffiliated organization. Third-party certification
standards establish criteria and verify manufacturer claims regarding the environmental, social and economic
benefits of their products.

To receive credit for this Action item, use any certified products from any the following organizations, other than
carpet (carpets are not applicable under this credit).

Science Certification Systems (SCS) is a third-party certifier that promotes


sustainable development in the forms of environmental protection and social
responsibility.

Greenguard Environmental Institute governs the Certification Program,


another third-party certification organization that provides information
related to Indoor Air Quality on insulation, air filters, doors, floor finish,
flooring, and wall finish.

Green Seal is a third-party certification organization that evaluates, tests and


visits manufacturing facilities to identify a product as environmentally
preferable.

The FloorScore program, developed by the Resilient Floor Covering Institute


(RFCI) in conjunction with Scientific Certification Systems (SCS), tests and
certifies flooring products for compliance with indoor air quality emission
requirements. Flooring products include linoleum, laminate flooring, wood
flooring, ceramic flooring, rubber flooring, wall base, vinyl, and associated
sundries.

Resources
• “Forest Certification Test Project”, USDA Forest Service.
www.fs.fed.us/news/2005/releases/08/factsheets.pdf. Discusses four major forest certification programs.
• Forest Stewardship Council. www.fsc-info.org. Manufacturer and product search engine for chain of
custody certificate holders.
• Green Seal. 1001 Connecticut Avenue, NW Suite 827, Washington, DC. 202-872-6400. www.greenseal.org/.
Discusses standards of Green Seal product certification.
• Scientific Certification Systems. 510-452-8007. www.scscertified.com/forestry/forest_indie.html.
Discusses SCS forest certification standards.
• Greenguard Environmental Institute. 1341 Capital Circle, Suite A, Atlanta. 800-427-9681
www.greenguard.org/. Discusses Greenguard’s mission and certification programs.

5-44 Use recycled-content plastic lumber


2 POINTS

Framing

5-45 Use dimensional lumber that is third-party certified sustainably harvested wood
that meets the Tier 1 requirements outlined in the handbook, 50% minimum
7 POINTS

150
To receive credit for this Action item, the dimensional lumber selected for the project must meet Certified Wood
Products Tier 1 Requirements listed under Design and Material Selection, Wood Certification Guideline for Section
Five. (See Table 5.1, at the beginning of the Design and Material Selection section.)

Currently, only the Forest Stewardship Council (FSC), a voluntary, market-based, certification organization, meets
Tier 1 requirements. It is one of few programs that require a chain of custody for certification. FSC sets standards
for sustainable forestry practices and depends on independent companies for third-party certification of
forestlands. It evaluates and monitors certifiers to ensure public credibility.

Two private companies in the U.S. are authorized to issue the FSC stamp of approval: Scientific Certification
CM
Systems (SCS) in Oakland, CA, and SMARTWOOD Certified Forestry, based in Richmond, VT (with an affiliate in
Oregon). By purchasing wood from certified forests, you ensure a given product comes from a well-managed
forest and demonstrate support for sustainable forest stewardship practices worldwide. At the conception of the
BUILT GREEN program (2000) 5 million acres of forestland had been certified by FSC. As of January 2006, there is 22
million acres of FSC certified forestland in the U.S. Many more retailers lately are certified in the chain-of-custody
and supply FSC certified products. Also, the variety of materials available in FSC is also expanding.

Resources
Although there are several Certified Wood Distributors nationally listed in GreenSpec (see Resources, Product
Information), several are located in the Pacific Northwest:

• Collins Wood, Portland OR. 800-329-1219. Offers plywood, particle board, and dimensional lumber.
• Edensaw Woods, 211 Seton Rd., Port Townsend, WA. 800-745-3336 or 360-385-7878. Website:
www.edensaw.com. Offers selections of certified wood including ash, beech, birch, cherry, Honduras
mahogany, fir, maple, poplar, red oak, and white oak. Some certified veneers available.
th
• Endura Hardwoods, 1303 SE 6 Ave., Portland, OR. 503-233-7090 or www.endurawood.com. Offers
certified hardwood and softwood lumber and a range of wood products (including flooring and butcher
block counter tops) in the following species: red alder, ash, birch, cherry, Douglas fir, maple, red oak, white
oak, redwood, and mahogany. Also antique and vintage (rediscovered) woods.
• Environmental Home Center, 4121 1st Ave. S., Seattle. 206-682-7332, 800-281-9785, or
www.environmentalhomecenter.com. Offers framing lumber, flooring, custom order for trim, panel
goods, shingles, and raw lumber.
• Dunn Lumber, multiple locations offer FSC-certified products, 206-632-2129, www.dunnlum.com
st
• Compton Lumber & Hardware, 3847 – 1 Avenue, Seattle, 206-623-5010, http://www.comptonlbr.com/
• Forest Stewardship Council. www.fscus.org/news/archive.php?article=433&. Provides statistics about FSC
certified land.
• Forest Stewardship Council. www.fsccanada.org/chainofcustody2.htm. Explains “chain of custody” related
to forest certification standards.
o Forest Stewardship Council. www.fsc-info.org. Manufacturer and product search engine for
chain of custody certificate holders.
For general information on certified lumber, contact:

• Certified Forest Service Council, Jeff Wartelle, 503-590-6600. Industry group provides information on
distribution and other assistance.

5-46 Use dimensional lumber that is third-party certified sustainably harvested wood
that meets the Tier 2 requirements outlined in the handbook
1 POINT

151
For credit for this Action item, use dimensional lumber that meets Certified Wood Products Tier 2 Requirements
listed under Design and Material Selection, Wood Certification Guidelines for Section Five. (See Table 5.1, at the
beginning of the Design and Material Selection section.)

Currently, there are no programs that meet these criteria, however, a few are expected to on-line soon.

Resources
As of February 2007, no certification program meets the Tier 2 requirements. Contact the BUILT GREEN program
for updates.

A few programs may meet this criteria soon, information for these programs is included for future reference:

• Sustainable Forestry Initiative. 1655 North Fort Myer Drive, Suite 1300, Arlington, VA.
www.aboutsfi.org/sfilabel.asp. Describes SFI’s standards as a comprehensive forestry management
program.
• Canadian Wood Council. 99 Bank Street, Suite 400, Ottawa, Ontario. 800-463-5091. www.cwc.ca/.
Comprehensive listing and description of North America’s forest certification standards and programs.
• The American Tree Farm System. 1111 Nineteenth Street, NW, Suite 780, Washington, D.C. 202-463-2462.
www.treefarmsystem.org/. Describes the American Tree Farm System’s sustainable forest management
standards and guidelines.

5-47 Use sheathing that is third-party certified sustainably harvested wood that meets
the Tier 1 requirements outlined in the handbook, 50% minimum
5 POINTS

To receive credit for this Action item, the sheathing selected for the project must meet Certified Wood Products
Tier 1 Requirements listed under Design and Material Selection, Wood Certification Guideline for Section Five. (See
Table 5.1, at the beginning of the Design and Material Selection section.)

Currently, only the Forest Stewardship Council (FSC), a voluntary, market-based, certification organization, meets
Tier 1 requirements. It is one of few programs that require a chain of custody for certification. FSC sets standards
for sustainable forestry practices and depends on independent companies for third-party certification of
forestlands. It evaluates and monitors certifiers to ensure public credibility.

Resources
See Resources listed for 5-45, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 1 Requirements Outlined in the Handbook, 50% Minimum

5-48 Use sheathing that is third-party certified sustainably harvested wood that meets
the Tier 2 requirements outlined in the handbook
1 POINT

For credit for this Action item, use sheathing that meets Certified Wood Products Tier 2 Requirements listed under
Design and Material Selection, Wood Certification Guidelines for Section Five.

Currently, there are no programs that meet these criteria, however, a few are expected to on-line soon.

Resources
See Resources listed for 5-46, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 2 Requirements Outlined in the Handbook.

152
5-49 Use beams that are third-party certified sustainably harvested wood that meets
the Tier 1 requirements outlined in the handbook, 50% minimum
5 POINTS

To receive credit for this Action item, the beams selected for the project must meet Certified Wood Products Tier 1
Requirements listed under Design and Material Selection, Wood Certification Guideline for Section Five. (See Table
5.1, at the beginning of the Design and Material Selection section.)

Currently, only the Forest Stewardship Council (FSC), a voluntary, market-based, certification organization, meets
Tier 1 requirements. It is one of few programs that require a chain of custody for certification. FSC sets standards
for sustainable forestry practices and depends on independent companies for third-party certification of
forestlands. It evaluates and monitors certifiers to ensure public credibility.

Resources
See Resources listed for 5-45, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 1 Requirements Outlined in the Handbook, 50% Minimum

5-50 Use beams that are third-party certified sustainably harvested wood that meets
the Tier 2 requirements outlined in the handbook
1 POINT

For credit for this Action item, use beams that meets Certified Wood Products Tier 2 Requirements listed under
Design and Material Selection, Wood Certification Guidelines for Section Five.

Currently, there are no programs that meet these criteria, however, a few are expected to on-line soon.

Resources
See Resources listed for 5-46, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 2 Requirements Outlined in the Handbook.

5-51 Use factory framed wall panels (panelized wall construction), including SIPs and
ICFs
2 points

Pre-fabricated wall panels are built in a factory based on individual building plans. Since the panels are
manufactured in a quality-controlled environment, they are stronger, more dimensionally accurate, and more
durable structures. They are built, labeled for assembly and shipped to the job site. Builders follow assembly
procedures defined by factory specifications.

Although points are awarded in Section Three, Energy Efficiency, for using SIPs (see Action items 3-21, Use
structural insulated panels (SIPs), insulated concrete forms (ICFs) or straw bale for exterior walls around conditioned
space.) Additional points are awarded here to recognize the material benefit in addition to the energy efficiency
benefit of using this product.

Using structural insulated panel (SIP) systems for wall, roof, and flooring applications instead of traditional stick
framing can be an effective way to reduce the amount of wood used in a building. Panel systems have been in use
for over 30 years and a variety of systems are available. The most common system includes a foam core
sandwiched between oriented strand board (OSB) skins. Avoid structural insulated panels produced with
ozone-depleting HCFCs. EPS (expanded polystyrene) does not contain HCFCs or other ozone-depleting
chemicals. Non-ozone-depleting polyurethane is now available

153
In order to get optimum performance and waste reduction out of a panel system, first carefully evaluate your
building plans to see if panels are appropriate. A complex shell design with lots of window or door openings can
make it more difficult to use panels resourcefully. If you decide to use panels, make sure your framer understands
how to work with them. Improper installation can negate the benefits. (The manufacturer should be able to
provide some assistance when you start using these products.)

See Energy Efficiency section Action item 3-21, Use structural insulated panels (SIPs), insulated concrete forms
(ICFs) or straw bale for exterior walls around conditioned space for more information on the energy aspect of this
building method. In addition to energy savings, this method also represents an opportunity to use a waste
product, fly ash, in standard building material, which coincidentally offers superior performance. Flyash waste
from coal burning has been shown to improve the strength of concrete (see Action item 5-57, Use Flyash or Blast
Furnace Slag For 25% by Weight of Cementitious Materials for All Concrete (20% for Flat Work).

In addition, some ICF systems are made with waste wood. The system offers significant savings in labor by
combining framing, insulating, and sheathing. Less waste is produced because of the system’s flexibility (the
forms can be cut to any shape). Additionally, many systems have “studs” built in so there’s something to nail or
screw to, and sheetrock may be attached directly to the foam’s interior surface. Exterior siding material, such as
wood, vinyl, brick, or stucco, can be easily attached.

• Tool Base Services.


www.toolbase.org/Techinventory/TechDetails.aspx?ContentDetailID=977&BucketID=6&CategoryID=13.
Provides technical information on structural insulated panels (SIPs).

Resources
See Section Three: Energy Efficiency Action item 3-15, Airtight drywall approach for framed structures using thermal
enclosure checklist. For information on using flyash in concrete see Action item 5-57, Use flyash or blast furnace
slag for 25% by weight of cementitious materials for all concrete (20% for flat work).

5-52 Use truss roof system


3 POINTS

5-53 Use engineered structural products and use no dimensional 2xs larger than 2x8,
and no 4xs larger than 4x8
3 POINTS

There are many engineered structural products, including laminated veneer lumber (LVL), wood I-beams and
I-joists, and wood roof and floor trusses. These products combine efficient raw material use with improved
strength and performance capabilities to produce a superior option to traditional materials. Engineered lumber
manufacturers use fast-growing, small-diameter trees efficiently.

Combining wood veneer and fiber with adhesives produces LVL. The LVL manufacturing process allows more of
the log (up to 80%) to end up as product. LVL lumber is very consistent and stable. Wood I-beams and I-joists also
combine veneer and adhesives.

LVL headers and I-beams are accepted by all major building codes. They provide more load-bearing capacity than
solid sawn lumber, and resist shrinking, twisting, splitting, warping, and crowning. They are capable of long spans,
thereby increasing design flexibility. They can cost more than dimensional lumber, but in general are considered
better products. The American Plywood Association estimated that in 1998 I-joists alone accounted for over a
third of all residential floor joists installed in the U.S.

154
Wood, roof, and floor trusses are commonly used instead of cut rafters because they save both time and
materials. They can also reduce wood waste because, ideally, you order only what you need, and because of
efficiencies in the production process.

Prevent waste by making sure you and your truss supplier are “on the same page.” Supply a detailed building plan
(calling out any unusual requirements due to an oddly shaped cathedral ceiling or an opening planned through the
roof framing). Also, make sure trusses are stored flat to prevent warping.

Be aware of the indoor air quality issues associated with formaldehyde binders. Look for products that do not
contain this type of binder or, at a minimum, use phenol formaldehyde in place of urea formaldehyde binders. Ask
your supplier for more information. Also ask them about manufacturers who use certified wood in their
engineered wood products.

Resources
• GreenSpec, see Resources, Product Information.
• Trus Joist MacMillan, Beaverton, OR. 800-391-2611. Distributes a variety of engineered structural products
(including Parallam PSL and TimberStrand LSL) to local lumberyards. See your local supplier for other
engineered structural materials as well.
• Willamette Industries in Oregon, 800-887-0748. Distributes engineered structural products (including
StrucJoist, StrucLam LVL, and E--Z Frame System). For product information, contact the local distributor,
CMI Northwest in Woodinville at 425-475-2320.
For more information see:

• Building with Alternatives to Lumber and Plywood, NAHB Research Center, Upper Marlboro, MD.
800-638-8556 or www.nahbrc.org.
• “Engineered Lumber Update,” Journal of Light Construction, March 1998. Williston, VT. 802-859-3669 or
www.jlconline.com/bookstore. (Last page lists related articles as well as a number of manufacturers of
engineered lumber.)
• “Setting Trusses: Tips from the Tracts,” Journal of Light Construction, April 1995. Williston, VT. 802-
859-3669 or www.jlconline.com/bookstore.
• Truss-Framed Construction, NAHB Research Center, Upper Marlboro, MD. 800-638-8556 or
www.nahbrc.org.
• “What’s The Difference? Structural Composite Lumber: LVL, PSL or LSL?”
Fine Homebuilding, April/May 1998. Taunton Press, Newtown, CT. 800-888-8286

5-54 Use finger-jointed framing material (e.g. risers and studs) longitudinal
compression loads only
3 POINTS

Finger-jointing or engineered studs (gluing short lengths of wood together) makes use of wood that traditionally
would have been disposed of as waste. Finger-jointed products are generally straighter and stronger than solid
wood; you won’t have to reject and waste warped or split boards. For structural use, they are acceptable for
longitudinal compression loads only.

5-55 Use cementitious foam-formed walls with flyash concrete


3 POINTS

In addition to energy savings, this method also represents an opportunity to use a waste product, flyash, in
standard building material, which coincidentally offers superior performance. Flyash waste from coal burning has

155
been shown to improve the strength of concrete (see Action item 5-57, Use flyash or blast furnace slag for 25% by
weight of cementitious materials for all concrete (20% for flat work).

In addition, some ICF systems are made with waste wood. The system offers significant savings in labor by
combining framing, insulating, and sheathing. Less waste is produced because of the system’s flexibility (the
forms can be cut to any shape). Additionally, many systems have “studs” built in so there’s something to nail or
screw to, and sheetrock may be attached directly to the foam’s interior surface. Exterior siding material, such as
wood, vinyl, brick, or stucco, can be easily attached.

Foundation

5-56 Use regionally produced block


1 POINT

Locally produced materials are generally considered to be materials produced within the Pacific Northwest
region, or within a 500 mile radius. Points are awarded for using locally produced block in recognition that this
strategy reduces the amount of fuel used to transport material to the site.

Resources
Ask your local supplier and ask about the origin of the material.

5-57 Use flyash or blast furnace slag for 25% by weight of cementitious materials for
all concrete (20% for flat work)
3-6 POINTS

Fly ash is a by-product of burning coal for electricity production. It can be added to concrete slabs and foundations
mixes as a substitute for up to 60% of the Portland cement mixture. The general rule of thumb recommends 15-
30%. It has been shown to improve the strength of concrete as well as increase its workability. Be advised that
concrete with fly ash content sets up more slowly, but it is easy to work with and has a slightly smoother finish. It
is readily available and involves no added cost.

Blast Furnace Slag is a coproduct of iron production, commonly used as feedstock for steel production. Pelletized
blast furnace slag can be used as a lightweight mineral admixture in blended cement for durable concrete
structures. Blast furnace slag reduces the risk of damage caused by Alkali-silica Reaction, reinforcement corrosion
and sulfphate. This concrete material has extended the lifespan of buildings from 50 to 100 years. Using blast
th th
furnace slag also requires 1/5 of the energy needed to produce Portland cement and produces less than 1/10 the
carbon dioxide emissions of Portland cement generation.

Resources
A major distributor of flyash is ISG Resources in Centralia: 888-333-5546. Check with your local ready-mix
company for suppliers. Also contact, local supplier:

• ISG Resources, Inc., Mercer Island, WA. 800-426-5171 or www.flyash.com.


For more information about using flyash in concrete and its performance consult the following:

• “Fly Ash Improves Concrete, Reduces Pollution,” Journal of Light Construction, July 1999. Available from
the JLC Bookstore: 800-859-3669, fax 802-434-4467, or online at www.jlconline.com/bookstore.
• “The Fly Ash Revolution: Making Better Concrete with Less Cement,” Environmental Building News, June
1999. Brattleboro, VT, 1999. 802-257-7300 or www.buildinggreen.com.

156
5-58 Use recycled concrete, asphalt, or glass cullet for base or fill
2 POINTS

When using this technique, grind concrete, asphalt, or glass cullet properly to meet base or fill specification. When
ground to specs, the materials compact nicely to form a stable base. Get a sample from the supplier for your
excavator crew to approve.

Resources
Depending on current supply and price, recycled concrete, asphalt, or glass cullet may be cost-effective options.
Consult the Washington Department of Transportation (WADOT) specifications for using these materials (see
BUILT GREEN Resource Library).

See your pavement supplier for recycled concrete and asphalt options. There are also mobile concrete crushers,
see your local phone book for vendors. They can crush concrete on site to spec.

Glass cullet is an excellent alternative for fill. See the BUILT GREEN Resource Library for a copy of the WSDOT
specifications. Post-consumer glass is primarily clear, amber, and green bottle glass. Post-industrial glass is a
by-product of manufacturing activity. It is generally cleaner and more uniform in size.

Doors

5-59 Use doors that are recycled-content or certified as sustainably produced (FSC,
CSA Intl., or American Tree Farms System)
1 POINT

For further information and comparison of certification systems, visit www.certifiedwood.org/search-


modules/CompareCertSystems.asp.

5-60 Use domestically-grown and manufactured wood interior doors


2 POINTS

Domestically grown wood interior doors offer the same performance without compromising limited and
endangered hardwood species stock. They also represent an opportunity to reduce embodied energy through
minimizing the transportation impact.

Finish Floor

5-61 Hardwood flooring from third-party certified, sustainably harvested sources,


locally harvested or re-used lumber
4 POINTS

5-62 Use recycled-content underlayment products


2 POINTS

Using underlayment products below wood, tile, resilient flooring, or carpet and carpet cushion provides a level
surface, covers cracks, and helps insulate floors from sound transmission and some heat loss. Standard
particleboards are traditionally used for the purpose of underlayment, even though they are known to be the
157
primary source of formaldehyde gas in new homes. Exterior grade plywood or no added urea formaldehyde wood
fiberboard with recycled-content is a superior choice for underlayment. OSB does not apply unless it is certified
with recycled content. Other environmentally preferable materials for flooring underlayment include natural cork
and options made with recycled rubber, paper, jute hemp and/or agricultural fiber. (See Section Four, Health and
Indoor Air Quality, Action item 4-38 , Use plywood and composites of exterior grade or with no added urea
formaldehyde (for interior use).

Resources
Ask your local flooring supplier. Some manufacturers to consider are:

• Homasote, West Trenton, NJ. 800-257-9491. 440 Sound Barrier, 440 Carpetboard and Comfort Base. The
440 materials are high-density fiberboard panels made from 100% recycled wastepaper and a
formaldehyde-free paraffin binder. Comfort Base is specifically designed for use over a concrete slab.
Other brands offer further environmental benefits, consider:

• Medite Corporation, Medford, OR. 800-676-3339. Medex and Medite II MDF are formaldehyde-free
alternatives for underlayment as well as cabinet frames, countertops, interior door and window casings,
and trim. Available through your local supplier.
• U.S. Gypsum Co., 800-874-4968. Fiberock brand gypsum fiber underlayment is a fiber-reinforced gypsum
panel specially designed for use in residential construction as an underlayment for vinyl, carpeting,
hardwood flooring and ceramic tile (dry areas only).

5-63 Use recycled-content vinyl flooring


1 POINT

Vinyl flooring is a commonly used material and often preferred for economy and durability. It is not
environmentally preferred, however, due to the manufacturing process that creates air pollution problems,
impacts from VOCs off-gassing during construction and occupancy, and the fairly limited potential for recycling
the material after it has been used as flooring.

Vinyl Composition Tile (VCT), on the other hand, contains recycled-content and is preferred over sheet vinyl
because VCT contains fewer VOCs and other chemicals and damaged tiles can be replaced individually.

5-64 No vinyl flooring


4 POINTS

Vinyl flooring is a commonly used material and often preferred for economy and durability. It is not
environmentally preferred, however, due to the manufacturing process that creates air pollution problems,
impacts from VOCs off-gassing during construction and occupancy, and the fairly limited potential for recycling
the material after it has been used as flooring.

As an alternative, Vinyl Composition Tile (VCT) contains recycled-content and is preferred over sheet vinyl
because VCT contains fewer VOCs and other chemicals and damaged tiles can be replaced individually.

Resources
Ask your local flooring supplier for vinyl flooring with recycled content. Some manufacturers to consider are:

• Marmoleum, by Forbo
• Amtico. 800-268-4260. Stratica, a low VOC and chlorine-free, durable alternative to vinyl. For local
information call 425-453-6190.

158
5-65 On more than 250 square feet, use rapidly renewable flooring products with a
ten-year harvest cycle or shorter (excluding carpet)
3 POINTS

Cork and bamboo are examples of rapidly renewable flooring resources.

Cork is sustainable because the bark is harvested and the tree is left to regenerate more bark. The bark is
harvested on an eight-year cycle. Cork flooring is durable, sound absorbing, and naturally moisture-, mold-, and
rot-resistant.

Bamboo is sustainable because it can be harvested on a six to eight year cycle. Bamboo flooring is a very durable
and dimensionally stable material. The short regeneration time of bamboo provide justification for specifying
bamboo flooring instead of wood.

There can also be indoor air quality advantages to using natural materials, such as less off-gassing due to fewer or
no chemicals used in the manufacturing process. Check product Material Safety Data Sheet (MSDS) to make sure
adhesives and other flooring components do not contain hazardous materials, such as formaldehyde.

Resources
Ask your supplier for cork or bamboo flooring and/or plant-based finishes.

5-66 Use recycled-content carpet pad


1 POINT

A variety of options are available for cost-competitive, resource-efficient carpet padding. In general, these
products have been found to be very resilient and possess good performance characteristics.

Carpet padding may be made from several recycled-content materials including nylon and polypropylene waste
from carpet manufacturing and recycled tire rubber and rebound urethane, reprocessed from virgin prime
urethane products.

5-67 If installing carpet, use recycled-content or renewed carpet


3 POINTS

A variety of cost-competitive resource-efficient carpet options are available. In general, these products have been
found to be very resilient and possess good performance characteristics.

Recycled-content carpets may include plastic yarns produced from recycled pop bottles or recovered fibers from
recycled textiles.

Renewed carpet is used carpet that has been cleaned and restamped. A variety of attractive renewed styles are
available. Ask your supplier.

Wool carpet is another resource efficient option that is renewable, biodegradable, naturally fire and stain
resistant, and colorfast; see Action item 4-22, Install Natural Fiber Carpet (e.g. Wool).

Resources
Regardless of which carpet you select, make sure it has the Carpet and Rug Institute’s (CRI) Green Label. Your local
carpet suppliers or installers may have resource-efficient products they carry or have installed. Compare their
suggestions with the products and information available through these resources:

• Mohawk Carpet by Mohawk Industries, Armuchee, GA. 800-241-7597. Carpets contain 100% recycled
plastic fibers from used pop bottles (PET).
159
• Nature’s Carpet, 100% natural wool carpet manufactured without toxic chemicals. Colin Campbell and
Sons, Vancouver, BC: 800-667-5001.
• Shaw Industries, 800-833-9665. Manufactures Philadelphia Carpets and E & B Carpets, made from 50-70%
post-consumer PET.

5-68 Use replaceable carpet tile


1 POINT

Carpet tiles are a sustainable material choice because they are often made of recycled fiber content. In addition,
one or more tiles can be replaced if damaged without having to replace an entire wall-to-wall carpet. Carpet tiles
allow easy access to wiring or plumbing located under the floor. They can be used in high and low traffic areas and
require less time and fewer tools than traditional carpet. They can be installed using either special adhesive or
double-faced tape or can be ordered with self-stick backing. Carpet tiles come in many thicknesses, patterns and
colors.

Resources
• Patcraft recyclable carpet tiles
• Interface Flooring System. 800-281-FLOR. www.interfaceflor.com. Offers recyclable nylon, hemp and
wool carpet tiles.

5-69 Use 40% recycled-content hard surface tile, 100 square feet minimum
3 POINTS

Several manufacturers make glass, ceramic, and porcelain tiles with recycled-content. These tend to be pricey, but
are durable and offer an attractive opportunity to highlight (and market) the use of an environmentally friendly
material to your client or market. Acceptable applications to qualify for this credit include: flooring, countertops,
floors, shower surrounds.

Resources
Your local supplier may carry a recycled-content ceramic tile that meets your needs. Listed below are several
manufacturers who make ceramic tile with recycled content:

• AMDEC, Portland, OR. 503-297-5933 or e-mail mfarrier@teleport.com. Manufactures Silica Select tiles
from 100% recycled post consumer/post industrial glass. Indoor/outdoor applications.
• Stoneware
• Summitville Tiles, Summitville, OH. 330-223-1511. Makes Cobblestones, Imperva, Imperva Granite, and
MorganMates from a by-product of feldspar mining. Indoor/outdoor use. The company also reuses 100%
of its solid wastes.
• Terra Green Technologies, Richmond, IN. Manufactures Traffic Tile, made with 58% recycled auto
windshield glass with some mirror and bottle glass. Pricey but very high quality; indoor/outdoor uses.
Company also makes Terra Classic from recycled glass and ceramic tile, for residential floors, walls, and
countertops. Both are available through E-Spec in Oakland, CA. 510-536-2600.
• Tile Cera, Clarksville, TN. Makes tiles for floor and wall applications that include a small amount of
in-house scrap and cull tile. Company is notable for its closed-loop manufacturing system, which
eliminates tile solid waste and recycles water used in the manufacturing process within the plant. Tiles can
be sourced from the distributor, Santa Catalina Inc. California: 510-351-7095.
• Versatile and Master Tile Products, Canton, OH. Sells Enviroquarry tiles made with recycled content.
330-493-1272.

160
5-70 Use natural linoleum
3 POINTS

Linoleum is made from all-natural materials and is a durable, low-maintenance flooring made of linseed oil, pine
resin, sawdust, cork dust, limestone, natural pigments, and jute backing. Linoleum does not contain significant
petroleum-based products or chlorinated chemicals, as does vinyl flooring, which is often mistakenly referred to
as linoleum. From a raw materials standpoint, linoleum is an outstanding product. All of its ingredients are
minimally processed and commonly available and it is biodegradable.

Resources
Check with your local flooring supplier.

• Forbo Marmoleum

5-71 Use recycled-content glass, ceramic, or porcelain tile for 10% of total floor area
3 POINTS

5-72 Use flooring that is third-party certified sustainably harvested wood that meets
the Tier 1 requirements outlined in the handbook, 50% minimum
5 POINTS

To receive credit for this Action item, the flooring selected for the project must meet Certified Wood Products Tier
1 Requirements listed under Design and Material Selection, Wood Certification Guideline for Section Five. (See Table
5-1, at the beginning of the Design and Material Selection section.)

Currently, only the Forest Stewardship Council (FSC), a voluntary, market-based, certification organization, meets
Tier 1 requirements. It is one of few programs that require a chain of custody for certification. FSC sets standards
for sustainable forestry practices and depends on independent companies for third-party certification of
forestlands. It evaluates and monitors certifiers to ensure public credibility.

Resources
See Resources listed for 5-45, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 1 Requirements Outlined in the Handbook, 50% Minimum

5-73 Use flooring that is third-party certified sustainably harvested wood that meets
the Tier 2 requirements outlined in the handbook
1 POINT

For credit for this Action item, use flooring that meets Certified Wood Products Tier 2 Requirements listed under
Design and Material Selection, Wood Certification Guidelines for Section Five.

Currently, there are no programs that meet these criteria, however, a few are expected to on-line soon.

Resources
See Resources listed for 5-46, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 2 Requirements Outlined in the Handbook.

5-74 Use durable/spot repairable floor finish

161
1 POINT

Spot repairable floor finishes, also known as penetrating oil or wax finishes, penetrate into wood fibers unlike
products like polyurethane, which coat the floor with a plastic film. As polyurethane wears down over time,
everything must be removed from the floor so screening and recoating can be done. This inconvenient process
prevents many floors from being properly maintained, sacrificing the life span of the wood floor. If a polyurethane
finish wears down too far, the floors need to be sanded down to bare wood. Most wood floors can only be sanded
3 or 4 times. In contrast, a spot repairable finish can be touched-up in only areas that need it. This is more
convenient for the homeowner and also minimizes the need for sanding.

Resources
• OSMO Polyx Oil

5-75 Use concrete slab or sub-floor as a finished floor in living space


2 POINTS

If you have already poured a concrete slab or sub-floor, the embodied energy of this material has already been
incorporated into the project. Consider using this as a finished floor for a very durable and stylish look while
greatly minimizing additional material use.

5-76 A minimum of 85 percent of installed hard-surface flooring is in accordance with


the emission concentration limits of CDPH 01350 as certified by a third-party
program, such as the Resilient Floor Covering Institute, or GREENGUARD
6 POINTS

Interior Walls

5-77 Use drywall with at least 30% recycled-content gypsum


1 POINT

Drywall manufactured with recycled gypsum or flue gas substitute is commonly available at most building
material suppliers and is cost-competitive with conventional drywall. However, it must be specified if you want to
use it (in other words, it is not automatic).

Resources
Check with your local supplier to see if they carry drywall with recycled-content gypsum (including post-consumer
gypsum collected from construction and demolition projects and processed locally). If they do not, they should be
able to source the following two products:

• G-P GyProc (formerly made by Domtar), manufactured and distributed by GP Gypsum, Tacoma. 800-366-
8276 or 253-627-2100. Contains up to 12% of recycled scrap wallboard and byproduct gypsum.
• HardiRock, manufactured and distributed by James Hardie Gypsum. 800-426-3669. Includes 7-10%
post-consumer gypsum.
The Walls and Ceilings Association in Portland should also be able to help you locate a supplier of recycled-content
gypsum drywall. 503-295-0333.

162
5-78 Use recycled or “reworked” paint and finishes
2 POINTS

Companies are marketing recycled paint on a regional basis. Recycled paint was formerly offered only in limited
colors and styles, but the selection is expanding, and recycled paint is usually cheaper than its virgin counterpart.
Keep in mind that you will not want to use these paints in frequently occupied living spaces, such as bedrooms,
children’s playrooms, or in home for individuals with chemical sensitivities. (See Action item 4-25, Optimize Air
Quality in Family Bedrooms to Basic or Advanced Level (Perform All Measures Listed in Handbook for Basic or
Advanced Level), and Action item 4-42, Use Only Low-VOC/Low-Toxic Interior Paints and Finishes for Large Surface
Areas.

Resources
Your local paint supplier may carry recycled or reworked paints. Also see:

• Builders Guide to Paints and Coatings, NAHB Research Center, Upper Marlboro, MD. 800-638-8556 or
www.nahbrc.org.

5-79 Use recycled newspaper or cork expansion joint filler


1 POINT

Cork expansion joint filler is strong, light weight, flexible, acid-resistant, waterproof and regains up to 95% as joint
expansion takes place. This material is made from cork, a rapidly renewable material. It is preformed from
granulated cork particles, bonded with an insoluble phenolic resin, and molded under heat and pressure.

100% recycled newsprint is being used to manufacture pre-molded wood fiber strips for use in concrete and
masonry joints. Suitable for any building construction application where non-bituminous contraction joint is
applicable, concrete floors, walls, retaining walls, gutters, curbs, pavement, and swimming pool aprons. The
natural grey color blends with concrete to further enhance the appearance of the finished job.

Resources
• Homex 300 Expansion Joint Fillers, Homasote Company. 100% recycled newsprint joint filler.
www.sweets.construction.com/mfg/1558/P9720.htm.
• Cork Expansion Joint Filler, available from several suppliers on the web, or ask your local supplier.

5-80 Use natural wall finishes, e.g. lime paint, clay


2 POINTS

Natural finishes refer to lime paints, milk paints and clays free of plastics and acrylics and low in solvents and
VOCs.

Lime paint is an interior or exterior finish that contains slaked lime, clay, marble dust, earth pigments, natural glue
and water. Lime paint can be applied to a variety of surfaces including wood, drywall and masonry.

Milk paint is a durable, economical, matte finish made of milk protein, lime and clay. Milk paint dries quickly
without the solvents and VOCs of traditional paint.

Natural clay plaster is an interior, trowel-on finish that comes in a wide variety of colors and can be highly polished
or heavily textured. It contains clay, marble dust, borax and earth pigments. Clay plaster is mold resistant,
hypoallergenic and low toxic.

163
5-81 Reduce interior walls through open plan for kitchen, dining, and living areas
2 POINTS

This strategy reduces material use and cost for walls, and creates an adaptable space that allows for maximum
daylighting, occupant interaction, and natural ventilation. It’s frequently used, but not necessarily known as a
green building technique.

Exterior Walls

5-82 Use recycled-content sheathing


1 POINT

Sheathing can comprise a significant portion of the material used in a project. Therefore, choosing a sheathing
product made with a minimum of 50% pre- or post-consumer recycled-content can have a significant impact on
resource conservation. Many options are available including products made from certified sustainable wood.

5-83 Use siding with reclaimed or at least 15% recycled material on at least 75% of
solid wall surface
1 POINT

Three types of siding currently include recycled-content: metal, vinyl (to a small degree), and fiber cement
composites. These products also offer durable and low-maintenance alternatives to wood siding. Metal offers the
greatest opportunity to use post-consumer recycled-content in your project. Aluminum or steel siding products
contain high percentages of recycled metal—up to 100%. The scrap is also recyclable.

Vinyl siding can include a small percentage of post-industrial scrap in the manufacturing process. However, PVC is
difficult to recycle, and there are no vinyl siding products with post-consumer vinyl at this time.

Fiber-cement composites are also resource efficient and offer a very good fire rating when compared to wood or
metal siding. In addition to durability and low maintenance benefits, the wood fiber in these products is reclaimed
from wood processing waste. It can also be harvested from small diameter fast-growing tree species.

Other reclaimed options include building salvage materials.

Resources
Ask your local supplier or try:

Reclaimed:

• Blue Log Lumber, Mendocino, CA. 707-937-0918. They salvage and remill redwood into siding, dimensional
lumber, and decking.
Reclaimed: Composite

• James Hardie Building Products, Fontana, CA. 800-426-4051. Hardiplank Lap Siding and Hardipanel
Vertical Siding are manufactured with Portland cement, ground sand, and cellulose fiber. Available from
local suppliers.
• FCP, Inc, Blandon, PA, 877-CEMPLANK (236-7526). Cemplank fiber-cement plank siding is low
maintenance and comes with a limited lifetime warranty.
Recycled:

164
• Cladwood, Oregon City, OR. 800-547-6633. Cladwood siding panels have a phenol-formaldehyde-bonded
particleboard core with resin-impregnated recycled paper overlays . Recycled content ranges from 16-26%
by weight with roughly 10% post-consumer content. 20 year warranty.
• AmeriMark, Inc., Olive Branch, MS. 800-345-3390 or www.Amerimark.com. Alsco Siding has a recycled
plastic substrate and a virgin vinyl exterior finish layer.

5-84 No vinyl siding or exterior trim


2 POINTS

Vinyl siding or exterior trim is a commonly used material and often preferred for economy and presumed
durability. It is not environmentally preferred, however, due to the toxic manufacturing process required and
limited potential for recycling the material after it has been used as siding or trim.

5-85 Wood siding is 100% FSC-certified or locally harvested or milled


6 POINTS

5-86 Use 50-year warranted siding product


2 POINTS

Minimizing the need to replace any siding product offers a maximum consumer benefit to the homeowner, in
addition to the obvious environmental impact. Many of the fiber-cement composites offer a 50-year warranty. Ask
your local supplier for this and other options.

Resources
• James Hardie Building Products, Fontana, CA. 800-426-4051. Hardiplank Lap Siding and Hardipanel
Vertical Siding are manufactured with Portland cement, ground sand, and cellulose fiber. Available from
local suppliers.
• FCP, Inc, Blandon, PA, 877-CEMPLANK (236-7526). Cemplank fiber-cement plank siding is low
maintenance and comes with a limited lifetime warranty.
For metal and vinyl siding, talk to your local supplier/installer to make sure you get the highest amount of
recycled-content available.

5-87 Use wood siding that is third-party certified sustainably harvested wood that
meets the Tier 1 requirements outlined in the handbook, on at least 20% of solid
wall surface
5 POINTS

To receive credit for this Action item, the wood siding selected for the project must meet Certified Wood Products
Tier 1 Requirements listed under Design and Material Selection, Wood Certification Guideline for Section Five. (See
Table 5-1, at the beginning of the Design and Material Selection section.)

Currently, only the Forest Stewardship Council (FSC), a voluntary, market-based, certification organization, meets
Tier 1 requirements. It is one of few programs that require a chain of custody for certification. FSC sets standards
for sustainable forestry practices and depends on independent companies for third-party certification of
forestlands. It evaluates and monitors certifiers to ensure public credibility.

Resources

165
See Resources listed for 5-45, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 1 Requirements Outlined in the Handbook, 50% Minimum

5-88 Use wood siding that is third-party certified sustainably harvested wood that
meets the Tier 2 requirements outlined in the handbook, on at least 20% of solid
wall surface
1 POINT

For credit for this Action item, use wood siding that meets Certified Wood Products Tier 2 Requirements listed
under Design and Material Selection, Wood Certification Guidelines for Section Five.

Currently, there are no programs that meet these criteria, however, a few are expected to on-line soon.

Resources
See Resources listed for 5-46, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 2 Requirements Outlined in the Handbook.

5-89 Use salvaged masonry brick or block, 50% minimum


2 POINTS

Several private suppliers offer salvaged brick and block. Check the resources section for a list of suppliers. Also
consider establishing a reuse policy for the masonry brick or block you generate during construction.

Resources
See your local supplier of brick masonry or block and ask for reclaimed materials. Also look at jobsites for discards.
Salvage yards may also stock these materials, including:

• Reusable Building Materials Exchange: www.rbme.com, (see the Participating Jurisdictions). An online,
user-driven website. Features descriptions of items, contact name, telephone number, e-mail address, and
any costs or delivery information. Listings are free.

5-90 Use regionally-produced stone or brick


2 POINTS

“Regionally produced” materials are generally considered to be produced within the Pacific Northwest region,
ideally in WA, OR, or ID.

Use locally quarried, indigenous stone that is cut and polished locally. Use of regional materials helps keep
material transport costs down, reinforces a regional aesthetic, and supports the local economy.

Resources
Ask your local supplier and ask about the origin of the material.

Windows

5-91 Use wood / fiberglass / finger jointed / composite wood windows


5 POINTS

166
Manufacturers have developed new window frame materials from a composite of recycled polyvinyl chloride
(PVC) or high-density polyethylene (HPDE) plastics and waste wood fiber. Combining the two materials creates a
product that has important advantages over both wood and vinyl windows: the dimensional stability and thermal
performance of wood, and the uniformity and decay resistance of plastics. The cost of wood/plastic composite
windows is often less than that of wood or vinyl.

Wood/plastic composites consist primarily of waste sawdust and scrap PVC generated in the production of wood
and vinyl windows, or with PVC, from post-consumer bottle waste. Wood content ranges from 40 to 70%,
depending on the manufacturer. According to recent tests, the frames have roughly the same energy
performance as solid wood, but perform slightly better than vinyl window frames.

Wood fiber increases the dimensional stability of the composite material. Dimensional stability is commonly a
problem with PVC plastic frame materials. The composite coefficient of expansion more closely matches glass
than vinyl and helps keep the seal between the frame and glass intact for long-term performance. Further, the
composite does not absorb moisture and will not swell like wood.

Windows made of fiberglass produce the highest energy efficiency and minimal environmental impact. Fiberglass
requires less energy to produce into a final product than PVC or aluminum. It reduces condensation, won’t
contract or expand like wood, and is least likely to crack, corrode, rot, or leak.

Traditionally, the finest clear-grained wood has been used for doors and window frames. However, the availability
of stable, clear, mature wood has declined. As a result, the industry has responded by developing finger-jointed
wood products—taking smaller scraps of lower value wood and edge gluing them together, covered by
top-quality wood veneers on the finish surface.

Look for window manufacturers that offer windows that qualify for the ENERGY STAR program.

Resources
Ask your local supplier and consider the following manufacturers:

• Andersen Windows, Cottage Grove, MN. 800-426-7691 or www.andersenwindows.com. Their Renewal™


line of windows features frames and sashes made of Fibrex, a post-industrial wood –and-PVC-waste
composite with a coextruded virgin PVC exterior coating. Low-e (2) is offered standard in all products.
• Pella Corporation, Pella, IA. 800-847-3552 or www.pella.com/frontDoor. Pella’s SmartSash® wood
windows and doors are made from ponderosa pine, eastern white pine, sugar pine, and some white fir. The
exterior is clad with recycled aluminum finished with a baked-on EnduraClad™ coating.

5-92 Use locally-produced windows


1 POINT

5-93 Use wood windows that are third-party certified sustainably harvested wood that
meets the Tier 1 requirements outlined in the handbook
5 POINTS

To receive credit for this Action item, the windows selected for the project must meet Certified Wood Products
Tier 1 Requirements listed under Design and Material Selection, Wood Certification Guideline for Section Five. (See
Table 5-1, at the beginning of the Design and Material Selection section.)

Currently, only the Forest Stewardship Council (FSC), a voluntary, market-based, certification organization, meets
Tier 1 requirements. It is one of few programs that require a chain of custody for certification. FSC sets standards

167
for sustainable forestry practices and depends on independent companies for third-party certification of
forestlands. It evaluates and monitors certifiers to ensure public credibility.

Resources
See Resources listed for 5-45, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 1 Requirements Outlined in the Handbook, 50% Minimum

5-94 Use wood windows that are third-party certified sustainably harvested wood that
meets the Tier 2 requirements outlined in the handbook
1 POINT

For credit for this Action item, use dimensional lumber that meets Certified Wood Products Tier 2 Requirements
listed under Design and Material Selection, Wood Certification Guidelines for Section Five.

Currently, there are no programs that meet these criteria, however, a few are expected to on-line soon.

Resources
See Resources listed for 5-46, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 2 Requirements Outlined in the Handbook.

• Window & Door. www.windowanddoor.net/pastarticles.php?id=372. Materials sourcing and information


website of Window & Door Magazine.

Cabinetry and Trim

Resources
• Window & Door. www.windowanddoor.net/pastarticles.php?id=372. Materials sourcing and information
website of Window & Door Magazine. Lists green fenestration products made with certified wood.

Trim:
Although commonly used MDF trim materials may be less costly, they require stringent protection from
fluctuations in heat and humidity during transit between manufacturing facility and the job site. This can be
difficult to control and may result in excessive shrinkage, cracking and bowing that creates difficult installs and
product waste. MDF trim pieces also lack lateral strength, offgas if bonded with urea formaldehyde, and create
noxious dust during cutting.

Solid wood and urethane trim products are proving to be the highest quality, durable and long lasting trim option.

5-95 Use regional trim products, 50% minimum


1 POINT

“Regionally” materials are generally considered to be produced within the Pacific Northwest region, ideally in WA,
OR, or ID.

Use of regional materials helps keep material transport costs down, reinforces a regional aesthetic, and supports
the local economy.

Resources
See local suppliers and ask about origin of materials.

168
5-96 Use trim that is third-party certified sustainably harvested wood that meets the
Tier 1 requirements outlined in the handbook, 50% minimum
3 POINTS

To receive credit for this Action item, the trim selected for the project must meet Certified Wood Products Tier 1
Requirements listed under Design and Material Selection, Wood Certification Guideline for Section Five. (See Table
5-1, at the beginning of the Design and Material Selection section.)

Currently, only the Forest Stewardship Council (FSC), a voluntary, market-based, certification organization, meets
Tier 1 requirements. It is one of few programs that require a chain of custody for certification. FSC sets standards
for sustainable forestry practices and depends on independent companies for third-party certification of
forestlands. It evaluates and monitors certifiers to ensure public credibility.

Resources
See Resources listed for 5-45, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 1 Requirements Outlined in the Handbook, 50% Minimum

5-97 Use trim that is third-party certified sustainably harvested wood that meets the
Tier 2 requirements outlined in the handbook, 50% minimum
1 POINT

Select trim from certified or sustainable sources. Although there may be a slight cost premium associated with
this choice, it allows you to contribute to a sustainable enterprise and ensure protection of endangered hardwood
forests.

For credit for this Action item, use dimensional lumber that meets Certified Wood Products Tier 2 Requirements
listed under Design and Material Selection, Wood Certification Guidelines for Section Five.

Currently, there are no programs that meet these criteria, however, a few are expected to on-line soon.

Resources
See Resources listed for 5-46, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 2 Requirements Outlined in the Handbook.

5-98 Use finger-jointed or MDF trim with no added urea formaldehyde, 90% minimum
3 POINTS

Since the availability of stable, clear, mature wood has declined, any application, which requires straight,
knot-free wood is affected. As a result, the industry has responded by developing finger-jointed wood products—
taking smaller scraps of lower value wood and edge-gluing them together, covered by top-quality wood veneers
on the finish surface. Interior trim is an excellent application for this new product; it offers improved product
consistency and durability, while at the same time uses harvested wood fiber more efficiently.

MDF is commonly bonded with urea formaldehyde adhesives. These materials can off-gas in the home and create
noxious dust during cutting. Choose products with no added urea formaldehyde.

Resources
• Builder News. 2105 C Street, Vancouver, WA 98663. 360-906-0793.
www.buildernewsmag.com/viewnews.pl?id=123. Website for building trade magazine. Technical
information on high quality molding and millwork.

169
• Toolbase Services. 400 Prince George’s Blvd., Upper Marlboro, MD 20774. www.toolbase.org/Best-
Practices/Failure-Prevention/fiberboard-trim-shrinkage. Technical information website for building
materials. Technical information on fiberboard trim.
See your local supplier.

5-99 Use wood veneers that are third-party certified sustainably harvested wood that
meets the Tier 1 requirements outlined in the handbook, 50% minimum
1 POINT

To receive credit for this Action item, the wood veneers selected for the project must meet Certified Wood
Products Tier 1 Requirements listed under Design and Material Selection, Wood Certification Guideline for Section
Five. (See Table 5.1, at the beginning of the Design and Material Selection section.)

Currently, only the Forest Stewardship Council (FSC), a voluntary, market-based, certification organization, meets
Tier 1 requirements. It is one of few programs that require a chain of custody for certification. FSC sets standards
for sustainable forestry practices and depends on independent companies for third-party certification of
forestlands. It evaluates and monitors certifiers to ensure public credibility.

Resources
See Resources listed for 5-45, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 1 Requirements Outlined in the Handbook, 50% Minimum

Cabinets:
Select cabinet materials from certified or sustainable sources. Although there may be a slight cost premium
associated with this choice, it allows you to contribute to a sustainable enterprise and ensure protection of
endangered hardwood forests.

5-100 Use cabinetry made of a rapidly-renewable product


2 POINTS

5-101 Use regional products, 90% minimum


2 POINTS

Resources
• Neil Kelly Cabinets, offers FSC-certified cabinet doors upon request, see their website for a list of
authorized dealers, http://www.neilkellycabinets.com/coverpage.htm or contact (503) 335-9207. Portland.
OR.
• Breathe Easy Cabinetry, a division of Greenway Cabinetry, Inc. has introduced its new line of healthy,
green cabinetry

5-102 Use wood that is third-party certified sustainably harvested wood that meets the
Tier 1 requirements outlined in the handbook, 50% minimum
3 POINTS

170
Select wood from certified or sustainable sources. Although there may be a slight cost premium associated with
this choice, it allows you to contribute to a sustainable enterprise and ensure protection of endangered hardwood
forests.

To receive credit for this Action item, the wood selected for the project must meet Certified Wood Products Tier 1
Requirements listed under Design and Material Selection, Wood Certification Guideline for Section Five. (See Table
5-1, at the beginning of the Design and Material Selection section.)

Currently, only the Forest Stewardship Council (FSC), a voluntary, market-based, certification organization, meets
Tier 1 requirements. It is one of few programs that require a chain of custody for certification. FSC sets standards
for sustainable forestry practices and depends on independent companies for third-party certification of
forestlands. It evaluates and monitors certifiers to ensure public credibility.

Resources
• Neil Kelly Cabinets, offers FSC-certified cabinet doors upon request, see their website for a list of
authorized dealers, http://www.neilkellycabinets.com/coverpage.htm or contact (503) 335-9207. Portland.
OR.

5-103 Use wood that is third-party certified sustainably harvested wood that meets the
Tier 2 requirements outlined in the handbook, 50% minimum
1 POINT

For credit for this Action item, use dimensional lumber that meets Certified Wood Products Tier 2 Requirements
listed under Design and Material Selection, Wood Certification Guidelines for Section Five.

Currently, there are no programs that meet these criteria, however, a few are expected to on-line soon.

Resources
See Resources listed for 5-46, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 2 Requirements Outlined in the Handbook.

5-104 Alternative materials used for cabinetry with low or no VOCs - recycled content
stainless steel, solid wood, glass, etc, or construction methods - pantry use, open
shelves, etc.
4 POINTS FOR USING ALTERNATIVE MATERIALS
+3 POINTS FOR USING DESIGN AND CONSTRUCTION METHODS, E.G. PANTRY USE, OPEN SHELVES

5-105 Use cabinet casework and shelving constructed of agricultural fiber with no-
added urea formaldehyde
2 POINTS 50%
3 POINTS 90%

Strawboard and wheatboard are suitable material choices for this credit. These materials are readily available and
provide a good alternative choice, without off-gassing concerns or the use of toxic chemicals in its manufacturing
process.

Countertops:

171
5-106 Use countertops that are third-party certified sustainably harvested wood that
meets the Tier 1 requirements outlined in the handbook
2 POINTS

Use countertops salvaged from projects or those made of untreated salvaged woods such as reclaimed butcher-
block products. These are minimally processed, natural and can be reused at the end of their lifespan. Look for
products with no added urea formaldehyde.

Third party certified wood countertops are also an option. Look for untreated wood products certified through
organizations such as FSC or SCS.

There are many countertop options available in recycled materials. Paper composite countertops are made of
paper pressed in a resin binder and can be found with high recycled content and low-VOC resins. Products come in
a variety of colors and thicknesses and are easy to maintain and repair. Recycled glass countertops come in the
form of tiles and crushed glass set in cement binders. One hundred percent recycled aluminum tiles are also on
the market.

5-107 Counter tops of concrete, domestic stone, tile with recycled content, recycled
paper products and cabinets and countertop underlayment of wheatboard or
non-formaldehyde particle board
4 POINTS

Roof

5-108 Use recycled-content roofing material


2 POINTS

Traditional cedar shakes, although appealing for their textural qualities, only offer a 10-15 year life span in most
climates. Several new composite options are available that provide lower maintenance along with durability.
Many of these options include recycled-content or reclaimed materials: fiber-cement composites, asphalt
shingles, plastic shakes, ridged sheet material made with fiber and asphalt, and metal shingles.

Fiber-cement composite slates are lightweight, long lasting, and fireproof. They offer an efficient use of wood
fiber and can be used on standard roof structures. Asphalt shingles contain recycled “mixed” waste paper or
reclaimed mineral slag resulting in 20% to 25% recycled-content. Roof panels made from recycled plastic resins
provide a lightweight roofing alternative in additional to recycled aluminum shingles which may contain up to
100% recycled-content.

Resources
Ask your local supplier and consider the following manufacturers:

• Ondura Corporation, Fredericksburg, VA. 800-777-7663 or www.ondura.com. Their corrugated asphalt


roofing is composed of 50% asphalt and 50% cellulose fiber (by weight). The cellulose fiber is 100%
post-consumer mixed paper wastes.
• Crowe Building Products, Ltd., Hamilton, ON, Canada. 905-529-6818 or www.authentic-roof.com.
Authentic Roof is a slate lookalike with recycled polymers and rubber.
• EcoStar, Chicago, IL. 800-572-7672 or www.ecostarinc.com. Majestic Slate is a 100% recycled and
recyclable lightweight slate tile made of industrial rubber and plastics.

172
• Re-New Wood, Inc., Wagoner, OK. 800-420-7576. Eco-shake is a 100% recycled PVC (vinyl) and reclaimed
wood roofing product. It has the look of a wood shake in four colors.
• Zappone Manufacturing, Spokane, WA. 800-285-2677 or www.zappone.com. Recycled Metal Shingles are
made from either 85% recycled copper (75% post-consumer) or 100% post-consumer recycled aluminum.

5-109 Use 40-year warranted roofing material


2 POINTS

Using durable materials with long-lasting value helps prevent the need for replacement – an asset to the
homeowner – which add to the value of any home.

Varieties of organic felt-based shingles are available with up to 40-year warranties. Some brands of aluminum or
steel shingles have a 40-year limited warranty and in addition, come with a coating approved by HUD, which
allows the roof to be used for collecting rainwater. Fiberboard shakes, a durable product, which can be nailed and
sawn, similar to wood shakes, come with a 30 to 50 year warranty.

Resources
See your local supplier.

5-110 Use 50-year warranted roofing material


3 POINTS

Using durable materials with long-lasting value helps prevent the need for replacement – an asset to the
homeowner – which add to the value of any home.

Some brands of aluminum or steel shingles have a 50-year limited warranty and in addition, come with a coating
approved by HUD, which allows the roof to be used for collecting rainwater. Fiberboard shakes, a durable product
that can be nailed and sawn similar to wood shakes, generally come with a 30 to 50 year warranty.

5-111 Use solar shingles


5 POINTS

Solar photovoltaic (PV) cells are now being incorporated into rooftop shingles. They are available in the same
patterns of traditional asphalt shingles, are exceptionally durable, and are wind and water tight. Using solar
shingles can lower electricity bills and increase home value.

Installation involves nailing PV shingles in place on roof decking over 30 lb. felt sheeting.

Resources
• OkSolar. 347-624-5693. www.oksolar.com/roof/. Online solar materials information and product website.
• U.S. Department of Energy Building Toolbox.
www.eere.energy.gov/buildings/info/components/envelope/roofing/solar.html. Energy efficiency and
renewable energy website. Includes specifics on solar shingles.
• Solar Components Corporation. 121 Valley Street, Manchester, NH 03103. 603-668-8186. www.solar-
components.com/pvshingl.htm. Sells solar roofing components.

5-112 Install a metal, concrete, slate, tile, or clay roof


8 POINTS

173
Metal roofs are made of recycled material and are 100% recyclable at the end of their lifecycle. They come with
warranties ranging from 30 to 50 years compared to 15 to 20 year life expectancies of asphalt shingles. Metal roofs
will not decompose under sun exposure, are noncombustible, can fit over existing roofing materials, are less than
1/3 the weight of asphalt and can withstand winds up to 140 mph.

Metal is naturally heat and light reflective and can reduce energy costs by as much as 25%. Metal roofs are a
better choice for rain water collection for irrigation, see Action item 2-68, Install Rainwater Collection System
(Cistern) for Reuse.

Resources
• Expert Village. http://homegarden.expertvillage.com/experts/metal-roofing-advantages.htm. Article
discussing the advantages of metal roofing.
• Englert. 1200 Amboy Ave., Perth Amboy, New Jersey 08861. 732-826-8614. www.englertinc.com/roofing-
whymetal.aspx?Page=1. Website discusses advantages of commercial and residential metal roofing.
• Mueller, Inc. 1915 Hutchins Ave., Ballinger, TX 76821. 877-268-3553.
www.muellerinc.com/roofing/benefits.php. Offers metal roofing products and technical information.

5-113 Install self-adhering underlayment on eves, valleys & penetrations


3 POINTS

5-114 Install self-adhering underlayment on entire roof


3 POINTS

Insulation

5-115 All insulation to have a minimum of 40% recycled-content


2 POINTS

There are several commonly available types of recycled content insulation:

• Cellulose insulation is made from 100% post-consumer recycled newspapers or telephone books. The
insulation can be dry-blown or poured loose-fill into enclosed cavities, but is most commonly wet-sprayed.
• Several brands of fiberglass insulation batts are manufactured using recycled glass, including
post-consumer glass collected in curbside recycling programs.
• Mineral wool insulation is another option and is available in loose-fill or batts. It has, on average, 75%
post-industrial recycled-content.
• Cotton insulation contains up to 85% post-industrial recycled fibers, such as blue jean material. It contains
no VOCs, and no chemical irritants. Cotton insulation is Class-A fire rated, rot, and pest proof.

Resources
Ask your supplier or installer about locally available options. The Cellulose Manufacturers Association in Dayton,
Ohio is an additional resource for product information: 888-881-2462 or www.cellulose.org.

Regional retailer of recycled cotton insulation:

174
• Environmental Home Center, 4121 1st Ave. S., Seattle. 206-682-7332, 800-281-9785, or
www.environmentalhomecenter.com. Offers Ultra Touch recycled cotton insulation in R13, R19 and R21.
Regional manufacturers of recycled-content cellulose insulation include:

• Thermaguard, Spokane, WA. 509-535-4500.


• Hamilton Manufacturing, Twin Falls, ID. 208-733-9689.
• Greenstone, Portland, OR. 503-286-9987.
Insulation products with recycled-content fiberglass or mineral wool include:

• GoldLine fiberglass insulation manufactured and distributed by Johns Mansville International, Denver, CO.
800-644-4013. Contains 25% recycled glass, including 18% post-consumer remelted bottle glass. (They
also make formaldehyde –free insulation see Action item 4-29, Use urea formaldehyde-free insulation or
GreenGuard Certified product.
• Thermafiber loose-fill mineral fiber made with rock wool, manufactured by USG Interiors, Tacoma: 253-
627-0379.

5-116 Use environmentally friendly foam building products (formaldehyde-free, CFC-


free, HCFC-free)
3 POINTS

Building an environmentally friendly home means eliminating the use of foam building materials that are
manufactured using chlorofluorocarbons (CFCs) or hydrochlorofluorocarbons (HCFCs).

CFCs are known to contribute significantly to ozone depletion and global warming, two of our most serious
environmental concerns. HCFCs are considerably less damaging than CFCs, but should also be avoided if at all
possible. In addition, avoid products that include formaldehyde, because indoor formaldehyde is gaining
recognition as a severe health hazard causing reactions ranging from flu-like symptoms to death in individuals
that become sensitized through exposure.

Options to consider include:

• Beadboard or EPS (expanded polystyrene) rigid foam insulation can be used for interior or below grade
uses. However, it doesn’t insulate as well (R-3.6 to R-4.4 per inch), but it is less damaging to the
environment because pentane is used in its production rather than HCFC.
• Polyurethane insulation (e.g. polyisocyanurate) made with pentane instead of HCFCs as the blowing agent
is now available. Unlike, EPS, however, there are few outlets for polyurethane foam as a recycled product.
• Blown-in cellulose (100% recycled newspaper content) or formaldehyde-free fiberglass.
• Soy, cotton, denim, or foam

Resources
• Atlas Roofing, Atlanta, GA. 800-388-6134 or www.atlasroofing.com. AC Ultra (ozone-safe
polyisocyanurate foam)
• Palmer Industries, Inc., Frederick, MD, 301-898-7848. Air Krete, inorganic, cementitious foam produced
from magnesium oxide. It’s nontoxic, inert, and non-combustible, and can be the insulation of choice for
people with high sensitivity to common household pollutants. Foamed in place in closed wall or masonry
block cavities, or behind mesh in open cavities. Lightweight and rigid, but friable foam.
• The Icynene Insulation System. A plastic, formaldehyde-free, foam insulation material similar in chemical
composition to the material used in pillows and mattresses. It is created on the jobsite by mixing two
liquid components that can be either sprayed or injected into the cavity. It contains no ozone-destroying

175
gas. Locally provided and installed by Progressive Insulation Company, Doug Utt, V.P., 2161 N Northlake
Wy, Seattle, WA 98103. 206-547-8706, e-mail: progsyst@aol.com, or website: www.asg1.com/progressive
• Insealation, Icynene, Inc., Mississauga, Ontario, Canada, 800-758-7325. A modified urethane spray-in-place
insulation that uses MDI but is water-blown rather than CFC-blown. Foamed into wall cavities like
polyurethane.
• AFM Corporation, Excelsior, MN, 800-255-0176. Perform Guard EPS, pentane is generally used in the
manufacture of this rigid foam insulation. A low-pentane formulation is used by AFM, the largest
expanded polystyrene (EPS or beadboard) producer, and several EPS manufacturers recover 95% of the
pentane used in production. Multiple suppliers.
• Foam Tech Inc., North Thetford, VT, 802-333-4333. Polyurethane SuperGreen uses a less ozone-depleting
HFC in its insulation, which is foamed into wall cavities. (The product costs slightly more than conventional
polyurethane.)
• C.P. Chemical Company, White Plains, NY. 914-428-2517. Tri-Polymer Foam, Phenolic foam with good fire
resistance foamed into primarily masonry block walls. Shrinkage over time reduces thermal performance.
For more information about insulation products, see:

• Cellulose Insulation Manufacturers Association, Dayton, OH. 888-881-2462 or www.cellulose.org.


• Expanded Polystyrene (EPS) Molder’s Association, Glenview IL. 800-607-3772 or www.epsmolders.org.
• “Insulation Materials: Environmental Comparisons,” Environmental Building News, Jan/Feb 1995.
Brattleboro, VT, 1999. 802-257-7300 or www.buildinggreen.com.

Other Exterior

5-117 Use reclaimed or salvaged material for landscaping walls


2 POINTS

Using discarded stone, brick, masonry, or wood materials to construct the landscaping walls not only saves
resources, but also can provide a unique appearance to match the style of the home.

Resources
See your local supplier of brick masonry for broken or reclaimed materials. Also, look at jobsites for discards.

5-118 Use lumber that is third-party certified sustainably harvested wood that meets
the Tier 1 requirements outlined in the handbook for decking and porches
3 POINTS

Select wood from certified or sustainable sources. Although there may be a slight cost premium associated with
this choice, it allows you to contribute to a sustainable enterprise and ensure protection of endangered hardwood
forests.

To receive credit for this Action item, the wood selected for the project must meet Certified Wood Products Tier 1
Requirements listed under Design and Material Selection, Wood Certification Guideline for Section Five. (See Table
5-1, at the beginning of the Design and Material Selection section.)

Currently, only the Forest Stewardship Council (FSC), a voluntary, market-based, certification organization, meets
Tier 1 requirements. It is one of few programs that require a chain of custody for certification. FSC sets standards
for sustainable forestry practices and depends on independent companies for third-party certification of
forestlands. It evaluates and monitors certifiers to ensure public credibility.

176
Resources
Ask your local supplier

See Resources listed for 5-45, Use Dimensional Lumber that is Third-Party Certified Sustainably Harvested Wood
that Meets the Tier 1 Requirements Outlined in the Handbook, 50% Minimum

5-119 Use 100% recycled-content plastic or wood polymer lumber for decks and
porches, or third party certified wood products
3 POINTS

There are many manufacturers of plastic lumber nationwide. Recycled plastic lumber or plastic/wood composite
lumber provide durable alternatives to solid wood for exterior applications such as fences, benches, decking,
docks, retaining walls, picnic tables, and landscape borders. Due to its weather- and insect-resistant nature,
plastic lumber can readily substitute for treated wood in non-structural applications. Plastic lumber is also rot and
corrosion-proof, and will not crack, splinter, or chip. It has a long life expectancy in exposed, sub-grade or marine
applications, and does not leach chemicals into ground or surface water or soil as treated wood can.

Plastic lumber resists vandalism and does not require painting. It is available in a variety of colors, including white,
although many companies have a standard color of either brown or black.

These products can be nailed, screwed, sanded, glued, or turned on a lathe with standard woodworking tools. One
challenging aspect of working with plastic lumber is its high expansion coefficient, which must be considered
during installation. Expansion issue is not a problem for wood polymers lumber product. Check with the
manufacturer regarding structural support specifications.

5-120 Use no-pressure treated lumber


4 POINTS

Naturally rot-resistant wood species are an option. Choose materials from certified, well-managed forests, see
Action item 5-45, Use Dimensional Lumber that is Third--Party Certified Sustainably Harvested Wood with an
Independently Audited Chain of Custody, 50% Minimum.

Recycled Plastic lumber is an alternative for some applications, 100% and plastic/wood composites are acceptable
for this credit.

Resources
• Fine Homebuilding Magazine. www.taunton.com/finehomebuilding/pages/h00127.asp. Article on
alternatives to pressure-treated lumber.

5-121 Use low-toxic pressure-treated wood


1 POINT

There are several types of low-toxic pressure treated wood products available, which, while providing the same
quality characteristics, represent minimized health risks or disposal dilemmas because of the different chemicals
used in their manufacture. When treated wood must be used, select one of the newer, copper-based products,
such as ACQ (Ammoniacal Copper Quaternary) , CBA (Copper Boron Azole), or a Borate based preservative.

ACQ preservative may be preferred where long-term weather resistance is required in addition to protection from
termites and other pests. (PLEASE NOTE: ACQ treatment is corrosive to some fixing materials. Ensure that
appropriate nails, screws and other hardwear are used with ACQ treated lumber; stainless steel screws are
recommended).

177
CBA is sold under the trade name Wolmanized Natural Select. Provides long-term resistance to termites and
fungal decay in ground contact and aboveground applications. Also can be used in fresh-, but not saltwater
applications.

Borate preservatives (such as Hi-Bor) are much less toxic than CCA, but will leach out of wood in wet conditions.
They are effective for treatment against termites when wood will not be exposed to weather.

As the industry transitions to alternatives, there may be price fluctuations. Initially, alternative products may cost
more than CCA-treated products, but some suppliers, in anticipation of the phase-out, are offering ACQ and CBA
products at competitive prices.

Naturally rot-resistant species, such as cedar and redwood, are an option, especially if any are available from
certified, well-managed forests. Recycled Plastic lumber and wood polymer lumber are other alternatives that are
cost-effective, durable, and can be used in low-load structural applications, including decks and docks, playground
equipment, benches, and tables.

What happened to CCA? In the past, the majority was treated using chromated copper arsenate (CCA), an
inorganic, waterborne preservative. Some of the chemicals used in this treatment process, however, pose a
certain health risk. There are health risk concerns about prolonged exposure after installation due to splinters or
wet wood creating a route for skin absorption. Another major concern is the resulting disposal problem it creates.
CCA treated wood is not recommended for burn facilities, so therefore, it becomes a landfill waste problem.

Since January 2004, the Environmental Protection Agency has banned the use of CCA treated dimensional lumber
in any residential applications. CCA-treated lumber is still available for nonresidential applications. To obtain
points for this Action item, you must select a product that does not contain CCA.

5-122 B20 biodiesel or better equipment


5 POINTS FOR 100% EXCAVATION EQUIPMENT ON BIODIESEL
1 POINT FOR EACH ADDITIONAL BIODIESEL VEHICLE FREQUENTLY ON SITE, 3 POINTS MAXIMUM

TO RECEIVE CREDIT FOR THIS ACTION ITEM THE FUEL MUST CONTAIN A MINIMUM OF 20% OR BETTER OF
BIODIESEL.

Biodiesel is a renewable fuel made from a mixture of alcohol and vegetable or animal oils. Incorporating biodiesel
into the fuel mix reduces particulate matter and carbon monoxide emitted from the engine. Biodiesel reduces the
amount of petroleum, a non-renewable fuel, thereby reducing the risk of harming sensitive environments during
extraction and transportation, and sends less particulate matter into the atmosphere.

Biodiesel does not require major engine modifications. This makes it the least-costly option when converting to
more energy efficient and less air polluting vehicles and machinery

Resources
• The Official Site of the National Biodiesel Board. www.biodiesel.org/resources/faqs/. General and technical
resource for Biodiesel and related products.

Recycling

5-123 Provide built-in kitchen or utility room recycling center


3 POINTS

One way to encourage recycling is to build a space for recycling containers in or near the kitchen, where 80% of a
home’s waste is generated.

178
Most millwork manufacturers now design cabinetry lines with storage areas geared to hold recycling bins. For new
cabinetry that includes factory installed pull-out bins, the estimated cost range is $30 to $40 per linear foot. There
may be additional costs associated with extra floor space, if required. Installing bins in existing base cabinets or
closets can be done fairly inexpensively.

Resources
The Green House, an “environmentally friendly home” exhibited annually at the Puyallup Fair, has demonstrated
several options, including:

• In-wall recycling system, LHRS (Leland Home Recycling Systems), 528 N. Bozeman, Bozeman, MT 59715.
406-587-0011.
• Under-counter recycling system, Feeney (by Feeney Manufacturing Co.) or Rev-a-Shelf; both are available
from E.B. Bradley Co., 3314 S. 116th St, Seattle, WA 98168. 206-248-5250.
Some other currently available options include:

• Blanco Box System, Blanco America, Inc., Cinnaminson, NJ, 800-451-5782, fax: 800-213-1963 or
www.blanco-america.com. The Blanco Box System uses plastic boxes on metal tracks below the kitchen
sink to store and aid in sorting of household recyclables.
• Recycling Receptacles, Doty and Sons Concrete Products, Inc., Sycamore, IL, 800-233-3907,
www.dotyconcrete.com, Doty and Sons Concrete Products uses recycled plastic lumber in its precast
concrete recycling and waste receptacles.
• The Fibrex Group, Inc., Chesapeake, VA, 800-346-4458 or www.fibrexgroup.com, Supplies recycling and
trash receptacles in many style and sizes including used motor oil collection containers and curbside
recycling collection bins. Many of these products are made of recycled-content plastics.

5-124 Provide garage sorting bins for recyclable materials


1 POINT

Most communities in Whatcom County offer town- or city-sponsored recycling collection programs. Some the
programs provide two or more collection bins for pre-sorted recyclables, and some programs provide one or two
bins for mixed recyclables. Check with your municipality to see whether the bins offered by the program are
suitable to meet the daily collection needs of the family in the home. As an added service to your clients who
pre-sort, you can offer additional bins for the garage to make the daily collection of recyclable materials more
convenient, allowing municipal containers to remain outside for weekly or bi-weekly collection.

Universal Design

5-125 Stepless front entry


2 POINTS

Promotes social sustainability by allowing homeowners to live in their home and communities longer and it
encourages visitability by a broader ranges of friends and family who might otherwise not be “able” to visit your
home.

Improves resale value and marketability (i.e., economic sustainability), as your home will be considered for
purchase by a broader population that is only getting bigger by the day (e.g. Boomers).

Promotes environmental sustainability and the design will never need to be changed to accommodate lifecycle
changes by current, temporary or future occupants of the home.

179
5-126 Stepless other entry (rear or side door, door from garage)
1 POINT

Stepless (Other/Alternate) Entry (e.g. rear, garage or side door)

5-127 Hard-surface stepless grade changes at exterior to allow access to essential


maintenance locations, like garbage cans, etc.
1 POINT

Promotes social sustainability by encouraging visitability by a broader range of friends and family participating in
your hosted outdoor events (e.g. BBQ) that might otherwise not be “able” to navigate your outdoor living spaces.

Promotes healthier lifestyles, by extending the years that people continue to remain active and busy nurturing
their yards, gardens, and socializing with family and friends in their lifespan designed outdoor spaces.

Promotes smarter and more functional outdoor spaces that better accommodate the many things on wheels that
are found in most of our homes, such as:

• Shop Vac
• BBQ
• Lawnmower
• Generator
• Wheelbarrow
• Furniture dolly
• Garbage bin
• Recycle bin
• Yard waste bin
• Yard cart
• Pressure washer
• Strollers
• Bikes, trikes, wagon, scooter
• Luggag
• Wheelchair
• Other

5-128 Install exterior accessible hard-surface gathering area


1 POINT
REQUIRES ACTION ITEM 128, HARD-SURFACE STEPLESS GRADE CHANGES AT EXTERIOR TO ALLOW ACCESS
TO ESSENTIAL MAINTENANCE LOCATIONS, LIKE GARBAGE CANS, ETC.

Landscape hard-surface gathering areas (e.g., pavered at-grade patio areas) should be considered as an upgrade
and compliment to stepless grade changes throughout and considered for additional earned checklist point value.

180
5-129 Provide accessible guest bathroom on main floor of home
2 POINTS

REQUIRES STEPLESS ACCESS TO HOUSE, EITHER 5-125 OR 5-126

Promotes social sustainability by encouraging visitability by a broader range of friends and family who might
otherwise not be “able” to visit your home.

Improves resale value and marketability (i.e., economic sustainability), as your home will be considered for
purchase by a broader population that may consider visitability as a “value-added” feature that will serve to
strengthen the longevity of their social circles of both friends and family.

Promotes environmental sustainability and the design will never need to be changed to accommodate lifecycle
changes by current, temporary or future occupants of the home.

5-130 Accessible bathroom with curbless shower, (grab-bar blocking required in all
bathrooms)
3 POINTS

Promotes social sustainability by allowing homeowners to live in their home and communities longer.

Improves resale value and marketability (i.e., economic sustainability), as your home will be considered for
purchase by a broader population that is only getting bigger by the day (e.g. Boomers).

Promotes environmental sustainability and the design will never need to be changed to accommodate lifecycle
changes by current, temporary or future occupants of the home.

5-131 Locate closets or other spaces directly above each other on all floors that can be
used for future elevator installation.
3 POINTS STACKING CLOSETS ENGINEERED TO RECEIVE A FUTURE ELEVATOR
5 POINTS IF ADEQUATE ELECTRICAL CIRCUIT IS PROVIDED IN ATTIC

Promotes social sustainability by allowing homeowners to live in their home and communities longer.

Improves resale value and marketability (i.e., economic sustainability), as your home will be considered for
purchase by a broader population that is only getting bigger by the day (e.g. Boomers).

Promotes environmental sustainability and the design will never need to be SIGNIFICANTLY changed to
accommodate lifecycle changes by current or future occupants of the home.

Requires that the rooms have been sized according to manufacturers data to assure that a residential elevator will
fit in the space designated.

Requires a concrete slab, with a drain, at the bottom.

Requires 38” rough-opening door framing width, door openings lined up from floor to floor.

5-132 Minimum door width 2'-10" for all rooms requiring entry (small closets excepted)
3 POINTS

Rooms not requiring entry by homeowners are exempted from this requirement

Promotes social sustainability by allowing homeowners to live in their home and communities longer.
181
Rooms requiring entry means any room that a person would need to enter in order to use the room. Only small,
shallow closets, where reach-in access is the normal way to use the room, and special equipment rooms for
furnaces or similar equipment normally only accessed by qualified technicians would be exempted from this
requirement.

Improves resale value and marketability (i.e., economic sustainability), as your home will be considered for
purchase by a broader population that is only getting bigger by the day (e.g. Boomers).

Promotes environmental sustainability and the design will never need to be changed to accommodate lifecycle
changes by current, temporary or future occupants of the home.

5-133 Install smart technology (e.g. electronic blinds, programmed environmental


controls, etc.)
1 POINT PER INSTALLED ITEM
3 POINTS MAXIMUM

(e.g., electronic blinds & programmed environmental controls, one point for each installed system up to 3)

Promotes social sustainability by allowing homeowners to live in their home and communities longer.

Improves resale value and marketability (i.e., economic sustainability), as your home will be considered for
purchase by a broader population that is only getting bigger by the day (e.g. Boomers).

Promotes environmental sustainability and the design will never need to be changed to accommodate lifecycle
changes by current, temporary or future occupants of the home.

5-134 Install cabinets with removable or slide-away lower doors for roll-up access to
kitchen sink, upper cabinets that lower to counter top height for access, etc.
1 POINT PER FEATURE
3 POINTS MAXIMUM

Customized cabinetry with special features such as: upper cabinets that lower to counter level for access to a
wheelchair user or person of short stature, or sink-base doors that slide away with no cabinet bottom shelf for roll-
up access to the kitchen sink.

5-135 Special work and forethought, innovative universal design features, see
Homebuilder Guide for more information.
1 POINT PER UNIVERSAL DESIGN FEATURE
3 POINT MAXIMUM

Example #1: An open “header-free” seamless passage between a Master Bedroom and its privately adjoining
bathroom with curbless shower would accommodate a future continuous overhead track ceiling-mount lift
system). This pre-planning would also want to include associated backing in the ceiling framing.

Example #2: Bathroom vanity with detached pull-away base cabinet assembly, making ready for a future
wheelchair accessible self-supporting sink vanity counter. The pre-planned casework unit would require NO future
modifications including the concealed floor finishes and base that would be instantly exposed and ready “as-is.”

Promotes social sustainability by allowing homeowners to live in their home and communities longer.

Improves resale value and marketability (i.e., economic sustainability), as your home will be considered for
purchase by a broader population that is only getting bigger by the day (e.g. Boomers).

182
Promotes environmental sustainability and the design will never need to be changed to accommodate lifecycle
changes by current, temporary or future occupants of the home.

Extra Credit for Materials Efficiency

5-136 Extra credit for innovation in Materials Efficiency


1-10 POINTS

You may submit a materials efficiency strategy or system, not specifically called out in this Section, for
consideration for an Extra Credit for Innovation. All extra credits will be approved by the Program Director. If
approved, add up to 10 points to your Section total.

183
Section 6 OPERATION, MAINTENANCE & HOMEOWNER EDUCATION
The purpose of this section is to promote responsible homeowner operation and maintenance throughout the life
of the home, by equipping your clients to continue the good work you have begun. Whether your client initiated
using green features, or it is part of your standard business practices, it is important to educate your clients in
using and maintaining the products, equipment, or other features installed as part of the project. Studies show
that most individuals care about the environment and are willing to take certain actions to protect it, as long as
those actions are not expensive, time-consuming, or inconvenient. You can take steps to provide useful
information and practical products to help your clients maintain their new green home.

Your Homeowner’s Kit may simply include the required information or it may also include environmentally
friendly “gifts.” We encourage you to be creative with this Action item. In addition to the kit’s educational value,
you’ll benefit from showing your client that you care. It will reinforce your reputation as a “Green Builder” serving
the community.

Personalize the Homeowner’s Kit by labeling it with the owner’s name and address and be sure to include any
specific information requested by owner. Obtain owner’s signature on a “sign-off” sheet indicating information in
the kit has been received. Let owner know the information should be read carefully in order to optimize the
environmentally friendly features you have taken extra effort to incorporate.

Information on:

• Local mass transit opportunities


• Environmentally friendly landscaping operations and maintenance practices
• Pervious surfacing products for outdoor projects / surfaces (to avoid increasing stormwater runoff)
• Pest resistant and disease resistant plants, including native plants, provide a list
• Optimally operating and maintaining irrigation equipment
• Site critical areas, such as buffer zones, that should be protected (if applicable)
• Protecting and caring for valuable site features, including mature trees if applicable (Encourage protection
and retention of existing arboreal overstory where possible)
• Integrated pest management as an alternative to chemical landscape pest treatments
• Operating and maintaining water-using fixtures and equipment to avoid long-term leaks and optimize use
• Energy efficient appliances, including fact sheets, or a list of options (if appliances are not included)
• Energy-efficient lighting fixtures
• Operating and maintaining the home for good indoor air quality
Gifts could include:

• Non- or low-toxic cleaning supplies, such as environmentally friendly laundry or dish detergent, or paper
products with recycled-content
• Environmentally friendly furnace filter(s)
• Native species flower seeds
• Environmentally friendly gardening supplies.
Some useful resources for homeowners are:

• Consumer Guide to Home Energy Savings, 7th Edition, by Alex Wilson, Jennifer Thorne, and John Morrill.
Updated annually and has good product recommendations. Available in bookstores, from the American
Council for an Energy-Efficient Economy (ACEEE), Washington, DC, www.aceee.org.
• Home Water-Saving Methods, by Ronald E. Hermanson, Publication #EB0732, WSU Cooperative Extension.
Page 184
• Consumer Reports, August 1998. A thorough and informative report for consumers on buying carpets,
including a section on carpet and indoor air quality. Copies of the issue ($5) can be obtained by writing:
Back Issue Dept., Consumer Reports, PO Box 53016, Boulder, CO www.consumerreports.com.
• LightWise Compact Fluorescent Bulbs: More Value for Your Energy Dollar, Puget Sound Energy publication.
Includes a list of stores offering compact fluorescents at discount prices. Puget Sound Energy.
• Indoor Air Quality and Your Home and Homeowner’s Guide to Ventilation, from New York State Energy
Research and Development Authority (NYSERDA), www.nyserda.org.
• How to be a Salmon-Friendly Gardener, a publication of Seattle Public Utilities. Also online at
www.ci.Seattle.wa.us/util/RESCONS/plantNaturally/salmonfriendly.htm.
• The Washington chapter of the American Lung Association (ALA), for questions relating to ventilation,
insulation, or pollutant source control, www.alaw.org.
• WSU Cooperative Extension Energy Program can provide you with consumer fact sheets on energy-
efficient appliances: www.energy.wsu.edu.

6-1 A building owners’ manual is provided:


3 POINTS FOR 4 ITEMS
5 POINTS FOR ALL ITEMS

• Information on local recycling programs


• Information about available local utility programs that purchase a portion of energy from renewable
energy providers
• Explanation of the benefits of using energy efficient lighting systems (e.g., compact fluorescent light
bulbs, light emitting diode (LED) in high usage areas
• A list of practices to conserve water and energy
• Local public transportation options
• List of common hazardous materials often used around the building and instructions for proper handling
and disposal of these materials
• Information about organic pest control, fertilizers, de-icers, and cleaning products
• Information about native landscape materials and/or those that have low-water requirements

6-2 Building owners/occupants are familiarized with the green building goals and
strategies implemented and the impacts of the occupants' practices on the costs
of operating the building. Training is provided on the equipment operation and
control systems
6 POINTS

6-3 A diagram showing the location of safety valves and controls for major building
systems
0.5 POINTS

Page 185
6-4 Where frost protected shallow foundations are used, notify owner of precautions,
including instructions not to remove or damage insulation when modifying
landscaping, to provide heat to the home as required by the irc/ibc, and to keep
base materials beneath and around the home free from moisture due to broken
water pipes or other water sources
0.5 POINTS

6-5 A list of local service providers that offer regularly scheduled service and
maintenance contracts to assure proper performance of equipment and the
structure (e.g., HVAC, water heating equipment, sealants, caulks, gutter and
downspout system, shower/tub surrounds, irrigation system.)
0.5 POINTS

6-6 a photo record of framing with utilities installed. photos taken prior to installing
insulation, clearly labeled, and included as part of the homeowner's binder
0.5 POINTS

6-7 Maintenance checklist


0.5 POINTS

6-8 Information about methods of maintaining the building's relative humidity in the
rate of 30-60%
0.5 POINTS

6-9 Instructions for maintaining gutters, downspouts, raingardens and other


infiltration devices and importance of diverting water at least five feet away from
foundation
0.5 POINTS

6-10 Instructions for inspecting the building for termite infestation


0.5 POINTS

Page 186
6-11 A narrative detailing the importance of maintenance and operation retaining the
attributes of a Built Green home
0.5 POINTS

6-12 Educate owners/tenants about fish-friendly moss control


1 POINT

Moss is a natural part of the Pacific Northwest. It thrives in lawns, on roofs, and in crevices in sidewalks and drives.
There are various chemical treatments available on the market for control of moss and other growth. However,
several have adverse environmental impacts. For this reason, homeowners (and builders) should avoid all zinc and
copper products including zinc sulfate, monohydrate, copper sulfate (also called blue stone), galvanized ridge
caps, copper flashing, and copper wires. In addition, homeowners should avoid the use of table salt to kill moss
and algae. It is corrosive to metal and is not very effective.

Instead, homeowners should remove moss from roofs and other areas using a stiff brush, broom, or power washer
for hard-to-reach areas. As a last result, moss can be killed by spraying it with hot water (use a utility or other sink
with hot water supply and connect a hose).

Provide information about environmentally friendly moss control to the homeowner as part of the Homeowners
Kits (see Action item 6-1, A building owners’ manual is provided).

Section 7 BUILT GREEN BRAND PROMOTION

7-1 Extra credit for innovation in marketing for Built Green brand
1-10 POINTS

FOR INCLUDING THE BUILT GREEN LOGO IN SHOWROOM OR WEBSITE 5 POINTS

FOR THE BUILT GREEN LOGO, ETC. … 10 POINTS

Page 187
APPENDIX
Contents:

• Housing Size Matrix


• Seasonal Land clearing Worksheet
• Energy Benchmarks to meet Built Green 3-Star, 4-Star and 5-Star Requirements
• Chart 3-A: Built Green Component Performance Method
• Chart 3-B: Built Green Prescriptive Scoring Method
• Built Green Job Site Recycling Plan
• Contractor’s Short Guide to Waste Prevention and Recycling

Page 188
Table 0-1 House Size Matrix

Bedrooms Multiplier min. points req in min. points req in


energy section** materials
section**
1 2 3 4 5 6
<500 <700 <900 <1300 <1900 <2400 1.20 N/A N/A
501- 800 701-1000 901-1200 1301-1750 1901-2350 2401-2700 1.15 N/A N/A
801-1200 1001-1400 1201-1800 1751-2350 2351-2950 2701-3500 1.10 N/A N/A
1201-1600 1401-1800 1801-2400 2351-3000 2951-3600 3501-4300 1.05 N/A N/A
1600 1800 2400 3000 3600 4300 1.00 0 0
SF

1601-1800 1801-2000 2401-2700 3001-3400 3601-4000 4301-4700 1.00 25* 25


1801-2000 2001-2200 2701-3000 3401-3800 4001-4400 4701-5100 1.00 35*+ 35+
2001-2200 2201-2400 3001-3300 3801-4200 4401-4800 5101-5500 1.00 45*+ 45+
>2200 >2400 >3300 >4200 >4800 >5500 1.00 55*+ 55+
= 2005 avg. home size in WA State

Page 189
SEASONAL LANDCLEARING WORKSHEET
Use this Checklist to evaluate the Erosion and Sediment Control measures needed for wet season
landclearing (October 1- April 30)

Date of Evaluation: __________________ Proposed Start Month for Project: ________________


Site/Lot#: ________________________Address: _______________________________

Total Points By Month (see thresholds below to determine which month to legally begin project)

TIME OF YEAR – Weighted by average monthly rainfall:


October POINTS 5 __________
November POINTS 20 __________
December, January, February, March POINTS 25 __________
April POINTS 10 __________

HYDROLOGIC SOIL GROUPS -


Group A: High Infiltration Rate POINTS 5
Group B: Moderate Infiltration Rate POINTS 10
Group C: Slow Infiltration Rate POINTS 15
Group D: Very Slow Infiltration Rate POINTS 20 ___________

SLOPE - Steepest portion of the footprint of the area proposed for clearing activity, prior to land disturbance:
0% to 2% slope POINTS 0
3% to 8% slope POINTS 5
9% to 14% slope ________% POINTS 10
15% to 34% slope POINTS 20
Over 35% slope POINTS 30 ___________

CLEARING ACTIVITY SIZE -


500 to 5,000 square ft. POINTS 5
5,001 square ft. to .99 acre POINTS 10
1 to 5 acres POINTS 30
Over 5 acres POINTS 50 ___________

PROXIMITY TO WETLAND OR WATER BODY- Cumulative (20’ wide driveway across drainage ditch =0):
Less than 10 feet from drainage ditch or POINTS 20
storm drain, other than a driveway crossing.
Less than 100 feet from a wetland or stream POINTS 20
(subject to the Critical Area Ordinance)
Less than 200 feet from a lake or marine
shoreline POINTS 20 ___________

Evaluator Name/Contact__________________________ Subtotal:

ACTION:
 40 OR LESS: Standard Erosion and Sediment Control BMPs

 GREATER THAN 40 AND LESS THAN 75: Winter Clearing Plan developed, applied and
monitored by a certified ESC installer. Current certification and contact information must
be included with BuiltGreen submittal.

 75 0R GREATER: Do not clear site during wet season start (October 1- April 30).
Table 0-2 Energy Benchmarks to meet Built Green 3-Star, 4-Star
and 5-Star Requirements
• 3-Star- Independently verified to be at least 15% more efficient than Washington State Energy Code

• 4-Star- Independently verified to be at least 20% more efficient than Washington State Energy Code

• 5-Star- Independently verified to be at least 30% more efficient than Washington State Energy Code

Certification Path: Energy Star certification

Modeling Path: Demonstrate30% (3-Star) 35%(4-Star) or 45%(5-Star) improved efficiency over 2004
International Energy Code via UA Calculator.

Approved Modeling Software:

• WSU UA Alternative Worksheet

• REM Rate

• Energy Gauge

• TREAT

• ResCheck

• Other software may be allowed upon prior approval


Chart 3-A. BUILT GREEN Component Performance Method
For buildings that qualify for the Washington State Energy Code using the component trade-off method.
Improvement represents a reduction in heat loss compared to the code reference house. (Total UA of the proposed
building / UA of the WSEC code reference building. Based on minimum performance to qualify the home, using the
WSU UA Alternative Worksheet or equivalent.) Score 1 point for each percentage reduction in energy use.

_____________________ Total heat loss reduction for home.

To document what you have done for the client, please record U values below.

Building Component Upgrade

Window Upgrade U-Value to ________________________________

Skylight / Vault Upgrade U-Value to ________________________________

Floor Over Crawl Upgrade R-Value to ________________________________

Wall Upgrade R-Value to ________________________________

Attic Upgrade R-Value to ________________________________

Vault Upgrade R-Value to ________________________________

Slab on Grade Upgrade R-Value to ________________________________

Below Grade Slab Upgrade R-Value to ________________________________

Below Grade Wall Upgrade R-Value to ________________________________

Other Upgrade U- or R-Value to ____________________________

Improve heating
(AFUE or HSPF) _________________________________________________
Chart 3-B. BUILT GREEN Prescriptive Scoring Method; Upgrades
for all Fuel Types (See Note 1)
.

Envelope 2012 WSEC Code Baseline/ Target H/L U-Value Points Points
Component Improvement Description, Level Ratio Allowed Taken

Doors 0.045 U-.30 0


1-Star U-.28 0
2-Star U-.27 0
3-Star U-.25 0.5
4-Star U-.24 1
5-Star U-.21 1.5
Skylights* 2gl, low-e temp/lam 0.015 U-.50 0
*If no skylights, take 1 point 1-Star U-.47 0
**If more than 1 5-star level 2-Star U-.45 0
skylight, take 1 point 3-Star U-.42 0
4-Star U-.40 0
5-Star** U-.35 0.5
Windows 2-gl, low-e/argon/ss 0.33 U.30 0
1-Star U-.28 2
2-Star U-.27 4
3-Star U-.25 6
4-Star U-.24 7
5-Star U-.21 10

Ceiling/Roof R-38 (raised heel truss) 0.098 U-.026 0


R-49 (standard heel truss) U-.027 0
R-60 (standard heel truss) 1-Star U-.025 0.5
R-49 w/R10 foam sheathing 2-Star U-.024 1
R-49 w/R15 foam sheathing 3-Star U-.023 1.5
11.25" core supported SIPS 4-Star U-.022 2

R-49 (raised heel truss) 5-Star U-.020 3


Walls R-21 Std. cavity only 0.398 U-.056 0
(above grade)
R-21 Adv. Framing 1-Star U-.053 2

R-23 Adv. Framing 2-Star U-.050 4


5.5" core SIPS (EPS) 3-Star U-.048 6
3.5" core SIPS (Polyurethane) 4-Star U-.045 8
R-21 Adv. + R-5 Foam 5-Star U-.040 11.5
Floor (over crawl) 0.11
R-30 vented joist U-.029 0
9.25" core SIPS 1-Star U-.028 0.5
R-25 joist w/R10 foam 2-Star U-.026 1
R-38 vented joist 3-Star U-.025 1.5
11.25" core SIPS 4-Star U-.023 2
R-49 vented joist 5-Star U-.020 3.5

Floor (slab-on- R-10 2' vertical 0.11 F-0.540 0


grade)
R-10 fully insulated/heated F-0.550 0
R-15 2' vertical 1-Star F-0.522 0.5
R-10 4' vertical 2-Star F-0.495 1
R-5 fully insulated 3-Star F-0.467 1.5
R-10 2', R-5 center 4-Star F-0.440 2
R-15 fully insulated 4-Star F-0.440 2
R-10 fully insulated 5-Star F-0.385 3.5
R-20 fully insulated/heated 5-Star F-0.330 3.5
Below Grade R-10 exterior or R-21 interior 0.165 Wall U-.042, 0
Slabs & Walls w/thermal break Slab F-0.570
R-5 foam w/R15 interior 1-Star U-.040/F-0.54 1

R-10 foam w/R13 interior 2-Star U-.038/F-0.51 2


R-15 exterior 3-Star U-.036/F-0.48 3
R-10 foam w/R-15 interior 4-Star U-.034/F-.46 4
R-20 exterior 5-Star U-.029/F-0.40 6

Chart 3-B Notes:


1. The prescriptive path is the simplest, but also the least flexible, method for estimating heat loss reduction. It
does not provide credit for reductions in glazing areas. You may (or may not) have a higher score if you use the
component performance method (Chart 3-A).
2. U-Value: Calculated U-value for the described building component. If you select a component that is not
described in the text, use the Reference U-value of the product to score it.
3. Heat Loss Reduction: Estimated reduction in total UA of the structure. Based on two prototypical structures.
Note: This is NOT equivalent to energy savings. WATTSUN can provide you with estimated fuel savings.
4. Assigned Point Value: based on 1 point for each percentage point in heat loss reduction.
5. Score: Record your score based on assigned point values for the measures you implement. For example, if
you use windows with U equal to 0.50, the estimated heat loss reduction is 10%, so your score for this item is 10
points. If you use more than one component per category (wall, attic, etc.), average the scores for all components.
Your total score is the sum of all scores for individual items. Max. score is 32 points.
6. Code Baseline: WSEC target Prescriptive Path for “other fuels.” Minimum requirements must be met for all
components.
Identifies those products that provide wood savings as well as energy savings.
BUILT GREEN Jobsite Recycling Plan
Recyclable Materials

What material Condition of How will it be Who will haul Where will it
will you material* handled on site? it? be taken?
target?

 Wood

 Cardboard

 Ferrous
l
 Non-ferrous
metal

 Drywall

 Asphalt
Roofing
 Concrete /
Asphalt
Rubble

 Other

*Check with your recycler or hauler to see if any specifications or conditions exist regarding the material
being recycled. Examples include size restrictions and non-acceptable materials (for example,
treatments, finishes, or fasteners).

Action items
 Complete this Jobsite Recycling Plan and post on site.
 Commit subcontractors to recycle in Subcontractor Agreement.
 Keep subcontractors and workers aware and informed of Recycling Program.
 Require individuals to properly sort recyclables and hold them responsible for mis-sorted loads.
 Track and promote recycling results.

Page 195
Contractors’ Waste Reduction Resource Sheet
Introduction
This short guide contains information condensed from the “Contractor’s Guide to Waste Prevention and Recycling.” If you
need more information on a given topic, you can find it there. The guide provides recycling and waste prevention how-to’s
for all builders, from handyman/remodelers to large commercial contractors, who want to save money. Both Counties and
several Cities can provide assistance on reducing, reusing and recycling construction wastes. Other resources are listed in
this guide under “Where to Get More Information.”

Preventing Waste in the First Place


Waste prevention is even more beneficial than recycling. Why? Activities that prevent the production of waste, such as
reusing building materials not only cuts garbage and recycling collection costs but also reduces materials expenses. Small
changes to building practices and extra attention to detail can add up to significant savings for the builder and the
environment.

• Set up central cutting areas for wood and other


Design To Prevent Waste materials. Make sure the crew uses all the reusable
pieces before cutting a new piece.
• Design with standard sizes for all building materials
• Reuse concrete forms on the job and on other jobs.
• Specify materials and assemblies that can be easily
Wood forms can frequently be used up to 15 times.
disassembled at the end of their useful life
Alternatively, use reusable metal or fiberglass forms.
• Choose durable interior finishes or materials that
• Practice material storage and handling procedures
can be easily removed and recycled when worn or
damaged that prevent loss from weather and other damage.
• Consider reusing materials (on-site) or installing
Purchase to Prevent Waste
salvaged materials from off-site sources.
• Consider the purchase of good-quality, previously
Construction Methods that Prevent Waste used items such as cabinets, doors, and equipment.
• For wood construction, use advanced framing • Re-evaluate estimating procedures to make sure the
techniques (e.g. 24” on center, and insulated correct amount of each material is delivered to the
headers), trusses for roof or floor framing, finger site.
jointed studs and trim, and engineered wood • Choose products that come with minimal or no
products. packaging.
• Consider using wood frame wall panels • Replace toxic materials with less toxic or non-toxic
prefabricated off site alternatives to reduce hazardous waste disposal
• For concrete construction, use precast concrete fees.
members. • Ask suppliers to deliver supplies using sturdy,
returnable pallets and containers. Have them pick
Prevent Waste On-Site up the empty containers when delivering new
supplies. Also, require suppliers to take back or buy-
back substandard, rejected, or unused items.

Page 196
Salvage and Reuse Of Building Materials
By reusing items on-site, donating and/or selling salvageable items, you can cut waste and reduce supply costs. If you are
using a demolition contractor, specify reuse and salvage in the contract. Deconstruction services are offered locally by
ReStore

• Before demolition/deconstruction, identify The following are just a few of the materials that can
potentially reusable or salvageable items. be salvaged, and donated or sold locally:
• Determine the savings and cost of reusing,
donating, and/or selling the salvageable items.
• Inform the demolition crew of the salvage Appliances Bathroom Fixtures
procedures and expectations. Careful removal of
Bricks Cabinets
these items is the key to their marketability.
Carpeting Dimensional Lumber
Other Reuse Options
Many companies have had success with less formal reuse Doors Ductwork
options. Consider the following ideas:
Flooring Insulation
• Advertise reusable items in the newspaper.
Lighting Fixtures Marble
• Conduct a “yard sale” on the job-site to sell reusable
items. Metal Framing Paneling
• Allow workers to remove wood or other salvageable
items for their own use. Pipes OSB &Plywood
• Set out “free wood” signs.
• Ask some subcontractors (such as electricians and Shelving Siding
pipe fitters) to reuse or recycle their own materials.
Tile Trim
Consider asking for or requiring documentation to
verify reuse or recycling.
Windows Wood Beams

Setting Up a Job-Site Recycling Program


Recycling construction materials helps save money by cutting disposal costs. It also reduces waste going to the landfill and
attracts clients who value environmental responsibility. Other benefits include a cleaner, safer site and improved
community relations. Follow these steps to set up a successful, cost-effective recycling program for your job-site.

• Determine when the project will generate each


Start Early waste.
Incorporating recycling up front will ensure that
Identify Recyclables and Research Recycling
opportunities are not missed and that the program is
successful. Options
• Landclearing debris, wood, drywall, concrete, rock,
Analyze Project Waste asphalt, brick, carpet and asphalt roofing and other
• Estimate the types and quantities (tons or cubic construction wastes may be recyclable in the Skagit
yards) of waste the project will generate. Include and Island Counties area. Consult Skagit and Skagit
demolition phase volumes County Solid Waste Divisions for more information.

Page 197
• Remember that chipping land clearing debris to use • Clearly designate the recycling bins. Post lists of
for mulch or erosion control, and grinding concrete what is and what is not recyclable.
and asphalt for fill are inexpensive, on-site recycling • Place garbage and recycling bins near each other,
options. and close to the point of waste generation but out of
• Decide whether to self-haul recyclables to the the traffic pattern.
recycling facility or to contract with a recycling
hauler. Communicate the Plan
• For recycling haulers, determine whether you will
It is important to educate everyone on the job-site about
co-mingle recyclables or source separate them for
the waste management program.
collection.
• Discuss waste handling requirements with crew and
Select the Recyclers subcontractors prior to beginning a project.
• Contact SICBA for referral to recycler(s) of the • Post easy to read signs and provide written
materials you will be generating on your site. information about the recycling program.

Determine the Savings Monitor the Program


• Compare the cost of normal construction waste An effective recycling program includes occasional
disposal practices with the cost of recycling to monitoring.
determine if recycling is feasible.
• Use the economics worksheets in the Appendix to • Check bins regularly for contamination.
determine potential costs and savings for recycling. • Periodically check the wastes in the garbage
dumpsters to see if recyclables are being thrown
Develop a Waste Management Plan away or if there are additional materials that could
be recycled.
A Waste Management Plan identifies materials to be
• Call the recycler before bins are full to arrange for
recycled on a project; including materials subcontractors pick up.
will be responsible for recycling. The plan outlines
recycling procedures, expectations, and results. Track Your Success
• Filling out the Recycling Checklist will give you a Tracking the quantities and cost savings of diverted
good start on the basics of a Waste Management materials is important for future estimating. It is also
Plan. required for BUILT GREEN certification.
• Once construction has started, keep the receipts
Set Up the Site from recycling and garbage disposal. Furnish
receipts to your company’s estimating department
Work with your recycler and crew to determine the most
for planning future waste management budgets.
effective way to set up the site for maximum recycling.
Some suggestions include the following:

Making Your Program Work


The small effort needed to prevent waste and recycle on a job-site usually pays off in disposal and supply cost savings.
Here are solutions to some of the challenges faced when developing and implementing a waste management plan.

• Designate a person to manage the details of activities. Be sure to provide recycling for the variety
creating and implementing the program. On of wastes the subs generate.
residential projects, this might be the contractor, • Alternatively, ask the subs to recycle their own
site supervisor, or crew chief. waste, but require written reports. Since many subs
• Require subs to use the recycling and disposal bins wastes are homogeneous, it is easy to separate the
on-site. This allows the most control of recycling wastes for recycling.
Space Constrained Sites
Promotion and Education
• Choose smaller bins and more frequent collection.
There are a variety of container sizes and service • Include waste handling requirements in all project
options available through recycling service documents. This makes it clear from the beginning
providers. that waste prevention and recycling is expected
• Use scrap lumber to divide one dumpster into from all crew members and subs.
separate compartments for storing recyclables and • Treat waste management like a safety program.
trash on-site instead of having multiple dumpsters. Integrate recycling training into the safety
• Use smaller containers that are collected at the end education, or design a separate recycling education
of the day and dumped into a larger container for program.
pick up. • Share the success. Let subcontractors and crew
• If self-hauling, build custom containers to fit the know how well they are doing by regularly posting
space requirements using scrap or damaged volumes of materials reused/recycled.
plywood, concrete forms, or barrier fencing.
Preventing Contamination of Recyclables
• Clearly designate the recycling bins. Post lists of
what is and what is not recyclable.
• Place recycling and trash bins near each other so
trash is not thrown in the recycling bin.
• Provide enough trash bins to collect unrecyclable
items. Have them emptied regularly so the overflow
does not end up in the recycling bin.
• Dump out contaminated loads and have the
subcontractors and/or crew pull out the
contaminants themselves. It takes some time, but
contamination probably won’t happen again.
• Place small recycling bins on the work floor and use
the crane or laborers to empty the bin on a regular
basis.
Using Recycled-content Building Materials
Many common building products like drywall and blown-in cellulose insulation have contained recycled materials for years. New
products utilizing recycled materials, such as carpet, concrete, and plastic lumber, are being developed every day.

How to Buy Recycled


• Obtain information on recycled products. Locally, there are several excellent free or low-cost resources available Refer to
“Where to Get More Information” for help.
• Consistently communicate your interest in recycled-content building materials in your specifications, policies and in your job-
site meetings.
• Contact manufacturers for product specifications and samples. Look for products with the highest post consumer content that
meets your strength and durability specifications.
• Look for recycled content products for your office or job shack. Copy paper, toner cartridges, and desk supplies are readily
available with recycled content.

Examples of Recycled-Content Building Products


BUILDING MATERIALS SITE WORK
Bathroom Partitions Asphalt
Benches Base Coarse
Bike Racks Building Blocks
Carpet/Carpet Pad Building Panels
Ceiling Tiles Compost
Cellulose Insulation Concrete
Copper Shingles Concrete Masonry Units
Counter Tops Fill Material
Ductwork Glassphalt
Exterior Sheathing Parking Stops
Fences/Posts Recycling Containers
Fiberboard
Fiberglass Insulation
Floor Joists
Flooring
Lumber
Pilings
Roof
Structural Steel
Wallboard
Where to Get More Information
Technical Assistance
• Other Washington State projects – call the Washington State Department of Ecology at (360) 407-6300 for referrals.
www.wa.gov/swfa/cdl/cdlframe.html

Reuse and Recycling Resources


• 1-800-RECYCLE, Washington State Department of Ecology’s statewide recycling services information hotline – call 1-800-
RECYCLE or visit their website at: www.1800recycle.wa.gov
Used Building Materials Suppliers Using Recycled-content Building Materials
• Reusable Building Materials Exchange – an interactive
• Recycled Content Building Materials Guide is available
web page for exchanging all types of used or surplus
on the internet at
building materials: www.rbme.com/wa/pierceco/
http://dnr.metrokc.gov/swd/bizprog/sus_build/RCBMG.
pdf

You might also like